Abstract
Aims/Introduction
Compared with glargine 100 U/mL (Gla100), glargine 300 U/mL (Gla300) and degludec (Deg) – the ultralong‐acting insulins – reportedly have more stable effects and reduce the risk of hypoglycemia. Currently, they are considered to be the most useful basal insulins. The present study aimed to compare the efficacy and safety of Gla300 and Deg on glycemic control using continuous glucose monitoring.
Materials and Methods
In this single‐center, open‐label, parallel‐group, two‐period, cross‐over study, 30 patients with type 2 diabetes were randomized to once‐daily Gla300 followed by Deg with the same units (n = 15) or vice versa (n = 15). The primary end‐points of this study were the mean percentage of time within the target glucose range of 70–180 mg/dL as efficacy and hypoglycemia of <70 mg/dL as safety indicators, as measured using continuous glucose monitoring during each treatment period.
Results
The mean percentage of time within the target glucose range was not different between Gla300 and Deg (77.8 ± 19.2 vs 76.9 ± 18.3%, P = 0.848). However, the mean percentage of time of hypoglycemia with Gla300 was significantly lower than that of Deg (1.3 ± 2.7 vs 5.5 ± 6.4%, P = 0.002). In the secondary safety end‐points, the mean percentage of time of severe hypoglycemia (<54 mg/dL) or nocturnal hypoglycemia with Gla300 was also significantly lower than that of Deg.
Conclusions
The present study showed the comparable efficacy of Gla300 and Deg on glycemic control; however, the risk of hypoglycemia was markedly lower for Gla300 than for Deg.
Keywords: Glargine 300, Hypoglycemia, Serum albumin
Introduction
In patients with type 2 diabetes, intensive glucose control initiated immediately after the onset of diabetes is well known to be effective in preventing diabetic complications1. However, intensive glucose control reportedly increases the risk of hypoglycemia2, and severe hypoglycemia is an important risk factor for adverse events, cardiovascular disease and mortality3. Furthermore, hypoglycemia and the fear of it, which are seriously concerning for patients, have been shown to inhibit aggressive treatment outcomes4 and reduce the quality of life5. Therefore, achieving favorable glycemic control and preventing hypoglycemia are regarded as the most important measures in the treatment of diabetes.
Basal insulin analogs have been developed to produce a more constant and prolonged pharmacokinetic and pharmacodynamic action profile, which allows patients to optimize glycemic control while minimizing hypoglycemia risk6, 7. While insulin glargine 100 U/mL (Gla100) is the most commonly used long‐acting basal insulin, insulin glargine 300 U/mL (Gla300) and insulin degludec (Deg) are recently approved ultralong‐acting, once‐daily basal insulins. Both insulins have reportedly been associated with a more constant glucose‐lowering effect throughout the day8, 9, reduced the risk of hypoglycemia at any time of day and reduced the risk of nocturnal hypoglycemia when compared with Gla1008, 10, 11, 12, which is presently the most widely used basal insulin. Notably, in patients with type 2 diabetes, Gla300 and Deg are individually safer than Gla100 in either basal insulin ± oral antidiabetic drugs (OADs) therapy or basal–bolus insulin therapy13, 14, 15, 16, 17. Thus, Gla100 is expected to be replaced by these two ultralong‐acting insulins in the future. However, which of these two insulins is more effective and safe remains to be determined.
In the present study, patients with type 2 diabetes who were admitted and controlled for dietary intake and physical activity received Gla300 and Deg, and their efficacy and safety on glycemic control were compared.
Methods
Study design and participants
The present single‐center, randomized, open‐label, parallel‐group, two‐period, cross‐over study of patients with type 2 diabetes was carried out from July to December 2016. This study was carried out in accordance with the Declaration of Helsinki (1975, as revised in 2013). The study protocol was approved by the ethics committee of Minami Osaka Hospital (no. 2016‐6), and registered with the University Hospital Medical Information Network Clinical Trial Registry (UMIN000031044) after the study was completed. All participants provided written informed consent before the study.
We enrolled 30 patients with type 2 diabetes, including 18 men and 12 women, who were admitted to Minami Osaka Hospital, Osaka, Japan, for the purpose of glycemic control and education. Inclusion criteria comprised of age ≥20 years, diagnosed with type 2 diabetes based on the American Diabetes Association Criteria18 for at least 1 year before screening, having OADs and/or any insulin therapy for at least 6 months before screening. Patients with a glycated hemoglobin (HbA1c) level of <6.5% (48 mmol/mol) or >11.0% (97 mmol/mol) at screening, unstable retinopathy, diabetic kidney disease with severely decreased estimated glomerular filtration rate (<30 mL/min/1.73 m2) or overt proteinuria, pregnant women, history of gastrointestinal surgery, presence of cancer and clinically important cardiac, renal, hepatic or other systemic diseases were excluded from this study.
Figure 1 shows the study protocol. Participants enrolled in the study were randomized to Gla300‐Deg (Gla300/Deg) or Deg‐Gla300 (Deg/Gla300) sequence groups. All participants received once‐daily injections of either Gla300 (Sanofi, Paris, France) or Deg (Novo Nordisk, Bagsværd, Denmark), and each basal insulin was administered in accordance with the previous report9, with a small modification in the first treatment period (Figure 1; treatment period 1). In brief, participants previously treated with OADs continued their prestudy OAD treatment without any change in dose or regimen. The starting dose of Gla300 or Deg for basal insulin‐naïve participants was 4 U. Participants receiving basal insulin before the study were switched to Gla300 or Deg on a unit‐for‐unit dose basis without any change of bolus insulin. Participants receiving premixed insulin before the study were switched to basal–bolus insulin therapy with Gla300 or Deg, and the short‐acting insulin with the same dose of intermediate‐acting and short‐acting insulin included in the premixed insulin, respectively. Then, based on the self‐monitoring of blood glucose (SMBG), basal insulin doses were titrated to a target preprandial glucose concentration of 100–130 mg/dL at breakfast. We have >10 days titration period after randomization to eliminate the effect of the release of glucose toxicity. The basal insulin dose was titrated no more often than every 3–4 days. Furthermore, bolus insulin doses were titrated to the target preprandial and before bed glucose concentrations of 100–130 mg/dL. After setting the insulin doses, we confirmed that fluctuations in glucose levels before breakfast, lunch, supper and bedtime were individually stabilized within 10% for ≥3 days, and hypoglycemia was not documented by SMBG. After that, we evaluated their glycemic control in a blinded fashion using iPro™2 Professional continuous glucose monitoring (CGM, Medtronic, Inc.; Northridge, California, USA) for five consecutive days. Subsequently, their basal insulin was switched from Gla300 to Deg and vice versa in the second treatment period (Figure 1). After washing out the former basal insulin for more than 3–4 days, confirmed by SMBG profile, we again evaluated their glycemic control using CGM for five consecutive days. Dosage of OADs, bolus insulin and basal insulin was not changed in the second treatment period. CGM recorded glucose values for the last 5 days in each treatment period, and we used 3 days in the middle to complete the 24‐h recording sets.
Figure 1.
The study protocol. CGM, continuous glucose monitoring; Deg, insulin degludec; Gla300, insulin glargine 300 U/mL.
Each participant was given the following hospital diet with the same calorie and carbohydrate amount: 25–30 kcal/ideal bodyweight/day with a certain component ratio of calories (carbohydrate 60%, proteins 17% and lipids 23%; breakfast 30%, lunch 35% and supper 35%). To match the physical activity during the study period, patients were prohibited from carrying out excessive exercise, except moderate aerobic exercise for 30 min per day.
Outcome measures
The primary end‐points of the present study included the efficacy and safety outcomes based on the CGM parameters. The efficacy outcome was the mean percentage of time within the predefined CGM glucose range of 70–180 mg/dL, expressed as target range, for three consecutive days of each treatment period. The safety outcome was the mean percentage of time with glucose levels of <70 mg/dL, expressed as hypoglycemic range19, 20. Secondary end‐points based on CGM included the 24‐h mean glucose level, nocturnal (00.00–06.00 hours), morning (08.00–12.00 hours) and afternoon (12.00–24.00 hours) mean glucose levels; 24‐h standard deviation (SD) of the glucose levels; 24‐h coefficients of variation (CV) of the glucose levels21; 24‐h M‐value (target glucose level 100 mg/dL)22; and mean percentage of time with severe hypoglycemia (<54 mg/dL)23, with nocturnal (00.00–06.00 hours) hypoglycemia (<70 mg/dL) and with hyperglycemia (≥180 mg/dL) for three consecutive days. The mean amplitude of glycemic excursion22, 24 was calculated from the CGM data considering the glycemic peaks and nadirs recorded over a 24‐h period for three consecutive days. The mean of daily difference (MODD) for a 24‐h period was used as an index of day‐to‐day glucose variability22, 24.
Statistical analysis
Data are expressed as the mean ± SD, unless otherwise indicated. Findings were compared between two treatments using the Student's t‐test25. The number of hypoglycemic events on each clock time was compared using the McNemar's test. The carry over and period effects in the cross‐over study were verified using the repeated measured analysis of variance (anova) according to the Grieve method26. A P‐value of <0.05 was considered significant for all other analyses. Statistical analyses were carried it using JMP 10 software (SAS Institute Inc., Cary, North Carolina, USA).
Results
Participant characteristics
A total of 30 participants with type 2 diabetes enrolled in the study were randomized for Gla300/Deg (n = 15) or Deg/Gla300 (n = 15) and were included in the intention‐to‐treat population. All participants completed the study (Figure S1). Initially, the breakdown of treatment was insulin naïve and OADs (n = 13), basal–bolus insulin therapy (n = 5), basal insulin ± OADs therapy (n = 4) and premixed insulin therapy (n = 8). Gla100 had been used as a basal insulin by all patients. Baseline characteristics were similar in all treatment groups (Table 1). After the entry, patients received either basal–bolus insulin therapy (n = 13) or basal insulin ± OADs therapy (n = 17). The basal insulin doses titrated during treatment period 1 (Figure 1) were insignificantly different between the Gla300/Deg and Deg/Gla300 groups (0.17 ± 0.10 and 0.22 ± 0.15 U/kg/day, respectively).
Table 1.
Baseline characteristics of randomized participants
Overall (n = 30) | Gla300/Deg (n = 15) | Deg/Gla300 (n = 15) | P‐value* | |
---|---|---|---|---|
Age (years) | 69.5 ± 11.3 | 71.1 ± 9.2 | 67.9 ± 13.2 | 0.449 |
Duration of diabetes (years) | 18.3 ± 11.3 | 18.5 ± 10.4 | 18.1 ± 12.5 | 0.937 |
Male, n (%) | 18 (60.0) | 8 (53.3) | 10 (66.7) | 0.151 |
BMI (kg/m2) | 24.6 ± 4.8 | 25.3 ± 4.8 | 24.0 ± 5.0 | 0.468 |
HbA1c (%) | 8.2 ± 1.9 | 8.5 ± 2.2 | 8.0 ± 1.5 | 0.469 |
S‐CPR (ng/mL) | 1.8 ± 1.7 | 1.9 ± 1.8 | 1.8 ± 1.6 | 0.883 |
eGFR (mL/min/1.73 m2) | 67.9 ± 22.7 | 66.6 ± 25.0 | 69.1 ± 20.8 | 0.763 |
S‐albumin (g/dL) | 3.7 ± 0.5 | 3.8 ± 0.5 | 3.7 ± 0.5 | 0.589 |
Prestudy treatment | ||||
OADs only (n) | 13 | 6 | 7 | 0.337 |
Basal/bolus insulin (n) | 5 | 3 | 2 | 0.374 |
Basal insulin dosage (U/day) | 13.6 ± 15.1 | 6.0 ± 3.5 | 25.0 ± 21.2 | 0.196 |
Bolus insulin dosage (U/day) | 16.8 ± 9.1 | 12.0 ± 4.0 | 24.0 ± 11.3 | 0.170 |
Basal insulin ± OADs (n) | 4 | 2 | 2 | 1.000 |
Basal insulin dosage (U/day) | 15.5 ± 10.0 | 22.0 ± 11.3 | 9.0 ± 1.4 | 0.248 |
Premixed insulin (n) | 8 | 4 | 4 | 1.000 |
Dosage (U/day) | 21.3 ± 9.2 | 21.0 ± 9.6 | 21.5 ± 10.2 | 0.946 |
Antidiabetic agents other than insulin | ||||
DPP4 inhibitor (n) | 14 | 7 | 7 | 1.000 |
Metformin (n) | 10 | 3 | 7 | 0.123 |
SGLT2 inhibitor (n) | 2 | 2 | 0 | 0.153 |
Sulfonylurea (n) | 3 | 2 | 1 | 0.559 |
Glinide (n) | 1 | 1 | 0 | 0.326 |
α‐GI (n) | 3 | 1 | 2 | 0.559 |
GLP‐1RA (n) | 1 | 1 | 0 | 0.326 |
Values are expressed as mean ± standard deviation. *Data were compared between two sequence groups using the Student's t‐test or χ2‐test. Antidiabetic drugs other than insulin were not changed throughout the study period. α‐GI, alpha‐glucosidase inhibitor; BMI, body mass index; DPP4, dipeptidyl peptidase‐4; eGFR, estimated glomerular filtration rate; GLP‐1RA, glucagon‐like peptide‐1 receptor agonists; HbA1c, glycated hemoglobin; OADs, oral antidiabetic drugs; S‐CPR, serum C‐peptide immunoreactivity; s‐albumin, serum albumin; SGLT2, sodium–glucose cotransporter 2.
Comparison of efficacy and safety between Gla300 and Deg
The primary end‐points of the present study were the mean percentage of time within the target glucose range of 70–180 mg/dL as efficacy and with hypoglycemia (<70 mg/dL) as safety. The mean percentage of time within the target glucose range was not different between Gla300 and Deg. However, the mean percentage of time with hypoglycemia with Deg was much higher than that of Gla300 (Table 2). Regarding the mean percentage of time within the target glucose range and time with hypoglycemia, neither the carry over (P = 0.0636 and 0.4141, respectively) nor the period effect (P = 0.2712 and 0.1257, respectively) was observed in the present cross‐over study.
Table 2.
Continuous glucose monitoring parameters of glucose variability in patients with insulin glargine 300 U/mL or degludec
Gla300 | Deg | P‐value | |
---|---|---|---|
Mean percentage of time with target glucose range 70–180 mg/dL (%) | 77.8 ± 19.2 | 76.9 ± 18.3 | 0.848 |
Mean percentage of time with hyperglycemia ≥180 mg/dL (%) | 20.9 ± 19.0 | 17.7 ± 18.3 | 0.505 |
24‐h SD (mg/dL) | 36.3 ± 11.7 | 38.9 ± 11.7 | 0.094 |
24‐h M‐value (target glucose level 100 mg/dL) | 10.1 ± 9.0 | 10.0 ± 9.1 | 0.938 |
24 h CV (%) | 25.0 ± 6.3 | 28.9 ± 7.1 | 0.028* |
00.00–06.00 hours CV (%) | 13.9 ± 6.5 | 18.5 ± 9.5 | 0.031* |
MAGE (mg/dL) | 91.5 ± 27.2 | 92.4 ± 24.6 | 0.885 |
MODD (mg/dL) | 22.5 ± 8.7 | 27.6 ± 9.8 | 0.035* |
24‐h mean glucose level (mg/dL) | 144.4 ± 36.3 | 134.3 ± 26.5 | 0.141 |
00.00–06.00 hours mean glucose level (mg/dL) | 113.9 ± 28.3 | 101.8 ± 34.4 | 0.107 |
08.00–12.00 hours mean glucose level (mg/dL) | 166.8 ± 38.7 | 154.7 ± 41.1 | 0.199 |
12.00–24.00 hours mean glucose level (mg/dL) | 156.2 ± 33.3 | 148.1 ± 32.9 | 0.317 |
Preprandial glucose level at breakfast (mg/dL) | 122.2 ± 22.2 | 111.1 ± 30.5 | 0.100 |
Preprandial glucose level at lunch (mg/dL) | 141.3 ± 28.1 | 129.5 ± 25.5 | 0.094 |
Preprandial glucose level at supper (mg/dL) | 136.7 ± 28.3 | 126.1 ± 34.1 | 0.193 |
Mean percentage of time with hypoglycemia <70 mg/dL (%) | 1.3 ± 2.7 | 5.5 ± 6.4 | 0.002* |
Mean percentage of time with severe hypoglycemia <54 mg/dL (%) | 0.04 ± 0.18 | 1.8 ± 3.0 | 0.003* |
Mean percentage of time with nocturnal hypoglycemia <70 mg/dL (%) | 1.1 ± 2.4 | 4.2 ± 5.8 | 0.009* |
Values are expressed as mean ± standard deviation. *Data were compared using Student's t‐test. A P‐value of <0.05 was considered significant. CV, coefficient of variation; MAGE, the mean amplitude of glycemic excursion; MODD, mean of daily difference; SD, standard deviation of the glucose levels.
For the secondary efficacy end‐points, the 24‐h mean glucose level; the nocturnal (00.00–06.00 hours), morning (08.00–12.00 hours) and afternoon (12.00–24.00 hours) mean glucose levels or the mean percentage of time with hyperglycemia (≥180 mg/dL) were insignificantly different between the two insulins. No significant differences were observed between the two insulins in any of the indices of diurnal variation in glucose levels; that is, the 24‐h SD of the glucose levels, the 24‐h M‐value and mean amplitude of glycemic excursion. However, CV, an index of a more sensitive index of diurnal variation in glucose level and MODD, and an index of day‐to‐day variation, were significantly higher for Deg than for Gla300 (Table 2). Regarding the secondary safety end‐points, the mean percentage of time with severe hypoglycemia (<54 mg/dL) and nocturnal hypoglycemia were also evaluated. Both values were markedly higher for patients treated with Deg than those treated with Gla300 (Table 2). Figure 2 shows the average daily glucose profiles for three consecutive days measured using CGM. The glucose variations were similar between all participants (Figure 2a) and those treated with basal insulin ± OADs therapy (Figure 2b). Although the nocturnal (00.00–06.00 hours) mean glucose levels were insignificantly different between Gla300 and Deg (Table 2), those for Deg tended to be lower than those for Gla300 (Figure 2). Therefore, more patients were developing substantial hypoglycemia at night during Deg treatment than during Gla300 treatment (Figure S2). This trend was equally observed in both, all patients and those only receiving basal insulin ± OADs therapy. Although no significant difference between Gla300 and Deg was observed in preprandial glucose levels either (Table 2), they tended to be lower for Deg than for Gla300 (Figure 2).
Figure 2.
The 24‐h glucose variations based on continuous glucose monitoring. The mean glucose variations for 3 days of (a) the total patients (n = 30) and (b) patients treated with basal insulin ± oral antidiabetic drugs (OADs) therapy (n = 17). Solid and dotted lines show the glucose variations in patients receiving insulin glargine 300 U/mL (Gla300) and degludec (Deg), respectively.
Correlation between hypoglycemia and serum albumin concentration in patients treated with Deg
In the present study, factors associated with hypoglycemia were also investigated. Although no association between hypoglycemia and serum albumin concentrations was observed during Gla300 treatment (Figure 3a,c), serum albumin concentrations were strongly, negatively correlated with both the mean percentage of time with daily hypoglycemia and with nocturnal hypoglycemia (Figure 3b,d). Furthermore, because the correlations with daily and nocturnal hypoglycemia were almost comparable (Figure 3b,d), the association between hypoalbuminemia and hypoglycemia appeared to mainly reflect the association with nocturnal hypoglycemia. Age, sex, duration of diabetes, bodyweight, body mass index, C‐peptide reactivity, estimated glomerular filtration rate, HbA1c, low‐density lipoprotein, high‐density lipoprotein or triglyceride were not associated with hypoglycemia (data not shown).
Figure 3.
The relationship between hypoglycemia and serum albumin (s‐alb) concentration. The association between the mean percentage of time and (a, b) daily hypoglycemia (<70 mg/dL) or (c, d) nocturnal (00.00–06.00 hours) hypoglycemia for three consecutive days based on continuous glucose monitoring and serum albumin concentrations are shown. Daily or nocturnal hypoglycemia time was strongly correlated with serum albumin concentrations in (b, d) patients treated with insulin degludec (Deg), unlike (a, c) with insulin glargine 300 U/mL (Gla300) treatment. The Pearson product‐moment correlation coefficient (r) was used to study the relationship. A P‐value of <0.05 was considered significant.
Discussion
In the present study using CGM, the efficacy and safety were compared between Gla300 and Deg on glycemic control in patients with type 2 diabetes. When Gla300 and Deg were compared at the same units, they achieved comparable glycemic control and efficacy. However, regarding the safety, the risk of hypoglycemia was markedly lower for Gla300 than for Deg.
Because severe hypoglycemia and nocturnal hypoglycemia have been recognized as major limiting factors for intensive glycemic control27, and risk factors for adverse events, cardiovascular disease and mortality3, 28, important measures for the treatment of diabetes have been developed mainly to prevent hypoglycemia and to simultaneously achieve favorable glycemic control. The present study showed that the frequency of hypoglycemia (particularly nocturnal hypoglycemia) recorded by CGM was significantly lower during Gla300 treatment than during Deg treatment. Furthermore, in the present study, although no significant differences in the indices of diurnal variation (the 24‐h SD of the glucose levels, the 24‐h M‐value and mean amplitude of glycemic excursion) were observed between Deg and Gla300 treatments, CV, an index of a more sensitive index of diurnal variation in glucose level and MODD, and an index of day‐to‐day variation were significantly higher during Deg treatment than during Gla300 treatment. As a cause, there was a significant difference in the frequency of nocturnal hypoglycemia even though there was no difference in the mean glucose level, and it was considered that there was a significant difference in CV between the two groups. Because the fasting plasma glucose (FPG) levels in patients who developed nocturnal hypoglycemia were significantly higher in the morning after the event than on the previous day (data not shown), the significantly higher MODD during Deg treatment was assumed to have been attributable to the Somogyi effect induced by nocturnal hypoglycemia. Either finding indicates the superiority of Gla300 to Deg in safety. Comparing Gla300 and Deg 24‐h pharmacodynamics and pharmacokinetics, there are reports of Gla300 providing less fluctuating steady‐state pharmacodynamics profiles (i.e., lower within‐day variability) and more evenly distributed pharmacokinetic profiles, compared with Deg. It was thought that this action profile was linked to the results of the present study this time29.
In the present study, the basal insulin doses were titrated to the mild target FPG range of 100–130 mg/dL to prevent hypoglycemia, and the target was achieved (Table 2). It should be noted that even after adjusting the basal insulin doses to the target glucose levels, which seemed relatively safe, nocturnal hypoglycemia was caused by Deg in a very large number of patients (Figure 2S). Many studies showed that hypoglycemic events were markedly less frequently caused by Deg than by Gla10030, and the incidence of hypoglycemic events in patients receiving Deg in these studies was much lower than that in the present study14, 16, 17, 31. The discrepancy in the incidence of hypoglycemia between the previous and present studies might be attributable to different methods in monitoring glucose levels and definitions of hypoglycemia. In the SWITCH 1 and 2 trials16, 31 and the BEGIN study14, 17, the basal insulin doses were adjusted to a target FPG range of 70–90 mg/dL, and achieved FPG levels that were consistent with the levels obtained in the present study (100–130 mg/dL). However, because glucose levels were monitored with SMBG instead of CGM, all asymptomatic nocturnal hypoglycemic events were not always detected32. Furthermore, because hypoglycemia was defined as a plasma glucose level of <56 mg/dL in these studies, some hypoglycemic events (plasma glucose of 56–70 mg/dL) were not counted. Thus, many hypoglycemic events, particularly nocturnal hypoglycemia, should be considered in these studies. In fact, another study in which FPG levels were controlled at levels comparable with those observed in the present study reported that hypoglycemia (plasma glucose of <70 mg/dL) and nocturnal hypoglycemia monitored with CGM were frequently observed in patients receiving Deg20, which is consistent with the present study. Thus, when Deg is used, nocturnal hypoglycemia should be carefully considered. In addition, because the insulin requirement is reported to be lower for Deg than for Gla100 to achieve comparable glycemic control30, insulin doses can be reduced at the time of switching from Gla300 to Deg.
More interestingly, the present study showed that the mean percentage of time with hypoglycemia, particularly with nocturnal hypoglycemia, during Deg treatment significantly, negatively correlated with albumin levels (Figure 3). Although the reasons for the association between decreased albumin levels and hypoglycemia caused by Deg are unknown, a possible reason was identified. It is the reversible binding of Deg to albumin. Deg forms a depot of soluble multihexamers after injection into the subcutaneous tissue, with subsequent stable and slow release of monomers into the circulation33. Although this is the major mechanism underlying the prolonged and stable effect of Deg, the binding of Deg to albumin is also one of the factors explaining the stability and prolonged duration of Deg effects33. Gla300 does not bind to albumin34, 35. In contrast, ≥99% of Deg reversibly binds to albumin and is released from albumin in the target tissue to exert the glucose‐lowering effects36, 37. As the serum albumin levels are much higher than Deg concentrations at therapeutic doses (>10,000‐fold), the pharmacokinetic properties of Deg are not considered to be affected by even large changes in albumin concentrations36. Deg has determined the association constant (Ka = B/[F × HSAimm]), B/F is the ratio between bound and free insulin, and HSAimm is the total concentration of immobilized albumin33. Furthermore, serum albumin levels become high values in the daytime, and the lowest values at night38. It means when serum albumin levels decrease at night, bound insulin decreases; in contrast, free insulin increases to maintain a constant Ka. As free insulin exerts the effect attached to the insulin receptor, Deg might exert a strong effect at night and cause nocturnal hypoglycemia. However, a study that actually examines the association between the efficacy or safety of Deg and albumin concentrations has not been published yet. Furthermore, competitive substances, such as bilirubin and free fatty acids (FFA), are known to actually affect the affinity between drugs and albumin39. Increased FFA levels at night were associated with increased growth hormone levels40. Notably, in patients with diabetes, the inhibitory effect of insulin on FFA is reduced41, and FFA levels markedly increase at night42. Because insulin detemir, known to bind to albumin as with Deg, has been shown to be released from albumin in association with an increased ratio of FFA to albumin levels43, the reported FFA concentrations at night in patients with diabetes42 can theoretically induce insulin release at low albumin concentrations43. Thus, the combination of hypoalbuminemia and increased FFA levels at night might lead to nocturnal hypoglycemia during Deg treatment.
The present study had several limitations. The first limitation was that we did not assess the possibility that the doses required to yield the same effect might differ between Gla300 and Deg. In the present short‐term study, insulin doses titrated during the first treatment period were not changed during the study period, and Gla300 and Deg were also administered at the same units after switching. This study revealed the differences between Gla300 and Deg effects with the same units on glycemic variability. However, according to studies comparing Deg and Gla100 for the efficacy and safety on long‐term glycemic control, the insulin requirement to achieve the same level of glycemic control with Deg is lower than that with Gla100, and these studies showed that the incidence of hypoglycemia caused by Deg is markedly lower with reduced insulin doses16, 30, 31. If the basal insulin doses had been titrated based on the incidence of hypoglycemia and FPG levels after switching between Gla300 and Deg, the administered amount of insulin would have been smaller during Deg treatment than during Gla300 treatment; consequently, the incidence of hypoglycemia might have been reduced. To compare the efficacy and safety in actual treatment, long‐term glycemic control, incidence of hypoglycemia, and risks of cardiovascular events and death should be investigated in a multicenter, randomized, double‐blinded, parallel‐group study with a protocol requiring adjustment of insulin doses based on the glycemic status of daily life.
The second limitation was that although Deg more likely causes nocturnal hypoglycemia in patients with hypoalbuminemia (Figure 3), the correlation between nocturnal hypoglycemia and diurnal variation of serum albumin was not investigated in the present study. To ensure the efficacy and safety of Deg, further studies should be carried out on whether or how hypoalbuminemia affects glycemic control with Deg. If hypoalbuminemia is a predictor of nocturnal hypoglycemia caused by Deg, it might be one of the indicators in selecting appropriate treatment.
The efficacy and safety of Gla300 and Deg in patients with type 2 diabetes were compared and analyzed in a randomized cross‐over study using CGM. When comparing these two insulins with the same units, their effects were similar in achieving the target glycemic control; however, Gla300 was safer than Deg with regard to hypoglycemia, particularly nocturnal hypoglycemia. Furthermore, the present study suggested that hypoalbuminemia might be a predictor of nocturnal hypoglycemia caused by Deg.
The third limitation was FFA and Deg unbound albumin were not measured in the present study, so the involvement of FFA and Deg unbound albumin remains unknown. Therefore, it needs to be investigated in future studies.
Disclosure
YK has received honoraria for lectures or speaker's fee from Sanofi K.K., Novo Nordisk Pharma, MSD, Takeda Pharmaceutical Co., Sanofi‐Aventis, Ono Pharmaceutical Co., Boehringer Ingelheim, Taisho Toyama Pharmaceutical Co. and Novartis Pharma K.K. The other authors declare no conflict of interest.
Supporting information
Figure S1| Enrollment of participants in the study.
Figure S2| Participants with documented hypoglycemic events.
Acknowledgments
The authors were fully responsible for all content and editorial decisions, were involved in all stages of manuscript development, and have approved the final version. The authors thank the staff of Minami Osaka Hospital for their great help.
J Diabetes Investig 2019; 10: 343–351
Clinical Trial Registry
University Hospital Medical Information Network Clinical Trial Registry
UMIN000031044
References
- 1. Stratton IM, Adler AI, Neil HAW, et al Association of glycaemia with macrovascular and microvascular complications of type 2 diabetes (UKPDS 35): prospective observational study. BMJ 2000; 321: 405–412. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2. Ray KK, Seshasai SR, Wijesuriya S, et al Effect of intensive control of glucose on cardiovascular outcomes and death in patients with diabetes mellitus: a meta‐analysis of randomised controlled trials. Lancet 2009; 373: 1765–1772. [DOI] [PubMed] [Google Scholar]
- 3. Miller ME, Williamson JD, Gerstein HC, et al Effects of randomization to intensive glucose control on adverse events, cardiovascular disease, and mortality in older versus younger adults in the ACCORD Trial. Diabetes Care 2014; 37: 634–643. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4. Peyrot M, Barnett AH, Meneghini LF, et al Insulin adherence behaviours and barriers in the multinational Global Attitudes of Patients and Physicians in Insulin Therapy study. Diabet Med 2012; 29: 682–689. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5. Cooke D, O'Hara MC, Beinart N, et al Linguistic and psychometric validation of the Diabetes‐Specific Quality‐of‐Life Scale in U.K. English for adults with type 1 diabetes. Diabetes Care 2013; 36: 1117–1125. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6. Heise T, Nosek L, Ronn BB, et al Lower within‐subject variability of insulin detemir in comparison to NPH insulin and insulin glargine in people with type 1 diabetes. Diabetes 2004; 53: 1614–1620. [DOI] [PubMed] [Google Scholar]
- 7. Porcellati F, Rossetti P, Busciantella NR, et al Comparison of pharmacokinetics and dynamics of the long‐acting insulin analogs glargine and detemir at steady state in type 1 diabetes: a double‐blind, randomized, crossover study. Diabetes Care 2007; 30: 2447–2452. [DOI] [PubMed] [Google Scholar]
- 8. Strong J, Kruger D, Novak L. Insulin glargine 300 units/mL: a guide for healthcare professionals involved in the management of diabetes. Curr Med Res Opin 2017; 33: 785–793. [DOI] [PubMed] [Google Scholar]
- 9. Meneghini L, Atkin SL, Gough SC, et al The efficacy and safety of insulin degludec given in variable once‐daily dosing intervals compared with insulin glargine and insulin degludec dosed at the same time daily: a 26‐week, randomized, open‐label, parallel‐group, treat‐to‐target trial in individuals with type 2 diabetes. Diabetes Care 2013; 36: 858–864. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10. Ritzel R, Roussel R, Bolli GB, et al Patient‐level meta‐analysis of the EDITION 1, 2 and 3 studies: glycaemic control and hypoglycaemia with new insulin glargine 300 U/ml versus glargine 100 U/ml in people with type 2 diabetes. Diabetes Obes Metab 2015;17:859–867. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11. Ratner RE, Gough SC, Mathieu C, et al Hypoglycaemia risk with insulin degludec compared with insulin glargine in type 2 and type 1 diabetes: a pre‐planned meta‐analysis of phase 3 trials. Diabetes Obes Metab 2013; 15: 175–184. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12. Marso SP, McGuire DK, Zinman B, et al Efficacy and safety of Degludec versus Glargine in type 2 diabetes. N Engl J Med 2017; 377: 723–732. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13. Yki‐Jarvinen H, Bergenstal R, Ziemen M, et al New insulin glargine 300 units/mL versus glargine 100 units/mL in people with type 2 diabetes using oral agents and basal insulin: glucose control and hypoglycemia in a 6‐month randomized controlled trial (EDITION 2). Diabetes Care 2014; 37: 3235–3243. [DOI] [PubMed] [Google Scholar]
- 14. Zinman B, Philis‐Tsimikas A, Cariou B, et al Insulin degludec versus insulin glargine in insulin‐naive patients with type 2 diabetes: a 1‐year, randomized, treat‐to‐target trial (BEGIN Once Long). Diabetes Care 2012; 35: 2464–2471. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15. Riddle MC, Bolli GB, Ziemen M, et al New insulin glargine 300 units/mL versus glargine 100 units/mL in people with type 2 diabetes using basal and mealtime insulin: glucose control and hypoglycemia in a 6‐month randomized controlled trial (EDITION 1). Diabetes Care 2014; 37: 2755–2762. [DOI] [PubMed] [Google Scholar]
- 16. Wysham C, Bhargava A, Chaykin L, et al Effect of insulin degludec vs insulin glargine U100 on hypoglycemia in patients with type 2 diabetes: the SWITCH 2 randomized clinical trial. JAMA 2017; 318: 45–56. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17. Garber AJ, King AB, Del Prato S, et al Insulin degludec, an ultra‐longacting basal insulin, versus insulin glargine in basal‐bolus treatment with mealtime insulin aspart in type 2 diabetes (BEGIN Basal‐Bolus Type 2): a phase 3, randomised, open‐label, treat‐to‐target non‐inferiority trial. Lancet 2012; 379: 1498–1507. [DOI] [PubMed] [Google Scholar]
- 18. American Diabetes Association 2. Classification and diagnosis of diabetes. Diabetes Care 2017; 40: S11–S24. [DOI] [PubMed] [Google Scholar]
- 19. Bergenstal RM, Bailey TS, Rodbard D, et al Comparison of insulin glargine 300 Units/mL and 100 Units/mL in adults with type 1 diabetes: continuous glucose monitoring profiles and variability using morning or evening injections. Diabetes Care 2017; 40: 554–560. [DOI] [PubMed] [Google Scholar]
- 20. Iga R, Uchino H, Kanazawa K, et al Glycemic variability in type 1 diabetes compared with degludec and glargine on the morning injection: an open‐label randomized controlled trial. Diabetes Ther 2017; 8: 783–792. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21. Investigators F‐ST . Glucose variability in a 26‐week randomized comparison of mealtime treatment with rapid‐acting insulin versus GLP‐1 agonist in participants with type 2 diabetes at high cardiovascular risk. Diabetes Care. 2016;39:973–981. [DOI] [PubMed] [Google Scholar]
- 22. Siegelaar SE, Holleman F, Hoekstra JB, et al Glucose variability; does it matter? Endocr Rev 2010; 31: 171–182. [DOI] [PubMed] [Google Scholar]
- 23. International Hypoglycaemia Study Group . Glucose concentrations of less than 3.0 mmol/L (54 mg/dL) should be reported in clinical trials: a Joint Position Statement of the American Diabetes Association and the European Association for the Study of Diabetes. Diabetes Care 2017; 40: 155–157. [DOI] [PubMed] [Google Scholar]
- 24. Service FJ, Nelson RL. Characteristics of glycemic stability. Diabetes Care. 1980;3:58–62. [DOI] [PubMed] [Google Scholar]
- 25. Jones B, Kenward MG. Design and Analysis of Cross‐over Trials [still image]. Boca Raton, FL: Chapman & Hall/CRC, 2014:18–26. [Google Scholar]
- 26. Grieve AP. The two‐period changeover design in clinical trials. Biometrics 1982; 38: 517. [PubMed] [Google Scholar]
- 27. Cryer PE. Hypoglycaemia: the limiting factor in the glycaemic management of type I and type II diabetes. Diabetologia 2002; 45: 937–948. [DOI] [PubMed] [Google Scholar]
- 28. Goto A, Arah OA, Goto M, et al Severe hypoglycaemia and cardiovascular disease: systematic review and meta‐analysis with bias analysis. BMJ 2013; 347: f4533. [DOI] [PubMed] [Google Scholar]
- 29. Bailey TS, Pettus J, Roussel R, et al Morning administration of 0.4U/kg/day insulin glargine 300U/mL provides less fluctuating 24‐hour pharmacodynamics and more even pharmacokinetic profiles compared with insulin degludec 100U/mL in type 1 diabetes. Diabetes Metab 2018; 44: 15–21. [DOI] [PubMed] [Google Scholar]
- 30. Vora J, Christensen T, Rana A, et al Insulin degludec versus insulin glargine in type 1 and type 2 diabetes mellitus: a meta‐analysis of endpoints in phase 3a trials. Diabetes Ther 2014; 5: 435–446. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31. Lane W, Bailey TS, Gerety G, et al Effect of insulin degludec vs insulin glargine U100 on hypoglycemia in patients with type 1 diabetes: the SWITCH 1 randomized clinical trial. JAMA 2017; 318: 33–44. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32. Gehlaut RR, Dogbey GY, Schwartz FL, et al Hypoglycemia in type 2 diabetes‐more common than you think: a continuous glucose monitoring study. J Diabetes Sci Technol 2015; 9: 999–1005. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33. Jonassen I, Havelund S, Hoeg‐Jensen T, et al Design of the novel protraction mechanism of insulin degludec, an ultra‐long‐acting basal insulin. Pharm Res 2012; 29: 2104–2114. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34. Heise T, Mathieu C. Impact of the mode of protraction of basal insulin therapies on their pharmacokinetic and pharmacodynamic properties and resulting clinical outcomes. Diabetes Obes Metab 2017; 19: 3–12. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35. Mathieu C, Gillard P, Benhalima K. Insulin analogues in type 1 diabetes mellitus: getting better all the time. Nat Rev Endocrinol 2017; 13: 385–399. [DOI] [PubMed] [Google Scholar]
- 36. Vora J, Cariou B, Evans M, et al Clinical use of insulin degludec. Diabetes Res Clin Pract 2015; 109: 19–31. [DOI] [PubMed] [Google Scholar]
- 37. Kalra S, Unnikrishnan AG, Baruah M, et al Degludec insulin: a novel basal insulin. Indian J Endocrinol Metab 2011; 15: S12–S16. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38. Jubiz W, Canterbury JM, Reiss E, et al Circadian rhythm in serum parathyroid hormone concentration in human subjects: correlation with serum calcium, phosphate, albumin, and growth hormone levels. J Clin Investig 1972; 51: 2040–2046. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39. Langmuir I. The adsorption of gases on plane surfaces of glass, mica and platinum. J Am Chem Soc 1918; 40: 1361–1403. [Google Scholar]
- 40. Broussard JL, Chapotot F, Abraham V, et al Sleep restriction increases free fatty acids in healthy men. Diabetologia 2015; 58: 791–798. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41. Caprio S, Amiel S, Tamborlane WV, et al Defective free‐fatty acid and oxidative glucose metabolism in IDDM during hypoglycemia. Influence of glycemic control. Diabetes 1990; 39: 134–141. [DOI] [PubMed] [Google Scholar]
- 42. Reaven GM, Hollenbeck C, Jeng CY, et al Measurement of plasma glucose, free fatty acid, lactate, and insulin for 24 h in patients with NIDDM. Diabetes 1988; 37: 1020–1024. [DOI] [PubMed] [Google Scholar]
- 43. Kurtzhals P, Havelund S, Jonassen I, et al Albumin binding of insulins acylated with fatty acids: characterization of the ligand‐protein interaction and correlation between binding affinity and timing of the insulin effect in vivo . Biochem J 1995; 312: 725–731. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Figure S1| Enrollment of participants in the study.
Figure S2| Participants with documented hypoglycemic events.