Abstract
Noninvasive light focusing and imaging through a scattering medium can be achieved by wavefront shaping using the photoacoustic signal as feedback. Unfortunately, the signal to noise ratio (SNR) of the traditional photoacoustic method is very low, which limits the wavefront shaping focusing speed and intensity. In this paper, we propose a completely new photoacoustic-signal-extraction method which combines wavelet denoising and correlation detection. With this method, the SNR of the photoacoustic signal reaches 25.2, 6.5 times higher than that of the unprocessed photoacoustic signal. Moreover, we achieve the simultaneous multipoint focusing, which is crucial for improving the speed of scanning imaging. The superior performance of the proposed method was experimentally demonstrated in extracting and denoising the photoacoustic signals deeply buried in noise, one critical step in in vivo photoacoustic imaging.
Introduction
Light focusing and imaging through highly scattering biological tissues is of great interest for biomedical applications. Traditional focusing and imaging techniques, such as optical coherence tomography (OCT) and confocal laser scanning microscope, utilize ballistic light. Since the ballistic light decreases exponentially with the penetration depth, these techniques can only be applied to superficial biological tissues1–3.
The emergence of wavefront shaping technology makes it possible to utilize diffuse light to focus and image, which effectively improves the depth of light focusing and imaging4. By compensating for the wavefront of the light before it arrives at scattering media, the light passing through scattering media can be controlled. Optical wavefront shaping technology has made great progress. It can now achieve ~μs level focusing speed and ~μm level resolution5,6. However, most of the researches so far have only focused light behind the scattering medium with pure optical wavefront shaping method. Because a feedback signal at the target point is needed during the wavefront shaping. Usually the light intensity at the target point acquired by the charge coupled device (CCD) camera is used as the feedback signal7,8. Since the CCD camera cannot be placed inside biological tissue without any damage, it is fatal for noninvasively wavefront shaping in living tissues. Some recent techniques have achieved noninvasive light focusing based on optical and acoustic interactions such as acousto-optic effect and photoacoustic effect9,10. The time-reversed ultrasonically encoded (TRUE) optical focusing technique utilizes the acousto-optic effect to generate an ultrasonic guide star, and the ultrasonically encoded light was used as the feedback signal. TRUE uses holography to time-reverse the ultrasonically encoded light and then forms a focal point within the scattering medium11. However, this method requires complex experimental optical setup and tedious experimental procedure. Besides, the ultrasound encoded light accounts for a fairly low proportion of the total scattered light which makes the signal detection more difficult12.
Photoacoustic wavefront shaping can overcome these shortcomings. Instead of optical signals, it uses acoustic signals generated based on photoacoustic effect as the feedback signals. The photoacoustic effect refers to the phenomenon that the absorber absorbs the energy of the laser pulse to generate thermal expansion and ultrasonic waves13. Comparing to the light, but the scattering of ultrasonic waves in biological tissues is much weaker. Photoacoustic wavefront shaping not only provides noninvasive feedback signals, but also improves the depth of light focusing and imaging. However, the application of photoacoustic signals to wavefront shaping is still relatively lacking. T. Chaigne et al. used the photoacoustic effect to measure the photoacoustic transmission matrix and realized photoacoustic wavefront shaping. Finally, they got an approximately 6 times enhancement of the photoacoustic signal14. Most researches of photoacoustic wavefront shaping use the phase-only spatial light modulator (SLM) to control the wavefront of incident light, but its application in living tissues with short decorrelation time is difficult considering the refresh rate of SLM (100 Hz)14–16. L. V. Wang et al. introduced a method that utilizes a digital micromirror device (DMD), which is capable of operating at 22 kHz,in the photoacoustic wavefront shaping system to increase the focusing speed17. However, these methods are limited by the problem that the SNR of the photoacoustic signal is poor. DMD surface can endure lower pulsed laser fluence (<200 μJ/cm2) than that of SLM (<40 mJ/cm2). Lower pulse laser fluence means weaker photoacoustic signal and lower SNR. The commom method to improve the SNR is to collect and average the photoacoustic signals for many times. This method can only slightly improve the SNR but takes much more time. L. V. Wang et al. averaged 64 acquisitions of photoacoustic signals, raising the SNR to 3.9. The optimization process still took about 2 hours with a high repetition rate pulse laser (1 kHz). In addition, O. Tzang et al. proposed a lock-in detection method and for photoacoustic signals and improved the SNR by an order of magnitude. However, their methods require complicated signal processing circuits and expensive light modulation devices such as acousto-optic modulator. Their experiments used a pulsed laser with a repetition rate of 20 kHz. It took 6 minutes to optimize the linear photoacoustic signals and nearly one hour for the nonlinear photoacoustic signals. The photoacoustic signals was enhanced 9 times and 16 times, respectively.
In this paper, we propose a method that combines wavelet denoising and correlation detection to improve the SNR of the photoacoustic signals. The acquired photoacoustic signals are digitallly processed and there is no need of any additional signal processing circuit. The SNR of the photoacoustic signal reaches 25.2, which is about 6.5 times higher than that of the photoacoustic signal before denoising. The proposed method significantly improves the focusing speed and intensity of the wavefront shaping technology using photoacoustic signals as feedback. With the improvement of SNR, we enhance the intensity of single point photoacoustic signal by 7.83 times using a binary amplitude modulation device DMD. Further, we achieve simultaneous multipoint focusing with a low frequency ultrasonic transducer. We can still obtain relatively high enhancements (3.7 and 2.4 times, respectively) when the two points average the energy of light. This is extremely advantageous for improving the speed of scanning imaging after focusing. Since a large number of repeated acquisitions of photoacoustic signals are not required, we achieve faster focusing speeds with lower pulse repetition rates (10 Hz).
Method
In this paper, we combine wavelet denoising and correlation detection to detect photoacoustic signals deeply buried in noise with improved SNR.
Wavelet denoising
Wavelet denoising has been widely used in signal and image processing technology for many years18–20. Different from simple frequency domain filtering, it filters out noise while preserving the details of the useful signal as much as possible. Wavelet denoising processes wavelet transform coefficients of signals and noiseis based on different representations of wavelet transforms at different scales of signal and noise21. The essence of denoising is to reduce or even eliminate the wavelet coefficients introduced by noise, while maximizing the wavelet coefficients of the signals. After wavelet transform, the wavelet coefficients of the signals have a strong correlation at each scale, while the wavelet coefficients corresponding to the noise have no such obvious correlation between these scales.
Ignoring the attenuation of sound waves, the basic model of noise-inducing photoacoustic signals can be written as follows22:
1 |
where ω is standard Gaussian white noise, which follows ω~N(0, 1) and σ is the noise level. h is the signal received by the oscilloscope. s(r) is the photoacoustic signal at r in the medium. The signal at position r can be written as follows13:
2 |
Γ is the Grüneisen parameter which is related to the properties of the medium, μa(r) is the absorption coefficient at r in the medium, φ(r) is the light fluence at position r. The detected photoacoustic signals are also related to the response of the detector. Since our experiment used the same ultrasonic transducer, this problem was not considered. The purpose of the wavelet denoising is to suppress the noise part σω of h and to recover s(r).
On the choice of the mother wavelet, one method is to select a wavelet similar to the waveform of the signal to be denoised as the denoising effect of the mother wavelet is better23. The waveform of the photoacoustic signal is related to the size of the absorber, the frequency of the ultrasonic transducer, and the relative position of the ultrasonic transducer and the absorber24. In this experiment, the daubechies wavelet, the symlet wavelet and the coiflet are tested. They are all similar to the waveform we have acquired and they are more commonly used in one-dimensional signal denoising. Since the smoothness of the signal affects the accuracy of the correlation detection method, we finally chose the fourth-order daubechies wavelet as the mother wavelet considering the smoothness and denoising. And the level of decomposition is eight. The threshold of wavelet denoising calculated using the common threshold proposed by Donoho and Johnstone for VisuShrink, which is where M is the signal length and σ is the estimated value of noisy variance. For one-dimensional signal the threshold results in an estimate asymptotically optimal in the minimax sense (minimizing the maximum error over all possible - sample signals)25.
Correlation detection
In addition to the photoacoustic signal and Gaussian white noise, the signal detected by the oscilloscope during the experiment was also mixed with clutters (Fig. 1) caused by device’s electrostatic and amplifier noise.
We performed a spectrum analysis of the signals and clutters before and after wavelet denoising (Fig. 2). From the spectrum analysis we can clearly see that these clutters usually contain the same frequency components as the photoacoustic signals (Fig. 2). This means band-pass filtering cannot eliminate these clutters which have a great influence on the extraction and optimization of the feedback signals.
In this paper, we propose a method that use the correlation coefficient to distinguish between photoacoustic signal and noise. The normalized correlation coefficient is calculated as equation26:
3 |
where γxy is a normalized correlation coefficient, N is the number of template points, x(n) are the template points, y(n) are the signal points under analysis, is the mean of the template points, is the mean of the signal points. The value of the normalized correlation coefficient is between −1 and 1, and 1 denotes the exact match between the signal under test and the template signal.
Although the speckle changes with the random-amplitude mask loaded on the DMD, the waveform of the photoacoustic signal changes very little since the same ultrasonic transducer is used. Thus, we could use the photoacoustic signals as templates to distinguish different waveforms of the photoacoustic signals and the noises. The selection of photoacoustic signal templates is described in detail in the later section of this paper.
In our experiments, different waveforms of the photoacoustic signals and the noises were collected, and their correlation coefficients were calculated. The correlation coefficients for the photoacoustic signals corresponding to different masks are above 0.8, and the correlation coefficients between photoacoustic signals and noises are below 0.4. Therefore, we set the correlation coefficient threshold to 0.7. After the correlation coefficient was calculated, the waveform with a correlation coefficient higher than 0.7 was selected as the photoacoustic signal, and the signal with the correlation coefficient lower than 0.7 was ignored. The photoacoustic signals corresponding to the same mask were collected five times for averaging.
During the experiment, we perform wavelet denoising on each acquired signal and use correlation detection to judge whether the collected signals are photoacoustic signals. The flow chart of the method is shown in Fig. 3.
The algorithm can be roughly divided into the following steps as shown in Fig. 3. (1) Once the program starts, the template S of the initial photoacoustic signal and the threshold T of the correlation detection algorithm are input. The template of the initial photoacoustic signal can be obtained through experimental measurement with the DMD pixel fully open. (2) The signal s(t) is acquired by the oscilloscope. (3) The acquired signal is denoised by wavelet and then the correlation coefficient C is calculated with the initial template. When the correlation coefficient C is lower than the set threshold T, it continues to return to step 2. (4) When the correlation coefficient C is higher than the set threshold T, the initial template S is replaced with the signal s(t) and save the peak-to-peak value p of s(t). Since the amplitude of the signal increases with the increase of generation during the optimization process, the replacement of the template further improves the accuracy of the relevant detection method. Each DMD mask collects five times signals, and then outputs the average peak-to-peak value P of the photoacoustic signals as the evaluation function of the genetic algorithm. Through the combination of the wavelet denoising and correlation detection, we can not only improve the SNR of photoacoustic signals, but also effectively filter out clutters. Even though the waveforms produced by different absorbers are different, we can focus multiple objects (such as blood vessels and muscles) by selecting multiple templates. Moreover, when there are different targets in the focusing range that can generate different photoacoustic signals, selecting an appropriate template can focus on different targets.
Experimental setup
The experimental setup is shown in Fig. 4. We used a 532 nm pulsed laser (SGR-10, LABest) with a repetition rate of 10 Hz and a pulse energy of ~800 μJ. The laser beam was expanded and collimated, then it was reflected by a mirror onto the DMD (DLP6500, Texas Instruments). The light reflected by the DMD was constricted and filtered by a 4f system and then focused by a 10× objective (NA = 0.25) onto a scattering diffuser (Diffuser 83419 Edmund Optics). A portion of the beam was split into the photodiode (S5971, Hamamatsu Photonics) to compensate for the energy fluctuations of the pulse laser. The photoacoustic signals were generated from an absorber embedded in an agarose gel. The absorber used in this paper is a 150 μm diameter black nylon thread, and the nylon thread was placed 3 cm behind the scattering sample to produce speckles approximate to the absorber. A 5 MHz ultrasonic transducer (5Z10SJ30DJ, SIUI) was used to collect the photoacoustic signals. The center frequencies of the photoacoustic signals generated by absorbers of different sizes are different. The center frequency is given by f ≈ 0.66cs/Da, Where cs is the speed of sound in water and Da is the diameter of the absorber24. The center frequency of the generated signals should be 6.6 MHz. Thus we use a 5 MHz ultrasonic transducer, whose bandwidth can cover the center frequency of the photoacoustic signals generated by our absorber. The photoacoustic signals were amplified by an amplifier (ZFL-500LN+, Mini-Circuits) and then acquired by an oscilloscope (WaveMaster 806Zi-A, LeCroy). The computer dealt with the data collected by the oscilloscope in real time and refreshed the mask loaded on the DMD according to the photoacoustic feedback signal. After the focusing experiment was complete, we replaced the absorber and the water tank with a CCD to obtain an image of the focus (MER-031-300GM, Daheng Imavision).
Results
In the experiment, we first implemented a wavefront shaping light focusing experimentin which the energy of incident light is relatively low and the corresponding photoacoustic signal used as the feedback has a low SNR. Then, we experimentally proved the effectiveness of wavelet denoising and correlation detection method by improving the optimization results. For the optimization,we implemented a geneti algorithm (GA) with stronger roubustness27.
In the optimization process, we divided the DMD into individual segments, each segment contains micromirrors. The larger the segment size, the larger the speckle after the laser passes through the scatterer, and the more it matches our larger absorption region, but larger segment size reduces the degrees of freedom we can control. Considering both aspects of speckle size and degrees of freedom, we finally chose the above segment size. Photoacoustic signals for different DMD masks were collected five times for averaging. The optimization process used a genetic algorithm which used photoacoustic signals as feedback. Random masks were generated as the initial populations, which were ranked in descending order by the fitness of the initial populations. In this experiment, the fitness value is the peak-to-peak value of the photoacoustic signal. Masks with high fitness values in each generation are easier to be selected to generate next generation by crossing and mutating. Through multiple iterations, an optimal mask, i.e. the mask with the largest peak-to-peak value of photoacoustic signal at the target point, was obtained28. In the experiment, we used 80 generations, and each generation contains 50 populations.
By calculating the ratio of the amplitude of the photoacoustic signal to the standard deviation of the noise without laser irradiation, we can measure the SNR17. The wavelet denoising can effectively improve the SNR of the photoacoustic feedback signal.
We calculated the SNR for 100 randomly acquired photoacoustic signals with different random masks loaded on the DMD. When the random mask was loaded, the average SNR of the photoacoustic signals without wavelet denoising is 3.86. The SNR of the photoacoustic signal reaches 25.2, which is about 6.5 times higher than that of the photoacoustic signal before denoising. The reason for the low initial SNR is that in addition to white noise, there is quantization noise introduced by oscilloscope in process of converting analog signals to digital signals. Figure 5 shows a representative result of increase of SNR of the photoacoustic signal processed by wavelet denoising. And the signals without clutters were selected by the correlation detection method.
In theory, the enhancement of the photoacoustic signal of optimal mask compared to the photoacoustic signal of random mask can be calculated by the following formula29:
4 |
where M is the number of independent optical modes contained within the absorbing area of the absorber inside the acoustic focal region, and N is the number of controllable modes on the DMD. Ultrasound transducer focus diameter , which is 880 μm in our experiment. cs is the speed of sound. F is the focal length of the ultrasonic transducer. f is the frequency of the ultrasonic transducer. D is the crystal diameter of the ultrasonic transducer. The absorber is a 150 μm diameter black nylon thread. Therefore, the size of the absorbing area inside the focal region of the transducer is 150 μm × 880 μm = 132000 μm2. According to the speckle diameter (150 μm) at the target position, we can calculate /. Therefore, the theoretical enhancement /.
The optimized result of the photoacoustic signal after optimization is shown in Fig. 6(a), The photoacoustic signal after optimization is approximately 7.83 times higher than the photoacoustic signal obtained with random mask loaded on the DMD, and 2.71 times higher than the photoacoustic signal obtained when all the DMD pixels are open. Although only half of the DMD pixels are turned on in the optimal mask (i.e. only half of the intensity of the incident light reached on the scattering medium), the photoacoustic signal generated by the optimal mask is still stronger than the photoacoustic signal when all the DMD pixels are opened. The main cause is that the optimal mask selected the segments which added constructively at the target point30. The enhancement (7.83) obtained in our experiments is very close to the theoretical enhancement (12.27), owing to our high signal-to-noise ratio photoacoustic signals. Figure 6(b) shows the evolution curve of the averaged fitness value of each generation in the optimization process. The red line represents the experimental results obtain by the method we proposed which combines the wavelet denoising with the correlation detection, while the blue line indicates that only the data averaging method is used to improve the SNR. Figure 6(c,d) show the speckle patterns captured by the CCD before and after optimization during the optimization process of Fig. 6(a). We present the waveforms of two typical generations in two evolutionary processes (Fig. 7). As expected, due to the lower SNR and the influence of clutters, the enhancements obtained with the averaging method are unsatisfactory.
During the experiment, we noticed that although the waveforms of the photoacoustic signals before and after the optimization are similar, there are still some differences between different generations. This may have a negative effect on our correlation detection method. Therefore, we used the photoacoustic signal obtained during each iteration as the correlation detection template for the next acquisition of the photoacoustic signal. This maximizes the assurance that each time what participates in the iteration is the photoacoustic signal received by the ultrasonic transducer instead of the noise.
Figure 7(a,b) show the photoacoustic signals acquired at the 10th and 70th generations in the evolutionary process shown in Fig. 6 (red line) that used wavelet denoising and correlation detection method. Figure 7(c,d) show the photoacoustic signals acquired at the 10th and 70th generations of the evolutionary process shown in Fig. 6(b) (blue line) that without wavelet denoising and correlation detection. As shown in Fig. 7, when the wavelet denoising and correlation detection methods is not used, the enhancement of the photoacoustic signal is relatively low due to the poor SNR and clutters. The wavelet denoising and correlation detection methods proposed by us not only improves the SNR of the photoacoustic signal but also effectively filters out the clutters.
We have further actualized two-point focusing experiment with two absorbers. Since the photoacoustic signals from different target points reaches the transducer at different times and our ultrasonic transducers have a large focal region, we can simultaneously receive the photoacoustic signals from multiple absorbers. Figure 8(a) shows a phantom containing two target absorbers. Both absorbers are made of the 150 μm diameter black nylon thread and embedded in an agarose gel. The absorber was placed 3 cm behind the scattering sample, and the two absorbers are separated by 500 μm. As in the case of single absorber, the pulsed laser first passed through the scattering medium – ground glass before it irradiated onto the agarose gel.
Figure 8 shows that two-point focusing results in lower signal enhancement due to the enlargement under the absorption area. The photoacoustic signals of the optimal masks for the two absorbers were respectively 3.7 and 2.4 times stronger than the photoacoustic signals under the random masks. Theoretically, as shown in Eq. 4, the enhancement of photoacoustic signal for two-point focusing experiment should be half of the single-point focusing enhancement, i.e. 6.135. The difference in the enhancement of the photoacoustic signals for the two absorbers is mainly due to the sensitivity of the ultrasonic transducer varies in the focal region16.
Discussion and Conclusions
In the experiment we used an ultrasonic transducer with a low center frequency (5 MHz). Lower frequency result in a larger ultrasound focal region, which increases the number of speckle patterns within the ultrasound focal region. Then, the enhancement of the photoacoustic signal becomes lower. However, large ultrasound focal region allows us to obtain the feedback signals of multiple absorbers. In addition, lower frequency photoacoustic waves experience less attenuation in living tissues, which is of great significance in further increasing light focusing depth with photoacoustic method13.
The application of DMD makes it possible to achieve fast light focusing by photoacoustic wavefront shaping. However, for the photoacoustic wavefront shaping, the DMD can withstand low-energy pulse laser which further reduces the SNR of the photoacoustic signals. The method we proposed in this paper which combines wavelet denoising and correlation detection can effectively improve the SNR of the photoacoustic signals and has no need to acquisition of a large number of photoacoustic signals for averaging.
The overall focusing speed depends on the acquisition time of a single photoacoustic signal and the total duration of the optimization15. The single photoacoustic signal processing time of the proposed method is about 50 ms, which is mainly limited by the computing speed of the computer. Therefore, with a better performing computer or FPGA, the processing time can be shortened andbecomes more promising for living tissues with short decorrelation time29. Our focusing experiments takes 30 minutes, which are mainly limited by the repetition rate of the pulsed laser (10 Hz). These are not fundamental restrictions. Faster photoacoustic wavefront shaping can be achieved with our method using a higher repetition rate pulsed laser and a higher speed calculator.
We propose a method to enhance the SNR of the photoacoustic signals in photoacoustic wavefront shaping, which can be used to extract and denoise photoacoustic signals deeply buried in noise. Compared with previous work, our method focus quickly (30 minutes) using a low repetition rate pulse laser. Our method is simple and does not require any additional expensive experimental equipment or complicated signal processing circuits. The experiments demonstrated that our method increased the SNR of the photoacoustic signals from the average value 3.86 to 25.2, which increases nearly 6.5 times. High SNR of the photoacoustic feedback signals can not only improve the focusing speed of the wavefront shaping, but also improve the intensity of the focus. Using a binary amplitude modulation device (DMD), we achieved relatively high photoacoustic signal enhancement (7.83 times). In addition, benefit from improved SNR, we achieved simultaneous multipoint focusing with low frequency ultrasound transducer, and the two photoacoustic signals enhanced 3.7 and 2.4 times respectively.
The proposed method can effectively identify the photoacoustic signals from white noise and clutters, but when the white noise is too serious (SNR ≈ 1), the signal is completely submerged by noise, and wavelet denoising becomes ineffective. In this case, the method that extract the signal from the white noise first with the frequency domain filtering method and then eliminate the influence of the clutters which overlap with the photoacoustic signal in the frequency domain with the correlation detection algorithm may be feasible.
In order to improve the optimization result, we selected the speckle grain similar to the size of the absorber. In biological tissues, we are unable to control the speckle grains size. Smaller speckle grains size will result in an increase in the number of speckle grains that are irradiated onto the absorber. This requires more DMD blocks to increase the controllable degrees of freedom, or the optimization effect will go unsatisfactory. However, higher controllable degrees of freedom mean longer optimization time. As the speckle size becomes smaller, it may occur that a multiple of optimized speckles appear in the area where the ultrasonic focusing region overlaps with the absorber. This problem can be solved using the nonlinear photoacoustic effect31. Wavefront shaping methods based on non-linear photoacoustic effect have no requirement for speckle size. Due to the non-linear response of the absorber, a focus containing only one speckle grain will be formed in the ultrasound focal region after optimization. The signal acquisition and detection method proposed in this paper is equally effective for nonlinear photoacoustic wavefront shaping.
The method we proposed has great advantages in the case of low SNR photoacoustic signals. It can effectively extract and denoise the photoacoustic signals and is widely applicable to general photoacoustic imaging and photoacoustic wavefront shaping. The use of genetic algorithm further enhances the robustness of the method, which is extremely important for its application in living tissues.
Acknowledgements
The authors acknowledge the support of the National Key Research and Development Program of China under Grant No. 2017YFB1104500, the Natural Science Foundation of Beijing under Grant No. 7182091, the National Natural Science Foundation of China under Grant No. 21627813, and the Fundamental Research Funds for the Central Universities under Grant No. PYBZ1801.
Author Contributions
Must include all authors, identified by initials, for example: J. Sun, Y. Ding, H. He and Q. Liu conceived the experiments, J. Sun, B. Zhang and Q. Feng conducted the experiments, J. Sun analysed the results. All authors reviewed the manuscript.
Competing Interests
The authors declare no competing interests.
Footnotes
Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Contributor Information
Yingchun Ding, Email: dingyc@mail.buct.edu.cn.
Qiang Liu, Email: qiangliu@mail.tsinghua.edu.cn.
References
- 1.Liang X, Boppart SA. Biomechanical properties of in vivo human skin from dynamic optical coherence elastography. IEEE Transactions on Biomedical Engineering. 2010;57:953–959. doi: 10.1109/TBME.2009.2033464. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Dilworth DS, Leith EN, Lopez JL. Three-dimensional confocal imaging of objects embedded within thick diffusing media. Applied Optics. 1991;30:1796–803. doi: 10.1364/AO.30.001796. [DOI] [PubMed] [Google Scholar]
- 3.Ntziachristos V. Going deeper than microscopy: the optical imaging frontier in biology. Nature Methods. 2010;7:603–14. doi: 10.1038/nmeth.1483. [DOI] [PubMed] [Google Scholar]
- 4.Vellekoop IM, Mosk AP. Focusing coherent light through opaque strongly scattering media. Optics Letters. 2007;32:2309. doi: 10.1364/OL.32.002309. [DOI] [PubMed] [Google Scholar]
- 5.Blochet B, Bourdieu L, Gigan S. Focusing light through dynamical samples using fast continuous wavefront optimization. Optics Letters. 2017;42:4994–4997. doi: 10.1364/OL.42.004994. [DOI] [PubMed] [Google Scholar]
- 6.Haowen, R., Mooseok, J. & Yang, C. Optical focusing inside scattering media with time-reversed ultrasound microbubble encoded light. Nature Communications6, 8968 (2015). [DOI] [PMC free article] [PubMed]
- 7.Vellekoop IM, Lagendijk A, Mosk AP. Exploiting disorder for perfect focusing. Nature Photonics. 2010;4:320–322. doi: 10.1038/nphoton.2010.3. [DOI] [Google Scholar]
- 8.Popoff SM, et al. Measuring the transmission matrix in optics: an approach to the study and control of light propagation in disordered media. Physical Review Letters. 2010;104:100601. doi: 10.1103/PhysRevLett.104.100601. [DOI] [PubMed] [Google Scholar]
- 9.Xu X, Liu H, Wang LV. Time-reversed ultrasonically encoded optical focusing into scattering media. Nature Photonics. 2011;5:154. doi: 10.1038/nphoton.2010.306. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Kong F, et al. Photoacoustic-guided convergence of light through optically diffusive media. Optics Letters. 2011;36:2053–5. doi: 10.1364/OL.36.002053. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Lai P, Xu X, Liu H, Wang LV. Time-reversed ultrasonically encoded optical focusing in biological tissue. Journal of Biomedical Optics. 2012;17:030506. doi: 10.1117/1.JBO.17.3.030506. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Wang YM, Judkewitz B, Dimarzio CA, Yang C. Deep-tissue focal fluorescence imaging with digitally time-reversed ultrasound-encoded light. Nature Communications. 2012;3:928. doi: 10.1038/ncomms1925. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Xu M, Wang LV. Photoacoustic imaging in biomedicine. Review of Scientific Instruments. 2006;77:305–598. [Google Scholar]
- 14.Chaigne T, et al. Controlling light in scattering media non-invasively using the photoacoustic transmission matrix. Nature Photonics. 2013;8:58–64. doi: 10.1038/nphoton.2013.307. [DOI] [Google Scholar]
- 15.Tzang O, Piestun R. Lock-in detection of photoacoustic feedback signal for focusing through scattering media using wave-front shaping. Optics Express. 2016;24:28122. doi: 10.1364/OE.24.028122. [DOI] [PubMed] [Google Scholar]
- 16.Conkey DB, et al. Super-resolution photoacoustic imaging through a scattering wall. Nature Communications. 2015;6:7902. doi: 10.1038/ncomms8902. [DOI] [PubMed] [Google Scholar]
- 17.Tay JW, Liang J, Wang LV. Amplitude-masked photoacoustic wavefront shaping and application in flowmetry. Optics Letters. 2014;39:5499–502. doi: 10.1364/OL.39.005499. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Peng Z, Wang G. Study on optimal selection of wavelet vanishing moments for ecg denoising. Scientific Reports. 2017;7:4564. doi: 10.1038/s41598-017-04837-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Abbasion S, Rafsanjani A, Farshidianfar A, Irani N. Rolling element bearings multi-fault classification based on the wavelet denoising and support vector machine. Mechanical Systems and Signal Processing. 2007;21:2933–2945. doi: 10.1016/j.ymssp.2007.02.003. [DOI] [Google Scholar]
- 20.Ching PC, So HC, Wu SQ. On wavelet denoising and its applications to time delay estimation. IEEE Transactions on Signal Processing. 1999;47:2879–2882. doi: 10.1109/78.790670. [DOI] [Google Scholar]
- 21.Vidakovic B, Lozoya CB. On time-dependent wavelet denoising. Signal Processing IEEE Transactions on. 1998;46:2549–2554. doi: 10.1109/78.709544. [DOI] [Google Scholar]
- 22.Qiu H, Lee J, Lin J, Yu G. Wavelet filter-based weak signature detection method and its application on rolling element bearing prognostics. Journal of Sound and Vibration. 2006;289:1066–1090. doi: 10.1016/j.jsv.2005.03.007. [DOI] [Google Scholar]
- 23.Ngui, W. K., Leong, M. S., Hee, L. M. & Abdelrhman, A. M. Wavelet analysis: mother wavelet selection methods. In Applied mechanics and materials, vol. 393, 953–958 (2013).
- 24.Chaigne, T. Control of scattered coherent light and photoacoustic imaging: toward light focusing in deep tissue and enhanced, sub-acoustic resolution photoacoustic imaging. Ph.D. thesis, Paris 6 (2016).
- 25.Donoho DL, Johnstone JM. Ideal spatial adaptation by wavelet shrinkage. biometrika. 1994;81:425–455. doi: 10.1093/biomet/81.3.425. [DOI] [Google Scholar]
- 26.Chiu C, Lin T, Liau B. Using correlation coefficient in ecg waveform for arrhythmia detection. Biomedical Engineering Applications Basis and Communications. 2005;17:0500023–. doi: 10.4015/S1016237205000238. [DOI] [Google Scholar]
- 27.Conkey DB, Brown AN, Caravaca-Aguirre AM, Piestun R. Genetic algorithm optimization for focusing through turbid media in noisy environments. Optics Express. 2012;20:4840–9. doi: 10.1364/OE.20.004840. [DOI] [PubMed] [Google Scholar]
- 28.Feng Q, Zhang B, Liu Z, Lin C, Ding Y. Research on intelligent algorithms for amplitude optimization of wavefront shaping. Applied Optics. 2017;56:3240. doi: 10.1364/AO.56.003240. [DOI] [PubMed] [Google Scholar]
- 29.Wang D, et al. Focusing through dynamic tissue with millisecond digital optical phase conjugation. Optica. 2015;2:728–735. doi: 10.1364/OPTICA.2.000728. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Akbulut D, Huisman TJ, Putten EGV, Vos WL, Mosk AP. Focusing light through random photonic media by binary amplitude modulation. Optics Express. 2011;19:4017. doi: 10.1364/OE.19.004017. [DOI] [PubMed] [Google Scholar]
- 31.Lai, P., Wang, L., Jian, W. T. & Wang, L. V. Nonlinear photoacoustic wavefront shaping (paws) for single speckle-grain optical focusing in scattering media. Physics (2014).