Skip to main content
Nature Communications logoLink to Nature Communications
. 2019 Mar 19;10:1343. doi: 10.1038/s41467-019-09240-8

Author Correction: Strong indirect coupling between graphene-based mechanical resonators via a phonon cavity

Gang Luo 1,2,#, Zhuo-Zhi Zhang 1,2,#, Guang-Wei Deng 1,2,, Hai-Ou Li 1,2, Gang Cao 1,2, Ming Xiao 1,2, Guang-Can Guo 1,2, Lin Tian 3,, Guo-Ping Guo 1,2,
PMCID: PMC6423086  PMID: 30886149

Correction to: Nature Communications 10.1038/s41467-018-02854-4; published online 26 January 2018

The original version of this Article contained an error in the last sentence of the second paragraph of the ‘Raman-like coupling between well-separated resonators’ section of the Results, which incorrectly read ‘On the contrary, when the detuning Δ12 is lowered to ~180 kHz, a distinct avoided level crossing between modes R1 and R3 is observed, as shown inside the dashed circle in Fig. 2b.’ The correct version states ‘Δ12/2π’ in place of ‘Δ12.’

Additionally, the first sentence of the ‘Theory of three-mode coupling’ section of the Methods originally incorrectly read ‘We describe this three-mode system with the Hamiltonian (ħ = 4).’ The correct version states ‘ħ = 1’ instead of ‘ħ = 4’.

Equation 8 was originally missing a factor of ‘a2’ from the second term, and incorrectly read:

aΔ±=(Ω12a1±ωΔ0Δ+Ω23a3)2ωΔ0(ωΔ0Δ).

The correct form of Equation 8 is:

aΔ±=(Ω12a1±ωΔ0Δa2+Ω23a3)2ωΔ0(ωΔ0Δ).

The eleventh and twelfth sentences of the second paragraph of the ‘Theory of three-mode coupling’ section of the Methods originally incorrectly read ‘The nearly degenerate modes can be viewed as a hybridization of α1 and α3 with an effective coupling Ω13α1α3+α3α12. The magnitude of this effective coupling is equal to the frequency splitting between the nearly degenerate modes, with Ω3=(Ω122+Ω232)2Δ.’ These sentences have been replaced with ‘The nearly degenerate modes can be viewed as a hybridization of α1 and α3 with an effective splitting (Ω122+Ω232)2Δ.’

In Equation 10, the term on the left-hand side was originally incorrectly given as ‘M’. The corrected version changes this to ‘Meff’.

Finally, the original version of this Article contained an error in Fig. 3b, in which the units on the y-axis were incorrectly given as ‘MHz’, rather than the correct ‘kHz’.

This has been corrected in both the PDF and HTML versions of the Article.

Contributor Information

Guang-Wei Deng, Email: gwdeng@ustc.edu.cn.

Lin Tian, Email: ltian@ucmerced.edu.

Guo-Ping Guo, Email: gpguo@ustc.edu.cn.


Articles from Nature Communications are provided here courtesy of Nature Publishing Group

RESOURCES