Erratum: Measuring temporal stability of positron emission tomography standardized uptake value bias using long-lived sources in a multicenter network

Darrin Byrd a, Rebecca Christopfel a, Grae Arabasz b, Ciprian Catana b, Joel Karp c, Martin A Lodge d, Charles Laymon e, Eduardo G Moros f, Mikalai Budzevich f, Sadek Nehmeh g, Joshua Scheuermann c, John Sunderland h, Jun Zhang i, Paul Kinahan a
PMCID: PMC6441995  PMID: 30944844

Abstract.

This erratum corrects an error in “Measuring temporal stability of positron emission tomography standardized uptake value bias using long-lived sources in a multicenter network,” by D. Byrd et al.


This article [J. Med. Imag. 5(1), 011016 (2018), doi: 10.1117/1.JMI.5.1.011016] was originally published online on 4 January 2018 with the following error. The Pearson correlation coefficients were not computed and reported in a consistent fashion, most notably in Table 10, where values labeled “r2” were instead the values of r without appropriate squaring. Figure 8 contained a similar inconsistency, though not all values were affected.

Original (erroneous) and corrected correlation coefficients from Table 10 are enlisted here with their corresponding measurements:

Original (erroneous) Corrected
Measurements Correlation coefficient Measurements Correlation coefficient r2
12 0.966 12 0.934
12 0.956 12 0.915
10 0.934 10 0.872
7 0.867 7 0.752
10 0.583 10 0.340
20 0.993 20 0.985
15 0.851 15 0.725
8 0.866 8 0.749
15 0.378 15 0.143
6 0.976 6 0.953
8 0.594 8 0.353
3 0.387 3 0.150
8 0.944 8 0.892
10.3±4.3 0.792±0.216 11 0.002
    10.4±4.2 0.626±0.337

The original and the corrected Figure 8 are depicted below:

Original

graphic file with name JMI-006-019801-g001.jpg

Corrected

graphic file with name JMI-006-019801-g002.jpg

This article was corrected online on 23 March 2019. It appears correctly in print.