Abstract
Untargeted analysis of a composite house dust sample has been performed as part of a collaborative effort to evaluate the progress in the field of suspect and nontarget screening and build an extensive database of organic indoor environment contaminants. Twenty-one participants reported results that were curated by the organizers of the collaborative trial. In total, nearly 2350 compounds were identified (18%) or tentatively identified (25% at confidence level 2 and 58% at confidence level 3), making the collaborative trial a success. However, a relatively small share (37%) of all compounds were reported by more than one participant, which shows that there is plenty of room for improvement in the field of suspect and nontarget screening. An even a smaller share (5%) of the total number of compounds were detected using both liquid chromatography–mass spectrometry (LC-MS) and gas chromatography–mass spectrometry (GC-MS). Thus, the two MS techniques are highly complementary. Most of the compounds were detected using LC with electrospray ionization (ESI) MS and comprehensive 2D GC (GC×GC) with atmospheric pressure chemical ionization (APCI) and electron ionization (EI), respectively. Collectively, the three techniques accounted for more than 75% of the reported compounds. Glycols, pharmaceuticals, pesticides, and various biogenic compounds dominated among the compounds reported by LC-MS participants, while hydrocarbons, hydrocarbon derivatives, and chlorinated paraffins and chlorinated biphenyls were primarily reported by GC-MS participants. Plastics additives, flavor and fragrances, and personal care products were reported by both LC-MS and GC-MS participants. It was concluded that the use of multiple analytical techniques was required for a comprehensive characterization of house dust contaminants. Further, several recommendations are given for improved suspect and nontarget screening of house dust and other indoor environment samples, including the use of open-source data processing tools. One of the tools allowed provisional identification of almost 500 compounds that had not been reported by participants.
Electronic supplementary material
The online version of this article (10.1007/s00216-019-01615-6) contains supplementary material, which is available to authorized users.
Keywords: House dust, Suspect and nontarget analysis, Collaborative trial, Complementary analytical techniques, Mass spectrometry
Introduction
The indoor environment is increasingly gaining attention as an important source of human exposure to environmental contaminants including pesticides, polybrominated diphenyl ethers (PBDEs), polycyclic aromatic hydrocarbons (PAHs), plasticizers, organophosphorus flame retardants, bisphenols, parabens, and other chemicals of concern for human health [1–7]. Pollution in the indoor environment is believed to contribute to a range of adverse effects, including respiratory diseases, cancer, and neuropsychological disorders [8–10]. Although dust is one of the most frequently studied matrices in the indoor environment, due to its complexity, analysis is almost exclusively limited to targeted analyses. Rapid development of new building materials, furnishings, and consumer products and lower air exchange rates for improved energy efficiency can be the factors increasing the accumulation of contaminants in indoor environments. It is anticipated that household dust should be further examined for the presence of other chemicals of human health concern to provide a more complete understanding of chemical exposure indoors. House dust is considered as an important exposure medium, in particular for infants and toddlers, who are at highest risk owing to hand-to-mouth activities. It is thought that the ingestion of settled dust may constitute a significant part of the exposure to some phthalates [11], polybrominated diphenyl ethers [12], and pesticides [13]. Hence, settled dust could be a global indicator of residential contamination, in particular for semivolatile and nonvolatile contaminants, and studies of household dust can be considered as an early warning system of environmental contamination. The screening of contaminants in dust facilitates the identification of new environmental hazards much earlier than through screening of ambient (outdoor) environmental matrices, where dispersion tends to reduce contaminant concentrations. Searching for unknown and even unanticipated chemicals requires a nontargeted analytical approach. So far, the field of suspect and nontarget screening is rapidly expanding, with examples of successful application, e.g., for emerging contaminants in water samples [14–18], but its application to the indoor environment was rather limited with some successful applications reported only recently [19–22].
In response to the growing interest in further development and harmonization of suspect and nontarget screening approaches and their application to the indoor environment, the NORMAN network (Network of reference laboratories, research centres and related organisations for monitoring of emerging environmental substances) organized a collaborative nontarget screening trial on composite household dust. Each participating organization was requested to analyze the test sample using established mass spectrometry (MS) techniques in their laboratory, declare a number of substances present in the sample, and perform provisional identification using target, suspect, and nontarget screening approaches. Together with the test sample, mixtures of analytical standards suitable for liquid chromatography (LC) and gas chromatography (GC), respectively, were provided for the calculation of retention time index (RTI) and retention index (RI) information. RIs have a significant role in nontarget screening as they can be used to support or reject a candidate structure. In future studies, suspect lists with associated RIs will have a great value, e.g., in retrospective screening of compounds of emerging concern using data stored in digital archives.
The study aimed to (a) evaluate progress in the field of suspect and nontarget screening of dust, (b) build an extensive database of semivolatile and nonvolatile organic contaminants that could be applied in future screening of the indoor environment, (c) assess the degree of complementarity of instrumental analytical techniques, and (d) present recommendations for successful suspect and nontarget screening. To our knowledge, this is the first collaborative effort on untargeted analysis of indoor dust.
Materials and methods
Description of the samples and participation in the trial
All dust samples were obtained from a larger, homogenized dust sample, which was a composite of residential dust obtained from household vacuum bags collected from homes around Toronto, Canada, in 2015. The dust was preprocessed by sieving with a coarse 1-mm sieve to aid in homogenization and stored at − 18 °C. The dust sample was collected to be used in another interlaboratory study aimed at halogenated flame-retardant contaminants in indoor dust and has been checked for homogeneity. Aliquots of 250 mg of the dust were transferred to brown glass vials that were dispatched in January 2016 with standard mixtures for use in the calculation of retention index information: alkane standards for GC-MS techniques and 10 substances for LC-MS techniques (Electronic supplementary material (ESM) Table S1a). In addition, participants were later requested to analyze two additional standard mixtures, for negative electrospray ionization (ESI) and positive ESI, respectively, each of them containing 18 substances (ESM Table S1b) to facilitate quantitative structure–retention relationship (QSRR)-based prediction of retention times of unknown compounds.
All participants were requested to measure these standards and report the results by June 2016. The reporting was done using data collection templates that included details related to the chromatographic and mass spectrometric methods and related to the reported compounds, e.g., retention time (RT), m/z, intensity, intensity of blank, MS/MS data, type of workflow, proposed ID, molecular formula, CAS, and identification confidence level. Twenty-seven participants from 26 organizations representing 15 countries registered to participate in the study. Seventeen participants registered for LC-MS and GC-MS techniques, three only for the GC-MS, and seven for LC-MS only. Out of these, 20 datasets were received for the LC-MS techniques and 14 for the GC-MS techniques. One participant officially withdrew from the trial for both techniques and one for the GC-MS technique only. The participants’ list included institutions with various levels of experience in performing suspect and nontarget methods (i.e., some were performing nontarget analysis for the first time, while others were more experienced). Table 1 shows a summary of the contributions received.
Table 1.
Code | Region | GC-MS or LC-MS | Total number of compounds | Number of compounds | Self-reported workflow | |||
---|---|---|---|---|---|---|---|---|
LC-MS | GC-MS | Target (%) | Suspect (%) | Nontarget (%) | ||||
Lab 1 | Asia-Pacific, N. America | Both | 591 | 457 | 134 | 6 | 5 | 89 |
Lab 2 | Europe | Both | 583 | 49 | 534 | 2 | 6 | 92 |
Lab 3 | Asia-Pacific, N. America | GC-MS | 525 | – | 525 | 0 | 0 | 100 |
Lab 4 | Asia-Pacific, N. America | Both | 417 | 271 | 146 | 15 | 14 | 78 |
Lab 5 | Europe | Both | 415 | 293 | 122 | 0 | 2 | 98 |
Lab 6 | Europe | LC-MS | 337 | 337 | – | 25 | 75 | 0 |
Lab 7 | Europe | Both | 287 | 57 | 230 | 1 | 11 | 88 |
Lab 8 | Asia-Pacific, N. America | Both | 216 | 25 | 191 | 29 | 19 | 52 |
Lab 9 | Europe | Both | 211 | 28 | 183 | 15 | 11 | 74 |
Lab 10 | Europe | Both | 122 | 77 | 45 | 19 | 26 | 55 |
Lab 11 | Asia-Pacific, N. America | LC-MS | 121 | 121 | – | 0 | 0 | 100 |
Lab 12 | Europe | LC-MS | 186 | 186 | – | 3 | 0 | 97 |
Lab 13 | Europe | Both | 180 | 143 | 37 | 0 | 0 | 100 |
Lab 14 | Europe | LC-MS | 77 | 77 | – | 0 | 58 | 42 |
Lab 15 | Europe | LC-MS | 69 | 69 | – | 38 | 48 | 14 |
Lab 16 | Europe | Both | 68 | 21 | 47 | 22 | 1 | 76 |
Lab 17 | Europe | Both | 57 | 46 | 11 | 91 | 0 | 9 |
Lab 18 | Asia-Pacific, N. America | Both | 55 | 29 | 26 | 100 | 0 | 0 |
Lab 19 | Europe | LC-MS | 40 | 40 | – | 0 | 0 | 100 |
Lab 20 | Asia-Pacific, N. America | Both | 23 | 12 | 11 | 4 | 9 | 87 |
Methods and workflows used for LC-MS and GC-MS analysis
Extraction
The participants were instructed to use dichloromethane for extraction of dust for GC-MS analysis and dichloromethane:methanol (1:9, v/v) for extraction of dust for LC-MS analysis. The extraction technique and cleanup techniques were not specified, but all laboratories were requested to process a procedural blank in parallel to the sample.
LC-HRMS
An overview of LC-HRMS(MS) methods is presented in ESM Table S2 and Table S3. Most participants used C18 reversed phase columns with medium or very long UHPLC gradients. One of the 20 LC participants used a biphenyl column and one used a serial coupling of zwitterionic hydrophilic interaction (HILIC) and reversed phase (RP) chromatography (LC-LC). The solvent was typically water/methanol or water/acetonitrile (isopropanol as a second organic solvent in one case), either neat or with typical modifiers (e.g., formic acid or ammonium acetate/formate/fluoride). Between 2 and 35 μl of the extract was injected.
ESI was mainly used with different collision-induced dissociation (CID) or higher-energy CID (HCD) energies. Some participants submitted MS data only. One participant used atmospheric pressure chemical ionization (APCI) and atmosphere pressure photoionization (APPI) in addition to ESI. All participants who measured in both positive and negative ESI modes did so in separate runs. Some participants used “all-ion” data-independent acquisition approaches (fragmentation without precursor ion selection).
Most participants used time-of-flight (TOF), quadrupole TOF (QTOF), or ion mobility QTOF mass analyzers. Three used Orbitrap mass analyzers. The resolution of the TOF-based systems ranged from 10,000 to 42,000 and the resolution of the Orbitrap systems from 70,000 to 120,000.
In general, the most commonly used workflows consisted of peak-picking and deconvolution by instrument vendor software and spectra matching to commercially available or in-house mass spectral libraries. One participant used open-source XCMS [23] and R-packages, while another used the STOFF-IDENT open source platform [24]. MetFrag [25] was a popular tool used by many participants for prediction of MS/MS fragmentation. Two participants used correlation RT vs. logD to facilitate molecule identification.
GC-MS
An overview of GC-MS methods is presented in ESM Table S4 and Table S5. Most participants used nonpolar capillary columns coated with 5% phenyl polydimethylsiloxane or 5% phenyl dimethylarylene siloxane. One was using a 100% polymethylsiloxane column, and the remaining were using selectivity-tuned nonpolar columns (PAH, volatiles, EPA 1614). Two participants applied GC×GC, both using 50% phenyl columns for the second-dimension separation. All participants used hydrogen or helium as the carrier gas and all used total sample transfer techniques (splitless, PTV, or on-column injection). Roughly half the participants used speed optimized programs (6–10 °C/min) and the other half used efficiency-optimized oven temperature programs (2–5 °C/min). The former were generally employing target analysis workflows and the latter suspect and nontarget screening workflows.
A range of MS analyzers were used. The most popular were (Q)TOF analyzers, used by half of the participants, followed by triple-quadrupole (QQQ) and single-quadrupole analyzers, used by four and three participants, respectively. One data contributor used a GC-Orbitrap system. Most of the GC-(Q)TOFs were HRMS systems, ranging widely in age and performance. The reported mass resolution ranged from 5000 to 60,000 and the mass accuracy from 5 to 20 ppm, with one exception at 200 ppm. The remaining instruments were low-resolution mass spectrometers (LRMS) that provide unit mass resolution. Electron ionization (EI) was by far the most common ionization technique, used by all but one participant. Complementary data were generated in chemical ionization (CI) and APCI mode by four and two participants, respectively.
The most common suspect and nontarget screening workflow was peak-picking, EI library search (NIST and in-house libraries), manual spectra review, and (sometimes) interpretation. Several participants used peak and spectra deconvolution algorithms (PARAFAC, AMDIS, and similar) to enhance spectra quality. Some of these labs also used RI matching (NIST or in-house databases) to increase confidence in their identification. In the absence of RI data, at least one participant utilized RT correlation (RT vs. molecular weight) to check the plausibility of proposed structures. Additional information on the workflows and libraries used by each laboratory is given in Tables S3 and S5 of the ESM.
Data curation
In nontarget screening, there is a clear risk for misassignment, especially for compound classes that produce very similar spectra and for compounds that do not produce strong molecular ion signals. The latter may, for instance, occur in LC-MS for compounds that easily produce stable adducts (and no molecular ions) and in GC-MS for compounds that easily fragment. Thus, proper data curation is essential to reduce the number of misassigned compounds that are added to the final list of compounds found in the house dust sample and to the indoor dust contaminant suspect list.
The level of data curation varied between the participants in the collaborative trial. Many participants applied in-house rules (basic to elaborate) for qualifying sample constituents for reporting and provided good documentation on what had been done. In several reported results, there were indications that some compounds had been misassigned, e.g., the same compound reported several times with different retention times, GC analyses with low molecular weight compounds reported with high retention indices, etc. It was therefore deemed necessary to perform additional curation of the reported data.
Expert evaluation of submitted LC-HRMS spectra and experimental or predicted RTI information were used to curate the contaminants found through suspect and nontarget screening analyses, thereby increasing the identification confidence.
Results and discussion
Curation of LC-MS data
Curation of the LC-MS data consisted of several steps. Only 50% volunteered to submit their raw chromatograms for further expert evaluation. Whenever MS/MS data were available for compounds reported with identification confidence level 3 or lower [26], and the participant did not include library searching in their workflow, a library search (MassBank, NIST, and Agilent commercial PCDL libraries) was performed. If no experimental spectra were available, MetFrag [25, 27] or CFM-ID [28] was used to predict possible MS/MS fragments of the reported compound. If the compound spectrum was found to agree with the library or in silico spectrum (minimum three fragments matching), it was added to the list of dust contaminants and was assigned identification confidence level 3. For example, one participant reported sorbitol monostearate, tri-xylenyl phosphate, ethyltriacetoxysilane, 2,2-dihydroxy-4,4-dimethoxy-benzophenone, acrylic acid, acrylic acid 2-ethylhexyl ester copolymer, phtalic acid divinyl ester, gallic acid propyl ester, tert-butyl-4-hydroxyanisole, and diacetoxy-di-tert-butoxysilane at level 4 confidence. However, the reported MS/MS spectra did not match the library or in silico spectra, and thus, those structures were likely incorrectly assigned and therefore were not included in the list of dust contaminants.
In the next step, data from participants that did not report MS/MS data were evaluated. Those results stem from suspect screening using exact mass (pseudo-molecular ion) information, which is error prone (i.e., high false-positive rate), unless carefully evaluated. To support such curation, calculated RTIs were employed. Two sets of calibration standards were used for indexing the LC-MS data. The first set was used as calibrants for QSRR models for RTI prediction, as described by Aalizadeh et al. [29]. The second set was used to establish a RTI/logD correlation within the FOR-IDENT platform (hosted at the Technical University of Munich, Germany) for compounds in the STOFF-IDENT database (Bavarian Environment Agency and the University of Applied Sciences Weihenstephan-Triesdorf, Germany). These resources may be found at https://www.lfu.bayern.de/stoffident and https://water.for-ident.org [24, 30]. In the FOR-IDENT processing workflow, the RTs of the candidate compounds are used to estimate their normalized retention time and thus correlated logD values (at a specific pH value). These observed logD values are then compared with the logD values for those molecules stored in the compound database STOFF-IDENT (ΔlogD). In addition, in cases where alternative compounds with the same empirical formula are present in the STOFF-IDENT database, their ΔlogD will also be calculated and all compounds will be ranked (original candidate and alternative compounds) in FOR-IDENT. Table S6 (see ESM) illustrates the application of RTI in the identification of some emerging contaminants reported by 12 participants, while ESM Table S7 shows an example of using ΔlogD in FOR-IDENT platform for data curation.
A useful application of RTI is to remove false positives from the list of identified compounds. A compound is considered as false positive if it gives high residuals (error between predicted and experimental RTIs), while its structure belongs inside the application domain of the models, and the experimental RTI does not overlap with other participants or measurements. For participants that submitted calibration data for the FOR-IDENT platform and did not provide supporting evidence (i.e., no MS/MS, compounds not reported by other participants), all the compounds with a ΔlogD outside ± 0.7 were considered as potential false positives. Compounds that fall within the acceptance window were assigned identification confidence level 3.
We cannot exclude the possibility that the LC columns used by participants are considerably different from those used to create the prediction models, resulting in a larger ΔlogD. Fortunately, most laboratories in the current collaborative trial used LC columns similar to those used to create the model. However, some classes of compounds will undoubtedly lie outside the application domain of the predictive models. In such cases, the predictions are considered unreliable, but not necessarily wrong. This is illustrated by some of the surfactants, pentaethylene glycol, hexaethylene glycol, heptaethylene glycol, and octaethylene glycol that were reported by four participants. Although the structures were outside of the application domain of the RTI models, the RTIs on different LC systems were statistically equivalent and two participants reported the surfactants at identification confidence level 2a (mass spectra available in the library). Thus, those compounds were likely present in the dust. Less strict acceptance criteria should therefore be applied to this class of compounds.
Curation of GC-MS data
Alkanes were used for indexing of GC data. All participants used linear temperature programming, and therefore, the original Kovats equation (1958) was not applicable and the modified method by Van den Dool and Kratz [31] was used for calculation of linear retention indices (LRIs). These calculations were done by most of the participants. In the cases where no LRIs were reported, but retention time data for the alkanes was available, LRIs could still be calculated.
In a first round of data curation, the LRIs were correlated to the molecular weights of the reported dust contaminants. Compounds that were grossly deviating from the 1:1 line were removed. More than 100 compounds had to be removed and it was suspected that even more compounds were misassigned, but the regression model was too rough (r2 = 0.7 after removal of obvious outliers) to allow anything but a first rough curation. Attempts were made to improve the retention correlation model. A two-parameter regression model for LRIs vs. boiling points showed a stronger correlation, but there was still a considerable spread in data (r2 = 0.8). An Abraham general solubility model was therefore developed using Abraham constants from ACD labs Percenta software, with Absolve add-on (Toronto, Canada), and multiple linear regression (MLR) in Microsoft Excel. This model produced satisfactory results (r2 > 0.9) to allow recognition of suspected outliers. It proved difficult to set strict elimination criteria, mainly because some compound classes were poorly represented in the dataset and therefore likely outside the model domain. Potential outliers were therefore manually reviewed. A conservative approach was used, and compounds were only removed if there were strong reasons to do so, e.g., there was a large difference between the experimental and predicted LRIs and the compound was likely to be within the model domain.
A new Abraham model was constructed after elimination of compounds that were suspected to be misassigned. It exhibited a strong linear relationship with a slope close to 1 and an r2 of 0.96 (see Fig. 1). As can be seen, there were still compounds with LRIs deviating from the predicted LRIs, but those were generally target analytes or compounds that were reported by multiple laboratories (piperine, two glycols, HBCDD, and one organophosphate ester). There were some systematic deviations, e.g., cholesteryl benzoates were generally overestimated, and polyethylene glycols underestimated. In addition, all deviating compounds are likely to appear in indoor environments because they are constituents of food, personal care products, or building materials. The spread in the remaining LRI data is regarded as normal considering that the data was generated by multiple laboratories using a range of different nonpolar GC columns.
Compounds identified in house dust
Database of identified compounds
A compilation of the individual compounds that were identified or tentatively identified in house dust by the participants in the collaborative trial and that passed the data curation is provided in Microsoft Excel format as part of the ESM. The identification confidence level of each compound is given in the Excel file. Overall, nearly 2350 compounds were identified (18%) or tentatively identified (25% at confidence level 2 and 58% at confidence level 3). The compounds have been manually grouped based on origin (biogenic or anthropogenic), use category, or chemical class to aid a more detailed contaminant discussion. Figure 2 summarizes the major groups of contaminants found in house dust.
Compounds identified using LC-MS techniques
All participants using LC-MS techniques reported in total 969 compounds within the level of confidence 1–3 using the scale proposed earlier [26]. The contribution of individual participants was very variable between a few tens to several hundreds of compounds. Overall, only 59% of the reported compounds were identified or tentatively identified by more than one participant. Such differences most likely depend on the level of experience, time used for data evaluation, and probably factors such as access to libraries and suspect lists.
A wide range of different classes of compounds has been reported (Fig. 2) with glycols, phthalates, organophosphorus flame retardants, pharmaceuticals, biocides, and oxybenzone (UV-screen) being reported most frequently (5–10 times). Organophosphorus flame-retardant triphenyl phosphate (TPHP) and tris(2-butoxyethyl) phosphate (TBOEP) were the most frequently reported compounds by the LC-MS participants. TPHP is commonly found in target analyses of dust samples from different countries [32–37], and TBOEP is used in many indoor applications, for example, in plastics and floor polish [38].
Several biocides were reported and included imidacloprid, carbendazim, thiabendazole, and N,N-diethyl-m-toluamide (DEET). Imidacloprid is an insecticide belonging to the family of neonicotinoids. Carbendazim is a fungicide often used in house paints and plasterboards that continuously releases it into the environment. Together with imidacloprid, it was the most prevalent biocide in dust samples from Italy [39]. Thiabendazole is a fungicide used to control fruit and vegetable diseases such as mold, rot, blight, and stain. DEET is the most commonly used insect repellent and was previously reported as an indoor [1, 19] and outdoor air contaminant [40]. DEET is also detected in landfill leachate and drinking water [41].
Over 300 glycols and polyethylene glycol homologs (PEGs) have been detected with PEG-5 to PEG-16 being reported 5–10 times. PEGs are annually produced in millions of tons worldwide due to their broad use in cosmetics, plastic, water-soluble lubricants, pharmaceuticals, antifreeze agents, and nonionic surfactants [42].
Compounds identified using GC-MS techniques
The participants using GC-MS techniques reported in total 1281 compounds within the level of confidence 1–3 (Fig. 2). Most of the compounds (82%) were only reported by one participant. Many of these belong to the group of compounds that could not be assigned exact structure (because there were other positional isomers). Within the group of compounds that could be assigned exact structure and a CAS number, almost half (40%) were reported by more than one participant. For the remainder, the molecular formula and the backbone of the molecule could be established, but the exact location of the substituents was unknown, because the compounds had several positional isomers. For example, more than 450 medium chain–chlorinated paraffins were reported by one participant. The carbon chain length and degree of chlorination were known for all of them, but the carbon chain branching and chlorine substituent positions were unknown. Other compound classes with multiple positional isomers were PCBs and PBDEs (halogen position unknown), alkenes (double bond position unknown), branched alkanes and phthalates (branching unknown), and alkyl-substituted polycyclic aromatic hydrocarbons (alkyl-PAHs).
The reported compounds may be categorized into four major use/source categories accounting for 82% of all reported compounds: (1) persistent organic pollutants (POPs), (2) traffic-related compounds, (3) building material-related compounds, and (4) compounds related to pharmaceutical and personal care products (PPCPs). Persistent organic pollutants (medium chain polychlorinated paraffins (MCCPs), PCBs, PBDEs, and pesticides) accounted for 54% and traffic-related compounds (petroleum hydrocarbons, PAHs, and other PACs) for 25% of these compounds. The remaining compounds were distributed between building material and PPCP-related compounds, accounting for 11 and 9%, respectively.
Approximately 250 compounds did not fit into any of the major use categories and were therefore categorized according to chemical class. The major classes included: esters and ketones (23%), acids (17%), alcohols (15%), amides and amines (15%), aldehydes (15%), and miscellaneous compounds (14%).
The most frequently reported (i.e., 5–10 times) compounds belonged to plastics additives (22 compounds), PAHs (13 compounds), fatty acids (8 compounds), PPCPs (galaxolide, cetyl alcohol, and squalene), pesticides (permethrin and lambda-cyhalothrin), illicit drugs (cannabinol and delta-9-THC), and others (caffeine, cholesterol, vitamin E, and n-nonane).
The plastic additives included seven plasticizers (five phthalates, 2-ethylhexyl benzoate, and di-2-ethylhexyl adipate), seven organophosphate esters (TCEP, TCPP, TDCPP, TBP, TBEOP, TPHP, and EHDPP), six UV absorbers (benzophenone, oxybenzone, octyl salicylate, homosalate, octocrylene, and 2-ethylhexyl trans-4-methoxycinnamate), four polybrominated diphenyl ethers (BDE-47, BDE-99, BDE-100, BDE-153), and two antioxidants (BHT and 2,4-bis(1,1-dimethylethyl)phenol). Admittedly, some of the UV absorbers are also used in personal care products and could also have fallen into that category.
Compounds identified using both GC-MS and LC-MS techniques
There were few compounds reported by more than one participant, as mentioned before, and there was even a smaller share of the total number of compounds that were detected and reported by both LC-MS and GC-MS. Of the nearly 2400 tentatively identified compounds overall, only 5% were found by both techniques. The substances common to both platforms were predominantly fatty acids, glycols and polyethylene glycols, phthalates, and organophosphate esters. The remaining (minor) fraction measured by both platforms was as follows (in order of importance): amine/amides, pesticides, pharmaceuticals and illicit drugs, (nonphthalate) plasticizers, UV screens, PACs, and fragrances. Taken together, these data demonstrate that in order to comprehensively and holistically characterize contaminants in a complex matrix, such as house dust, it is necessary to use multiple LC-MS and GC-MS–based complementary analytical techniques.
Use of complementary chromatographic and mass spectrometric techniques and workflows for nontargeted analysis of house dust
While several studies have identified numerous nontarget compounds with LC-ESI-HRMS, this approach alone does not provide a comprehensive picture of chemical contamination. Specific classes of environmental contaminants cannot be analyzed by this method due to inefficient ionization or incomplete separation. Therefore, alternative and complementary separation and ionization methods need to be applied to expand the range of nontarget screening. GC-MS is a necessary complementary technique for nonpolar compounds. Two-dimensional gas chromatography–mass spectrometry (GC×GC-MS) has proven to be an efficient tool for effective nontarget screening (NTS) of nonpolar compounds in the environment [14, 15]. It was also successfully applied by participants in the collaborative trial. Further, application of GC-HRMS with soft ionization methods such as methane CI or APCI can provide valuable molecular ion information and enables the use of LC-HRMS type of identification workflows, thereby providing complementary information to the established GC-EI-MS workflows.
A breakdown of the (tentatively) identified compounds by the instrument platforms that have been applied by the participants in the collaborative trial is given in Fig. 3. It is clear that the use of four of the platforms (LC-ESI-MS, GC×GC-APCI-MS, GC×GC-EI-MS, and GC-EI-MS) has made a major contribution to the number of compounds identified in the house dust sample. A detailed discussion on the use of complementary separation and ionization techniques in LC-MS and GC-MS follows.
Complementary ionization techniques and workflows in LC-MS
A comprehensive chemical identification can be maximized by using multiple ionization sources, such as ESI, APCI, and APPI in positive and negative modes. ESI mainly ionizes relatively polar compounds, while APCI can be employed to ionize less polar molecules. APPI is relatively less popular and used for nonpolar compounds, which are poorly ionized by ESI and APCI. ESI is the most widely used ionization technique, and by combining ESI in positive mode and ESI in negative mode, most compounds in an extract can be ionized. Complementary use of APCI and APPI enables the analysis of additional compounds, not ionized by ESI.
All three ionization techniques were used by participants in the collaborative trial. ESI in positive and negative ion modes was the most popular technique and was used to tentatively identify the greatest number of compounds. One of the participants applied APCI and APPI (positive and negative modes) and found 13 and 9 compounds, respectively. However, there was considerable overlap between the compounds observed with the different ionization techniques, and eight compounds were detected using all three sources. APCI in positive and negative modes identified two unique compounds, while APPI did not reveal any unique compounds.
Complementary ionization techniques and workflows in GC-MS
GC×GC electron ionization MS
The GC-MS participant (Lab 2, Table 1) that reported most compounds (> 500) at an identification confidence of 2 or 3 used GC×GC-EI-MS. One of the main reasons for the high number of reported compounds was likely the high resolving power of GC×GC, which reduces the degree of background interference (i.e., co-elution). This results in cleaner MS spectra and better library match values, which ultimately improves tentative identification. Furthermore, the positions of the chromatographic peaks on the GC×GC plot are correlated to the physicochemical properties of the corresponding chemicals. In this case, the participant used a nonpolar (5% phenyl) column for the first-dimension separation and a semipolar (50% phenyl) column for the second-dimension separation. On such a column set, the first dimension of separation depends on volatility (as previously discussed), while the second dimension of separation depends on polarity. Thus, polar and polarizable compounds are retained more on the second-dimension column than nonpolar compounds. This information can be used as an additional discriminating factor when deciding whether to accept or reject a tentative structure. Collectively, this can allow detection and tentative identification of compounds present at relatively low concentrations, which are often associated with relatively low library match factors.
The ordered structure of GC×GC 2D contour plots also facilitates the identification of structurally related chemicals. The technique is, for example, increasingly used in the petroleum industry to perform PIONA: paraffins (alkanes), iso-paraffins (branched alkanes), olefins (alkenes), naphthenes (cyclic alkanes), and aromatics analysis. A group type separation is obtained in the second dimension, with paraffins eluting first, followed by olefins, naphthenes, monocyclic aromatics, bicyclic aromatics, and tricyclic aromatics [43]. In the first dimension, a separation based on carbon number is obtained. The iso-paraffins elute prior to the corresponding paraffins, in diagonal strikes, often referred to as the roof-tile effect [43].
Through the use of GC×GC, numerous petrogenic and pyrogenic hydrocarbons were tentatively identified and reported, including 50 alkanes, cycloalkanes, and alkenes; 18 monocyclic aromatic hydrocarbons; 43 PAHs; and 24 other polycyclic aromatic compound (PACs). In addition, 125 branched alkanes and alkyl-PAHs were reported. For the branched alkanes, the formula is known, but the degree and position of branching is unknown. Similarly, for the alkyl-PAHs, the formula and number of aromatic rings are known, but the type and position of substituents are unknown. These have therefore been reported as, e.g., C2-anthracene/phenanthrene.
The structured 2D chromatograms make it relatively straightforward to tentatively identify sample constituents belonging to other homologous series of compounds, even if not all of these are represented in commercial EI-MS libraries. Figure 4 shows extracted ion chromatograms (EICs) of diagnostic ions of aliphatic acids, aldehydes, and lactones. Through the detection and characterization of a few members of each class of compounds all members of the respective homologous series can be tentatively identified. In addition to the compounds included in Fig. 3, homologous series of alkylamides, N,N-dimethylamines, n-alkanols, and PEGs were tentatively identified and reported by GC×GC laboratories.
GC×GC atmospheric pressure chemical ionization HRMS
One of the participants (Lab 3, Table 1) used GC×GC-APCI-HR-TOF-MS in both positive and negative ion modes and was able to detect and tentatively identify more than 500 halogenated chemicals. Sixty-five compounds were found using APCI in positive ion mode, including 9 pesticides, 13 organophosphorus and brominated flame retardants, 33 PCBs, and 8 halogenated compounds for which only the formula could be generated. The remaining compounds (468) were all found using APCI in negative ion mode and were all MCCPs. The MCCPs were detected as oxygen adducts, i.e., as [M+O2]−. The homolog pattern is shown in Fig. 5. It is somewhat surprising that no short chain polychlorinated paraffins (SCCPs) were detected as those have previously been reported in house dust [44].
Chlorinated paraffin (CP) mixtures are exceptionally complex and the use of GC×GC greatly facilitates the separation of CP homolog groups as well as isomers, as demonstrated by Korytár et al. [45]. Using this technique, the separation is much improved over 1D GC, and an ordered structure with diagonally arranged peaks is obtained, containing CPs differing in the number of chlorines. There are, however, still overlaps among CPs with the same number of halogens and different numbers of carbons. When combined with a soft ionization technique, such as APCI, a complete characterization of chlorinated paraffin mixtures can be achieved.
GC-APCI-MS has recently attracted attention and has proven valuable in NTS studies [46]. Its main advantage over GC-EI-MS is that molecular ions or molecular ion adducts are usually obtained, which enables the possibility of using an LC-MS/MS type of NTS workflow for the identification of unknowns. In addition, it may provide an attractive option for laboratories that have access to LC-HRMS instrumentation, but no dedicated GC-HRMS instrumentation.
GC-LRMS with complementary full-scan EI and methane PCI and NCI
The main advantage of using a GC coupled with a single quadrupole mass spectrometer (in addition to the relatively low cost and availability) is that there are several easily exchangeable ionization techniques available that provide complementary information and increase the number of compounds that can be tentatively identified with a high level of confidence. One participant used three types of ionization EI, and methane-positive ion chemical ionization (PCI) and positive ion chemical ionization (NCI), all in full-scan mode. The identification workflow was based on the full-scan EI data and the use of mass spectral and LRI databases (allowing a ± 50 RI unit tolerance). Often this was sufficient for a tentative identification; however, many compounds displayed chimeric (mixed) spectra or spectra without a clear molecular ion. In such cases, the PCI and NCI data provided useful complementary information, PCI provided molecular ion or adduct ion information for compounds with high proton affinity, and NCI provided molecular ion information for compounds with high electron affinity and high molecular ion stability. NCI can also be used to verify the presence of electronegative atoms, mainly halogens, through inspection of chlorine and bromine EICs. These compounds can sometimes be tentatively identified by matching with entries in a “home-made” NCI library. Three examples of the complementary use of EI, CI, and LRI information are given in the following sections (i) verification of candidate structure, (ii) correction of proposed structure, and (iii) tentative identification based solely on NCI data.
In the first example, a NIST library search indicated the presence of two isomers of cyhalothrin (MW = 449) in the dust extract. The total ion chromatogram (TIC), full-scan spectrum, and base peak chromatogram (m/z 181) are shown in ESM Fig. S1. The base peak chromatogram displays two peaks, indicated with yellow arrows, potentially corresponding to stereoisomers. However, no molecular ions could be found for verification, even after manual extraction. Instead, the pseudo-molecular mass (m/z 450) of cyhalothrin isomers was confirmed through the use of the PCI result (window B) and NCI confirmed the presence of chlorine. The good agreement of the experimental LRI (2576) and NIST RI (2579) further strengthened the proposed structure.
The second example is illustrated by ESM Fig. S2. The top panel displays an EIC (m/z 163) with three peaks labeled with yellow arrows. Their manually extracted spectra were very similar and one of them is shown (panel B). A NIST search offered N-propyl benzamide as the most likely compound (86% match), but the calculated LRI (2485) did not match that of NIST (1526) indicating a misassignment. After applying some constraints (e.g., size), another candidate was found, dipropyleneglycol dibenzoate (three isomers), which had a much better LRI match (2445). Because the dipropyleneglycol dibenzoate EI spectrum lacks a molecular ion, PCI was used for verification and a pseudo-molecular ion (MH) was found. Dipropyleneglycol dibenzoates had also been detected by other participants, which further strengthens the tentative identification.
The final example is illustrated by Fig. 6. An unknown compound was observed at retention time 15.29 min in the TIC from the NCI analysis of the dust extract. Its full-scan spectrum showed the typical characteristic chlorine isotope distribution pattern of compounds containing three chlorine atoms. After searching a “home-made” NCI library, 1,3,5-trichlorophenol was found to be the closest match. It should have a LRI of 1335 according to NIST and the experimental RI was 1371, which supports the proposed peak assignment, although other trichlorophenol isomers cannot be ruled out. Inspection of the EI and PCI chromatograms did not reveal any signals in the relevant LRI range that could be attributed to trichlorophenols. This is most likely because the response of those is lower in EI and PCI than in NCI, which further corroborates the value of using complementary ionization techniques.
Factors influencing detection potential in suspect and nontarget screening of house dust
Physical–chemical properties of compounds detected by GC- and LC-MS
High complementarity between the techniques used by the participants in the collaborative trial was observed (Fig. 3). GC-MS participants reported mainly small non- and semipolar molecules (ESM Fig. S3, left side), while semipolar and polar compounds dominated the LC-MS results (ESM Fig. S3, right side). The compounds that were reported following both GC-MS and LC-MS analyses have, in general, intermediate size and polarity, as expected.
All LC-MS participants were using positive ion ESI. A few were also using negative ion ESI, APCI, or APPI. However, application of APPI only resulted in the discovery of two unique compounds. This does not mean that a majority of LC-MS-amenable compounds in dust respond well in positive ion ESI. On the contrary, several environmental contaminants respond well in negative ion ESI, APCI, or APPI, but poorly in positive ion ESI [47]. Thus, there is likely a bias in the results toward compounds with high proton affinity, which respond well in positive ion ESI. This may explain the high percentage of compounds with high basicity, such as amines, amides, nitriles, and polyethers (incl. glycols), among the LC-MS datasets.
Among the GC-MS techniques, the use of 2D separations and complementary soft (CI) and traditional (EI) ionization proved valuable. Two participants using GC×GC-APCI-MS and GC×GC-EI-MS, respectively, collectively found more than 1000 compounds. The use of CI did not, in isolation, lead to identification of many compounds, mainly due to lack of commercial CI spectral libraries. However, GC-PCI-MS still proved valuable as it provided molecular ion information that could confirm candidate structures obtained using GC-EI-MS. Similarly, negative ion CI was used to confirm the presence of halogen substituents. This technique has also been used to guide discovery workflows aimed at finding and identifying halogenated environmental contaminants [48]. The PCI and NCI soft ionization techniques are in themselves complementary, as they selectively ionize compounds with high proton affinity and high electron affinity, respectively.
In principle, the techniques used by the participants cover a large part of the chemical domain of contaminants likely to be found in house dust. However, very polar compounds are not sufficiently covered. These require a separate LC-MS analysis employing, e.g., a HILIC column, which was only used by one participant. Consequently, only a few compounds with log Kow values below zero were reported (ESM Fig. S3). Similarly, large nonpolar compounds with molecular weight above 600 Da were also insufficiently covered. The largest hydrocarbon n-alkane detected was n-hexatriacontane (506.6 Da), the largest nonhalogenated compound was tri(2-ethylhexyl) trimellitate (546.4 Da), and the largest of all nonpolar compounds was decabromodiphenyl ether (961.2 Da). However, analysis of the latter was done by targeted methods aimed at brominated flame retardants, utilizing short thin-film GC columns.
Lack of conformity among reported datasets
Almost half of the compounds reported from LC-MS analyses and most of the compounds reported from GC-MS analysis were only reported once.
The lack of agreement in GC-MS results may be attributed to differences in applied methodology and instrumentation. A large share of the results was generated using GC×GC-EI-MS and GC×GC-APCI-MS which differs in selectivity. In addition, many compounds separated by GC×GC would co-elute in 1D-GC, making identification much more difficult. An important share of the unique compounds was also detected using targeted approaches, which usually are more sensitive and selective than nontargeted approaches.
The LC-MS results are more difficult to explain. Almost all compounds were identified using the same technique, LC-ESI(+)-HRMS/MS. A question then arises—Is the small overlap between data generated using similar hardware due to differences in data handling? Most likely, this is part of the reason. However, it is also likely that the experience and time invested by the participants have significantly influenced the outcome.
Almost all LC-MS data originated from target analysis or suspect screening approaches. If we look at the self-reported categorization of workflows, 14% of the reported data was generated using target analysis, 46% using a suspect screening workflow, and 40% using a NTS workflow. However, only one third of the compounds that were self-classified as NTS data had supporting MS/MS information, which is generally required for a tentative identification. Of the remaining 187 compounds, 11 were related to organophosphate and phthalate esters, which had been listed as suspects by the organizers, and 125 were related to glycols that are well-known contaminants in house dust. Besides these, 50 compounds (3% of all reported) were generated using NTS workflows that included MS/MS confirmation.
Consequently, the majority of the confirmed and tentatively identified compounds stem from suspect screening using candidate lists or searches of ESI mass spectral libraries. Different groups have access to different suspect lists and different mass spectral libraries, which often are vendor specific. Obviously, this influenced the compounds identified by the various participants. This may also be one of the major reasons for the poor overlap between the LC-MS and GC-MS datasets. The LC-ESI-MS libraries are usually relatively small and rich in compounds relevant for the life sciences, pharmaceutical research, and environmental and forensic toxicology, while the GC-EI-MS libraries are large, more diverse, and also include a large range of industrial chemicals. Thus, many of the reference mass spectra in the LC-MS libraries are missing in GC-MS libraries, and vice versa.
Guidelines to successful screening and reporting of contaminants in indoor environment samples
Using feasible suspect lists
One of the main outcomes of the collaborative effort is the generation of an extensive database with house dust contaminants. More than 2300 compounds were identified or tentatively identified of which close to 1700 could be assigned exact chemical structures. The database greatly expands our knowledge base of contaminants in house dust. As a comparison, a recent compilation of house dust contaminants by Zhang et al. [49] included a total of 485 compounds, including ca 250 compounds from an earlier compilation by Mercier et al. [50]. In addition, a GC×GC-MS screening of contaminants in house dust revealed 10,000 peaks of which 370 could be characterized (145 PAHs, 52 phthalates, 8 nitro compounds, and 165 chlorine/bromine-containing compounds) [20]. A more recent study using both LC-QTOF-MS and GC-QTOF-MS reported 271 house dust contaminants of which 163 could be unambiguously confirmed by reference standards [21].
The list of dust contaminants generated in the collaborative trial will be amended with additional compounds from the above cited studies and with indoor air contaminants reported by members of the NORMAN Association. This will result in a NORMAN indoor environment contaminants suspect list, which will be shared through the NORMAN suspect list exchange program. NORMAN partners are also working on compiling and curating a master list termed “SusDat” containing information needed in NTS workflows for screening of known environmentally relevant compounds (both lists can be found at www.norman-network.net, “databases” tab). Next to unique identifiers such as StdInChIKey, MS Ready InChIKey, SMILE, and QSAR model-predicted ecotoxicological limit values, exact masses of expected adduct ions in both positive and negative ionization modes and related RTIs are now available for more than 40,000 substances (as of October 2018). Work is currently in progress on obtaining experimental and predicted mass fragments for all compounds to support identifications of these suspects in the NORMAN Digital Sample Freezing Platform (DSFP; www.norman-data.eu).
The “CompTox Chemistry Dashboard” at the U.S. Environmental Protection Agency (U.S. EPA) is an even larger well-curated repository of compound information. It contains many potential candidate lists, including the NORMAN lists, but also contains useful additional data to support identification, such as physicochemical properties, literature references, patent data, functional uses, and (eco)toxicological data. NORMAN and U.S. EPA closely cooperate on further development of SusDat and the two databases are interlinked.
The above and other similar initiatives are in progress to expand the support of suspect screening and NTS workflows, including MS spectra predictions, and prioritization of compounds found in such studies. A recent paper by Rager et al. [22] illustrates the potential of such platforms for combined LC-MS suspect screening analysis, exposure and toxicity prediction, and ranking of dust contaminants. An even more recent paper by Phillips et al. [51] describes the use of GC×GC-MS for suspect screening analysis of chemicals in consumer products, which are highly relevant as sources for contaminants in house dust.
Using complementary chromatographic and ionization techniques
Access to dedicated suspect lists through NORMAN, U.S. EPA, and other web resources will make it possible to better utilize the information generated by less commonly used ionization techniques, such as CI, APCI, and APPI, and thereby increase the coverage of contaminants in indoor environment samples. It will also increase the overlap of the chemical domains covered by LC-MS and GC-MS techniques. Detection and tentative identification of compounds by two or more independent analytical method greatly enhances the identification confidence.
The parallel use of EI and PCI may yield library searchable spectra and molecular ion information, which, when combined with RI information, can result in a level 2 identification confidence. The use of NCI and negative ion APCI and ESI can be used to selectively screen for halogenated compounds [52], which often cause environmental concern. Furthermore, APCI is generally less sensitive to matrix effects than ESI and, therefore, useful for semiquantification of LC-MS-amenable compounds.
Based on the results of the collaborative trial, the most powerful combination of instrumental techniques seems to be ESI-HRMS/MS and GC×GC-EI-(HR)MS. Most of the reported compounds stem from either of those techniques. However, with the easy access to tailored suspect lists, it may prove fruitful in the future to complement those techniques with one or more CI techniques. Many top-end LC-HRMS systems allow both LC-APCI and GC-APCI analysis to be performed on the same platform, which may be worth exploring further.
Although not tested in the collaborative trial, liquid chromatography–based multidimensional techniques (e.g., 2D liquid chromatography (LC×LC) MS and LC ion mobility MS/MS) and supercritical fluid chromatography (SFC) are also expected to provide enhanced separation power and peak capacity. Current developments in multidimensional data evaluation software may unravel the full potential of such techniques.
Using retention indices to enhance confidence in identification
Suspect screening using suspect lists and molecular formula generated using LC-HRMS information will, initially, have a high rate of false positives. The number of false positives can be subsequently reduced using various discriminators. One of the most effective discriminators is chromatographic retention indices. An automated routine was developed by partners of the NORMAN network to predict LC RTIs using a set of calibration compounds [29] or use it experimentally for normalization and prioritization of candidate molecules by correlated logD values [24, 30], and this was subsequently used in the present work for LC-MS data curation. The approach utilizes a set of carefully chosen molecular descriptors and quantitative structure–retention relationships to predict the RTIs of candidate structures based on the retention times of the calibrants while at the same time determining if the individual candidates are within the model domain. Work is currently in progress to generate RTIs for all compounds on the SusDat list which, once fully implemented, will greatly facilitate the suspect qualification process.
Although the NIST library of EI-MS spectra includes GC RI information, it is not always easy to use. Some participants in the collaborative trial did not appear to use this information, which resulted in misassignments. Some MS software allows the use of RI information for ranking of the NIST spectral search hit list, which reduces the probability of false positives. However, even if the NIST database contains more than 72,000 compounds, RIs are still lacking for many compounds encountered in a complex matrix, such as house dust. A simple QSRR, such as the Abraham general solubility model developed for curation of the collaborative trial, may then be used for prediction of LRIs. In many cases, a sufficiently good prediction can be achieved by a single-parameter retention model, using linear regression of the GC retention times vs. the analyte vapor–hexadecane partition coefficients (Abraham L coefficient). A linear regression model created using the curated GC-MS data had an r2 = 0.95.
For GC×GC data, two independent retention times (or indices) are available that can be used to discriminate between potential candidates and to reduce the percentage of false positives. Methods for GC×GC retention indexing and prediction have recently been developed and tested [53, 54].
Using in silico–predicted mass spectra and metadata to enhance the identification confidence
Several participants used in silico tools (MetFrag, MSC (Molecular Structure Correlator), and Mass Frontier) for fragment confirmation, thereby raising the identification confidence. In this context, the development of automatic routines for suspect list and database curation and generation of “MS-ready” structures is of importance [55]. These tools have been adopted in the CompTox database and the substances have been desalted, desolvated, and had stereochemistry removed to represent the forms of chemicals observed via HRMS. Easy access to curated MS-ready structures will greatly facilitate suspect screening of known unknowns. In the future, the NORMAN SusDat and the Dashboard records may be linked to those from open spectral libraries (e.g., MassBank and MoNa) and fragmentation prediction resources (e.g., MetFrag, CFM-ID, and Mass Frontier) to further streamline the process to raise the identification confidence [56].
In addition, further ranking of candidate chemicals using data source ranking or functional use filtering has proven effective. The latest CASMI (Critical Assessment of Small Molecule Identification) challenge showed that the success rate of high-throughput (semiautomated) identification routines could be increased from 34 to 70% by including metadata (www.casmi-contest.org/2016/). Data source ranking (number of PubChem references or patents) is supported in MetFrag [25] and data source statistics (total number of data sources and of PubChem records/data sources), and product occurrence data (EPA CPCat) is available through CompTox Dashboard [57]. Chemical use and function category data, organized with descriptors such as detergent, food-additive, etc., are also available in the dashboard. These data may support tentative chemical identification through filtering by the use category relative to the sample medium—here dust. Further development to create a weighting-based or tiered ranking approach for identification using the aforementioned criteria as inputs is underway [57].
Using open-source data processing platforms
The poor overlap between the GC-MS and LC-MS-derived datasets from individual participants is hypothesized to be mainly influenced by the varying experiences of the laboratories, the time spent for analyzing the data, and varying access to tools such as mass spectral libraries, dust-relevant suspect lists, and data-processing tools, rather than instrumental limitations. This hypothesis was confirmed after uploading selected LC-MS data to the recently developed Norman DSFP and perform suspect screening using the complete list of compounds identified in the study. Briefly, the dust LC-MS raw data files (from different vendors) were converted to mzML format, imported to DSFP together with instrumental metadata, contributor details, and retention times of the retention index calibrants. An internally standardized procedure of peak-picking and componentization (using previously optimized parameters) is utilized to create a component list, which then can be matched against any list of suspected substances considering their exact mass, fragmentation, and retention time plausibility through QSRR RTI models. The tentative results were obtained in a short time and the number of identified compounds exceeded on average 500. Additional compound lists can be found at the NORMAN Suspect List Exchange (https://www.norman-network.com/?q=node/236). Suspect screening against all the compounds in the NORMAN SusDat database allowed for provisional identification of additional 476 compounds not reported by the participants.
The FOR-IDENT platform offers another open access tool (https://water.for-ident.org), as previously discussed. It uses retention time/RTI, accurate mass/empirical formula, and mass spectra information of uploaded (suspects or nontarget screening) mzML files or raw data files from LC-MS vendors, which are compared with the information of compounds in the STOFF-IDENT database (formula, logD, and in silico fragmentation spectra from the MetFrag tool and MassBank entries). The FOR-IDENT platform gives on this basis molecular identification suggestions with prioritization levels.
Using harmonized terms and identification levels when reporting untargeted analysis data
From the results of the collaborative trial, it is clear that not even established users of untargeted analytical techniques have a common use of the terms “target,” “suspect,” and “nontarget” analysis and the identification confidence levels 2–5 [16, 26]. It seemed to be a more coherent view on the terms and levels among the LC-HRMS community, which is logical. That community was instrumental in the development of a common nomenclature and identification confidence system. In future reporting of untargeted analysis data, LC-HRMS users are encouraged to strictly follow the guidelines laid out by Schymanski et al. [16].
The identification confidence scheme [16, 26] appeared less easily applicable for the GC-MS participants, most likely due to differences in preferred workflows. Level 5 (molecular weight known) and level 4 (formula known) make little sense to most GC-MS users. They work directly with library search results and must decide when to accept the top hit from library, when to pick another candidate, and when to reject all candidates (and potentially peruse a true nontargeted workflow). Guidance is needed on what is required to qualify a provisional structure for level 3 (plausible structure) and level 2 (probable structure), respectively. Work is currently underway to formulate such guidelines.
Electronic supplementary material
Acknowledgments
The NORMAN network is thanked for acting as the supporting organization of the study and the research group of Prof. Miriam Diamond, University of Toronto, Canada University of Toronto for the donation of the dust sample.
Biographies
Pawel Rostkowski
holds a Ph.D. in chemistry from the University of Gdansk, Poland. Since 2012, he has been working as a senior scientist at NILU—Norwegian Institute for Air Research in Kjeller, Norway. His current research is focused on the development of sample preparation methods and identification of new emerging contaminants in different matrices with application of high-resolution mass spectrometric techniques and suspect and nontarget screening approaches.
Peter Haglund
holds a Ph.D. degree in analytical chemistry from Stockholm University. He is currently a professor of environmental analytical chemistry at Umeå University, Sweden, and is leading a research team focused on development of hyphenated chromatographic and mass spectrometric techniques and their use for nontarget screening and identification of new environmental contaminants.
Reza Aalizadeh
is a Ph.D. student in analytical chemistry at the National and Kapodistrian University of Athens, Greece. He is working on the development and application of chemometric techniques and workflows to facilitate the identification of unknowns by nontarget screening in samples analyzed by high-resolution mass spectrometry.
Nikiforos Alygizakis
is a Marie Skłodowska-Curie fellow, working at the Environmental Institute in Kos, Slovakia. His main research interests are digital archiving of liquid and gas chromatography high-resolution mass spectrometry data, wide-scope retrospective screening, and prioritization of substances in nontarget screening datasets.
Nikolaos S. Thomaidis
is Professor of Analytical Chemistry in the Department of Chemistry of the National and Kapodistrian University of Athens. His current research field, among others, includes the development of new LC- and GC-HRMS methods for the identification of new polar and nonpolar compounds in the environment and in food samples; the development of target, suspect, and nontarget screening workflows and their application to food authenticity studies; and environmental research with focus on emerging contaminants and their transformation products.
Joaquin Beltran
is Assistant Professor in the Physical and Analytical Chemistry Department and member of the Research Institute of Pesticides and Water of the University Jaume I. His research is focused on the use of chromatography/mass spectrometry techniques (GC-MS) in last-generation high-resolution MS instruments, with special focus on metabolomic approaches for the determination of organic compounds in environmental, food, and biological fields.
Pernilla Bohlin-Nizzetto
holds a Ph.D. in occupational medicine from the University of Gothenburg, Sweden. She currently works as a senior scientist at NILU. Her main research interests are regulated and emerging organic contaminants in indoor and ambient environments and sampling methodologies of thereof.
Petra Booij
holds a Ph.D. in environmental chemistry from the VU University in Amsterdam (NL). She has worked at RECETOX, Masaryk University in Brno (CZ) on nontarget screening and identification of environmental contaminants using mass spectrometry. She is currently working at GlaxoSmithKline in Stevenage (UK) on investigations into extractables and leachables in support of new drug applications.
Hélène Budzinski
holds a Ph.D. in analytical chemistry. She is a CNRS research director working at the University of Bordeaux, developing environmental chemistry research. She studies the occurrence, fate, and toxic impacts of organic pollutants and develops analytical tools for the determination of contaminants at ultra-trace levels with an emphasis on mass spectrometry and passive samplers.
Pamela Brunswick
, Ph.D., currently works as a chemist for Environment and Climate Change Canada in North Vancouver, BC, Canada. Pamela graduated university in the UK and has a background in industry and academia, but currently focuses on the application of high-resolution mass spectrometry in support of environmental law enforcement, with the gratifying pleasure of environmental protection.
Adrian Covaci
is a professor of environmental chemistry and toxicology at the University of Antwerp (Belgium). His research interests include analytical method development and validation including non-target screening approaches, human exposome, elucidation of human metabolism of new chemicals using in vitro hepatic models, investigation of human exposure pathways and metabolomics for in vitro and in vivo systems using high-resolution mass spectrometry.
Christine Gallampois
holds a Ph.D. degree in environmental analytical chemistry from RWTH Aachen University/Helmholtz Centre for Environmental Research—UFZ and is currently working at Umeå University. Her expertise includes environmental and analytical chemistry, liquid chromatography, high-resolution mass spectrometry, ion mobility mass spectrometry, nontarget identification, effect-directed analysis, and mutagenicity.
Sylvia Grosse
was a researcher at the TUM and is an expert on nontarget screening, i.e., chromatographic separations, mass spectrometric detection, and data evaluation workflows. Currently, she is developing new analytical strategies at Thermo Fisher Scientific, Germering, Germany.
Ralph Hindle
has a B.Sc. in chemistry from the University of Ottawa. He is the owner/operator of Vogon Laboratory Services in Cochrane, Alberta, Canada. He provides analytical services, method development, training, and consulting for small organic molecules using LC/QTOF, LC/QQQ, and GC/QQQ.
Ildiko Ipolyi
holds a Ph.D. in analytical chemistry from the Szent István University of Budapest, Hungary. She is a senior project manager at the Environmental Institute in Kos, Slovakia. Her research interests are focused mainly on environmental monitoring data management for the NORMAN Association, data quality and assurance issues, and organization of international interlaboratory comparisons.
Karl J. Jobst
obtained his Ph.D. in analytical chemistry from McMaster University in 2011. He is currently a scientist with the Ontario Ministry of the Environment and holds adjunct status at his alma mater and the University of Toronto Scarborough. His research interests focus on the development and application of mass spectrometric and computational techniques for the analysis of complex environmental samples.
Sarit Kaserzon
is a research fellow at the Queensland Alliance for Environmental Health Sciences (QAEHS), The University of Queensland. Her research interests have focused on developing novel sampling and analytical methods and approaches to detect trends, levels, and fate of persistent and emerging organic environmental pollutants including developing novel methods for the rapid screening and identification of chemical hazards in drinking water.
Pim Leonards
is Professor in environmental bioanalytical chemistry. He has more than 20 years of experience in the field and experimental studies related to environmental chemistry, analytical method development, bioaccumulation, indoor exposure assessment, and metabolomics. Nowadays, his focus is on emerging chemicals, indoor exposure assessment, and metabolomics.
Francois Lestremau
is a senior scientist at the National Competence Centre for Industrial Safety and Environmental Protection (INERIS). His research activity focuses on the development of analytical methods for the measurement of environmental pollutants in biological, water, air, or soil matrices.
Thomas Letzel
is an analytical chemist with almost 20 years of professional experience in the field of analytical (nontarget) screening techniques using LC, SFC, and GC with mass spectrometric detection. He was Head of the Analytical Research Group ‘AFG’ at the TUM. This year, he will continue research and consulting in nontarget screening in the independent AFIN-TS GmbH.
Jörgen Magnér
holds a Ph.D. in environmental analytical chemistry from the University of Stockholm, Sweden. He is currently employed by the Swedish Chemicals Agency where he evaluates the environmental fate of chemicals before they are put on the market. His field of expertise is to predict the fate and distribution of anthropogenic chemicals in the environment.
Hidenori Matsukami
holds a Ph.D. in environmental science from the University of Tokyo and is working at the Center for Material Cycles and Waste Management Research of the National Institute for Environmental Studies, Japan. His current research activity is in the field of the environmentally sound management of wastes; particularly, his interest focuses on environmental contamination and human exposure to harmful organic chemicals released from wastes during recycling.
Christoph Moschet
holds a Ph.D. degree in environmental chemistry from the Swiss Federal Institute of Technology in Zürich, Switzerland. He has been working as a postdoctoral researcher at the Department of Environmental Engineering at UC Davis, California. His main research interest is the use of high-resolution mass spectrometry in order to find unknown contaminants in environmental media.
Peter Oswald
holds a Ph.D. in analytical chemistry from the Slovak Technical University in Bratislava, Slovakia. He is a senior researcher and Head of the Analytical Laboratory at the Environmental Institute in Kos, Slovakia. His main research interest is in analytical method development including automated methods of sample preparation in combination with gas and liquid chromatography coupled to (high-resolution) mass spectrometry.
Merle M. Plassmann
holds a Ph.D. in environmental sciences and is currently working at the Institute of Environmental Science and Analytical Chemistry, Stockholm University, Sweden. Her research field includes both targeted analysis of per- and polyfluorinated substances and nontarget screening of diverse environmental matrices, focusing on the application of LC-HRMS and combustion-IC.
Jaroslav Slobodnik
is Director of the Environmental Institute in Kos, Slovakia. His expertise includes environmental analytical chemistry and environmental risk assessment in the context of science-to-policy developments in Europe. He is a Chairman of the NORMAN Association dealing with emerging substances.
Chun Yang
is Head of the Chemical Research Laboratory, Emergencies Science and Technology Section, Environment and Climate Change Canada, Ottawa, Canada. His current specialties and research interests include forensic fingerprinting analysis of oils and other potential spill candidates, properties and environmental behaviors of organic pollutants, and application of high-resolution mass spectrometry in target and nontarget analysis of emerging environmental contaminants.
Compliance with ethical standards
No violation of human or animal rights occurred during this investigation. The dust samples were collected after informed consent by the occupants of the premises sampled.
Consent to submit has been received from all co-authors.
Conflict of interest
The authors declare that they have no conflict of interest.
Footnotes
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Butte W, Heinzow B. Pollutants in house dust as indicators of indoor contamination. Rev Environ Contam Toxicol. 2002;175:1–46. [PubMed] [Google Scholar]
- 2.Laborie S, Moreau-Guigon E, Alliot F, Desportes A, Oziol L, Chevreuil M. A new analytical protocol for the determination of 62 endocrine-disrupting compounds in indoor air. Talanta. 2016;147:132–141. doi: 10.1016/j.talanta.2015.09.028. [DOI] [PubMed] [Google Scholar]
- 3.Loganathan SN, Kannan K. Occurrence of bisphenol A in indoor dust from two locations in the eastern United States and implications for human exposures. Arch Environ Contam Toxicol. 2011;61(1):68–73. doi: 10.1007/s00244-010-9634-y. [DOI] [PubMed] [Google Scholar]
- 4.Liao C, Liu F, Guo Y, Moon HB, Nakata H, Wu Q, Kannan K. Occurrence of eight bisphenol analogues in indoor dust from the United States and several Asian countries: implications for human exposure. Environ Sci Technol. 2012;46:9138–9145. doi: 10.1021/es302004w. [DOI] [PubMed] [Google Scholar]
- 5.Wang L, Liao C, Liu F, Wu Q, Guo Y, Moon HB, Nakata H, Kannan K. Occurrence and human exposure of p-hydroxybenzoic acid esters (parabens), bisphenol A diglycidyl ether (BADGE), and their hydrolysis products in indoor dust from the United States and three East Asian countries. Environ Sci Technol. 2012;46:11584–11593. doi: 10.1021/es303516u. [DOI] [PubMed] [Google Scholar]
- 6.Tran TM, Minh TB, Kumosani TA, Kannan K. Occurrence of phthalate diesters (phthalates), p-hydroxybenzoic acid esters (parabens), bisphenol A diglycidyl ether (BADGE) and their derivatives in indoor dust from Vietnam: implications for exposure. Chemosphere. 2016;144:1553–1559. doi: 10.1016/j.chemosphere.2015.10.028. [DOI] [PubMed] [Google Scholar]
- 7.Larsson K, Lindh CH, Jonsson BA, Giovanoulis G, Bibi M, Bottai M, Bergstrom A, Berglund M. Phthalates, non-phthalate plasticizers and bisphenols in Swedish preschool dust in relation to children’s exposure. Environ Int. 2017;102:114–124. doi: 10.1016/j.envint.2017.02.006. [DOI] [PubMed] [Google Scholar]
- 8.Bornehag CG, Sundell J, Weschler CJ, Sigsgaard T, Lundgren B, Hasselgren M, Hagerhed-Engman L. The association between asthma and allergic symptoms in children and phthalates in house dust: a nested case-control study. Environ Health Perspect. 2004;112:1393–1397. doi: 10.1289/ehp.7187. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Samet JM, Marbury MC, Spengler JD. Health effects and sources of indoor air pollution. Part I. Am Rev Respir Dis. 1987;136:1486–1508. doi: 10.1164/ajrccm/136.6.1486. [DOI] [PubMed] [Google Scholar]
- 10.Samet JM, Marbury MC, Spengler JD. Health effects and sources of indoor air pollution. Part II. Am Rev Respir Dis. 1988;137:221–242. doi: 10.1164/ajrccm/137.1.221. [DOI] [PubMed] [Google Scholar]
- 11.Wormuth M, Scheringer M, Vollenweider M, Hungerbuhler K. What are the sources of exposure to eight frequently used phthalic acid esters in Europeans? Risk Anal. 2006;26:803–824. doi: 10.1111/j.1539-6924.2006.00770.x. [DOI] [PubMed] [Google Scholar]
- 12.Wu N, Herrmann T, Paepke O, Tickner J, Hale R, Harvey LE, La GM, Mcclean MD, Webster TF. Human exposure to PBDEs: associations of PBDE body burdens with food consumption and house dust concentrations. Environ Sci Technol. 2007;41:1584–1589. doi: 10.1021/es0620282. [DOI] [PubMed] [Google Scholar]
- 13.Rudel RA, Perovich LJ. Endocrine disrupting chemicals in indoor and outdoor air. Atmos Environ. 2009;43:170–181. doi: 10.1016/j.atmosenv.2008.09.025. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Veenaas C, Haglund P. Methodology for non-target screening of sewage sludge using comprehensive two-dimensional gas chromatography coupled to high-resolution mass spectrometry. Anal Bioanal Chem. 2017;409:4867–4883. doi: 10.1007/s00216-017-0429-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Blum KM, Andersson PL, Renman G, Ahrens L, Gros M, Wiberg K, Haglund P. Non-target screening and prioritization of potentially persistent, bioaccumulating and toxic domestic wastewater contaminants and their removal in on-site and large-scale sewage treatment plants. Sci Total Environ. 2017;575:265–275. doi: 10.1016/j.scitotenv.2016.09.135. [DOI] [PubMed] [Google Scholar]
- 16.Schymanski EL, Singer HP, Slobodnik J, Ipolyi IM, Oswald P, Krauss M, Schulze T, Haglund P, Letzel T, Grosse S, Thomaidis NS, Bletsou A, Zwiener C, Ibanez M, Portoles T, de Boer R, Reid MJ, Onghena M, Kunkel U, Schulz W, Guillon A, Noyon N, Leroy G, Bados P, Bogialli S, Stipanicev D, Rostkowski P, Hollender J. Non-target screening with high-resolution mass spectrometry: critical review using a collaborative trial on water analysis. Anal Bioanal Chem. 2015;407:6237–6255. doi: 10.1007/s00216-015-8681-7. [DOI] [PubMed] [Google Scholar]
- 17.Gago-Ferrero P, Schymanski EL, Bletsou AA, Aalizadeh R, Hollender J, Thomaidis NS. Extended suspect and non-target strategies to characterize emerging polar organic contaminants in raw wastewater with LC-HRMS/MS. Environ Sci Technol. 2015;49:12333–12341. doi: 10.1021/acs.est.5b03454. [DOI] [PubMed] [Google Scholar]
- 18.Bletsou AA, Ferrero PG, Psoma AK, Aalizadeh R, Thomaidis NS. Development of a LC-HRMS workflow for suspect and non-target screening of contaminants of emerging concern in environmental water samples. Proceedings of Am Chem Soc fall meeting 2014; https://www.acs.org/content/acs/en/meetings/national-meeting/about/meetings-archive.html. Accessed 18 Feb 2019.
- 19.Ouyang XY, Weiss JM, de Boer J, Lamoree MH, Leonards PEG. Non-target analysis of household dust and laundry dryer lint using comprehensive two-dimensional liquid chromatography coupled with time-of-flight mass spectrometry. Chemosphere. 2017;166:431–437. doi: 10.1016/j.chemosphere.2016.09.107. [DOI] [PubMed] [Google Scholar]
- 20.Hilton DC, Jones RS, Sjodin A. A method for rapid, non-targeted screening for environmental contaminants in household dust. J Chromatogr A. 2010;1217:6851–6856. doi: 10.1016/j.chroma.2010.08.039. [DOI] [PubMed] [Google Scholar]
- 21.Moschet C, Anumol T, Lew BM, Bennett DH, Young TM. Household dust as a repository of chemical accumulation: new insights from a comprehensive high-resolution mass spectrometric study. Environ Sci Technol. 2018;52:2878–2887. doi: 10.1021/acs.est.7b05767. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Rager JE, Strynar MJ, Liang S, McMahen RL, Richard AM, Grulke CM, Wambaugh JF, Isaacs KK, Judson R, Williams AJ, Sobus JR. Linking high resolution mass spectrometry data with exposure and toxicity forecasts to advance high-throughput environmental monitoring. Environ Int. 2016;88:269–280. doi: 10.1016/j.envint.2015.12.008. [DOI] [PubMed] [Google Scholar]
- 23.Smith CA, Want EJ, O'Maille G, Abagyan R, Siuzdak G. XCMS: processing mass spectrometry data for metabolite profiling using nonlinear peak alignment, matching, and identification. Anal Chem. 2006;78:779–787. doi: 10.1021/ac051437y. [DOI] [PubMed] [Google Scholar]
- 24.Grosse S, Letzel T. User manual for STOFF-IDENT database. 2016. https://www.lfu.bayern.de/stoffident/stoffident-static-content/html/download/manual.pdf. Accessed 18 Feb 2019.
- 25.Ruttkies C, Schymanski EL, Wolf S, Hollender J, Neumann S. MetFrag relaunched: incorporating strategies beyond in silico fragmentation. J Cheminform. 2016;8(3). 10.1186/s13321-016-0115-9. [DOI] [PMC free article] [PubMed]
- 26.Schymanski EL, Jeon J, Gulde R, Fenner K, Ruff M, Singer HP, Hollender J. Identifying small molecules via high resolution mass spectrometry: communicating confidence. Environ Sci Technol. 2014;48:2097–2098. doi: 10.1021/es5002105. [DOI] [PubMed] [Google Scholar]
- 27.Wolf S, Schmidt S, Muller-Hannemann M, Neumann S. In silico fragmentation for computer assisted identification of metabolite mass spectra. BMC Bioinformatics. 2010;11:148. doi: 10.1186/1471-2105-11-148. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Allen F, Pon A, Wilson M, Greiner R, Wishart D. CFM-ID: a web server for annotation, spectrum prediction and metabolite identification from tandem mass spectra. Nucleic Acids Res. 2014;42(web server issue):W94–W99. doi: 10.1093/nar/gku436. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Aalizadeh R, Thomaidis NS, Bletsou AA, Gago-Ferrero P. Quantitative structure-retention relationship models to support nontarget high-resolution mass spectrometric screening of emerging contaminants in environmental samples. J Chem Inf Model. 2016;56:1384–1398. doi: 10.1021/acs.jcim.5b00752. [DOI] [PubMed] [Google Scholar]
- 30.Grosse S, Letzel T. User manual for FOR-IDENT database. 2017. https://water.for-ident.org/download/manual.pdf. Accessed 18 Feb 2019.
- 31.van Den Dool H, Kratz P. A generalization of the retention index system including linear temperature programmed gas-liquid partition chromatography. J Chromatogr A. 1963;11:463–471. doi: 10.1016/S0021-9673(01)80947-X. [DOI] [PubMed] [Google Scholar]
- 32.Persson J, Wang T, Hagberg J. Organophosphate flame retardants and plasticizers in indoor dust, air and window wipes in newly built low-energy preschools. Sci Total Environ. 2018;628-629:159–168. doi: 10.1016/j.scitotenv.2018.02.053. [DOI] [PubMed] [Google Scholar]
- 33.Larsson K, de Wit CA, Sellstrom U, Sahlstrom L, Lindh CH, Berglund M. Brominated flame retardants and organophosphate esters in preschool dust and children’s hand wipes. Environ Sci Technol. 2018;52:4878–4888. doi: 10.1021/acs.est.8b00184. [DOI] [PubMed] [Google Scholar]
- 34.Zhou L, Hiltscher M, Puttmann W. Occurrence and human exposure assessment of organophosphate flame retardants in indoor dust from various microenvironments of the Rhine/Main region, Germany. Indoor Air. 2017;27:1113–1127. doi: 10.1111/ina.12397. [DOI] [PubMed] [Google Scholar]
- 35.He R, Li Y, Xiang P, Li C, Zhou C, Zhang S, Cui X, Ma LQ. Organophosphorus flame retardants and phthalate esters in indoor dust from different microenvironments: bioaccessibility and risk assessment. Chemosphere. 2016;150:528–535. doi: 10.1016/j.chemosphere.2015.10.087. [DOI] [PubMed] [Google Scholar]
- 36.de Boer J, Ballesteros-Gomez A, Leslie HA, Brandsma SH, Leonards PE. Flame retardants: dust - and not food - might be the risk. Chemosphere. 2016;150:461–464. doi: 10.1016/j.chemosphere.2015.12.124. [DOI] [PubMed] [Google Scholar]
- 37.Coelho SD, Sousa AC, Isobe T, Kim JW, Kunisue T, Nogueira AJ, Tanabe S. Brominated, chlorinated and phosphate organic contaminants in house dust from Portugal. Sci Total Environ. 2016;569-570:442–449. doi: 10.1016/j.scitotenv.2016.06.137. [DOI] [PubMed] [Google Scholar]
- 38.van der Veen I, de Boer J. Phosphorus flame retardants: properties, production, environmental occurrence, toxicity and analysis. Chemosphere. 2012;88:1119–1153. doi: 10.1016/j.chemosphere.2012.03.067. [DOI] [PubMed] [Google Scholar]
- 39.Salis S, Testa C, Roncada P, Armorini S, Rubattu N, Ferrari A, Miniero R, Brambilla G. Occurrence of imidacloprid, carbendazim, and other biocides in Italian house dust: potential relevance for intakes in children and pets. J Environ Sci Health B. 2017;52:699–709. doi: 10.1080/03601234.2017.1331675. [DOI] [PubMed] [Google Scholar]
- 40.Balducci C, Perilli M, Romagnoli P, Cecinato A. New developments on emerging organic pollutants in the atmosphere. Environ Sci Pollut Res Int. 2012;19:1875–1884. doi: 10.1007/s11356-012-0815-2. [DOI] [PubMed] [Google Scholar]
- 41.Merel S, Snyder SA. Critical assessment of the ubiquitous occurrence and fate of the insect repellent N,N-diethyl-m-toluamide in water. Environ Int. 2016;96:98–117. doi: 10.1016/j.envint.2016.09.004. [DOI] [PubMed] [Google Scholar]
- 42.Bernhard M, Eubeler JP, Zok S, Knepper TP. Aerobic biodegradation of polyethylene glycols of different molecular weights in wastewater and seawater. Water Res. 2008;42:4791–4801. doi: 10.1016/j.watres.2008.08.028. [DOI] [PubMed] [Google Scholar]
- 43.Beens J, Blomberg J, Schoenmakers PJ. Proper tuning of comprehensive two-dimensional gas chromatography (GC×GC) to optimize the separation of complex oil fractions. J High Resolut Chromatogr. 2000;23:182–188. doi: 10.1002/(SICI)1521-4168(20000301)23:3<182::AID-JHRC182>3.0.CO;2-E. [DOI] [Google Scholar]
- 44.Friden UE, McLachlan MS, Berger U. Chlorinated paraffins in indoor air and dust: concentrations, congener patterns, and human exposure. Environ Int. 2011;37:1169–1174. doi: 10.1016/j.envint.2011.04.002. [DOI] [PubMed] [Google Scholar]
- 45.Korytár P, Parera J, Leonards PEG, Santos FJ, de Boer J, Brinkman UAT. Characterization of polychlorinated n-alkanes using comprehensive two-dimensional gas chromatography–electron-capture negative ionisation time-of-flight mass spectrometry. J Chromatogr A. 2005;1086:71–82. doi: 10.1016/j.chroma.2005.05.003. [DOI] [PubMed] [Google Scholar]
- 46.Portolés T, Mol JGJ, Sancho JV, Hernández F. Use of electron ionization and atmospheric pressure chemical ionization in gas chromatography coupled to time-of-flight mass spectrometry for screening and identification of organic pollutants in waters. J Chromatogr A. 2014;1339:145–153. doi: 10.1016/j.chroma.2014.03.001. [DOI] [PubMed] [Google Scholar]
- 47.Thurman EM, Ferrer I, Barcelo D. Choosing between atmospheric pressure chemical ionization and electrospray ionization interfaces for the HPLC/MS analysis of pesticides. Anal Chem. 2001;73:5441–5449. doi: 10.1021/ac010506f. [DOI] [PubMed] [Google Scholar]
- 48.Carolin H, Walter V. A non-targeted gas chromatography/electron capture negative ionization mass spectrometry selected ion monitoring screening method for polyhalogenated compounds in environmental samples. Rapid Commun Mass Spectrom. 2015;29:619–628. doi: 10.1002/rcm.7143. [DOI] [PubMed] [Google Scholar]
- 49.Zhang J, Kamstra JH, Ghorbanzadeh M, Weiss JM, Hamers T, Andersson PL. In silico approach to identify potential thyroid hormone disruptors among currently known dust contaminants and their metabolites. Environ Sci Technol. 2015;49:10099–10107. doi: 10.1021/acs.est.5b01742. [DOI] [PubMed] [Google Scholar]
- 50.Mercier F, Glorennec P, Thomas O, Bot BL. Organic contamination of settled house dust, a review for exposure assessment purposes. Environ Sci Technol. 2011;45:6716–6727. doi: 10.1021/es200925h. [DOI] [PubMed] [Google Scholar]
- 51.Phillips KA, Yau A, Favela KA, Isaacs KK, McEachran A, Grulke C, Richard AM, Williams AJ, Sobus JR, Thomas RS, Wambaugh JF. Suspect screening analysis of chemicals in consumer products. Environ Sci Technol. 2018;52:3125–3135. doi: 10.1021/acs.est.7b04781. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Buser H-R. Brominated and brominated/chlorinated dibenzodioxins and dibenzofurans: potential environmental contaminants. Chemosphere. 1987;16:713–732. doi: 10.1016/0045-6535(87)90007-5. [DOI] [Google Scholar]
- 53.Veenaas C, Haglund P. A retention index system for comprehensive two-dimensional gas chromatography using polyethylene glycols. J Chromatogr A. 2018;1536:67–74. doi: 10.1016/j.chroma.2017.08.062. [DOI] [PubMed] [Google Scholar]
- 54.Veenaas C, Linusson A, Haglund P. Retention-time prediction in comprehensive two-dimensional gas chromatography to aid identification of unknown contaminants. Anal Bioanal Chem, on-line 20 October 2018. 10.1007/s00216-018-1415-x. [DOI] [PMC free article] [PubMed]
- 55.Schymanski EL, Williams AJ. Open science for identifying “known unknown” chemicals. Environ Sci Technol. 2017;51:5357–5359. doi: 10.1021/acs.est.7b01908. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56.Sobus JR, Wambaugh JF, Isaacs KK, Williams AJ, McEachran AD, Richard AM, Grulke CM, Ulrich EM, Rager JE, Strynar MJ, Newton SR. Integrating tools for non-targeted analysis research and chemical safety evaluations at the US EPA. J Expo Sci Environ Epidemiol. 2018;28:411–426. doi: 10.1038/s41370-017-0012-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 57.McEachran AD, Sobus JR, Williams AJ. Identifying known unknowns using the US EPA’s CompTox Chemistry Dashboard. Anal Bioanal Chem. 2017;409:1729–1735. doi: 10.1007/s00216-016-0139-z. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.