Dispersive Solid Phase Extraction Using Magnetic Nanoparticles Performed in a Narrow-Bored Tube for Extraction of Atorvastatin, Losartan, and Valsartan in Plasma

Mir Ali Farajzadeh 1,2,*, Adeleh Yadeghari 1, Maryam Abbaspour 1
PMCID: PMC6468226  PMID: 31011568

Abstract

Purpose: In this investigation, a new version of magnetic solid phase extraction (MSPE) performed in a narrow–bore tube has been proposed. In this study, hydrophobic octyl (C8) functionalized Fe3O4 magnetic nanoparticles (MNPs) stabilized by SiOH groups (Fe3O4@SiO2@C8) are used as magnetic nano–sorbents for the extraction of cardiovascular drugs from human plasma prior to their determination by high performance liquid chromatography–photodiode array detection.

Methods: After precipitation of the plasma proteins, the supernatant is diluted with deionized water and filled into the narrow–bore tube. Then mg–level of the sorbent is added into the tube. The sorbent is dispersed and moved down through the solution instead of passing the solution from the cartridge. Using an external magnet, the collected nano–sorbents at the bottom of the tube are transferred on top of the solution and released to move down through the solution for three times to increase the extraction efficiency.

Results: The linearity of the assay was ranging from 0.4–500 mg mL-1. The limits of detection and quantification of the method were obtained in the ranges of 0.05–0.07 and 0.16–0.24 mg L-1, respectively. The extraction recoveries were obtained in the range of 31–49%. Intra– and inter–day precisions were calculated and obtained in the ranges of 5–8 and 7%–9% for 0.5 mg L-1 of each analyte, and 5–6 and 6%–8% for 2 mg L-1 of each analyte, respectively.

Conclusion: The proposed method was successfully used in determination of the studied drugs in patient’s plasmas.

Keywords: High–performance liquid chromatography, Magnetic solid phase extraction, Plasma, Atorvastatin, Losartan, Valsartan

Introduction

About 30% of the global morbidity and mortality are caused by cardiovascular diseases each year.1,2 Hypertension, high cholesterol level or diabetes are some factors that increasing the risk of affection to cardiovascular diseases.3,4 All of these factors are caused by stress and unhealthy foods.2 The cardiovascular drugs such as atorvastatin, losartan, valsartan, carvedilol, propranolol, verapamil, etc are used for the treatment of the mentioned effected factors.5 Atorvastatin belongs to a drug class named statins. It is one of the drugs which is used to help low “bad” cholesterol and fats in blood. It works by reducing the amount of cholesterol made by liver and decreases the risk of heart diseases and helps prevent strokes and heart attacks.6 Losartan and valsartan belong to angiotensin-receptor blockers which commonly prescribed for the treatment of hypertension and high blood pressure.7

In order to assay different families of drugs used in cardiovascular therapy, various analytical methods have been developed in pharmaceutical and biological samples. In most of them high performance liquid chromatography (HPLC) equipped with ultraviolet,8 photo diode array (PDA),7,9 fluorescence,1,10 or mass spectrometry11-13 have been used. Other methods include spectrophotometry,14,15 electrochemical method,16 gas chromatography,17 and capillary electrophoresis.18

Sample preparation is an essential step in most analytical procedures which significantly influences the final results of the research, especially in the analysis of biological samples.19 Solid phase extraction (SPE) was introduced in 1970s as a powerful clean–up method.20 This method has drawbacks such as: clogging of cartridges, being time–consuming, necessity of pump usage, low extraction efficiency resulted from particles aggregation and impossibility treatment of large sample volumes treatment.21-23 New SPE methods have attracted special attention in recent years to resolve the mentioned problems. Magnetic solid phase extraction (MSPE) is one of the new SPE procedures which use magnetic sorbents to adsorb analytes. These sorbents can be separated easily using an external magnetic force from an aqueous solution. Then, a suitable solvent is used for desorption of analytes for further determination.19,24 Magnetic nanoparticles (MNPs) are a kind of nanoparticles (NPs, 1–100 nm) which present super-paramagnetism and also possess unique reactivity and large specific surface area due to its nano nature.25 Different NPs like iron, nickel, cobalt, and their oxides26 are used as the core of the sorbents in MSPE that among them Fe3O4 is often–used NPs.27,28 Bare MNPs are seldom directly used in extraction methods because of lack of functional groups to interact with the analytes, aggregation tendency resulting in loss of their magnetism, quick biodegradation, and easily oxidation in air. Thus, MNPs are coated by silane groups for preventing aggregation and oxidation by air and to functionalize of them with different groups which make the sorbents suitable to interact with the analytes.29-31 MNPs are functionalized by groups such as C1832 and C8 alkyl chain,33,34 phenyl,35 graphene,36 etc depending on the analytes being extracted.

In this work, an HPLC–PDA method was developed for the simultaneous determination of some cardiovascular drugs (atorvastatin, losartan, and valsartan) in human plasma samples after MSPE performed in a narrow–bore tube using the synthesized Fe3O4@SiO2@C8 NPs. In order to obtain suitable sensitivity and separation, factors affecting the chromatographic procedure, such as the composition of mobile phase and its flow rate, and temperature were optimized. Furthermore, the effect of various parameters influencing the extraction efficiency was investigated carefully and the suitable conditions were established. The advantages of the proposed method are short time of chromatographic separation, consuming small amount of biological sample, and eliminating pretreatment of the sorbent which is time–consuming and consumes organic solvent. Also, pumping or suction, and clogging the sorbent observed in the conventional format of SPE were resolved.

Materials and Methods

Reagents and standard solutions

All reagents were analytical reagent grade and used without further purification. Atorvastatin (as calcium trihydrate), losartan, and valsartan were provided from Darou Pakhsh Pharmaceutical Company (Tehran, Iran). HPLC–grade water, methanol, and acetonitrile were supplied from Caledon (Canada). Deionized water was from Ghazi Pharmaceutical Company (Tabriz, Iran). Phosphoric acid, triethylamine, ammonia, sodium chloride, pyridine, hydrochloric acid, and sodium hydroxide were from Merck (Darmstadt, Germany). Ferric chloride hexahydrate (FeCl3.6H2O) (99.0%–102.0%) and ferrous sulfate heptahydrate (FeSO4.7H2O) (99.5%–102.0%) were purchased from Merck (Darmstadt, Germany) and used in the synthesis of Fe3O4 NPs. Toluene and ethanol were obtained from Fluka (Switzerland). Octyltrimethoxy silane (OTMOS) and tetraethoxy silane (TEOS) with purity of 96% and 98%, respectively, were purchased from Sigma–Aldrich (St. Louis, MO, USA). A magnet (10 × 10 × 0.5 cm) was used in separation of MNPs. Stock solution of each drug (1000 mg L−1) was prepared in methanol and stored in a refrigerator at 4°C. A working standard solution (20 mg L–1 of each analyte) was prepared in HPLC–grade water by adding appropriate volumes of the stock solutions. This solution was used in preparation of the dilute solutions of the analytes.

Instrumentation

The size and surface morphology of the MNPs were investigated by scanning electron microscopy (SEM) (Tescan, Czech) with an accelerating voltage of 10.0 kV. Fourier transform infrared (FTIR) spectra were recorded using KBr pellets and FT-IR spectrometer (Bruker, USA) in the range of 400–4000 cm-1 with the resolution of 4 cm-1. X-ray diffraction (XRD) patterns of all samples were obtained using a Siemens D500 diffractometer (Germany) at room temperature, operating at a voltage of 35 kV. The experiments were done at a scan rate of 1° min-1 for a scan range of 5 to 80°.

A Hewlett Packard 1090–II HPLC (Palo Alto, CA, USA) equipped with a 10-μL injection loop, a PDA, and a C18 column (25 cm × 4.6 mm i.d.) with a particle size of 5 µm (Alltech, Leonberg, Germany) was used for separation of the analytes. The mobile phase consisted of 0.25%, v/v, triethylamine (adjusted at pH=3.0 by phosphoric acid) and acetonitrile (60:40, v/v) at a flow rate of 1.0 mL min−1. The column temperature was thermostated at 40°C. Detection wavelength was set at 205 nm for losartan and valsartan and 200 nm for atorvastatin. The ChemStation software was used for the HPLC system controlling. An LBS2 ultrasonic bath (FALC Instruments, Treviglio, BG, Italy) was used to degas the mobile phase and deionized water used in synthesis of NPs. A Metrohm pH meter model 654 (Herisau, Switzerland), a Labinco vortex model L46 (The Netherlands) and a D–7200 Hettich centrifuge (Kirchlengern, Germany) were used. A VELP Scientifica heating magnetic stirrer (model ARE, Milano, Italy) was used for stirring in MNPs synthesis procedure.

Synthesis of Fe3O4@SiO2@C8 MNPs

This synthesis consists of 3 steps: synthesis of Fe3O4 NPs, stabilizing of Fe3O4 NPs using TEOS, and coating of Fe3O4@SiO2 NPs by C8 reagent (OTMOS).

Fe3O4 NPs were prepared by co–precipitation of Fe3+ and Fe2+ oxides. Initially, analytical grade FeCl3.6H2O (4.86 g) and FeSO4.7H2O (3.34 g) were added to 50 mL deionized water placed into the ultrasonic bath for 10 minutes. Then this solution was transferred into a water bath thermostated at a temperature of 100°C and vigorously stirred. After complete dissolving iron salts, 12 mL concentrated ammonia (d = 0.91 mg mL-1, 25%, w/v) was added and continued to stir for 2 hours in the mentioned temperature. By adding ammonia, the color of mixture changed to dark black. This solution was cooled and the obtained black NPs were washed until neutral pH with a mixture of ethanol: water (50:50, v/v) in the presence of magnetic field. Finally iron oxide NPs were washed with ethanol and dried in an oven at a temperature of 80°C.

The obtained MNPs from the previous step were suspended into 300 mL mixture of ethanol and deionized water (4:1, v/v) using ultrasonic bath for 15 minutes. Then, 15 mL concentrated ammonia and 6.3 mL TEOS continuously added into the suspension. The mixture was stirred for 12 hours at 40°C and finally the Fe3O4@SiO2 NPs were separated from the solution using the magnet. The obtained MNPs were dried in an oven at a temperature of 60°C.37

Finally for interaction of the MNPs by the analytes, one more step was required too. In this step, the obtained Fe3O4@SiO2 NPs from the previous step were suspended into 50 mL toluene consisted of 2 mL OTMOS by sonicating. After 15 min ultrasonication, 400 µL pyridine as a catalyst was added to the mixture and refluxed for 8 h at a temperature of 120°C. The modified NPs were separated using the magnet and washed by toluene, methanol, and water, respectively, to remove the excess of C8 reagent. Finally the produced MNPs were died in an oven at a temperature of 60°C for 1 hour. This step was done according to the procedure reported by Tang et al with partial modification.29 It is noted that in this study OTMOS was used instead of phenyltrimethoxy silane. Synthesis steps of the MNPs are shown schematically in Scheme 1.

Scheme 1 .


Scheme 1

Synthesis of MNPs. Fe3O4 (a), Fe3O4@SiO2 (b), and Fe3O4@SiO2@C8 (c).

Samples

Drugs–free plasma sample (blank plasma) of a healthy human was obtained from the Iranian Blood Transfusion Organization (Tabriz, Iran) and was stored at -20°C before being spiked and used in optimization of the method. Four plasma samples from the patients who received one of the studied drugs (three of them have received atorvastatin, and one of them has received valsartan) and also 3 other plasma samples from the healthy individuals which have not received any of the studied drugs were obtained.

Microextraction procedure

For precipitating the proteins, to 0.5 mL plasma (sample or blank plasma spiked with 1 mg L-1 of each analyte), 1 mL methanol was added. After vortexing for 1 minute, the mixture was centrifuged at 7000 rpm for 5 minutes. The supernatant was transferred into a 12–mL test tube and 8.5 mL phosphate buffer (0.1 M, pH = 3) was added to it. Then 2 g NaCl (20%, w/v) was added and vortexed to dissolve. This solution was filled into a home–made set–up. The set–up consisted of a narrow–bore glass tube (60×0.4 cm i.d.) which its head was funnel shaped and its end was connected to a ground glass joint. The tube was connected to a 5–mL ground glass joint test tube with the conical bottom. The volume of this set–up was about 12.5 mL. In the following the synthesized MNPs (20 mg) were added to the solution and the sorbent particles were dispersed into the aqueous solution and moved down through the tube under the gravity force and collected in the bottom of the test tube. Using an external magnet, the collected MNPs at the bottom of the tube were transferred on the top the solution and released to move down through the solution for three repeated times. After this step, the test tube was disconnected. By a 5–mL syringe, the supernatant solution was removed completely in the presence of magnetic field. In the next step, 50 µL methanol as an elution solvent was used for eluting the analytes from the solid sorbent. This mixture was vortexed for 2 minutes and the solution separated from the sorbent by the magnet was injected into the separation system for analysis. Extraction and preconcentration procedure is shown schematically in Scheme 2.

Scheme 2 .


Scheme 2

Extraction and preconcentration procedure.

Results and Discussion

Characterization of the sorbent

The characterization of MNPs is usually accomplished using techniques such as XRD, SEM, and FTIR.

The XRD patterns of Fe3O4, Fe3O4@SiO2, and Fe3O4@SiO2@C8 are compared in Figure 1 which display several relatively strong reflection peaks in 2θ region of 5-80°. The six characteristic peaks for Fe3O4 (2θ=30.007, 35.601, 43.239, 53.782, 57.372, and 63.058°) are observed which marked by their indices (220, 311, 400, 422, 511, and 440). The peak positions are unchanged upon coating of SiO2 and C8, indicating that the crystalline structure of the magnetite is essentially maintained.38

Figure 1.

Figure 1

XRD patterns of Fe3O4 (a), Fe3O4@SiO2 (b), and Fe3O4@SiO2@C8 (c).

Figure 2 shows the FT-IR spectra of Fe3O4, Fe3O4@SiO2, and Fe3O4@SiO2@C8. The strong peak around 570 cm-1 is attributed to the characteristic absorbance band of Fe-O in Fe3O4 (Figure 2a). In comparison to Figure 2a, Figure 2b has new peaks at 1052 cm-1 (Si-O in SiO2 stretching vibration) and 1626 cm-1 and 3419 cm-1 which are related to O-H. A peak at 2923 cm-1 in Figure 2c is related to alkane C-H that proves the sticking of C8 to Fe3O4@SiO2.

Figure 2.

Figure 2

FTIR spectra of Fe3O4 (a), Fe3O4@SiO2 (b), and Fe3O4@SiO2@C8 (c).

The morphological characteristics (size and shape) of the magnetic Fe3O4@SiO2@C8 indicated by SEM are shown in Figure 3 which spherical shape of the MNPs can be observed with an average diameter of 35 nm. The most distribution of MNPs based on Figure 3b is in the range of 30-40 nm. Also, the SEM micrograph shows some agglomerates.

Figure 3.

Figure 3

SEM image of Fe3O4@SiO2@C8 (a), and size distribution (b).

Optimization of the extraction conditions

In order to find the best conditions for the extraction and preconcentration of the studied drugs, different parameters affecting the extraction efficiency were investigated in details. These parameters were amount of the sorbent, ionic strength of the solution, kind and volume of the elution solvent, extraction numbers, and ph.

Study of ionic strength

The effect of ionic strength on efficiency of the extraction method can be explained in 2 ways: (a) viscosity of the aqueous solution increases in high concentration of salt which, in turns, results in the decreased diffusion coefficients of the analytes and the reduced extraction efficiency, and (b) by adding a salt, solubility of the analytes in the aqueous phase decreases because of increasing the polarity of the aqueous solution, so extraction efficiency can be Improved. This phenomenon is called “salting out” effect. The ionic strength effect on the extraction efficiency was investigated in the presence of 0%, 5%, 10%, 15%, 20%, and 25%, w/v, NaCl. By increasing the salt concentration, the analytical signals increased up to 20%, w/v, because of salting out effect, and then decreased or remained constant at 25%, w/v, as a result of aqueous solution viscosity increasing. With regard to these results (Figure 4), the further experiments were performed in the presence of 20%, w/v, NaCl.

Figure 4.

Figure 4

Study of ionic strength: Extraction conditions: sample, 0.5 mL drug–free plasma was spiked with 1 mg L–1 of each analyte. After precipitating its proteins by 1 mL methanol, the supernatant was diluted with phosphate buffer (0.1 M, pH=3) to make its volume 10 mL; extraction numbers, 3; elution solvent, 100 µL methanol; and vortex time, 2 min; sorbent amount: 20 mg. The error bars indicate standard deviation of 3 repeated determinations.

Study of aqueous solution pH

For adsorption of the studied analytes onto the sorbent containing C8 groups (non–polar groups), the analytes should be in molecular forms. For finding the optimum pH in extraction of the analytes, different pH values ranged in 2-10 were tested. In each case, 8.5 mL of a universal buffer (Robinson buffer, 0.12 M) in the mentioned pHs was used. The results in Figure 5 show that the high extraction efficiency of the studied analytes is obtained at pH 3. Regarding to pKa of the studied drugs (valsartan, 4.37; losartan, 5.5; and atorvastatin, 4.3),39 extraction of the analytes in acidic pHs (lower than 4) is logical. Decrease of peak areas at pH = 2 may be related to the sorbent decomposition. So, phosphate buffer (C=0.1 M) with a pH of 3 was used for the next steps.

Figure 5.

Figure 5

Influence of pH on the extraction efficiency of the method. Extraction conditions: NaCl concentration: 20%, w/v, and 8.5 mL Robinson buffer (C=0.12 M) was used instead of phosphate buffer. Other extraction conditions are the same as used in Figure 4.

Optimization of the sorbent amount

Different amounts of the sorbent (10, 20, 30, 40, and 50 mg) were tested to optimize the sorbent amount. The results in Figure 6 indicate that peak areas increase up to 20 mg and then reach the constant amounts. Therefore 20 mg was selected as the optimal amount of the sorbent for the subsequent experiments.

Figure 6.

Figure 6

Effect of the sorbent amount on the method efficiency. Extraction conditions are the same as used in Figure 4 except phosphate buffer (0.1 M, pH=3) was used instead of Robinson buffer.

Study of extraction numbers

After adding the sorbent into the solution placed in the extraction device, it moves through the tube based on gravity force. Using an external magnet, the collected sorbent at the bottom of the tube was transferred on top of the solution and let to move again through the tube. In this study, the number of times that the sorbent moved by the magnet on top of the solution is called as the extraction numbers. It is reasonable that high extraction numbers lead to high analytical signals. For finding the optimal extraction numbers, 0, 1, 2, 3, 4, and 5 times were tested. Figure 7 indicates that the analytical signals increase by increasing extraction numbers up to 3 and then remain constant. Hence 3 times was selected as the optimal numbers for the extraction of the studied drugs.

Figure 7.

Figure 7

Optimization of extraction numbers. Extraction conditions are the same as used in Figure 4, except 20 mg of the sorbent was used.

Selection of elution solvent kind and its volume

Finding a suitable solvent for elution of the analytes sorbed onto the sorbent is an important step in the proposed method. For investigating this parameter, different elution solvents including methanol, acetonitrile, sodium bicarbonate solution (0.2 M), ammonia solution (0.2 M), and mixtures of methanol: 0.2 M ammonia solution (70:30, v/v), and methanol: 0.2 M sodium bicarbonate solution (70:30, v/v) were tested. Comparison of the peak areas obtained using different solvents indicates that methanol, acetonitrile, and mixture of methanol: sodium bicarbonate solution gave the highest extraction efficiencies for the target analytes among the selected solvents (Figure 8A). However methanol was chosen for the further studies.

Figure 8.

Figure 8

Selection of elution solvent type (A), and its volume (B). Extraction conditions are the same as used in Figure 4, except extraction numbers of 3 were used.

Also, volume of the elution solvent (methanol) can be another parameter that should be considered. For optimization of this parameter 30, 50, 75, 100, and 125 µL methanol were tested. According to the obtained data in Figure 8B, in the case of 30 µL the highest analytical signals are achieved but repeatability of the method is not satisfied. This can be concluded from the error bars. Also, separation of the sorbent from the solution was difficult. So, 50 µL was chosen as the optimal volume of the elution solvent.

Optimization of vortex time

In this study, different vortexing times (0.5, 1.0, 1.5, 2.0, and 2.5 minutes) were investigated under a constant rotational speed for dissolving the dried analytes in methanol. The extraction efficiency increased up to 1.5 minutes and after that, no considerable change was observed. Therefore, 2 minutes as the vortexing time was selected for the further studies.

Investigation of other drugs interferences

An interesting aspect of each analytical method is determination of trace concentration of analytes in the presence of the other species that their presence in real samples is plausible. So the effect of different drugs on the relative recoveries of the studied analytes was investigated by spiking 2 mg L-1 of each amiodarone, propranolol, verapamil, carvedilol, atenolol, acetaminophen, ibuprofen, diclofenac, and amoxicillin into the blank plasma fortified with 500 µg L-1 of each studied drug. The obtained results are gathered in Table 1. As it can be seen the obtained relative recovery are between 93% and 104%. These results indicate that the proposed method can be used for the determination of the analytes in plasma in the presence of other selected drugs.

Table 1. Interferences study .
Drug Relative recovery (%) ± standard deviation (n=3)
Losartan Valsartan Atorvastatin
Amiodarone 94 ± 2 97 ± 4 96 ± 3
Propranolol 97 ± 3 97 ± 2 95 ± 3
Verapamil 102 ± 3 104 ± 5 96 ± 2
Carvedilol 96 ± 4 95 ± 3 97 ± 1
Atenolol 96 ± 3 93 ±4 95 ± 3
Acetaminophen 96 ± 2 97 ± 1 98 ± 3
Ibuprofen 97 ± 4 94 ± 4 93 ± 3
Diclofenac 99 ± 4 97 ± 3 97 ± 2
Amoxicillin 101 ± 2 98 ± 3 99 ± 2

Quantitative features of the method

To evaluate the proposed method, linear range of the calibration graph, coefficient of determination (R2), limit of detection (LOD), limit of quantification (LOQ), relative standard deviation (RSD), and extraction recovery (ER) were investigated under the optimized conditions. The results are listed in Table 2. The linearity of the assay was evaluated by constructing the calibration curves with different concentrations of the analytes (n=11) ranging from 0.4–500 mg mL-1. The R2 for losartan, valsartan, and atorvastatin were 0.997, 0.998, and 0.998, respectively. The LODs and LOQs of the method were estimated based on signal intensity 3 and 10 times more than baseline noise (S/N=3) and (S/N=10), respectively. Based on these definitions, the LODs and LOQs were obtained in the ranges of 0.05–0.07 and 0.16–0.24 mg L-1, respectively. It is noted that therapeutic plasma concentrations of atorvastatin, losartan, and valsartan are 0.2–1.2, 0.8–6, and 0.032–0.103 mg L−1, respectively which are higher than the method LODs, except for atorvastatin in low range.9,40 The ERs were obtained in the range of 31%-49%, which are acceptable in plasma matrix. For assessment of the method precision, replicated analysis of the analytes at two concentrations (0.5 and 2 mg L-1 of each analyte in plasma) were done within a same day (n=6) and different days (n=3). Intra– and inter–day RSDs were calculated and obtained in the ranges of 5–8 and 7%–9% for 0.5 mg L-1, and 5–6 and 6%–8% for 2 mg L-1, respectively.

Table 2. Analytical features of the proposed MSPE–HPLC–PDA method in human plasma .
Analytes LOD a (mg L −1 ) LOQ b (mg L −1 ) LR c (mg L −1 ) R 2d Calibration curve equation ER±SD e RSD % f RSD % g
Intra–day
(n=6)
Inter–day
(n=3)
Intra–day
(n=6)
Inter–day
(n=3)
Losartan 0.07 0.24 0.4–500 0.997 Area = 128.38C+39.362 31 ± 5 8 9 6 8
Valsartan 0.07 0.23 0.4–500 0.998 Area = 461.18C+54.632 38 ± 5 7 7 6 7
Atorvastatin 0.05 0.16 0.4–500 0.998 Area = 786.35C+54.631 49 ± 4 5 7 5 6

aLimit of detection, (S/N = 3), bLimit of quantification, (S/N = 10), c Linear range, d Coefficient of determination, eExtraction recovery ± standard deviation (n= 3), fRelative standard deviation (C = 0.5 mg L-1 of each analyte), gRelative standard deviation (C = 2 mg L-1 of each analyte).

Plasma samples analysis

The proposed method was applied in the analysis of plasma samples of the patients under cardiovascular treatment (four plasma samples from the patients who received atorvastatin and valsartan orally) for demonstrating the applicability of the method. Also three other plasma samples obtained from healthy volunteers received none of the studied drugs were analyzed by the method. In the cases of drug–free plasma samples and plasma of the patient received atorvastatin, no peak was found in the retention times of the analytes. In patient sample, the found concentration was calculated 0.72 mg L−1 for valsartan sample. Typical HPLC–PDA chromatograms corresponding to a standard solution of the analytes (20 mg L−1 of each), drug–free plasma sample, and plasmas of the patients under treatment with valsartan are shown in Figure 9.

Figure 9.

Figure 9

HPLC–PDA chromatograms of: (A) standard solution (20 mg L-1 of each analyte), (B) plasma sample of patient treated with valsartan, and (C) drug–free plasma of a healthy person. In all cases, except (A) the proposed method was performed and the enriched analytes were injected into the separation system. In chromatogram (A) direct injection was carried out. Detection wavelength was 205 nm. Peaks identification: (1) losartan, (2) valsartan, and (3) atorvastatin.

Conclusion

In this study, a new version of MSPE performed in a narrow–bore tube was proposed for the simultaneous determination of atorvastatin, losartan, and valsartan (cardiovascular drugs) in human plasma prior to their HPLC–PDA analysis. The major advantages of the method are its short separation time (<8 minutes), small quantity of the required solvents, and avoiding cartridge format. There are other exclusive advantages in this method compared to traditional SPE method such as elimination of vacuum pump and conditioning step of the sorbent. Also, the analytical features of the method show satisfactory linearity, precision, LOD, and ER under the optimized conditions.

Acknowledgments

The authors thank the Research Council of University of Tabriz and Iran National Science Foundation (Science Research No. PHD 96000434) for the financial support.

Conflict of Interest

There is no conflict of interest for this work; all authors are in agreement with the submission of this research paper to this journal.

Ethical Issues

Not applicable.

References

  • 1.Gonzalez O, Iriarte G, Ferreirós N, Maguregui MI, Alonso RM, Jiménez RM. Optimization and validation of a spe-hplc-pda-fluorescence method for the simultaneous determination of drugs used in combined cardiovascular therapy in human plasma. J Pharm Biomed Anal. 2009;50(4):630–9. doi: 10.1016/j.jpba.2008.10.037. [DOI] [PubMed] [Google Scholar]
  • 2.De Backer G, Ambrosioni E, Borch-Johnsen K, Brotons C, Cifkova R, Dallongeville J. et al. European guidelines on cardiovascular disease prevention in clinical practice third joint task force of european and other societies on cardiovascular disease prevention in clinical practice (constituted by representatives of eight societies and by invited experts) Atherosclerosis. 2004;173(2):381–91. [PubMed] [Google Scholar]
  • 3. Assal J, Groop L. Definition, diagnosis and classification of diabetes mellitus and its complications. Geneva, Switzerland: World Health Organization (WHO); 1999.
  • 4.Grundy SM, Brewer HB Jr, Cleeman JI, Smith SC Jr, Lenfant C. Definition of metabolic syndrome: report of the national heart, lung, and blood institute/american heart association conference on scientific issues related to definition. Circulation. 2004;109(3):433–8. doi: 10.1161/01.ATV.0000111245.75752.C6. [DOI] [PubMed] [Google Scholar]
  • 5.Chrysant SG, Chrysant GS, Dimas B. Current and future status of beta‐blockers in the treatment of hypertension. Clin Cardiol. 2008;31(6):249–52. doi: 10.1002/clc.20249. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Kodama Y, Kitta Y, Nakamura T, Takano H, Umetani K, Fujioka D. et al. Atorvastatin increases plasma soluble fms-like tyrosine kinase-1 and decreases vascular endothelial growth factor and placental growth factor in association with improvement of ventricular function in acute myocardial infarction. J Am Coll Cardiol. 2006;48(1):43–50. doi: 10.1016/j.jacc.2006.03.035. [DOI] [PubMed] [Google Scholar]
  • 7.Vishnuvardhan C, Radhakrishnanand P, Navalgund SG, Atcha KR, Satheeshkumar N. Rp-hplc method for the simultaneous estimation of eight cardiovascular drugs. Chromatographia. 2014;77(3-4):265–75. doi: 10.1007/s10337-013-2598-0. [DOI] [Google Scholar]
  • 8.Soltani S, Jouyban A. Optimization and validation of an isocratic hplc-uv method for the simultaneous determination of five drugs used in combined cardiovascular therapy in human plasma. Asian J Chem. 2011;23(4):1728–1734. [Google Scholar]
  • 9.Farajzadeh MA, Khorram P, Pazhohan A. Simultaneous determination of atorvastatin and valsartan in human plasma by solid-based disperser liquid–liquid microextraction followed by high-performance liquid chromatography–diode array detection. J Chromatogr B Analyt Technol Biomed Life Sci. 2016;1017-1018:62–9. doi: 10.1016/j.jchromb.2016.02.039. [DOI] [PubMed] [Google Scholar]
  • 10.Macek J, Klima J, Ptácek P. Rapid determination of valsartan in human plasma by protein precipitation and high-performance liquid chromatography. J Chromatogr B Analyt Technol Biomed Life Sci. 2006;832(1):169–72. doi: 10.1016/j.jchromb.2005.12.035. [DOI] [PubMed] [Google Scholar]
  • 11.Kristoffersen L, Øiestad EL, Opdal MS, Krogh M, Lundanes E, Christophersen AS. Simultaneous determination of 6 beta-blockers, 3 calcium-channel antagonists, 4 angiotensin-ii antagonists and 1 antiarrhytmic drug in post-mortem whole blood by automated solid phase extraction and liquid chromatography mass spectrometry Method development and robustness testing by experimental design. J Chromatogr B Analyt Technol Biomed Life Sci. 2007;850(1-2):147–60. doi: 10.1016/j.jchromb.2006.11.030. [DOI] [PubMed] [Google Scholar]
  • 12.Gadepalli SG, Deme P, Kuncha M, Sistla R. Simultaneous determination of amlodipine, valsartan and hydrochlorothiazide by lc-esi-ms/ms and its application to pharmacokinetics in rats. J Pharm Anal. 2014;4(6):399–406. doi: 10.1016/j.jpha.2013.12.003. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Levi M, Wuerzner G, Ezan E, Pruvost A. Direct analysis of valsartan or candesartan in human plasma and urines by on-line solid phase extraction coupled to electrospray tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci. 2009;877(10):919–26. doi: 10.1016/j.jchromb.2009.02.030. [DOI] [PubMed] [Google Scholar]
  • 14.Tatar S, Sağlık S. Comparison of uv-and second derivative-spectrophotometric and lc methods for the determination of valsartan in pharmaceutical formulation. J Pharm Biomed Anal. 2002;30(2):371–5. doi: 10.1016/s0731-7085(02)00360-6. [DOI] [PubMed] [Google Scholar]
  • 15.Patil PR, Rakesh SU, Dhabale PN, Burade KB. Simultaneous uv spectrophotometric method for estimation of losartan potssium and amlodipine besylate in tablet dosage form. Asian J Res Chem. 2009;2(2):183–7. [Google Scholar]
  • 16.Bagoji AM, Patil SM, Nandibewoor ST. Electroanalysis of cardioselective beta-adrenoreceptor blocking agent acebutolol by disposable graphite pencil electrodes with detailed redox mechanism. Cogent Chem. 2016;2(1):1172393. doi: 10.1080/23312009.2016.1172393. [DOI] [Google Scholar]
  • 17.Gibson DM, Stern RH, Abel RB, Whitfield LR. Absolute bioavailability of atorvastatin in man. Pharm Res. 1997;14(2):253. [Google Scholar]
  • 18.Williams RC, Alasandro MS, Fasone VL, Boucher RJ, Edwards JF. Comparison of liquid chromatography, capillary electrophoresis and super-critical fluid chromatography in the determination of losartan potassium drug substance in cozaar tablets. J Pharm Biomed Anal. 1996;14(11):1539–46. doi: 10.1016/0731-7085(96)01740-2. [DOI] [PubMed] [Google Scholar]
  • 19.Wierucka M, Biziuk M. Application of magnetic nanoparticles for magnetic solid-phase extraction in preparing biological, environmental and food samples. Trends Anal Chem. 2014;59(2):50–8. doi: 10.1016/j.trac.2014.04.007. [DOI] [Google Scholar]
  • 20.Andrade-Eiroa A, Canle Lopez M, Leroy Cancellieri V, Cerdà V. Solid-phase extraction of organic compounds: A critical review: (part i) Trends Anal Chem. 2015;80:641–54. doi: 10.1016/j.trac.2015.08.015. [DOI] [Google Scholar]
  • 21.Fontana AR, Camargo A, Martinez LD, Altamirano JC. Dispersive solid-phase extraction as a simplified clean-up technique for biological sample extracts Determination of polybrominated diphenyl ethers by gas chromatography–tandem mass spectrometry. J Chromatogr A. 2011;1218(18):2490–6. doi: 10.1016/j.chroma.2011.02.058. [DOI] [PubMed] [Google Scholar]
  • 22.Rial-Otero R, Gaspar EM, Moura I, Capelo JL. Chromatographic-based methods for pesticide determination in honey: An overview. Talanta. 2007;71(2):503–14. doi: 10.1016/j.talanta.2006.05.033. [DOI] [PubMed] [Google Scholar]
  • 23.Sajid M, Basheer C. Layered double hydroxides: Emerging sorbent materials for analytical extractions. Trends Anal Chem. 2016;75:174–82. doi: 10.1016/j.trac.2015.06.010. [DOI] [Google Scholar]
  • 24.Naing NN, Yau Li SF, Lee HK. Magnetic micro-solid-phase-extraction of polycyclic aromatic hydrocarbons in water. J Chromatogr A. 2016;1440:23–30. doi: 10.1016/j.chroma.2016.02.046. [DOI] [PubMed] [Google Scholar]
  • 25.Rocío-Bautista P, Pino V, Ayala JH, Pasán J, Ruiz-Pérez C, Afonso AM. A magnetic-based dispersive micro-solid-phase extraction method using the metal-organic framework hkust-1 and ultra-high-performance liquid chromatography with fluorescence detection for determining polycyclic aromatic hydrocarbons in waters and fruit tea infusions. J Chromatogr A. 2016;1436:42–50. doi: 10.1016/j.chroma.2016.01.067. [DOI] [PubMed] [Google Scholar]
  • 26.Li XS, Zhu GT, Luo YB, Yuan BF, Feng YQ. Synthesis and applications of functionalized magnetic materials in sample preparation. Trends Anal Chem. 2013;45:233–47. doi: 10.1016/j.trac.2012.10.015. [DOI] [Google Scholar]
  • 27.Kazemi E, Dadfarnia S, Haji Shabani AM, Abbasi A, Rashidian Vaziri MR, Behjat A. Iron oxide functionalized graphene oxide as an efficient sorbent for dispersive micro-solid phase extraction of sulfadiazine followed by spectrophotometric and mode-mismatched thermal lens spectrometric determination. Talanta. 2016;147:561–8. doi: 10.1016/j.talanta.2015.10.033. [DOI] [PubMed] [Google Scholar]
  • 28.Amoli-Diva M, Pourghazi K, Hajjaran S. Dispersive micro-solid phase extraction using magnetic nanoparticle modified multi-walled carbon nanotubes coupled with surfactant-enhanced spectrofluorimetry for sensitive determination of lomefloxacin and ofloxacin from biological samples. Mater Sci Eng C mater Biol Apple. 2016;60:30–6. doi: 10.1016/j.msec.2015.11.013. [DOI] [PubMed] [Google Scholar]
  • 29.Tang M, Wang Q, Jiang M, Xu L, Shi ZG, Zhang T. et al. Magnetic solid-phase extraction based on methylcellulose coated-fe3o4-sio2-phenyl for hplc-dad analysis of sildenafil and its metabolite in biological samples . Talanta. 2014;130:427–32. doi: 10.1016/j.talanta.2014.07.006. [DOI] [PubMed] [Google Scholar]
  • 30.Aguilar-Arteaga K, Rodriguez JA, Barrado E. Magnetic solids in analytical chemistry: A review. Anal Chim Acta. 2010;674(2):157–65. doi: 10.1016/j.aca.2010.06.043. [DOI] [PubMed] [Google Scholar]
  • 31. Rocío‐Bautista P, Pino V. Extraction methods facilitated by the use of magnetic nanoparticles. Analytical separation science. 1st ed. U.S.: Wiley-VCH Verlag GmbH & Co. KGaA; 2015.
  • 32.Sha Y, Deng C, Liu B. Development of C18-functionalized magnetic silica nanoparticles as sample preparation technique for the determination of ergosterol in cigarettes by microwave-assisted derivatization and gas chromatography/mass spectrometry. J Chromatogr A. 2008;1198-1199:27–33. doi: 10.1016/j.chroma.2008.05.049. [DOI] [PubMed] [Google Scholar]
  • 33.Chen H, Xu X, Yao N, Deng C, Yang P, Zhang X. Facile synthesis of c8‐functionalized magnetic silica microspheres for enrichment of low‐concentration peptides for direct maldi‐tof ms analysis. Proteomics. 2008;8(14):2778–84. doi: 10.1002/pmic.200700892. [DOI] [PubMed] [Google Scholar]
  • 34.Liu S, Li Y, Deng C, Mao Y, Zhang X, Yang P. Preparation of magnetic core‐mesoporous shell microspheres with c8‐modified interior pore‐walls and their application in selective enrichment and analysis of mouse brain peptidome. Proteomics. 2011;11(23):4503–13. doi: 10.1002/pmic.201100101. [DOI] [PubMed] [Google Scholar]
  • 35.Saraji M, Khaje N. Phenyl‐functionalized silica‐coated magnetic nanoparticles for the extraction of chlorobenzenes, and their determination by gc‐electron capture detection. J Sep Sci. 2013;36(6):1090–6. doi: 10.1002/jssc.201200863. [DOI] [PubMed] [Google Scholar]
  • 36.Kazemi E, Dadfarnia S, Haji Shabani AM. Dispersive solid phase microextraction with magnetic graphene oxide as the sorbent for separation and preconcentration of ultra-trace amounts of gold ions. Talanta. 2015;141:273–8. doi: 10.1016/j.talanta.2015.04.024. [DOI] [PubMed] [Google Scholar]
  • 37.Mehdinia A, Baradaran Kayyal T, Jabbari A, Aziz-Zanjani MO, Ziaei E. Magnetic molecularly imprinted nanoparticles based on grafting polymerization for selective detection of 4-nitrophenol in aqueous samples. J Chromatogr A. 2013;1283:82–8. doi: 10.1016/j.chroma.2013.01.093. [DOI] [PubMed] [Google Scholar]
  • 38.Li Y, Li X, Chu J, Dong C, Qi J, Yuan Y. Synthesis of core-shell magnetic molecular imprinted polymer by the surface raft polymerization for the fast and selective removal of endocrine disrupting chemicals from aqueous solutions. Environ Pollut. 2010;158(6):2317–23. doi: 10.1016/j.envpol.2010.02.007. [DOI] [PubMed] [Google Scholar]
  • 39. Drugs. http://www.Drugbank.Ca/drugs. Accessed November 2017.
  • 40.Regenthal R, Krueger M, Koeppel C, Preiss R. Drug levels: Therapeutic and toxic serum/plasma concentrations of common drugs. J Clin Monit Comput. 1999;15(7-8):529–44. doi: 10.1023/a:1009935116877. [DOI] [PubMed] [Google Scholar]

Articles from Advanced Pharmaceutical Bulletin are provided here courtesy of Tabriz University of Medical Sciences