Skip to main content
Wiley Open Access Collection logoLink to Wiley Open Access Collection
. 2019 Jan 18;32(3):e4061. doi: 10.1002/nbm.4061

Coupling between cerebral blood flow and cerebral blood volume: Contributions of different vascular compartments

Roman Wesolowski 1,2,*, Nicholas P Blockley 1,3,*, Ian D Driver 1,4, Susan T Francis 1, Penny A Gowland 1,
PMCID: PMC6492110  PMID: 30657208

Abstract

A better understanding of the coupling between changes in cerebral blood flow (CBF) and cerebral blood volume (CBV) is vital for furthering our understanding of the BOLD response. The aim of this study was to measure CBF‐CBV coupling in different vascular compartments during neural activation. Three haemodynamic parameters were measured during a visual stimulus. Look‐Locker flow‐sensitive alternating inversion recovery was used to measure changes in CBF and arterial CBV (CBVa) using sequence parameters optimized for each contrast. Changes in total CBV (CBVtot) were measured using a gadolinium‐based contrast agent technique. Haemodynamic changes were extracted from a region of interest based on voxels that were activated in the CBF experiments. The CBF‐CBVtot coupling constant α tot was measured as 0.16 ± 0.14 and the CBF‐CBVa coupling constant α a was measured as 0.65 ± 0.24. Using a two‐compartment model of the vasculature (arterial and venous), the change in venous CBV (CBVv) was predicted for an assumed value of baseline arterial and venous blood volume. These results will enhance the accuracy and reliability of applications that rely on models of the BOLD response, such as calibrated BOLD.

Keywords: arterial spin labelling, BOLD, CBF‐CBV coupling, cerebral blood volume, fMRI


Abbreviations used

ASL

arterial spin labelling

BOLD

blood oxygenation level dependent

CASL

continuous arterial spin labelling

CBF

cerebral blood flow

CBV

cerebral blood volume

EPI

echo planar imaging

GBCA

gadolinium‐based contrast agent

ITS‐FAIR

inflow turbo‐sampling echo planar imaging flow‐sensitive alternating inversion recovery

iVASO

inflow‐based vascular space occupancy

LL‐EPI

Look‐Locker echo planar imaging

LL‐FAIR

Look‐Locker flow‐sensitive alternating inversion recovery

PASL

pulsed arterial spin labelling

PCASL

pseudocontinuous arterial spin labelling

SENSE

sensitivity encoding

SNR

signal to noise ratio

VASO

vascular space occupancy

VENC

velocity encoding

VERVE

venous refocusing for volume estimation

1. INTRODUCTION

The relationship between changes in cerebral blood flow (CBF) and cerebral blood volume (CBV) is critical for an accurate understanding of the haemodynamics that underlie blood oxygenation level dependent (BOLD) fMRI, and a greater understanding of cerebral haemodynamics will lead to more precise quantification of the BOLD response.1, 2 Early studies suggested that the majority of CBV change in response to neuronal activation occurs in venous vessels.3, 4 This led to the adoption of a CBF‐CBV coupling model based on a power law relationship that was characterized using PET measurements of CBF and total CBV (CBVtot).5 However, it is now well known that arterial CBV (CBVa) also increases on activation, and that this occurs to a much greater degree than total CBV, despite the lower baseline CBV of the arterial compartment.6, 7, 8 Therefore, the use of a CBF‐CBVtot coupling constant will overestimate changes in venous CBV (CBVv). This led to measurements of a CBF‐CBVv coupling constant using the CBVv sensitive venous refocusing for volume estimation (VERVE) technique.9, 10 Despite this, the coupling between CBF and CBVa is still poorly understood in humans, with the majority of research having been performed in rats.6, 7 Whilst changes in CBVa are typically invisible in the context of standard BOLD fMRI, they become significant in studies utilizing intravascular contrast agents11 or hypoxic hypoxia,12 where an arterial signal change occurs due to the presence of paramagnetic contrast agent or deoxyhaemoglobin, respectively, in the arterial blood volume, the latter having implications for the application of these methods in cerebrovascular disease, where patients may have a reduced arterial oxygen saturation.

One reason why there is only a small number of published studies examining the relationship between these parameters is the limited number of techniques for measuring CBVtot, CBVa and CBVv in humans. Fractional changes in CBVtot (ΔCBVtot) during a stimulus have been measured via an infusion of a gadolinium‐based contrast agent (GBCA).13, 14, 15 Such experiments rely on measuring changes in the stimulus evoked BOLD response as a function of intravascular contrast agent concentration, which can either be increased using an extended infusion, or decreased by clearance of a bolus of contrast agent via the kidneys.16 This is in contrast to dynamic susceptibility contrast based techniques that are not generally temporally resolved and are more commonly used to measure absolute resting CBVtot. Vascular space occupancy (VASO) has also been shown to provide a method for the assessment of total CBV.17 However, it is not possible to measure ΔCBVtot using VASO without prior knowledge of the baseline CBVtot, thus making this technique unsuitable for the study of CBF‐CBVtot coupling. Arterial spin labelling (ASL)‐based approaches have emerged for the measurement of CBVa; these include inflow‐based VASO (iVASO)18 and Look‐Locker flow‐sensitive alternating inversion recovery (LL‐FAIR).8 LL‐FAIR combines the FAIR ASL technique with Look‐Locker echo planar imaging (LL‐EPI) sampling19 to sensitize the signal to either CBF using vascular crushing20 or CBVa,8 depending on the sequence parameters. This technique is also presented in the literature as ITS‐FAIR (inflow turbo‐sampling EPI flow‐sensitive alternating inversion recovery)21 and QUASAR (quantitative signal targeting with alternating radio frequency labelling of arterial regions),22 the latter requiring the subtraction of scans with and without vascular crushing to estimate CBVa. Since the LL‐FAIR technique is also capable of measuring transit time of labelled blood, it is also able to account for changes in transit time that may occur during neuronal activation. LL‐FAIR also has a higher signal to noise ratio (SNR) per unit time for measurement of perfusion than conventional FAIR.21 CBVv measurements have been made using the VERVE technique23 or hyperoxia BOLD contrast24 methods. However, VERVE is hampered by assumptions regarding oxygenation changes during activation and hyperoxia BOLD contrast by relatively low SNR.

In this study, LL‐FAIR‐based measurements of CBF and CBVa are acquired alongside estimates of ΔCBVtot using a GBCA technique. The relationship between the resultant haemodynamic parameters is assessed using a power law relationship, building upon early studies of CBF‐CBV coupling,5 the calibrated BOLD method1, 2 and BOLD modelling studies.3, 4 This analysis yields CBF‐CBVa and CBF‐CBVtot coupling constants. These measurements are also used to predict the change in CBVv for an assumed arterial and venous volume fraction.

2. THEORY

2.1. LL‐FAIR for measurement of CBF

LL‐FAIR combines a FAIR ASL labelling scheme with LL‐EPI sampling. The sequence can be sensitized to CBF by using an initial inversion delay (T I) to allow inflowing blood to arrive at the imaging plane (T I = 600 ms) followed by low flip angle pulses (θ = 35°) for the EPI readouts with a time interval (T A = 350 ms) such that the perfusion signal is not fully suppressed and can be sampled multiple times Figure 1B). Vascular crushing is added to minimize any CBVa signal contribution from the macrovasculature.

Figure 1.

Figure 1

A, overview of the experimental protocol including visual stimulus blocks (red lines), contrast agent injections (arrow Gd) and experimental details. B, example pulse sequence diagram of LL‐FAIR scheme used for CBF quantification with FAIR labelling followed by five EPI readouts. The initial four flip angles have θ = 35°, with a final readout pulse of flip angle of 90°. The first readout pulse occurs following an initial inversion delay (T I = 600 ms) with subsequent readouts separated by a time interval (T A = 350 ms). Data are collected with vascular crushing (VENC = 7.8 mm/s). the sequence is then repeated with repetition time T R. C, CBVa quantification with FAIR labelling followed by 19 EPI readouts. The first 18 flip angles are θ = 50°, with a final readout pulse of flip angle of 90°. The first readout pulse occurs following an initial inversion delay (T I = 150 ms), with subsequent readouts separated by a time interval (T A = 100 ms). The sequence is then repeated with repetition time T R

CBF is then quantified by iteratively modelling the signal due to multiple readout pulses using a kinetic model that takes into account the duration of the labelled blood arriving in the tissue, the effect of the readout pulse on both arterial blood magnetization and tissue magnetization, and incomplete blood magnetization recovery at short repetition times. This is performed by solving a three‐compartment model, where Compartment 1 contains arterial blood located outside of the imaging volume, Compartment 2 contains arterial blood inside the imaging volume and Compartment 3 contains blood in the capillary bed, which is in exchange with the tissue. For a complete description see Reference 20.

2.2. LL‐FAIR for measurement of CBVa

Alternatively, the LL‐FAIR scheme can be sensitized to CBVa. This is performed by using an LL‐FAIR scheme with a short initial delay (T I = 150 ms) and closely spaced (T A = 100 ms) high flip angle pulses (θ = 50°) for the EPI readout, which are acquired at the shortest achievable echo time (Figure 1C). This has the advantage of providing a large number of EPI readout time points of high SNR to well sample the arterial blood volume inflow curve for quantification of CBVa,8 whilst suppressing any CBF contribution.20 CBVa is quantified by iteratively modelling the signal across the readout pulses in the arterial blood compartment (Compartment 2 described above) using a kinetic model.8

2.3. Gadolinium infusion for measurement of CBVtot

By infusing a contrast agent during an fMRI paradigm whilst acquiring dual‐echo BOLD weighted images for estimation of the transverse relaxation rate (R 2*), the signal can be sensitized to changes in CBVtot. Quantification of this signal is achieved by comparing measurements of R 2* at rest and during activation.13, 14, 15 Under the assumption that stimulus evoked changes in R 2* are constant across multiple trials, additional contributions to R 2* across trials are expected to be solely due to the contrast agent in the blood. In addition, it is assumed that the effect of the contrast agent on the measured signal is predominantly extravascular in origin. Therefore, during rest the measured change in R 2* due to contrast agent can be modelled as

ΔR2*rest=κVtotCAχCA, (1)

where κ is a constant representing physical properties of the experiment, V tot is the resting CBVtot, [CA] is the contrast agent concentration in the blood and χ CA is the molar magnetic susceptibility of the contrast agent.11 During the active condition, the measured change in R 2* due to contrast agent is

ΔR2*act=κVtot+ΔVtotCAχCA, (2)

where ΔV tot is the resultant change in CBVtot. Therefore, the fractional change in CBVtot (δCBVtot) can be estimated by taking the ratio of Equation 1 and Equation 2.

ΔR2*actΔR2*rest=ΔVtotVtot+1=δCBVtot+1. (3)

In an idealized experiment the fMRI stimulus paradigm would be repeated twice, first in the absence of contrast agent and second during a steady state concentration of contrast. However, in practice this is not feasible in human subjects due to dosage limits of GBCAs and their rapid elimination. Therefore, here R 2* measurements are made in the presence of a slowly changing contrast agent concentration provided by an infusion of a GBCA, with ΔR2*rest being extrapolated from periods of rest during activated time points.15

3. METHODS

3.1. Imaging

This study was approved by the University of Nottingham Medical School Ethics Committee. Eight healthy volunteers aged 20 to 31 years (24 ± 3 years, mean ± standard deviation) gave written consent and were scanned as part of this study. A schematic diagram of the experimental protocol is given in Figure 1a. Subjects were cannulated prior to entering the scanner to provide access for the injection of contrast agent and ensure that any motion during the Gd injection in the CBVtot experiment was minimal.

Data were acquired on a Philips Achieva 3 T system (Philips Healthcare, Best, The Netherlands), using a body transmit coil and eight‐channel SENSE (sensitivity encoding) head receive coil. All three haemodynamic parameter measurements were acquired with a common spatial resolution of 3 × 3 × 5 mm3, matrix size of 64 × 64 and SENSE factor 2 and matched bandwidth. Measurements of CBF and CBVa were limited to a single slice acquisition at the time these experiments were performed. Therefore, an initial functional localizer scan was performed in order to select a single axial slice through the visual cortex with the largest region of BOLD activation. This slice prescription was then used throughout the rest of the experiment.

Visual stimulation was provided by red LED goggles flashing at 8 Hz. Lights were on for 19.2 s and off for the remainder of the 60 s cycle. The number of stimulus cycles varied reflecting the differing SNR of each method: eight cycles were collected for CBVa measurements, 12 cycles for CBF (which has a lower contrast to noise ratio) and 14 cycles for CBVtot.

An LL‐FAIR acquisition was used to allow the assessment of both CBF and CBVa measurements accounting for transit time effects. The combination of a Look‐Locker acquisition with a FAIR preparation enables the tagged bolus to be tracked through the macrovascular system and into the tissue sensitizing the signal to CBVa or CBF by using the appropriate combination of sequence parameters. In both cases the thickness of the inversion slab was alternated between 30 mm and 200 mm for label and control conditions, respectively. The sequence parameters for the CBF measurement comprised an initial inversion delay T I = 600 ms, time interval between EPI readouts T A = 350 ms (resulting in an inversion time range of 600 ms to 2000 ms), flip angle θ = 35° and five readout pulses with vascular crushing (bipolar lobe of 5 ms duration per lobe and amplitude of 15 mT, velocity encoding (VENC) = 7.8 mm/s). For the CBVa measurement, the sequence comprised T I = 150 ms, T A = 100 ms (resulting in an inversion time range of 150 ms to 1950 ms), θ = 50°, with 19 readout pulses. In both CBF and CBVa measurements the shortest achievable echo time of 16 ms was used and the final LL‐FAIR pulse had a flip angle of 90° to maximize SNR. The LL‐FAIR scheme was performed with in‐plane pre‐ and post‐saturation pulses to provide signal suppression of the imaging slice, thus reducing any offset signals due to imperfections between the selective and non‐selective RF inversion pulses. The application of a 90° pulse at the end of each T R simplified the modelling, as it ensured that each tag/control acquisition is independent, removing the need for an iterative fit of the data to be performed. The T R between inversion pulses was 2.4 s, resulting in a label/control pair being collected every 4.8 s.

For the measurement of CBVtot, dual‐echo GE‐EPI images were acquired with T E = 13/35 ms, T R = 1.2 s and three slices. Two single doses (0.2 mL kg−1) of Gadoteridol (ProHance, Bracco Imaging, Milan, Italy) were injected, the first bolus at the beginning of the fifth stimulus cycle and the second at the beginning of the sixth cycle. For Cycles 5 and 6, the visual stimulus was not presented and data from these cycles were not used in the estimation of ΔCBVtot. The final 10 cycles of the visual stimulus, after contrast agent injection, were acquired at different contrast agent concentration levels during clearance of the contrast by the kidneys.

3.2. Analysis

For each subject, CBF, CBVa and CBVtot data sets were first realigned within each data set and then across all data sets using SPM5 (5 mm FWHM Gaussian smoothing kernel and second degree B‐spline interpolation).25 Since the CBF and CBVa data were acquired for a single slice, motion correction was restricted to in‐plane motion and rotation. In the case of the CBVtot measurement, the acquisition of three slices provided for the correction of small amounts of through‐slice motion. For the CBF and CBVa data, the images from the final LL‐FAIR readout pulse (90° flip angle and thus highest SNR) of each volume acquisition (T R period) were realigned, and this transformation matrix then applied to the images acquired from the other LL readout pulses within the corresponding T R period. The CBVtot datasets were realigned using the images acquired at the first echo, and this transformation matrix was then applied to the second echo data. Data for each echo time was then down‐sampled to produce a complete time series with a 2.4 s temporal resolution (matching the CBF and CBVa datasets), and only a single slice co‐registered to the CBF and CBVa datasets was retained.

For the CBF and CBVa data, difference images were first computed from the subtraction of consecutive label and control pairs to provide a time series of CBF‐ and CBVa‐weighted images for each LL‐readout pulse. Average CBF‐ and CBVa‐weighted time series during the visual stimulus cycle were then formed by averaging across cycles, accounting for jittering in the data relative to the stimulus paradigm (thus generating a CBF‐weighted and CBVa‐weighted time series of LL readouts for each time point per stimulus cycle). CBVa‐weighted difference images were quantified to estimate arterial transit time and CBVa voxelwise using a two‐parameter fit, as described in Reference 8, over an averaged stimulus cycle. CBF‐weighted difference images were initially analysed using a two‐parameter fit for capillary transit time and CBF.20 However, since the data had lower SNR than the CBVa data, a two‐parameter fit for each time point within the stimulus cycle was found to increase the noise in the measurement of CBF. Therefore, a mean estimate of the transit time at baseline and on activation was computed and used in a one‐parameter model fit to produce a voxelwise estimates of CBF at each time point over an averaged stimulus cycle.

For the CBVtot data, time series of R 2* values were calculated for each voxel using the realigned, down‐sampled, dual echo data. The fractional change in CBVtot (δCBVtot) was calculated by considering the effect of the contrast agent on the R 2* (transverse relaxation rate) changes that occur during the BOLD response, as shown previously by using an infusion to gradually increase the contrast agent concentration.15 However, in this study two bolus injections of contrast agent were used to raise the initial blood contrast agent concentration, which gradually decreased due to washout through the kidneys. In the analysis, four stimulus cycles prior to the contrast agent injections provided a baseline. Stimulus cycles following immediately after the injections were discarded to allow for recirculation of the contrast agent, leaving the final nine cycles for analysis. In all other aspects, this method is the same as in previous reports, and resulted in an estimate of ΔCBVtot over an averaged stimulus cycle.11, 15

Activated regions were generated for each subject using a correlation analysis of the stimulus delivery applied to the quantified CBF maps in order to be maximally sensitive to the site of activation. Each CBF region of interest (ROICBF) was defined based on the CBF statistical map threshold at p < 0.01 (uncorrected). In addition, a supplementary analysis was performed to examine the impact of a different ROI definition based on common activated voxels across the three measures of CBVa, CBF and δCBVtot. Statistical maps from each measure were thresholded at p < 0.01 (uncorrected) and voxels at the intersection retained to form a common ROI (ROICOMMON).

3.3. Estimation of CBF‐CBV coupling

The coupling between CBF and CBV during neuronal activation was calculated assuming a power law relationship between CBF and CBVtot,

CBVtot=ζCBFαtot, (4)

where values of ζ and α tot have previously been measured in rhesus monkeys using a hyper/hypocapnia challenge as 0.80 and 0.38, respectively.5 Given measurements of the fractional change (i.e. the absolute change in CBV divided by absolute baseline CBV) in CBVtot (δCBVtot) and CBF (δCBF) in response to the visual stimulus, which is dimensionless, the CBF‐CBVtot coupling constant α tot (Grubb's constant) can be estimated by rearranging Equation 4:

αtot=lnδCBVtot+1lnδCBF+1. (5)

Under the assumption that the relationship between CBF and CBVa can be described by the power law relationship given in Equation 4, a CBF‐CBVa coupling constant α a can be defined. In this case δCBVa is the fractional change in CBVa, which is also dimensionless.

αa=lnδCBVa+1lnδCBF+1. (6)

Using these equations, Grubb's constant, α tot, and the CBF‐CBVa coupling constant, α a, were estimated on a per subject basis. Values for δCBF, δCBVtot and δCBVa were extracted from the quantified maps of each parameter and averaged over each of the ROIs. The time window for the active on condition was defined as between 9.6 s and 19.2 s from the start of the stimulus cycle, whilst the baseline off condition was defined to be between 40.8 s and 60 s. Estimates of α tot and α a were then computed using Equations 5 and 6, respectively.

In the absence of direct measurements of CBVv, we estimated the fractional change in venous CBV (δCBVv) using a simple model of the vascular compartments. Changes in total blood volume were approximated as a volume‐weighted sum of two compartments: arterial and venous,

δCBVtot=faδCBVa+fvδCBVv, (7)

where f a and f v are the volume fractions assigned to arterial and venous blood volume compartments (f a = CBVa/CBVtot, f v = CBVv/CBVtot), respectively, and here it is assumed that f a + f v = 1. The capillary volume is assumed to be distributed between the arterial and venous compartments. By rearranging Equation 7, δCBVv can be predicted as a function of arterial and venous volume fractions f a and f v:

δCBVv=δCBVtotfaδCBVafv. (8)

4. RESULTS

Figures 2 and 3 show examples of the raw data acquired in this study from a single subject. The former shows CBF‐weighted (Figure 2A) and CBVa‐weighted (Figure 2B) LL‐FAIR difference images as a function of post‐label delay time averaged over all experimental timepoints; note the higher CNR of the CBVa‐weighted data. The latter presents time courses of CBVa‐, CBF‐ and CBVtot‐weighted data averaged over the voxels in the ROICBF (Figure 3). For this, CBF weighting was achieved by averaging across three LL readouts with post‐label delay times of 950, 1300 and 1650 ms. Similarly, CBVa weighting was obtained by averaging across eight LL readouts with post‐label delay times of 350, 450, 550, 650, 750, 850, 950 and 1050 ms. Finally, the CBVtot‐weighted time course was generated using the second echo of the GE‐EPI dataset (T E = 35 ms).

Figure 2.

Figure 2

Example LL‐FAIR difference images from a single subject as a function of post‐label delay time averaged over all experimental time points. A, CBF‐weighted images were acquired using five EPI readouts with the first four flip angles of θ = 35° and a final excitation pulse of θ = 90°. B, CBVa‐weighted images were acquired using 19 EPI readouts with flip angles of θ = 50° and a final excitation pulse of θ = 90°

Figure 3.

Figure 3

Example time courses of the raw signal for each modality from a single subject averaged over the CBF‐based region of interest. A, CBVa‐weighted LL‐FAIR difference data were acquired over eight stimulus cycles. B, CBF‐weighted LL‐FAIR difference data were acquired over 12 stimulus cycles. C, CBVtot‐weighted gradient echo (GE) EPI data were acquired over a period of 16 min. Two single‐dose boluses of a GBCA were injected at the beginning of minutes 4 and 5. The visual stimulus was presented for the remaining cycles

Estimates of the mean transit time for CBF‐weighted (perfusion transit time) and CBVa‐weighted (arterial transit time) data are presented in Table 1. These data were extracted from the CBF‐based ROI of each subject. During activation the perfusion transit time was found to be significantly reduced (p < 0.05, paired two‐tailed t‐test), but the change in the arterial transit time was not significant (p = 0.11).

Table 1.

Data extracted from ROICBF. Experimental measurements of the mean CBF‐weighted (perfusion) and CBVa‐weighted (arterial) transit times. Per subject standard deviations are presented along with the group mean and standard deviation of each parameter weighted by the number of voxels in each subject's ROI

Subject no No of voxels Perfusion transit time Arterial transit time
On Off On Off
1 22 0.73 ± 0.04 0.72 ± 0.10 0.23 ± 0.08 0.24 ± 0.09
2 41 0.56 ± 0.05 0.66 ± 0.08 0.18 ± 0.01 0.21 ± 0.01
3 80 0.44 ± 0.03 0.61 ± 0.05 0.38 ± 0.01 0.54 ± 0.06
4 5 0.55 ± 0.13 0.46 ± 0.13 0.12 ± 0.02 0.16 ± 0.12
5 70 0.58 ± 0.04 0.80 ± 0.17 0.16 ± 0.01 0.13 ± 0.02
6 107 0.64 ± 0.02 0.67 ± 0.04 0.29 ± 0.02 0.24 ± 0.02
7 77 0.46 ± 0.04 0.66 ± 0.04 0.26 ± 0.01 0.38 ± 0.03
8 13 0.78 ± 0.06 0.93 ± 0.08 0.51 ± 0.06 0.63 ± 0.06
Weighted mean & st. dev. 0.56 ± 0.10 0.68 ± 0.08 0.27 ± 0.08 0.31 ± 0.15

Figure 4 displays the time course for the dimensionless fractional change in each haemodynamic measure (δCBVa, δCBF and δCBVtot) per subject (grey lines), and the group mean weighted by the number of voxels in each subject's CBF derived ROI (solid black line) (see Table 1). Table 2 provides the fractional change measured for each haemodynamic parameter for ROICBF, along with the predicted value of δCBVv estimated assuming a value of arterial volume fraction of f a = 0.3 (f v = 0.7) (this choice of value is discussed below). The uncertainty in each parameter was estimated as the standard deviation of the voxels in the ROI for the measured parameters (baseline and changes in CBVa, CBF and CBVtot) and propagated from these values for the calculated parameters (δCBVv, α tot and α a). Measurements of δCBVtot and δCBVa were found to be statistically significantly different from zero across the group (one‐sample t‐test, p < 0.05), with estimates of α tot and α a provided in Table 2 for each subject and group means of 0.16 ± 0.14 and 0.65 ± 0.24, respectively. In contrast, the estimated value of δCBVv was not statistically significantly different from zero (p = 0.33), which would suggest a CBF‐CBVv coupling constant, α v, of close to zero. Quantified baseline estimates of CBF and CBVa from the baseline time window are also presented in Table 2. Baseline CBVa was found to be inversely correlated with δCBVa (correlation coefficient, R = −0.68). Group means and standard deviations in Table 2 are weighted by the number of voxels in each subject's ROI. The number of voxels included in the ROI varied across subjects, probably due to the use of single‐slice techniques, and in some subjects sub‐optimal placement of the slice. It should be noted that, whilst measurements of δCBVtot have the lowest group standard deviation, when coupled with a low mean value of δCBVtot this technique has the highest relative standard deviation. This propagates through to greater uncertainty in the value of α tot compared with α a.

Figure 4.

Figure 4

Haemodynamic changes during visual stimulation extracted from an ROI defined based on changes in CBF in response to the stimulus: Fractional change in arterial CBV (δCBVa) (a), fractional change in CBF (δCBF) (B) and fractional change in total CBV (δCBVtot) (C). time courses are displayed for all subjects (grey lines) and group mean weighted by the number of voxels in each subject's ROI (black solid line). The visual stimulus period is denoted by a solid black bar and averaging windows highlighted for on (pink; 9.6–19.2 s) and off (blue; 40.8–60 s) conditions

Table 2.

Data extracted from ROICBF. Experimental measurements of baseline CBF in mL/100 g/min and arterial CBV (CBVa) in mL/100 g are presented alongside dimensionless steady state fractional changes in CBF (δCBF), CBVa (δCBVa) and CBVtot (δCBVtot), as well as values of δCBVv estimated assuming a value of arterial volume fraction f a = 0.3 (f v = 0.7). Values of the exponents α tot and α a are calculated on a per subject basis. Per subject standard deviations are presented along with the group mean and standard deviation of each parameter weighted by the number of voxels in each subject's ROI

Subject No of voxels CBF δCBF δCBV tot CBV a δCBV a δCBV v α tot α a
1 22 101.7 ± 6.9 0.22 ± 0.16 0 ± 0.03 4.12 ± 0.04 0.06 ± 0.02 −0.03 ± 0.04 −0.02 ± 0.13 0.31 ± 0.20
2 41 66.9 ± 4.9 0.39 ± 0.14 0.06 ± 0.03 4.51 ± 0.03 0.15 ± 0.05 0.02 ± 0.05 0.18 ± 0.10 0.43 ± 0.13
3 80 66.9 ± 2.3 0.37 ± 0.07 0.07 ± 0.02 0.94 ± 0.02 0.26 ± 0.04 −0.02 ± 0.03 0.20 ± 0.06 0.72 ± 0.12
4 5 54.5 ± 4.2 0.63 ± 0.18 0.22 ± 0.04 0.69 ± 0.02 0.77 ± 0.08 −0.02 ± 0.06 0.41 ± 0.11 1.18 ± 0.28
5 70 47.3 ± 11.7 0.49 ± 0.52 −0.01 ± 0.07 1.48 ± 0.19 0.21 ± 0.16 −0.10 ± 0.12 −0.02 ± 0.17 0.47 ± 0.41
6 107 53.3 ± 10.2 0.67 ± 0.28 0.04 ± 0.05 0.79 ± 0.03 0.61 ± 0.07 −0.20 ± 0.08 0.08 ± 0.10 0.94 ± 0.31
7 77 60.1 ± 10.2 0.41 ± 0.09 0.13 ± 0.04 1.76 ± 0.02 0.16 ± 0.03 0.12 ± 0.06 0.37 ± 0.13 0.42 ± 0.07
8 13 73.7 ± 4.4 0.63 ± 0.12 0.19 ± 0.10 0.83 ± 0.04 0.75 ± 0.11 −0.05 ± 0.15 0.36 ± 0.18 1.15 ± 0.17
Weighted mean & st. dev. 60.7 ± 12.3 0.48 ± 0.13 0.06 ± 0.05 1.37 ± 0.75 0.32 ± 0.21 −0.05 ± 0.11 0.16 ± 0.14 0.65 ± 0.24

The results of the supplementary analysis using a common ROI are presented in the Supporting Information. Figure S1 parallels Figure 4, displaying the fractional changes in each of the haemodynamic measures for the common ROI. However, it should be noted that by producing the ROICOMMON as the intersection of changes in CBVa, CBF and CBVtot the number of included voxels is low across all subjects and zero for one subject (Table S1). Despite this, larger changes in all haemodynamic parameters were observed compared with the results from ROICBF, and a significant increase in CBVv was detected (one‐sample t‐test, p < 0.05). This enabled α v to be estimated as 0.29 ± 0.15 across the group, alongside values of 0.45 ± 0.14 for α tot and 0.70 ± 0.29 for α a. These results can be found in Table S2.

Details of how to access the data underpinning the results presented in this study can be found in the appendix.

5. DISCUSSION

A good understanding of the relationship between changes in CBF and CBV is important for interpreting the physiological changes that underlie functional hyperaemia. However, how these changes translate to a measured BOLD response depends on how such changes are distributed across the different vascular compartments. The results of this study will help to improve models of the BOLD response.11, 26 In turn this will enhance the accuracy and reliability of applications that rely on a correct understanding of the BOLD response. For example, it has been shown that the accuracy of the calibrated BOLD method for quantifying stimulus evoked oxygen metabolism changes is critically dependent on accurate knowledge of CBF‐CBVv coupling.26, 27

In this study, measurements of CBF, CBVa and CBVtot were combined to assess the coupling of CBF changes with changes in arterial, venous and total CBV, within two functionally defined ROIs. For the CBF derived ROI, the CBF‐CBVtot coupling constant α tot was estimated to be 0.16 ± 0.14 and the CBF‐CBVa coupling constant α a was estimated to be 0.65 ± 0.24 (mean ± standard deviation). The estimated change in CBVv within this ROI was not statistically significant. Supplementary analysis using a common ROI (ROICOMMON) provided contrasting results, which are discussed later in this section.

5.1. Comparison with the literature

The coupling between CBF and CBVtot has been the target of numerous studies. The power law relationship (Equation 1) was first introduced by Grubb et al, who measured α tot to be 0.38 in anaesthetized rhesus monkeys during steady state hyper/hypocapnic challenges.5 Further PET measurements in humans, using a combination of radiolabelled water (H2 15O) and carbon monoxide (C15O or 11CO), measured α tot to be 0.3 in response to a visual stimulus28 and 0.29 and 0.64 ± 0.26 during a hyper/hypocapnic challenge,29, 30 respectively (errors reported where available). MRI‐based experiments using a perfluorocarbon contrast agent and continuous ASL (CASL) measured a value of α tot of 0.4 in rats.6 However, in all of these cases measurements were made in the steady state. In this study, a relatively short stimulus duration of 19.2 s was used, which is more relevant for human imaging studies but may not be long enough to allow a steady state to be reached, and hence may explain the smaller value of α tot measured (0.16 ± 0.14) for ROICBF. A larger value of α tot was measured (0.45 ± 0.14) for ROICOMMON, albeit for a much smaller active region of tissue.

The literature regarding the coupling of CBF with CBVa is more limited. Perfluorocarbon studies on rats measured the CBVa change due to steady state hypercapnia and the change in CBF using CASL.6 Reviewing their data, we estimate α a = 0.84. A similar rat study performed by Kim et al7 measured changes in CBF and CBVa in response to a 15 s somatosensory stimulus using the MOTIVE (MRI with modulation of tissue and vessel) technique,31 and from these datasets we estimate α a = 1.73. The values for α a obtained in our study (0.65 ± 0.24 and 0.70 ± 0.29) are at the low end of this range, again perhaps suggesting that a steady state was not achieved using a short stimulus. However, further data are required to investigate the effects of stimulus, species and anaesthesia differences.

This experiment did not allow a direct measurement of CBVv changes. In addition, it was not possible to acquire absolute estimates of CBVtot. Therefore, the changes in CBVv could only be investigated based on assumptions regarding the partitioning of blood volume by a two‐compartment model consisting of arterial and venous volume fractions. The arterial volume fraction f a has previously been measured as 0.27,7 0.29,32 and 0.3–0.37,33 using a range of techniques, each of which is expected to include a small fraction of the post‐arterial capillary blood volume, whilst the venous volume fraction f v has been measured as 0.77 using the quantitative BOLD technique.34 This technique is specifically sensitive to blood vessels containing deoxygenated blood. Whilst this largely consists of blood within venous vessels, it is also expected to include deoxygenated blood within the capillaries. Therefore, the arterial and venous compartments defined in this study might more accurately be described as the oxygenated and deoxygenated compartments. Importantly, it is this deoxygenated blood volume that underlies the BOLD response and best reflects the BOLD specific CBF‐CBV coupling. Therefore, based on the literature values above, f a was assumed to take a value of 0.3. Under this assumption, a non‐significant change in CBVv was estimated for ROICBF, whilst a significant change was recorded for ROICOMMON. This would suggest a CBF‐CBVv coupling constant, α v, of around zero for the former and α v = 0.32 ± 0.14 for the latter. These values bracket the limited range of values of CBF‐CBVv coupling constant given in the literature. In rats a value of α v of 0.20 was measured using a steady state hypercapnia stimulus,6 whilst in humans α v was measured as 0.18 for a steady state hyper/hypocapnic stimulus,10 and 0.18/0.31 for low/high intensity visual stimulation.9 However, even in the latter visual stimulus experiments, the stimulus duration was 96 s and therefore significantly longer than that used in our study. In order to examine the effect of short stimuli we can consider recent work investigating the temporal dynamics of CBVv.35 In this work CBVv was shown to be delayed with respect to changes in CBF and CBVa. Given the short duration of our stimulus, it is likely that this would not produce an appreciable increase in CBVv, consistent with the results from ROICBF. Furthermore this is consistent with two photon microscopy measurements that demonstrated a minimal increase in CBVv for a 10 s stimulus, but a larger and delayed response for a 30 s stimulus.36 Given these findings, the results from ROICOMMON appear to overestimate the change in CBVv.

The inconsistency between the two ROIs considered in this study results from the different voxel selection methods. In the case of ROICBF, the use of a CBF localizer provides sensitivity to perfusion and hence to exchange at the capillary bed. CBF ROIs have previously been shown to be more robust than a BOLD‐based localizer.37 In contrast the CBV localizers used in combination with the CBF localizer to define the ROICOMMON are not specific to any particular vessel scale. Therefore, large vessels in the ROI are likely to be accompanied by small changes in CBV, whilst small vessels might see larger changes. Whilst the correlation between baseline CBVa and δCBVa is not statistically significant, this effect likely explains the intersubject variation in the δCBVa time courses (Figures 4 and S1). In addition, it has been observed that changes in CBVv during activation are spatially heterogenous with both increases and decreases.24 Therefore, selecting for only positive changes in CBV has the potential to overestimate the fractional change during activation and may explain why a significant change in CBVv was observed for ROICOMMON.

5.2. Limitations of the current study

In this work, ROIs were selected using the activated region defined by the CBF data. However, the use of such functionally defined ROIs can lead to statistical bias, resulting in an overestimation of changes in CBF.38 Due to the importance of maintaining comfort in human volunteer studies, time within the scanner was limited. Therefore, it was not possible to acquire an additional CBF dataset to provide an independent definition of the ROI.

A pulsed ASL (PASL) preparation was employed in this study so that the same methodologies could be used for the quantification of both CBF and CBVa and the effects of transit time could be measured and accounted for. The use of a pseudocontinuous ASL (PCASL) approach to measure changes in CBF would likely improve the fidelity of such measurements. However, a PCASL preparation cannot be used for CBVa measurements due to SAR limitations. Therefore, in practice using a PASL preparation for both CBF and CBVa measurements is preferable to maintain the same labelling efficiency in both experiments.

Absolute quantification of CBVtot was not possible in this study, so we could not measure ΔCBVv. This might be measured by tracking the first bolus of contrast agent.39 However, the resolution of the data acquired in this study was too coarse to yield an adequate arterial input function. Absolute CBVtot is reported to be in the range of 3–5 mL/100 g, therefore the results of this study would predict an absolute change in CBVtot (ΔCBVtot) between 0.18 and 0.3 mL/100 g.

Predictions of α v were based on a two‐compartment model of the vasculature: arterial and venous. It was therefore assumed that the capillary compartment was distributed between these two compartments. However, it is likely that changes in capillary CBV will have their own characteristic coupling to CBF and may therefore contribute to an under/overestimation of CBV change in the arterial and venous compartments.

Finally, only steady state changes in haemodynamics were studied since the SNR was not sufficient to study dynamic changes. However, it has been shown that a post‐stimulus undershoot in CBF may contribute to the BOLD post‐stimulus undershoot40 and that changes in CBVv are delayed with respect to changes in CBVa.35 These dynamic variations are expected to add to the complexity of the temporal characteristics of the BOLD response. Repeating this work at higher field might allow the study of these dynamic characteristics, greater knowledge of which may enable the dynamics of changes in oxygen metabolism to be investigated using extensions to methods such as calibrated BOLD.1, 2

6. CONCLUSION

In this study, measurements of CBF, CBVa and CBVtot were performed in individual subjects in a single experimental session to assess the coupling of haemodynamic responses. This information is valuable for furthering our understanding of the BOLD response and for enhancing the accuracy and reliability of applications that rely on models of the BOLD response, such as calibrated BOLD.

Supporting information

TABLE S1 Voxel count for ROICOMMON. Number of voxels in activated regions of interest (ROI) for cerebral blood flow (CBF), arterial cerebral blood volume (CBVa), total cerebral blood volume (CBVtot) and the common ROI for individual subjects obtained for z‐score of 2.31. A common ROI was not found for subject 8.

TABLE S2 Data extracted from ROICOMMON. Experimental measurements of baseline cerebral blood flow (CBF) in ml/min/100 g and arterial cerebral blood volume (CBVa) in ml/100 g are presented alongside dimensionless steady state fractional changes in CBF (δCBF), CBVa (δCBVa) and CBVtot (δCBVtot). Values of the exponents αtot and αa are calculated on a per subject basis. Per subject standard deviations are presented for directly measured parameters along with the group mean and standard deviation of each parameter weighted by the number of voxels in each subject's ROI.

FIGURE S1 Haemodynamic changes during visual stimulation extracted from an ROI defined based on voxels that show significant changes in CBF, CBVa and CBVtot: (a) fractional change in arterial cerebral blood volume (δCBVa), (b) fractional change in cerebral blood flow (δCBF) and (c) fractional change in total cerebral blood volume (δCBVtot). Timecourses displayed for all subjects (grey lines) and group mean weighted by the number of voxels in each subject's ROI (black solid line). The visual stimulus period is denoted by a solid black bar and averaging windows highlighted for ON (pink) and OFF (blue) conditions.

ACKNOWLEDGEMENTS

This work was supported by the Medical Research Council [grant number G0901321]. In addition, RW was supported by a Marie Curie Early Stage Researcher Fellowship and NPB was supported by a Sir Peter Mansfield Postdoctoral Fellowship and by funding from the Engineering and Physical Sciences Research Council [grant number EP/K025716/1].

APPENDIX 1.

The data that underpin the results presented in this work can also be accessed via the Zenodo repository (https://doi.org/10.5281/zenodo.1464828).

Wesolowski R, Blockley NP, Driver ID, Francis ST, Gowland PA. Coupling between cerebral blood flow and cerebral blood volume: Contributions of different vascular compartments. NMR in Biomedicine. 2019;32:e4061 10.1002/nbm.4061

REFERENCES

  • 1. Davis TL, Kwong KK, Weisskoff RM, Rosen BR. Calibrated functional MRI: mapping the dynamics of oxidative metabolism. Proc Natl Acad Sci U S A. 1998;95:1834‐1839. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2. Hoge RD, Atkinson J, Gill B, Crelier GR, Marrett S, Pike GB. Investigation of BOLD signal dependence on cerebral blood flow and oxygen consumption: the deoxyhemoglobin dilution model. Magn Reson Med. 1999;42:849‐863. [DOI] [PubMed] [Google Scholar]
  • 3. Buxton RB, Wong EC, Frank LR. Dynamics of blood flow and oxygenation changes during brain activation: the balloon model. Magn Reson Med. 1998;39:855‐864. [DOI] [PubMed] [Google Scholar]
  • 4. Mandeville JB, Marota JJ, Ayata C, et al. Evidence of a cerebrovascular postarteriole windkessel with delayed compliance. J Cereb Blood Flow Metab. 1999;19:679‐689. 10.1097/00004647-199906000-00012 [DOI] [PubMed] [Google Scholar]
  • 5. Grubb RL, Raichle ME, Eichling JO, Ter‐Pogossian MM. The effects of changes in PaCO2 on cerebral blood volume, blood flow, and vascular mean transit time. Stroke. 1974;5:630‐639. [DOI] [PubMed] [Google Scholar]
  • 6. Lee SP, Duong TQ, Yang G, Iadecola C, Kim S‐G. Relative changes of cerebral arterial and venous blood volumes during increased cerebral blood flow: implications for BOLD fMRI. Magn Reson Med. 2001;45:791‐800. [DOI] [PubMed] [Google Scholar]
  • 7. Kim T, Hendrich KS, Masamoto K, Kim S‐G. Arterial versus total blood volume changes during neural activity‐induced cerebral blood flow change: implication for BOLD fMRI. J Cereb Blood Flow Metab. 2007;27:1235‐1247. 10.1038/sj.jcbfm.9600429 [DOI] [PubMed] [Google Scholar]
  • 8. Brookes MJ, Morris PG, Gowland PA, Francis ST. Noninvasive measurement of arterial cerebral blood volume using Look‐Locker EPI and arterial spin labeling. Magn Reson Med. 2007;58:41‐54. 10.1002/mrm.21199 [DOI] [PubMed] [Google Scholar]
  • 9. Chen JJ, Pike GB. BOLD‐specific cerebral blood volume and blood flow changes during neuronal activation in humans. NMR Biomed. 2009;22:1054‐1062. 10.1002/nbm.1411 [DOI] [PubMed] [Google Scholar]
  • 10. Chen JJ, Pike GB. MRI measurement of the BOLD‐specific flow‐volume relationship during hypercapnia and hypocapnia in humans. Neuroimage. 2010;53:383‐391. 10.1016/j.neuroimage.2010.07.003 [DOI] [PubMed] [Google Scholar]
  • 11. Blockley NP, Francis ST, Gowland PA. Perturbation of the BOLD response by a contrast agent and interpretation through a modified balloon model. Neuroimage. 2009;48:84‐93. 10.1016/j.neuroimage.2009.06.038 [DOI] [PubMed] [Google Scholar]
  • 12. Tuunanen PI, Vidyasagar R, Kauppinen RA. Effects of mild hypoxic hypoxia on poststimulus undershoot of blood‐oxygenation‐level‐dependent fMRI signal in the human visual cortex. Magn Reson Imaging. 2006;24:993‐999. 10.1016/j.mri.2006.04.017 [DOI] [PubMed] [Google Scholar]
  • 13. Kennan RP, Scanley BE, Gore JC. Physiologic basis for BOLD MR signal changes due to hypoxia/hyperoxia: separation of blood volume and magnetic susceptibility effects. Magn Reson Med. 1997;37:953‐956. [DOI] [PubMed] [Google Scholar]
  • 14. Scheffler K, Seifritz E, Haselhorst R, Bilecen D. Titration of the BOLD effect: separation and quantitation of blood volume and oxygenation changes in the human cerebral cortex during neuronal activation and ferumoxide infusion. Magn Reson Med. 1999;42:829‐836. [DOI] [PubMed] [Google Scholar]
  • 15. Pears JA, Francis ST, Butterworth SE, Bowtell RW, Gowland PA. Investigating the BOLD effect during infusion of Gd‐DTPA using rapid T 2* mapping. Magn Reson Med. 2003;49:61‐70. 10.1002/mrm.10340 [DOI] [PubMed] [Google Scholar]
  • 16. Blockley NP, Wesolowski R, Francis ST, Gowland PA. Quantification of cerebral blood volume changes in response to a visual stimulus in humans. Proceedings of the 16th Annual Meeting of the International Society for Magnetic Resonance in Medicine 2008. p. 1908.
  • 17. Lu H, Golay X, Pekar JJ, van Zijl PCM. Functional magnetic resonance imaging based on changes in vascular space occupancy. Magn Reson Med. 2003;50:263‐274. 10.1002/mrm.10519 [DOI] [PubMed] [Google Scholar]
  • 18. Hua J, Qin Q, Donahue MJ, Zhou J, Pekar JJ, van Zijl PCM. Inflow‐based vascular‐space‐occupancy (iVASO) MRI. Magn Reson Med. 2011;66:40‐56. 10.1002/mrm.22775 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19. Look DC, Locker DR. Time saving in measurement of NMR and EPR relaxation times. Rev Sci Instrum. 1970;41:250‐251. [Google Scholar]
  • 20. Francis ST, Bowtell R, Gowland PA. Modeling and optimization of Look‐Locker spin labeling for measuring perfusion and transit time changes in activation studies taking into account arterial blood volume. Magn Reson Med. 2008;59:316‐325. 10.1002/mrm.21442 [DOI] [PubMed] [Google Scholar]
  • 21. Günther M, Bock M, Schad LR. Arterial spin labeling in combination with a Look‐Locker sampling strategy: inflow turbo‐sampling EPI‐FAIR (ITS‐FAIR). Magn Reson Med. 2001;46:974‐984. [DOI] [PubMed] [Google Scholar]
  • 22. Petersen ET, Lim T, Golay X. Model‐free arterial spin labeling quantification approach for perfusion MRI. Magn Reson Med. 2006;55:219‐232. 10.1002/mrm.20784 [DOI] [PubMed] [Google Scholar]
  • 23. Stefanovic B, Pike GB. Venous refocusing for volume estimation: VERVE functional magnetic resonance imaging. Magn Reson Med. 2005;53:339‐347. 10.1002/mrm.20352 [DOI] [PubMed] [Google Scholar]
  • 24. Blockley NP, Driver ID, Fisher JA, Francis ST, Gowland PA. Measuring venous blood volume changes during activation using hyperoxia. Neuroimage. 2012;59:3266‐3274. 10.1016/j.neuroimage.2011.11.041 [DOI] [PubMed] [Google Scholar]
  • 25. Friston KJ, Williams S, Howard R, Frackowiak RS, Turner R. Movement‐related effects in fMRI time‐series. Magn Reson Med. 1996;35:346‐355. [DOI] [PubMed] [Google Scholar]
  • 26. Griffeth VEM, Buxton RB. A theoretical framework for estimating cerebral oxygen metabolism changes using the calibrated‐BOLD method: modeling the effects of blood volume distribution, hematocrit, oxygen extraction fraction, and tissue signal properties on the BOLD signal. Neuroimage. 2011;58:198‐212. 10.1016/j.neuroimage.2011.05.077 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27. Blockley NP, Griffeth VEM, Buxton RB. A general analysis of calibrated BOLD methodology for measuring CMRO2 responses: comparison of a new approach with existing methods. Neuroimage. 2012;60:279‐289. 10.1016/j.neuroimage.2011.11.081 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28. Ito H, Takahashi K, Hatazawa J, Kim S‐G, Kanno I. Changes in human regional cerebral blood flow and cerebral blood volume during visual stimulation measured by positron emission tomography. J Cereb Blood Flow Metab. 2001;21:608‐612. 10.1097/00004647-200105000-00015 [DOI] [PubMed] [Google Scholar]
  • 29. Ito H, Kanno I, Ibaraki M, Hatazawa J, Miura S. Changes in human cerebral blood flow and cerebral blood volume during hypercapnia and hypocapnia measured by positron emission tomography. J Cereb Blood Flow Metab. 2003;23:665‐670. 10.1097/01.WCB.0000067721.64998.F5 [DOI] [PubMed] [Google Scholar]
  • 30. Rostrup E, Knudsen GM, Law I, Holm S, Larsson HBW, Paulson OB. The relationship between cerebral blood flow and volume in humans. Neuroimage. 2005;24:1‐11. 10.1016/j.neuroimage.2004.09.043 [DOI] [PubMed] [Google Scholar]
  • 31. Kim T, Kim S‐G. Quantification of cerebral arterial blood volume and cerebral blood flow using MRI with modulation of tissue and vessel (MOTIVE) signals. Magn Reson Med. 2005;54:333‐342. 10.1002/mrm.20550 [DOI] [PubMed] [Google Scholar]
  • 32. Duong TQ, Kim S‐G. In vivo MR measurements of regional arterial and venous blood volume fractions in intact rat brain. Magn Reson Med. 2000;43:393‐402. [DOI] [PubMed] [Google Scholar]
  • 33. Ito H, Kanno I, Iida H, et al. Arterial fraction of cerebral blood volume in humans measured by positron emission tomography. Ann Nucl Med. 2001;15:111‐116. [DOI] [PubMed] [Google Scholar]
  • 34. An H, Lin W. Cerebral venous and arterial blood volumes can be estimated separately in humans using magnetic resonance imaging. Magn Reson Med. 2002;48:583‐588. 10.1002/mrm.10257 [DOI] [PubMed] [Google Scholar]
  • 35. Kim T, Kim S‐G. Temporal dynamics and spatial specificity of arterial and venous blood volume changes during visual stimulation: implication for BOLD quantification. J Cereb Blood Flow Metab. 2011;31:1211‐1222. 10.1038/jcbfm.2010.226 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36. Drew PJ, Shih AY, Kleinfeld D. Fluctuating and sensory‐induced vasodynamics in rodent cortex extend arteriole capacity. Proc Natl Acad Sci U S a. 2011;108:8473‐8478. 10.1073/pnas.1100428108 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37. Leontiev O, Buxton RB. Reproducibility of BOLD, perfusion, and CMRO2 measurements with calibrated‐BOLD fMRI. Neuroimage. 2007;35:175‐184. 10.1016/j.neuroimage.2006.10.044 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38. Kriegeskorte N, Simmons WK, Bellgowan PSF, Baker CI. Circular analysis in systems neuroscience: the dangers of double dipping. Nat Neurosci. 2009;12:535‐540. 10.1038/nn.2303 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39. Rempp KA, Brix G, Wenz F, Becker CR, Gückel F, Lorenz WJ. Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast‐enhanced MR imaging. Radiology. 1994;193:637‐641. [DOI] [PubMed] [Google Scholar]
  • 40. Griffeth VEM, Buxton RB. Evidence for a cerebral blood flow post‐stimulus undershoot contributing to the BOLD undershoot. Proceedings of the 22nd Annual Meeting of the International Society for Magnetic Resonance in Medicine 2014. p. 1017.

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

TABLE S1 Voxel count for ROICOMMON. Number of voxels in activated regions of interest (ROI) for cerebral blood flow (CBF), arterial cerebral blood volume (CBVa), total cerebral blood volume (CBVtot) and the common ROI for individual subjects obtained for z‐score of 2.31. A common ROI was not found for subject 8.

TABLE S2 Data extracted from ROICOMMON. Experimental measurements of baseline cerebral blood flow (CBF) in ml/min/100 g and arterial cerebral blood volume (CBVa) in ml/100 g are presented alongside dimensionless steady state fractional changes in CBF (δCBF), CBVa (δCBVa) and CBVtot (δCBVtot). Values of the exponents αtot and αa are calculated on a per subject basis. Per subject standard deviations are presented for directly measured parameters along with the group mean and standard deviation of each parameter weighted by the number of voxels in each subject's ROI.

FIGURE S1 Haemodynamic changes during visual stimulation extracted from an ROI defined based on voxels that show significant changes in CBF, CBVa and CBVtot: (a) fractional change in arterial cerebral blood volume (δCBVa), (b) fractional change in cerebral blood flow (δCBF) and (c) fractional change in total cerebral blood volume (δCBVtot). Timecourses displayed for all subjects (grey lines) and group mean weighted by the number of voxels in each subject's ROI (black solid line). The visual stimulus period is denoted by a solid black bar and averaging windows highlighted for ON (pink) and OFF (blue) conditions.


Articles from Nmr in Biomedicine are provided here courtesy of Wiley

RESOURCES