Skip to main content
World Journal of Surgical Oncology logoLink to World Journal of Surgical Oncology
. 2019 Apr 30;17:74. doi: 10.1186/s12957-019-1608-6

Malignant ureteral obstruction: experience and comparative analysis of metallic versus ordinary polymer ureteral stents

Yue Chen 1,#, Cheng-yi Liu 1,#, Zhi-hong Zhang 1,, Peng-cheng Xu 2, De-gang Chen 2, Xin-huan Fan 2, Ji-ci Ma 2, Yi-peng Xu 3
PMCID: PMC6492337  PMID: 31039812

Abstract

Background

To study the outcome and experience of using metallic stents in treating patients with malignant ureteral obstruction (MUO).

Methods

Seventy-six patients with MUO were assigned to the metallic stent group (MSG) or the ordinary polymer stent group (OPSG) according to the different materials. The success rate of the operation, duration of operation, patency rate serum creatinine values ,postoperative complications and QOL scores were compared between the two groups.

Results

In the OPSG and MSG, the success rates of the operation were 95.5% and 96.9%, respectively, and the durations of the operation were 20.6 ± 2.2 min and 50.9 ± 10.3 min (P < 0.01), respectively. There was no significant difference between the groups in serum creatinine values at 3 days after the operation (P > 0.05); however, the creatinine values at 3 days after the operation decreased significantly compared with those before the operation (P < 0.01). In the OPSG, there was no significant difference in creatinine values between 3 days and 6 months after operation, while the creatinine values 1 year after operation were increased significantly compared to those at 3 days after the operation (P < 0.05). In the MSG, there was no significant difference among creatinine values at different intervals (P > 0.05). The total rate of post-procedural complication was lower in the MSG than that in the OPSG(P < 0.05). There was no significant difference in the QOL score between the two groups before the operation (P > 0.05); however, the QOL scores at 6 months and 1 year after the operation were higher in the MSG than that in the OPSG(P < 0.05). In the MSG, there was no significant difference in the QOL score between preoperation and 6 months after surgery. Similarly, there was also no difference in the QOL score between 6 months after surgery and 1 year after surgery(P > 0.05). On the contrary, the differences of QOL score in the OPSG group were much significant between disparate time intervals (P < 0.05).

Conclusions

For patients with MUO who require long-term retention of the stent, metallic stents with longer indwelling time are superior to ordinary polymeric stents.

Keywords: Metallic stent, Contrast study, Malignant, Ureteral obstruction

Introduction

Ureteral obstructions secondary to malignant tumour increase each year, mainly due to the following factors. First, primary tumours infiltrate the ureteral wall; second, tumours or metastatic lesions oppress the ureter; third, the swollen lymphonodus wraps the ureter [1]; fourth, ureter distortion and lumen stenosis occurs due to oedema and retroperitoneal fibrosis after radiotherapy; and fifth, the elasticity of the ureter is weakened after radiotherapy, thereby affecting its peristaltic urine delivery function [2]. One or both sides could be involved. Clinical removal of the obstruction and rapid improvement of renal function are the primary principles for treatment. In this context, ordinary ureteral stents have poor therapeutic effects and require replacement within a short time, which could lead to secondary trauma; thus, it is necessary to choose methods that maximize the drainage patency and quality of life for the patient, in order to minimize discomfort during stent placement and replacement [3]. Metallic ureteral stent can make up for the above deficiency. In this study, we compared the advantages of new metallic Resonance® stents (Cook Medical, Bloomington, IN, USA) with that of ordinary polymer stents according to large amounts of data, such as serum creatinine values, postoperative patency, postoperative complications, QOL scores, and the beneficial time from surgery. In addition, we obtained the objective evaluation of patients on the metallic stent with QOL score and summarized the surgical experience of catheterization.

Material and methods

Patient characteristics

Data were retrospectively obtained from the medical records of patients with MUO who were treated during the period of June 2014 to August 2018 at the Second Hospital of Tianjin Medical University, Lu'an Affiliated Hospital of Anhui Medical University, and Zhejiang Cancer Hospital. This retrospective study was approved by the institutional review board in our hospital. Patients were informed of the risks and benefits of participation in the study; each provided written, informed consent before enrolment. Based on the different ureteral stent materials, 76 patients were divided into the metallic stent group (MSG) and the ordinary polymer stent group (OPSG), as shown in Table 1.

Table 1.

Patient characteristics of the two groups

Categories MSG (n = 32) OPSG (n = 44) P value
Gender
 Male 13 18 0.980
 Female 19 26
Age (years) 66 (43~81) 61 (49~78) 0.722
SOPT
 Pelvis
  Cervical cancer 10 14 0.281
  Ovarian cancer 6 9
  Rectal cancer 7 5
  Bladder cancer 3 6
  Prostate cancer 2 2
  PMT 1 0
 Abdomen
  Gastric cancer 1 7
  MRT 2 1
SOUO
 Unilateral 22 29 0.795
 Bilateral 10 15
PC (μmol/L)
 Normal 3 1 0.171
 Abnormal 29 43
Methods
 Ant
  PN 9 0 < 0.001
 Ret
  Ureteroscope 21 33
  Cystoscope 1 9
  Failure 1 2
Anaesthesia
 GA 5 8 0.770
 NO-GA 27 36

In the MSG, which comprised 32 patients, 3 different surgical methods were adopted. One case involved catheterization failure, defined as follows: First, all patients included initially accepted retrograde ureteroscope or cystoscope catheterization. Those who could not receive catheterization accepted the percutaneous nephroscope anterograde catheterization; if that failed, the case was recorded as failed catheterization, and nephrostomy was conducted. Second, retrograde ureteroscope or cystoscope catheterization was successful, but the stent position was not good after re-examination; moreover, renal functional improvement was not ideal. In the OPSG, which comprised 44 patients, there were 2 cases of failed catheterization, followed by nephrostomy. The evaluation criteria for inadequate stent drainage after surgery were as follows: with the exclusion of hypertensive nephropathy, diabetic nephropathy, and other kidney damage factors, the patient’s serum creatinine values increased and hydronephrosis became aggravated, as shown by the urinary colour ultrasound or other imaging examinations. For such patients, the stent should be changed before the expected time; if this fails, a nephrostomy was performed.

Operation methods

For OPSG, ureteroscope and cystoscope catheterization were performed in a manner similar to that of traditional surgical methods. For MSG, the following methods were used:

  1. Ureteroscopy catheterization: In the lithotomy position, the guide wire was passed through the ureter lumen into the kidney pelvis with a ureteroscope, followed by a coaxial introduction of the Resonance® sheath and catheter. The guidewire and catheter were then exchanged for the closed-ended metallic stent through the sheath, with the aid of the catheter as a pusher. The sheath was then finally removed to leave the stent in position.

  2. Percutaneous nephroscope anterograde catheterization: In the prone position, guided by ultrasound, the target calyx was punctured. After establishing percutaneous nephroscope channels, the guide wire was anterogradely placed into the bladder with a ureteroscope. Subsequently, the outer sheath along the guide wire was placed into the bladder, and the metallic stent was then placed along the sheath into the bladder and formed a circle in the kidney pelvis.

  3. Cystoscope ureteral catheterization: In the lithotomy position, local anaesthesia was conducted. The method of catheterization was similar to that of the ureteroscope approach.

Statistical analysis

SPSS 16.0 software (IBM Corp, Armonk, NY, USA) was used to analyse the data. The data were expressed as x¯±s. The Mann-Whitney test, chi-square test, and Cox regression analysis were used. P < 0.05 was considered statistically significant.

Results

Comparison of success rate and duration of operation between the two groups

The success rate and duration of operation for each group are shown in Table 2. For the OPSG, which comprised of 44 patients, a total of 56 stents were indwelled in the first catheterization, and there were 2 failure cases. Regarding the replacement of the stents within the next 1 year, there were 5 failed cases. For the MSG, which comprised of 32 patients, a total of 41 stents were indwelled; there are 31 successful cases (Figs. 1 and 2) as well as 1 failed case. Considering the economic aspects for patients with bilateral hydronephrosis, there were three cases in the MSG where the metallic stent was accepted on the side with better kidney function, whereas ordinary polymeric stent was accepted on the other side. The duration of operation for the MSG was longer than that for the OPSG (P < 0.01), according to statistical analysis.

Table 2.

Success rate and duration of operation of the two groups

Group Cases Successful cases Success rate Duration of operation (min) P value
MSG 32 31 96.9% (31/32) 50.9 ± 10.3
OPSG 44 42 95.5% (42/44) 20.6 ± 2.2 < 0.01

Duration of operation is shown only for cases with successful surgery

Fig. 1.

Fig. 1

Metallic stent on the left (a) and metallic stent on the left with ordinary polymeric stent on the right (b)

Fig. 2.

Fig. 2

Metallic stents can be seen in the bladder on both sides with ureteroscope

Comparison of serum creatinine values before and after operation between the two groups

Serum creatinine values before the operation and 3 days, 6 months, and 1 year after the operation are shown in Table 3. The number of cases was modified due to death, failure of normal follow-up and catheterization, and a lack of sufficient time for statistical analysis, as shown in Table 4. Hydronephrosis of these postoperative patients was improved, as shown in the imaging manifestations; lumbago and pyrexia were reduced significantly or disappeared. There was no significant difference in serum creatinine values between the two groups at 3 days after the operation (P > 0.05); however, the creatinine values at 3 days after the operation decreased significantly compared with those before the operation (P < 0.01). In the OPSG, there was no significant difference in creatinine values between 3 days and 6 months after surgery, while creatinine values at 1 year after surgery were increased compared with those at 3 days after surgery (P < 0.05). In the MSG, there were no significant differences among creatinine values at 3 days, 6 months, and 1 year after the operation (P > 0.05). The average duration of follow-up was 12 months, during which ordinary polymer stents were generally replaced within 1–3 months and metallic stents were replaced within approximately 12 months; the longest retention time was approximately 2 years. In the MSG, outpatient re-examinations showed no fracture, translocation, or dysfunction in the metallic stents. Among all patients who were followed-up, six experienced intermittent haematuria, four experienced repeated urinary tract infections after surgery, and one exhibited stones attached to metallic stents.

Table 3.

Results of serum creatinine (μmol/L) detection of the two groups (x¯±s)

Creatinine before operation 3 days after 6 months after 1 year after
MSG 393.9 ± 93.9 (n = 31) 121.0 ± 19.8 (n = 31) 121.3 ± 22.2 (n = 27) 18.2 ± 22.2 (n = 23)
OPSG 377.5 ± 38.4 (n = 42) 119.3 ± 14.5 (n = 42) 159.0 ± 34.9 (n = 36) 235.9 ± 39.0 (n = 28)

Serum creatinine values are shown only for cases with successful surgery

Table 4.

Reasons for altered numbers of cases at different stages

Group 3 days after 6 months after 1 year after
MSG Death 0 1 4
Failure of normal follow-up 0 1 0
Failure of catheterization 1 / /
Failure of statistical time 0 2 /
Statistical cases 31 27 23
OPSG Death 0 2 3
Failure of normal follow-up 0 3 1
Failure of catheterization 2 1 1
Statistical cases 42 36 28

Comparison of patency rate 1 year after operation between the two groups

In the OPSG, the patency rates at 3 days, 6 months, and 1 year after the operation were 100% (42/42), 83.8% (31/37), and 40.0% (12/30), respectively (Fig. 3). There were a total of five deaths; three of these (one within 6 months and two within 1 year after surgery) exhibited renal impairment before death. In the MSG, the patency rates at 3 days, 6 months, and 1 year after operation were 100% (31/31), 100% (28/28), and 91.7% (22/24), respectively (Fig. 3). Two of these patients exhibited renal impairment within 1 year after the operation, with increased creatinine values and aggravated hydronephrosis as shown by urinary colour ultrasound. One of the cases was considered to be the result of the obstruction of urinary blood clots, since the KUB showed that the metallic stents were in good locations with normal shapes. Therefore, after symptomatic treatment, the renal function gradually improved during follow-up. The other case involved death due to lumen blocking caused by bladder cancer invading the ureter. Four other deaths involved no obvious damage to renal function.

Fig. 3.

Fig. 3

Comparison of the patency rate between the two groups, 1 year after operation

Comparison of post-procedural complication, QOL score, and survival risk between the two groups

The post-procedural complication and QOL score of different stages for each group are shown in Tables 5, 6, and 7. The total rate of post-procedural complication was lower in the MSG than that in the OPSG (P < 0.05). There was no significant difference in QOL score between the two groups before the operation (P > 0.05); however, the QOL scores at 6 months and 1 year after the operation were higher in the MSG than that in the OPSG (P < 0.05). In the MSG, there was no significant difference in the QOL score between preoperation and 6 months after surgery. Similarly, there was also no difference in the QOL score between 6 months after surgery and 1 year after surgery (P > 0.05). On the contrary, the differences of QOL score in the OPSG group were much significant between disparate time intervals (P < 0.05).

Table 5.

Results of post-procedural complications of the two groups

Group ISOB UTI Lumbago APOS Haematuresis COS total P value
MSG (n = 30) 2 2 1 0 6 0 11
OPSG (n = 33) 3 5 1 3 5 4 21 0.032

Post-procedural complications are shown only for cases with normal follow-up and successful surgery

Table 6.

Results of QOL score of the two groups (x¯±s)

QOL Score
Group Before operation 6 months after P value 6 months after 1 year after P value
MSG 29.1 ± 2.5 30.9 ± 2.8 0.325 30.9 ± 2.8 30.7 ± 3.1 0.845
OPSG 28.4 ± 1.5 23.6 ± 1.8 0.002 23.6 ± 1.8 21.3 ± 1.1 0.01

Table 7.

Comparison of QOL score between the two groups

QOL score
Time MSG OPSG P value
Before operation 29.1 ± 2.5 28.4 ± 1.5 0.167
6 months after 30.9 ± 2.8 23.6 ± 1.8 < 0.001
1 year after 30.7 ± 3.1 21.3 ± 1.1 < 0.001

The Cox multivariate analysis of potential survival risk did not yield any endpoints of statistical significance including gender, age at diagnosis, tumour location, site of ureteral obstruction, preoperative creatinine, stent type, and anaesthesia in spite of reduced survival rates with prolonged follow-up (Table 8 and Fig. 4).

Table 8.

Cox multivariate analysis of survival risk of patients with MUO

Variable P value
Gender 0.283
Age 0.064
SOPT (abdomen, pelvis) 0.870
SOUO (bilateral, unilateral) 0.159
PC 0.399
Stent type 0.753
Anaesthesia 0.250

Fig. 4.

Fig. 4

Survival rates decreased with prolonged follow-up

Discussion

Malignant tumours causing ureteral obstruction are mainly from the abdomen, pelvis, and retroperitoneum; these include rectal cancer, colon cancer, gastric cancer, cervical cancer, ovarian cancer, bladder cancer, and prostate cancer. Methods for removing malignant external compressive ureteral obstructions include ureteral stenting and nephrostomy. Since nephrostomy causes inconvenience and trauma, ureteral stenting is often used. Three technical parameters are critical for ideal ureteral stent performance: design, materials, and surface coating [4], and thus, it can be divided into ordinary polymer stent, strengthened polymer stent, metallic stent, coated stent, and drug-eluting stent. Ordinary ureteral stents are made with a mixture of polyethylene and polyurethane [5]; thus, they are limited by their own composition, including poor compression resistance. When used for the treatment of malignant external compressive ureteral obstructions, such stents easily cause inadequate drainage, as well as a short replacement cycle. Therefore, it is difficult to ensure long-term and efficient drainage, and new ideal ureteral stents are needed. The compression resistance of strengthened polymer stent is better than that of ordinary polymer stent; however, it may still lead to poor drainage under higher pressure. The metallic stent may be finally selected as a last resort and has been reported to be safe and effective in the treatment of MUO [613]. Christman et al. evaluated the resistance to radial compression of various stents, Silhouette, Sof-Curl, Tecoflex, Resonance, Polaris Ultra, and Percuflex. The results showed that greater force was needed to compress the Resonance and Silhouette stents compared to others [14].

In this study, we used the Resonance® metallic ureteral stent, which is a hollow, spiral-shaped, full-length metal stent with the same shape as the double J catheter. It has the following advantages: first, it is made of nickel-cobalt-chromium-molybdenum alloy, which has high biocompatibility and less capsid, such that it is not prejudiced against MRI examination; second, its dense, hollow, spiral structure can inhibit endogenous tissue growth and can provide double drainage from the spiral outer surface and the lumen; third, its radial compressive resistance is > 68 kg, which is much higher than that of traditional stents (4~11 kg) and other metal stents [15]; fourth, it is soft, with a certain elasticity and less abnormal sensation; fifth, its indwelling time is more than 12 months, thus reducing the pain caused by stent replacement; and sixth, the stent and its accessories can clearly be shown through X-ray and B-ultrasound, facilitating monitoring and re-examination. Considering the high-pressure resistance, good drainage effect, longer replacement period, and advantages of ensuring the patient quality of life, the Resonance® metallic ureteral stent has become an ideal stent for removing MUO; for patients with shorter life expectancy, it can even be a permanent stent for treatment.

The patency rate of metallic stents for the treatment of MUO lies between 37% and 100% [1621], and the success rate of the operation is 96% [22], according to literature reports. In our study, the success rate of metallic stent catheterization was 96.9%. In the two groups, hydronephrosis improved, as shown by imaging; moreover, there was no significant difference in serum creatinine values between the groups (P > 0.05), while creatinine values at 3 days after the operation in each group were significantly lower than those before the operation (P < 0.01). This finding indicated that catheterization of either metallic stents or ordinary polymeric stents could enable effective hydronephrosis drainage and improve short-term renal function. As the statistical analysis shows, there was no significant difference in creatinine values among 3 days, 6 months, and 1 year after operation in the MSG (P > 0.05). Furthermore, in the OPSG, there was no significant difference in creatinine values between 3 days and 6 months after operation (P > 0.05); however, the creatinine values at 1 year after operation were significantly higher than those at 3 days after operation (P < 0.05). The patency rate decreased to 40.0%, which was in striking contrast to the 91.7% observed in the MSG; this finding indicated that over 6 months, both the metallic stent and ordinary polymeric stent maintain a high drainage patency rate. However, 1 year later, even ordinary polymeric stents with regular replacement could not assure a higher patency rate, and the replacement success rate was gradually decreased. The advantages of metallic stents are notable. Although the duration of the operation of metallic stent catheterization was longer than that of the ordinary polymeric stent (P < 0.01), this difference may be related to the surgeon’s proficiency. Overall, therefore, metallic stents are preferred for patients with malignant external compressing ureteral obstructions.

Thus far, reports of surgical experience sharing regarding metallic stent catheterization are not too much. To our knowledge, the success rate of catheterization has no relation to the type of stent but is related to the patient’s objective condition. The main reasons for failed catheterization are as follows: first, bladder shape is altered and the ureteral orifice moves with pelvic tumour compression, or after uterine and rectal tumour surgery, thereby causing an undiscoverable ureteral orifice (Figs. 5 and 6); second, the tumour infiltrates the ureteral orifice, which leads to an undiscoverable ureteral orifice or inability of the guide wire to enter the ureteral lumen (Fig. 7); third, patients exhibit vesicovaginal fistula, in which the bladder does not fill; and fourth, ureteral lumen distortion or metastatic lesions (e.g. lymphonodus) can exhibit pressure on the ureteral lumen. Our experiences suggest the following approach: initially, each patient should accept CTU, magnetic resonance hydrography, or urinary contrast, in order to assess ureteral status before surgery. In addition, stenotic segments often arise from the lower ureter. In ureterostenosis, an extension can be made during the operation with a ureteral catheter or renal sheath dilator, followed by catheterization. This often leads to success. With a ureteroscope horizontally rotated and extruded with a specific vertical strength, the stenotic segments could also be broken through and the ureteral injury or fracture could generally be avoided. Finally, when the catheterization fails for the reasons above, there are various flexible methods for management, such as percutaneous nephroscope anterograde catheterization for situations involving an undiscoverable ureteral orifice, or a preset micro-nephrostomy tube (F6 or F7) with methylene blue injection during the operation to aid in locating the ureteral orifice via ureteroscope. In the clinic, we usually choose ureteroscope or cystoscope catheterization, which may cause relatively small trauma; most of these surgeries are successful. In addition, the method of percutaneous nephroscope anterograde catheterization has been conducted entirely due to undiscoverable ureteral orifice or failure to enter the ureter via ureteroscope.

Fig. 5.

Fig. 5

Altered bladder shape after radical resection of rectal carcinoma, shown by urography

Fig. 6.

Fig. 6

Altered bladder shape after radical resection of rectal carcinoma, shown by computed tomography

Fig. 7.

Fig. 7

Tumour invading the bladder neck and the right wall

Those who have internal metallic stents need regular follow-up and should replace the stents within 1 year to avoid stone formation. Some patients who have rapid tumour progression or infiltrated ureteral lumen, or who are susceptible to stones should replace the stents within 6 months [17]. During our follow-up, the average indwelling time of the ordinary polymer stent was only 3 months, while the indwelling time of the metallic stent was approximately 12 months, and even nearly 2 years. As the statistical analysis has shown, the total rate of post-procedural complication was lower in the MSG than that in the OPSG(P < 0.05). The outpatient re-examinations showed no fracture, translocation, or dysfunction in the metallic stents. There was no significant difference in the QOL score between the two groups before the operation(P > 0.05). However, the QOL scores at 6 months and 1 year after the operation were higher in the MSG than that in the OPSG (P < 0.05). In the MSG, there was no significant difference in the QOL score between preoperation and 6 months after surgery. Similarly, there was also no difference in the QOL score between 6 months after surgery and 1 year after surgery(P > 0.05). On the contrary, the differences of QOL score in the OPSG group were much significant between disparate time intervals (P < 0.05). We think there were several reasons for the lower QOL score of most patients with ordinary polymer stents. Firstly, because the QOL score was greatly influenced by the progress of primary tumour and individual psychological factors, frequent replacement of the stent might result in worry and fear. Secondly, nephrostomy leads to a low quality of life for those patients with failed catheterization due to inconvenience and trauma. Thirdly, family conflicts may occur due to repeated hospitalizations. Lastly, postoperative complications were the important factors. The Cox multivariate analysis of potential survival risk did not yield any endpoints of statistical significance including gender, age at diagnosis, tumour location, site of ureteral obstruction, preoperative creatinine, stent type, and anaesthesia in spite of reduced survival rates with prolonged follow-up (Fig. 4). Additionally, we further analyzed the reasons why stent type did not affect the survival of patients. We do not deny the fact that metallic stent can indeed reduce post-procedural complication, prolong the period of stent replacement, and improve the quality of life. Nevertheless, nephrostomy can still maintain good renal function irrespective of the inferior quality of life for those patients with ordinary polymer stent and even failed catheterization in the replacement process. What really affected survival was the degree for the progression of primary tumour. The metallic ureteral stent has limitations; for example, it has high costs for a single operation. However, some studies have shown that the patients experience reduced financial burden because of the reduced frequency of replacement, despite the high single-operation costs [2326]. Given the cost-effectiveness of metallic stents, they are more suitable for long-term treatment.

Conclusions

We conclude that the Resonance® metallic stent is safe and effective for treating MUO. For patients who require long-term stent retention, metallic ureteral stents with good drainage effect, longer indwelling time, and lower cost are superior to ordinary polymeric stents.

Acknowledgements

The authors would like to acknowledge Hongbo Yu for their kind help with data collection, Professor Enci Xu for her kind comments on paper writing, all the nurses in our center for their services, and patients involved in this study.

Funding

None.

Availability of data and materials

The analyzed data sets generated during the study are available from the corresponding author upon reasonable request.

Abbreviations

Ant

Anterograde

APOS

Abnormal position of stent

COS

Capsid of stent

GA

General anaesthesia

ISOB

Irritation sign of bladder

MRT

Malignant retroperitoneal tumour

MSG

Metallic stent group

MUO

Malignant ureteral obstruction

OPSG

Ordinary polymer stent group

PC

Preoperative creatinine

PMT

Pelvic malignancy tumour

PN

Percutaneous nephroscope

Ret

Retrograde

SOPT

Site of primary tumour

SOUO

Site of ureteral obstruction

UTI

Urinary tract infection

Authors’ contributions

CYL and ZHZ drafted the manuscript. YC, PCX, and DGC collected the data. YC, XHF, and JCM analyzed the data. YPX revised and proofread the manuscript. All authors read and approved the final manuscript.

Ethics approval and consent to participate

The study was approved by the ethics committees of The Second Hospital of Tianjin Medical University and LU’AN Affiliated Hospital of Anhui Medical University. Informed consent was obtained from all individual participants included in the study.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Contributor Information

Yue Chen, Phone: +86-022-88329692, Email: chenyue831106@163.com.

Cheng-yi Liu, Phone: +86+13395646198, Email: Liuchengyi2019@163.com.

Zhi-hong Zhang, Phone: +86+13920695369, Email: 1191960781@qq.com.

Peng-cheng Xu, Phone: +86+13966248910, Email: xupc2016@126.com.

De-gang Chen, Phone: +86+13865758643, Email: chengdegang.908@163.com.

Xin-huan Fan, Phone: +86+13865796960, Email: fanxinhuan2001@yahoo.com.cn.

Ji-ci Ma, Phone: +86+13637254446, Email: majici@sina.com.

Yi-peng Xu, Phone: +86+15868413863, Email: 420993645@qq.com.

References

  • 1.Ishioka J, Kageyama Y, Inoue M, Higashi Y, Kihara K. Prognostic model for predicting survival after palliative urinary diversion for ureteral obstruction: analysis of 140 cases. J Urol. 2008;180:618–621. doi: 10.1016/j.juro.2008.04.011. [DOI] [PubMed] [Google Scholar]
  • 2.Chitale SV, Scott-Barrett S, Ho ETS, Burgess NA. The management of ureteric obstruction secondary to malignant pelvic disease. Clin Radiol. 2002;57(12):1118–1121. doi: 10.1053/crad.2002.1114. [DOI] [PubMed] [Google Scholar]
  • 3.Aravantinos E, Anagnostou T, Karatzas AD, Papakonstantinou W, Samarinas M, Melekos MD. Percutaneous nephrostomy in patients with tumors of advanced stage: treatment dilemmas and impact on clinical course and quality of life. J Endourol. 2007;21(11):1297. doi: 10.1089/end.2006.0104. [DOI] [PubMed] [Google Scholar]
  • 4.Mosayyebi A, Manes C, Carugo D, Somani BK. Advances in ureteral stent design and materials. Curr Urol Rep. 2018;19:35. doi: 10.1007/s11934-018-0779-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Gorman SP, Jones DS, Bonner MC, Akay M, Keane PF. Mechanical performance of polyurethane ureteral stents in vitro and ex vivo. Biomaterials. 1997;18(20):1379–1383. doi: 10.1016/S0142-9612(97)00070-7. [DOI] [PubMed] [Google Scholar]
  • 6.Woo KJ, Bumsik H, Hoon SJ, et al. A prospective randomized comparison of a covered metallic ureteral stent and a double-J stent for malignant ureteral obstruction. Korean J Radiol. 2018;19(4):606–612. doi: 10.3348/kjr.2018.19.4.606. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Chow PM, Chiang IN, Chen CY, et al. Malignant ureteral obstruction: functional duration of metallic versus polymeric ureteral stents. PloS One. 2015;10(8):e0135566. doi: 10.1371/journal.pone.0135566. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Kadlec AO, Ellimoottil CS, Greco KA, Turk TM. Five-year experience with metallic stents for chronic ureteral obstruction. J Urol. 2013;190(3):937–941. doi: 10.1016/j.juro.2013.02.070. [DOI] [PubMed] [Google Scholar]
  • 9.Goldsmith ZG, Wang AJ, Bañez LL, Lipkin ME, Ferrandino MN, Preminger GM, Inman BA. Outcomes of metallic stents for malignant ureteral obstruction. J Urol. 2012;188(3):851–855. doi: 10.1016/j.juro.2012.04.113. [DOI] [PubMed] [Google Scholar]
  • 10.Kim M, Hong B, Park HK. Long-term outcomes of double-layered polytetrafluoroethylene membrane-covered self-expandable segmental metallic stents (Uventa) in patients with chronic ureteral obstructions: is it really safe? J Endourol. 2016;30:1339–1346. doi: 10.1089/end.2016.0462. [DOI] [PubMed] [Google Scholar]
  • 11.Kim KS, Choi S, Choi YS, Bae WJ, Hong SH, Lee JY, et al. Comparison of efficacy and safety between a segmental thermo-expandable metal alloy spiral stent (Memokath 051) and a self-expandable covered metallic stent (UVENTA) in the management of ureteral obstructions. J Laparoendosc Adv Surg Tech A. 2014;24:550–555. doi: 10.1089/lap.2014.0056. [DOI] [PubMed] [Google Scholar]
  • 12.Chung HH, Kim MD, Won JY, Won JH, Cho SB, Seo TS, et al. Multicenter experience of the newly designed covered metallic ureteral stent for malignant ureteral occlusion: comparison with double J stent insertion. Cardiovasc Intervent Radiol. 2014;37:463–470. doi: 10.1007/s00270-013-0675-2. [DOI] [PubMed] [Google Scholar]
  • 13.Kim KH, Cho KS, Ham WS, Hong SJ, Han KS. Early application of permanent metallic mesh stent in substitution for temporary polymeric ureteral stent reduces unnecessary ureteral procedures in patients with malignant ureteral obstruction. Urology. 2015;86:459–464. doi: 10.1016/j.urology.2015.06.021. [DOI] [PubMed] [Google Scholar]
  • 14.Christman MS, L’esperance JO, Choe CH, et al. Analysis of ureteral stent compression force and its role in malignant obstruction [J] The Journal of Urology. 2009;181(1):392–396. doi: 10.1016/j.juro.2008.08.125. [DOI] [PubMed] [Google Scholar]
  • 15.Pedro Renato N., Hendlin Kari, Kriedberg Carly, Monga Manoj. Wire-Based Ureteral Stents: Impact on Tensile Strength and Compression. Urology. 2007;70(6):1057–1059. doi: 10.1016/j.urology.2007.08.007. [DOI] [PubMed] [Google Scholar]
  • 16.Nagele U, Kuczyk MA, Horstmann M, Hennenlotter J, Sievert KD, Schilling D, Walcher U, Stenzl A, Anastasiadis AG. Initial clinical experience with full-length metal ureteral stents for obstructive ureteral stenosis. World J Urol. 2008;26(3):257. doi: 10.1007/s00345-008-0245-4. [DOI] [PubMed] [Google Scholar]
  • 17.Potretzke AM, Chang H, Kryger JV. Technique for Resonance® stent exchange in patients with extrinsic obstruction: description of a novel approach and literature review. J Pediatr Urol. 2012;8:557–559. doi: 10.1016/j.jpurol.2012.01.018. [DOI] [PubMed] [Google Scholar]
  • 18.Borin JF, Melamud O, Clayman RV. Initial experience with full-length metal stent to relieve malignant ureteral obstruction. J Endourol. 2006;20:300–304. doi: 10.1089/end.2006.20.300. [DOI] [PubMed] [Google Scholar]
  • 19.Modi AP, Ritch CR, Arend D, Walsh RM, Ordonez M, Landman J, Gupta M, Knudsen BE. Multicenter experience with metallic ureteral stents for malignant and chronic benign ureteral obstruction. J Endourol. 2010;24:1189–1193. doi: 10.1089/end.2010.0121. [DOI] [PubMed] [Google Scholar]
  • 20.Asakawa J, Iguchi T, Tamada S, Ninomiya N, Kato M, Yamasaki T, Nakatani T. Outcomes of indwelling metallic stents for malignant extrinsic ureteral obstruction. Int J Urol. 2018;25(3):258–262. doi: 10.1111/iju.13500. [DOI] [PubMed] [Google Scholar]
  • 21.Abbasi A, Wyre HW, Ogan K. Use of full-length metallic stents in malignant ureteral obstruction. J Endourol. 2013;27:640–645. doi: 10.1089/end.2012.0448. [DOI] [PubMed] [Google Scholar]
  • 22.Patel C, Loughran D, Jones R, Abdulmajed M, Shergill I. The resonance® metallic ureteric stent in the treatment of chronic ureteric obstruction: a safety and efficacy analysis from a contemporary clinical series. BMC Urol. 2017;17(1):16. doi: 10.1186/s12894-017-0204-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Lópezhuertas HL, Polcari AJ, Acostamiranda A, Turk TM. Metallic ureteral stents: a cost-effective method of managing benign upper tract obstruction. J Endourol. 2010;24(3):483–485. doi: 10.1089/end.2009.0192. [DOI] [PubMed] [Google Scholar]
  • 24.Taylor ER, Benson AD, Schwartz BF. Cost analysis of metallic ureteral stents with 12 months of follow-up. J Endourol. 2012;26(7):917–921. doi: 10.1089/end.2011.0481. [DOI] [PubMed] [Google Scholar]
  • 25.Frederick L, Ellimoottil C, Kadlec A, Shah A, Turk T, Schwartz BF. Cost analysis of metallic stents for chronic ureteral obstruction: a multicenter study. Urol Pract. 2016;4:1. doi: 10.1016/j.urpr.2016.03.008. [DOI] [PubMed] [Google Scholar]
  • 26.Baumgarten AS, Hakky TS, Carrion RE, Lockhart JL, Spiess PE. A single-institution experience with metallic ureteral stents: a cost-effective method of managing deficiencies in ureteral drainage. Int Braz J Urol. 2014;40(2):225–231. doi: 10.1590/S1677-5538.IBJU.2014.02.13. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The analyzed data sets generated during the study are available from the corresponding author upon reasonable request.


Articles from World Journal of Surgical Oncology are provided here courtesy of BMC

RESOURCES