To the Editor,
Recently we read with great interest the article by Fard and colleagues,1 which conducted a systematic review and meta-analysis to compare the overall intraocular pressure (IOP)-lowering effect of iStent or CyPass as isolated procedures or in combination with cataract extraction. The authors concluded that “both iStent and CyPass either in combination with cataract extraction or as isolated procedures effectively decrease IOP. This effect is greatest with isolated implantation of CyPass followed by multiple iStents and then single iStent implantation and lasts up to 2 years”. We would like to point out why results from this analysis should be interpreted with caution.
First, the authors stated that patients were stratified by baseline IOP ⩾ 21 mmHg and < 21 mmHg, however it was not specified if the values were washout or medicated IOP and what was included is a mix of these values. For example, the preoperative baseline IOP after the washout period was included for the Fernandez-Barrientos et al.2 and Hoeh et al.3 studies, while the medicated screening IOP values were computed for the Craven et al.4 and Fea et al.5 studies. IOP reductions based on preoperative washout or unmedicated IOP may report larger reductions in IOP from the same studies compared with preoperative medicated IOP as its baseline measurement. It is acknowledged in the World Glaucoma Association guidelines on design and reporting of glaucoma surgical trials that “in order to quantify the IOP reduction after surgery, a consistent definition of the baseline, or reference IOP is essential. This may be recorded as IOP before medication was started, the IOP after washout of medication or the IOP of the patient’s full medical regimen just before surgery”.6 For data included in this type of meta-analysis, baseline IOP values should be consistent in whether they include washout or medicated IOP values to more appropriately compare IOP-lowering effect.
Second, the design of studies included in a systematic review can have a substantial impact on the estimation of the treatment effect and therefore should be considered within that context when considering the trial design of each individual study for inclusion in a meta-analysis. Changes in IOP are generally a function of medication use. For example, in the Katz study, postoperative glaucoma medication was started if IOP exceeded a prespecified target of 18 mmHg or in the case of optic nerve or VF changes.7 Whereas, in the Garcia-Feijoo study, reintroduction of IOP-lowering medication was left to the discretion of the investigator and dependent on the target IOP of each subject.8 Differences in study designs such as these will lead to differences in IOP and medication-reducing effects, which are an artifact of design rather than entirely due to the treatment effect of the intervention.
Third, while we agree with McAuley and colleagues, that meta-analysts should attempt to identify, retrieve, and include all reports, grey and published, that meet predefined inclusion criteria,9 we take issue with basing the conclusion that CyPass has the greatest IOP-lowering effect among the comparators on Flowers,10 Garcia-Feijoo,8 Guguchkova, and Grabner11. In Figure 5 (a) it is reported that the IOP-lowering effect includes a weight of 88.2% from Flowers and colleagues. As the Flowers source is an abstract, limited information is available and it is not reported if this is computed with washout or medicated baseline IOP. Also, the corresponding medication reduction is not reported. Without this important information, interpretation of the meta-analysis is challenging. In addition to this, the Guguchkova study is not included in the references so the study design describing how medications were reintroduced could not be verified.
Finally, the systematic review included only references that were published up to July 2016. Since then several studies have been reported including large randomized controlled trials such as COMPASS (n = 374),11 (n = 54),12 and the iStent inject pivotal study (n = 380).13 Although, it is recognized that systematic literature reviews require a cut-off date, these recent large studies would heavily influence results. Results of this meta-analysis should be considered with the substantial amount of data now available and their contribution to the results presented by Fard and colleagues.1
We therefore urge interpretation of these results with caution. To better estimate the effect of these treatments the considerations described here should be taken into account.
Footnotes
Funding: The author(s) received no financial support for the research, authorship, and/or publication of this article.
Conflict of interest statement: The author(s) declared following potential conflicts of interest with respect to the research, authorship, and/or publication of this article: L. Jay Katz is the Chief Medical Officer of Glaukos Corp. Heather Falvey is an employee of Glaukos Corp.
ORCID iD: Heather Falvey
https://orcid.org/0000-0003-4498-215X
Contributor Information
L. Jay Katz, Glaukos Corp, 229 Avenida Fabricante, San Clemente, CA 92672, USA.
Heather Falvey, Glaukos Corp, 229 Avenida Fabricante, San Clemente, CA 92672, USA hfalvey@glaukos.com.
References
- 1. Fard Patel SP, Pourafkari L, et al. Comparing iStent versus CyPass with or without phacoemulsification in patients with glaucoma: a meta-analysis. Ther Adv Chronic Dis 2019; 10: 1–16. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2. Fernandez-Barrientos Y, Garcia-Feijoo J, Martinez-de-la-Casa JM, et al. Fluorophotometric study of the effect of the glaukos trabecular microbypass stent on aqueous humor dynamics. Invest Ophthalmol Vis Sci 2010; 51: 3327–3332. [DOI] [PubMed] [Google Scholar]
- 3. Hoeh H, Vold SD, Ahmed IK, et al. Initial clinical experience with the cypass microstent: safety and surgical outcomes of a novel supraciliary microstent. J Glaucoma 2016; 25: 106–112. [DOI] [PubMed] [Google Scholar]
- 4. Craven ER, Katz LJ, Wells JM, et al. Cataract surgery with trabecular micro-bypass stent implantation in patients with mild to moderate open-angle glaucoma and cataract: two-year follow-up. J Cataract Refract Surg 2012; 38: 1339–1345. [DOI] [PubMed] [Google Scholar]
- 5. Fea AM, Belda JI, Rekas M, et al. Prospective unmasked randomized evaluation of the iStent inject® versus two ocular hypotensive agents in patients with primary open-angle glaucoma. Clin Ophthalmol 2014; 8: 875–882. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6. Shaaraway, et al. World glaucoma associated guideline on design and reporting of glaucoma surgical trials. Amsterdam, The Netherlands: Kugler Publications, 2009. [Google Scholar]
- 7. Katz LJ, Erb C, Carceller GA, et al. Prospective, randomized study of one, two, or three trabecular bypass stents in open-angle glaucoma subjects on topical hypotensive medication. Clin Ophthalmol 2015; 9: 2313–2320. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8. Garcia-Feijoo J, Rau M, Grisanti S, et al. Supraciliary micro-stent implantation for open angle glaucoma failing topical therapy: 1-year results of a multicenter study. Am J Ophthalmol 2015; 159: 1075–1081 e1. [DOI] [PubMed] [Google Scholar]
- 9. McAuley, et al. Does inclusion of grey literature influence estimates of intervention effectiveness reported in meta-analyses? Lancet 2000; 356(9237): P1228–1231. [DOI] [PubMed] [Google Scholar]
- 10. Flowers BRM, Nardi M, Flynn W, et al. (ed) Safety and efficacy of stand-alone CyPass Micro-Stent implantation in patients refractive to topical glaucoma therapy: 1 year results. San Fransisco: American Society of Cataract and Refractive Surgery, 2013. [Google Scholar]
- 11. Grabner GRH. (ed) Two-year results of supraciliary micro-stent implantation in patients refractory to topical glaucoma therapy. San Diego: American Society of Cataract and Refractive Surgery, 2015. [Google Scholar]
- 12. Vold S, Ahmed II, Craven ER, et al. Two-year COMPASS trial results: supraciliary microstenting with phacoemulsification in patients with open-angle glaucoma and cataracts. Ophthalmology 2016; 123: 2103–2112. [DOI] [PubMed] [Google Scholar]
- 13. Vold SD, Voskanyan L, Tetz M, et al. Newly diagnosed primary open-angle glaucoma randomized to 2 trabecular bypass stents or prostaglandin: outcomes through 36 months. Ophthalmol Ther 2016; 5: 161–172. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14. Samuelson TW, Sarkisian SR, Jr., Lubeck, et al. , for the iStent inject Study Group, Prospective, Randomized, Controlled Pivotal Trial of iStent inject Trabecular Micro-Bypass in Primary Open-Angle Glaucoma and Cataract: Two-Year Results, Ophthalmology 2019. DOI: 10.1016/j.ophtha.2019.03.006. [DOI] [PubMed] [Google Scholar]