Abstract
Low-cost, high-throughput and nondestructive metrology of truly three-dimensional (3-D) targets for process control/monitoring is a critically needed enabling technology for high-volume manufacturing (HVM) of nano/micro technologies in multi-disciplinary areas. In particular, a survey of the typically used metrology tools indicates the lack of a tool that truly satisfies the HVM metrology needs of 3-D targets, such as high aspect ratio (HAR) targets. Using HAR targets here we demonstrate that through-focus scanning optical microscopy (TSOM) is a strong contender to fill the gap for 3-D shape metrology. Differential TSOM (D-TSOM) images are extremely sensitive to small and/or dissimilar types of 3-D shape variations. Based on this here we propose a TSOM method that involves creating a database of cross-sectional profiles of the HAR targets along with their respective D-TSOM signals. Using the database, we present a simple-to-use, low-cost, high-throughput and nondestructive process-monitoring method suitable for HVM of truly 3-D targets, which also does not require optical simulations, making its use straightforward and automatable. Even though HAR targets are used for this demonstration, the similar process can be applied to any truly 3-D targets with dimensions ranging from micro-scale to nano-scale. The TSOM method couples the advantage of analyzing truly isolated targets with the ability to simultaneously analyze many targets present in the large field-of-view of a conventional optical microscope.
Keywords: TSOM, nondestructive process control, three-dimensional metrology, through-focus scanning optical microscopy, nanometrology, nanomanufacturing, high-throughput semiconductor metrology
1. INTRODUCTION
With the increase in the use of three-dimensional (3-D) structures in nano/micro technologies, high-throughput and economical 3-D shape metrology and process monitoring of nanoscale to microscale objects is critically necessary [1–10]. This is technically challenging [4, 5, 7, 11–14], especially for high aspect ratio (HAR) targets, including through-silicon vias (TSVs) [13–18]. TSVs are a key component to enable 3-D stacked integrated circuits (3DS-IC), which themselves are key to extended scaling of integrated circuits and enabling heterogeneous integration [15]. Hence it is crucial to find suitable metrology solutions for truly 3-D targets such as HAR targets.
Several metrology tools are currently available or have been proposed [9, 10, 19–42], for 3-D shape measurements. Popular industrial metrology tools currently used are electron based tools (e.g., scanning electron microscope (SEM)), probe based tools (e.g., atomic force microscope (AFM)), and optics-based tools (e.g., scatterometers). The National Institute of Standards and Technology (NIST) pioneered the x-ray tool referred to as critical dimension small angle x-ray scattering (CD-SAXS) [31] that has attracted much attention from the semiconductor industry. Combination of the results of more than one measurement technique, referred to as either hybrid or holistic metrology, initially pioneered at NIST further improved nanometer-scale dimensional measurements [36, 43].
To be used in high volume manufacturing, a metrology tool must - in addition to providing statistically significant results [12] - be fast (high-throughput), low-cost, inline capable, automated, robust, easy to use, non-contact and non-destructive. The requirements for satisfactory measurement sensitivity and resolution have been identified in the International Technology Roadmap for Semiconductors (ITRS) [44] and International Roadmap for Devices and Systems (IRDS) 2017 Edition: Metrology [45]. All currently available tools have certain advantages and disadvantages. It is difficult to find a metrology tool that satisfies all the above-mentioned requirements, especially for metrology of 3-D/HAR targets.
It is very difficult to use top-down SEM imaging for 3-D shape analysis of HAR targets at high-throughput with sufficient measurement resolution. Probe-based tools, such as AFM, have limitations in reaching the bottom of HAR targets due to probe length and width constraints and generally do not meet high-throughput requirements. CDSAX tools currently are too expensive to be industrially relevant for high-volume manufacturing (HVM). Among nondestructive metrology tools traditionally used in nano/micro technologies, optical tools are usually better suited for inline metrology applications. Optical tools, such as spectral reflectometry [35] and interferometry [16] are available for high-throughput depth measurement of HAR targets but are not capable of determining 3-D shape. The workhorse of the semiconductor industry, scatterometry, is another optics-based technique widely used for measurement of shallow repeated structures, but is limited in its ability for 3-D shape analysis of deeper and/or isolated HAR targets [13]. Model based infrared reflectometry (MBIR) technique is reported to measure depth, top and bottom critical dimensions of TSVs and HAR targets [46]. But MBIR technique also relies on simulations similar to scatterometry and is limited in its ability for dimensional analysis of individual HAR targets. There seems to be a gap in HVM metrology tools for complete shape analysis of truly 3-D or HAR targets. It would be advantageous if the tool also does not rely on optical simulations.
We demonstrate here how a NIST-developed optics-based metrology tool, through-focus scanning optical microscopy (TSOM) [18, 44, 45, 47–56], could fill this gap. The TSOM image is generated from a set of images, each captured at a slightly different focus (i.e., through-focus), using a low-cost, conventional optical microscope. Thus, TSOM collects and preserves the entire through-focus optical intensity information in 3-D space. The collected set of through-focus two-dimensional optical images are then stacked at their respective focus positions creating a 3-D space filled with the optical intensities. From this 3-D space, extracting and plotting the optical intensities in a vertical cross-sectional plane results in a TSOM image. In the TSOM image, the X and the Y axes represent the distance and the focus positions, respectively. The color represents the optical intensity. A TSOM image depicts variations in the optical intensities with focus position. The color pattern enables visualization of the variations in the optical intensities easily. The TSOM images were then normalized [53, 57, 58]. The normalization procedure nearly eliminates the effect of variations in the experimental conditions such as the illumination source intensity, camera exposure time, frame rate. However, it is advisable to optimize conditions to reduce noise [58, 59].
D-TSOM images are generated by taking a pixel-by-pixel difference between two TSOM images obtained using two different targets. D-TSOM images expose small (down to sub-nanometer) differences embedded in nominally identical targets. The color patterns of D-TSOM images are usually distinct for different types of parameter changes and serve as a “fingerprint” for different types of parameter variations. D-TSOM images are qualitatively similar for different magnitude changes in the same parameter. However, the optical content of D-TSOM images is proportional to the magnitude of the dimensional differences. We developed a metric we call the Optical Intensity Range (OIR), which provides a quantitative estimate of the difference between two images. The OIR is the absolute optical range (i.e., the difference between the maximum and the minimum optical intensity) of the D-TSOM image, multiplied by 100 [53, 57]. The utility of D-TSOM [18, 48, 53, 54, 60] is that the color pattern of the D-TSOM image is an indicator of the difference in 3D shape, while the magnitude of the OIR scales with the dimensional difference between the two targets. Developments in image acquisition techniques have significantly reduced the acquisition time for a set of through-focus images to be as fast as a single conventional microscope image [51, 55, 61–63] making TSOM suitable for HVM.
Here we present a comprehensive study that demonstrates applicability of TSOM for shape analysis of truly 3 D trench targets with HAR. We show that the scattered light, which could be due to multiple scattering, contains the 3 D shape information. TSOM facilitates extraction of this useful information and allows us to propose a simple, cost-effective, non-destructive, 3 D shape process control method.
2. METHODS
2.1. HAR target fabrication
The current work uses a 300 mm silicon wafer with HAR targets in a SiO2 layer. First, a 1.1 μm thick SiO2 film was deposited on the silicon wafer. HAR features covering an area of 150 μm × 150 μm were etched into the oxide film with a nominal CD, depth and pitch of 100 nm, 1,100 nm and 1,000 nm, respectively. Exposure and etch conditions were varied across the wafer, as shown in Fig. 1(a), to provide slight variations in the feature structural parameters. This provides a systematic dimensional variation in the HAR targets across the wafer. Typical SEM, and optical images are shown in Figs. 1(b), and 1(c), respectively.
Fig. 1.
(a) Exposure and etch conditions used to fabricate the HAR wafer. Exposure time increases from left to right. Etching changes radially, being slower at the edges. Typical (b) SEM, (c) optical, (d) dual-beam FIB etched cross-sectional SEM, (e) TSOM, and (f) D-TSOM images. The color scale bars in (e) and (f) represent the optical intensity. Nominal pitch = 1,000 nm. Optical data acquisition conditions λ = 520 nm, numerical apertures (NA) = 0.75, illumination NA (INA) = 0.25.
2.2. FIB cross-section
Cross-sectional analysis of the HAR targets was performed using a focused ion beam scanning electron microscope (FIB SEM) equipped with a gas injection system. First, the HAR target areas were filled with Pt using the primary electron beam at 10 keV landing energy and with 1.6 nA beam current at 0° sample stage tilt. Once the targets were filled in, additional 1 μm thick Pt layer was deposited using the 30 keV, 800 pA ion beam. This layer was deposited to protect the sample surface during the cross-sectioning steps. Rough milling to remove the bulk of the material was performed at 2.5 nA ion beam current. The exposed cross-sectional face was further cleaned with a lower ion beam current (0.79 nA) fine milling. The cross-sectional face was imaged using a 2 keV, 100 pA electron beam with a through-the-lens detector (TLD) in immersion mode. A typical cross-sectional image thus obtained is shown in Fig. 1(d).
The following procedure was used to determine the precise cross-sectional profiles of the HAR targets. A typical large-area FIB cross-sectional image is shown in Fig. 2(a). A highly magnified cross-sectional profile of a single HAR trench is shown in Fig. 2(b). A line was first drawn along the SiO2-Si interface at the bottom (a1 in Fig. 2(b)). A perpendicular line (blue wide bar with a yellow central line) was drawn to this boundary passing through the middle of the trench at one-third of the distance from the top (a2 in Fig. 2(b)). Eleven horizontal lines were drawn at the predefined depths covering the entire depth of the trench (a3 Fig. 2(b)). Distances of the left and right profiles from the central vertical line were then carefully measured at the eleven horizontal line locations, providing the crosssectional profile of the trenches. A cubic spline fit was drawn through the eleven points on the left and the right separately resulting in the left and right profiles. For each die, a minimum of six such profile measurements were made on six different trenches. The final cross-sectional profile is a mean of these six measurements. The mean cross-sectional profile obtained in such a manner is shown in Fig. 3 (blue profile) for the central reference die along with the standard deviation which is shown as red profiles. The lowest measured cross-sectional profile standard deviation was observed at about one-third of the depth from the top as highlighted by a red box in the graph with the expanded x-scale, on the right of Fig. 3.
Fig. 2.
(a) A typical FIB cross-sectional image. (b) A typical high magnification cross-sectional image with horizontal lines at the depths at which profile measurements were taken (a3).
Fig. 3.
Measured mean cross-sectional profile of the target in the central die. Red profiles indicate mean standard deviations of all the profiles.
2.3. TSOM Experiments
A commercially-available conventional, bright-field optical microscope in the reflection mode was used to collect the TSOM images. The optical microscope was designed for Kohler illumination. A light emitting diode (LED) was used as an illumination source. A narrow, band-pass filter was used to obtain an illumination wavelength of 520 nm (±5 nm). TSOM images were captured using a 40× magnification objective with 0.75 numerical aperture (NA) and 0.25 illumination NA. An image of approximately 55 μm × 40 μm was captured using a cooled, monochrome CCD camera (692 × 520 pixels). A width of 0.5 μm (along the trenches) of the image at the center of the field-of-view (FOV) was averaged to obtain a mean intensity profile. From this, 2 μm length (across the trenches) at the center of the extracted profile was used from all of the through-focus images to construct the TSOM images. A through-focus step height of 300 nm, and a total through-focus scan range of 25 μm was used to collect the set of through-focus images. The experimental data were collected using 0° illumination polarization (E-field perpendicular to the trenches) which provided higher sensitivity. Other typical processing conditions used and the effect of optical parameters can be found in [57, 58]. The through-focus optical images forming the 3-D optical data set were analyzed using an in-house developed software program.
TSOM data were collected at the center of the target. Three sets of TSOM data from the 80 usable dies across the wafer were collected. For this work, we considered the target in the center die (0,0) as the reference. The TSOM image processing and normalization procedure can be found in earlier publications [57, 58]. An example of one TSOM image is shown in Fig. 1(e). D-TSOM images were evaluated by subtracting the TSOM image of the reference target from each of the TSOM images associated with the targets in the other 80 dies. A typical D-TSOM image is shown in Fig. 1(f); note the scale on the color bar as compared to that of Fig. 1(e).
3. RESULTS AND DISCUSSION
3.1. TSOM data
Even though we expect to see variation between the targets due to the process variation shown in Fig. 1(a), the color patterns for the TSOM images appear to be nearly identical for all the targets on the different dies. In contrast with the TSOM images, the color patterns of the D-TSOM images vary substantially based on the die selected. Typically, a sub-section of the D-TSOM image as highlighted by a red rectangle in Fig. 1(f) contains the strongest color pattern. Hence, we selected this sub-section (maintaining the same focus and distance ranges) from all the D-TSOM images and created a mosaic of the D-TSOM images by placing them in their respective die locations covering the entire wafer as shown Fig. 4(a). Please note that these D-TSOM images are set to automatically scale the color to highlight the color patterns.
Fig. 4.
TSOM results. (a) A mosaic of the D-TSOM images obtained by subtracting the TSOM image of the central reference target from the TSOM images of the targets in the other dies with color scale bar set to automatic. (b) Four major types of D-TSOM image color patters identified. (c) OIR values of the D-TSOM images representing the automatic color scale ranges in (a). Standard deviations of these OIR values varies between 2 % to 10 %, with the majority of them falling below 5 %. Each die can be uniquely identified using the assigned co-ordinates in (a) and (c).
At a first glance, the D-TSOM image color patterns appear to be varying widely. However, careful observation shows that they are mostly variations of the four basic color patterns (T1, T2, T3 and T4) as identified in Fig. 4(b). Fig. 4(c) converts the ranges of optical strength in the D-TSOM images into OIR values, which are set at their respective die locations.
One can see that the upper semicircle of Fig. 4(a) is mostly filled with T1 or T2 types of 3D shape differences and the lower semicircle is mostly filled with T3 or T4 types of differences. Further, the larger OIR of the D-TSOM images on the right side of the semicircle in Fig. 4(c) indicates larger dimensional difference targets compared to the left side of the semicircle. While these observations suggest how much the different HAR structures vary, one needs additional information to know what type of shape or dimensional differences the T1, T2, T3 and T4 type of D-TSOM images represent.
3.2. 3-D profile analysis with TSOM
For the purposes of this analysis, we compared information collected using D-TSOM and FIB-SEM cross-section. After comparing the cross-sectional profiles of the selected reference targets, a correlation between the D-TSOM images and the geometry was identified. A summary of this correlation is presented in Fig. 5. The four typical types of D-TSOM images identified in Fig. 4(b) can be correlated with the following cross-sectional characteristics:
Fig. 5.
A summary showing four major D-TSOM images (a1, b1, cl, and d1), their corresponding FIB-cross sectional shape profiles (a2, b2, c2 and d2) and types of simplified shapes (a3, b3, c3, and d3) represented as T1, T2, T3, and T4 in (a), (b), (c), and (d), respectively. In (a2, b2, c2, and d2) the blue color profile is from the reference target, while the red color profile is from the production target. Different types of 3-D profile differences between the reference and the production targets result in D-TSOM images with different color patterns.
Type T1 D-TSOM image (Fig. 5(a1)): It is associated with mostly symmetric profile differences from top to bottom, with nearly similar width at the top but narrower width of the production target at the bottom (Fig. 5(a2)). Schematically we can represent this type of difference as shown in Fig. 5(a3).
Type T2 D-TSOM image (left part of Fig. 5(b1)): It is associated with mostly asymmetric profile differences from top to bottom, with nearly similar width at the top but narrower width of the production target at the bottom (Fig. 5(b2)). Schematically we can represent this type of difference as shown in Fig. 5(b3). Since the profile differences are similar to Fig. 5(a2), except with asymmetry, we can propose that T2 type of D-TSOM image is a result of T1 type of profile differences with some asymmetry present. This is presented in Fig. 5(b1).
Type T3 D-TSOM image (Fig. 5(c1)): It is associated with mostly symmetric profile differences from top to bottom with production target wider at the top but narrower at the bottom (Fig. 5(c2)). Schematically we can represent this type of difference as shown in Fig. 5(c3).
Type T4 D-TSOM image (left part of Fig. 5(d1)): It is associated with mostly asymmetric profile differences from top to bottom, with the production target wider at the top but narrower at the bottom (Fig. 5(d2)). Schematically we can represent this type of difference as shown in Fig. 5(d3). Since the profile differences are similar to Fig. 5(c2), except with asymmetry, we can propose that T4 type of D-TSOM image is a result of T3 type of profile differences with some asymmetry present. This is presented in Fig. 5(d1).
3.3. Process monitoring with TSOM
From these results, we identify two paths to the desired fast, low-cost, inline capable, automated, robust, easy to use, non-destructive and statistically significant metrology tool for a high-volume production environment. For the sake of argument, we can consider the target in the central die (the reference target (0,0)) as an ideal target with desirable dimensions. In a production environment, this information would be available from a “golden” standard or reference. We consider the targets in the rest of the dies as exhibiting dimensional variations, as it would be typical in production.
3.3.1. First approach.
As the first approach, we propose using only the OIR values for the process monitoring. In earlier work, we showed that the magnitude of the OIR increases with the magnitude of the dimensional difference [18, 48, 53] between the reference and target under test. Thus, in production we can identify a maximum OIR value for an acceptable production target, for which, when exceeded, an unacceptable percentage of the related devices will fail.
This first approach is an example of high-throughput and quick way of using TSOM as a simple 3D shape process monitoring method. However, it has the drawback of not identifying the type of dimensional difference the D-TSOM image represents. Since there are several types of D-TSOM image color patterns in Fig. 4, we can expect many types of 3D shape deviations from the reference target. From the OIR alone we are unable to single-out deviation in the dimension that is critical (usually called the critical dimension) for the application. A small deviation in the critical dimension may not be acceptable, whereas a larger deviation in a non-critical dimension may be acceptable. If the process monitoring is done purely based on the OIR values, there is a possibility that useable targets may be rejected if the high OIR value of a D-TSOM image is a result of a large non-critical dimensional difference, and vice versa.
3.3.2. Second approach.
The second course of action allows us to make intelligent process monitoring decisions with enhanced accuracy using the knowledge gained by determining the correlation between the color pattern in the D-TSOM image and the type of dimensional difference. This analysis needs determination of the complete 3D shape of targets corresponding to specific families of TSOM images. This process is similar to the library development in scatterometry, which is widely used in high-volume manufacturing. However, in the TSOM method we make use of experimentally generated library where as in the case of scatterometry optical simulations are used. For this work we developed such a library using the FIB SEM cross-sectional images described above and shown in Fig. 3, as well as those having similar patterns but exhibiting a range of OIR values. The D-TSOM images and the evaluated profile correlations become a library for the second approach.
Equipped with the information and correlations identified in Fig. 5, we then propose the following steps for 3-D shape process control of the HAR targets:
At first, we create accept/reject rules. These rules should be based on the process control requirement. For the sake of demonstration, we have created the following rules randomly (these rules are shown graphically in Fig. 6). If the OIR of the D-TSOM image is more than 12, reject the target as the dimensional differences are in excess of the tolerable limits. On the lower side, if the OIR of the D-TSOM image is less than 7, accept the target as the dimensional differences are within the acceptable level. If the OIR value is in between 7 and 12, reject the production target if the profiles are asymmetric and accept if the profiles are symmetric.
Now consider a random production target, for example the one located at position (−2,2) in Fig. 4. Initially, we have no knowledge of the type of target shape deviation from the reference target. Since its OIR value is 8.4, we then proceed to the next step where its D-TSOM image is compared with the reference library to determine which D-TSOM image from the library matches best with it. This target shows highest correlation with type T1 D-TSOM image; this can be determined by calculating the correlation coefficients by comparing the D-TSOM image with each reference image in the library. In this case, the best correlation of the target at (−2, 2) is with the type T1 (Fig. 5(a)). Since this target has a mostly symmetric shape difference and its OIR value is less than 12, the final verdict is “Acceptable.” Figure 7 illustrates this decision process as row number 1. We can unambiguously bin (accept/reject) the unknown targets at positions (1, −4), (−2, 1), and (4,2), following the similar decision process as depicted in rows 2, 3, and 4, respectively, using only the OIR values and the correlation coefficients.
Fig. 6.
Process control rules arbitrarily selected for demonstration purposes
Fig. 7.
Proposed TSOM-based automated 3-D-shape process control method. The selected test production targets in column 1 are considered to have unknown 3-D-shape profile (column 2). Comparing the D-TSOM images of the test targets with the library provides the best match (green boxes) from which the possible 3D shape difference type can be inferred (column 8). Based on the type of 3-D shape difference and the magnitude of the dimensional difference (OIR), the process control decision of accept/reject status can be made.
The unknown target in row 3, (−2, 1), has the highest correlation coefficient with T2. However, its correlation coefficient is also close to type T1. Similar, but still-high correlation with T1 and T2 indicates that the unknown target is type T1 with asymmetry, i.e., type T2. Since correlation coefficients derived from D-TSOM images and OIR values are all numerical values, the decision process is simple and can easily be automated. The remaining acceptable dies after applying the selected process control rules to the wafer shown in Fig. 4 are presented in Fig. 8.
Fig. 8.
Dies marked by an X are rejected after applying the automated TSOM-based process control criteria of Figure 7 to the entire wafer shown in Figure 2, using the created rules (Fig. 6). The rest of the dies are deemed acceptable.
3.3.3. Verification of the 3-D shape analysis
Here we present a test case to verify the accuracy of the TSOM method of process control (Fig. 9). We chose two die locations (−2,2) and (3,0) that show type T1 D-TSOM images but with different magnitude of OIR values of 8.4 and 12.4, respectively. Since both the dies have type T1 profile differences, their cross-sectional profile differences should be similar when compared to the reference profile. However, the target in die (3,0) with a higher OIR value should have a larger profile difference compared to the target in die (−2,2). Measured FIB cross-sectional profiles shown in Fig. 9 support this, i.e., a larger difference in the profile results in a larger OIR, validating the analysis made by the TSOM method.
Fig. 9.
Cross-sectional profiles overlaid for targets from the reference die (blue profile), Die (−2,2) (green profile), and die (3,0) (red profile).
3.3.4. Large area and intra-die analysis
The TSOM method can also be used to identify anomalies in targets covering a large area. In Fig. 10, we present 50 μm long HAR sample SEM (Fig. 10(a)) and D-TSOM (Fig. 10(b)) images. While the D-TSOM image pattern typically matches with type T1, which is mostly symmetrical profile differences, some local variations can be identified. We highlighted two of the several local variations in the D-TSOM image by the red boxes. In Fig. 10(c), the red color area between the two blue color regions is less dominant in the highlighted blue box, whereas in Fig. 10(d), it is more dominant. This difference is a result of the underlying localized cross-sectional profile (i.e., 3-D) shape differences. Even though at present it is not known what type of profile differences result in this type of D-TSOM images, this demonstrates the ability of the TSOM method to highlight them easily. A further finer localized FIB-cross sectional analysis would reveal the underlying profile shape differences precisely. A similar process can also be applied to identify dimensional variations within a die. In this way, localized variations (or defects) within a large area that fits in the FOV of a microscope can be identified simultaneously using the TSOM method.
Fig. 10.
Large area analysis using TSOM. (a) A typical top-down SEM image of a 50 μm long HAR sample. (b) D-TSOM image obtained using die (3,1) and the reference die. (c) and (d) Magnified areas highlighted by red boxes in (b) showing differences in the localized color patterns.
TSOM has unique advantages over other metrologies such as scatterometry, as it can be used to independently analyze every 3-D structure (such as the HAR target demonstrated here); and over metrologies such as SEM, as it can be used to simultaneously analyze a large number of targets present in a large field-of-view (FOV) of a microscope with measurement resolution comparable to SEMs and AFMs. TSOM can also be used to study dimensional variations within a die, not possible with either scatterometry or MBIR. It is also not possible to obtain 3-D shape information using SEM non-destructively, and measure narrow spaces using AFM due to probe size limitations. In the case presented here we have demonstrated that TSOM does not have these two limitations.
This paper demonstrates the basic 3-D shape process control procedure using the TSOM method, wherein each step can be automated once the library is generated. In the case presented here, the library has only four major types of D-TSOM images. For other cases, there may be more or less major types of D-TSOM images in the library. However, we expect the same type of procedure to work for 3-D shape process control of many types of shapes and target sizes, ranging from micro-scale to nano-scale targets.
4. CONCLUSION
In this paper, we have shown how TSOM could be applied in a high-volume manufacturing environment by using numerical signatures from measured D-TSOM images that have been developed into a reference library or database. Thus, we have proposed and demonstrated a low-cost, high-throughput, and nondestructive 3-D shape process monitoring method for truly 3-D or HAR type of targets using conventional optical microscopes. This tool can fill the gap by satisfying the HVM metrology needs of not only HAR but also other types of truly 3-D targets for which 3-D shape process control/monitoring is needed. This work indicates that targets with surfaces hidden from the direct illumination could also be analyzed using TSOM. We have also pointed out that TSOM has unique advantages over other metrologies such as scatterometry, and SEM.
Acknowledgment.
We thank Dr. John Kramar for his suggestions, and Dr. Emil Agocs for his help.
REFERENCES
- [1].Postek MH, Robert 2004 Instrumentation and metrology for nanotechnology. [Google Scholar]
- [2].Picotto GB, Koenders L and Wilkening G 2009. Nanoscale metrology Measurement Science and Technology 20 080101 [Google Scholar]
- [3].Leach RK, Boyd R, Burke T, Danzebrink HU, Dirscherl K, Dziomba T, Gee M, Koenders L, Morazzani V, Pidduck A, Roy D, Unger WES and Yacoot A 2011. The European nanometrology landscape Nanotechnology 22 [DOI] [PubMed] [Google Scholar]
- [4].Hausler G and Ettl S 2011. Optical Measurement of Surface Topography, ed Leach R: Springer; Berlin Heidelberg: ) pp 23–48 [Google Scholar]
- [5].Zhang X, Zhou H, Ge Z, Vaid A, Konduparthi D, Osorio C, Ventola S, Meir R, Shoval O, Kris R, Adan O and Bar-Zvi M 2014. Addressing FinFET metrology challenges in 1× node using tilt-beam critical dimension scanning electron microscope MOEMS 13 041407- [Google Scholar]
- [6].Schulmeyer I, Lechner L, Gu A, Estrada R, Stewart D, Stern L, McVey S, Goetze B, Mantz U and Jammy R 2016. Advanced metrology and inspection solutions for a 3D world25–27April 2016) p 1–2 [Google Scholar]
- [7].Arceo A, Bunday B, Cordes A and Vartanian V 2012. Evolution or revolution: the path for metrology beyond the 22nm node Solid State Technol 55 15–9 [Google Scholar]
- [8].Crimmins TF 2010. Defect metrology challenges at the 11-nm node and beyond(vol 7638) p 76380H-H–12 [Google Scholar]
- [9].Takamasu K, Iwaki Y, Takahashi S, Kawada H, Ikota M, Lorusso GF and Horiguchi N 2016. 3D-profile measurement of advanced semiconductor features by reference metrology(vol 9778) p 97781T-T–8 [Google Scholar]
- [10].Attota R, Silver R and Barnes BM 2008. Optical through-focus technique that differentiates small changes in line width, line height and sidewall angle for CD, overlay, and defect metrology applications Metrology, Inspection, and Process Control for Microlithography Xxii, Pts 1 and 2 6922 [Google Scholar]
- [11].Vaid A, Elia A, Iddawela G, Bozdog C, Sendelbach M, Kang BC, Isbester PK and Wofling S 2014. Hybrid metrology: from the lab into the fab MOEMS 13 041410- [Google Scholar]
- [12].Bunday B. HVM Metrology Challenges towards the 5 nm Node. Metrology, Inspection, and Process Control for Microlithography. 2016;Xxx:9778. [Google Scholar]
- [13].Bunday B, Germer TA, Vartanian V, Cordes A, Cepler A and Settens C 2013. Gaps Analysis for CD Metrology Beyond the 22 nm Node Metrology, Inspection, and Process Control for Microlithography Xxvii 8681 [Google Scholar]
- [14].Allen RA, Vartanian V, Read D and Baylies W 2014. (Invited) Metrology for 3D Integration Ecs Transactions 61 105–12 [Google Scholar]
- [15].Vartanian V, Allen RA, Smith L, Hummler K, Olson S and Sapp B 2014. Metrology needs for through-silicon via fabrication J Micro-Nanolith Mem 13 [Google Scholar]
- [16].Jo T, Kim S and Pahk H 2013. 3D Measurement of TSVs Using Low Numerical Aperture White-Light Scanning Interferometry J OptSoc Korea 17 317–22 [Google Scholar]
- [17].Ku YS, Shyu DM, Hsu WT, Chang PY, Chen YC and Pang HL 2011. 3D Interconnect metrology in CMS/ITRI Optical Measurement Systems for Industrial Inspection Vii 8082 [Google Scholar]
- [18].Attota R, Dixson RG, Kramar JA, Potzick JE, Vladar AE, Bunday B, Novak E and Rudack A 2011. TSOM Method for Semiconductor Metrology Proc. SPIE 7971 79710T [Google Scholar]
- [19].Schroettner H, Schmied M and Scherer S 2006. Comparison of 3D surface reconstruction data from certified depth standards obtained by SEM and an infinite focus measurement machine (IFM) Microchimica Acta 155 279–84 [Google Scholar]
- [20].Punge A, Rizzoli SO, Jahn R, Wildanger JD, Meyer L, Schonle A, Kastrup L and Hell SW 2008. 3D reconstruction of high-resolution STED microscope images Microsc Res Techniq 71 644–50 [DOI] [PubMed] [Google Scholar]
- [21].Wildanger D, Medda R, Kastrup L and Hell SW 2009. A compact STED microscope providing 3D nanoscale resolution J Microsc-Oxford 236 35–43 [DOI] [PubMed] [Google Scholar]
- [22].Cuijpers VMJI, Walboomers XF and Jansen JA 2011. Scanning Electron Microscopy Stereoimaging for Three-Dimensional Visualization and Analysis of Cells in Tissue-Engineered Constructs: Technical Note Vssue Eng Part C-Me 17 663–8 [DOI] [PubMed] [Google Scholar]
- [23].Kramar JA, Dixson R and Orji NG 2011. Scanning probe microscope dimensional metrology at NIST Meas Sci Technol 22 [Google Scholar]
- [24].Orji NG, Dixson RG, Vladar AE and Postek MT 2011. Strategies for Nanoscale Contour Metrology using Critical Dimension Atomic Force Microscopy Proceedings of SPIE 8105 810505 [Google Scholar]
- [25].Carrero J and Percin G 2012. Accurate Optical CD Profiler Based On Specialized Finite Element Method Proceedings of SPIE 8324 83240P [Google Scholar]
- [26].Dai GL, Hassler-Grohne W, Huser D, Wolff H, Fluegge J and Bosse H 2012. New developments at Physikalisch Technische Bundesanstalt in threedimensional atomic force microscopy with tapping and torsion atomic force microscopy mode and vector approach probing strategy J Micro-Nanolith Mem 11 [Google Scholar]
- [27].Kopek BG, Shtengel G, Xu CS, Clayton DA and Hess HF 2012. Correlative 3D superresolution fluorescence and electron microscopy reveal the relationship of mitochondrial nucleoids to membranes P Natl Acad Sci USA 109 6136–41 [DOI] [PMC free article] [PubMed] [Google Scholar]
- [28].Vladar AE, Cizmar P, Villarrubia JS and Postek MT 2012. Can We Get 3D CD Metrology Right? Proceedings of SPIE 8324 832402 [Google Scholar]
- [29].Li J, Kritsun O, Dasari P, Volkman C, Wallow T and Hu JT 2013. Evaluating Scatterometry 3D Capabilities for EUV Proceedings of SPIE 8681 86810S [Google Scholar]
- [30].Qin J, Silver RM, Barnes BM, Zhou H and Goasmat F 2013. Fourier domain optical tool normalization for quantitative parametric image reconstruction Appl Optics 52 6512–22 [DOI] [PubMed] [Google Scholar]
- [31].Sunday DF, Hammond MR, Wang CQ, Wu WL, Kline RJ and Stein GE 2013. Three-dimensional x-ray metrology for block copolymer lithography line-space patterns J Micro-Nanolith Mem 12 [Google Scholar]
- [32].Yamaguchi A, Ohashi T, Kawasaki T, Inoue O and Kawada H 2013. Three-dimensional profile extraction from CD-SEM image and top/bottom CD measurement by line-edge roughness analysis Proceedings of SPIE 8681 86812Z [Google Scholar]
- [33].Chao R, Kohli KK, Zhang YL, Madan A, Muthinti GR, Hong AJ, Conklin D, Holt J and Bailey TC 2014. Multitechnique metrology methods for evaluating pitch walking in 14 nm and beyond FinFETs J Micro-Nanolith Mem 13 [Google Scholar]
- [34].Guo HX, Itoh H, Wang CM, Zhang H and Fujita D 2014. Focal depth measurement of scanning helium ion microscope Appl Phys Lett 105 [Google Scholar]
- [35].Ku YS. Spectral reflectometry for metrology of three-dimensional through-silicon vias. J Micro-Nanolith Mem. 2014;13 [Google Scholar]
- [36].Silver RM, Barnes BM, Zhang NF, Zhou H, Vladar A, Villarrubia J, Kline J, Sunday D and Vaid A 2014. Optimizing Hybrid Metrology through a Consistent Multi-Tool Parameter Set and Uncertainty Model Proceedings of SPIE 9050 905004 [Google Scholar]
- [37].Vladar AE, Villarrubia JS, Chawla J, Ming B, Kline JR, List S and Postek MT 2014. 10 nm Three-Dimensional CD-SEM Metrology Proceedings of SPIE 9050 90500A [Google Scholar]
- [38].Zhang XX, Zhou H, Ge ZH, Vaid A, Konduparthi D, Osorio C, Ventola S, Meir R, Shoval O, Kris R, Adan O and Bar-Zvi M 2014. Addressing FinFET metrology challenges in 1× node using tilt-beam critical dimension scanning electron microscope J Micro-Nanolith Mem 13 [Google Scholar]
- [39].Attota R, Silver RM, Bishop MR and Dixson RG 2006. Optical critical dimension measurement and illumination analysis using the through-focus focus metric - art. no. 61520K P Soc Photo-Opt Ins 6152 K1520–K [Google Scholar]
- [40].Attota R, Silver RM, Stocker M, Marx E, Jun J, Davidson M and Larrabee R 2003. A new method to enhance overlay tool performance Metrology, Inspection, and Process Control for Microlithography Xvii, Pts 1 and 2 5038 428–36 [Google Scholar]
- [41].Orji NG, Dixson RG, Ng BP, Vladar AE and Postek MT 2016. Contour metrology using critical dimension atomic force microscopy J Micro-Nanolith Mem 15 [Google Scholar]
- [42].Heurlin M, Anttu N, Camus C, Samuelson L and Borgstrom MT 2015. In Situ Characterization of Nanowire Dimensions and Growth Dynamics by Optical Reflectance Nano Lett 15 3597–602 [DOI] [PubMed] [Google Scholar]
- [43].Vaid A, Yan BB, Jiang YT, Kelling M, Hartig C, Allgair J, Ebersbach P, Sendelbach M, Rana N, Katnani A, Mclellan E, Archie C, Bozdog C, Kim H, Sendler M, Ng S, Sherman B, Brill B, Turovets I and Urensky R 2011. A holistic metrology approach: hybrid metrology utilizing scatterometry, CD-AFM, and CDSEM(vol 7971): SPIE; ) p 20 [Google Scholar]
- [44].Association S I 2016. The International Technology Roadmap for Semiconductors (ITRS) (San Jose: Semiconductor Industry Association; ) [Google Scholar]
- [45].IEEE 2018. International Roadmap for Devices and Systems 2017 Edition: Metrology. IEEE; ) [Google Scholar]
- [46].Cunf DL, Höglund LJ and Laurent N 2011. In-line metrology of high aspect ratio structu with MBIR technique16–18 May 2011) p 1–5 [Google Scholar]
- [47].Attota R, Germer TA and Silver RM 2008. Through-focus scanning-optical-microscope imaging method for nanoscale dimensional analysis Opt Lett 33 1990–2 [DOI] [PubMed] [Google Scholar]
- [48].Attota R and Silver R 2011. Nanometrology using a through-focus scanning optical microscopy method Meas Sci Technol 22 [Google Scholar]
- [49].Attota R, Bunday B and Vartanian V 2013. Critical dimension metrology by through-focus scanning optical microscopy beyond the 22 nm node Appl Phys Lett 102 [Google Scholar]
- [50].Ryabko M, Koptyaev S, Shcherbakov A, Lantsov A and Oh SY 2014. Motion-free all optical inspection system for nanoscale topology control Opt Express 22 14958–63 [DOI] [PubMed] [Google Scholar]
- [51].Han S, Yoshizawa T, Zhang S, Lee JH, Park JH, Jeong D, Shin EJ and Park C 2016. Tip/tilt-compensated through-focus scanning optical microscopy Proc. of SPIE 10023 100230P [Google Scholar]
- [52].Taute KM, Gude S, Tans SJ and Shimizu TS 2015. High-throughput 3D tracking of bacteria on a standard phase contrast microscope Nature Communications 6 [DOI] [PMC free article] [PubMed] [Google Scholar]
- [53].Attota R and Dixson RG 2014. Resolving three-dimensional shape of sub-50 nm wide lines with nanometer-scale sensitivity using conventional optical microscopes Appl Phys Lett 105 [Google Scholar]
- [54].Arceo A, Bunday B, Vartanian V and Attota R 2012. Patterned Defect & CD Metrology by TSOM Beyond the 22 nm Node Proc Spie 8324 [Google Scholar]
- [55].Park S-w, Park G, Kim Y, Cho JH, Lee J and Kim H 2018. Through-focus scanning optical microscopy with the Fourier modal method Opt Express 26 11649–57 [DOI] [PubMed] [Google Scholar]
- [56].2013. SEMI 3D5–0613 Guide For Metrology Techniques To Be Used In Measurement Of Geometrical Parameters Of Through- Silicon Vias (TSVs) In 3DS-IC Structures In: SEMI3D5–0613: SEMI; ) [Google Scholar]
- [57].Attota RK and Kang H 2016. Parameter optimization for through-focus scanning optical microscopy Opt Express 24 14915–24 [DOI] [PubMed] [Google Scholar]
- [58].Attota R 2016. Noise analysis for through-focus scanning optical microscopy Opt Lett 41 745–8 [DOI] [PMC free article] [PubMed] [Google Scholar]
- [59].Attota R and Kramar J 2016. Optimizing noise for defect analysis with through-focus scanning optical microscopy Proc. SPIE 9778 977811. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [60].Attota RK, Weck P, Kramar JA, Bunday B and Vartanian V 2016. Feasibility study on 3-D shape analysis of high-aspect-ratio features using through-focus scanning optical microscopy Opt Express 24 16574–85 [DOI] [PMC free article] [PubMed] [Google Scholar]
- [61].Gineste JM, Macko P, Patterson EA and Whelan MP 2011. Three-dimensional automated nanoparticle tracking using Mie scattering in an optical microscope Journal of microscopy 243 172–8 [DOI] [PubMed] [Google Scholar]
- [62].Abrahamsson S, Chen JJ, Hajj B, Stallinga S, Katsov AY, Wisniewski J, Mizuguchi G, Soule P, Mueller F, Darzacq CD, Darzacq X, Wu C, Bargmann CI, Agard DA, Dahan M and Gustafsson MGL 2013. Fast multicolor 3D imaging using aberration-corrected multifocus microscopy Nat Methods 10 60–U80 [DOI] [PMC free article] [PubMed] [Google Scholar]
- [63].Attota RK. Through-focus or volumetric type of optical imaging methods: a review. J Biomed Opt. 2018;23 doi: 10.1117/1.JBO.23.7.070901. In press. [DOI] [PMC free article] [PubMed] [Google Scholar]