Skip to main content
PLOS ONE logoLink to PLOS ONE
. 2019 May 16;14(5):e0216655. doi: 10.1371/journal.pone.0216655

Prospective assessment of inter- or intra-fractional variation according to body weight or volume change in patients with head and neck cancer undergoing radiotherapy

Seong Hoon Kim 1,2,‡,#, Se An Oh 2,‡,#, Ji Woon Yea 1,2, Jae Won Park 1,2,*
Editor: Hyunseok Kang3
PMCID: PMC6522006  PMID: 31095583

Abstract

This study aimed to prospectively investigate the association between body weight (ΔBW) or body volume variations (ΔBV) and inter- or intra-fractional variations (Δ(inter) or Δ(intra)) in patients with head and neck cancer (HNC) undergoing radiotherapy (RT). This study enrolled patients with HNC from December 2015 to December 2017. All patients underwent curative intensity-modulated RT (IMRT) either as definitive or adjuvant treatment. Six-dimensional inter- and intra-fractional variations (Δ(inter) and Δ(intra)) were obtained with ExacTrac (BrainLAB, Feldkirchen, Germany) system. BV was measured 7.5 cm cranio-caudally from the centre using cone beam computed tomography. The BW, BV, and Δ(inter) were calculated based on the value obtained on the first treatment day after each simulation. Both Δ(inter) and Δ(intra) were considered in calculating the optimal margins for planning target volume (PTV), which was calculated using van Herk’s formula. In total, 678 fractions with 39 simulations in 22 patients were analysed. The average ΔBW and ΔBV was -0.43±1.90 kg (range, -7.3 to 5.0) and -24.34±69.0 cc (range, -247.15 to 214.88), respectively. In correlation analysis, Δ(intra) was more associated with ΔBW or ΔBV than Δ(inter). Receiver operating characteristic analysis showed Δ(intra) could differentiate ΔBW from ΔBV, while Δ(inter) could not. The optimal margins for PTV considering both Δ(inter) and Δ(intra) were 3.70 mm, 4.52 mm, and 5.12 mm for the right-left, superior-inferior, and anterior-posterior directions, respectively. In conclusion, the PTV margin of 6 mm for anterior-posterior direction and 5 mm for the other directions were needed. ΔBW or ΔBV correlated with Δ(intra) rather than Δ(inter). Therefore, ΔBW or ΔBV should be assessed for accurate IMRT in patients with HNC.

Introduction

A multimodal approach that includes radiotherapy (RT) is important for the successful treatment of head and neck cancer (HNC) [1]. Intensity-modulated radiotherapy (IMRT) has recently become the preferred modality for radiotherapy in patients with HNC because it offers more conformal dose distribution. IMRT could spare the parotid glands, thus reducing the incidence of xerostomia [2]. However, the steep dose gradient of an IMRT plan poses a risk of marginal miss due to set-up error [3]. To compensate for this risk, a margin from the clinical target volume (CTV) is added to the planning target volume (PTV). However, although a larger margin lowers marginal misses, it also delivers a higher dose to organs at risk. Therefore, it is necessary to determine the optimal margin required clinically by accurately measuring the error.

Errors that can cause marginal misses can be divided into two types, namely, inter-fractional or intra-fractional variations (Δ(inter) or Δ(intra)). The Δ(inter) is caused by variations of the patient’s body [4] and set-up errors between each daily treatment. To correct for Δ(inter), image-guided radiotherapy (IGRT) is performed, which corrects the patient’s posture pre-treatment. Meanwhile, the Δ(intra) is mainly caused by the fine movement of the patients during RT [5,6].

Although RT is beneficial for HNC, it also results in dysphagia, odynophagia, dry mouth, and a loss of sense of taste, thus often leading to weight loss [7]. Chamchod et al. [8] reported that the mean posttreatment body mass index of patients with cancer is lower than that in pretreatment (28.5 ± 4.9 kg/m2 vs 26.2 ± 4.4 kg/m2 in men; 27.8 ± 8 kg/m2 vs. 26 ± 7.5 kg/m2 in women). Furthermore, in cases of cervical lymph node metastasis, the surface of the head and neck can change during RT [9]. Shrinkage of the parotid glands during RT has also been reported [10]. As the surfaces of the head and neck change, a gap may occur between the thermoplastic mask and the skin, which may increase potential error. Lai et al. [11] reported correlations between circumferences at the level of the mastoid tip and inter-fractional variations. However, the measurement in their study was performed only twice in the RT course and was also studied by measuring the length only in two dimensions rather than measuring by body volume (BV) in three-dimensions.

In this study, we measured the variation of body weight (BW, ΔBW), BV (ΔBV), Δ(inter) and Δ(intra) with the aim to determine the relationship between body indices (ΔBW or ΔBV) and set-up errors (Δ(inter) or Δ(intra)) to ultimately suggest an optimal margin for PTV from CTV in RT for HNC.

Materials and methods

Eligible patients

This study prospectively enrolled patients with histologically confirmed HNC who underwent curative IMRT either as definitive or adjuvant treatment. The enrolment period started from December 2015 and ended December 2017, and the target number of patients was 25. Those who were aged 18 years of or older were eligible for inclusion. Meanwhile, patients (1) requiring palliative RT, (2) with distant metastases, (3) with malignancies that do not benefit from IMRT (e.g., orbital lymphoma, early glottic cancer), (4) those who had been treated with RT for HNC or who had a history of malignancy other than the HNC for the past 5 years, and (5) those who refused IGRT were excluded.

This study was approved by the Institutional Review Board of Yeungnam University Medical Center (approval number: YUMC 2015-09-034) and was conducted according to the principles expressed in the Declaration of Helsinki. Written informed consent was obtained from all patients.

Immobilization and simulation

DUONTM (Orfit Industries, Wijnegem, Belgium) masks were used as immobilization devices (Fig 1). Bite block was used as needed. All patients were scanned using a Brilliance Big Bore CT simulator (Philips Inc., Cleveland, OH) with a thickness of 2.5 mm. If there was an Δ(intra) error of more than 3 mm in post-treatment ExacTrac (BrainLAB, Feldkirchen, Germany), repeated simulation was performed.

Fig 1. Image of immobilization and set-up.

Fig 1

Thermoplast masks were used for immobilization.

Treatment planning

An experienced radiation oncologist delineated the gross tumour volume and the CTV for each patient. The PTV was generated with a margin of 5 mm in the CTV. Nine-field static IMRT was generated with inverse planning using anisotropic analytical algorithm. The Eclipse 8.6 (Varian Medical System, Palo Alto, CA, USA) was used as the treatment planning system.

Image registration and setup protocol

For this study, the kV ExacTrac system and cone beam computed tomography (CBCT) using a kV on-board-imager were used for image guidance. The patients’ BW was measured during each treatment fraction. After the treatment position was set-up, the initial ExacTrac was performed. Image registration was performed using a digitally reconstructed radiograph (DRR) from the CT simulation image as described in our previous study [12]. Image registration was performed automatically based on the bony anatomy of the mandible and cervical spine using the region of interest (ROI) function with spyglass mode, checked by an experienced therapist and then confirmed by an experienced radiation oncologist with an offline review. Then, the correction based on the results of initial ExacTrac was applied to the 6D robotic couch system (BrainLAB, Feldkirchen, Germany). Repositioning was performed as necessary. After correction, pre-treatment ExacTrac and CBCT were performed. Correction via CBCT or pre-treatment ExacTrac was not allowed. Post-treatment ExacTrac was then performed. If an error exceeded 3 mm in any direction of the post-treatment ExacTrac, we performed repeated simulation.

Treatment delivery

All patients received IMRT treatments using a Novalis Tx (Varian Medical System, CA, USA) linear accelerator machine with HD-120 multi-leaf collimator. Also, photon energy of 6 MV for the radiation dose was delivered to tumour with a dose rate of 600 monitor units per minute.

Calculation of intra- and inter-fractional errors and body volume measurement

Six-dimensional (6D; right-left (RL), superior-inferior (SI), anterior-posterior (AP), pitch, roll, and yaw) inter-fractional variations (Δ(inter); ΔRL(inter), ΔSI(inter), ΔAP(inter), Δpitch(inter), Δroll(inter), and Δyaw(inter)) and intra-fractional variations (Δ(intra); ΔRL(intra), ΔSI(intra), ΔAP(intra), Δpitch(intra), Δroll(intra) and Δyaw(intra)) were obtained with the ExacTrac system. The Δ(inter) for RL, SI, AP, pitch, roll, and yaw directions was determined via the initial setup values of ExacTrac, and Δ(intra) for RL, SI, AP, pitch, roll, and yaw directions were obtained by subtracting the ExacTrac setup values of pre-treatment from the ExacTrac setup values of post-treatment. Three-dimensional vector of variations (Δ3D(inter)2 = ΔRL(inter)2 + ΔSI(inter)2 + ΔAP(inter)2, Δ3D(intra)2 = ΔRL(intra)2 + ΔSI(intra)2 + ΔAP(intra)2) were calculated. Eclipse 8.6 software was used for body volume measurement. The body volume was measured 7.5 cm in the superior and inferior directions from the centre of the CBCT (Fig 2), respectively. The ΔBW and ΔBV were calculated based on the values of body weight and body volume measured by CBCT, which were obtained on the first radiation treatment day. The schema of treatment procedure and calculation of body indices and set-up error is shown in Fig 3.

Fig 2. Body volume was measured using cone beam computed tomography.

Fig 2

The measurement range was 7.5 cm in the superior and inferior directions from the centre of the CBCT.

Fig 3. Schema of treatment procedure and calculation of body indices and set-up error.

Fig 3

Statistics

We used Pearson’s correlation analysis to determine the correlation between ΔBW and ΔBV. We also used Pearson’s correlation analysis for ΔBW or ΔBV and Δ(inter), Δ(intra), absolute value of Δ(inter), and absolute value of Δ(intra). Furthermore, receiver operating characteristic (ROC) analysis was performed to determine the optimal points of ΔBW or ΔBV for treatment in less than 3 mm of Δ(inter) or 2 mm of Δ(intra). Box plot of Δ(inter) or Δ(intra) for each group was created based on ΔBW of 1 kg. All analyses were performed using SPSS version 25.0 (IBM Inc., Armonk, NY, USA).

Recipes for optimal PTV margins

Margin recipes proposed by Stroom et al. [13] and van Herk et al. [14] were used to calculate the appropriate margin for PTV based on systematic SD (∑) and random SD (σ). Margins were calculated considering both Δ(inter) and Δ(intra). The total ∑ and σ were calculated according to the following equations:

2 = (∑ of Δ(inter))2 + (∑ of Δ(intra))2

σ2 = (σ of Δ(inter))2 + (σ of Δ(intra))2

Margin recipes were follows:

Stroom et al.’s [13] formula = 2∑ + 0.7σ

van Herk et al.’s [14] formula = 2.5∑ + 0.7σ

Results

Patient characteristics

Twenty-two patients were enrolled. Consequently, 678 fractions with 39 simulations were analysed. The patient characteristics are summarized in Table 1. Two patients (patients numbered 18 and 22) discontinued treatment due to sepsis and patient refusal. During the course of RT, 15 patients lost weight, while 6 patients gained weight. At the end of RT, the average weight changes compared to the start of RT was -2.1±2.7 kg (range, -7.4 to 2 kg).

Table 1. Patient characteristics.

No. Sex Age Primary tumour site BW before RT(kg) ΔBW during RT (kg) Total dose (cGy) Fr.
1 M 76 Tongue 53 0.7 6000 30
2 M 80 Parotid gland 53.9 0.4 6000 30
3 M 63 Oropharynx 62.4 1.6 5040 28
4 M 73 Right retromolar trigone 76.3 -6.4 7000 35
5 M 65 UPMN (Left level IV-V) 46.5 -1.8 6000 30
6 M 53 Floor of Mouth 69.2 -1.7 6000 30
7 M 79 Hypopharynx 59.7 -3.7 7000 35
8 M 64 Glottis 57 -3.6 6600 33
9 M 72 Hypopharynx 59.5 -7.4 7000 35
10 M 61 Subglottis 66 -6 7000 35
11 M 58 Hypopharynx 54.8 -3.8 6600 33
12 M 57 Submandibular gland 53 2 6600 33
13 F 59 Supraglottis 60 -1 6600 33
14 M 69 Tonsil 69.8 0.4 6000 30
15 F 52 Nasopharynx 59 -1 7000 35
16 M 54 Larynx 64 -3 7000 35
17 M 49 Soft palate 72 1 7000 35
18 M 57 Hypopharynx 64 -3 3800 19
19 M 55 Tonsil 61.3 -5.6 7000 35
20 M 73 Supraglottis 66 -2.5 6600 33
21 M 31 Parotid gland 70 -2 6000 30
22 M 66 Supraglottis 44 0 1200 6

Abbreviations: No., registration number; BW, body weight; ΔBW, BW variation; RT, radiotherapy; Fr., fractionation; UPMN, unknown primary metastatic lymph node

ΔBW and ΔBV

Of the 678 fractions, the ΔBW of 485 fractions (71.5%) and ΔBV of 647 fractions (95.4%) were analysable. The average ΔBW and ΔBV of each fraction was -0.43±1.90 kg (range, -7.3 to 5.0 kg) and -24.34±69.0 cc (range, -247.15 to 214.88 cc), and there was significant correlation between ΔBW and ΔBV (Fig 4, Pearson correlation coefficient (PCC) = 0.291, p<0.001). The BW and BV of each fraction were increased in 183 (37.7% of analysable fractions) and 266 (41.1%) fractions, while they were decreased in 221 (45.6%) and 374 (57.8%) fractions, respectively.

Fig 4. Correlations between body weight variations and body volume variations.

Fig 4

In this study, 6 of the 22 enrolled patients attached with bite block. As the use of bite block may introduce potential bias, we performed additional analyses comparing these patients to those who did not attach with bite block. Because the Kolmogorov-Smirnov test revealed that the data for ΔBV, ΔBW, and Δ (intra) and Δ (inter) were not normally distributed among patients who used bite block (p <0.05), the Mann-Whitney U nonparametric test was used for these variables. When bite block was used, ΔBW was -0.15 ± 1.99 kg; when bite block was not used, ΔBW was -0.6 ± 1.83 kg. Weight loss was greater in patients who did not use bite block (p = 0.001). However, there was no significant difference in ΔBV between patients who used or did not use bite block (-12.2 ± 57.46 cc versus -29.26 ± 72.67 cc, p = 0.072).

Δ(inter) and Δ(intra)

Descriptive statistics of Δ(inter) and Δ(intra) are shown in Table 2. Among the 678 fractions, Δ(inter) and Δ(intra) were analysable in 677 fractions (99.9%) and 669 fractions (98.7%), respectively. The 3D vectors, which include variations in three directions, were 3.79 ± 2.04 mm (range, 0.28 to 23.80 mm) and 1.14 ± 0.70 mm (range, 0.01 to 5.66 mm) in Δ3D(inter) and Δ3D(intra), respectively.

Table 2. Descriptive statistics of inter- and intra-fractional variations.

Average ± SD range Average ±SD range
(by absolute value)
Inter-fractional variation ΔRL (mm) 0.38 ± 1.73 -7.99 to 12.19 1.32 ± 1.19 0 to 12.19
ΔSI (mm) -1.02 ± 2.22 -5.53 to 23.75 1.82 ± 1.63 0 to 23.75
ΔAP (mm) -2.19 ± 2.16 -14.4 to 15.85 2.49 ± 1.80 0 to 15.85
Δpitch (°) -0.62 ± 0.96 -4.4 to 2.4 0.87 ± 0.74 0 to 4.4
Δroll (°) 0.03 ± 1.30 -5.6 to 5.8 0.93 ± 0.91 0 to 5.8
Δyaw (°) -0.36 ± 1.02 -3.7 to 2.6 0.82 ± 0.71 0 to 3.7
Δ3D (mm) 3.79 ± 2.04 0.28 to 23.80
Intra-fractional variation ΔRL (mm) 0.01 ± 0.76 -2.89 to 2.44 0.56 ± 0.51 0 to 2.89
ΔSI (mm) -0.07 ± 0.64 -2.79 to 2.55 0.48 ± 0.42 0 to 2.79
ΔAP (mm) -0.02 ± 0.90 -4.74 to 2.99 0.67 ± 0.60 0 to 4.74
Δpitch (°) -0.07 ± 0.55 -2.7 to 1.6 0.40 ± 0.40 0 to 2.7
Δroll (°) 0.05 ± 0.77 -4.2 to 2.9 0.52 ± 0.57 0 to 4.2
Δyaw (°) 0.03 ± 0.49 -2.1 to 3.0 0.35 ± 0.35 0 to 3.0
Δ3D (mm) 1.14 ± 0.70 0.01 to 5.66

Abbreviations: SD, standard deviation; RL, right-left; SI, superior-inferior; AP, anterior-posterior; 3D, three dimensional

Correlations between Δ(inter) or Δ(intra) and ΔBW or ΔBV

The correlations between ΔBW or ΔBV and Δ(inter) or Δ(intra) are summarized in Tables 36. The correlations were significant (p<0.05 and PCC≥0.1 or ≤-0.1) for ΔBW-ΔRL(inter), ΔBW-ΔAP(inter), ΔBW-Δpitch(inter), ΔBV-Δpitch(inter), ΔBW-ΔAP(intra), ΔBW-Δpitch(intra), ΔBW-Δ3D(intra), ΔBV-Δpitch(intra), and ΔBV-Δroll(intra). The PCC between the ΔBW and the ΔAP(intra) was 0.237.

Table 3. Correlations between body weight or body volume variations and inter-fractional variations.

ΔRL(mm) ΔSI(mm) ΔAP(mm) Δpitch(°) Δroll(°) Δyaw(°) Δ3D(mm)
Body weight variations rho 0.166 -0.027 -0.157 -0.195 -0.019 -0.030 -0.026
p 0.000 0.547 0.001 0.000 0.677 0.508 0.569
N 484 484 484 484 484 484 484
Body volume variations rho 0.018 0.038 -0.041 -0.102 0.011 -0.052 0.062
p 0.652 0.335 0.304 0.009 0.783 0.190 0.116
N 646 646 646 646 646 646 646

Abbreviations: ΔRL, variation of right-left; ΔSI, variation of superior-inferior; ΔAP, variation of anterior-posterior; Δpitch, variation of pitch; Δroll, variation of roll; Δyaw, variation of yaw; 3D, three dimensional

Table 6. Correlations between body weight or body volume variations and absolute value of intra-fractional variations.

Absolute value ΔRL(mm) ΔSI(mm) ΔAP(mm) Δpitch(°) Δroll(°) Δyaw(°) Δ3D(mm)
Body weight variations rho -0.110 -0.039 -0.137 -0.027 -0.145 -0.080 -0.156
p 0.016 0.394 0.003 0.558 0.002 0.079 0.001
N 479 479 479 479 479 479 479
Body volume variations rho -0.108 -0.190 -0.081 -0.146 -0.033 -0.117 -0.189
p 0.006 0.000 0.040 0.000 0.405 0.003 0.000
N 635 635 635 635 635 635 635

Abbreviations: ΔRL, variation of right-left; ΔSI, variation of superior-inferior; ΔAP, variation of anterior-posterior; Δpitch, variation of pitch; Δroll, variation of roll; Δyaw, variation of yaw; 3D, three dimensional

Table 4. Correlations between body weight or body volume variations and intra-fractional variations.

ΔRL(mm) ΔSI(mm) ΔAP(mm) Δpitch(°) Δroll(°) Δyaw(°) Δ3D(mm)
Body weight variations rho 0.020 0.074 0.237 0.164 0.015 0.057 -0.156
p 0.660 0.105 0.000 0.000 0.743 0.213 0.001
N 479 0.479 479 479 479 479 479
Body volume variations rho -0.043 0.050 0.035 0.135 -0.101 0.106 -0.189
p 0.284 0.209 0.374 0.001 0.011 0.008 0.000
N 635 635 635 635 635 635 635

Abbreviations: ΔRL, variation of right-left; ΔSI, variation of superior-inferior; ΔAP, variation of anterior-posterior; Δpitch, variation of pitch; Δroll, variation of roll; Δyaw, variation of yaw; 3D, three dimensional

Table 5. Correlations between body weight or body volume variations and absolute value of inter-fractional variations.

Absolute value ΔRL(mm) ΔSI(mm) ΔAP(mm) Δpitch(°) Δroll(°) Δyaw(°) Δ3D(mm)
Body weight variations rho -0.012 -0.111 0.053 -0.072 -0.028 -0.069 -0.026
p 0.792 0.015 0.248 0.111 0.546 0.131 0.569
N 484 484 484 484 484 484 484
Body volume variations rho -0.006 0.067 0.073 0.089 -0.080 0.078 0.062
p 0.879 0.088 0.066 0.024 0.041 0.048 0.116
N 646 646 646 646 646 646 646

Abbreviations: ΔRL, variation of right-left; ΔSI, variation of superior-inferior; ΔAP, variation of anterior-posterior; Δpitch, variation of pitch; Δroll, variation of roll; Δyaw, variation of yaw; 3D, three dimensional

Regarding the absolute values of Δ(inter) or Δ(intra), correlations were significant for ΔBW-ΔSI(inter), ΔBW-ΔRL(intra), ΔBW-ΔAP(intra), ΔBW-Δroll(intra), ΔBW-Δ3D(intra), ΔBV-ΔRL(intra), ΔBV-ΔSI(intra), ΔBV-Δpitch(intra), ΔBV-Δyaw(intra), and ΔBV-Δ3D(intra).

ROC analysis

ROC analysis based on Δ(inter) ≥3 mm and Δ(intra) ≥2 mm of RL, AP, SI, 3D vector, and any directions (when any one of the RL, SI, or AP was outside the specified tolerance) was performed (Table 7). Significance was observed at ΔAP(intra)-decrease of ΔBW (area under the curve (AUC) = 0.694), Δ3D(intra)-decrease of ΔBW (AUC = 0.646), any direction of Δ(intra)-decrease of ΔBV (AUC = 0.707), Δ3D(intra)-decrease of ΔBV (AUC = 0.639), and any direction of Δ(intra)-decrease of ΔBV (AUC = 0.694) (Fig 5A–5C).

Table 7. Results of receiver operating characteristic analysis between decrease of body weight or volume and inter- (≥3 mm) or intra-fractional (≥ 2 mm) variations.

Asymptotic 95% CI
AUC Asymptotic significance Lower bound Upper bound
Δ(inter)—decrease of ΔBW RL 0.558 0.228 0.468 0.649
SI 0.513 0.670 0.449 0.578
AP 0.442 0.042 0.381 0.503
3D 0.469 0.252 0.417 0.520
Any direction 0.491 0.737 0.439 0.544
Δ(inter)—decrease of ΔBV RL 0.541 0.400 0.437 0.645
SI 0.429 0.021 0.366 0.492
AP 0.425 0.009 0.369 0.482
3D 0.452 0.078 0.399 0.505
Any direction 0.435 0.015 0.384 0.487
Δ(intra)—decrease of ΔBW RL 0.668 0.069 0.490 0.846
SI 0.459 0.886 0.358 0.559
AP 0.694 0.007 0.557 0.831
3D 0.646 0.001 0.559 0.733
Any direction 0.659 0.006 0.548 0.771
Δ(intra)—decrease of ΔBV RL 0.663 0.077 0.517 0.810
SI 0.970 0.104 0.955 0.986
AP 0.707 0.004 0.579 0.835
3D 0.639 0.002 0.547 0.731
Any direction 0.694 0.001 0.592 0.796

Abbreviations: AUC, area under receiver operating characteristic curve; CI, confidence interval; RL, right-left; SI, superior-inferior; AP, anterior-posterior; 3D, three dimensional; Δ(inter), inter-fractional variation; Δ(intra), intra-fractional variation; ΔBW, variation of body weight; ΔBW, variation of body volume

Fig 5.

Fig 5

(A) Receiver operating characteristic curve of intra-fractional variations (≥2 mm) of anterior-posterior and decrease of body weight or volume. (B) Receiver operating characteristic curve of intra-fractional variations (≥2 mm) of three-dimensional vector and decrease of body weight or volume. (C) Receiver operating characteristic curve of intra-fractional variations (≥2 mm) of any directions and decrease of body weight or volume.

Comparison of 1 kg group of ΔBW

A box plot of the ΔAP(intra), Δ3D(intra), and Δpitch(intra) grouping in groups of 1 kg of ΔBW are shown in Fig 6A–6C. These graphs showed larger variations in patients with weight loss of more than 3 kg. No profound differences were noted in other directions of Δ(intra) and all directions of Δ(inter).

Fig 6.

Fig 6

(A) Box plot of intra-fractional variation of anterior-posterior direction per body weight variation group of 1 kg. (B) Box plot of intra-fractional variation of pitch per body weight variation group of 1 kg. (C) Box plot of intra-fractional variation of three-dimensional vector per body weight variation group of 1 kg.

Optimal margins for the PTV from the CTV

Table 8 summarizes the optimal margins for the PTV based on systematic SD (∑) and random SD (σ) as previously proposed [13,14]. Based on Stroom’s formula, the calculated margins considering Δ(inter) ranged from 2.87 mm to 3.99 mm, and the margins considering both Δ(inter) and Δ(intra) ranged from 3.04 mm to 4.19 mm. Based on van Herk’s formula, the calculated margins are 3.5–4.88 mm and 3.7–5.12 mm, respectively.

Table 8. Optimal margins for PTV considering both inter- and intra-fractional variations.

Recipe Margins considering intra-fractional variations only Margins considering both inter- and intra-fractional variations
RL (mm) SI (mm) AP (mm) RL (mm) SI (mm) AP (mm)
2∑ + 0.7σ [13] 2.87 3.66 3.99 3.04 3.75 4.19
2∑ + 0.7σ [14] 3.5 4.41 4.88 3.7 4.52 5.12

Abbreviations: RL, right-left; SI, superior-inferior; AP, anterior-posterior; ∑, standard deviation of systematic errors; σ, standard deviation of random errors

Repeated simulation due to the post-treatment ExacTrac exceeding 3 mm

Repeated simulation was performed when the post-treatment ExacTrac exceeded 3 mm in RL, SI, or AP. Patient number of 8 and 11 required repeated simulations after the 15th and 17th fractions, respectively (Fig 7A and 7B). For both of these patients, there was no planned repeat simulation.

Fig 7.

Fig 7

(A) Intra-fractional error of patient number eight. Simulation had to be repeated in this patient after the 15th fraction. The average and standard deviation of three-dimensional intra-fractional variations before and after repeated simulation were 1.37±0.84 mm and 1.19±0.51 mm, respectively. (B) Intra-fractional error of patient number 11. Simulation had to be repeated in this patient after the 17th fraction. The average and standard deviation of three-dimensional intra-fractional variations before and after repeated simulation were 1.73 ± 1.02 mm and 1.46 ± 0.68 mm, respectively.

Discussion

Optimal margins for the PTV from the CTV

In this study, the ExacTrac system and CBCT were used to calculate the optimal margins from the CTV to the PTV. However, Qi et al.[15] have reported that daily random setup errors and the CTV-to-PTV margins for treatment of head-and-neck cancer were highly affected by IGRT modalities and image quality. To identify the differences between image systems, in our previous study [16], we reported that the clinical setup discrepancy between the ExacTrac system and the CBCT for the intracranial stereotactic radiosurgery was <1.01 mm and <0.82° for online matching.

Assessment of intra-fractional motion with pre- and post-kV imaging as a surrogate of intra-fractional motion is an important issue. However, many studies have previously used multi-modalities such as computed tomography (CT), CBCT, magnetic resonance imaging (MRI), and kV images as surrogates of intra- or intra-fractional motion [412]. These studies have assumed that the evaluation of motion trajectory at specific time points, such as before and after treatment, represents inter-or intra setup variation in radiotherapy. Chan et al. [17] has pointed out that continuous fluoroscopic imaging can trace the tumour motion trajectory throughout the radiotherapy treatment, but the patient may receive additional undesired radiation dose. Therefore, we assumed that the kV images before and after treatment sufficiently represented intra-fractional variations.

The criteria for optimal margins in PTV have not been established. In general, the Radiation Therapy Oncology Group protocols recommend a minimum of 5 mm margin around the CTV in all dimensions for HNC patients who did not undergo IGRT [18]. The calculated margins of our study considering only Δ(inter) for the PTV based on Stroom’s and van Herk’s formula [13,14] are generally consistent with those of previous studies. In previous studies, the optimal margins calculated based on van Herk’s formula were 3.4–3.8 mm, 3.8–4.8 mm, and 3.7–4.4 mm in the RL, SI, and AP directions, respectively [1921] (Table 9). Considering Δ(inter) only, a 5 mm margin for PTV seems to be sufficient in all dimensions.

Table 9. Comparisons of calculated margins for planning target volumes with those of previous studies considering inter-fractional variations.

Author Image guide method Margin recipe Calculated margin (mm)
RL SI AP
Dionisi et al. [19] CBCT 2.5∑ + 0.7σ 3.48 4.08 4.33
Dzierma et al. [20] CBCT 2∑ + 0.7σ 3.3 3.3 3.5
2.5∑ + 0.7σ 3.8 3.8 4.0
Gupta et al. [21] EPID 2∑ + 0.7σ 3.34 4.14 3.28
2.5∑ + 0.7σ 3.76 4.74 3.76
This study ExacTrac 2∑ + 0.7σ 2.87 3.66 3.99
2.5∑ + 0.7σ 3.50 4.41 4.88

Abbreviation: RL, right-left; SI, superior-inferior; AP, anterior-posterior; CBCT, cone beam computed tomography; EPID, electronic portal imaging device

The calculated margins based on van Herk’s formula considering both Δ(inter) and Δ(intra) were analogous to the results obtained by Cacicedo et al. [22] in the RL (3.7–4.2 mm) and SI (3.9–4.5 mm) directions, but there was a difference of approximately 1 mm in the AP direction (4.1 mm in the study of Cacicedo et al. [22] vs 5.12 mm in our study, Table 10). In our study, ExacTrac was used, while a previous study [22] measured the error using only the AP and lateral field via an electronic portal imaging device. ExacTrac provides 6D information on the error, which is calibrated using the 6D couch, allowing for more accurate measurements of Δ(inter) and Δ(intra).

Table 10. Comparisons of calculated margins for planning target volumes with those of previous studies considering both inter- and intra-fractional variations.

Author Image guide method Margin recipe Calculated margin (mm)
RL SI AP
Cacicedo et al.[22] EPID 2∑ + 0.7σ 3.6 3.3 3.5
2.5∑ + 0.7σ 4.2 3.9 4.1
This study ExacTrac 2∑ + 0.7σ 3.04 3.75 4.19
2.5∑ + 0.7σ 3.70 4.52 5.12

Abbreviation: RL, right-left; SI, superior-inferior; AP, anterior-posterior; EPID, electronic portal imaging device

Impact of ΔBW or ΔBV and set-up error (Δ(inter) or Δ(intra))

The correlations between ΔBW and Δ(inter) were significant in several studies [23,24], although some studies reported contrasting results [25,26]. Hou et al. [23] reported that patients with nasopharyngeal cancer with weight loss of >5% had significantly larger ΔAP(inter). Zia et al. [24] found that weight loss was associated with ΔLR(inter). In our study, ΔRL(inter), ΔAP(inter), and Δpitch(inter) were correlated with ΔBW, and Δpitch(inter) was correlated with ΔBV (PCC>0.1 or PCC<-0.1). To ignore the offset due to the direction of error, we analysed the absolute value of Δ(inter). Then, ΔSI(inter) was correlated with absolute value of ΔBW (PCC = -0.111), but no Δ(inter) was correlated with the absolute value of ΔBV.

It is important that Δ(intra) is not neglected. Cacicedo et al. [22] reported that systemic and random Δ(intra) were 0.65–1.11 mm and 1.13–1.16 mm at 3 mm action level, while systemic and random Δ(inter) were 0.77–1.42 mm and 1–1.31 mm, respectively. Gurney-Champion et al. [5] assessed Δ(intra) based on magnetic resonance images, and systemic and random Δ(intra) were <1.4 mm and <2.1 mm 95% of the time. In our study, the average Δ3D was 1.14 mm ± 0.70 (range, 0.01 to 5.66 mm). However, to the best of our knowledge, no study has analysed the relationship between ΔBW or ΔBV and Δ(intra). In our study, ΔAP(intra), Δpitch(intra), and Δ3D(intra) were weakly correlated with ΔBW. Further, Δpitch(intra), Δroll(intra), Δyaw(intra), and Δ3D(intra) were weakly correlated with ΔBV (PCC>0.1 or PCC<-0.1). When compared with the absolute value, ΔRL(intra), ΔAP(intra), Δroll(intra), and Δ3D(intra) were weakly correlated with ΔBW. In addition, ΔRL(intra), ΔSI(intra), Δpitch(intra), Δyaw(intra), and Δ3D(intra) were also correlated with ΔBV. In general, Δ(intra) was more strongly associated with ΔBW or ΔBV than Δ(inter). ROC analysis showed similar results, that is, Δ(intra) was correlated with ΔBW or ΔBV, while Δ(inter) was not. These results indicate the need for further studies on the relationship between ΔBW or ΔBV and Δ(intra) for accurate RT for patients with HNC.

In addition, a box plot of ΔAP(intra) grouping in groups of 1 kg suggests that weight loss >3 kg may result in larger Δ(intra). This result suggests that repeated simulation may be needed when the weight loss is over 3 kg. Because Δ(intra) is an important issue in the RT for HNC patients, further studies should be considered. Recently, Navran et al.[27] reported that reducing the CTV-PTV margin from 5 mm to 3 mm, combined with daily CBCT-guided VMAT, reduced the radiation-related toxicity. Thus, in order to reduce the margin, it is important to maintain body weight during radiotherapy.

The absorbed dose of the image guidance system by multi modalities should be confirmed in image registration and setup protocol. Because single verification with X-ray tube 1 and 2 with ExacTrac system is 1 mSv [12], the overall absorbed dose for the ExacTrac system is 4 mSv with 2mSv for inter-fractional variation, and 2mSv for intra-fractional variations. This dose is lower than the dose of CBCT (14 mSv).

Study limitations

First, BV measurement using CBCT has some uncertainties. Compared to conventional CT, distinct artefacts present in CBCT could impact BV measurement, although we believe this risk disappears due to the large number of fractions. Second, because BW measurement and CBCT were not performed on all patients, only 71.5% of ΔBW and 95.4% of ΔBV were analysable. In addition, pre-treatment ExacTrac was not performed in one fraction because of a mechanical problem. Moreover, post-treatment ExacTrac was missed in 8 of the 678 fractions. Third, weight loss was smaller than expected. The average ΔBW was -0.43±1.90 kg in all fractions, and ΔBW was increased in 37.7% of the analysable fractions. Also, we performed repeated simulation when the post-treatment ExacTrac showed over 3 mm of variation which reflect Δ(intra). Thus, excessive Δ(intra) was suppressed. As such, it was difficult to observe any significant set-up error.

Conclusions

The PTV margins of 6 mm for AP direction and 5 mm for the other directions were needed to include 95% of both inter- and intra-fractional set-up variations. Further, BW and BV were correlated with set-up variations. Specifically, intra-fractional variations were positively correlated with changes in BW or BV. Therefore, assessments of BW and BV should be considered for accurate IMRT in patients with HNC.

Acknowledgments

This work was supported by the 2018 Yeungnam University Research Grant.

Data Availability

All relevant data are within the manuscript.

Funding Statement

This work was supported by the Yeungnam University Research Grant. The funder had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.

References

  • 1.Haddad RI, Shin DM (2008) Recent advances in head and neck cancer. New England Journal of Medicine 359: 1143–1154. 10.1056/NEJMra0707975 [DOI] [PubMed] [Google Scholar]
  • 2.Nutting CM, Morden JP, Harrington KJ, Urbano TG, Bhide SA, et al. (2011) Parotid-sparing intensity modulated versus conventional radiotherapy in head and neck cancer (PARSPORT): a phase 3 multicentre randomised controlled trial. The lancet oncology 12: 127–136. 10.1016/S1470-2045(10)70290-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Mendenhall WM, Amdur RJ, Palta JR (2006) Intensity-modulated radiotherapy in the standard management of head and neck cancer: promises and pitfalls. Journal of clinical oncology 24: 2618–2623. 10.1200/JCO.2005.04.7225 [DOI] [PubMed] [Google Scholar]
  • 4.Lu H, Lin H, Feng G, Chen J, Shu L, et al. (2012) Interfractional and intrafractional errors assessed by daily cone-beam computed tomography in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy: a prospective study. J Radiat Res 53: 954–960. 10.1093/jrr/rrs041 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Gurney-Champion OJ, McQuaid D, Dunlop A, Wong KH, Welsh LC, et al. (2018) MRI-based Assessment of 3D Intrafractional Motion of Head and Neck Cancer for Radiation Therapy. Int J Radiat Oncol Biol Phys 100: 306–316. 10.1016/j.ijrobp.2017.10.016 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Bruijnen T, Stemkens B, Terhaard CHJ, Lagendijk JJW, Raaijmakers CPJ, et al. (2018) Intrafraction motion quantification and planning target volume margin determination of head-and-neck tumors using cine magnetic resonance imaging. Radiother Oncol. [DOI] [PubMed] [Google Scholar]
  • 7.Chen C, Fei Z, Chen L, Bai P, Lin X, et al. (2014) Will weight loss cause significant dosimetric changes of target volumes and organs at risk in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy? Med Dosim 39: 34–37. 10.1016/j.meddos.2013.09.002 [DOI] [PubMed] [Google Scholar]
  • 8.Chamchod S, Fuller CD, Mohamed AS, Grossberg A, Messer JA, et al. (2016) Quantitative body mass characterization before and after head and neck cancer radiotherapy: A challenge of height-weight formulae using computed tomography measurement. Oral Oncol 61: 62–69. 10.1016/j.oraloncology.2016.08.012 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Takao S, Tadano S, Taguchi H, Yasuda K, Onimaru R, et al. (2011) Accurate analysis of the change in volume, location, and shape of metastatic cervical lymph nodes during radiotherapy. Int J Radiat Oncol Biol Phys 81: 871–879. 10.1016/j.ijrobp.2010.11.078 [DOI] [PubMed] [Google Scholar]
  • 10.Huang H, Lu H, Feng G, Jiang H, Chen J, et al. (2015) Determining appropriate timing of adaptive radiation therapy for nasopharyngeal carcinoma during intensity-modulated radiation therapy. Radiat Oncol 10: 192 10.1186/s13014-015-0498-1 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Lai YL, Yang SN, Liang JA, Wang YC, Yu CY, et al. (2014) Impact of body-mass factors on setup displacement in patients with head and neck cancer treated with radiotherapy using daily on-line image guidance. Radiat Oncol 9: 19 10.1186/1748-717X-9-19 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Oh SA, Yea JW, Kang MK, Park JW, Kim SK (2016) Analysis of the setup uncertainty and margin of the daily exactrac 6D image guide system for patients with brain tumors. PloS one 11: e0151709 10.1371/journal.pone.0151709 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Stroom JC, de Boer HC, Huizenga H, Visser AG (1999) Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability. Int J Radiat Oncol Biol Phys 43: 905–919. [DOI] [PubMed] [Google Scholar]
  • 14.van Herk M, Remeijer P, Rasch C, Lebesque JV (2000) The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys 47: 1121–1135. [DOI] [PubMed] [Google Scholar]
  • 15.Qi XS, Hu AY, Lee SP, Lee P, DeMarco J, et al. (2013) Assessment of interfraction patient setup for head-and-neck cancer intensity modulated radiation therapy using multiple computed tomography-based image guidance. International Journal of Radiation Oncology* Biology* Physics 86: 432–439. [DOI] [PubMed] [Google Scholar]
  • 16.Oh SA, Park JW, Yea JW, Kim SK (2017) Evaluations of the setup discrepancy between BrainLAB 6D ExacTrac and cone-beam computed tomography used with the imaging guidance system Novalis-Tx for intracranial stereotactic radiosurgery. PloS one 12: e0177798 10.1371/journal.pone.0177798 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Chan MK, Kwong DL, Tam E, Tong A, Ng SC (2013) Quantifying variability of intrafractional target motion in stereotactic body radiotherapy for lung cancers. Journal of applied clinical medical physics 14: 140–152. 10.1120/jacmp.v14i5.4319 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.RTOG (2018) Protocol Table.
  • 19.Dionisi F, Palazzi MF, Bracco F, Brambilla MG, Carbonini C, et al. (2013) Set-up errors and planning target volume margins in head and neck cancer radiotherapy: a clinical study of image guidance with on-line cone-beam computed tomography. Int J Clin Oncol 18: 418–427. 10.1007/s10147-012-0395-7 [DOI] [PubMed] [Google Scholar]
  • 20.Dzierma Y, Beyhs M, Palm J, Niewald M, Bell K, et al. (2015) Set-up errors and planning margins in planar and CBCT image-guided radiotherapy using three different imaging systems: A clinical study for prostate and head-and-neck cancer. Phys Med 31: 1055–1059. 10.1016/j.ejmp.2015.09.002 [DOI] [PubMed] [Google Scholar]
  • 21.Gupta T, Chopra S, Kadam A, Agarwal JP, Devi PR, et al. (2007) Assessment of three-dimensional set-up errors in conventional head and neck radiotherapy using electronic portal imaging device. Radiat Oncol 2: 44 10.1186/1748-717X-2-44 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Cacicedo J, Perez JF, Ortiz de Zarate R, del Hoyo O, Casquero F, et al. (2015) A prospective analysis of inter- and intrafractional errors to calculate CTV to PTV margins in head and neck patients. Clin Transl Oncol 17: 113–120. 10.1007/s12094-014-1200-z [DOI] [PubMed] [Google Scholar]
  • 23.Hou WH, Wang CW, Tsai CL, Hsu FM, Cheng JC (2016) The ratio of weight loss to planning target volume significantly impacts setup errors in nasopharyngeal cancer patients undergoing helical tomotherapy with daily megavoltage computed tomography. Radiol Oncol 50: 427–432. 10.1515/raon-2016-0047 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Zia SY, Smith W, Ozbek U, Mirza A, Sheu R, et al. (2016) The impact of weight loss on setup accuracy for head and neck cancer patients in the era of image guided radiation therapy. Journal of Radiation Oncology 5: 359–362. [Google Scholar]
  • 25.Johansen J, Bertelsen A, Hansen CR, Westberg J, Hansen O, et al. (2008) Set-up errors in patients undergoing image guided radiation treatment. Relationship to body mass index and weight loss. Acta Oncol 47: 1454–1458. 10.1080/02841860802256517 [DOI] [PubMed] [Google Scholar]
  • 26.De Bari B, Ait Erraisse M, Chekrine T, Rabilloud M, Shakir Shakir I, et al. (2012) Does weight loss predict accuracy of setup in head and neck cancer patients treated with Intensity-Modulated Radiation Therapy? Radiol Med 117: 885–891. 10.1007/s11547-011-0765-7 [DOI] [PubMed] [Google Scholar]
  • 27.Navran A, Heemsbergen W, Janssen T, Hamming-Vrieze O, Jonker M, et al. (2018) The impact of margin reduction on outcome and toxicity in head and neck cancer patients treated with image-guided volumetric modulated arc therapy (VMAT). Radiotherapy and Oncology. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

All relevant data are within the manuscript.


Articles from PLoS ONE are provided here courtesy of PLOS

RESOURCES