Skip to main content
PLOS One logoLink to PLOS One
. 2019 May 22;14(5):e0217290. doi: 10.1371/journal.pone.0217290

Development of a miniaturized protein microarray as a new serological IgG screening test for zoonotic agents and production diseases in pigs

Katharina Loreck 1,*, Sylvia Mitrenga 1, Diana Meemken 2, Regina Heinze 3, Annett Reissig 4,5, Elke Mueller 4,5, Ralf Ehricht 4,5, Claudia Engemann 6, Matthias Greiner 1,7
Editor: Baochuan Lin8
PMCID: PMC6530865  PMID: 31116794

Abstract

In order to monitor the occurrence of zoonotic agents in pig herds as well as to improve herd health management, the development of new cost-effective diagnostic methods for pigs is necessary. In this study, a protein microarray-based assay for the simultaneous detection of immunoglobulin G (IgG) antibodies against different zoonotic agents and pathogens causing production diseases in pigs was developed. Therefore, antigens of ten different important swine pathogens (Toxoplasma gondii, Yersinia enterocolitica, Salmonella spp., Trichinella spp., Mycobacterium avium, Hepatitis E virus, Mycoplasma hyopneumoniae, Actinobacillus pleuropneumoniae, the porcine reproductive and respiratory syndrome virus, Influenza A virus) were spotted and covalently immobilized as ‘antigen-spots’ on microarray chips in order to test pig serum for the occurrence of antibodies. Pig serum was sampled at three German abattoirs and ELISA tests for the different pathogens were conducted with the purpose of creating a panel of reference samples for microarray analysis. To evaluate the accuracy of the antigens on the microarray, receiver operating characteristic (ROC) curve analysis using the ELISA test results as reference was performed for the different antigens. High area under curve values were achieved for the antigens of two zoonotic agents: Toxoplasma gondii (0.91), Yersinia enterocolitica (0.97) and for three production diseases: Actinobacillus pleuropneumoniae (0.77), Mycoplasma hyopneumoniae (0.94) and the porcine reproductive and respiratory syndrome virus (0.87). With the help of the newly developed microarray assay, collecting data on the occurrence of antibodies against zoonotic agents and production diseases in pig herds could be minimized to one measurement, resulting in an efficient screening test.

Introduction

Due to the frequent occurrence of zoonotic agents in pig herds at slaughter, fast and economic monitoring tools to control these pathogens are in high demand in pork production [1, 2]. In 2011, the European Food Safety Authority (EFSA) identified Salmonella spp., Yersinia (Y.) enterocolitica, Toxoplasma (T.) gondii and Trichinella spp. as the most relevant biological public health hazards in the context of meat inspection of swine [3]. These zoonotic agents as well as Mycobacterium (M.) avium [4] and Hepatitis E virus [5] from pig carcasses constitute a danger to human health, but can usually not be detected by the official post-mortem meat inspection due to the lack of macroscopically visible carcass alterations. As a consequence, the porcine meat inspection is limited to a visual inspection in accordance with Regulation (EC) No. 219/2014 and increasing importance is given to the so-called ‘food chain information’ (FCI). Results of samples taken within the scope of monitoring and controlling zoonotic agents should be included in the FCI in accordance with Regulation (EC) No. 853/2004. So far, 50% of the member states of the European Union have implemented the transmission of monitoring data via the FCI in their national Salmonella monitoring program [6]. However, a cost-efficient diagnostic method suitable for routine testing to accomplish a broad monitoring for multiple pathogens is missing.

Apart from protecting human health, the European food safety policy also pursues the aim of continuous improvement of animal health and animal welfare [7]. The major challenge in maintaining a good health status in pig herds is the occurrence of production diseases. Especially production diseases caused by respiratory pathogens are difficult to control since they are part of a multifactorial process [8, 9]. Actinobacillus (A.) pleuropneumoniae, Mycoplasma (M.) hyopneumoniae, the swine influenza virus and the porcine reproductive and respiratory syndrome virus (PRRSV) are known to cause respiratory diseases in pigs. For the PRRS virus, two different genotypes, Type 1, mainly comprised of viruses from Europe (EU genotype), and Type 2, mainly comprised of viruses from North America (NA genotype) are circulating globally [10]. High herd seroprevalences of all four pathogens are associated with the frequent occurrence of pleuritis and pulmonary lesions at slaughter [11, 12]. A serological monitoring of these pathogens could be useful for herd health management [1].

The most common diagnostic methods for detecting zoonotic agents and respiratory diseases in pigs are bacteriological cultivation, virus isolation, molecular assays based on PCR, as well as serological methods (for IgG and IgM) such as the enzyme-linked immunosorbent assay (ELISA). However, for monitoring different pathogens in pig herds simultaneously, the required sample throughput would be too high with these methods. In order to save costs and analysis time per assay, multi-analyte assays like multiplex PCR assays [13], bead-based Luminex xMap assays [14] and microarray assays [15, 16] were developed in medical research. With regard to applying these methods in pork production, mainly studies concerning the development of multiplex PCRs for the simultaneous detection of porcine viruses have been published [1720]. Moreover, first approaches with bead-based assays for serological detection of T. gondii and Trichinella spp. in pigs were described [21, 22]. The development of a gold nanoparticle-based oligonucleotide microarray for detecting seven porcine viruses [23] and a flow-through chemiluminescence immunochip to detect antibodies against Y. enterocolitica and Hepatitis E virus [24] have been published as well. Regarding the detection of respiratory pathogens in pigs, the development of a microarray for four viruses and four bacteria was described [25]. Nonetheless, assays for the simultaneous detection of antibodies against zoonotic agents that are most interesting for food safety, including viruses, bacteria and parasites, have not been reported. Previous studies on protein microarrays have shown that this method is an effective tool for detecting different antibody patterns [2631].

The objective of this study was therefore to test whether a protein microarray with antigens of six different zoonotic agents (T. gondii, Y. enterocolitica, Salmonella spp., Trichinella spp., M avium, Hepatitis E virus) and four different production diseases (M. hyopneumoniae, A. pleuropneumoniae, PRRSV, Influenza A virus) spotted and covalently immobilized on the microarray surface would allow the simultaneous testing of pigs for the presence of different antibodies. In terms of methodology, this study is linked to a preceding study [30]. In a similar approach, this study investigates the accuracy of antigens on a microarray by using established ELISA tests with comparable antigens as reference tests.

Material and methods

Ethics statement

No animals had to be sacrificed for this study. Blood was sampled from pigs at the abattoir after the regular end of the fattening period. The slaughter process was performed by professional abattoir personnel in accordance with European animal welfare regulations for slaughter. Investigators did not interfere with the slaughter process. The blood sampling took place on the slaughter line when the slaughter process had already been completed. The sampling did not affect the release of the meat for human consumption. The animal research ethics committee of the University of Veterinary Medicine Hannover has prospectively checked the approach and decided that in accordance with the German animal protection law, no authorization to carry out animal experiments is necessary for this study.

Sampling at the abattoir

Blood samples of 184 fattening pigs from 30 different conventional pig herds located in Lower Saxony, Germany were taken between October 2016 and January 2017 at three German abattoirs (Lohne, Garrel, Emstek). Pigs were delivered to the abattoirs at the end of the fattening period. A regular slaughter process, including carbon dioxide stunning and inserting a chest-stick for bleeding, was performed by abattoir personnel. Blood from the brachiocephalic trunk and surrounding vessels was collected at the slaughter line in serum tubes (KABE Labortechnik, Nuembrecht, Germany). Next, collected blood was centrifuged at 2000 rpm for 10 minutes and the serum supernatant was transferred to plastic cups (Eppendorf, Hamburg, Germany) and stored at -80°C until further analysis.

ELISA analysis

The collected serum samples were analyzed with the ELISA tests presented in Table 1. ELISA tests from two different manufacturers were used, which provided the identical antigens from their ordinary ELISA production to produce the microarray. All ELISA tests used in this study are designed to measure IgG antibodies and anti-pig IgG or multi-species conjugates are used in the ELISA test protocols. To keep the level of comparability between ELISA and Microarray antigens at a consistent level for all antigens, the ELISA tests pigtype HEV Ab, pigtype SIV Ab and pigtype Mycobacterium Ab were specially produced for this study. These ELISA tests were validated and checked with reference sera by Indical (Indical Bioscience GmbH, Leipzig, Germany) prior to this study. For all ELISA tests, the cut-off values were set by the ELISA manufacturers. If an intermediate range between positive and negative results was given, the cut-off value was set to the middle of this intermediate range. The ELISA tests were conducted at the accredited service laboratories of the LUFA Nord-West (LUFA Nord-West, Institute for Animal Health, Oldenburg, Germany) and LVL (LVL Lebensmittel- und Veterinärlabor GmbH, Emstek, Germany). For each sample, measured optical densities were corrected by calculating relative OD % from optical density values of positive and negative controls from every ELISA plate.

Table 1. Antigens spotted on the microarray chip and ELISA tests used as reference tests.

Antigens spotted on microarray ELISA tests used as reference tests
Antigen Antigen concentration (μg/μL) Nature of the antigen Antigen manufacturer ELISA manufacturer ELISA test ELISA cut-off
T. gondii 0.1, 0.2 tachyzoite antigen Indical 1 Indical pigtype Toxoplasma Ab 0.3
Trichinella spp. 1:50, 1:20 7 T. spiralis E/S antigen pigtype Trichinella Ab 0.3
Y. entero-colitica mix 0.1, 0.2, 0.3 recombinant antigen pigtype Yersinia Ab 0.3
Y. entero-colitica Yop O:3 0.1, 0.2, 0.5 native antigen Serion 2 pigtype Yersinia Ab 0.3
Hepatitis E virus 0.25, 0.5, 0.75 recombinant antigen Indical pigtype HEV Ab 0.3
M. avium 0.05, 0.1, 0.23 whole cell antigen pigtypeMycobacterium Ab 0.425 8
M. hyo-pneumoniae 1:50, 1:20, 1:10 7 recombinant antigen IDvet 3 IDvet ID Screen Mycoplasma hyopneumoniae Indirect 0.35 8
A. pleuro-pneumoniae 4 1:20, 1:10, 1:5 7 native LPS antigen ID Screen APP Screening Indirect (serotypes 1 through 12) 0.275 8
Influenza A virus 0.05, 0.1, 0.2 recombinant antigen Indical Indical pigtype SIV Ab 0.3
Salmonella spp.
ELISA mix
0.1, 0.2, 0.5, 0.75 LPS antigen pigtype Salmonella Ab 0.3
Salmonella spp.
in-house mix 5
0.1, 0.2, 0.5, 0.75 LPS antigen pigtype Salmonella Ab 0.3
PRRSV
in-house mix 6
0.1, 0.2, 0.5, 0.75 recombinant antigen pigtype PRRSV Ab 0.4

Antigens offered by ELISA manufacturers were spotted on the microarray chip in different concentrations. ELISA tests were used as reference tests. The ELISA cut-off values were set by the ELISA manufacturers.

1 Indical Bioscience GmbH, Leipzig, Germany.

2 Institut Virion/Serion GmbH, Wuerzburg, Germany. For this antigen the Indical ELISA test was used as reference test as no corresponding ELISA test was available.

3 IDvet, Grabels, France.

4 This antigen contains the serotypes 1 to 12 and is similar to the ELISA antigen.

5 This antigen is a mix of four antigens offered by Indical (Salmonella (S.) Enteritidis, S. Typhimurium, S. Cholerasuis, S. Anatum) and was mixed in equal concentrations.

6 This antigen is a mix of two antigens offered by Indical (PRRSV EU genotype, PRRSV NA genotype) and was mixed in equal concentrations.

7 The information concerning the initial antigen concentration could not be shared, which is why different dilutions of the initial antigen solution were spotted.

8 For test interpretation, the cut-off was set to the middle of an intermediate range given by the ELISA manufacturer.

Microarray production and antigen selection

The microarrays used in this study were manufactured by Abbott/Alere Technologies GmbH, Jena, Germany. The ArrayTube platform was chosen, which consists of a 3D-epoxy-modified glass chip (4.36 mm x 4.36 mm) attached to the bottom of a plastic reaction vial. The glass chip accommodates up to 343 antigen probe spots with an average diameter of approximately 120 μm. The spotting process itself was previously described by Ehricht et al. [16]. The coupling is done with an epoxy layer. Epoxyslides with different additives and concentrations were preliminary tested. The selected antigens and the different antigen concentrations spotted on the microarray chip are presented in Table 1. The antigen offered by Serion (Institut Virion/Serion GmbH, Wuerzburg, Germany) is a Yersinia outer protein (Yop) of the serotype O:3, which was produced in a cell culture supernatant. An ELISA test with this antigen is currently not available and could not be produced for this study. Therefore, the ELISA results from the Indical ELISA test were also used as reference for this antigen.

Each antigen was spotted in up to four different concentrations, based on experience from two previous test productions, by adding a spotting buffer (Abbott/Alere Technologies GmbH) to the antigen prior to the spotting process. Apart from the antigens presented in Table 1, purified-pig-IgG (BIOMOL GmbH, Hamburg, Germany) was spotted on each microarray as a control. Moreover, a biotinylated oligonucleotide and a buffer spot were spotted for an internal production control by Abbott/Alere Technologies GmbH. In addition, S. Enteritidis, S. Typhimurium, S. Cholerasuis, S. Anatum, a PRRSV ELISA mix, native-pig-IgM and recombinant protein A/G-HRP were spotted due to technical interest in extending the microarray, but were not analyzed in this study. Every antigen concentration was spotted in quadruplicate. For reasons of space, the A. pleuropneumoniae spot in the dilution 1:10 was only spotted in triplicate and the M. hyopneumoniae spots in the dilution 1:10 and 1:20 were spotted in duplicate. All replicated spots were evenly distributed across the microarray chip. The full layout of the produced microarray is shown in Fig 1.

Fig 1. Layout of the produced microarray chip.

Fig 1

Antigens were spotted in different concentrations (μg/μL). Black squares are metal marks and are necessary for image analysis. 1–3: Hepatitis E virus (1 = 0.75, 2 = 0.5, 3 = 0.25); 4–6: M. avium (4 = 0.23, 5 = 0.1, 6 = 0.05); 7–9: Y. enterocolitica mix (7 = 0.3, 8 = 0.2, 9 = 0.1); 10–12: Influenza A virus (10 = 0.2, 11 = 0.1, 12 = 0.05); 13–16: PRRSV ELISA mix (13 = 0.75, 14 = 0.5, 15 = 0.2, 16 = 0.1); 17–20: PRRSV in-house mix (17 = 0.75, 18 = 0.5, 19 = 0.2, 20 = 0.1); 21–24: Salmonella spp. ELISA mix (21 = 0.75, 22 = 0.5, 23 = 0.2, 24 = 0.1); 25–28: Salmonella spp. in-house mix (25 = 0.75, 26 = 0.5, 27 = 0.2, 28 = 0.1); 29–30: Salmonella Enteritidis (29 = 0.75, 30 = 0.5); 32–33: Salmonella Typhimurium (32 = 0.75, 33 = 0.5); 35–37: Salmonella Cholerasuis (35 = 0.5, 36 = 0.2, 37 = 0.1), 38–40; Salmonella Anatum (38 = 0.5, 39 = 0.2, 40 = 0.1); 41–42: T. gondii (41 = 0.5, 42 = 0.2); 43–44: Trichinella spp. (43 = 1:20, 44 = 1:50); 46–48: A. pleuropneumoniae (46 = 1:5, 47 = 1:10, 48 = 1:20); 49–51: M. hyopneumoniae (49 = 1:10, 50 = 1:20, 51 = 1:50); 52–54: Y. enterocolitica Yop O:3 (52 = 0.5, 53 = 0.2, 54 = 0.1); 55–59: purified-pig-IgG (55 = 0.3, 56 = 0.2, 57 = 0.1, 58 = 0.05, 59 = 0.01); 60–64: native-pig-IgM (60 = 0.3, 61 = 0.2, 62 = 0.1, 63 = 0.05, 64 = 0.01); 65–67: recombinant protein A/G-HRP (65 = 0.2, 66 = 0.1, 67 = 0.05); 68: buffer; 69: biotinylated oligonucleotide.

Microarray test protocol

The test protocol for microarray analysis is presented in Table 2. The test principle can be explained as follows: If specific antibodies were present in the pig serum sample, they bound to the corresponding antigen spot during the 60 minutes of sample incubation time. Unbound material was removed by washing. In a second incubation step, the attached antibodies were marked with an anti-pig IgG-HRP conjugate (Sigma-Aldrich Chemie GmbH, Taufkirchen, Germany). Unbound conjugate was removed by washing. By adding the HRP substrate solution D1 (Abbott/Alere Technologies GmbH), a colorimetric reaction was initiated at every spot where the conjugate had bound. The substrate solution was removed after ten minutes. Subsequently, an image of every microarray was taken by the ArrayMate reading device (Abbott/Alere Technologies GmbH). The test protocol was provided by Abbott/Alere Technologies GmbH and adjustments (e.g. the serum dilution, incubation time, shaking) were made according to preliminary tests with microarrays from previous test productions. In order to prevent false positive colorimetric reactions due to the deployed blocking solution, sample diluent buffer, conjugate or substrate from occurring, the final test protocol was tested with three microarrays only using the sample diluent buffer ‘pigtype blue’ (Indical) and no pig serum as sample material.

Table 2. Test protocol for microarray analysis.

Step Reagent Dilution Volume [μl] Temperature [°C] Shaking Time
1. Washing protein binding buffer P1 1 - 500 37 400 rpm 5 min
2. Blocking blocking solution 2 - 100 37 300 rpm 30 min
3. Sample serum + sample diluent buffer ‘pigtype blue’ 2 1:50 100 37 - 60 min
4. Washing Protein binding buffer P1 1 - 350 RT 3 - 3 times 4
5. Conjugate anti-pig IgG-HRP (Sigma) + conjugate stabilizer 2 1:10000 100 37 300 rpm 30 min
6. Washing protein binding buffer P1 1 - 350 RT 3 - 3 times 4
7. Substrate HRP substrate solution D1 1 - 100 RT 3 - 10 min

1 Manufacturer: Abbott/Alere Technologies GmbH.

2 Manufacturer: Indical Bioscience GmbH.

3 RT = Room temperature (18–22°C).

4 350 μL protein binding buffer P1 was pipetted in the tube and directly aspirated. This process was repeated three times.

Microarray image analysis

The IconoClust software (Abbott/Alere Technologies GmbH) on the ArrayMate reading device performed the automated image analysis and output a corresponding text file with measured signal intensity for every spot. The text file of the analyzed microarray was converted into a comma separated values file by using the software Result Collector Raw 2.0 (Abbott/Alere Technologies GmbH). The signal intensities of the spot replicates were summarized to one value by forming the median in Microsoft Excel 2010 (Redmond, Washington, USA). Signal intensities can range between 0 (no signal, white spot) and 1 (maximum signal, black spot). According to a study concerning a previously developed microarray by Abbott/Alere Technologies GmbH, signal intensities between 0.1 and 0.7 are within the dynamic range of the test [31]. Signal intensities below 0.1 cannot be assumed to show a correct antigen-antibody binding and signal intensities above 0.7 indicate a color saturation of the spot. If disruptive factors such as protein residues, scratches, dust or lint are visible on the image, the IconoClust software may read the spot as being invalid. An example of a processed microarray chip after image analysis is shown in Fig 2.

Fig 2. Example of a processed microarray chip.

Fig 2

The iconoclast software of the ArrayMate reading device localizes the different antigen spots. The spot area is marked with a red circle. The signal intensity of every spot is calculated from 30% of the darkest pixels within the red circle. Red crosses represent invalid measurements. The original size of the chip is 4.36 mm x 4.36 mm.

Selection of reference samples for microarray analysis

In total, 119 of the obtained pig serum samples were analyzed with the newly developed microarray. To optimally cover the measuring range of each individual ELISA test, a panel of serum samples for microarray analysis was assembled as follows: Firstly, the minimum, the maximum and three values close to the ELISA cut-off were chosen from the individual ELISA test results. In addition, the range of results from the 5% percentile to the 95% percentile of every ELISA test was divided into eight equal intervals. The serum samples that were most closely measured to the interval borders were selected. This method was chosen to test and develop the microarray with field sera, based on the occurrence of antibodies in the target population.

Results of the selected reference samples for microarray analysis are shown in Table 3. The full results of the 184 pig serum samples as well as the optical density values for positive and negative controls of the ELISA tests are presented in S1 Table. For the pathogens, Trichinella spp. and T. gondii sampling at the abattoirs did not yield sufficient positive samples. Therefore, nine additional positive Trichinella spp. serum samples from pig infection trials were offered by the German National Reference Laboratory for Trichinella at the Federal Institute for Risk Assessment (BfR, Berlin, Germany). All nine samples showed a positive test result with the in-house ELISA test of the BfR. For T. gondii, five positive samples were collected at the abattoirs and 20 additional positive serum samples were offered by the MVZ Diamedis laboratory (MVZ Diamedis GmbH, Bielefeld, Germany). These 20 samples were field samples from a German abattoir and were tested positive with the PrioCHECK Toxoplasma Ab porcine ELISA (Prionics AG, Zurich, Switzerland). Due to the small volume of the additional Trichinella spp. and T. gondii samples, no further ELISA tests for the other pathogens could be performed with these samples. Therefore, the results of these 29 microarrays (nine positive samples for Trichinella spp. plus 20 positive samples for T. gondii) exclusively contributed to the analysis of the Trichinella spp. and T. gondii antigen, respectively.

Table 3. Results of the receiver operating characteristic (ROC) curve analysis for 12 different antigens.

Antigen ELISA Microarray
ELISA positive samples ELISA negative samples Antigen concentration
(μg/μl)
AUC
(95% CI)
Cut-off Sensitivity Specificity
T. gondii 25 85 0.5 0.907
(0.819–0.995)
0.112 1 0.84 0.953
Trichinella spp. 9 90 1:50 0.538
(0.323–0.753)
0.008 1 0.444 0.756
Y. enterocolitica mix 39 51 0.3 0.861
(0.784–0.939)
0.032 1 0.872 0.765
Y. enterocolitica
Yop O:3
39 51 0.2 0.967
(0.934–1)
0.195 1 0.923 0.941
Hepatitis E virus 44 46 0.25 0.608
(0.491–0.725)
0.081 1 0.909 0.326
M. avium 14 76 0.1 0.797
(0.685–0.909)
0.024 1 0.857 0.671
M. hyopneumoniae 60 30 1:20 0.942
(0.887–0.996)
0.197 1 0.983 0.8
A. pleuropneumoniae 56 34 1:10 0.766
(0.66–0.873)
0.025 1 0.804 0.706
Influenza A virus 36 54 0.2 0.625
(0.506–0.743)
0.012 1 0.694 0.556
Salmonella spp. ELISA mix 38 52 0.75 0.645
(0.529–0.76)
0.333 1 0.289 0.942
Salmonella spp.
in-house mix
38 52 0.75 0.568
(0.445–0.692)
0.541 1 0.237 0.962
PRRSV
in-house mix
64 26 0.75 0.87
(0.798–0.943)
0.19 2 0.781 0.846

The data of the ROC analysis is shown for the antigen concentration which exceeded the highest area under the curve (AUC).

1 The cut-off value was set to the maximum Youden Index.

2 The cut-off value was set to a value where sensitivity equals specificity.

Statistical analysis

Statistical analysis was performed with R version 3.3.1 [32] and Microsoft Excel 2010. Receiver operating characteristic (ROC) curve analysis using the ELISA test results as reference was set up with the pROC package in R [33]. To determine the accuracy of the microarray, the expressed area under the curve (AUC) for every antigen concentration, the sensitivity and the specificity were calculated. The method by DeLong [34] was used for calculating AUC confidence intervals.

In general, the cut-off values were set to the maximum Youden Index [35]. As this method resulted in an unfavorable ratio of sensitivity and specificity regarding the PRRSV in-house mix antigen and the A. pleuropneumoniae 1:5 dilution, the cut-off values for these antigens were set to a value where sensitivity and specificity are almost equally high.

Results

The measured signal intensities on the microarrays and the calculated median values for the different antigen concentrations are presented in S2 and S3 Tables. The results of the ROC analyses are summarized in Table 3. The calculated AUCs, the 95% confidence interval (CI), the cut-off values, the sensitivities and the specificities refer to the antigen concentration with the highest AUC. An AUC from 0.5 to 0.7 is interpreted as less accurate, 0.7 to 0.9 as moderately accurate and 0.9 to 1 as highly accurate [36].

For three antigens (T. gondii, ‘Y. enterocolitica Yop O:3’, M. hyopneumoniae), an AUC above 0.9 was reached, for two antigens (‘Y. enterocolitica mix’, ‘PRRSV in-house mix’), an AUC above 0.8 was reached and for two antigens (M. avium, A. pleuropneumoniae), an AUC above 0.7 was reached. The antigens Trichinella spp., Hepatitis E virus, Influenza A virus, ‘Salmonella spp. ELISA mix’ and ‘Salmonella spp. in-house mix’ reached AUCs between 0.5 and 0.7, but the lower 95% confidence limit did not always exceed 0.5. For the antigens ‘Y. enterocolitica mix’ and M. avium, moderate test accuracies were calculated, but the calculated cut-off values (0.032 and 0.024) were far below a valid signal intensity of 0.1. If the cut-off value was set to 0.1 for these antigens, only low sensitivities and specificities were calculated, regardless of the chosen antigen concentration. For the A. pleuropneumoniae antigen, the calculated cut-off value (0.025) also did not exceed 0.1, but regarding the antigen dilution of 1:5, a moderate test accuracy of 0.745 (CI: 0.643–0.846) was reached as well. In the case of the A. pleuropneumoniae 1:5 dilution, the sensitivity was 0.59 and the specificity was 0.588 when the cut-off was set to 0.172.

The plots of the ROC curves including the AUC for every spotted antigen concentration are shown in Fig 3 for the zoonotic agents and in Fig 4 for the respiratory diseases. The ROC plots are presented as smooth curves, but the AUCs were calculated from the non-smooth curves. The different colors of the curves refer to the different antigen concentrations spotted on the microarray. The closer the curve passes through the upper left corner, the more efficient is the test. A test with no discriminative ability would result in a curve that falls on the diagonal line (AUC = 0.5) [37].

Fig 3. ROC plots of antigens for zoonotic agents spotted on the microarray.

Fig 3

ELISA tests are used as reference tests. The number of positive and negative samples used to calculate the ROC analyses for the different antigen concentrations are shown in Table 3.

Fig 4. ROC plots of antigens for respiratory diseases spotted on the microarray.

Fig 4

ELISA tests are used as reference tests. The number of positive and negative samples used to calculate the ROC analyses for the different antigen concentrations are shown in Table 3.

For the purified-pig-IgG control, five different antigen concentrations were tested. Clearly positive signal intensities between 0.567 and 0.821 were measured with the concentrations 0.05, 0.1, 0.2, and 0.3 μg/μL on all tested microarrays. This meant that all these four purified-pig-IgG concentrations would be suitable to control a correct binding to the deployed secondary antibody anti-pig IgG-HRP.

On the three microarrays that were tested with the sample diluent buffer ‘pigtype blue’ (Indical) as sample material, only very low signal intensities between 0 and 0.074 were measured on the antigen concentrations presented in Table 1. This confirms that the background coloration on the tested antigen concentrations was negligible.

Among the replicates that were spotted for the different antigen concentrations presented in Table 1, the standard deviation ranged from 0 to 0.25 on the 119 microarrays. The average standard deviation for the different antigen concentrations was 0.013. By forming the median, the impact of outliers among the replicates was diminished.

A total of 17017 spots were measured for the antigen concentrations presented in Table 1 on the 119 microarrays. Regarding these antigen spots, 2.99% were evaluated as invalid by the IconoClust software. However, 80.51% of the 2.99% invalid measurements did not affect the antigen concentrations which achieved the highest AUC. They were most frequently related to the ‘PRRSV in-house mix’ antigen in the concentrations 0.2 (18.11%) and 0.5 (13.58%) and the M. hyopneumoniae antigen in the dilution 1:50 (15.75%).

Discussion

The major challenge in developing a microarray as serological screening test is to produce a microarray with antigens that do not lose their ability to bind specific antibodies either through the manufacturing process of the microarray or through the fact that the same test protocol (e.g. the same conjugate, incubation time, serum dilution) is applied on every antigen. With the newly developed microarray, the suitability of antigens from ELISA manufacturers and their level of agreement to conventional ELISA tests were investigated. ELISA tests of the same ELISA manufacturers are often performed with uniform test reagents (e.g. conjugate stabilizer, sample diluent buffer), which is also required for the simultaneous measurements on a microarray.

Using the ELISA tests as reference tests in our study offered the advantage of being able to compare the microarray to a uniform method, which is equal in quality. However, the sensitivities and specificities of these ELISA tests cannot be assumed to be 100%, which leads to obvious bias in the accuracy estimates for the microarray. In cases where the new diagnostic test is more sensitive than the reference test, this appears as diminished diagnostic specificity. Is the new test more specific than the reference test, this appears as diminished diagnostic sensitivity [38]. This means that false positive or false negative results on the microarray may in fact be correct because of a misclassification by the ELISA test. The choice of the ELISA test as gold standard represents a limitation of this study but is justified by the interest in comparing the accuracy of the microarray antigens with the widely used ELISA format. Standard reference sera containing antibodies of known concentration for all ten pathogens were not available. According to the recommendations for the validation of diagnostic tests published by the World Organisation for Animal Health (OIE), the reference panel for validation should represent known infected and uninfected animals from the target population over the intended operating range of the assay [39]. To comply with this, it was only possible to build our own reference panel with the help of the ELISA tests.

Regarding the zoonotic agents, two antigens (T. gondii, ‘Y. enterocolitica Yop O:3’) showed high test accuracies with valid cut-off values above 0.1. For T. gondii, the ROC curve ascended quickly, but leveled off as it approached a sensitivity of 0.84 (see Fig 3). Due to the asymmetrical ROC curve, achieving a higher sensitivity is not possible by lowering the cut-off value. Nevertheless, in comparison to three commercial T. gondii ELISA tests that were validated by Steinparzer et al. [40] (sensitivities 0.57–0.65), using the microscopic agglutination test as reference method, the calculated sensitivity of the T. gondii antigen on the microarray is still higher. The specificities (0.97–0.99) of the ELISA tests examined by Steinparzer et al. were almost equal to the specificity that was calculated for the microarray antigen (0.95). However, slightly higher sensitivities (0.79–0.96) for three commercial ELISA tests using meat juice as sample material have also been reported [41].

According to Vanantwerpen et al. [42], serological screening of pigs for Y. enterocolitica at herd level would help to reduce the risk of contaminating meat during the slaughter process. In this study, two different antigens for Y. enterocolitica, one native antigen ‘Y. enterocolitica Yop O:3’ and one recombinant antigen ‘Y. enterocolitica mix’, were tested on the microarray. In contrast to what was previously reported by Chen et al. [43], we did not observe lower specificity on the native antigen in comparison to the recombinant antigen. With a native antigen, a binding of non-pathogenic Yersinia antibodies could have possibly resulted in more false positive reactions, but this was not confirmed. Although the antigen was compared to an ELISA test which was produced with a recombinant antigen, the calculated specificity for the ‘Y. enterocolitica Yop O:3’ was high (0.94). A Yersinia antigen from the serotype O:3 was used, since pigs have been shown to be a major reservoir of pathogenic Y. enterocolitica for strains of bioserotype 4/O:3 [44, 45]. When Thibodeau et al. [46] developed a serotype specific ELISA, they recognized preponderance of the serotype O:3 compared to serotype O:5, 27 and O:9.

For M. avium, a high AUC was reached although signal intensities below 0.1 are not considered as valid. This suggests that valid results with high test accuracy might be possible if the antigen was spotted at a higher concentration.

Regarding the production diseases, the M. hyopneumoniae, the APP and the PRRSV antigen showed the highest test accuracies. For the M. hyopneumoniae antigen, the observed sensitivity of 0.98 and specificity of 0.80 almost reached the accuracy that was reported by Liu et al. [47] for a newly developed blocking ELISA, using the IDEXX ELISA as gold standard. The sensitivity of the M. hyopneumoniae antigen on the microarray was even higher than the sensitivity of 0.89 that was stated for the IDEXX ELISA by Meemken et al. [1]. For detecting PRRSV, the EU and the NA genotype antigen had to be spotted as a mixed antigen on the microarray, to be comparable to the reference ELISA test (pigtype PRRSV Ab), which detects both strains as well. When Chu et al. developed an ELISA test for PRRSV, they also achieved highest test accuracy with the antigen that combined both strains [48]. For A. pleuropneumoniae, a mixed antigen containing the serotypes 1 to 12 was used. The serotypes could also be spotted individually in order to analyze the antigen binding of the different serotypes separately. A similar approach was adopted in a previous study by Berger et al. [49], where five serotypes had been tested with a bead-based multiplexed immunoassay.

For Salmonella spp., Trichinella spp., Hepatitis E virus and Influenza A virus, different antigens need to be tested or the antigen binding to the microarray surface needs to be improved to achieve better functionality for the antigens. The epoxide groups on a 3D-linker couple most biomolecules. If the 3D structures of the antigens are influenced by this, is not predictable and cannot be excluded. A clear relationship between the nature of the antigen and the functionality on the microarray chip could not be shown. Concluding from our observations it may be relevant for developers of similar multi-array test systems to consider a series of antigen formulations in the feasibility phase since it cannot be taken for granted that standard formulations developed for ELISA systems perform equally well on microarray chips.

During the manufacturing process, it was necessary to overcome the difficulty that some antigen spots began to diverge and migrate with surrounding spots directly after the spotting process due to the enlargement of their spot diameter. This could be minimized by buffering the antigen in a buffering solution that is free of detergents. Increasing spot diameters due to adding a detergent during the development of an antigen microarray has also been described by Staudt et al. [50]. Nevertheless, the antigen spots of the highest antigen concentrations of PRRSV, M. hyopneumoniae and A. pleuropneumoniae also enlarged their spot diameter during the manufacturing process without adding detergents to the buffering solution. This might be due to the high antigen concentration or the protein itself. As a precaution, the aforementioned antigen spots were placed at a larger distance from each other (Fig 1). The read-out process with the ArrayMate reading device was not affected by the larger spot diameter as the IconoClust software only considers the darkest 30% of the pixels of a spot to calculate the signal value, regardless of the spot size.

With regard to invalid measurements, the calculated rate of 3.79% invalid measurements on the microarray was already satisfactory. Microarray data have been described to contain usually more than 5% missing values [51] or to vary between 0.8% and 10% [52]. The percentage of invalid measurements would even be lower if antigen concentrations that were found to be redundant could be excluded from the microarray layout. The precision of the microarray can also be considered good since a very small average standard deviation was observed among the replicates. It would be appropriate to maintain the spotting of replicates in order to minimize the risk of an antigen spot failing due to an invalid measurement.

For interpreting the microarray data, it must be kept in mind that acutely infected animals which only produce immunoglobulin M (IgM) antibodies would not show a positive test result with this microarray, if the test protocol shown in Table 2 is used. As a conjugate which binds to immunoglobulin G (IgG) is applied, only these antibodies are measured. IgG antibody production usually starts three weeks after the infection [53]. All ELISA tests used in this study use a conjugate that only detects IgG, therefore the same type of antibodies were measured with both assays. For the purpose of this assay IgG antibodies are more relevant, but it would also be possible to run the microarray with a conjugate that binds to IgM after the IgG has been depleted or removed.

In order to improve herd health management and food safety by collecting serological data, Meemken at al. described that a constant monitoring of pigs is necessary [1]. The sample size should be at least 60 samples (blood serum or meat juice) per herd to detect diseases with an intra-herd prevalence of 5% [54]. To examine such a large number of pigs with the microarray continuously, the microarray would have to be transferred to other platforms such as bead-based array platforms or the ArrayStrip platform (Abbott/Alere Technologies GmbH) to achieve higher sample throughput. Moreover, by automating individual steps of the test protocol, such as the washing steps, a more efficient analysis could be performed. In many European countries, the sampling of large sample sizes at herd level is already implemented at abattoirs because of a national Salmonella monitoring program. In Germany, blood serum or meat juice can be sampled for the national Salmonella monitoring program, whereby the meat juice sampling is far more established. It would be very convenient and cost-effective if these samples could also be used for microarray analysis.

Conclusion

In summary, the approach of using a microarray as multi-diagnostic tool to examine pig serum was proved successful. By applying the newly developed microarray, antibodies against bacterial, viral and parasitic pathogens in pigs could be detected simultaneously. A high level of agreement with conventional ELISA tests was achieved for two zoonotic agents (T. gondii, Y. enterocolitica) and three production diseases (A. pleuropneumoniae, PRRSV, M. hyopneumoniae). In comparison to the analysis time required to conduct five respective ELISA tests, the microarray offers considerable time saving.

Supporting information

S1 Table. Optical density values of the ELISA tests.

Results represent the measured optical density values of the ELISA tests of 184 pig serum samples as well as the optical density values of the positive and negative controls from every ELISA plate. Samples that were selected for microarray analysis are highlighted with a gray background.

(XLSX)

S2 Table. Measured spot intensities on 122 microarrays.

Results represent the measured signal intensities on the antigen spots from the antigens presented in Table 1 and the signal intensities measured on the purified-pig-IgG spots. One hundred and nineteen microarrays were performed with pig serum and three microarrays were performed with sample diluent buffer as sample material.

(XLSX)

S3 Table. Median values of the measured spot intensities on 122 microarrays.

Results represent the calculated median values from the microarray.

(XLSX)

Acknowledgments

The authors wish to thank Kristine Klewer-Fromentin and Dr. Thomas Schumacher for providing antigens, Hendrik Arkenberg, Martijn Bouwknegt, Lena Bramlage, Kerstin Bremer, Mechthild Busemann, Frank Holte, Dr. Caroline Lüken, Dr. Gerald Otto and Linda Vornhusen for their support with the reference samples and Beate Cuenca Serrano and Dr. Anne Mayer-Scholl for providing additional sample material.

Data Availability

All relevant data are within the manuscript and its supporting files.

Funding Statement

This work has received funding from the European Innovation Partnership for Agricultural Productivity and Sustainability (EIP-AGRI, https://ec.europa.eu/eip/agriculture/) to DM. The funder provided support in the form of salaries for authors KL and SM. This publication was also supported by Deutsche Forschungsgemeinschaft and University of Veterinary Medicine Hannover, Foundation within the funding programme Open Access Publishing. Both funders did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. Abbott/Alere Technologies GmbH and Indical Bioscience GmbH provided support in the form of salaries for authors RH and CE, but did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. The specific roles of these authors are articulated in the ‘author contributions’ section.

References

  • 1.Meemken D, Tangemann AH, Meermeier D, Gundlach S, Mischok D, Greiner M, et al. Establishment of serological herd profiles for zoonoses and production diseases in pigs by “meat juice multi-serology”. Preventive Veterinary Medicine. 2014;113(4):589–98. 10.1016/j.prevetmed.2013.12.006 [DOI] [PubMed] [Google Scholar]
  • 2.Felin E, Jukola E, Raulo S, Fredriksson-Ahomaa M. Meat Juice Serology and Improved Food Chain Information as Control Tools for Pork-Related Public Health Hazards. Zoonoses and public health. 2015;62(6):456–64. 10.1111/zph.12174 . [DOI] [PubMed] [Google Scholar]
  • 3.EFSA. Scientific Opinion on the public health hazards to be covered by inspection of meat (swine). EFSA Journal. 2011;9(10):2351 10.2903/j.efsa.2011.2351 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Agdestein A, Olsen I, Jorgensen A, Djonne B, Johansen TB. Novel insights into transmission routes of Mycobacterium avium in pigs and possible implications for human health. Veterinary research. 2014;45:46 Epub 2014/04/20. 10.1186/1297-9716-45-46 ; PubMed Central PMCID: PMCPmc4021465. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Salines M, Andraud M, Rose N. From the epidemiology of hepatitis E virus (HEV) within the swine reservoir to public health risk mitigation strategies: a comprehensive review. Veterinary research. 2017;48:31 10.1186/s13567-017-0436-3 PMC5445439. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Alban L, Steenberg B, Stephensen FT, Olsen AM, Petersen JV. Overview on current practices of meat inspection in the EU. EFSA Supporting Publications. 2011;8(10). 10.2903/sp.efsa.2011.EN-190 [DOI] [Google Scholar]
  • 7.Berthe F, Vannier P, Have P, Serratosa J, Bastino E, Maurice Broom D, et al. The role of EFSA in assessing and promoting animal health and welfare. EFSA Journal. 2012;10(10):s1002 10.2903/j.efsa.2012.s1002 [DOI] [Google Scholar]
  • 8.Maes D, Deluyker H, Verdonck M, Castryck F, Miry C, Vrijens B, et al. Herd factors associated with the seroprevalences of four major respiratory pathogens in slaughter pigs from farrow-to-finish pig herds. Veterinary research. 2000;31(3):313–27. Epub 2000/06/23. 10.1051/vetres:2000122 . [DOI] [PubMed] [Google Scholar]
  • 9.Opriessnig T, Giménez-Lirola LG, Halbur PG. Polymicrobial respiratory disease in pigs. Animal Health Research Reviews. 2011;12(2):133–48. Epub 12/09. 10.1017/S1466252311000120 [DOI] [PubMed] [Google Scholar]
  • 10.Shi M, Lam TT-Y, Hon C-C, Hui RK-H, Faaberg KS, Wennblom T, et al. Molecular epidemiology of PRRSV: A phylogenetic perspective. Virus Research. 2010;154(1):7–17. 10.1016/j.virusres.2010.08.014. [DOI] [PubMed] [Google Scholar]
  • 11.Fraile L, Alegre A, López-Jiménez R, Nofrarías M, Segalés J. Risk factors associated with pleuritis and cranio-ventral pulmonary consolidation in slaughter-aged pigs. The Veterinary Journal. 2010;184(3):326–33. 10.1016/j.tvjl.2009.03.029 [DOI] [PubMed] [Google Scholar]
  • 12.Merialdi G, Dottori M, Bonilauri P, Luppi A, Gozio S, Pozzi P, et al. Survey of pleuritis and pulmonary lesions in pigs at abattoir with a focus on the extent of the condition and herd risk factors. The Veterinary Journal. 2012;193(1):234–9. 10.1016/j.tvjl.2011.11.009 [DOI] [PubMed] [Google Scholar]
  • 13.Elnifro EM, Ashshi AM, Cooper RJ, Klapper PE. Multiplex PCR: Optimization and Application in Diagnostic Virology. Clinical Microbiology Reviews. 2000;13(4):559–70. PMC88949. 10.1128/cmr.13.4.559-570.2000 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Dunbar SA. Applications of Luminex xMAP technology for rapid, high-throughput multiplexed nucleic acid detection. Clinica Chimica Acta. 2006;363(1):71–82. 10.1016/j.cccn.2005.06.023 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Ekins RP. Multi-analyte immunoassay. Journal of pharmaceutical and biomedical analysis. 1989;7(2):155–68. Epub 1989/01/01. . [DOI] [PubMed] [Google Scholar]
  • 16.Ehricht R, Adelhelm K, Monecke S, Huelseweh B. Application of protein arraytubes to bacteria, toxin, and biological warfare agent detection. Methods in molecular biology (Clifton, NJ). 2009;509:85–105. Epub 2009/02/13. 10.1007/978-1-59745-372-1_6 . [DOI] [PubMed] [Google Scholar]
  • 17.Giammarioli M, Pellegrini C, Casciari C, De Mia GM. Development of a novel hot-start multiplex PCR for simultaneous detection of classical swine fever virus, African swine fever virus, porcine circovirus type 2, porcine reproductive and respiratory syndrome virus and porcine parvovirus. Veterinary research communications. 2008;32(3):255–62. Epub 2007/11/03. 10.1007/s11259-007-9026-6 . [DOI] [PubMed] [Google Scholar]
  • 18.Haines FJ, Hofmann MA, King DP, Drew TW, Crooke HR. Development and validation of a multiplex, real-time RT PCR assay for the simultaneous detection of classical and African swine fever viruses. PLoS One. 2013;8(7):e71019 Epub 2013/08/08. 10.1371/journal.pone.0071019 ; PubMed Central PMCID: PMCPmc3724773. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Chang CY, Deng MC, Wang FI, Tsai HJ, Yang CH, Chang C, et al. The application of a duplex reverse transcription real-time PCR for the surveillance of porcine reproductive and respiratory syndrome virus and porcine circovirus type 2. J Virol Methods. 2014;201:13–9. Epub 2014/02/25. 10.1016/j.jviromet.2014.01.016 . [DOI] [PubMed] [Google Scholar]
  • 20.Wu H, Rao P, Jiang Y, Opriessnig T, Yang Z. A sensitive multiplex real-time PCR panel for rapid diagnosis of viruses associated with porcine respiratory and reproductive disorders. Mol Cell Probes. 2014;28(5–6):264–70. Epub 2014/07/22. 10.1016/j.mcp.2014.07.001 . [DOI] [PubMed] [Google Scholar]
  • 21.Bokken GCAM Bergwerff AA, Fv Knapen. A novel bead-based assay to detect specific antibody responses against Toxoplasma gondii and Trichinella spiralis simultaneously in sera of experimentally infected swine. BMC Veterinary Research. 2012;8:36–. 10.1186/1746-6148-8-36 PMC3348074. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.van der Wal FJ, Achterberg RP, Kant A, Maassen CB. A bead-based suspension array for the serological detection of Trichinella in pigs. Veterinary journal. 2013;196(3):439–44. 10.1016/j.tvjl.2012.10.029 . [DOI] [PubMed] [Google Scholar]
  • 23.Wang X, Dang E, Gao J, Guo S, Li Z. Development of a gold nanoparticle-based oligonucleotide microarray for simultaneous detection of seven swine viruses. Journal of Virological Methods. 2013;191(1):9–15. 10.1016/j.jviromet.2013.03.023 [DOI] [PubMed] [Google Scholar]
  • 24.Wutz K, Meyer VK, Wacheck S, Krol P, Gareis M, Nolting C, et al. New route for fast detection of antibodies against zoonotic pathogens in sera of slaughtered pigs by means of flow-through chemiluminescence immunochips. Analytical chemistry. 2013;85(10):5279–85. 10.1021/ac400781t . [DOI] [PubMed] [Google Scholar]
  • 25.Lung O, Ohene-Adjei S, Buchanan C, Joseph T, King R, Erickson A, et al. Multiplex PCR and Microarray for Detection of Swine Respiratory Pathogens. Transboundary and emerging diseases. 2017;64(3):834–48. 10.1111/tbed.12449 . [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Kohler C, Dunachie SJ, Muller E, Kohler A, Jenjaroen K, Teparrukkul P, et al. Rapid and Sensitive Multiplex Detection of Burkholderia pseudomallei-Specific Antibodies in Melioidosis Patients Based on a Protein Microarray Approach. PLoS neglected tropical diseases. 2016;10(7):e0004847 Epub 2016/07/20. 10.1371/journal.pntd.0004847 ; PubMed Central PMCID: PMCPmc4948818. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Selle M, Hertlein T, Oesterreich B, Klemm T, Kloppot P, Muller E, et al. Global antibody response to Staphylococcus aureus live-cell vaccination. Sci Rep. 2016;6:24754 Epub 2016/04/23. 10.1038/srep24754 ; PubMed Central PMCID: PMCPmc4840433. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Monecke S, Muller E, Buchler J, Stieber B, Ehricht R. Staphylococcus aureus in vitro secretion of alpha toxin (hla) correlates with the affiliation to clonal complexes. PLoS One. 2014;9(6):e100427 Epub 2014/06/19. 10.1371/journal.pone.0100427 ; PubMed Central PMCID: PMCPmc4062534. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Huelseweh B, Ehricht R, Marschall HJ. A simple and rapid protein array based method for the simultaneous detection of biowarfare agents. Proteomics. 2006;6(10):2972–81. Epub 2006/04/20. 10.1002/pmic.200500721 . [DOI] [PubMed] [Google Scholar]
  • 30.Hahne S. Entwicklung und Validierung eines Protein-Microarrays zur simultanen serologischen Untersuchung von Fleischsaftproben auf Erreger von Zoonosen und Produktionskrankheiten beim Schwein. Elektronische Ressource. Hannover: Tierärztliche Hochschule Hannover; 2014. 153 p.
  • 31.Stieber B, Monecke S, Müller E, Baier V, W. Coombs G, Ehricht R. Development and usage of protein microarrays for the quantitative measurement of Panton-Valentine leukocidin. Molecular and Cellular Probes. 2014;28(4):123–32. 10.1016/j.mcp.2013.11.003 [DOI] [PubMed] [Google Scholar]
  • 32.Team RC. R: A language and environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria. 2016.
  • 33.Robin X, Turck N, Hainard A, Tiberti N, Lisacek F, Sanchez JC, et al. pROC: an open-source package for R and S plus to analyze and compare ROC curves. BMC Bioinformatics. 2011;12:8 10.1186/1471-2105-12-77 WOS:000288983700001. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.DeLong ER, DeLong DM, Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics. 1988;44(3):837–45. Epub 1988/09/01. . [PubMed] [Google Scholar]
  • 35.Youden WJ. Index for rating diagnostic tests. Cancer. 1950;3(1):32–5. Epub 1950/01/01. . [DOI] [PubMed] [Google Scholar]
  • 36.Gardner IA, Greiner M. Receiver-operating characteristic curves and likelihood ratios: improvements over traditional methods for the evaluation and application of veterinary clinical pathology tests. Veterinary Clinical Pathology. 2006;35(1):8–17. [DOI] [PubMed] [Google Scholar]
  • 37.Swets JA. Measuring the accuracy of diagnostic systems. Science (New York, NY). 1988;240(4857):1285–93. Epub 1988/06/03. . [DOI] [PubMed] [Google Scholar]
  • 38.Staquet M, Rozencweig M, Lee YJ, Muggia FM. Methodology for the assessment of new dichotomous diagnostic tests. Journal of Chronic Diseases. 1981;34(12):599–610. 10.1016/0021-9681(81)90059-X [DOI] [PubMed] [Google Scholar]
  • 39.OIE. Develoment and optimisation of antibody detection assays. Manual of Diagnostic Tests and Vaccines for Terrestrial Animals. 2014;Chapter 3.6.1.
  • 40.Steinparzer R, Reisp K, Grunberger B, Kofer J, Schmoll F, Sattler T. Comparison of different commercial serological tests for the detection of Toxoplasma gondii antibodies in serum of naturally exposed pigs. Zoonoses and public health. 2015;62(2):119–24. Epub 2014/04/16. 10.1111/zph.12122 . [DOI] [PubMed] [Google Scholar]
  • 41.Felin E, Näreaho A, Fredriksson-Ahomaa M. Comparison of commercial ELISA tests for the detection of Toxoplasma antibodies in the meat juice of naturally infected pigs. Veterinary Parasitology. 2017;238:30–4. 10.1016/j.vetpar.2017.03.012 [DOI] [PubMed] [Google Scholar]
  • 42.Vanantwerpen G, Berkvens D, De Zutter L, Houf K. Association between microbiological and serological prevalence of human pathogenic Yersinia spp. in pigs and pig batches. Veterinary Microbiology. 2015;178(1):114–8. 10.1016/j.vetmic.2015.05.004 [DOI] [PubMed] [Google Scholar]
  • 43.Chen X, Chen X, Lu X, Feng X, Wen H. The production and comparative evaluation of native and recombinant antigens for the fast serodiagnosis of cystic echinococcosis with dot immunogold filtration assay. Parasite immunology. 2015;37(1):10–5. Epub 2014/10/15. 10.1111/pim.12151 . [DOI] [PubMed] [Google Scholar]
  • 44.Fredriksson-Ahomaa M, Hallanvuo S, Korte T, Siitonen A, Korkeala H. Correspondence of genotypes of sporadic Yersinia enterocolitica bioserotype 4/O:3 strains from human and porcine sources. Epidemiology and Infection. 2001;127(1):37–47. PMC2869727. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 45.Fredriksson-Ahomaa M, Stolle A, Siitonen A, Korkeala H. Sporadic human Yersinia enterocolitica infections caused by bioserotype 4/O: 3 originate mainly from pigs. Journal of medical microbiology. 2006;55(Pt 6):747–9. 10.1099/jmm.0.46523-0 . [DOI] [PubMed] [Google Scholar]
  • 46.Thibodeau V, Frost EH, Quessy S. Development of an ELISA procedure to detect swine carriers of pathogenic Yersinia enterocolitica. Veterinary Microbiology. 2001;82(3):249–59. 10.1016/S0378-1135(01)00356-X [DOI] [PubMed] [Google Scholar]
  • 47.Liu M, Du G, Zhang Y, Wu Y, Wang H, Li B, et al. Development of a blocking ELISA for detection of Mycoplasma hyopneumoniae infection based on a monoclonal antibody against protein P65. The Journal of veterinary medical science. 2016;78(8):1319–22. Epub 2016/04/15. 10.1292/jvms.15-0438 PubMed Central PMCID: PMCPmc5053934. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 48.Chu J-Q, Hu X-M, Kim M-C, Park C-S, Jun M-H. Development and validation of a recombinant nucleocapsid protein-based ELISA for detection of the antibody to porcine reproductive and respiratory syndrome virus. The Journal of Microbiology. 2009;47(5):582 10.1007/s12275-009-0033-x [DOI] [PubMed] [Google Scholar]
  • 49.Berger SS, Lauritsen KT, Boas U, Lind P, Andresen LO. Simultaneous detection of antibodies to five Actinobacillus pleuropneumoniae serovars using bead-based multiplex analysis. Journal of veterinary diagnostic investigation: official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc. 2017;29(6):797–804. Epub 2017/07/08. 10.1177/1040638717719481 . [DOI] [PubMed] [Google Scholar]
  • 50.Staudt N, Müller-Sienerth N, Wright GJ. Development of an antigen microarray for high throughput monoclonal antibody selection. Biochemical and biophysical research communications. 2014;445(4):785–90. 10.1016/j.bbrc.2013.12.033 . [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 51.Wang H, Chiu C-C, Wu Y-C, Wu W-S. Shrinkage regression-based methods for microarray missing value imputation. BMC systems biology. 2013;7 Suppl 6(Suppl 6):S11–S. 10.1186/1752-0509-7-S6-S11 . [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 52.de Brevern AG, Hazout S, Malpertuy A. Influence of microarrays experiments missing values on the stability of gene groups by hierarchical clustering. BMC Bioinformatics. 2004;5:114–. 10.1186/1471-2105-5-114 . [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 53.Tizard IR. Veterinary Immunology: An Introduction. University of Michigan: Saunders; 2004. [Google Scholar]
  • 54.Cannon RM, Roe RT, Australian Bureau of Animal H, Department of Primary I. Livestock disease surveys: a field manual for veterinarians Canberra, Australia: Australian Government Pub. Service; 1982. [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

S1 Table. Optical density values of the ELISA tests.

Results represent the measured optical density values of the ELISA tests of 184 pig serum samples as well as the optical density values of the positive and negative controls from every ELISA plate. Samples that were selected for microarray analysis are highlighted with a gray background.

(XLSX)

S2 Table. Measured spot intensities on 122 microarrays.

Results represent the measured signal intensities on the antigen spots from the antigens presented in Table 1 and the signal intensities measured on the purified-pig-IgG spots. One hundred and nineteen microarrays were performed with pig serum and three microarrays were performed with sample diluent buffer as sample material.

(XLSX)

S3 Table. Median values of the measured spot intensities on 122 microarrays.

Results represent the calculated median values from the microarray.

(XLSX)

Data Availability Statement

All relevant data are within the manuscript and its supporting files.


Articles from PLoS ONE are provided here courtesy of PLOS

RESOURCES