Skip to main content
Journal of Research of the National Bureau of Standards. Section A, Physics and Chemistry logoLink to Journal of Research of the National Bureau of Standards. Section A, Physics and Chemistry
. 1964 Nov-Dec;68A(6):593–599. doi: 10.6028/jres.068A.057

Absolute Isotopic Abundance Ratio and the Atomic Weight of Bromine

Edward J Catanzaro, Thomas J Murphy, Ernest L Garner, William R Shields
PMCID: PMC6592381  PMID: 31834743

Abstract

An absolute value is obtained for the isotopic abundance ratio of bromine using thermal emission mass spectrometers calibrated for bias by the use of samples of known isotopic composition prepared from nearly pure separated bromine isotopes. The resulting absolute Br79/Br81 ratio is 1.02784 ±0.00190 which yields an atomic weight (C12=12) of 79.90363 ±0.00092. The indicated uncertainties are overall limits of error based on 95 percent confidence limits for the mean and allowances for the effects of known sources of possible systematic error plus a component to cover possible natural variations in isotopic composition although no provable variations were noted among the Br79/Br81ratios of 29 commercial and natural samples. Mass spectroinetric determinations of the atomic weights of bromine and silver give a combining weight ratio of AgBr/Ag= 1.740752.

1. Introduction

The atomic weights of silver, chlorine, and bromine form the classical basis for establishing atomic weights of many of the elements. Recent mass spectroinetric determinations of the atomic weights of silver [1]1 and chlorine [2] have yielded values of 107.8682 ±0.00102 and 35.45273+0.0009220.00097, respectively. The present work extends the study to bromine.

A number of mass spectrometric determinations of bromine isotopic abundances have been reported in the literature. Blewett [3], Williams and Yuster [4], White and Cameron [5], and Cameron and Lippert [6] used electron bombardment ion sources and obtained values of Br79/Br81= 1.026 ±0.026, 1.021 ±0.004, 1.0210 ±0.0020, and 1.0217 ±0.0002, respectively. However, none of these studies included a direct measurement of instrumental bias and, therefore, the resulting ratios were not absolute. White and Cameron [5] recognized that discrepancies between observers and instruments were probably due to mass discrimination occurring in the ion lenses of the sources, but were unable to measure or correct for this discrimination. Cameron and Lippert [6] took care to avoid fractionation during the chemical preparation of their samples, but only asserted that their method of measurement, sublimation of sodium bromide, was free of any instrumental discrimination. They did not attempt to verify this assertion in any manner.

In the present study, both mass spectrometers were calibrated for bias by the use of samples of known isotopic composition, prepared from nearly pure separated bromine isotopes. The measured biases were then used to obtain the absolute Br79/Br81 ratio of a reference sample of commercial sodium bromide. In addition, the Br79/Br81 ratios of a number of samples of commercial purified bromine and bromide from brines and minerals were also measured.

2. Experimental Procedure

2.1. Mass Spectrometry

All isotopic measurements were made using two nearly identical solid-source single-focusing mass spectrometers equipped with 68-deg analyser tubes, 60-deg magnet pole pieces and 12-in. radii of curvature. Triple-filament rhenium ribbon (1×30 mils) sources were used and ion currents were measured by means of a vibrating reed electrometer with an expanded-scale recorder. Ratios were measured by varying the magnetic field at constant ion-accelerating voltage.

The bromide was deposited on the sample filaments in the form of ammoniacal solutions of silver bromide. Preliminary experiments showed that AgBr was far superior to NaBr with respect to signal stability during the mass spectroinetric analyses. One drop of a AgBr solution containing 3 mg Br/ml (~0.06 mg Br) was deposited on each filament and dried under a heat lamp. To minimize the variability of discrimination, all analyses were made in an identical manner. A strict pattern of filament heating was followed and a set of 10 measurements was made on a growing signal (3–5×10−13 A) between 38 and 52 min after the filaments were turned on. Analyses which did not follow the normal signal-growth pattern were discarded.

2.2. Purification of the Separated Isotopes

Electromagnetically separated isotopes in the form of sodium bromide were obtained from the Isotopes Division, Oak Ridge National Laboratory of the Union Carbide Nuclear Company. The NaBr79 and the NaBr81were designated Series LM, Lot Number 1391(a) and Series LM, Lot Number 1392(a), respectively. The certificate of analysis accompanying each sample indicated a high degree of cationic purity but did not exclude the possible presence of other halides or pseudohalides. Since the bromide ion concentration of solutions was to be determined by silver coulometry and since the halides iodide and chloride, and pseudo-halides, cyanide and thiocyanate, would react with silver to form insoluble compounds [7], the iostopic samples were further purified to insure the removal of these impurities.

Each separated isotope sample (about 5 g) was divided in half and treated as follows: The sodium bromide (about 2.5 g) was dissolved in a small amount of water and transferred to a 300 ml three-neck distilling apparatus like that described by Murphy, Clabaugh, and Gilchrist [8]. The solution volume was increased to 100 ml and 0.2 ml of redistilled nitric acid was added. Twenty milliliters of dilute ammonium hydroxide (1:9) was added to the receiver flask. The solution was then heated to boiling, and refluxed for 2 hr while a stream of halide-free air was drawn through the system. The heat was then increased and about 10 ml of the solution was distilled into the dilute NH4OH solution.

This procedure will oxidize iodide to iodine [9] and remove it from solution while only a small amount of bromide is lost. Tests based on the insolubility of silver iodide in ammoniacal solution have shown that when 0.025 mg of iodide ion was added to a solution containing 2.5 g of NaBr and treated as above, the recovery of iodine was complete, so that in terms of the NaBr the iodine concentration in the solution would be less than 0.001 percent. Tests based on the insolubility of silver cyanide have also shown that if cyanide were present, almost all of it would be removed by the above procedure either as hydrogen cyanide or as cyanogen.

Ten milliliters of water and 20 ml of redistilled nitric acid were added to the sodium bromide solution and the solution was refluxed while a stream of halide free air was drawn through the solution. The bromine liberated was slowly distilled into a solution containing a 20 percent excess of the stoichiometric quantity of sodium carbonate and 5 ml of 30 percent hydrogen peroxide. The distillation was continued until only a slight color of bromine remained in the distilland.

Dilute nitric acid (1:5) has been shown to oxidize bromide to bromine quantitatively [8] without oxidizing chloride to chlorine. Chloride analyses [8] of the distillands after removal of the bromine showed that the chloride concentration was less than 0.001 percent in terms of the NaBr present.

After the distillation of bromine was completed, the distillate was heated on a steam bath until the hydrogen peroxide was decomposed. This oxidation by hydrogen peroxide removed any cyanide [10] or thiocyanate [11] that might have distilled with the bromine. Tests, based on the insolubility of silver cyanide and silver thiocyanate, showed that solutions prepared in this manner contained less than 0.001 percent (CN)or 0.001 percent (SCN) in terms of the NaBr present.

The solution was then transferred to a platinum dish and evaporated to dryness. The dish and contents were covered and heated to 550 °C for 1/2 hr in an electric furnace to convert any bromate present to bromide. Any nitrate present would be converted to nitrite and cause difficulty in the bromine titration. Therefore, the salt mixture, which contained sodium bromide, sodium nitrite, and the excess sodium carbonate, was dissolved in 50 ml of H20 and 1 drop of phenolphthalein indicator solution was added. The solution was neutralized to the phenolphthalein end point with (1:9) acetic acid. An equivalent amount of the dilute acetic acid plus a 1-ml excess was then added to neutralize the bicarbonate produced and make the solution slightly acid. Two milliliters of 30 percent hydrogen peroxide was then added and the solution was heated overnight on a steam bath. Under these conditions nitrite is oxidized to nitrate [12] and the prolonged heating destroys the excess peroxide.

Analyses of sodium bromide solutions prepared in the above manner have shown that the solutions contained less than 0.0005 percent bromate ion, less than 0.0005 percent nitrite ion, and less than 0.0005 percent hydrogen peroxide in terms of the sodium bromide present. The bromate test was based on the reaction of bromate with bromide in acid solution to produce bromine which was detected with o-tolidine. Nitrite was determined with phenylenediamine [13]. The test for hydrogen peroxide was based on its reaction with titanium to form a colored complex [14].

This purification procedure was repeated on the remaining portions of the separated isotope samples for groups II.

Iodide was not detected in either of the starting isotopic samples. Chloride was found in both the NaBr79and the NaBr81to the extent of 0.13 percent and 0.11 percent, respectively. As stated previously, tests have shown that the purification procedure reduced the chloride content of the sodium bromide to less than 0.001 percent. Cyanide and thiocyanate were not determined, but if they had been present originally, the concentration of each would have been reduced to less than 0.001 percent.

2.3. Preparation and Bromide Concentration of Separated Isotope Solutions

The solutions of the purified NaBr79and NaBr81 were filtered and transferred to 100 ml volumetric flasks whose necks had been cut off so that only about 1 cm remained. The solutions were diluted to about 65 ml and thoroughly mixed by swirling the flasks for several minutes. Each flask was then sealed with a rubber serum septum and allowed to stand overnight in the case of a semi-microbalance to insure thermal equilibrium. The flasks and contents were then weighed on the balance to ±0.02 mg. Samples were withdrawn from each flask by inserting a stainless steel needle attached to a glass hypodermic syringe through the rubber septum and withdrawing the desired amount of solution. A second needle which just punctured the septum served as a vent. The syringe and needle were then washed with distilled water and the washings were combined with the bulk of the sample. The weight of the sample withdrawn was determined from the weight of the flask before and after the withdrawal of solution.

Four samples of from 7 to 9 grams each were withdrawn from each solution by this method. The quantity of bromide in each of these samples was from 2 to 3 meq. Each sample was transferred to a 100 ml beaker and the syringe and needle were washed with distilled water, the washings being caught in the beaker with the bulk of the aliquot. The volume was adjusted to about 15 ml by evaporation on a steam bath.

The bromide ion concentration of each solution was determined by constant-current coulometry using electrically generated silver ions. The end point of the silver titration was determined amperometrically. The details of the method are described by Marinenko and Taylor [15].

This procedure was first applied to solutions prepared from sodium bromide low in iodide and chloride. This sodium bromide was prepared in our laboratory since all of the commercially available sodium bromide was found to be high in chloride content. An excess of redistilled bromine was reacted with sodium carbonate solution. The resulting solution was evaporated to dryness and the mixture of sodium bromide and sodium bromate was heated to 550 °C to convert the bromate to bromide. The sodium bromide was then fused by heating in dry nitrogen to about 800 °C in a tube furnace. The iodide and chloride content of this NaBr was found to be less than 0.001 percent.

Three solutions of sodium bromide were prepared in the approximate concentration of the isotope solutions. Five to six samples each containing from 2 to 3 meq. of bromide ion were withdrawn from each solution and analyzed for bromide ion by the described method.

Data resulting from the analyses of these three preliminary bromide solutions showed that: (a) The meq. of bromide ion found by this method agreed to within 0.1 percent of the meq. calculated, and the assayed percentages were independent of sample size and concentration; and (b) The analyses of the three solutions were of equal precision.

The results of the bromide analyses of the separated isotope solutions are shown in table 1a for Groups I and table 1b for Groups II. Pooling the results of these four sets of analyses with the three described above yields a value of 4.74×10−5 meq. Br/g solution as the standard deviation for an individual determination (27 degrees of freedom). The standard error of the mean of four determinations is therefore 2.37×10 −5meq. Br/g solution and that of five determinations is 2.12×10−5meq. Br/g solution.

Table 1a.

Groups I

Sample No. Wt. Sol Bromide Cone Br
Concentration of bromide ion in NaBr79 solution
g meq. meq. Br/g Sol
A 7.53019 2. 56406 0.340504
B 8.21278 2. 79583 . 340424
C 8.54475 2. 90845 . 340379
D 8.26555 2.81273 .340296
E 7.77453 2.64618 . 340365
Mean a. 340394
Concentration of bromide ion in NaBr81 solution
A 9. 09645 2. 97587 0.327146
B 8. 65398 2.83156 . 327197
C 8. 07874 2.64328 . 327190
D 7. 81712 2.55753 .327170
Mean a.327176
a

The standard error of the mean is estimated to be 0.000024 meq/g sol. for the group with four analyses and 0.000021 for the group with five analyses, based on seven groups of data including the sets shown here.

Table 1b.

Groups II

Sample No. Wt. Sol Bromide Cone Br
Concentration of bromide ion in NaBr79 solution
g meq. meq. Br/g Sol
A 7.77112 2. 810027 0.361599
B 7.88535 2.851350 .361601
C 7.32444 2.648832 .361643
D 7. 73096 2.795487 .361596
Mean a. 361610
Concentration of bromide ion in NaBr81 solution
A 7. 78525 2.74700 0. 352847
C 7. 78655 2.67682 . 352838
D 7. 09924 2. 50502 . 352857
E 7.47154 2.63715 . 352959
Mean a. 352875
a

The standard error of the mean is estimated to be 0.000024 meq/g sol. based on seven groups of data including the sets shown here.

2.4. Isotopic Analyses of the Solutions of the Separated Isotopes

To avoid memory problems, one of the two solutions of the separated isotopes was analyzed on one mass spectrometer and the other solution on the other mass spectrometer. The sources were dismantled and thoroughly cleaned before and after each series of measurements. Blank analyses showed that clean sources yielded no bromine signals.

The isotopic compositions of the separated isotope solutions are given in table 2. The respective Br79 and Br81isotopic compositions as reported by ORNL are: “Br79”, 99.74 ±0.02 atom percent Br79, 0.26 ±0.02 atom percent Br81; “Br81”, 0.38 ±0.02 atom percent Br79, 99.62 ±0.02 atom percent Br81. The ORNL limits quoted express the precision of the measurements. From known sources of systematic error, the absolute error is estimated by ORNL to be less than 1 percent.

Table 2.

Isotopic composition of separated bromine isotopes used in calibration samples

Isotope Isotopic composition a (atom %)
Br79 Br79=99.736
Br81 = 0.264 ±0.008
Br81 Br79= 0.386 ±0.008
Br81 = 99.614
a

The limits express the maximum uncertainty as estimated from tbe 95 percent confidence limits of the mass spectrometric determinations and possible errors in the correction factors.

2.5. Preparation of the Calibration Samples

Six calibration samples were originally prepared (group I), but the results of sample No. 2 were subsequently discarded when the mass spectrometric data did not conform to the general pattern. In view of this it was considered desirable to prepare a completely new set of six calibration samples (group II).

All calibration samples were prepared by mixing portions of the Br79 and Br81 solutions, which were withdrawn and weighed in the manner already described. The ratios of Br79/Br81 ranged from 1.01 to 1.04 for group I and 0.94 to 1.13 for group II. For each determination, the portions for the calibration samples and the samples for the determination of the bromide concentration were withdrawn on the same day with the exception of sample E of the Br79 solution of group I and sample E of the Br81 solution of group II which were withdrawn two days after the rest of the group.

Each calibration sample was thoroughly mixed by stirring and 0.5 ml of nitric acid was added. Twenty milliliters of 0.1NAgNO3solution were added to precipitate the bromide as silver bromide and the solution was allowed to stand overnight in the dark. The solution was filtered through filter paper and the precipitate of silver bromide was washed with dilute (1:500) nitric acid. The paper was carefully folded over the precipitate and both were dried in an electric oven at 110 °C. A weighed portion of the silver bromide was then transferred to a 4 ml screwcap vial and sufficient concentrated ammonium hydroxide was added so that the resulting solution contained 3 mg of bromide per milliliter of solution.

The isotopic ratio, μ, of each calibration sample was calculated from

μ=g1(1f1)+g2(1f2)g1f1+g2f2

Where

g1=meq. Br from Br79soln

g2=meq. Br from Br81soln

f1= mole fraction of 81 in Br79soln = 0.00264

(1—f1) =mole fraction of 79 in Br79soln = 0.99736

f2=mole fraction of 81 in Br81soln = 0.99614

(1—f2)=mole fraction of 79 in Br81soln = 0.00386.

The values of g and μ are tabulated in table 3a for group I and in table 3b for group II.

Table 3a.

Group I—composition of calibration samples

Calibration sample No. NaBr79 solution NaBr81 solution Isotopic ratio
meq. Br meq. Br
wt sol g1 wt sol g1 μ
1 2.20305 0. 749905 2.23035 0.729717 1.03000
3 2.03553 .692882 2. 08166 .681069 1.01972
4 2.07995 . 708003 2.11262 .691199 1.02666
5 2.11338 .719382 2.11904 .693299 1. 03992
6 2.17520 . 740425 2.24607 .734860 1. 00999

Table 3b.

Group II—composition of calibration samples

Calibration sample No. NaBr79 solution NaBr81 solution Isotopic ratio
meq. Br meq. Br
wt sol g1 wt sol g1 μ
1 1.04618 0.378309 1. 08450 0.382693 0.99104
2 1.09963 .397637 1. 09671 .387002 1.02982
3 1.09990 .397735 1.10046 .388325 1.02658
4 1.09030 .394263 1. 09721 .387178 1.02068
5 1.18382 .428081 1. 07291 .378603 1.13256
6 1.10534 .399702 1. 20550 . 425391 . 94230

2.6. Isotopic Analyses of the Calibration Samples

Although the bromine background signals were completely negligible during the analyses of natural samples, slight memory effects became evident during the analyses of the calibration samples. These samples were run alternatingly with the reference sample and memory effects on the order of 0.2 percent were evident when the calibration sample differed by 10 percent from the reference. To eliminate memory, a uranium sample was run before and after every sample that differed from the reference by more than 1 percent. The very high temperature achieved during the uranium runs served to remove any bromine from the previous analysis.

2.7. Natural and Commercial Samples

The reference sample is a commercial sample of sodium bromide designated as NBS Isotopic Reference Sample No. 106. A portion of this sample was converted to silver bromide in the same manner as the calibration samples.

The samples of commercial bromine were reacted with ammonium hydroxide solution and converted to silver bromide in the same manner as the calibration samples after making the solutions acidic with nitric acid.

The sylvites (KCl), carnallites (KMgCl3.6H2O), brines, sea water, and bittern were treated as follows: A measured quantity was dissolved in 500 ml of H2O and 1 ml of nitric acid was added. The solution was transferred to a distilling apparatus and, to remove iodine, 50 ml of the solution was distilled into dilute ammonium hydroxide solution. Seventy-five milliliters of nitric acid were then added and the bromine produced was distilled into dilute ammonium hydroxide. Since chloride was the dominant halide in these samples, it was necessary to repeat the oxidation and distillation to free the bromine from chlorine. The bromide concentration in most of these samples ranged from 0.01 percent to 0.1 percent. After the second distillation, the solution was made acidic with nitric acid, converted to silver bromide, and the bromide ion concentration adjusted to 3 mg Br/ml, as in the case of the calibration samples.

The bromyrite sample (AgBr) was dissolved in ammonium hydroxide and the silver was electrodeposited onto a platinum gauze electrode. The solution was made acidic and treated as the above minerals.

3. Results and Discussion

Table 4 compares the calculated isotopic ratios of 11 calibration samples with the results obtained on the two mass spectrometers. Two groups of calibration samples were prepared and the sources of both instruments were dismantled and cleaned between the analyses of the two groups. Table 5 shows the results of multiple analyses of the reference sample (12 per mass spectrometer per determination), both uncorrected and corrected for the biases indicated by the calibration samples. The reasons for the differences in bias cannot be quantitatively evaluated, but the major effect appears to be due to slight changes in the alinements of the source parts when they are reassembled after cleaning. In any case, the excellent agreement between all four corrected values of the reference indicates that the calibration method is consistent.

Table 4.

Determination of mass spectrometric bias

Calibration sample No. Isotopic ratio, Br79/Br81 Correction factor (calc/M.S.)
Calc. MS-1 MS-4 MS-1 MS-4
Group I
1 1.03000 1.02970 1. 03035 1. 000301 0.999670
3 1.01972 1.02055 1. 02120 0.999197 .998561
4 1.02666 1.02820 1.02865 . 998512 .998075
5 1.03992 1. 04105 1. 04125 .998915 .998723
6 1.00999 1.01175 1. 01235 . 998270 .997679
Mean .9990390 .9985416
Group II
1 0.99104 0.99115 0. 99270 0.999899 0. 998328
2 1.02982 1.02960 1. 03225 1. 000214 .997646
3 1.02658 1. 02735 1. 02875 0. 999260 .997900
4 1.02068 1.02125 1. 02270 . 999442 .998025
5 1.13256 1.13185 1.13425 1. 000627 .998510
6 0. 94230 0.94185 0. 94355 1. 000478 .998675
Mean . 9999866 .9981807

Table 5.

Observed and corrected values of the Br79/Br8l ratio for the reference sample

Observed ratio Correction factor Corrected ratio
Group I MS-1 1.028792 0.9990390 1.027807
    MS-4 1. 029592 .9985416 1.028090
Group II MS-1 1. 027683 .9999866 1.027669
    MS-4 1.029675 .9981807 1. 027803
Mean 1.02784 ±0.00105a
a

Uncertainty components:

95 percent confidence limits on ratio determination ±0. 00051

Possible error in composition of separated isotopes ±0.00033

Possible error in calibration sampies ± 0.00021

Table 6 summarizes the bromine isotopic-ratio measurements of samples of commercial bromine and the original bromine source material as supplied by seven major bromine manufacturers in the United States. Table 7 summarizes the results of measurements on a number of mineral samples. The results show that there are no significant isotopic variations among any of the commercial and natural samples. The average Br79/Br81 ratio of the 29 samples is displaced from the reference by—0.00048. Most of this shift is due to the mineral samples which yield the lowest ratios. This result is consistent with previous experience at this laboratory on other elements. 11 may be attributed to a difference in purity between the mineral samples and the reference. In general it is more difficult to obtain standard intensity levels during mass spectrometric analyses of natural samples as compared to reference samples [1] and it was observed that the Br79/Br81 ratios obtained in the more difficult (higher filament temperature) analyses were consistently lower than those obtained in the less difficult (lower filament temperature) analyses.

Table 6.

Isotopic abundance ratios of bromine from various commercial bromine and bromine source materials relative to reference sample

Sample Source Average observed ratio of ratios a
Brine, Searles Lake American Potash & Chemical Corp 0.9988
Brine Arkansas Chemical Co .9996
Bromine Arkansas Chemical Co .9995
Monroe brine Dow Chemical Co .9994
Midland bromine, purified Dow Chemical Co .9998
Freeport bromine, purified Dow Chemical Co .9995
See Water Ethyl-Dow Chemical Co .9992
Bittern F. M. C. Corp .9994
Bromine F. M. C. Corp .9990
Brine Great Lakes Chemical Corp .9999
Brine Great Lakes Chemical Corp .9998
Brine Great Lakes Chemical Corp 1.0005
Brine Great Lakes Chemical Corp 0. 9998
Bromine Great Lakes Chemical Corp .9999
Bromine Great Lakes Chemical Corp .9998
Bromine Great Lakes Chemical Corp 1.0002
Bromine Great Lakes Chemical Corp 0. 9998
Brine, St. Louis production M ichigan Chemical Corp 1. 0002
Bromine, St. Louis production Michigan Chemical Corp 1.0000
Bromine, Manistic production_ Michigan Chemical Corp 0. 9994
Bromine, El Dorado production Michigan Chemical Corp .9992
a

(Br79/Br81) sample/(Br79/Br81) reference. The 95 percent confidence limit is ±0.0012.

Table 7.

Isotopic abundance ratios of bromine from some minerals relative to reference sample

Sample No. a Description Average observed ratio of ratios b
62416 Carnallite, Stassfurt, Germany 0.9992
98011 Carnallite, Barcellona, Spain .9990
106869 Carnallite, New Mexico .9997
103518 c Sylvite, Nebra, Germany .9990
103518 c Sylvite, Nebra, Germany .9988
92665 Sylvite, New Mexico .9995
93472 Sylvite, Kalusz, Galecia, Poland .9993
80263 Bromyrite, Broken Hill, Australia .9990
a

U.S. National Museum Catalog numbers.

b

(Br79/Br81) sample/(Br79/Br81) reference. The 95 percent confidence limit is ±0.0012.

c

Two pieces from the same sample.

The possibility of slight isotopic fractionation during the extraction of the trace amounts of bromine in the natural samples cannot be completely discarded, but is considered extremely unlikely in view of the high recovery techniques used.

A term to cover a possible natura] variation of ±0.00085 (the range of results for the natural samples) in the Br79/Br81 ratio has been included in the error attached to the final atomic weight value (tables 8 and 9).

Table 8.—

Summary calculation of the atomic weight of bromine

Absolute isotopic ratio Br79/Br81=1.02784 ±0.00190 a
Absolute isotopic composition, Atom percent    Br79=50.686 ±0.047 a
   Br81 =49.314 ±0.047 a
Nuclidic masses (C12=12)    Br79=78.918348 ±0.000019 b
   Br81 =80.916344 ±0.000037 b
Unified atomic weight (C12=12)     = 79.90363 ±0.00092
Uncertainty components:
  Reference ratio determination     = ±0.00025
   Composition of separated isotopes     = ±.00016
   Composition of calibration samples     = ±.00010
   Possible natural variations     = ±.00041
   Total     = ±.00092
a

The uncertainties are overall limits of error based on 95 percent confidence limits for the mean and allowances for the effects of known sources of possible systematic error (See table 5) plus a component (.00085, in the ratio) to cover possible natural variations in the Br79/Br81 ratio.

b

From ref. [16].

Table 9.—

Summary of National Bureau of Standards mass spectrometric atomic weight determinations (C12=12) of silver, chlorine and bromine

Element Absolute isotopic ratio Nuclidic mass a Atomic weight
Ag b Ag107/Ag109=1.07597 ±0.00135 Ag107=106.904970 ±0.000110 107.8682 ±0.0010
Ag109= 108.904700 ±0.000110
Cl c Cl35/Cl35 =3.1272 +0.0079–0.0082 Cl35 = 34.9688545 ±0.0000028 35.45273 +0.00092 −0.00097
Cl37 = 36.9658959 ±0.0000022
Br Br79/Br81 =1.02784 ±0.00190 Br79 = 78.918348 ±0.000019 79.90363 ±0.00092
Br81= 80.916344 ±0.000037

Calculated combining weight ratios: Ag Cl/Ag 1.328667 Ag Br/Ag 1.740752

a

See reference [16].

b

See reference [1].

c

See reference [2].

The absolute ratio, Br79/Br81 = 1.0274 ±0.00105, for the refererence sample results in the percentage abundances: Br79=50.686 ±0.025 and Br81=49.314±0.025. The uncertainties are the sum of the 95 percent confidence limits on the ratio determination and the estimated maximum possible errors in the analyses of the separated isotopes and the compositions of the calibration samples. Using the nuclidic masses given by Everling et al. [16], the results yield an atomic weight of 79.90363 ±0.00051 on the unified scale (C12=12). These calculations are summarized in table 8 where the error statements include the effect of possible natural variation to the extent noted previously.

The atomic weight of bromine reported here is significantly different from that accepted by the International Commission on Atomic Weights (1961), 79.909 ±0.002 (C12=12), which was derived by the use of a combining weight for AgBr/Ag= 1.740785 and the Commission’s value of 107.870 for the atomic weight of silver. Using the herein determined value of 79.90363 for bromine and the silver value of 107.8682 from Shields et al.[1] gives a combining weight ratio AgBr/Ag =1.740752. Table 9 summarizes the atomic weight results on silver, chlorine and bromine obtained in this laboratory using the same mass spectrometers and the same calibration technique. Also shown are the calculated combining weight ratios of AgCl/Ag and AgBr/Ag.

Acknowledgments

The authors are indebted to George Marinenko for the coulometric titrations of the bromide in the separated isotope solutions and to Hsein H. Ku for the statistical analysis of the experimental data. They also express their appreciation to Dr. George Switzer and the U. S. National Museum for supplying the mineral samples and to the following companies for supplying the bromine and brine samples: American Potash & Chemical Corp., Los Angeles, Calif.; Arkansas Chemicals, Inc., El Dorado, Ark.; The Dow Chemical Co., Midland, Mich.; Ethyl-Dow Chemical Co., Freeport, Tex.; F. M. C. Corporation, Newark, Calif.; Great Lakes Chemical Corp., Filer City, Mich.; Michigan Chemical Corp., Saint Louis, Mich.

Footnotes

1

Figures in brackets indicate the literature references at the end of this paper.

2

Overall limit of error based on 95 percent confidence limits for the mean and allowances for effects of known sources of possible systematic error.

4. References

  • [1].Shields W. R., Garner E. L., and Dibeler V. H., J. Res. NBS 66A (Phys. and Chem.), 1 (1962). [Google Scholar]
  • [2].Shields W. R., Murphy T. J., Garner E. L., and Dibeler V. H., J. Am. Chem. Soc. 84, 1519 (1962). [Google Scholar]
  • [3].Blewett J. P., Phys. Rev. 49,900 (1936). [Google Scholar]
  • [4].Williams D. and Yuster P., Phys. Rev. 69, 556 (1946). [Google Scholar]
  • [5].White J. R. and Cameron A. E., Phys. Rev. 74, 991 (1948). [Google Scholar]
  • [6].Cameron A. E. and Lippert E. L. Jr., Science 121,136 (1955). [DOI] [PubMed] [Google Scholar]
  • [7].Hillebrand W. F., Lundell G. E. F. II. Bright A., and Hoffman J. I., Applied Inorganic Analysis, 2d ed., p. 726 (John Wiley & Sons, New York, N.Y., 1953). [Google Scholar]
  • [8].Murphy T. J.,Clabaugh W.S., and Gilchrist R., J. Res. NBS 53, 13 (1954). [Google Scholar]
  • [9].Abel E., Monatsh.81,339 (1950). [Google Scholar]
  • [10].Masson O., J. Chem. Soc. 91,1449 (1907). [Google Scholar]
  • [11].Schuster F., Z. anorg. allgem. Chem. 186,253 (1930). [Google Scholar]
  • [12].Halfpenny E. and Robinson P. L., J. Chem. Soc. 1952,928. [Google Scholar]
  • [13].Uzel R., Coll. Czech. Chem. Commun. 5, 139 (1933). [Google Scholar]
  • [14].Allen N., Ind. Eng. Chem., Anal. Ed. 2, 55 (1930). [Google Scholar]
  • [15].Marinenko G. and Taylor J. K., J. Res. NBS 67A(Phys.and Chem.), 31 (1963). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [16].Everling F., König L. A., J. H. E., Mattauch, and Wapstra A. H., Nuclear Phys. 18, 529 (1960). [Google Scholar]

Articles from Journal of Research of the National Bureau of Standards. Section A, Physics and Chemistry are provided here courtesy of National Institute of Standards and Technology

RESOURCES