Skip to main content
Data in Brief logoLink to Data in Brief
. 2019 Jun 8;25:104114. doi: 10.1016/j.dib.2019.104114

Dataset of various characterizations for novel bio-based plastic poly(benzoxazole-co-benzimidazole) with ultra-low dielectric constant

Aniruddha Nag a,1, Mohammad Asif Ali a,1, Makoto Watanabe a, Maninder Singh a, Kittima Amornwachirabodee a, Shunsuke Kato b, Tetsu Mitsumata b, Kenji Takada a, Tatsuo Kaneko a,
PMCID: PMC6595406  PMID: 31294062

Abstract

The data presented in this specified data article comprise of various characterization such as: structural, thermal, elemental etc. to understand the novel structure and specific properties of the bio-based plastic as described in the main research article “High-performance poly (benzoxazole/benzimidazole)bio-based plastics with ultra-low dielectric constant from 3-amino-4-hydroxybenzoic acid” [1]. The data of 1H NMR spectra of two monomers and their HCl salt formation required for polymerization, FT-IR spectra of polymer formation before and after thermal ring-closing and additionally supported by the thermogravimetric plots where mass loss due to water is observed around 400 °C (thermal ring closing temperature). Solvent plays effective role to change dielectric properties significantly, complete removal of the remaining solvents was confirmed by X-ray photoelectron spectroscopy (XPS) technique. Wide-angle XRD dataset was presented here to make an idea about degree of crystallinity of the prepared polymers.

Keywords: Characterization, High-performance, Polymer, Dielectric


Specifications table

Subject area Chemistry
More specific subject area Bio-based polymer
Type of data NMR, FT-IR spectra, TGA plots, XPS data, XRD plots, sample image
How data was acquired 1H NMR was performed on a ‘BRUKER Biospin AG 400 MHz spectrometer’. FT-IR spectra were recorded with a ‘Perkin-Elmer Spectrum One spectrometer’ between 4000 and 400 cm−1 using a diamond-attenuated total reflection (ATR). Thermo-gravimetric analysis (TGA) was performed on a ‘HITACHI STA7200’. The samples (<5 mg) were placed in a platinum crucible heated to a maximum temperature of 800 °C at a heating rate of 10 °C min−1 under a nitrogen atmosphere. The XRD patterns of the samples were analyzed using X-ray diffraction (RIGAKU Smartlab) operated at 40 kV, 30 mA with Cu-Kα radiation (1.5418 Å). XPS were measured using ‘SHIMADZU KRATOS Axis-Ultra DLD’ instrument.
Data format Raw and analyzed
Experimental factors 1H NMR was performed using DMSO-d6 as solvent at 23.1 °C. FT-IR spectra were recorded using powder. In case of TGA to observe thermal ring closing behavior we have pre-heated the sample which is designated as PBI-co-PBI, in case of pre-(PBO-co-PBI) no pre-heating was done. Polymer powder was used in both the cases of XPS and XRD analysis.
Experimental features Various compositions of pre-PBO-co-PBI were obtained using 3-amino-4-hydroxybenzoic acid (3, 4-AHBA) and 3, 4-diaminobenzoic acid (3, 4-DABA) in different compositions. PBO-co-PBI was obtained by stepwise heating to get completely cyclized oxazole and imidazole rings.
Data source location School of Materials Science, Japan Advanced Institute of Science and Tech-nology (JAIST), 1-1 Asahidai, Nomi-shi, Ishikawa, 923–1292, Japan
36°26′40.3″N, 136°35′33.5″E
36.444528, 136.592639
Data accessibility Data is with this article.
Related research article A. Nag, M. A. Ali, M. Watanabe, M. Singh, K. Amornwachirabodee, S. Kato, T. Mitsumata, K. Takada, T. Kaneko, High-performance poly (benzoxazole/benzimidazole)bio-based plastics with ultra-low dielectric constant from3-amino-4-hydroxybenzoic acid, Polym. Degrad. Stab. 162 (2019), 29–35 [1].
Value of the data
  • The following 1H NMR data are useful to understand the difference between the proton peaks before and after salt formation, which is necessary for polycondensation of both monomer.

  • Understanding of thermal ring closing using via FT-IR spectra and observing weight-loss during thermal cyclisation which comprises water elimination.

  • Elemental analysis using XPS technique is useful to understand presence of trace amount of solvent which can affect the polymer properties in multiple folds.

  • XRD pattern of the copolymer PBO-co-PBI and homopolymers (PBO or PBI) can be useful to refer by other researchers.

1. Data

In 1H NMR spectra (Fig. 1) comparison between monomer 3, 4-AHBA and its salt i.e. 3, 4-AHBA.HCl, the main chain proton signals for aromatic protons appeared between 6.7 and 7.3 ppm, while after salt preparation peak shift occurred and the corresponding proton signals were placed between 7.2 and 8.0 ppm.

Fig. 1.

Fig. 1

1H- NMR spectra of 3, 4-AHBA and 3, 4-AHBA.HCl.

On the other hand, aromatic hydroxyl (-OH) peak position remains same as broad singlet between 9.5 and 10.5 ppm. Aromatic carboxylic acid (-COOH) peak appeared after the salt preparation at 11.6–11.8 ppm.

Fig. 2 shows the 1H NMR spectra comparison between monomer 3, 4-DABA and its salt 3, 4-DABA. 2HCl, where the aromatic proton signals appeared in between 6.4 and 7.2 ppm, while after salt preparation peaks shifted in between 6.7 and 7.5 ppm. More significantly diamine proton peaks clearly observed at 5.2 ppm and disappeared after salt formation, which confirms the diamine salt structure.

Fig. 2.

Fig. 2

1H- NMR spectra of 3,4-DABA and 3,4-DABA.2HCl.

Fig. 3 shows the FT-IR spectra comparison between pre-PBO-co-PBi and PBO-co-PBI.

Fig. 3.

Fig. 3

FT-IR spectra of PBO-co-PBI and its corresponding precursor pre-PBO-co-PBI.

The stretching vibration of pre- PBO-co-PBI spectra shows two peaks for the carbonyl (C Created by potrace 1.16, written by Peter Selinger 2001-2019 O) at 1673 cm−1 (amide I) and 1634 cm−1 (amide II) bands, which were disappeared at 400 °C indicating that PBO-co-PBI has no carbonyl (C Created by potrace 1.16, written by Peter Selinger 2001-2019 O) group available in the structure. However, the absorption band at 1458 cm−1 was directly attributed to the characteristic C Created by potrace 1.16, written by Peter Selinger 2001-2019 C indicates stretching of aromatic bands and other absorption bands observed at 1197 cm−1, and 1140 cm−1 were attributed to the characteristic C–N bonds and –NH2 group were disappeared after thermal cyclization. The distinct characteristic C Created by potrace 1.16, written by Peter Selinger 2001-2019 N and C–N absorption around 1624 cm−1 and 1292 cm−1 were associated to oxazole and imidazole ring [2], [4].

In Fig. 4 thermogravimetric analysis (TGA) plots were shown, comparing between thermally-cyclized and precursor copolymer for a representative case of all the PBO-co-PBIs prepared. Weight-loss was observed between 350 and 400 °C of about 7.8%, certainly due to loss of water molecule as thermal ring closing took place around this temperature range and it was further supported by FT-IR spectra.

Fig. 4.

Fig. 4

Thermogravimetric curves of PBO-co-PBI and its corresponding precursor pre-PBO-co-PBI.

After preparing polymer films using solution casting method, they were washed thoroughly and heated to 400 °C for thermal ring closing, physical texture of the obtained films for all the prepared compositions of PBO-co-PBI are shown in Fig. 5. Presence of benz-azole ring and various functional groups in polymer structure, film became yellow in color and non-transparent.

Fig. 5.

Fig. 5

Polymer Film of PBO-co-PBI with various compositions (PBO/PBI).

In Fig. 6 XPS data was shown for a representative case of PBO-co-PBI where mainly used for elemental analysis of the amount of remaining solvent. Phosphorus and sulfur content in the polymer films depict presence of solvents such as methanesulfonic acid (MSA)/phosphoric acid which can actually affect the physical properties of the polymer. Atomic percentage of phosphorus (0.08%) and sulfur (0.09%) were observed as compared with carbon and oxygen present in the sample [5].

Fig. 6.

Fig. 6

XPS spectra of the polymerized sample to determine elemental analysis.

In Fig. 7 XRD data were shown for the homopolymer (PBO and PBI) and a representative copolymer PBO-co-PBI (60/40) along with their degree of crystallinity, which were calculated quantitatively using the method described by Nara and Komiya et al. [3]. The diffraction curves showed two differential peaks both in the case of homopolymer and copolymers which confirms that copolymerization does not affect over crystallinity.

Fig. 7.

Fig. 7

XRD spectra of PBI and PBO and its copolymers PBO-co-PBI and PBO/PBI (60/40) compositions.

In Table 1, the dielectric data for all the prepared PBO-co-PBIs were presented in tabular form for better understanding and elaborated discussion was already done in the main manuscript. All the data were compared with Kapton™, which is a well-known commercial polymer dielectric material [6].

Table 1.

Dielectric properties for polymers with various PBO/PBI compositions.

Polymers a Film Thickness (μm) εb δvc(Ωcm)(before drying) δvc(Ωcm)(after drying) Dd (kV/mm)
(PBO/PBI) 0/100 19 3.5 1.8 × 108 2.0 × 1012 40.0
20/80 22 3.0 7.9 × 109 7.6 × 1013 41.8
40/60 25 2.8 7.8 × 108 3.4 × 1013 39.6
50/50 24 2.6 1.9 × 109 6.9 × 1013 41.6
60/40 21 2.4 1.3 × 1010 2.3 × 1014 50.5
80/20 23 2.2 1.9 × 1010 1.2 × 1014 63.5
100/0 19 1.9 4.3 × 1010 1.7 × 1015 110.5
Kapton™ 25 3.3 5.1 × 1010 116.0

(a) Polymer films with various (PBO/PBI) compositions were prepared maintaining film thickness 20 ± 5 μm. (b)Dielectric constant, ε, measured at 1 MHz, (c) Resistivity, ϱv, of the films measured at 1 kV of DC electric voltage for 20 s application, (d) Dielectric strength, D, measured with increasing DC electric voltage up to 6 kV by two terminals method with a ramp-up time of 120s.

2. Experimental design, materials and methods

For 1H NMR DMSO-d6 were used as NMR solvent at 23.1 °C with 16 accumulation scans, using proton resonance of residual non-deuterated DMSO as an internal standard (2.55 ppm). PBO-co-PBI powder were obtained by stepwise heating for thermal cyclization up to 400 °C and used for FT-IR analysis within the range between 4000 and 400 cm−1. TGA was performed at a heating rate of 10 °C min−1 under N2 atmosphere and for certain cases preheating were done inside TGA instrument to complete thermal cyclization if required. To analyze TGA data, percentage weight loss calculated from the raw data and plotted against temperature. Polymer films were casted following solvent casting method in trifluoroacetic acid (TFA) with 2–3% of MSA. Thickness of the films was maintained in a range between 20 ± 5 μm as dielectric properties of the polymer depend on thickness. The XRD patterns of the samples were analyzed using X-ray diffraction (Rigaku Smartlab) operated at 40 kV, 30 mA with Cu-Kα radiation (1.5418 Å). For X-ray photoelectron spectroscopy (XPS), the polymer film attached on carbon tape and measurements were performed on a Shimadzu Kratos AXIS-ULTRA DLD high performance XPS system. We checked the elemental presence of C 1s and O 1s with respect to the S 2p and P 2p in terms to check the presence of residual solvents if any and thus purity of the sample.

Acknowledgements

The research was financially supported by Japan Science and Technology, under the project: JST CREST (JPMJCR13B3) and Cross-ministerial Strategic Innovation Promotion Program (SIP), “Smart-bio” (Bio-oriented Technology Research Advancement Institution, NARO).

Conflict of Interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

References

  • 1.Nag A., Ali M.A., Watanabe M., Singh M., Amornwachirabodee K., Kato S., Mitsumata T., Takada K., Kaneko T. High-performance poly(benzoxazole/benzimidazole)bio-based plastics with ultra-low dielectric constant from3-amino-4-hydroxybenzoic acid. Polym. Degrad. Stabil. 2019;162:29–35. doi: 10.1016/j.polymdegradstab.2019.01.036. [DOI] [Google Scholar]
  • 2.Nag A., Ali M.A., Singh A., Vedarajan R., Matsumi N., Kaneko T. N-boronated polybenzimidazole for composite electrolyte design of highly ion conductive pseudo solid-state ion gel electrolytes with high Li-transference number. J. Mater. Chem. A. 2019;7:4459–4468. doi: 10.1039/C8TA10476J. [DOI] [Google Scholar]
  • 3.Nara S., Komiya T. Studies on the relationship between water-satured state and crystallinity by the diffraction method for moistened potato starch. Starch - Stärke. 1983;35:407–410. doi: 10.1002/star.19830351202. [DOI] [Google Scholar]
  • 4.Ali M.A., Shimosegawa H., Nag A., Takada K., Kaneko T. Synthesis of thermotropic polybenzoxazole using 3-amino-4-hydroxybenzoic acid. J. Polym. Res. 2017;24(12):1–7. doi: 10.1007/s10965-017-1362-9. [DOI] [Google Scholar]
  • 5.Baik D., Lee W., Park Y. Interfacial characterization of POLYBENZOXAZOLE/COPPER system. Mol. Cryst. Liq. Cryst. 2004;424:265–271. doi: 10.1080/15421400490506270. [DOI] [Google Scholar]
  • 6.Diwedi S., Sakamoto S., Kato S., Mitsumata T., Kaneko T. Effects of biopolyimide molecular design on their silica hybrids thermo-mechanical, optical and electrical properties. RSC Adv. 2018;8:14009–14016. doi: 10.1039/c8ra01965g. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Data in Brief are provided here courtesy of Elsevier

RESOURCES