Skip to main content
Journal of Research of the National Bureau of Standards. Section A, Physics and Chemistry logoLink to Journal of Research of the National Bureau of Standards. Section A, Physics and Chemistry
. 1965 Nov-Dec;69A(6):495–509. doi: 10.6028/jres.069A.051

Arc Measurement of Some Argon Transition Probabilities

C H Popenoe, J B Shumaker Jr
PMCID: PMC6599100  PMID: 31927825

Abstract

Transition probabilities and line shape parameters for three argon lines have been measured in a wall-stablilized argon arc containing a trace of hydrogen. The Hβ line shape measurement and the assumption of local thermodynamic equilibrium provided the determination of the argon level populations. From these three lines ten other argon line transition probabilities have been obtained by relative measurements in a pure argon arc. The results are compared with those of other investigators and sources of error are discussed.

Keywords: Arc, argon, linewidth, plasma, spectroscopy, stark broadening, transition probability

1. Introduction

The importance of argon transition probabilities for plasma diagnostics is reflected in the large amount of recent experimental work on the measurement of these quantities [1, 2, 3, 4].1 The most fruitful source of these measurements has been the high current thermal arc, but unfortunately even here in similar sources the results of different investigators may differ by factors of two, well outside the error estimates attributed to the measurements by their authors. Consequently an additional attempt to measure argon transition probabilities in a thermal arc source was undertaken. The particular technique employed was one which has previously been used in these laboratories [5]. It consists of operating a wall-stabilized arc with a gas mixture containing a trace of hydrogen in the gas whose transition probability is to be measured, and then deducing the arc plasma temperature and composition from the spectral line shape of the 4861 Å hydrogen Balmer β line. From the plasma composition and absolute line intensity measurements the transition probabilities can be derived.

Absolute transition probabilities were determined in this manner for the two AI lines at 4300 and 6965 Å and for the AII line at 4806 Å. These lines were selected for their prominence, isolation from their neighbors, symmetry, relative freedom from self absorption, and location in wavelength regions favorable for photoelectric detection. Some additional transition probabilities were measured relative to one or another of these three reference lines in pure argon arcs. However, measurements on these lines are less satisfactory either because the lines are weak or because of ambiguity in the location of the background. Most of the prominent blue argon lines in this source are afflicted with this background problem due to the closeness of strong neighbors or asymmetric line shapes (see fig. 1) either of which can result in an uncertainty in the total intensity to be ascribed to the lines.

Figure 1. Atmospheric pressure argon arc spectra after Abel inversion [ref. 19].

Figure 1.

The total intensity of AI 4300 Å yields an electron density of 6.9 × 1016 cm−3 and temperature of 12 060 °K assuming the transition probability value of table 3.

All of the data recording, handling, and calculations including the graphical presentation of the results were done by automatic machine methods to eliminate as many sources of error as possible. With the statistically large samples made possible by these methods along with elimination of subjective measurements and increased precision, it becomes possible to attempt a more thorough analysis of the errors and uncertainties involved in these measurements.

2. Experimental Details

2.1. Light Source

The radiation source is a wall-stabilized or cascade d-c arc of about 10 cm length and 5 mm diam. The arc chamber is similar to that described in reference [6] with the exception of improved water cooling for higher current operation. The graphite electrodes are surrounded by a separate flow of argon, preventing rapid electrode erosion and contamination of the test gas in the observation section. After passing through the arc the gases are exhausted to the atmosphere through large diameter ports. The arc characteristically operates stably for long periods of time for most test gases. For the experiments reported here arc currents of 40, 60, and 90 A were used.

The arc chamber is mounted on a carriage movable by means of a lead screw in a direction transverse to the optic axis of the monochromator. An electrically actuated single-revolution clutch couples an electric motor to the leadscrew drive providing for either continuous or incremental movement of the arc carriage. Variation in rate of scan or increment size is accomplished by a set of quick-change gears in the drive train.

Electrical power is supplied to the arc by either a bank of 100 6 V storage batteries, or a rotary converter of 500 kVA capacity and 650 V output as shown schematically in figure 2. Both power sources were used during this series of experiments with no observable difference in results. The voltage drop across the arc is typically 102 V in argon at 60 A, and 112 V with 1 percent hydrogen added to the test gas. The bulk of the power is dissipated in a large variable water resistor [7] in series with the arc supply.

Figure 2.

Figure 2.

Arc circuit schematic including some details of the transistorized automatic current regulator.

The current is automatically regulated by a solid-state series current regulator (see fig. 2) consisting of 30 power transistors in parallel, with the current error signal being derived from a 0.2 Ω oil-cooled manganin shunt. The arc current is initially set and later monitored with a potentiometer and galvanometer by which variations in total arc current as small as 1 mA may be observed. A carbon pile rheostat is used to provide vernier adjustment of the ballast resistance.

2.2. Optical and Spectrographic Arrangement

The arc was viewed in a plane perpendicular to the arc axis with the image focused slightly enlarged on the monochromator entrance slit. A rectangular diaphragm opening at the lens formed the aperture stop of the system and limited the solid angle from the arc to 0.002 sr. The dispersing element was an 0.8 m Ebert-Fastie plane grating monochromator having a nominal dispersion of 10 Å/mm in the first order. Entrance and exit slits of 15 μ width were used in most of the experiments. The entrance slit height was masked to 1.2 mm to eliminate reflections from the copper plates adjacent to the observation section of the arc chamber and to minimize the effect of any slight variations of the arc column along its length. During the course of the experiments, RCA 931A (S-4 response), Hamamatsu R-136 and RCA 7265 (S-20 response), and ITT FW-118 (S-l response) photomultiplier tubes were employed to detect the spectral intensity.

The monochromator grating drive is fitted with a single channel paper tape reader attached directly to the wavelength counter to allow direct digital control of the wavelength setting. An electrical signal causes the monochromator to scan in wavelength until a punched hole in the paper tape is sensed by the reader. A program paper tape may therefore be punched to direct the monochromator through a prescribed, not necessarily evenly spaced sequence of wavelengths in the spectrum. The resolution of the tape reader is 0.05 Å and the precision of the wavelength setting better than 0.01 Å.

2.3. Data Recording and Control System

The large quantity of data encountered in spectrometric studies involving spacial resolution of plasma characteristics invites the use of automatic digital techniques for data collection and reduction [8]. To facilitate data handling the response of the monochromator was recorded digitally on punched paper tape in a form compatible with electronic data processing equipment. In addition, the monochromator wavelength drive and arc carriage positioning mechanism were automatically actuated and coordinated so as to perform the proper variable changes during an experiment in the minimum time.

In essence, the data recorder consists of amplifying, digitizing and tape punching equipment. The small current output of the photomultiplier is amplified and converted to a voltage signal of the order of 1 V which in turn is converted to a pulse train whose frequency is proportional to this voltage. An electronic counter sums the pulses for a precise interval of time, resulting in a digitized integral of the applied voltage over the counting interval. Upon command, six digits of information from the counter are loaded simultaneously into a shift register from which they may be shifted out serially into a code-conversion matrix and punched on paper tape in binary-coded-decimal form.

Movement of the arc carriage, changes in the monochromator wavelength and recording of photomultiplier current are all directed and coordinated automatically during a run by a central programmer. The heart of the programmer is a 25-step, 11 level stepping switch, wired in a closed-loop mode; i.e., a signal from the preceding operation verifying its successful completion is necessary to initiate a succeeding operation. With the above system the rate of data recording is limited by the tape punch to about two 8-character data points per second.

The possibility of erroneous recordings is greatly diminished by various self-checks incorporated into the system. The analog section of the system (current amplifier and voltage-to-frequency converter) is subject to the small errors inherent in analog devices and is therefore checked and calibrated several times during an experiment. The calibration is transferred directly to punched tape to preclude errors in recording. The nature of the digital section, and indeed of digital systems in general is such that the occurrence of small errors in transferring digits through the system is highly improbable. To ensure that such errors, if they occur, will be detected, an odd-bit parity check is made at the tape punch, and the recording process is automatically stopped if an added or dropped bit is detected on the tape. A second and independent parity check is made during the process of converting the tape to punched cards.

2.4. Experimental Method

A representative spectral line measurement consisted of the photoelectric recording of the arc intensity at each of perhaps 30 equally spaced positions across the width of the arc. This set of measurements was then repeated at each of usually 27 wavelengths spaced nonuniformly across the spectral line—spanning altogether about 10 times the maximum full halfwidth of the line. Finally, without turning off the electronics, recordings were made of the intensity of a calibrated tungsten strip pyrometer lamp at the same 27 wavelengths.

An intermittent arc traversing technique was used in which the motion of the arc carriage was momentarily stopped for an interval of time sufficient to overcome photomultiplier delay effects and to record the intensity at that point before resuming motion and proceeding to the next point. This eliminates the distortion of the arc profile which results from continuous movement of the arc carriage during the counting interval. Also, since the traverses always begin at precisely the same point (±0.001 cm), each recorded point corresponds to a given point in space referenced to a laboratory coordinate system, not a function of time or scanning rate. The recording positions are therefore repeatable and the recorded intensities directly comparable from traverse to traverse.

The effect of integrating the intensity at a point for a finite interval of time is a temporal smoothing of noise at that point on the arc profile. Some further spacial smoothing occurs because of the necessity of observing a finite “slice” of the arc column. However, the additional loss of spacial resolution which would result from a continuous traversing or “scanning” of the arc image is effectively avoided by the intermittent traversing technique. In these experiments an integrating period of 0.1 sec was used. The width of the observed “slice” was determined by the slit width and in most experiments amounted to about 0.001 cm while the distance between samples was typically 0.03 cm.

The test gas—either pure argon or premixed mixture of argon and 1 percent hydrogen—was injected tangentially into the arc on both sides of the observation chamber at a rate of 1.2 liter/min and a differential pressure of a few millimeters of water. Gas flow rates were monitored by flow meters and adjusted to minimize flow in the observation chamber. Separate flows of pure argon at about 0.2 liter/min were injected tangentially at the electrodes. The difference in flow rates insured a net gas flow away from the observation section, further precluding electrode vapor contamination by diffusion.

The intensity measurements are calibrated with a tungsten strip lamp at a brightness temperature at 6530 Å of 2340.3 °K (IPTS 1948). The lamp was periodically calibrated by the Temperature Physics Section of the National Bureau of Standards. At the conclusion of each arc experiment it was placed at the arc position with the quartz window from the arc placed in the optic path to eliminate the necessity for determination of window transmission. A well-regulated d-c power supply maintained the strip lamp current at a constant level within 0.01 percent. The same punched program tape used to direct the mono-chromator through the sequence of wavelengths for the experiment was then used to record the calibrated strip lamp intensity at the same wavelengths as those of the experiment.

3. Treatment of Data

3.1. Abel Inversion

In order to obtain the radial distribution of volume emission in the arc from side-on measurements it is necessary to solve the appropriate Abel integral equation [9] for each traverse across the arc. The technique employed is based upon one described by Freeman and Katz [10] in which the distribution of measured side-on intensities is fitted by a polynomial in the positional coordinate with origin at the center of symmetry. The solution of the integral equation is then obtained analytically for this polynomial and the volume emission at any desired point in the arc is calculated from this solution. By including odd powers in the fitting polynomial some minimal allowance is made for source asymmetry and for errors in locating the position of the arc “center of symmetry” [11].

The polynomial fitting was accomplished by the use of the orthogonal properties of the Jacobi [12] polynomials Pn(a,a)(x/R) whose inverse Abel transform is expressible in terms of Pn(a1/2,0)(2[r/R]21) with odd n terms treated in the approximation of Freeman and Katz [11]. R is the distance from the arc center beyond which the intensity is considered negligible. This technique results in the weighting of the data points by (1 — [x/R]2)a. In the experiments reported here uniform weighting (a=0) was arbitrarily used after experiments revealed no appreciable difference in the results obtained using a=0 (corresponding essentially to the Freeman and Katz method) and a=12 (corresponding, except for the odd n terms, to a method described by Herlitz [13]). Individual arc traverses contained from 20 to 41 measurements at equally spaced x points and the resulting intensity profiles were fitted by the Jacobi polynomial expansions with 8 to 12 terms.

3.2. Line Shape Parameters

The volume emission intensities calculated from the Abel inversions were reassembled as a function of wavelength at each radial point and a suitable theoretical spectral line shape was fitted by an iterative least squares technique. In the case of the argon lines a dispersion (Lorentz) shape superimposed upon a linear background was used as the fitting function:

I=A+B(λλ0)+C1+[(λλ0)/Δ]2

with A, B, C, λ0, and Δ being adjusted to minimize the sum of the squares of the residuals. In the case of the hydrogen β lines the line shape fitting was preceded by subtracting from each experimental Abel inverted wavelength scan the corresponding pure argon arc spectrum at the same radial point. This pure argon background spectrum was obtained as a part of each experiment in the same manner and under the same arc conditions as was the argon-hydrogen mixture data. The red and blue wings of the resulting difference spectrum were then averaged and this line shape was fitted to an appropriate theoretical Hβ line shape:

I=A+BS(α)

where α=1.25×10−9|λ−λ0|(Ne)−2/3, S(α) is a theoretical line shape [14], and A, B, and the electron density Ne(cm−3) are adjusted to minimize the residual function. The Griem, Kolb, and Shen tabulations of S(α) were fitted piecewise by cubics in all the tabulated intervals except the first where a parabola was used with the condition dSdα=0 at α=0. The asymptotic wing formulas [15] were used beyond the range of the tables. In this manner piecewise analytic approximations to S(α) were constructed for Hβ. In addition to the dependence of the Hβ line shapes upon Ne implied by the definition of α, there is a further weak dependence upon Ne and T. This dependence was included in these calculations by the actual use of different piecewise line shapes calculated for Ne=1017 and T=13 000 °K, Ne=1016 and T=10 000 °K, and for Ne=1015 and T=7500 °K-the first and last being obtained by interpolation in the Griem, Kolb, and Shen tables.

All of the above calculations as well as division by the strip lamp calibration data and conversion to absolute intensities are programmed to be performed in one pass through the IBM 7094 digital computer. At each radial point the computer plots the experimental radially-resolved wavelength scans and tabulates all of the line fitting parameters; in particular the argon line centers λ0, 12-halfwidths Δ, and total intensities πCΔ, the hydrogen line total intensity B∫S(α)dα, and the electron density Ne.

No slit width corrections were necessary for the hydrogen lines because of their relatively great width. However, for the argon lines slit or apparatus function corrections were required. For this purpose the program for dispersion line shape fitting was systematically calibrated using various ratios of apparatus function width to dispersion line width and using various distributions of wavelength points of measurement across the line. The calibration was done for both Gaussian and triangular apparatus functions and resulted in the application of small slit width dependent corrections to the computed line widths and, for very wide slits, to the line intensities. This procedure should be quite reliable for lines which have nearly a dispersion shape.

The apparatus functions observed with the 15 μ entrance and exit slits used in most of these experiments were approximately Gaussian with 12-halfwidths (one-half of the full width at the half maximum intensity level) of 0.1 Å. One experiment was performed with 150 μ slits in which the apparatus function was nearly triangular with a 12-halfwidth of 0.75 Å.

Examples of the line shape fitting are given in figures 3 and 4. The AI 4300 Å line can be seen to exhibit some skewness. This skewness together with the unsymmetric disposition of the wavelength points2 causes the dispersion shape fitting routine to produce a line shape which in this example is about 3 percent narrower than a good eye-fit would probably yield. The apparatus function for both lines in this example was the Gaussian shape with 12-halfwidth of 0.1 Å. In figure 3 the computer-fitted 12-halfwidth of 0.771 Å required a correction of 0.013 Å for apparatus function resulting in an estimate of 0.758 Å for the 12-halfwidth of the spectral line itself. In figure 4 the intensity scale for Hβ is displaced vertically by an amount which has no particular physical significance being determined by the subtracted hydrogen-free background spectrum.

Figure 3.

Figure 3.

Experimental intensity points in the neighborhood of AI 4300 Å after Abel inversion (0.13 cm from axis of 90 ampere arc in argon with ∼1% H2) showing computer fitted background and dispersion shape: ½-halfwidth=0.771 Å, total line emission= 9.44 × 1017 photons cm−3 sec−1

Figure 4.

Figure 4.

Experimental intensity points in the neighborhood of Hβ 4861 Å after Abel inversion (same conditions as fig. 3) shoiving computer fitted background level and theoretical line shape: electron density = 7.45 × 1016 cm−3, total line emission = 8.10 × 1018 photons cm−3 sec−1.

Beyond a radial distance of 0.2-.25 cm, the line shape fitting procedure was considered unreliable due to the sharpness of the lines and the attendent small number of points defining their shapes. At these distances, the low number density of the emitting species causes a reduction in the signal/noise ratio with the effect that the determination of the true line shape from a statistically small sample of noisy data is improbable. For these reasons, the data from regions lying beyond an arbitrarily chosen radial distance of 0.2 cm (0.16 cm for ionic lines) is not reported here.

Argon line shifts and 12-halfwidths corrected for the 0.1 Å Gaussian apparatus function are plotted in figures 5 to 10 against the electron density as determined from the Hβ line shapes. The wavelengths for the unshifted lines were obtained by extrapolation to Ne=0. Both the widths and shifts are seen to be approximately proportional to the electron density in rough agreement with theory [9]. The proportionality constants obtained by least squares fitting of this data are shown in table 1.

Figure 5.

Figure 5.

dependence of 12-halfwidth upon electron density for AI 4300 Å.

Figure 10.

Figure 10.

Dependence of the blue shift of the AII 4806 Å line upon electron density.

Table 1.

Stark 12-half widths, w, and shifts, d, for argon lines

Line wNe×1016 [Å cm3] dNe×1016 [Å cm3]*
Expt. Theor. Expt. Theor.
AI 4300 Å 0.100 0.124 0.103 0.132
AI 6965 Å .048 .061 .039 .079
AII 4806 Å .0148 .0058 −.0073 (−.0022)
*

Shifts to the red are taken as positive.

Figure 6.

Figure 6.

Dependence of the red shift of the AI 4300 Å line upon electron density.

Figure 7.

Figure 7.

Dependence of 12-halfwidth upon electron density for AI 6965 Å

Figure 8.

Figure 8.

Dependence of the red shift of the AI 6965 Å line upon electron density.

Figure 9.

Figure 9.

Dependence of 12-halfwidth upon electron density for AII 4806 Å.

3.3. Transition Probabilities

The calculation of the argon transition probabilities requires a knowledge of the plasma composition at each arc data point. For conditions of local thermo-dynamic equilibrium this can be computed in principle from the total pressure (1 atm), measured electron density, and total Hβ line intensity assuming that only hydrogen and argon are present and using the theoretical Hβ. transition probability, Dalton’s law, the condition for quasi-neutrality and the appropariate mass action laws (Saha equations) for the possible ionization and dissociation reactions. The fact that the hydrogen was present in trace amounts permitted some simplification of the calculations as has been discussed previously [5, 16]. This simplified calculation requires a table of the composition of a pure argon plasma at atmospheric pressure and employs small corrections computed iteratively from the observed Hβ line intensity.

The pure argon plasma composition was machine computed by a method similar to that of Drellishak, Knopp, and Cambel [17] including first order Debye corrections. The partition functions as functions of the cutoff energy were analytically smoothed and made to assume the asymptotic hydrogenlike form at the ionization energy limit (9). The number density of triply ionized argon atoms was assumed negligible thus limiting the calculations to temperatures below about 20 000 °K. The computed composition table including upper level populations pertinent to the present experiments is presented as table 2. Griem’s treatment [18] of high density corrections to plasma composition calculations suggests that table 2 should be accurate to approximately 1 percent.

Table 2.

Argon plasma composition at 1.00 atm pressure*

T Z0 Z1 Z2 U0 U1 U2 Ne N0 N1 N2
5000 1.0000 5.3246 7.904 127106 222812 329954 1.322E 12 1.468E 18 1.322E 12 3.642E-07
5500 1.0000 5.3752 8.034 127101 222803 329940 7.174E 12 1.335E 18 7.174E 12 1.441E-04
6000 1.0000 5.4188 8.158 127093 222787 329916 2.944E 13 1.223E 18 2.944E 13 2.135E-02
6500 1.0000 5.4567 8.278 127081 222762 329879 9.746E 13 1.129E 18 9.746E 13 1.485E 00
7000 1.0000 5.4901 8.393 127063 222726 329825 2.724E 14 1.048E 18 2.724E 14 5.702E 01
7500 1.0000 5.5196 8.506 127039 222678 329753 6.648E 14 9.775E 17 6.648E 14 1.361E 03
8000 1.0000 5.5459 8.615 127009 222617 329662 1.453E 15 9.147E 17 1.453E 15 2.205E 04
8500 1.0000 5.5695 8.722 126971 222542 329549 2.898E 15 8.579E 17 2.898E 15 2.599E 05
9000 1.0001 5.5908 8.827 126926 222453 329415 5.352E 15 8.050E 17 5.352E 15 2.347E 06
9500 1.0001 5.6101 8.929 126875 222350 329261 9.254E 15 7.543E 17 9.254E 15 1.693E 07
10000 1.0003 5.6276 9.029 126818 222235 329089 1.51 IE 16 7.041E 17 1.51IE 16 1.009E 08
10500 1.0005 5.6437 9.126 126755 222109 328900 2.342E 16 6.527E 17 2.342E 16 5.104E 08
11000 1.0009 5.6584 9.221 126688 221975 328699 3.466E 16 5.987E 17 3.466E 16 2.239E 09
11500 1.0015 5.6720 9.314 126618 221836 328491 4.910E 16 5.412E 17 4.910E 16 8.668E 09
12000 1.0025 5.6845 9.405 126549 221698 328283 6.672E 16 4.798E 17 6.672E 16 3.008E 10
12500 1.0039 5.6961 9.493 126482 221564 328082 8.705E 16 4.153E 17 8.705E 16 9.473E 10
13000 1.0061 5.7069 9.579 126421 221441 327898 1.09 E 17 3.492E 17 1.091E 17 2.735E 11
13500 1.0093 5.7170 9.663 126367 221334 327738 1.315E 17 2.843E 17 1.315E 17 7.307E 11
14000 1.0140 5.7264 9.745 126325 221249 327610 1.525E 17 2.235E 17 1.525E 17 1.820E 12
14500 1.0208 5.7353 9.825 126294 221188 327517 1.705E 17 1.698E 17 1.705E 17 4.255E 12
15500 1.0441 5.7515 9.978 126268 221135 327439 1.942E 17 9.030E 16 1.942E 17 1.97 IE 13
16000 1.0630 5.7590 10.052 126269 221138 327443 1.998E 17 6.426E 16 1.997E 17 3.949E 13
16500 1.0890 5.7662 10.124 126277 221154 327467 2.022E 17 4.557E 16 2.020E 17 7.586E 13
17000 1.1241 5.7731 10.195 126289 221178 327504 2.02 IE 17 3.248E 16 2.018E 17 1.403E 14
17500 1.1706 5.7799 10.263 126304 221208 327549 2.004E 17 2.344E 16 1.999E 17 2.506E 14
18000 1.2315 5.7865 10.330 126321 221241 327598 1.976E 17 1.720E 16 1.967E 17 4.336E 14
18500 1.3099 5.7932 10.395 126337 221275 327648 1.943E 17 1.288E 16 1.928E 17 7.283E 14
19000 1.4093 5.7999 10.459 126354 221307 327697 1.907E 17 9.856E 15 1.883E 17 1.189E 15
19500 1.5334 5.8068 10.522 126369 221338 327744 1.870E 17 7.704E 15 1.833E 17 1.890E 15
T N e 4044 AI 4159 AI 4259 AI 4272 AI 4300 AI 4348 AII 4806 AII
5000 1.322E 12 1.153E 04 1.669E 04 2.054E 03 1.01 IE 04 1.760E 04 4.465E-08 6.290E-08
5500 7.174E 12 2.324E 05 3.252E 05 4.184E 04 1.968E 05 3.414E 05 1.467E-05 1.952E-05
6000 2.944E 13 2.818E 06 3.835E 06 5.118E 05 2.319E 06 4.009E 06 1.840E-03 2.333E-03
6500 9.746E 13 2.313E 07 3.073E 07 4.23IE 06 1.858E 07 3.202E 07 1.099E-01 1.339E-01
7000 2.724E 14 1.397E 08 1.819E 08 2.572E 07 1.099E 08 1.890E 08 3.667E 00 4.314E 00
7500 6.648E 14 6.604E 08 8.450E 08 1.223E 08 5.102E 08 8.755E 08 7.675E 01 8.764E 01
8000 1.453E 15 2.557E 09 3.222E 09 4.758E 08 1.945E 09 3.33 IE 09 1.100E 03 1.223E 03
8500 2.898E 15 8.398E 09 1.044E 10 1.569E 09 6.298E 09 1.077E 10 1.153E 04 1.252E 04
9000 5.352E 15 2.401E 10 2.948E 10 4.503E 09 1.778E 10 3.037E 10 9.30 IE 04 9.90IE 04
9500 9.254E 15 6.094E 10 7.404E 10 1.147E 10 4.464E 10 7.614E 10 6.016E 05 6.288E 05
10000 1.51 IE 16 1.395E 11 1.678E 11 2.633E 10 1.012E 11 1.723E 11 3.220E 06 3.310E 06
10500 2.342E 16 2.910E 11 3.471E11 5.509E 10 2.092E 11 3.560E 11 1.462E 07 1.480E 07
11000 3.466E 16 5.581E 11 6.603E 11 1.059E 11 3.979E 11 6.764E 11 5.745E 07 5.738E 07
11500 4.910E 16 9.889E 11 1.161E 12 1.881E 11 6.997E 11 1.189E 12 1.985E 08 1.958E 08
12000 6.672E 16 1.624E 12 1.895E 12 3.096E 11 1.141E 12 1.937E 12 6.108E 08 5.957E 08
12500 8.705E 16 2.478E 12 2.873E 12 4.731E 11 1.730E 12 2.934E 12 1.690E 09 1.631E 09
13000 1.091E 17 3.513E 12 4.049E 12 6.719E 11 2.438E 12 4.133E 12 4.242E 09 4.055E 09
13500 1.315E 17 4.631E 12 5.311E 12 8.874E 11 3.198E 12 5.417E 12 9.722E 09 9.209E 09
14000 1.525E 17 5.689E 12 6.492E 12 1.092E 12 3.908E 12 6.616E 12 2.048E 10 1.924E 10
14500 1.705E 17 6.534E 12 7.423E 12 1.256E 12 4.468E 12 7.560E 12 3.991E 10 3.720E 10
15000 1.846E 17 7.063E 12 7.990E 12 1.359E 12 4.809E 12 8.133E 12 7.254E 10 6.713E 10
15500 1.942E 17 7.252E 12 8.171E 12 1.397E 12 4.918E 12 8.312E 12 1.240E 11 1.140E 11
16000 1.998E 17 7.147E 12 8.023E 12 1.379E 12 4.828E 12 8.157E 12 2.010E 11 1.836E 11
16500 2.022E 17 6.832E 12 7.642E 12 1.319E 12 4.599E 12 7.767E 12 3.116E 11 2.829E 11
17000 2.021E 17 6.394E 12 7.128E 12 1.236E 12 4.289E 12 7.241E 12 4.653E 11 4.201E 11
17500 2.004E 17 5.899E 12 6.557E 12 1.141E 12 3.945E 12 6.657E 12 6.732E 11 6.046E 11
18000 1.976E 17 5.394E 12 5.978E 12 1.045E 12 3.596E 12 6.067E 12 9.479E 11 8.470E 11
18500 1.943E 17 4.905E 12 5.421E 12 9.508E 11 3.261E 12 5.499E 12 1.303E 12 1.159E 12
19000 1.907E 17 4.445E 12 4.899E 12 8.624E 11 2.947E 12 4.968E 12 1.754E 12 1.553E 12
19500 1.870E 17 4.019E 12 4.419E 12 7.804E 11 2.658E 12 4.480E 12 2.313E 12 2.039E 12
T N e 6753 AI 6871 AI 6965 AI 7030 AI 9195 AI 9292 AI
5000 1.322E 12 1.016E 04 6.565E 03 1.626E 05 8.131E 03 1.891E 04 6.510E 03
5500 7.174E 12 2.072E 05 1.330E 05 2.460E 06 1.692E 05 3.478E 05 1.194E 05
6000 2.944E 13 2.537E 06 1.619E 06 2.348E 07 2.106E 06 3.908E 06 1.338E 06
6500 9.746E 13 2.099E 07 1.333E 07 1.574E 08 1.768E 07 3.007E 07 I.028E 07
7000 2.724E 14 1.277E 08 8.074E 07 7.994E 08 1.088E 08 1.719E 08 5.863E 07
7500 6.648E 14 6.072E 08 3.826E 08 3.251E 09 5.232E 08 7.745E 08 2.638E 08
8000 1.453E 15 2.364E 09 1.485E 09 1.104E 10 2.056E 09 2.876E 09 9.785E 08
8500 2.898E 15 7.798E 09 4.886E 09 3.228E 10 6.838E 09 9.103E 09 3.093E 09
9000 5.352E 15 2.238E 10 1.399E 10 8.323E 10 1.977E 10 2.518E 10 8.546E 09
9500 9.254E 15 5.703E 10 3.557E 10 1.926E 11 5.071E 10 6.207E 10 2.105E 10
10000 1.511E 16 1.310E 11 8.153E 10 4.058E 11 1.171E 11 1.384E 11 4.687E 10
10500 2.342E 16 2.741E 11 1.703E 11 7.853E 11 2.464E 11 2.819E 11 9.542E 10
11000 3.466E 16 5.270E 11 3.270E 11 1.407E 12 4.762E 11 5.289E 11 1.789E 11
11500 4.910E 16 9.362E 11 5.800E 11 2.341E 12 8.496E 11 9.186E 11 3.106E 11
12000 6.672E 16 1.541E 12 9.536E 11 3.632E 12 1.404E 12 1.482E 12 5.006E 11
12500 8.705E 16 2.356E 12 1.456E 12 5.256E 12 2.155E 12 2.223E 12 7.505E 11
13000 1.091E 17 3.346E 12 2.066E 12 7.098E 12 3.071E 12 3.102E 12 1.047E 12
13500 1.315E 17 4.420E 12 2.725E 12 8.948E 12 4.069E 12 4.032E 12 1.360E 12
14000 1.525E 17 5.438E 12 3.350E 12 1.054E 13 5.022E 12 4.888E 12 1.648E 12
14500 1.705E 17 6.256E 12 3.850E 12 1.165E 13 5.793E 12 5.545E 12 1.869E 12
15000 1.846E 17 6.773E 12 4.165E 12 1.214E 13 6.287E 12 5.925E 12 1.997E 12
15500 1.942E 17 6.963E 12 4.278E 12 1.205E 13 6.479E 12 6.018E 12 2.027E 12
16000 1.998E 17 6.871E 12 4.219E 12 1.150E 13 6.408E 12 5.871E 12 1.977E 12
16500 2.022E 17 6.576E 12 4.035E 12 1.067E 13 6.146E 12 5.559E 12 1.872E 12
17000 2.021E 17 6.161E 12 3.778E 12 9.710E 12 5.770E 12 5.156E 12 1.735E 12
17500 2.004E 17 5.691E 12 3.487E 12 8.724E 12 5.339E 12 4.717E 12 1.587E 12
18000 1.976E 17 5.209E 12 3.190E 12 7.780E 12 4.895E 12 4.279E 12 1.439E 12
18500 1.943E 17 4.741E 12 2.902E 12 6.909E 12 4.463E 12 3.862E 12 1.299E 12
19000 1.907E 17 4.300E 12 2.631E 12 6.122E 12 4.055E 12 3.475E 12 1.168E 12
19500 1.870E 17 3.891E 12 2.379E 12 5.419E 12 3.675E 12 3.121E 12 1.049E 12
*

Z0, Z1, and Z2 are internal partition functions for neutral, singly ionized, and doubly ionized argon atoms respectively. U0, U1, and U2 are effective ionization energies [cm−1]. N,., N0, N1, and N2 are number densities of electrons, neutral, singly ionized, and doubly ionized argon atoms [cm−3]. Columns headed by a wavelength contain number densities in the upper state of the line: e.g., under 4300 AI is tabulated N0gu exp(-Eu/lkT)Z0 with gu = 5, EU, = 116999 cm-1.

Finally the electron density and Hβ line intensity obtained from the Hβ line shape fitting are used iteratively in conjunction with this table to determine the total hydrogen content and the number density of excited argon atoms at the radial points considered. The argon transition probabilities are then found by division of the total line intensities (in photons per cubic centimeter per second) by these number densities at corresponding radii. The individual values of the transition probabilities obtained in this manner are presented in figures 11, 12, and 13. The averages of these experimental transition probabilities are given in table 3.

Figure 11. AI 4300 Å transition probability values.

Figure 11.

Ave. = 4.11×105 sec−1. Std. dev. = 0.29× 105 sec−1.

Figure 12. AI 6965 Å transition probability values.

Figure 12.

Ave. = 7.10× 106 sec−1. Std. dev. = 0.55× 106 sec−1.

Figure 13. AII 4806 Å transition probability values.

Figure 13.

Ave. = 1.31×108 sec−1. Std. dev. = 0.2l× 108 sec.−1.

Table 3.

Argon transition probabilities

Wavelength Transition A × 10−6 [sec−1]
This expt. Drawin Gericke Olsen Richter Pery-Thorne Garstang
4044 1 1s4 ‒ 3p3 0.45 ± 13% 0.37 0.35
4159 I 1s5 ‒ 3p6 1.60 ± 13% 1.7 1.2 0.66
4259 I 1s2 ‒ 3p1 4.4 ± 14% 4.0 3.3 2.5
4272 I 1s2 ‒ 3p7 0.94 ± 14% 0.76 0.69 0.37
4300 I 1s4 ‒ 3p8 0.411 ± 11% .36 .32
4348 II 4s4P ‒ 4p4 240 ± 27% 115 128
4806 II 4s4P ‒ 4p4 131 ±23% 79 79
6753 I 2p10 ‒ 4d3 2.9 ± 12%
6871 I 2p10 ‒ 4d5 4.0 ± 13%
6965 I 1s5 ‒ 2p2 7.10 ± 11% 5.3 8.7
7030 1 2p10 ‒ 3s5 4.0 ± 12%
9195 I 2p10 ‒ 2s3 2.2 ± 12%
9292 I 2p10‒ 2s3 4.5 ± 12%

The transition probabilities of the lines other than 6965, 4300, and 4806 were determined relative to one or another of these three reference lines. The lines lying in the red and infrared were measured using the digital apparatus described above with full Abel inversion but with wider slits and with an abbreviated wavelength scan. The plasma composition was obtained from measurements of the AI 6965 Å intensity using a transition probability of 7.10 × 106 sec−1. The lines in the blue were measured using an analog computer [19] for the direct recording of the Abel inverted spectra. In this way it was felt that the separation of overlapping lines (see fig. 1) could be better accomplished—although somewhat subjectively. The line intensities were determined by planimeter integration and the plasma composition was derived from the measured AI 4300 Å intensity (using A = 4.11 × 105 sec−1) for the neutral lines and from the AII 4806 Å intensity (using A = 1.3l × 108 sec−1) for the AII 4348 Å line. Because of the less satisfactory estimates of the line wing corrections, the limited number of experiments, and the uncertainty in the reference transition probabilities the A values for these lines are slightly less accurate than those for the 4300, 6965, and 4806 lines.

3.4. Hydrogen-Argon Ratio

The ratio of the total hydrogen content to the total argon content as determined from the Hβ shape and intensity measurements alone is shown in figure 14 as a function of radial position for some 60 A experiments. This ratio is defined as

k=(2NH2+NH+NH+)/(NA+NA++NA+++)

where NH2, NH, etc., are number densities of the species H2, H, etc. All of the experiments in figure 14 utilized a premixed tank of the hydrogen-argon mixture with a value for this ratio of about 0.02 as determined by a mass spectrometric analysis. This figure illustrates the ““demixing” effect [9] which precludes the use of cold gas composition data in determining the plasma composition in arcs containing gas mixtures.

Figure 14.

Figure 14.

The hydrogen/argon atomic ratio, k, as a function of radius for some 60 ampere experiments.

4. Discussion of Errors

The recent appearance of a detailed and self-consistent theoretical treatment [9] of the problems of laboratory plasma sources and of spectroscopic plasma diagnostics together with the relatively large data sample sizes that can be accumulated with automatic recording and computing techniques makes possible a much more thorough error analysis than has heretofore been attempted. A discussion of several sources of error follows. In general it is found that the expected experimental and theoretical errors are of roughly comparable magnitudes.

4.1. Electronic

The maximum imprecision of the recorded intensities due to instrumental uncertainties was determined to be of the order of 0.15 percent. This figure results from the treatment as independent errors of the maximum effects of instrument nonlinearities and zero drift over a period of 1 hr with the combined effects of ambient temperature variations of plus or minus 5 °C and ± 10 percent line voltage fluctuations, and includes the contributions from the photomultiplier high-voltage power supply, the current amplifier, the voltage-to-frequency converter and the electronic counter.

An additional variation has been observed in the photomultiplier dark current on the higher gain range settings of the amplifier. This effect became noticeable after the dark current had been suppressed and appeared to consist of a long-term drift of the dark current of as much as 1 percent of full scale accompanied by short-term random noise of a similar magnitude.

The effects of photomultiplier fatigue on the photocurrent measurements were made negligible by restricting anode currents in the photomultiplier to less than 10−7 A, a value which previous investigations had shown to be below the threshold of fatigue effects for these tubes.

A certain amount of delay in the response of the photomultipliers to step inputs was observed. A rise time of about 0.2 sec was measured for the phototubes with S—20 response, while the delay was un-measureable for the S—4 phototubes, implying some dependence on photocathode material. To ensure sufficient time for any effects of photomultiplier delay, mechanical relaxation or transient vibrations to decay, the recording of the photocurrent was postponed until 0.25 seconds after the arc chamber had completed its shift to a new position.

4.2. Calibration

The absolute calibration of the source intensities with a tungsten strip lamp is subject to a maximum uncertainty of about ± 5 percent. The brightness temperature calibration of the strip lamp at NBS is qualified by a certificated uncertainty of ± 7 °C relative to the IPTS which would produce uncertainties of about ± 3 percent in the transition probabilities of both neutral and ionic lines. For the calculation of the strip lamp emission at wavelengths other than the calibration wavelength (6530 Å) the tungsten emissivities given by DeVos [20] were used. These are estimated to be accurate to within ± 2 percent. The maximum uncertainty due to this cause would therefore presumably be ± 2 percent in the blue and infrared spectrum and would decrease to zero at the calibration wavelength.

The errors in intensity due to uncertainties in determination of the correct strip lamp current are around ±0.07 percent, almost two orders of magnitude below the errors discussed above and therefore negligible. The combined expected uncertainties are therefore ±5 percent for blue and infrared lines decreasing to ±3 percent for lines in the red.

4.3. Arc Source

The argon used in these experiments was technical grade argon with typically a purity of 99.996 percent containing mainly nitrogen and oxygen as contaminants. The gas flow system in the arc chamber is designed to prevent atmospheric and electrode contaminants from entering the observation chamber and indeed no impurities were observed spectroscopically during the experiments. From this observation the impurity upper limit and corresponding transition probability error of the order of 1 percent can be set based upon a minimum detectable signal and estimated transition probabilities for lines of the likely impurities, C, N, and 0.

The arc current regulator maintains the arc current constant to within 0.05 percent for periods of 1/4 or 1/2 hr. Effects of a long-term drift presumably due to ohmic heating of the oil-cooled regulator shunt were minimized by monitoring the arc current at intervals with a potentiometer and precision shunt and making small manual corrections. Oscilloscopic observation of the arc current reveals a 0.3 percent 360 cycle ripple when the rotary converter power supply is used. Assuming the totally unrealistic worst possible case—that the averaging over the 0.1 sec counting time results in a measurement of the electron density at one current extremum and of the line intensity at the other—then the ensuing error in the transition probabilities would be of the order of 0.5 percent and 1 percent for the AI and AII lines respectively.

The arc positioning mechanism is capable of locating the arc chamber to within 0.002 cm, with a repeatability an order of magnitude better. Since these positioning errors are attributed to the lead screw and are therefore noncumulative, they will appear on the recorded profile of the traverse as noise amounting at most to about 0.4 percent rms of the maximum signal.

The assumed total are pressure of 1 atm is clearly an approximation. No record was kept of the prevailing atmospheric pressure during the experiments so that day-to-day pressure fluctuations of 2 or 3 percent must be expected. The over-pressure of the argon in the arc required to maintain the steady gas flow was 0.0003 atm. The arc column over-pressures due to magnetic self-compression and due to the momentum transport accompanying the heat transport can be estimated [9] for the 90 A arc as 0.0003 atm and 0.02 atm respectively. Thus the actual pressure at all points in the arc was at all times probably within 5 percent of the 1 atm assumed for the calculations. By repeating the plasma composition calculations (table 2) at other pressures the effect of this pressure uncertainty upon the transition probabilities can be evaluated. The result is that a ±5 percent error in pressure produces a ∓ 1 percent error in the neutral line transition probabilities and a ±8 percent error in the ionic line values.

4.4. Optical

Any nonuniformity of the arc in the axial direction within the observation chamber will result in transition probability errors due to the finite height of the spectrometer slit which collects light from a region 0.05 cm long in the axial direction and because of the resulting signal averaging which will be different for line widths, neutral line intensities, and ion line intensities. Estimates of the maximum errors from this source based upon measurements taken during a crude scan along the arc axis are 0.5 percent and 4 percent for neutral and ionic line transition probabilities respectively. Similar errors arise in the steep gradient regions of the arc because of imaging errors of the optical system and the finite width of the entrance slit. The combined lateral image smearing was determined to be less than 0.005 cm for the 15μ slit by moving the edge of a tungsten strip filament lamp across the optic axis at the arc position and observing the “halfwidth” of the signal step. The corresponding maximum transition probability errors in this case are also 0.5 percent and 4 percent respectively at the edges of the arc. In all cases the experimental values should be too high. Turbulence, if present in the arc, would lead to similar errors. However, estimates of the Reynolds number for the conditions of these experiments lie well within the laminar flow region suggesting that this should not be a problem. Optical refractivity gradients in the arc are expected to cause a negligible distortion of the arc intensity profile even in the vicinity of strong lines [9]. This expectation was partially confirmed experimentally by the failure to detect a significant displacement of the apparent position of the edge of a tungsten strip lamp filament imaged into the arc plasma at any observing wavelength near the AI 6965 Å line.

Scattering of light by the optical elements and are chamber windows would cause an increase in the apparent transition probabilities at the higher radii, i.e., at the edges of the luminous are column. Since a slight variation of this type was indeed observed, several experiments were performed with no window in the arc chamber. These failed to show a significant difference at the arc edges from those in which the window was included in the optical path. Direct rough measurements of the light scattered by the optical elements showed this amount to be less than 0.3 percent of the maximum source intensity, which could not possibly account for the observed radial variation of the A-values.

The shot noise arising from statistical fluctuation in the arrival of photons at the photomultiplier can be estimated from the source intensity and the geometry of the optical train. It is estimated to be always less than 0.5 percent for the strip lamp calibration and less than 0.1 percent for the arc, except at the extreme edges.

For some experiments the limiting aperture of the optical system was reduced to one-half its original size. Any observed difference in the results of these experiments would have pointed out errors and misalinements of the optical system. No such differences were observed, indicating that the optical system was properly alined and that the original aperture was indeed limiting.

The degree of self-absorption can be estimated by calculating the optical depth τ=20Rκdr where

κ=ϵ/B(T)

and

B(T)=2hc2λ5(ehc/λkT1)1

k’ is the effective absorption coefficient (cm−1), and ϵ is the observed radially resolved emission coefficient per steradian (erg sec−1 cm−3 sr−1 cm−1). The results of such calculations at the centers of the three lines at 4300, 6965, and 4806 Å are respectively 0.002, 0.11, and 0.002 for the optical depths, τ, in the worst cases encountered. Since the Abel inversion is most unstable near the center due to the infinite kernel at that point it is to be expected that the consequences of errors in the side-on intensity measurements due to self-absorption will normally be most severe in the radially inverted values near the center of the arc. This is borne out by exact analytic calculations of simple models and by the approximate Freeman and Katz [10] treatment of more realistic models. These calculations indicate that for small degrees of self-absorption and for bell-shaped profiles the relative error in the radially resolved emission coefficient is of the order of κ0R at the arc center where K0 is the effective absorption coefficient at the center and R is, as before, the nominal arc radius. Thus only in the case of the AI 6965 Å line will self-absorption play a role leading to transition probabilities that are too low by about 5 percent (κ0R averaged over the line shape) at the arc center and increasing to the correct value at the edge. To some extent this conclusion appears to be supported by the data of figures 11 and 12 which show for the 6965 Å line a more pronounced depression of the transition probabilities at high electron densities near the arc center.

4.5. Analytical and Theoretical

In general, the accuracy of an Abel inversion based on curve fitting techniques is dependent upon the form of the intensity profile of the arc traverse and the fitting function, the number of polynomials used in the fitting function, the number of increments examined during each arc traverse, and the noise present on the intensity profile. To assess the effects of these variables on the accuracy of the inversion, analytical test functions were constructed with varying amounts of superimposed noise drawn from a table of random normal deviates. These test functions, which are of the same general shape as the observed profile of the arc traverse, were then inverted by the machine program used in processing the experimental results. As expected, for data with a relatively high noise level a small number of polynomials in the fitting function produces the best inversion in terms of accuracy of fit and minimum noise amplification. Conversely, no significant improvement in accuracy results from using large numbers of increments and terms unless the signal/noise ratio of the data is quite high. The accuracy of the inversion is, however, relatively insensitive to variations in number of increments for noise levels greater than 0.3 percent due to the smoothing inherent in the curve fitting process and in this range the relative noise level of the inverted profile is almost identical to that on the original recorded intensity profile.

The results of tests on analytical functions were borne out by further tests of the inversion on actual experimental profiles. The number of data points of representative many-point arc traverses was halved and quartered by systematically discarding alternate data points, and the resulting “thinned” traverses inverted and compared to the originals. These tests also showed that, at least for the data encountered here, no further accuracy could be attained by taking more than 20 or 30 measurements per arc traverse. Similarly, the use of more than 8 or 10 terms in the polynomial expansion was again not warranted and, in fact, increased the noise level in the results.

Numerical tests of the dispersion shape fitting program carried out by superimposing noise upon calculated dispersion shapes reveals that the relative rms noise on the computed line intensity and halfwidth is roughly equal to the relative noise in the input intensity data at the half maximum intensity level. Thus, little smoothing of the noise is accomplished in this step. This is due mainly to the influence of the noise upon the background or continuum level determination by the program. In these experiments this determination was dependent upon a comparatively small effective number of points due to the wavelength point distribution employed.

The use of the area of the fitted dispersion shape as the spectral line intensity obviates the necessity for correcting measured line intensities for that portion of the line lying below and beyond the end points of the wavelength scan. This is a significant correction amounting to 13 percent for scans of only ten half-widths and may account for part of the difference between the transition probabilities observed here and the lower values of other workers. Since the experimental line shapes even after correction for apparatus functions are not expected to be quite dispersion shapes [9] it was necessary to ascertain the effect of departures from the dispersion shape upon the linewidth, shift, and intensity values as measured in these experiments. For this purpose the dispersion shape fitting program was applied to a theoretical complete asymmetric line shape [21] which appears to be reasonably representative of the experimental line shapes encountered here. The computed intensities and halfwidths were consistently low by 3 percent and 2 percent respectively. The line shifts were consistently overestimated by a magnitude approximately equal to the error in the ½-halfwidth. No attempt was made to calibrate the dispersion shape fitting program for these theoretical line shapes because of the unavailability of sufficiently extensive tables of the necessary line shapes. Consequently, systematic errors can be expected in the results amounting to perhaps 5 percent and probably always in the direction indicated by this example.

At the heart of these measurements is the determination of the electron density by the Hβ line shape measurement. Unfortunately a significant uncertainty in the results is associated with this step. For example, Griem [9] estimates that the electron densities obtained from Hβ line shapes are probably reliable only to about 5 percent based upon an analysis of the theoretical approximations. In addition, as indicated in figure 4, some error is involved in the fitting of a theoretical line shape to the experimental data. Typically the rms deviation of the experimental points from the fitted curve is 2 or 3 percent of the maximum Hβ intensity. (This is somewhat better than the dispersion shape fitting to the argon lines which typically has an rms deviation of 3 to 5 percent. However, in part this greater error is explained by the influence of the apparatus or slit function which is not taken into account in the fitting and by the approximation of the true theoretical shapes by the dispersion shape.) The subtraction of the pure argon spectrum from the argon + hydrogen spectrum removes the major part of any uncertainties in the Hβ shape measurement due to irregularities in the argon continuum underlying the hydrogen line. Any errors in this step due to small changes in the radial temperature profile caused by the addition of the trace of hydrogen are expected to be negligible but presumably are included in this 2 or 3 percent deviation. As a partial check of these Hβ measurements in two of the 60 A experiments Hβ line shapes were also recorded. From the electron density, temperature, and hydrogen to argon ratio as determined from the Hβ measurements the theoretical intensity and shape of the Hα lines were computed using the Griem, Kolb, and Shen tabulations. Figure 15 shows a comparison of an experimental Hα line shape (after the Abel inversion and subtraction of the pure argon spectrum) with the theoretical shape based upon the Hβ measurements at the same radial point. The agreement is seen to be satisfactory in the wings and at the center but the halfwidth of the theoretical shape is 10 percent or so smaller than the experimental one. This difference appears to be in accord both in magnitude and direction with the correction to the theoretical Hα shapes which Griem et al., [14] estimate would accrue by taking into account the improved ion field strength distribution functions of Mozer and Baranger. Thus, in conclusion, it is reasonable to assume that the electron densities obtained in these experiments from the Hβ line shapes should not be in error by much more than about 5 percent. This results in 8 and 20 percent uncertainties respectively in the AI and AII transition probabilities.

Figure 15.

Figure 15

Experimental intensity points in the neighborhood of Hα 6563 Å after Abel inversion (on axis of 60 ampere arc in argon with ∼ 1% H2) with theoretical Hα line shape computed from parameters obtained by Hβ measurements: Ne=7.35 ×16 cm−3, k = 0.0197.

Griem [22] has discussed in detail the validity of the local thermodynamic equilibrium (L.T.E.) assumption in laboratory plasmas. Using his criteria one finds that for homogeneous plasmas of the dimensions of the arcs of these experiments complete L.T.E. would be probable down to the lowest electron densities actually utilized in the measurements −2 × 1016 for neutral species and 5 × 1016 for ionic species. Again following Griem’s treatment one finds that the greatest average distance traveled by any species in the arc between equilibrating collisions is that of the ground state neutrals of the order of 10−2 cm at the axis. Thus, the measured electron density and line intensities at a particular point in the arc are not to be interpreted as corresponding exactly to L.T.E. conditions at the local electron temperature at that point but rather as appropriate to some kind of averaging of near-equilibrium distributions which exist over a distance of the order of 10−2 cm. The use of this distance, then, permits some estimate of the effects of the temperature and composition gradients present in the arc upon the accuracy of the transition probability determinations. Clearly an over-estimate of the errors is obtained by coupling line intensity measurements at one point with equilibrium calculations based upon electron density measurements 10−2 cm away. Such a procedure result3 in error estimates of 1 percent for the neutral lines and 2 percent for the ionic lines at the center of the 90 A arc. Away from the center this equilibrating collision distance is not a proper measure of the L.T.E. smearing because of the additional equilibrating influences of the diffusion of ions and excited atoms from the hot core and the absorption of resonance radiation from the core. The fact that the measured transition probabilities show no strong dependence upon the electron density, however, suggests that if departures from L.T.E. are not serious at the arc center they are probably also not serious at least out to 0.2 cm where the lowest electron density measurements were taken.

5. Discussion of Results

The estimated transition probability uncertainties resulting from this error analysis assuming the errors are independent are included in table 3 together with transition probability values obtained by other investigators. Most of the errors which have been discussed are systematic. However, a few—the electronic noise, the numerical curve fitting errors, the day-today pressure variation, and the dark current drift errors—are not and will tend to be reduced in magnitude by the averaging over the many experiments or radii. In arriving at the uncertainty estimates in table 3 due allowance for this kind of error was taken, where appropriate, by division by the square root of the sample number. A similar calculation applied to the neutral line width and shift measurements gives an estimated 6 percent uncertainty.

The three dominating errors in the average transition probability values determined here are the absolute intensity calibration errors, the systematic errors in the argon line shape fitting due to apparatus functions and asymmetry, and the estimated uncertainty in the hydrogen line broadening theory. It is now possible to reduce the effect of calibration uncertainties from the 3 to 5 percent estimated in these experiments to about 1 to 2 percent, by means of new NBS radio-metric calibration services which have become available on a limited basis [24] since these experiments were undertaken. Also, with some effort, the argon line shape fitting can be improved by the calculation and use of more extensive theoretical line shape tables including asymmetry and possibly with apparatus and Doppler broadening properly folded in. Thus the experimental errors can probably be reduced by a factor of two without excessive effort. However, without a concomitant improvement in the accuracy of the electron density determination these experimental improvements would only marginally reduce the estimated overall errors. The uncertainty in this step is the major contribution to the error estimates in table 3. Griem’s estimate of the accuracy of the hydrogen line shape calculation is not significantly changed by consideration of the small amount of relatively contradictory experimental evidence [9]. Further experimental or theoretical studies should permit a better assessment of the accuracy of this extremely useful plasma diagnostic technique.

The origin of the apparent decrease of the transition probabilities with increasing electron density (see e.g., fig. 11) is unknown. Of the error sources described above, the only pertinent ones estimated to be of sufficient magnitude to encompass this effect are hydrogen line broadening theory errors, line shape fitting errors, and possibly departures from L.T.E. This deviation from a constant transition probability agrees qualitatively with the discrepancies observed by Wiese et al. [25] in pure hydrogen arcs.

The scatter of the transition probability values (figs. 4 to 13) is in agreement with the noise level estimates described above. These were mainly electronic and amounted to 1 or 2 percent of the maximum signals. When expressed in terms of the half-intensity of a line this relative noise level is higher by a factor of two or more, and, consequently, since neither the Abel inversion nor the dispersion line fitting seems to modify the noise level, the line intensities should exhibit a scatter of several percent. When combined with a similar noise in the electron density values a resultant scatter of the transition probability values of the order of 5 to 10 percent is to be expected.

The theoretical transition probabilities of Garstang [23], the “hook” method values of Pery-Thorne and Chamberlain [1], and the arc measurements of Drawin [4] appear to agree generally with the present values in the sense that the error ranges assigned by the investigators overlap the present ones. (The theoretical values are good to perhaps a factor of two, Pery-Thorne and Chamberlain estimate an accuracy of 20 to 30 percent for their values, and Drawin assigns error limits ranging from10 percent for AI 4044 A to 20 percent for AI 4300 Å.) Drawin’s measurements were carried out in an arc containing a hydrogen-argon mixture. However, since his diagnostics were based upon hydrogen line intensity measurements and the use of the cold gas composition there is a possibility of a systematic error due to demixing.

Gericke’s argon transition probabilities [3] are based upon an argon arc temperature profile derived from measurements of the AII 4348 Å line intensity using a transition probability value of 68 × 106 sec−1. The value obtained in the present work for this transition probability is 240 × 106 sec−1. If this is correct then Gericke’s transition probability values should be increased by about 35 percent3 and would agree well with the present values. These same comments apply to Richter’s value for the AI 4044 A line (27) which was evidently obtained similarly. The corresponding adjustments to Gericke’s electron density values result, in the case of the AI 4300 Å line, in values (in Å) for the 12-halfwidth and shift both approximated by 0.12 × 10−16[Ne] where Ne is the number of electrons per cm3. This compares reasonably well with the present values (table 1) of 0.10 × 10−16[Ne] Thus the measurements reported here are evidently well in accord with Gericke’s on a relative basis but the absolute results differ through the use of the Hβ line shape for the arc diagnostics rather than the AII 4348 Å transition probability used by Gericke.

In the case of Olsen’s results an estimate of the degree of self-absorption at the center of the AII 4806 Å line4 under his arc conditions leads to values for the optical depth, τ, of 0.7 or 0.3 depending upon whether the line halfwidth is estimated from Griem’s theoretical calculations [9] or is extrapolated from the experimental data of figure 9. In either case the magnitude is sufficient to cause a serious error in the radially resolved emission coefficient and to raise doubts about whether Olsen’s observed apparent off-axis maximum was not in fact a consequence of this absorption rather than a manifestation of the Larenz and Bartels [28] “normal” temperature effect. In this event Olsen’s temperature determinations and transition probabilities are open to radical reinter-pretation.

Table 1 compares the measured values of the line widths and shifts (averaged assuming they are proportional to the electron density) with theoretical values computed from Griem’s tables [9] for a temperature of 12 000 °K. Fortunately the theoretical values of the reduced widths and shifts are not strongly temperature dependent so that the difference between 12 000° and whatever effective temperature is introduced by the averaging of the experimental values will cause a difference of only a few percent in the tabular entries. For the neutral argon lines the agreement of theory and experiment is roughly within the expected accuracy of 8 percent for the experiments and 20 percent for the theory. The ion line results, however, are in very poor agreement with theory. For the line shift this is understandable since the theoretical Stark shift for the line does not include the plasma polarization blue shift [9] which rough calculations indicate will be larger than the Stark shift. For the width of the AII 4806 Å line errors due to both Doppler broadening and the slit width correction procedure are important but do not appear to be sufficient to resolve the discrepancy between theory and experiment. The consequences of neglecting the Doppler broadening were estimated by folding the Doppler line shape (Gaussian with 12-halfwidth of approximately 0.03 Å) into the apparatus function to give a broadened effective apparatus function. The use of this modified apparatus function (which significantly affects only the narrow ionic line) reduces the widths of figure 9 by approximately 0.005 Å and decreases the proportionality constant in table 1 by about 5 percent. The error in this proportionality constant stemming from the application of the slit width correction procedure to the AII 4806 Å line where the line and apparatus function widths are comparable (line width: 0.08 Å to 0.15 Å: apparatus width: 0.1 Å) is estimated at 10 or 20 percent. This figure is based upon the results of the 150 μ slit width experiment in which the apparatus function was wider than the AI 4300 Å line at all radii. In this case application of the slit width correction procedure to the computer fitted line widths resulted in an average value for wNe×1016 of 0.089 compared to the average 0.100 for all the narrow slit experiments.

Footnotes

1

Figures in brackets indicate the literature references at the end of this paper.

2

The asymmetric distribution of wavelength points apparent in figure 3 is, to some extent, unavoidable unless an excessive number of uniformly spaced wavelengths is used because of the dependence of the line shift upon the radial position of the observation.

3

This includes a correction discussed by Griem (26) to the ionization potential lowering.

4

There appears to be an error in the equation for self-absorption in reference 2 (eq (6)). gn should probably be replaced by 12π.

6. References

  • [1].Pery-Thorne A. and Chamberlain J. E.. Proc. Phys. Soc. (London) 82,133 (1963). [Google Scholar]
  • [2].Olsen H. N., J. Quant. Spectr. Radiative Transfer 3, 59 (1963). [Google Scholar]
  • [3].Gericke W. E., Z. Astrophysik 53, 68 (1961). [Google Scholar]
  • [4].Drawin H. W., Z. Physik 146, 295 (1956). [Google Scholar]
  • [5].Wiese W. L. and Shumaker J. B. Jr., J. Opt. Soc. Am. 51, 937 (1961). [Google Scholar]
  • [6].Shumaker J. B. Jr., Rev. Sci. Instr. 32, 65 (1961). [Google Scholar]
  • [7].Yokley C. R. and Shumaker J. B. Jr., Rev. Sci. Instr. 32, 6 (1961). [Google Scholar]
  • [8].Paquette D. R. and Wiese W. L., Applied Optics 3, 291 (1964).. [Google Scholar]
  • [9].Griem H. R., Plasma Spectroscopy (McGraw-Hill Book Co., New York, N.Y., 1964). [Google Scholar]
  • [10].Freeman M. P. and Katz S., J. Opt. Soc. Am. 50, 826 (1960). [Google Scholar]
  • [11].Freeman M. P. and Katz S., J. Opt. Soc. Am. 53, 1172 (1963). [Google Scholar]
  • [12].Erdelyi A., Higher Transcendental Functions, Vol. 2 (McGraw-Hill Book Co., New York, N.Y., 1953). [Google Scholar]
  • [13].Herlitz S. I., Arkiv for Fysik. 23, 571 (1963). [Google Scholar]
  • [14].Griem H. R., Kolh A. C., and Slien K. Y., Astrophys. J. 135, 422 (1962)., [Google Scholar]
  • [15].Griem H. R., Astrophys. J. 136, 422 (1962). [Google Scholar]
  • [16].Shumaker J. B. Jr., and Wiese W. L., Temperature — Its Measurement and Control in Science and Industry, Vol. 3, Pt. 1, pp. 575–579, (Reinhold Pub. Corp., New York, N.Y., 1962). [Google Scholar]
  • [17].Drellishak K. S., Knopp C. F., and Cambel A. B., Arnold Engineering Development Center Tech. Documentary Report AEDOTDR-63-146 (1962).
  • [18].Griem H. R.. Phys. Rev. 128, 997 (1962). [Google Scholar]
  • [19].Yokley C. R. and Shumaker J. B., Rev. Sci., Instr. 34, 551 (1963). [Google Scholar]
  • [20].DeVos J. C., Physica 20, 690 (1954) [Google Scholar]
  • [21].Roder O. and Stampa A., Z. Physik 178, 348(1964). [Google Scholar]
  • [22].Griem H. R., Phys. Rev. 131, 1170 (1963). [Google Scholar]
  • [23].Garstang R. H., Men. Not. R. Astr. Soc 114, 118 (1954). [Google Scholar]
  • [24].N.B.S. Tech. News Bull. 49, 14 (1965). [Google Scholar]
  • [25].Wiese W. L., Paquette D. R., and Solarski J. E., Phys. Rev. [Google Scholar]
  • [26].Griem H. R., Phys, Rev. 128, 515 (1962). [Google Scholar]
  • [27].Richter J.. Z. Astrophysik 53, 262 (1961). [Google Scholar]
  • [28].Larenz R. W. and Bartels H., Naturwiss. 37, 164 (1950). [Google Scholar]

Articles from Journal of Research of the National Bureau of Standards. Section A, Physics and Chemistry are provided here courtesy of National Institute of Standards and Technology

RESOURCES