Abstract
Background
Mammography (MG) is highly sensitive for detecting microcalcifications, but has low specificity. This study investigates whether establishing a preoperative nomogram including ultrasonographic findings can help predict the likelihood of malignancy in patients with mammographic microcalcification.
Methods
Between May 2012 and January 2017, 475 patients with suspicious microcalcifications detected on MG underwent ultrasonography (US). The χ2 test was used to screen risk factors among the variables. Then, a multivariate logistic regression analysis was performed to identify independent predictors of malignant microcalcifications. A mammographic nomogram (M nomogram) and mammographic-ultrasonographic nomogram (M-U nomogram) were established based on multivariate logistic regression models. The discriminatory ability and clinical utility of both nomograms were compared by the receiver operating characteristics curve and decision curve analysis. The calibration ability was evaluated using a calibration curve.
Results
Among the cases, 68.2% (324/475) were pathologically diagnosed as breast cancer and 31.8% (151/475) were benign lesions. Based on multivariate logistic regression analysis, age, clinical manifestation, morphology and distribution of microcalcifications on MG and lesions associated with microcalcifications on US were confirmed as independent predictors of malignant microcalcifications. In terms of discrimination ability, the C-index of the M-U nomogram was significantly higher than that of the M nomogram (0.917 vs 0.897, p = 0.006). The bias-corrected curve was close to the ideal line in the calibration curve. Decision curve analysis suggested that the M-U nomogram was superior to M nomogram.
Conclusions
Combining mammographic parameters with ultrasonographic findings in a nomogram provided better performance than an M nomogram alone, especially for dense breasts, which suggests the value of ultrasonographic finding for individualized prediction of malignancy in patients with microcalcifications.
Keywords: Breast, Microcalcification, Ultrasonography, Nomogram, Mammography
Background
Mammography (MG) is highly sensitive for detecting microcalcifications but has low specificity. Only 12.3–42.0% of microcalcifications detected by MG are pathologically proven to be malignant after surgery [1–5]. To appropriately manage patients, the 5th edition of Breast Imaging Reporting and Data System (BI-RADS) suggested subdivisions based on the morphology of suspicious microcalcifications. The guideline indicated that amorphous, coarse heterogeneous, and fine pleomorphic cases should be assessed as category 4B (positive predictive value range: 10–50%), whereas fine linear or fine-linear branching should be assessed as category 4C (positive predictive value range: 50–95%) [6]. However, BI-RADS provides only a range and not exact values of the malignant likelihood of microcalcifications based on morphology. Additionally, unlike morphology, it does not provide recommendations regarding the distribution of suspicious microcalcifications, despite studies showing that the distribution is helpful for predicting malignancy risk [1–5]. Furthermore, combining morphology and distribution descriptors for suspicious microcalcifications has been suggested to provide a more accurate risk stratification [2].
In addition to MG, ultrasonography (US) is one of the most widely available diagnostic options for women with breast tumors [7]. Previous studies have confirmed that malignant microcalcifications are more easily detectable on US than benign microcalcifications [8, 9], and that the visibility of masses on US corresponding to areas of microcalcifications is much higher for highly suspicious microcalcifications [9, 10]. However, no studies have reported differences in the diagnosis of microcalcifications between MG alone and the combination of MG and US. Thus, whether the combined analysis of mammographic features and ultrasonographic findings associated with microcalcifications can better predict the likelihood of malignancy in patients with microcalcifications detected by MG is unknown.
Recently, nomograms which create a simple graphical representation of a predictive statistical model [11], have become widely used as predictive tools for diagnosing malignancies. Timmers et al [12] developed a nomogram for breast cancer based on common mammographic findings on screening mammograms. In addition, Park et al [13] developed a nomogram for predicting underestimation of invasiveness in ductal carcinoma in situ diagnosed by preoperative needle biopsy. These studies suggest that nomograms could be developed for the individualized prediction of malignant microcalcifications. Thus, the purpose of this study was to investigate whether establishing a preoperative nomogram including ultrasonographic findings can help predict the likelihood of malignancy in patients with microcalcifications.
Methods
Study population
Our institutional review board approved this retrospective study and waived the requirement for informed consent. We retrospectively reviewed consecutive mammograms taken between May 2012 and January 2017. Suspicious microcalcifications (BI-RADS 4 and 5) without other abnormalities were detected on MG in 570 patients who underwent MG because of symptoms (palpable mass or nipple discharge, 389 patients) or opportunistic screening (181 women). We excluded patients who had undergone prior biopsy (n = 83, 62 with symptom and 21 for screening) and patients whose digital images were unavailable for review (n = 12, 6 symptomatic and 6 screening). At our institution, breast US is a routine examination for women with breast disease. Thus, a total of 475 lesions from 475 patients (321 with symptom and 154 for screening) were selected from 570 patients in this study (Fig. 1). The median patient age was 45 years (range: 21–79 years).
Imaging acquisition and analysis
Bilateral digital mammograms with two standard imaging planes (mediolateral oblique and craniocaudal) were obtained using a digital mammographic unit (Planmed Nuance; Planmed, Helsinki, Finland). Breast US examinations were performed with a high-resolution US unit (S2000 or S1000; Siemens Medical Solutions, Erlangen, Germany). All US examinations were performed by one of seven dedicated breast radiologists with a minimum of 3 years of experience. Our radiologists were exclusively devoted to mammographic diagnoses and US scanning and diagnoses, and the US scanning and diagnosis of individual patients were performed by the same radiologist. When suspicious microcalcifications on MG were found before US, the radiologist scanned both whole breasts and focused on the area of microcalcifications. In six patients, when suspicious microcalcifications on MG were found after negative US finding, a “second-look” US scan focused on the area of microcalcifications was performed and microcalcifications were identified in 4 patients. Mammograms and ultrasonograms were simultaneously reviewed by two breast imaging radiologists who were blinded to pathological information but not clinical information. When descriptors differed between two radiologists, consensus was reached after discussion.
Mammograms were reviewed for breast composition and the morphology and distribution of microcalcification according to the BI-RADS Atlas [6]. The morphologies of microcalcifications were divided into two categories: amorphous/coarse heterogeneous or fine pleomorphic/fine linear and fine-linear branching. Additionally, the distributions were divided into two categories: regional/grouped or segmental/linear.
Ultrasonograms corresponding to the microcalcification area on MG and medical records were reviewed for whether the microcalcifications were visible and lesions associated with the microcalcifications which included masses or cysts. A negative finding was recorded when no lesions were found on US.
Clinical analysis and biopsy
Clinical information, including age and clinical manifestations, was also included in our study. These data were obtained from medical records. Age was divided into three groups: < 40 years, 40–55 years, and > 55 years. Clinical manifestations were classified as palpable mass, nipple discharge, and asymptomatic.
Pathological results, including malignant and benign lesions, were also obtained from medical records. US-guided biopsies (core biopsy with a 14-gauge needle) were performed when microcalcifications were visible on US. Specimen radiography was performed to ensure that the microcalcifications were sampled. Patients with B3 (uncertain malignant potential), B4 (suspicious) or B5 (malignant) biopsy results were referred for open surgery. Patients with benign histopathological findings were referred for vacuum-assisted or surgical excision or follow up. MG-guided wire localization with surgical excision biopsy and specimen radiography were performed when microcalcifications were not found on US. Patients with malignant intraoperative pathological results were referred for breast conservation treatment or modified mastectomy. Patients with benign histopathological findings had a minimum of 12 months follow-up after US- or MG-guided biopsy or surgery. Follow-up data were queried through April 2, 2018.
Statistical analysis
The χ2 test was used to screen risk factors from variables. Then, a multivariate logistic regression analysis was performed to identify the independent predictors of malignant microcalcifications. The mammographic nomogram (M nomogram) and mammographic-ultrasonographic nomogram (M-U nomogram) were established to predict the likelihood of malignancy in patients with microcalcifications given the predictors in the final multivariable model. The discrimination, calibration ability, and clinical usefulness were used to evaluate the model’s performance. The discriminative abilities of both nomograms were quantified by ROC curve and concordance index (C-index) measures. The calibration curve and Hosmer–Leme-show goodness-of-fit test were used to determine the calibration ability of the model. Decision curve analysis (DCA) was executed to assess the clinical utility of both nomograms by quantifying the net benefits for a range of threshold probabilities. P < 0.05 was indicative of a statistically significant difference. Stata/MP version 13.0 (StataCorp LP, College Station, TX, USA) and R software version 3.3.2 were used to conduct all statistical analyses.
Results
Pathological results
Among the 475 cases (321 symptomatic and 154 screening) selected from 570 patients (389 symptomatic and 181 screening), 324 (68.2%) were malignant, while 151 (31.8%) were benign. Pathological results are shown in Table 1.
Table 1.
Pathological Results | Patients (n) | Percent (%) |
---|---|---|
Malignant | 324 | 68.2 |
IDC | 211 | 44.4 |
DCIS | 111 | 23.4 |
ILC | 2 | 0.4 |
Benign | 151 | 31.8 |
Fibrocystic change | 39 | 8.2 |
Adenosis | 34 | 7.2 |
Ductal hyperplasia without atypia | 32 | 6.7 |
Atypical ductal hyperplasia | 16 | 3.4 |
Papilloma | 12 | 2.5 |
Fibroadenoma | 11 | 2.3 |
Radial scar/ complex sclerosing lesion | 7 | 1.5 |
IDC invasive ductal carcinoma, DCIS ductal carcinoma in situ, ILC invasive lobular carcinoma
Predictors of malignant microcalcifications
Predictors associated with a higher likelihood of malignant microcalcifications in the χ2 test included age, clinical manifestation, morphology and distribution of microcalcifications on MG, whether the microcalcifications were visible, and lesions associated with the microcalcifications on US (Table 2). Sequentially, considering the multivariate logistic regression analysis, age, clinical manifestation, morphology and distribution of microcalcifications on MG, and lesions associated with microcalcifications on US were confirmed to be independent predictors of malignant microcalcifications (Table 2).
Table 2.
Variables | Cancer (n=324) | Benign (n=151) | χ2 test | Multivariate analysis | |
---|---|---|---|---|---|
P Value | P Value | OR (95%CI) | |||
Age (y) | 0.005 | ||||
<40 | 80 (24.7) | 43 (28.5) | Reference | ||
40-55 | 189 (58.3) | 99 (65.5) | 0.026 | 2.12 (1.10,4.09) | |
>55 | 55 (17.0) | 9 (6.0) | 0.004 | 5.17 (1.71, 15.61) | |
Clinical manifestation | <0.001 | ||||
Mass/nipple discharge | 285 (88.0) | 36 (23.8) | Reference | ||
Asymptomatic | 39 (12.0) | 115 (76.2) | <0.001 | 0.11 (0.05, 0.21) | |
Breast composition | 0.237 | ||||
a + b | 19 (5.9) | 5 (3.3) | |||
c + d | 305 (94.1) | 146 (96.7) | |||
Morphology | <0.001 | ||||
Amorphous/coarse heterogeneous | 112 (34.6) | 101 (66.9) | Reference | ||
Fine pleomorphic/fine linear and fine-linearbranching | 212 (65.4) | 50 (33.1) | <0.001 | 3.67 (2.05, 6.59) | |
Distribution | <0.001 | ||||
Regional/grouped | 244 (75.3) | 138 (91.4) | Reference | ||
Segmental/linear | 80 (24.7) | 13 (8.6) | 0.002 | 4.51 (1.77, 11.50) | |
Microcalcifications on USa | <0.001 | ||||
Yes | 301 (92.9) | 85 (56.3) | Reference | ||
No | 23 (7.1) | 66 (43.7) | 0.766 | 1.15 (0.46, 2.89) | |
Lesions on US b | <0.001 | ||||
Mass | 300 (92.6) | 51 (33.8) | Reference | ||
Cyst/normal | 24 (7.4) | 100 (66.2) | <0.001 | 0.12 (0.05, 0.30) |
Note: Data are numbers of patients, with percentages in parentheses
OR odds ratio
a whether microcalcifications were visible on US
b lesions associated with microcalcifications on US
Development of the nomograms
Based on the multivariate analysis results, the M nomogram was constructed to predict the likelihood of malignant microcalcifications using four independent predictors (age, clinical manifestation, morphology, and distribution of microcalcifications on MG) (Fig. 2). The M-U nomogram was developed to predict the likelihood of malignant microcalcifications using five independent factors (age, clinical manifestation, morphology and distribution of microcalcifications on MG and lesions associated with the microcalcifications on US) (Fig. 3).
Performance of the M nomogram and M-U nomogram
ROC curves and C-index values were used to test the two nomograms (Fig. 4). The C-index of the M nomogram was 0.897 (95% CI: 0.868–0.927), and the C-index of the M-U nomogram was 0.917 (95% CI: 0.891–0.942). In terms of their discriminatory abilities, the C-index of the M-U nomogram was significantly higher than that of the M nomogram (0.917 vs 0.897, p = 0.006). The calibration of the M-U nomogram was performed via a calibration curve (Fig. 5). The bias-corrected curve was close to the ideal line in the calibration curve. The p-value of the Hosmer–Leme-show goodness-of-fit test was 0.694. The DCAs of the two nomograms are shown in Fig. 6. With respect to their clinical utility, DCA suggested that the M-U nomogram was superior to the M nomogram across a wider range of threshold probabilities.
Discussion
In our study, 68.2% of microcalcifications were pathologically diagnosed as breast cancer, and invasive ductal carcinoma was the most common malignant diagnosis (65.1%, 211/324). However, previous studies reported that the positive predictive value of microcalcifications was 12.3–42.0% and that ductal carcinoma in situ was the most common malignant diagnosis [1–5]. The reason for these discrepancies may be differences in the criteria for the inclusion of patients. The previous studies only included asymptomatic patients, whereas our study included asymptomatic patients and patients with a palpable mass or nipple discharge. Park et al [13] reported that a clinically palpable mass suggested invasive cancer.
In this study, we established an M-U nomogram to predict the risk of malignancy in patients with microcalcifications. The C-index of the M-U nomogram was higher than that of the M nomogram (0.917 vs 0.897, p = 0.006). Obviously, the discriminatory ability of the M-U nomogram improved when the M nomogram was incorporated along with ultrasonographic findings. The bias-corrected curve was close to the ideal line, which showed that the M-U nomogram was well calibrated. Moreover, DCA demonstrated that the M-U nomogram had good clinical usefulness. Therefore, the M-U nomogram could predict the likelihood of malignancy in patients with microcalcifications with high discrimination, high calibration ability, and robust clinical utility. Finally, we showed that age, clinical manifestation, the morphology and distribution of microcalcifications on MG, and lesions associated with microcalcifications on US were independent predictors of malignant microcalcifications.
In this study, the rate of malignant microcalcifications increased with increasing age (OR = 2.12 in the 40 to 55-year-old cohort and OR = 5.17 in the > 55-year-old cohort). Farshid et al. [14] also reported that older women had a higher rate of malignancy (41.7% in the 40 to 49-year-old cohort, 48.1% in the 50 to 59-year-old cohort, 48.3% in the 60 to 69-year-old cohort, and 56.5% in the > 70-year-old cohort); however, in their study, age was not an independent predictor. The age peak in our study was between 40 and 55 years, which is consistent with a report that the peak age of breast cancer onset is between 45 to 55 years in China [15]. Apart from age, it is also necessary to record clinical manifestation before MG. Especially in China, clinical manifestation was often missing because of the large number of patients. Compared with asymptomatic women, patients with palpable masses or nipple discharge were more likely to show malignant microcalcifications (P < 0.001). Farshid et al. [14] reported that when a palpable mass was associated with microcalcifications, the microcalcifications had a higher rate of malignancy. The cause of pathologic nipple discharge is primarily benign lesions, but there is still a possibility of malignancy [16]. Pathologic nipple discharge patients with breast microcalcifications had a higher risk of breast cancer than those without breast calcifications (p = 0.000) [17].
On MG, the morphology and distribution of microcalcifications were helpful for predicting malignant risk, as was found in previous studies [1–5, 18]. Moreover, in both previous studies and our study, the morphology and distribution descriptors showed an increasing trend toward malignancy from amorphous/coarse heterogeneous to fine pleomorphic/fine linear/fine-linear branching microcalcifications and from regional/grouped to segmental/linear [1–4]. In addition to asymptomatic patients, our study included patients with a palpable mass or nipple discharge. However, microcalcifications were the only abnormality found on mammogram. For the detection of a palpable mass, breast density is the strongest predictor for mammography failure [19]. Mammographic sensitivity declines significantly with increasing breast density [20–23], from a level of 85.7–88.2% in women with almost entirely fatty breasts to 62.2–68.1% in women with extremely dense breasts [22, 23]. In our study, 94.9% (451/475) of patients had heterogeneously or extremely dense breasts. Dense breast may lead masking of a palpable mass on mammography. For microcalcification biopsy, mammography-guided stereotactic vacuum assisted biopsy is a reliable, safe and accurate method for tissue sampling and evaluation of breast lesion including suspicious microcalcifications [24–26]. However, the stereotactic guided biopsy device was not available in our institute. Consequently, MG-wire guided localization with surgical excision biopsy and specimen radiography were performed.
Compared with MG, US cannot be used alone for diagnosing microcalcifications. However, it is helpful for predicting malignant risk [8–10]. As reported by Moon et al. [10], masses associated with microcalcifications on US were confirmed to be an independent predictor of malignant microcalcifications. Moon reported that US depicted more breast masses associated with malignant than with benign microcalcifications (82%, 31/38 vs 23%, 14 /62, P < 0.001), while the proportion of breast masses associated with malignant and benign microcalcifications identified by US in our study was 92.6% (300/324) and 33.8% (52/151) (P < 0.001), respectively.
Our study had some limitations. First, a validation group was absent because of the retrospective nature of this small-sample study. However, DCA demonstrated that the M-U nomogram had good clinical usefulness. Second, the extent of microcalcifications was not considered, because, according to BI-RADS, the distribution of microcalcifications considers the extent. For example, 2 cm is the boundary between the regional and the group distribution. Therefore, the extent and distribution of microcalcifications are not independent of each other. Third, we did not perform comparisons with old films, because we included only patients with first mammogram. And, we hoped that the establishment of a nomogram would contribute to the initial diagnosis of breast microcalcifications.
Conclusions
In conclusion, combining mammographic parameters with ultrasonographic findings in a nomogram provided better performance than an M nomogram alone, especially for dense breast, which suggests the value of ultrasonographic findings for individualized prediction of malignancy in patients with microcalcifications.
Acknowledgements
We wish to acknowledge Cui Tan for her valuable assistance in the classification of pathological results.
Abbreviations
- BI-RADS
Breast imaging reporting and data system
- C-Index
Concordance index
- DCA
Decision curve analysis
- M nomogram
Mammographic nomogram
- MG
Mammography
- M-U nomogram
Mammographic-ultrasonographic nomogram
- US
Ultrasonography
Authors’ contributions
FS, HW and JL (Jianguo Lai) conceived of the idea. HW and JL (Jianguo Lai) designed the study. HW and JL (Jiao Li) made substantial contributions to acquisition of data. HW and JL (Jianguo Lai) performed the analysis and interpretation of data. HW and JL (Jianguo Lai) drafted the manuscript. FY and FS revised the manuscript. RG, FL, YH, JM, XJ and SS participated in proofreading data. HW and JL (Jianguo Lai) contributed equally to this study, they are listed as dual first authors. FY and FS contributed equally to this study, they are listed as dual corresponding authors. All the authors read and approved the final manuscript.
Funding
This work was supported by the national natural science foundation of China (81372817).
Availability of data and materials
The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.
Ethics approval and consent to participate
This study was approved by our institutional review board.
Consent for publication
Our institutional review board waived the requirement for written informed consent.
Competing interests
The authors declare that they have no competing interests.
Footnotes
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Hongli Wang and Jianguo Lai are contributed equally to this work and dual first authors.
Contributor Information
Hongli Wang, Email: wanghli5@mail.sysu.edu.cn.
Jianguo Lai, Email: laijg@mail2.sysu.edu.cn.
Jiao Li, Email: lijiao@sysucc.org.cn.
Ran Gu, Email: guran3@mail.sysu.edu.cn.
Fengtao Liu, Email: liufenphoto@163.com.
Yue Hu, Email: huyue57@mail.sysu.edu.cn.
Jingsi Mei, Email: meijs@mail.sysu.edu.cn.
Xiaofang Jiang, Email: jiang970946396@126.com.
Shiyu Shen, Email: curtis652@icloud.com.
Fengyan Yu, Phone: (0086) 18998460695, Email: sakya.vir@foxmail.com.
Fengxi Su, Phone: (0086) 15989193461, Email: fengxisu@vip.163.com.
References
- 1.Youk JH, Son EJ, Kim JA, Moon HJ, Kim MJ, Choi CH, et al. Scoring system based on BI-RADS lexicon to predict probability of malignancy in suspicious microcalcifications. Ann Surg Onco. 2012;19:1491–1498. doi: 10.1245/s10434-011-2167-4. [DOI] [PubMed] [Google Scholar]
- 2.Kim SY, Kim HY, Kim EK, Kim MJ, Moon HJ, Yoon JH. Evaluation of malignancy risk stratification of microcalcifications detected on mammography: a study based on the 5th edition of BI-RADS. Ann Surg Oncol. 2015;22:2895–2901. doi: 10.1245/s10434-014-4362-6. [DOI] [PubMed] [Google Scholar]
- 3.Burnside ES, Ochsner JE, Fowler KJ, Fine JP, Salkowski LR, Rubin DL, et al. Use of microcalcification descriptors in BI-RADS 4th edition to stratify risk of malignancy. Radiology. 2007;242:388–395. doi: 10.1148/radiol.2422052130. [DOI] [PubMed] [Google Scholar]
- 4.Bent CK, Bassett LW, D'Orsi CJ, Sayre JW. The positive predictive value of BI-RADS microcalcification descriptors and final assessment categories. AJR Am J Roentgenol. 2010;194:1378–1383. doi: 10.2214/AJR.09.3423. [DOI] [PubMed] [Google Scholar]
- 5.Liberman L, Abramson AF, Squires FB, Glassman JR, Morris EA, Dershaw DD. The breast imaging reporting and data system: positive predictive value of mammographic features and final assessment categories. AJR Am J Roentgenol. 1998;171:35–40. doi: 10.2214/ajr.171.1.9648759. [DOI] [PubMed] [Google Scholar]
- 6.Sickles EA, D’Orsi CJ, Bassett LW, et al. ACR BI-RADS mammography. In: ACR BI-RADS Atlas, Breast Imaging Reporting and Data System. Reston, VA, American College of Radiology, 2013.
- 7.Berg WA. Current status of supplemental screening in dense breasts. J Clin Oncol. 2016;34:1840–1843. doi: 10.1200/JCO.2015.65.8674. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Gufler H, Buitrago-Téllez CH, Madjar H, Allmann KH, Uhl M, Rohr-Reyes A. Ultrasound demonstration of mammographically detected microcalcifications. Acta Radiol. 2000;41:217–221. doi: 10.1080/028418500127345370. [DOI] [PubMed] [Google Scholar]
- 9.Soo MS, Baker JA, Rosen EL. Sonographic detection and sonographically guided biopsy of breast microcalcifications. AJR Am J Roentgenol. 2003;180:941–948. doi: 10.2214/ajr.180.4.1800941. [DOI] [PubMed] [Google Scholar]
- 10.Moon WK, Im JG, Koh YH, Noh DY, Park IA. US of mammographically detected clustered microcalcifications. Radiology. 2000;217:849–854. doi: 10.1148/radiology.217.3.r00nv27849. [DOI] [PubMed] [Google Scholar]
- 11.Iasonos A, Schrag D, Raj GV, Panageas KS. How to build and interpret a nomogram for cancer prognosis. J Clin Oncol. 2008;26:1364–1370. doi: 10.1200/JCO.2007.12.9791. [DOI] [PubMed] [Google Scholar]
- 12.Timmers JM, Verbeek AL, IntHout J, Pijnappel RM, Broeders MJ, den Heeten GJ. Breast cancer risk prediction model: a nomogram based on common mammographic screening findings. Eur Radiol. 2013;23:2413–2419. doi: 10.1007/s00330-013-2836-8. [DOI] [PubMed] [Google Scholar]
- 13.Park HS, Kim HY, Park S, Kim EK, Kim SI, Park BW. A nomogram for predicting underestimation of invasiveness in ductal carcinoma in situ diagnosed by preoperative needle biopsy. Breast. 2013;22:869–873. doi: 10.1016/j.breast.2013.03.009. [DOI] [PubMed] [Google Scholar]
- 14.Farshid G, Sullivan T, Downey P, Gill PG, Pieterse S. Independent predictors of breast malignancy in screen-detected microcalcifications: biopsy results in 2545 cases. Br J Cancer. 2011;105:1669–1675. doi: 10.1038/bjc.2011.466. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Chen W, Sun K, Zheng R, Zeng H, Zhang S, Xia C, et al. Cancer incidence and mortality in China, 2014. Chin J Cancer Res. 2018;30:1–12. doi: 10.21147/j.issn.1000-9604.2018.01.01. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Chen L, Zhou WB, Zhao Y, Liu XA, Ding Q, Zha XM, et al. Bloody nipple discharge is a predictor of breast cancer risk: a meta-analysis. Breast Cancer Res Treat. 2012;132:9–14. doi: 10.1007/s10549-011-1787-5. [DOI] [PubMed] [Google Scholar]
- 17.Yang L, Wu D, Fan ZM. Retrospective analysis of pathologic nipple discharge. Genet Mol Res. 2015;14:1443–1449. doi: 10.4238/2015.February.13.23. [DOI] [PubMed] [Google Scholar]
- 18.Berg WA, Arnoldus CL, Teferra E, Bhargavan M. Biopsy of amorphous breast calcifications: pathologic outcome and yield at stereotactic biopsy. Radiology. 2001;221:495–503. doi: 10.1148/radiol.2212010164. [DOI] [PubMed] [Google Scholar]
- 19.Häberle L, Fasching PA, Brehm B, Heusinger K, Jud SM, Loehberg CR, et al. Mammographic density is the main correlate of tumors detected on ultrasound but not on mammography. Int J Cancer. 2016;139:1967–1974. doi: 10.1002/ijc.30261. [DOI] [PubMed] [Google Scholar]
- 20.Hooley RJ, Greenberg KL, Stackhouse RM, Geisel JL, Butler RS, Philpotts LE. Screening US in patients with mammographically dense breasts: initial experience with Connecticut public act 09-41. Radiology. 2012;265:59–69. doi: 10.1148/radiol.12120621. [DOI] [PubMed] [Google Scholar]
- 21.Kolb TM, Lichy J, Newhouse JH. Comparison of the performance of screening mammography, physical examination, and breast US and evaluation of factors that influence them: an analysis of 27,825 patient evaluations. Radiology. 2002;225:165–175. doi: 10.1148/radiol.2251011667. [DOI] [PubMed] [Google Scholar]
- 22.Carney PA, Miglioretti DL, Yankaskas BC, Kerlikowske K, Rosenberg R, Rutter CM, et al. Individual and combined effects of age, breast density, and hormone replacement therapy use on the accuracy of screening mammography. Ann Intern Med. 2003;138:168–175. doi: 10.7326/0003-4819-138-3-200302040-00008. [DOI] [PubMed] [Google Scholar]
- 23.Kerlikowske K, Hubbard RA, Miglioretti DL, Geller BM, Yankaskas BC, Lehman CD, et al. Comparative effectiveness of digital versus film-screen mammography in community practice in the United States: a cohort study. Ann Intern Med. 2011;155:493–502. doi: 10.7326/0003-4819-155-8-201110180-00005. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Kettritz U, Rotter K, Schreer I, Murauer M, Schulz-Wendtland R, Peter D, et al. Stereotactic vacuum-assisted breast biopsy in 2874 patients: a multicenter study. Cancer. 2004;100:245–251. doi: 10.1002/cncr.11887. [DOI] [PubMed] [Google Scholar]
- 25.Kettritz U, Morack G, Decker T. Stereotactic vacuum-assisted breast biopsies in 500 women with microcalcifications: radiological and pathological correlations. Eur J Radiol. 2005;55:270–276. doi: 10.1016/j.ejrad.2004.10.014. [DOI] [PubMed] [Google Scholar]
- 26.Kumaroswamy V, Liston J, Shaaban AM. Vacuum assisted stereotactic guided mammotome biopsies in the management of screen detected microcalcifications: experience of a large breast screening Centre. J Clin Pathol. 2008;61:766–769. doi: 10.1136/jcp.2007.054130. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.