Skip to main content
Journal of Research of the National Bureau of Standards. Section A, Physics and Chemistry logoLink to Journal of Research of the National Bureau of Standards. Section A, Physics and Chemistry
. 1968 May-Jun;72A(3):261–267. doi: 10.6028/jres.072A.025

Absolute Isotopic Abundance Ratios of Common, Equal-Atom, and Radiogenic Lead Isotopic Standards

E J Catanzaro 1, T J Murphy 1, W R Shields 1, E L Garner 1
PMCID: PMC6624684  PMID: 31824095

Abstract

Absolute values have been obtained for the isotopic abundance ratios of common, equal-atom, and radiogenic lead isotopic standards using solid-sample mass spectrometry. Samples of known 208Pb/206Pb ratio, prepared from nearly pure separated 206Pb and 208Pb solutions, were used to calibrate the mass spectrometers.

Keywords: Absolute ratios, abundance, isotopic standards, lead

1. Introduction

The NBS is conducting a long-term program of absolute isotopic abundance ratio and physical atomic weight determinations, using solid-sample mass spectrometry. Previous elements studied include silver [1],1 chlorine [2], copper [3], bromine [4], chromium [5], and magnesium [6]. The present work extends the study to lead.

The extreme isotopic variability of natural lead is well authenticated. It results from the fact that 206Pb, 207Pb, and 208Pb are continually being formed by the decay of 238U, 235U, and 232Th, respectively. 204Pb is nonradiogenic and is used as a fiduciary mark for the separation of the “common” and “radiogenic” portions of natural lead samples. A full discussion of natural lead isotope abundance variations is given by Russell and Farquhar [7].

The purpose of the present study was to establish the absolute isotopic compositions of three lead standards which cover the usual range of natural isotopic values, so that all future lead isotope measurements could be put on an absolute scale. Previous measurements, by numerous laboratories throughout the world, could only be considered relative because there has been no systematic attempt to calibrate instruments and techniques.

In addition, the NBS standard samples, which are distributed for a relatively nominal fee (see appendix), are very high purity lead metal and may also be used as gravimetric standards.

A preliminary study, which was concerned only with the determination of the absolute isotopic compositions of three common lead samples used as references by geochemists, has already been published [8].

The mass spectrometers used in this study were calibrated for bias by the use of samples of known 208Pb/206Pb ratio prepared from nearly pure separated 206Pb and 208Pb solutions. The collector and recorder systems used in this laboratory have been designed so that any biases they might contribute are constant. The only “random” bias associated with the isotopic ratio measurements is due to the mass-dependent fractionation of the isotopes during ionization, and this bias is independent of the isotopic composition of the samples. Thus, for each instrumental system used in this study, a single experimentally determined correction factor is valid over the entire range of isotopic compositions measured.

The fact that each mass spectrometer used in this study requires only a single correction factor for source discrimination has been proven by numerous systems calibrations performed mainly with a series of uranium-isotope standards (see appendix), with 235U/238U ratios ranging from 1/20 to 20/1. A “systems” calibration, as opposed to a “point” calibration in which only one isotopic ratio standard is used, is always necessary for an instrument which is to be used on an element with more than one isotopic ratio. In this laboratory a uranium-isotope systems calibration is performed on each instrument as soon as it is completed, or modified, and before it is ever used in a research project. In addition, whenever feasible, a partial systems calibration is also performed with widely differing isotopic standards of the element under study. For example, partial systems calibrations have been performed with copper [3] and magnesium [6]. In the present study the systems calibration was rechecked and verified by comparing the results for calibration mixes with 208Pb/206Pb = 1.0 and 208Pb/206Pb = 2.1. It is not practicable to prepare standards of more than two isotopes, because the propagation of isotopic composition uncertainty involved in mixing more than two isotope solutions would greatly decrease the accuracy of the calculated ratios.

2. Experimental Procedure

2.1. Mass Spectrometry

Isotopic measurements of the calibration mixes and standard samples were made with three different single-stage solid-sample mass spectrometers. Two instruments (#1 and #3), used by operator I, are identical in all aspects and the third (#2), used by operator II, differed only in that it has an in-line beam valve on the tube. All three instruments have a 12-in radius of curvature 68° analyzer tube and 60° sector magnet, and all three have Z-lenses in the source assembly [9]. Triple-filament sources were used; with rhenium-ribbon (1 × 30 mil) sample filaments and a platinum-ribbon (1 × 30 mil) ionizing filament [10].

The samples were prepared to a concentration of 25 mg of Pb per milliliter of 2 percent HNO3, and were mounted on the sample filaments by mixing, on the filaments, one drop each of the sample solution (~ 250 μg Pb) and of a 10 percent NH4OH solution. The precipitated Pb(OH)2 was dried with a heat lamp and a 1.2 A current (5 min). The mass spectrometric analysis was begun when the tube pressure was < 1 × 10−7 torr. An accelerating voltage of 10 kV was used and no memory or background signals were ever noted. Source assemblies were dismantled and cleaned between the analyses of the different groups of samples with widely differing isotopic compositions. A detailed description of the mass spectrometric procedure is given by Catanzaro [8].

A small amount of isotopic fractionation generally occurs during an analysis; the 208Pb/206Pb ratio generally increases by about 0.03 percent during the data-taking period of an analysis (24 min). To minimize the effect of this fractionation, all analyses were made in an identical manner; data were always taken during the same time interval, and the total lead ion signal was always kept within strict limits (3 to 5 × 10−11 A).

2.2. Preparation of the Separated Lead Isotope Solutions

Approximately 2 g each of electromagnetically separated lead isotopes, 206Pb and 208Pb, in the form of lead nitrate, Pb(NO3)2, were obtained from the Isotopes Division, Oak Ridge National Laboratory of the Union Carbide Nuclear Company. The 206Pb(NO3)2 was designated series JV, sample 1186(z); and the 208Pb(NO3)2 was designated series MA, sample 1456(a). The certificate of analysis accompanying each sample indicated a high degree of chemical purity. These samples were further analyzed by the Spectrochemical Analysis Section at the National Bureau of Standards by quantitiative emission spectrography. The results of the analyses are shown in table 1. Since the lead concentrations of solutions of the lead isotopes were to be determined by a method based on the precipitation of lead chromate (PbCrO4) only those elements forming relatively insoluble chromates would cause errors in the determinations. These were the elements for which quantitative values or limits of detection were established. It was estimated that the maximum possible contamination of the lead isotope samples would be 0.002 percent for the 206Pb isotope and 0.004 percent for the 208Pb isotope based on the sum of amounts of the detected elements and limits of detection for the others. These concentrations were too low to cause significant error in the lead determinations so it was not necessary to further purify the isotope samples.

Table 1.

Results of spectrochemical analysis of lead isotope samples

Quantitative (with standards) determinations of concentrations
Element 206Pb 208Pb Estimated limits of detection
ppm ppm ppm
Ag < 1 15 < 0.1
Ba 1
Bi 1
Cu < 1 < 1 < 0.1
Hg < 10
Tl 5
Zn 1

NOTES: …, not detected; <, less than.

Solutions of each separated lead isotope were prepared as follows: the lead isotope as lead nitrate (about 3.1 g) was dissolved in about 20 ml of water and 1 ml of ultrapure grade nitric acid was added to this solution. The resulting solution was filtered and the filtrate was transferred to a 100 ml volumetric flask whose neck had been cut off so that only about 1 cm remained. Enough water was added to bring the final volume to about 65 ml. The solution was thoroughly mixed by swirling for several minutes and the flask was sealed with a rubber serum septum. (The total weight of the flask, solution, and septum was kept below 100 g so that a semimicro balance could be used for weighings.)

The two solutions prepared in this manner were designated “Pb 206” solution and “Pb 208” solution, respectively.

2.3. Lead Concentration of the Separated Isotope Solutions

A search of the chemical literature has shown that there is a need for a high precision – high accuracy method for the determination of lead. A method has been developed which is based on the precipitation of lead chromate with a small excess of potassium dichromate and spectrophotometric determination of the excess chromate. This method takes advantage of the precise analysis of NBS Standard Reference Material 139b, potassium dichromate, which has been shown to be 99.977 ± 0.003 percent [11].

The flasks containing the solutions of the separated isotopes and a tare flask were placed in the case of a semimicro balance and allowed to stand overnight to insure thermal equilibrium. The flasks and contents were then weighed on the balance to ± 0.02 mg. Samples were withdrawn from each flask by inserting a platinum needle attached to a glass hypodermic syringe through the rubber septum and withdrawing the desired amount of solution. A second needle which just punctured the septum served as a vent. The syringe and needle were then washed with distilled water and the washings were combined with the withdrawn sample. The weight of the sample withdrawn was determined from the weight of the flask before and after withdrawal of solution.

Four samples of from 7.8 to 8.4 g each were withdrawn from each solution by this method for the purpose of determining the lead concentrations of the “Pb 206” solution and the “Pb 208” solution. Each sample was treated as follows: two milliliters of perchloric acid was added and the solution was evaporated to dryness at low heat on a hot plate. The residue was dissolved in a small amount of water and the resulting solution was again evaporated to dryness at low heat on a hot plate. This procedure completely freed the salt from nitrate ion which was found to interfere with the method by forming a lead-potassium-nitrate complex [12] which caused low results. The repeated evaporation also freed the salt from excess perchloric acid.

A 100 to 400 μg excess of potassium dichromate, K2Cr2O7, over the amount needed to stoichiometrically precipitate lead chromate, PbCrO4, was accurately weighed on a microbalance. The potassium dichromate used was NBS Standard Reference Material 139b which has been shown to have an assay value of 99.977 ± 0.003 percent [11]. This weight was corrected for assay of the K2Cr2O7 and for the bouyancy effect of air.

The potassium dichromate was transferred to a 100 ml beaker and dissolved in about 30 ml of water. This solution was titrated with dilute ammonium hydroxide (1 + 99) to convert dichromate ion, Cr2O7−−, to chromate ion, CrO4−−. The end point of this titration was noted by comparing the color to the yellow color of a potassium chromate solution of the same concentration. A Teflon enclosed magnetic stirring bar was added and the solution was stirred magnetically.

The solution containing the isotopic lead sample was slowly added to the chromate solution and the beaker was thoroughly washed into this solution. The pH of this solution was adjusted to 2.5 with (1 + 9) NH4OH and finally to between 4.5 and 6.5 with (1 + 99) NK4OH. The pH was monitored with a pH meter using a glass-calomel electrode system. The precipitate and solution was allowed to stand for 1 hr and then filtered through fine filter paper. The filtrate was caught in a 100 ml volumetric flask. After the precipitate was washed with a small volume of water, the filtrate was diluted to exactly 100 ml. One pellet of ACS grade potassium hydroxide, about 0.2 g, was added to produce an alkaline solution. The chromate concentration was determined by measuring the transmittancy of the solution at 367 nm (mu) of the solution in a 2-cm cell and comparing to a reference curve.

The millimoles (m mol) of lead present in the solution are equivalent to the millimoles of chromate added less the millimoles of chromate found in the filtrate. (The solubility of PbCrO4 under these conditions was found to be negligible.) Table 2 shows the results of these determinations.

Table 2.

Concentration of lead isotope solutions

Soln Sample No. Wt soln K2Cr2O7 Equivalent Conc. soln Pb/g soln
g mmol mmol
Pb206 A 7.99061 1.131165 0.1415618
B 8.24170 1.166716 .1415625
C 8.00613 1.133361 .1415617
D 7.86875 1.113944 .1415655
Average a 0.1415629
Pb208 A 8.42849 1.186636 0.1407887
B 7.85653 1.106099 .1407872
C 8.36411 1.177473 .1407768
D 8.27248 1.164649 .1407860
Average 0.1407847
a

The standard error of the average is calculated to be 0.00000405 mmol Pb/g soln and the uncertainty of the value of concentration at the 95 percent confidence level is 0.0000081 mmol Pb/g soln.

This method for determining the concentration of lead solutions was tested on solutions containing known amounts of lead. Nine such solutions, in the approximate concentration of the separated isotope solutions, were prepared from high purity lead containing less than 0.001 percent total detected metallic impurities. Four samples containing from 0.139 to 0.153 mmol of Pb were withdrawn from each solution and the lead ion concentrations were determined as described.

Data resulting from the analysis of these nine preliminary lead solutions showed that (a) the concentrations of these solutions as mmol Pb/g soln agreed to within 0.02 percent of the concentrations calculated, (b) a slight positive bias of 0.01 percent was detected but this would have a negligible effect on ratios, (c) the method was independent of sample size or concentration over the range studied, and (d) the analysis of the nine solutions were of equal precision.

Pooling the results of the analyses of the separated isotope solutions as shown in table 2 with the results from the nine sets described above yields a value of 0.0000081 mmol Pb/g soln for the standard deviation of an individual determination (33 deg of freedom). The standard error of the average of four determinations is therefore 0.00000812 or 0.00000405 mmol Pb/g soln. At the 95 percent confidence level this is equal to 2.04 × 0.00000405 or 0.000008 mmol Pb/g soln.

2.4. Isotopic Analysis of the Separated Isotope Solutions

The separated isotope solutions were analyzed four times each on two mass spectrometers (#2 and #3). The averaged results are given in table 3. In all of the analyses the amount of 204Pb could only be estimated because the signal was very small and could not be separated from possible baseline fluctuations with any degree of certainty. The isotopic compositions reported by ORNL are: “Pb 206”, < 0.01 atom percent 204Pb, 99.8 ± 0.02 atom percent 206Pb, 0.2 ± 0.02 atom percent 207Pb, and <0.03 atom percent 208Pb; “Pb 208”, <0.05 atom percent 204Pb, 0.19 ± 0.05 atom percent 206Pb, 0.52 ± 0.05 atom percent 207Pb, and 99.3 ± 0.05 atom percent 208Pb. The ORNL limits quoted express the precision of the measurements. From known sources of systematic error, the absolute error is estimated by ORNL to be less than 1 percent.

Table 3.

Isotopic composition of separated lead isotopes used in calibration samples

Separated isotope Isotopic composition (atom percent)
“Pb 206” 204Pb 0.0010
206Pb 99.7403 ± 0.0040a
207Pb 0.2299
208Pb .0288
“Pb 208” 204Pb 0.0010
206Pb .1930
207Pb .5057
208Pb 99.3003 ±0.0040
a

The uncertainties are based on a minimum error of 0.00002 for the ratio determinations. The calculated 95 percent confidence limits are well below this value.

2.5. Preparation of the Calibration Samples

Six calibration samples were prepared by mixing weighed portions of the “Pb 206” solution and the “Pb 208” solution to approximate the compositions of the three reference materials. The target 208/206 ratios were 2.16, 1.00, and 0.014. Two calibration samples were prepared for each target. However, since the errors associated with the preparation of mixes 7 and 8 (208/206 = 0.014) were large, they were not used for calibration purposes. Each calibration sample was thoroughly mixed by stirring and evaporated to dryness. The resulting Pb(NO3) was taken into solution with sufficient 2 percent HNO3 so that the lead concentration was 25 mg/ml. The compositions of these calibration samples are given in table 4.

Table 4.

Composition of lead calibration samples

Sample Isotope Wt soln Conc. soln Pb/g soln Pb
g m mol m mol
3 206 2.02622 0.1415629 0.2868376
208 2.08562 .1407847 .2936234
4 206 1.94738 0.1415629 0.2756768
208 1.97846 .1407847 .2785369
5 206 0.97453 0.1415629 0.1379573
208 2.10062 .1407847 .2957352
6 206 0.93376 0.1415629 0.1321858
208 2.04303 .1407847 .2876274
7 206 4.12812 0.1415629 0.5843886
208 0.05691 .1407847 .0080121
8 206 4.19283 0.1415629 0.5935492
208 0.06345 .1407847 .0089328

2.6. Isotopic Analyses of the Calibration Mixes and Standard Samples

Two complete sets of analyses of the calibration mixes and standard samples were made; one by operator I using instruments #1 and #3, and one by operator II using instrument #2. In the case of the common lead and equal atom standards, each set consisted of a total of eight analyses of the standard and four analyses each of the two appropriate calibration mixes (mixes 3 and 4 for the common lead, and mixes 5 and 6 for the equal atom lead), run in a simple alternating pattern. In the case of the radiogenic standard each set also consisted of a total of eight analyses of the standard and four analyses each of two calibration mixes (mixes 7 and 8). However, subsequent statistical evaluation of the data showed that both the chemical error in the preparation of these very low 208Pb/206Pb mixes and the error in the measurements (minimum error on a ratio = 0.00002) of these extreme ratios were too large, so that these mixes were essentially useless for calibration purposes. The principal source of the chemistry portion of the error was in the weighing and transferring of the small amounts of “Pb 208” solution (~ 60 mg). The results for these calibration mixes were therefore discarded and the final bias correction factor was calculated only on the basis of the four calibration mixes which had approximately the same 208Pb/206Pb values of either the common lead or equal atom standards.

In each standard sample analysis eight values each were obtained for the 204Pb/206Pb, 207Pb/206Pb, and 208Pb/206Pb ratios in the order: four values of 208Pb/206Pb, four values of 207Pb/206Pb, eight values of 204Pb/206Pb, four values of 207Pb/206Pb, and four values of 208Pb/206Pb. This pattern was followed so that the data was symmetrical to any fractionation effect. In the analyses of the calibration mixes, twenty-four measurements of the 208Pb/206Pb ratio were taken over the normal data-taking time interval of a standard sample analysis.

In all analyses, base-line readings were taken immediately before and after the data. The peak-top data were taken by step-wise changes in the magnet current and each peak-top was monitored for 30 sec.

3. Results and Discussion

Table 5 summarizes the results for the four calibration mixes. There is no statistically significant difference between any of the values. The seemingly large difference between operator II’s values for mixes 5 and 6 and mixes 3 and 4 is probably the result of either an operator bias in base-line readings or an attenuator error.

Table 5.

Determination of mass spectrometric bias

Calibration sample No. Isotopic ratio, 208Pb/206Pb Correction factor
Calculated Operator I Operator II Operator I Operator II
3 1.017415 1.01677 1.01685 1.000634 1.000556
4 1.004243 1.00378 1.00379 1.000461 1.000451
5 2.125686 2.12462 2.12593 1.000502 0.999885
6 2.117538 2.15718 2.15798 1.000166 .999795
Mean values of correction factors 1.000441 1.000172

Table 6 gives the observed and corrected ratios for the two sets of data. 207Pb/206Pb is corrected by 1/2 of the measured bias, and 204Pb/206Pb is corrected by the inverse of the measured bias. Table 7 gives the final absolute values for all of the ratios along with the overall limits of error and uncertainty components. The precision was essentially the same for both sets of data, so the final values are straight averages of the two sets. Because of instrumental uncertainties, such as dead zone and recorder nonlinearity, it is assumed that no ratio can be measured to better than 0.00002; so this figure is used as an error value whenever the statistically determined 95 percent confidence limit is smaller than 0.00002.

Table 6.

Observed and corrected isotopic ratios for the standard samples

Sample Operator Observed ratios Corrected ratios
204Pb/206Pb 207Pb/206Pb 208Pb/206Pb 204Pb/206Pb 207Pb/206Pb 208Pb/206Pb
Common I 0.059067 0.91437 2.1669 0.059041 0.91457 2.1678
SRM 981 II .059053 .91465 2.1680 .059043 .91472 2.1684
Equal-Atom I 0.027223 0.46679 0.99964 0.027211 0.46689 1.00009
SRM 982 II .027232 .46721 1.00007 .027227 .46725 1.00024
Radiogenic I 0.0003723 0.071178 0.013611 0.0003721 0.071194 0.013617
SRM 983 II .0003693 .071202 .013619 .0003692 .071208 .013621

Table 7.

Absolute isotopic ratios for the three standard samples

204Pb/206Pb 207Pb/206Pb 208Pb/206Pb
Common Lead (SRM 981) 0.059042 0.91464 2.1681
Overall limit of errora ±0.000037 ±0.00033 ±0.0008
Uncertainty Components: 95% confidence limits on ratio determination (minimum = 0.00002) ±0.000020 ±0.00007 ±0.0002
Bounds due to possible systematic error in chemical analyses ±0.000005 ±0.00007 ±0.0002
Bounds due to possible systematic error in correction factor (including errors in separated isotopes) ±0.000012 ±0.00019 ±0.0004
Equal-Atom Lead (SRM 982) 0.027219 0.46707 1.00016
Overall limit of error ±0.000027 ±0.00020 ±0.00036
Uncertainty Components: 95% confidence limits on ratio determination (minimum = 0.00002) ±0.000020 ±0.00006 ± 0.00007
Bounds due to possible systematic error in chemical analyses ±0.000002 ±0.00004 ±0.00008
Bounds due to possible systematic error in correction factor (including errors in separated isotopes) ±0.000005 ±0.00010 ±0.00021
Radiogenic Lead (SRM 983) 0.000371 0.071201 0.013619
Overall limit of error ±0.000020 ±0.000040 ±0.000024
Uncertainty Components: 95% confidence limits on ratio determination (minimum =0.00002) ±0.000020 ±0.000020 ±0.000020
Bounds due to possible systematic error in chemical analyses ±0.000000 ±0.000006 ±0.000001
Bounds due to possible systematic error in correction factor (including errors in separated isotopes) ±0.000000 ±0.000014 ±0.000003
a

The overall limit of error is the sum of the 95 percent confidence limits for the ratio determinations and the terms covering effects of known sources of possible systematic error.

Table 8 gives the atomic percents for each of the isotopes in each standard sample, and the atomic weights (12C = 12) of each standard. Nuclidic masses were taken from Mattauch et al. [13].

Table 8.

Atom percents and atomic weights for the three standard samples

Overall limit of errora Uncertainty components
Mass spectrometric analytical error Possible systematic error in chemical analysis Possible systematic error in composition of separated isotopes
Common Lead (SRM 981) Atomic weight 207.2152 ±0.00015 ±0.00004 ±0.00003 ±0.00008
Atom percent:
204Pb 1 4245 ±0.0012 ±0.0005 ±0.0002 ±0.0005
206Pb 24 1447 ±0.0057 ±0.0014 ±0.0012 ±0.0031
207Pb 22 0827 ±0.0027 ±0.0019 ±0.0002 ±0.0006
208Pb 52 3481 ±0.0086 ±0.0028 ±0.0016 ±0.0042
Equal-Atom Lead (SRM 982) Atomic weight 206.9429 ±0.00014 ±0.00003 ±0.00003 ±0.00008
Atom percent:
204Pb 1 0912 ±0.0012 ±0.0008 ±0.0001 ±0.0003
206Pb 40.0890 ±0.0072 ±0.0015 ±0.0016 ±0.0041
207Pb 18 7244 ±0.0023 ±0.0022 ±0.0000 ±0.0001
208Pb 40 0954 ±0 0077 ±0.0019 ±0.0016 ±0.0042
Radiogenic Lead (SRM 983) Atomic weight 206.0646.. ±0.00009 ±0.00006 ±0.00001 ±0.00002
Atom percent:
204Pb 0 0342 ±0.0020 ±0.0020 ±0.0000 ±0.0000
206Pb 92 1497 ±0.0041 ±0.0029 ±0.0003 ±0.0009
207Pb 6 5611 ±0.0025 ±0.0017 ±0.0002 ±0.0006
208Pb 1 2550 ±0.0022 ±0.0018 ±0.0001 ±0.0003
Nuclidic Masses: 203.973044, 205.974468, 206.975903, 207.976650
a

The overall limit of error is the sum of the 95 percent confidence limits for the ratio determinations and the terms covering effects of known sources of possible systematic error.

We are indebted to Mrs. Martha Darr for the quantitative spectrochemical analyses of the lead isotope samples and to Hsien H. Ku for the statistical analysis of the experimental data.

4. Appendix

A catalog listing all of the NBS Standard Reference Materials, including Isotopic Standards, may be obtained from the Superintendent of Documents, U.S. Government Printing Office, Washington, D.C. 20402. The serial number of the catalog is: NBS Miscellaneous Publication 260. The price is 45 cents.

Aliquots of the lead isotope standards described in this paper may be purchased from the NBS in the following manner. Orders should be addressed to the Office of Standard Reference Materials, National Bureau of Standards, Washington, D.C. 20234. The order should stipulate: 1 g each of NBS SRM Nos. 981, 982, and 983 (lead isotope reference standards). The price is $100 per set and they are only sold as a set.

The isotopic compositions of the uranium-isotope standards are given in the table below. These materials are sold individually in 1-g units of U3O8. Prices range from $37.50/unit for U005 to $54.50/unit for U930.

NBS best estimate from pooled data of isotopic composition of uranium standards (atom %)

SRM No. U234 U235 U236 U238 235/238
U005 0.0022 0.4896 0.0047 99.5035 0.004920
U010 .0054 1.0038 .0068 98.9840 .010141
U015 .0085 1.5322 .0164 98.4429 .015564
U020 .0125 2.0383 .0165 97.9327 .020813
U030 .0190 3.0459 .0204 96.9147 .031429
U050 .0279 5.0089 .0480 94.9152 .05277
NBS certified values (atom %)
U100 0.0676 10.190 0.0379 89.704 0.11360
U150 .0993 15.307 .0660 84.528 .18109
U200 .1246 20.013 .2116 79.651 .25126
U350 .2498 35.190 .1673 64.393 .5465
U500 .5181 49.696 .0755 49.711 .9997
U750 .5923 75.357 .2499 23.801 3.166
U800 .6563 80.279 .2445 18.820 4.266
U850 .6437 85.137 .3704 13.848 6.148
U900 .7777 90.196 .3327 8.693 10.375
U930 1.0812 93.336 .2027 5.380 17.349

Footnotes

1

Figures in brackets indicate the literature references at the end of this paper.

5. References

  • [1].Shields W. R., Garner E. L., and Dibeler V. H., J. Res. NBS 66A (Phys. and Chem.), No. 1, 1 (1962). [Google Scholar]
  • [2].Shields W. R., Murphy T. J., Garner E. L., and Dibeler V. H., J. Am. Chem. Soc. 84, 1519 (1962). [Google Scholar]
  • [3].Shields W. R., Murphy T. J., and Garner E. L.. J. Res. NBS 68A (Phys. and Chem.), No. 6, 589 (1964). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [4].Gatanzaro E. J., Murphy T. J., Garner E. L., and Shields W. R., J. Res. NBS 68A (Phys. and Chem.), No. 6, 593 (1964). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [5].Shields W. R., Murphy T. J., Catanzaro E. J., and Garner E. L., J. Res. NBS 70A (Phys. and Chem.), No. 2, 193 (1966). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [6].Catanzaro E. J., Murphy T. J., Garner E. L., and Shields W. R., J. Res. NBS 70A (Phys. and Chem.), No. 6, 453 (1966). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [7].Russell R. D. and Farquhar R. M., Lead Isotopes in Geology (Interscience, New York, 1960). [Google Scholar]
  • [8].Catanzaro E. J., Earth and Plan. Sci. Letters 3, No. 4, 343, (1968). [Google Scholar]
  • [9].Shields W. R., editor, NBS Tech. Note 426 (1967). [Google Scholar]
  • [10].Catanzaro E. J., J. Geophys. Res. 72, No. 4, 1325 (1967). [Google Scholar]
  • [11].Marienko G. and Taylor J. K., J. Res. NBS 67A (Phys. and Chem.), No. 5, 453 (1963). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [12].Murthy B. K. N., Pro. of Indian Acad. Sci. 31A, 160 (1950). [Google Scholar]
  • [13].Mattauch J. H. E., Thiele W., and Wapstra A. H., Nuclear Physics 67, 1 (1965). [Google Scholar]

Articles from Journal of Research of the National Bureau of Standards. Section A, Physics and Chemistry are provided here courtesy of National Institute of Standards and Technology

RESOURCES