Interleukin (IL)‐6 and IL‐8 were measured in 101 serum samples collected from eight intensive‐care unit patients using a polystyrene‐based stick enzyme‐linked immunosorbent assay (STICKELISA) system. This system consisted of an immobilized‐antibody ELISA stick and a noncontact spectrophotometer. Cytokine concentration was detected by two ways: first, rapidly and semi‐quantitatively by naked‐eye observation of the color change and second, quantitatively using the spectrophotometer for accurate concentration determination. The spectrophotometric assay enabled the quantitation of as little as 100 pg/mL cytokine and took only 45 min to complete. There was a good agreement between the STICKELISA observations and data ob‐tained using a plate ELISA system. The agreement between STICKELISA naked‐eye observation and plate ELISA determination was 94 and 85% for IL‐6 and IL‐8, respectively. The correlation coefficients between the STICKELISA spectrophotometric determination and plate ELISA determination were 0.88 and 0.91 for IL‐6 and IL‐8, respectively, in a 0.1–5 ng/mL cytokine concentration range. These results demonstrate that the STICKELISA system is a simple, rapid, and quantitative method for bedside cytokine measurement in critical‐care settings. J. Clin. Lab. Anal. 23:40–44, 2009. © 2009 Wiley‐Liss, Inc.
Keywords: cytokine, STICKELISA, critical care, rapid detection, colorimetric
REFERENCES
- 1. Tracy KJ. Physiology and immunology of the cholinergic antiinflammatory pathway. J Clin Invest 2007;117:289–296. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2. Carlet J. Rapid diagnostic method in the detection of sepsis. Infect Dis Clin North Am 1999;13:483–494. [DOI] [PubMed] [Google Scholar]
- 3. Oda S, Hirasawa H, Shiga H, Nakanishi K, Matsuda K, Nakamura M. Sequential measurement of IL‐6 blood levels in patients with systemic inflammatory response syndrome (SIRS) sepsis. Cytokine 2005;21:169–175. [DOI] [PubMed] [Google Scholar]
- 4. Kurt AN, Aygun AD, Godekmerdan A, Kurt A, Dogan Y, Yilmaz E. Serum IL‐1beta, IL‐6, IL‐8 and TNF‐alpha levels in early diagnosis and management of neonatal sepsis. Mediators Inflamm 2007(ID31397):1–5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5. Carrera E, García T, Céspedes A, et al. Immunostick colorimetric ELISA assay for the identification of smoked salmon, trout and bream. J Sci Food Agric 1997;74:547–550. [Google Scholar]
- 6. Rossi CL, Tsang VC, Pilcher JB. Rapid, low‐technology field‐ and laboratory‐applicable enzyme‐linked immunosorbent assays for immunodiagnosis of Schistosoma mansoni. J Clin Microbiol 1991;29:1836–1841. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.CIE Supplement No.2 to Publication (CIE No.15 E‐1.3.1). Colorimetry: Uniform Colour Spaces, Colour Difference Equations and Metric Colour Terms. Paris: Central de la CIE, 1978. [Google Scholar]