Abstract
Background: It has been reported that the increase of QT dispersion (QTD) that occurs due to increased inhomogeneity of the ventricular repolarization because of transient ischemia obtained by standard 12‐lead electrocardiogram (ECG), the changes during exercise, and the differences between exercise and rest increase the accuracy of exercise test in the diagnosis of coronary artery disease (CAD).
Hypothesis: This study was designed to investigate the value of QTD parameters, which are reported to increase the diagnostic accuracy of exercise test in women.
Methods: Ninety‐seven women who had undergone coronary angiography and exercise test were evaluated for diagnosis of chest pain. QT dispersion was calculated using the measurements of the highest and lowest values of QT interval obtained by ECG during peak exercise. The QTc using Bazett's equation, and the QTD ratio (QTDR) using QT/RR were calculated, and QTcD and QTD ratios were obtained. The difference between QTcD and QTDR was determined by extracting the rest values from the exercise values.
Results: The groups with normal coronaries (n = 48), single‐vessel CAD (n= 24), and multivessel CAD (n= 25) were compared. The obtained QTD parameters at peak exercise and their differences between exercise and rest were found to be significantly increased in patients with CAD (p<0.001).
Furthermore, these parameters were found to be higher in the patients with multivessel CAD than in those with single‐vessel disease (p < 0.05). With the parameters QTcD > 60 ms and QTDR > 10%, greater sensitivity and specificity were obtained compared with ST‐segment depression. The highest diagnostic accuracy was obtained with the QTD parameters calculated from the differences between rest and exercise values. The diagnostic accuracy of the difference of QTcD > 15 ms and the difference of QTDR > 5% was relatively higher than the other parameters (sensitivity, specificity, and negative and positive predictor values are 84,88,84, 87% and 84, 96, 85, 95%, respectively).
Conclusion: The use of QTD parameters as variables of ECG, which is easily obtainable in the evaluation of exercise ECG in women, increases the diagnostic accuracy of the exercise test. In addition, the evaluation of QTD variables may provide information about the incidence of CAD.
Keywords: electrocardiography, exercise, QT dispersion, women
Full Text
The Full Text of this article is available as a PDF (55.9 KB).
References
- 1. Alexander KP, Shaw LJ, Delong ER, Mark DB, Peterson ED: Value of exercise treadmill testing in women. J Am Coll Cardiol 1998; 32: 1657–1664 [DOI] [PubMed] [Google Scholar]
- 2. Manca C, Dei Cas L, Bernardini B, Barilli AL, Tsialtas D, Vasini P, Visioli O: Comparative evaluation of exercise ST response in healthy males and females. Cardiology 1984; 71: 341–347 [DOI] [PubMed] [Google Scholar]
- 3. Shaw LV, Miller D, Romies JC, Kargl D, Younis LT, Chaitman BR: Gender differences in the noninvasive evaluation and management of patients with suspected coronary artery disease. Ann Intern Med 1994; 120: 559–566 [DOI] [PubMed] [Google Scholar]
- 4. Morise AP, Diamond GA: Comparison of the sensitivity and specificity of exercise electrocardiography in biased and unbiased populations of men and women. Am Heart J 1995; 130: 741–747 [DOI] [PubMed] [Google Scholar]
- 5. Gibbons RJ, Balady GJ, Beasley JW, Bricker JT, Duvernoy WF, Froelicher VF, Mark DB, Marwick TH, McCallister BD, Thompson PD, Winters WL Jr, Yanowitz FG, Ritchie JL, Cheitlin MD, Eagle KA, Gardner TJ, Garson A Jr, Lewis RP, O'Rourke RA, Ryan TJ: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Exercise Testing). J Am Coll Cardiol 1997; 30: 260–315 [DOI] [PubMed] [Google Scholar]
- 6. Han J, Moc GK: Nonuniform recovery of excitability in ventricular muscle. Circ Res 1964; 14: 342–344 [DOI] [PubMed] [Google Scholar]
- 7. Pye M, Quinn AC, Cobbe SM: QT interval dispersion: A non‐invasive marker of susceptibility to arrhythmia in patients with sustained ventricular arrhythmias? Br Heart J 1994; 71: 511–514 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8. Sporton SC, Taggart P, Sutton PM, Walker JM, Hardman SM: Acute ischemia: A dynamic influence on QT dispersion. Lancet 1997; 349: 306–309 [DOI] [PubMed] [Google Scholar]
- 9. Stierle U, Giannitsis E, Sheikhzadeh A, Kruger D, Schmucker G, Mitusch R, Potrazt J: Relation between Qt dispersion and the extent of myocardial ischemia in patients with three‐vessel coronary artery disease. Am J Cardiol 1998; 81: 564–568 [DOI] [PubMed] [Google Scholar]
- 10. Moreno FL, Villanueva T, Karagounis LA, Anderson JL: Reduction in QT interval dispersion by successful thrombolytic therapy in acute myocardial infarction. Circulation 1994; 90: 94–100 [DOI] [PubMed] [Google Scholar]
- 11. Stoletniy LN, Pai RG: Value of QT dispersion in the interpretation of exercise stress test in women. Circulation 1997; 96: 904–910 [DOI] [PubMed] [Google Scholar]
- 12. Koide Y, Yotsukura M, Yoshino H, Ishikawa K: Value of QT dispersion in the interpretation of treadmill exercise electrocardiograms of patients without exercise‐induced chest pain or ST‐segment depression. Am J Cardiol 2000; 85: 1094–1099 [DOI] [PubMed] [Google Scholar]
- 13. Higham PD, Furniss SS, Campbell RWF: QT dispersion and components of the QT interval in ischemia and infarction. Br Heart J 1995; 73: 32–38 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14. Okin PM, Kligfeld P: Gender‐specific criteria and performance of the exercise electrocardiogram. Circulation 1995; 92: 1209–1216 [DOI] [PubMed] [Google Scholar]
- 15. Chaitman BR: Exercise stress testing In Heart Disease, 6th Edition (Eds. Braunwald E, Zipes DP, Libby P.), p. 129–159. Philadelphia: W. B. Saunders Co., 2001. [Google Scholar]
- 16. Bazett HC: An analysis of the time‐relations of electrocardiograms. Heart 1920; 7: 353–370 [Google Scholar]
- 17. Bland MJ, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 8: 307–310 [PubMed] [Google Scholar]
- 18. Zhao D, Freeman DH, deFilippi CR: A meta‐analysis of gender differences in exercise testing. Circulation 1995; 94:I–497 [Google Scholar]
- 19. Guiteras P, Chaitman BR, Waters DD, Bourassa MG, Scholl JM, Ferguson RJ, Wagniart P: Diagnostic accuracy of exercise ECG lead systems in clinical subsets of women. Circulation 1982; 65: 1465–1474 [DOI] [PubMed] [Google Scholar]
- 20. Arab D, Valeti V, Schüneman HJ, López‐Candales A: Usefulness of the QTc interval in predicting myocardial ischemia in patients undergoing exercise stress testing. Am J Cardiol 2000; 85: 764–766 [DOI] [PubMed] [Google Scholar]
- 21. Mark DB, Hlatky MA, Harrell FE, Lee KL, Califf RM, Pryor DB: Exercise treadmill score for predicting prognosis in coronary artery disease. Ann Int Med 1987; 106: 793–800 [DOI] [PubMed] [Google Scholar]
- 22. Bonow RO, Vitale DF, Bacharach SL, Frederick TM, Kent KM, Green MV: Asynchronous left ventricular regional function and impaired global diastolic filling in patients with coronary artery disease: Reversal after coronary angioplasty. Circulation 1985; 71: 297–307 [DOI] [PubMed] [Google Scholar]
- 23. Kors JA, van Herpen G: Measurement error as a source of QT dispersion: A computerized analysis. Heart 1998; 80: 453–458 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24. Teragawa H, Hirao H, Muraoka Y, Yamagata T, Matsuura H, Kajiyama G: Relation between QT dispersion and adenosine triphosphate stress thallium–201 single‐photon emission computed tomographic imaging for detecting myocardial ischemia and scar. Am J Cardiol 1999; 83: 1152–1156 [DOI] [PubMed] [Google Scholar]
- 25. Koide Y, Yotsukura M, Tajino K, Yoshino H, Ishikawa K: Use of QT dispersion measured on treadmill exercise electrocardiograms for detecting restenosis after percutaneous transluminal coronary angioplasty. Clin Cardiol 1999; 22: 639–648 [DOI] [PMC free article] [PubMed] [Google Scholar]