Abstract
Background: Spontaneous echo contrast (SEC) is a phenomenon that is commonly seen in areas of blood stasis. It is a slowly moving, cloud‐like swirling pattern of “smoke” or increased echogenicity recorded on echocardiography. SEC is commonly seen in the left atrium of patients with mitral stenosis or atrial fibrillation. The prescence of SEC has been shown to be a marker of increased thromboembolic risk.
Hypothesis: By using transesophageal echocardiography during percutaneous balloon mitral valvotomy (PBMV), the study investigated the relationship between SEC and varying left atrial appendage (LAA) blood flow velocity in the human heart.
Methods: Thirty—five patients with rheumatic mitral stenosis underwent percutaneous balloon mitral valvotomy with intraoperative transesophageal echocardiography monitoring. We alternatively measured LAA velocities and observed the left atrium for various grades of SEC (0 = none to 4 = severe) before and after each balloon inflation.
Results: Left atrial appendage maximal ejection velocity was reduced from 35 ± 14 to 6 ± 2 mm/s at peak balloon inflation and increased to 40 ± 16 mm/s after balloon deflation. In comparison with the values before balloon inflation and after balloon deflation, LAA velocities were significantly lower (p < 0.001). New or increased SEC grade was observed during 54 of 61 (88%) inflations and unchanged in 7 (12%) inflations at peak balloon inflation. Spontaneous echo contrast became lower in grade after 55 balloon deflations (90%), completely disappeared after 18 deflations (30%), and remained unchanged after 6 deflations (10%). The mean time to achieve maximal SEC grade (2.5 ± 1.2 s) coincided with the mean time to trough LAA velocities (2.3 ±1.1 s) after balloon inflation. Upon deflation, the mean time to lowest SEC grade (2.9 ± 1.8 s) coincided with mean time to achieve maximal LAA velocities (2.7 ± 1.6s).
Conclusion: During balloon inflation, the severity of SEC was enhanced with corresponding reduction in LAA flow velocity. Upon balloon deflation, SEC lightens or disappears with increase in LAA flow velocity.
Keywords: spontaneous echo contrast, left atrial appendage velocity, percutaneous balloon mitral valvotomy, thromboembolism, mitral stenosis
Full Text
The Full Text of this article is available as a PDF (727.3 KB).
References
- 1. Erbel R, Stern H, Ehrenthal W, Schreiner G, Treese N, Krumer G, Thelen M, Schweizer P: Detection of spontaneous echocardiogra‐phic contrast within the left atrium by transesophageal echocardiography: Spontaneous echocardiographic contrast. Clin Cardiol 1986; 9: 245–252 [DOI] [PubMed] [Google Scholar]
- 2. Chia BL, Choo MH, Yan PC, Ee BK, Lee C‐N, Shears JH: Intra‐atrial smoke‐like echoes and thrombi formation. Chest 1989; 95: 912–914 [DOI] [PubMed] [Google Scholar]
- 3. Daniel WG, Nellessen U, Schroder E, Nonnast DB, Bednarski P, Lichtlen PR: Left atrial spontaneous echo contrast in mitral valve disease: An indicator for an increased thromboembolic risk. J Am Coll Cardiol 1988; 11: 1204–1211 [DOI] [PubMed] [Google Scholar]
- 4. Black IW, Hopkins AP, Lee LC, Walsh WF: Left atrial spontaneous echo contrast: A clinical and echocardiographic analysis. J Am Coll Cardiol 1991; 18: 398–404 [DOI] [PubMed] [Google Scholar]
- 5. Zabalgoitia M, Halperin JL, Pearce LA, Blackshear JL, Asinger RW, Hart RG: Transesophageal echocardiographic correlates of clinical risk of thromboembolism in nonvalvular atrial fibrillation. Stroke Prevention in Atrial Fibrillation III Investigators. J Am Coll Cardiol 1998; 31: 1622–1626 [DOI] [PubMed] [Google Scholar]
- 6. Kasliwal RR, Mittal S, Kanojia A, Singh RP, Prakash O, Bhatia ML, Trehan N: A study of spontaneous echo contrast in patients with rheumatic mitral stenosis and normal sinus rhythm: An Indian perspective. Br Heart J 1995; 74: 296–299 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7. Rittoo D, Sutherland GR, Currie P, Starkey IR, Shaw TR: A prospective study of left atrial spontaneous echo contrast and thrombus in 100 consecutive patients referred for balloon dilation of the mitral valve. J Am Soc Echocardiogr 1994; 7: 516–527 [DOI] [PubMed] [Google Scholar]
- 8. Sigel B, Coelho JCU, Spigo DG, Flanigan DP, Schuler JJ, Kasprisin DO, Nytrus LM, Capek V: Ultrasonography of blood during stasis and coagulation. Invest Radiol 1981; 16: 71–76 [DOI] [PubMed] [Google Scholar]
- 9. Mikell FL, Asinger RW, Elsperger J, Anderson WR, Hodges M: Regional stasis of blood in the dysfunctional left ventricle: Echo cardiographic detection and differentiation from early thrombosis. Circulation 1982; 66: 755–763 [DOI] [PubMed] [Google Scholar]
- 10. Machi J, Sigel B, Beitler JC, Coelho JCU, Justin JR.: Relation of in vivo blood flow to ultrasound echogenicity. J Clin Ultrasound 1983; 11: 3–5 [DOI] [PubMed] [Google Scholar]
- 11. Sigel B, Machi J, Beitler JC, Ramos JR, Justin JR, Feinberg H: Ultrasonic detection of red cell aggregation immediately preceding blood clotting. Invest Radiol 1984; 19: 458–461 [DOI] [PubMed] [Google Scholar]
- 12. Merino A, Hauptman P, Badimon L, Badimon JJ, Cohen M, Fuster V, Goldman M: Echocardiography “smoke” is produced by an interaction of erythrocytes and plasma proteins modulated by shear forces. J Am Coll Cardiol 1992; 20: 1661–1668 [DOI] [PubMed] [Google Scholar]
- 13. Fatkin D, Loupas T, Low J, Feneley M: Inhibition of red cell aggregation prevents spontaneous echocardiographic contrast formation in human blood. Circulation 1997; 96: 889–896 [DOI] [PubMed] [Google Scholar]
- 14. Feigenbaum H: Hemodynamic information derived from echocardiography. Echocardiography, Fifth Edition, (Ed. Bussy RK.), p. 194–195. Philadelphia: Lea & Febiger, 1994. [Google Scholar]
- 15. Fatkin D, Kelly R, Feneley M: Relations between left atrial appendage blood flow velocity, spontaneous echocardiographic contrast and thromboembolic risk in vivo. J Am Coll Cardiol 1994; 23: 961–969 [DOI] [PubMed] [Google Scholar]
- 16. Inoue K, Owaki T, Nakamura T, Kitamura F, Miyamoto N: Clinical application of transverse mitral commissurotomy by a new balloon catheter. J Thorac Cardiovasc Surg 1984; 87: 394–402 [PubMed] [Google Scholar]
- 17. Porte JM, Cormier B, lung B, Dadez E, Starkman C, Nallet O, Michel PL, Acar J, Vahanian A: Early assessment by transesophageal echocardiography of left atrial appendage function after percutaneous mitral commissurotomy. Am J Cardiol 1996; 77: 72–76 [DOI] [PubMed] [Google Scholar]
- 18. Karatasakis GT, Gotsis AC, Cokkinos DV: Influence of mitral regurgitation on left atrial thrombus and spontaneous echocardiographic contrast in patients with rheumatic mitral valve disease. Am J Cardiol 1995; 76: 279–281 [DOI] [PubMed] [Google Scholar]
- 19. Drobninski G, Montalescot G, Evans J, Thomas D: Systemic embolization as a complication of percutaneous mitral valvuloplasty. Cathet Cardiovasc Diagn 1992; 25: 327–335 [DOI] [PubMed] [Google Scholar]
- 20. Li YH, Hwang JJ, Lin JL, Tseng YZ, Lien WP: Importance of left atrial appendage function as a risk factor for systemic thromboembolism in patients with rheumatic mitral valve disease. Am J Cardiol 1996; 78: 844–847 [DOI] [PubMed] [Google Scholar]
- 21. Palacios IF: Percutaneous mitral valvotomy for patients with mitral stenosis. CurrOpin Cardiol 1994; 9: 164–175 [DOI] [PubMed] [Google Scholar]
- 22. Gencbay M, Turan F, Degertekin M, Yaymaci B, Dindar I: Contrast echoes detected during percutaneous mitral balloon commissurotomy with Inoue balloons and their relation to cerebral microembolic signals. Angiology 1998; 49: 909–914 [DOI] [PubMed] [Google Scholar]
- 23. Fatkin D, Roy P, Sindone A, Feneley M: Rapid onset and dissipation of left atrial spontaneous echo contrast during percutaneous balloon mitral valvotomy. Am Heart J 1998; 135: 609–613 [DOI] [PubMed] [Google Scholar]