New developments in ultrasound systems for contrast echocardiography

Sanjiv Kaul 1,2
PMCID: PMC6656200  PMID: 9383599

Abstract

Contrast echocardiography (CE) has evolved significantly in the past decade. Contrast agents and the hardware and software used to detect them and display optimal images have developed in tandem. Not only are hardware and contrast agents available that allow left ventricular cavity enhancement, but recent research points to the usefulness of CE for the evaluation of myocardial perfusion in the cardiac catheterization laboratory and operating room. Advances in ultrasound technology, such as transient harmonic imaging and integrated backscatter, coupled with the development of newer contrast agents that contain smaller, more stable microbubbles capable of transpulmonary passage for intravenous injection, promise a vast increase in the applications of CE in clinical practice.

Keywords: ultrasound, contrast echocardiography, contrast agents, myocardial perfusion, harmonic imaging, backscatter, microbubbles, transpulmonary, Doppler, gray scale

Full Text

The Full Text of this article is available as a PDF (458.9 KB).

References

  • 1. Sheil MLK, Kaul S, Spotnitz WD: Myocardial contrast echocardiography: Development, applications, and future directions, Acad Radiol 1996; 3: 260–275 [DOI] [PubMed] [Google Scholar]
  • 2. Rovai D, Lombardi M, Distante A, L'Abbate A: Myocardial perfusion by contrast echocardiography: From off‐line processing to radio frequency analysis. Circulation 1991; 83 (suppl III): III–97–III–103 [PubMed] [Google Scholar]
  • 3. Powsner SM, Keller MW, Saniie J, Feinstein SB: Quantitation of echo‐contrast effects. Am J Physiol Imag 1986; 1: 124–128 [PubMed] [Google Scholar]
  • 4. Marini C, Ghelardini G, Picano E, Rovai D, Lombardi M, Trivella MG, Distante A, L'Abbate A: Effects of coronary blood flow on myocardial grey level amplitude in two dimensional echocardiography: An experimental study. Cardiovasc Res 1993; 27: 279–283 [DOI] [PubMed] [Google Scholar]
  • 5. Kaul S: Myocardial contrast echocardiography. Curr Opin Cardiol 1997. (in press) [DOI] [PubMed]
  • 6. Sponheim N, Myhrum M: An in vitro study on the influence of limited frequency resolution on contrast agent‐enhanced Doppler signals. Ultrasonics 1996; 34: 599–601 [DOI] [PubMed] [Google Scholar]
  • 7. Melany ML, Grant EG: Clinical experience with sonographic contrast agents. Semin US CT MRI 1997; 18: 3–12 [DOI] [PubMed] [Google Scholar]
  • 8. Firschke C, Lindner JR, Wei K, Goodman NC, Skyba DM, Kaul S: Myocardial perfusion imaging in the setting of coronary artery stenosis and acute myocardial infarction using venous injection of a second‐generation echocardiographic contrast agent. Circulation 1997; 96: 959–967 [PubMed] [Google Scholar]
  • 9. Skyba DM, Jayaweera AR, Goodman NC, Ismail S, Camarano GP, Kaul S: Quantification of myocardial perfusion with myocardial contrast echocardiography from left atrial injection of contrast: Implications for venous injection. Circulation 1994; 90: 1513–1521 [DOI] [PubMed] [Google Scholar]
  • 10. Rovai D, Lombardi M, Mazzarisi A, Landini L, Taddei L, Distante A, Benassi A, L'Abbate A: Flow quantification by radio frequency analysis of contrast echocardiography. Int J Card Imaging 1993; 9: 7–19 [DOI] [PubMed] [Google Scholar]
  • 11. Gottlieb S, Ernst A, Meltzer RS: Effect of pressure on echocardiographic videodensity from sonicated albumin: An in vitro model. J Ultrasound Med 1995; 14: 109–116 [DOI] [PubMed] [Google Scholar]
  • 12. Vuille C, Nidorf M, Morrissey RL, Newell JB, Weyman AE, Picard MH: Effect of static pressure on the disappearance rate of specific echocardiographic contrast agents. J Am Soc Echocardiogr 1994; 7: 347–354 [DOI] [PubMed] [Google Scholar]
  • 13. Padial LR, Chen MH, Vuille C, Guerrero JL, Weyman AE, Picard MH: Pulsatile pressure affects the disappearance of echocardiographic contrast agents. J Am Soc Echocardiogr 1995; 8: 285–292 [DOI] [PubMed] [Google Scholar]
  • 14. Brayman A, Azadniv M, Miller MW, Meltzer RS: Effect of static pressure on acoustic transmittance of Albunex® microbubble suspensions. J Acoust Soc Am 1996; 99: 2403–2408 [DOI] [PubMed] [Google Scholar]
  • 15. Wei K, Skyba DM, Firschke C, Jayaweera AR, Lindner JR, Kaul S: Interactions between microbubbles and ultrasound: In vitro and in vivo observation. J Am Coll Cardiol 1997; 29: 1081–1088 [DOI] [PubMed] [Google Scholar]
  • 16. Porter TR, Xie F, Li S, D'Sa A, Rafter P: Increased ultrasound contrast and decreased microbubble destruction rates with triggered ultrasound imaging. J Am Soc Echocardiogr 1996; 9: 599–605 [DOI] [PubMed] [Google Scholar]
  • 17. Wray RA, Quiñones MA, Zoghbi WA, Cheirif J: Relation of mean pixel intensity to concentration of sonicated albumin microspheres: Effects of ultrasound system settings. Clin Cardiol 1991; 14 (suppl V): V–23–V–28 [DOI] [PubMed] [Google Scholar]
  • 18. Schwarz KQ, Bezante GP, Chen X, Phillips D, Schlief R: Hemodynamic effects of microbubble echo contrast. J Am Soc Echocardiogr 1996; 9: 795–804 [DOI] [PubMed] [Google Scholar]
  • 19. Marmion M, Deutsch E: Tracers and contrast agents in cardiovascular imaging: Present and future. J Nucl Med 1996; 40: 121–131 [PubMed] [Google Scholar]
  • 20. Firschke C, Lindner JR, Goodman NC, Skyba DM, Wei K, Kaul S: Myocardial contrast echocardiography in acute myocardial infarction using aortic root injections of microbubbles in conjunction with harmonic imaging: Potential applications in the cardiac catheterization laboratory. J Am Coll Cardiol 1997; 29: 207–216 [DOI] [PubMed] [Google Scholar]
  • 21. Schrope B, Newhouse VL, Uhlendorf V: Simulated capillary blood flow measurement using a non‐linear ultrasonic contrast agent. Ultrason Imag 1992; 14: 134–158 [DOI] [PubMed] [Google Scholar]
  • 22. Burns PN, Powers JE, Simpson DH, Uhlendorf V, Fritzsche T: Harmonic imaging: Principles and preliminary results. Clin Radiol 1996; 51 (suppl 1): 50–55 [PubMed] [Google Scholar]
  • 23. de Jong N: Higher harmonics of vibrating gas‐filled microspheres In Acoustic Properties of Ultrasound Contrast Agents (Ed. de Jong N.), p. 61–78. Worerden: Zuidam and Zonen bv, 1993. [Google Scholar]
  • 24. Firschke C, Köberl B, von Bibra H, Horcher J, Schömg A: Combined use of contrast enhanced 2‐dimensional and color Doppler echocardiography for improved left ventricular echocardial border delineation using Levovist, a new venous echocardiographic contrast agent, Int J Card Imaging 1997; 13: 137–144 [DOI] [PubMed] [Google Scholar]
  • 25. Forsberg F, Goldberg BB, Liu JB, Merton DA, Rawool NM: On the feasibility of real‐time, in vivo harmonic imaging with proteinaceous microspheres. J Ultrasound Med 1996; 15: 853–860 [DOI] [PubMed] [Google Scholar]
  • 26. Porter TR, Xie F: Transient myocardial contrast after initial exposure to diagnostic ultrasound pressures with minute doses of intravenously injected microbubbles: Demonstration and potential mechanisms. Circulation 1995; 92: 2391–2395 [DOI] [PubMed] [Google Scholar]
  • 27. Kaul S, Senior R, Dittrich H, Raval U, Khattar R, Lahiri A: Detection of coronary artery disease using myocardial contrast echocardiography: Comparison with 99m Tc‐sestamibi singlephoton emission computed tomography. Circulation 1997; 96: 785–792 [PubMed] [Google Scholar]
  • 28. Villanueva FS, Glasheen WP, Sklenar J, Kaul S: Assessment of risk area during coronary occlusion and infarct size after reperfusion with myocardial contrast echocardiography using left and right atrial injections of contrast. Circulation 1993; 88: 596–604 [DOI] [PubMed] [Google Scholar]
  • 29. Grauer SE, Walker K, Porter T, Xie F, Ge J, Powers J, Giraud GD, Sahn DJ: Quantitative analysis of harmonic myocardial perfusion signal imaging with transvenous echocontrast agents: Animal studies. Presented at the American Heart Association, 68th Scientific Sessions, Medical Research, November 13–16, 1995, Anaheim. Calif.
  • 30. Porter TR, Li S, Kricsfeld D, Armbruster RW: Detection of myocardial perfusion in multiple echocardiographic windows with one intravenous injection of microbubbles using transient response second harmonic imaging. J Am Coll Cardiol 1997; 29: 791–799 [DOI] [PubMed] [Google Scholar]
  • 31. Lindner JR, Dent JM, Moon S, Jayaweera AR, Kaul S: Enhancement of left ventricular cavity opacification by harmonic imaging after venous injection of Albunex® . Am J Cardiol 1997; 79: 1657–1662 [DOI] [PubMed] [Google Scholar]
  • 32. Goens MB, Martin GR: Acoustic quantification: A new tool for diagnostic echocardiography. Curr Opin Cardiol 1996; 11: 52–60 [DOI] [PubMed] [Google Scholar]
  • 33. Holland MR, Hall CS, Lewis SH, Handley SM, Finch‐Johnston AE, D'Sa AP, Perez JE, Miller JG: Comparison of integrated backscatter values obtained with acoustic densitometry with values derived from spectral analysis of digitized signals from a clinical imaging system. J Am Soc Echocardiogr 1997; 10: 511–517 [DOI] [PubMed] [Google Scholar]
  • 34. Belohlavek M, Foley DA, Gerber TC, Kinter TM, Greenleaf JF, Seward JB: Three‐and four‐dimensional cardiovascular ultrasound imaging: A new era for echocardiography. Mayo Clin Proc 1993; 68: 221–240 [DOI] [PubMed] [Google Scholar]
  • 35. de Jong N, Ten Cate FJ: New ultrasound contrast agents and technological innovations. Ultrasonics 1996; 34: 587–590 [DOI] [PubMed] [Google Scholar]
  • 36. Desai R, Buckey JC, Pearce JA: A real‐time multi‐processor 3‐D echocardiographic reconstruction system. Biomed Sci Instrum 1993; 29: 377–383 [PubMed] [Google Scholar]
  • 37. Ge J, Erbel R: Novel techniques of coronary artery imaging. Curr Opin Cardiol 1995; 10: 626–633 [DOI] [PubMed] [Google Scholar]
  • 38. Marx GR: Advances in cardiac imaging in congenital heart disease. Curr Opin Pediatr 1995; 7: 580–586 [DOI] [PubMed] [Google Scholar]
  • 39. Linka AZ, Ates G, Wei K, Firoozan S, Skyba DM, Kaul S: Three‐dimensional myocardial contrast echocardiography: Validation of in‐vivo risk and infarct volumes,. Am Coll Cardiol 1997. (in press) [DOI] [PubMed]
  • 40. Jayaweera AR, Kaul S: Quantification of myocardial blood flow with contrast echocardiography. Am J Card Imag 1993; 7: 317–335 [PubMed] [Google Scholar]
  • 41. Villarraga HR, Foley DA, Mulvagh SL: Contrast echocardiography 1996: A review. Tex Heart Inst J 1996; 23: 90–97 [PMC free article] [PubMed] [Google Scholar]
  • 42. Powers J: Contrast Agents in Echocardiography, p. 5 Bothell, Wash.: Advanced Technology Laboratories, 1996. [Google Scholar]

Articles from Clinical Cardiology are provided here courtesy of Wiley

RESOURCES