Skip to main content
Springer logoLink to Springer
. 2019 Jul 3;23(7):633–637. doi: 10.1007/s10151-019-02022-w

A prospective pilot study on MRI visibility of iron oxide-impregnated polyvinylidene fluoride mesh after ventral rectopexy

K E Laitakari 1,3,, J K Mäkelä-Kaikkonen 1,3, E Pääkkö 2, P Ohtonen 1,3, T T Rautio 1,3
PMCID: PMC6692291  PMID: 31270653

Abstract

Background

Magnetic resonance imaging (MRI) provides excellent information about pelvic anatomy after ventral rectopexy, but the position of the conventional mesh is not seen constantly. Iron oxide-impregnated polyvinylidene fluoride (PVDF) meshes are proven to have MRI visibility in hernia or vaginal reconstructive surgery. This prospective pilot study was designed to assess the visualization, position, and shape of the magnetic resonance (MR)–visible synthetic pelvic mesh used in minimally invasive ventral rectopexy.

Methods

Eight patients with pelvic organ prolapse were recruited for laparoscopic (LVMR) or robotic-assisted ventral mesh rectopexy (RVMR) with a synthetic MR–visible PVDF mesh. A follow-up visit was scheduled at 3 months after surgery. MR imaging was performed to evaluate the position and dimensions of the mesh and anatomical result. The visibility of the mesh in each sequence was assessed subjectively.

Results

The visibility of the mesh was best on T1-weighted flash images. The mesh was also well visualized on T2-weighted sagittal images. T2-weighted images, in general, provided best visualization of the surrounding anatomical structures and enabled assessment of the mesh fixation.

Conclusions

T2 sagittal and T1-weighted flash images provide the best information about the position and integrity of the iron oxide-impregnated PVDF mesh after LVMR or RVMR with a short examination time.

Keywords: Rectal prolapse, Ventral rectopexy, Mesh, Magnetic resonance imaging (MRI), MR contrasting implant, Iron oxide-impregnated polyvinylidene fluoride

Introduction

Laparoscopic ventral mesh rectopexy (LVMR) introduced by Andre D’Hoore has become commonly used treatment for rectal prolapse [14]. This minimally invasive procedure, also feasible with a robotic approach [5], offers the advantages of decreased risk of damaging autonomic nerves, recurrence, and new-onset post-operative symptoms. Anatomical and functional changes in the pelvic floor after anterior rectopexy have been described [68], but there are no studies that have investigated the position and dimensions of the mesh.

The risk of mesh-related complications like erosions, mesh infection, dyspareunia or fistula formation is quite low [810]. However, post-operative de-novo symptoms such as urinary retention, fecal incontinence, constipation or pelvic/abdominal pain are not so infrequent [4, 8, 9, 11]. The overall recurrence rate of rectal prolapse after laparoscopic or robotic-assisted ventral mesh rectopexy (RVMR) is up to 15.4% [46, 8, 11]. MR-contrasting implants have been suggested to be helpful in diagnosing post-operative problems non-invasively.

The aim of this prospective pilot study was to assess the visualization, position, and dimensions of the MR–visible synthetic mesh after LVRM or RVMR. The primary outcomes were the quantificational characterization of mesh position and anatomical changes.

Materials and methods

Study population and data collection

From February to April 2018, eight unselected consecutive patients with pelvic organ prolapse were recruited for laparoscopic or RVMR with a synthetic MR–visible polyvinylidene fluoride (PVDF) mesh in Oulu University Hospital, Finland. Written informed consent was obtained from all patients. All data about patient characteristics and post-operative recovery were collected prospectively. The study was approved by the local Ethics Committee.

Surgical technique

The surgical procedures were primarily carried out as described by D’Hoore and Penninckx [2] with minor modifications. The da Vinci Surgical System (Intuitive Surgical Inc., Sunnyvale, CA, USA) with five trocar placements and side docking was used to perform RVMR. The mesh was positioned as far distally as possible and sutured to the levator muscles and on the anterior rectal wall with multiple interrupted seromuscular non-absorbable sutures (2-0 Ethibond, Ethicon Endosurgery). In laparoscopic procedures, only four to five sutures were used to fix the mesh on the proximal rectal wall, and the distal part of the mesh was fixed with glue. For the sacral promontory fixation, spiral attachments (Pro-Tack TM Fixation Device, Medtronic) were used. The peritoneum was closed over the mesh with continuous suture with absorbable V-Loc™ 90 (Medtronic). Peri-operative care was conducted according to the enhanced recovery after surgery protocol.

Mesh information

MR–visible polyvinylidene fluoride (PVDF) 4 × 23 cm meshes (Dynamesh® IPOM, FEG Textiltechnik, Aachen, Germany) containing paramagnetic iron oxide microparticles (Fe3O4 with iron load of 10 mg/g polymer) were used. This macroporous (> 1 mm) mesh consists of 88% visceral-sided PDVF monofilament and 12% parietal-sided polypropylene monofilament.

Follow-up

A follow-up visit was scheduled at 3 months after surgery. Patients were evaluated for their pelvic clinical status and the functional results assessed with questionnaires reflecting quality of life and possible post-operative symptoms. MR imaging was performed for radiological evaluation of position and dimensions of the mesh and anatomical result.

Magnetic resonance imaging

Magnetic resonance imaging (MRI) was performed by a 3 T magnet (Siemens, Vida, Erlangen, Germany). The patients were asked to empty the bladder before imaging. No other patient preparation was used. Patients were lying supine in the magnet. A body matrix surface coil was used in addition to the posterior spine coil.

T2-weighted sagittal, coronal, and transverse images were obtained (TR 3720–6100, TE 81–90, sagittal and coronal FOV 230, transverse FOV 200, 3 mm slice, 0.6 mm gap, sagittal and coronal matrix 256 × 320, transverse matrix 544 × 640). Breath-hold transverse T1-weighted vibe Dixon (TR 4, TE 1.3 and 2.5, FOV 309 × 380, 3 mm slice, 195 × 320 matrix) and T1-weighted (TR 129, TE 2.5, FOV 333 × 380, 3 mm slice, 210 × 320 matrix) flash images were also obtained. Total time of the examination was 30–35 min.

The visibility of the mesh in each sequence was assessed subjectively. Scores from 1 to 4 were used. Score 1 was given to image series if the mesh was visible in all slices. In score 2, 3, and 4, the visibility was ≥ 3/4, ≥ 1/2 or < 1/2 of the slices.

The position of the lower insertion point according to anorectal junction was assessed, as well as the insertion point to the levator muscle on each side. The length of insertion to the anterior rectal wall was measured. The width of the mesh was measured at the lower insertion point, at the highest insertion point in the rectum, and at the higher insertion point in the promontorium. Also, the narrowest part of the mesh was measured, as well as its distance from the highest rectal insertion point.

Results

Eight female patients were included in this analysis, and their baseline clinical characteristics and used surgical technique are given in Table 1. All operations were primary except one robotic re-rectopexy for patient D (Table 1) with recurrent enterocele after previous ventral rectopexy. Mean operative time was 131 min (SD 44.4) and blood loss was 68 ml (SD 138.5). One laparoscopic operation was converted to open, and patient G (Table 1) had mild post-operative acute myocardial infarction. There were no peri-operative or any post-operative surgical complications. Mean hospital stay was 1.5 days (SD 0.76).

Table 1.

Baseline characteristics and peri-operative outcome

Patient Age (years) ASA BMI (kg/m2) Diagnosis Indication Surgical technique Operation time (min) Blood loss (ml)
A 63 3 24 Enterocele Incontinence RVMR 86 20
B 56 2 22 Enterocele ODS RVMR 90 400
C 88 3 22 Prolapse Prolapse RVMR 121 0
D 53 2 23 Enterocele Incontinence RVMRa 174 0
E 77 3 27 Prolapse Prolapse RVMR 214 100
F 49 2 24 Enterocele Incontinence LVMR 148 0
G 77 3 25 Invagination Incontinence LVMRb 118 20
H 41 2 22 Invagination Incontinence LVMR 106 0

ASA American Society of Anesthesiologists, BMI body mass index, ODS obstructed defecation syndrome, RVMR robotic ventral rectopexy, LVMR laparoscopic ventral rectopexy

aRe-rectopexy

bConversion

All patients had a 3-month follow-up with MRI imaging. The results of mesh position and dimensions are summarized in Table 2. The anatomical correction of the pelvic floor was excellent in all cases and there were no significant differences in any proportions of the meshes. Fixation of the meshes to the levator muscles and to promontorium was also seen (Fig. 1b; Table 2).

Table 2.

Pelvic floor area measurements on MRI

Patient Parameter
Anorectal junctiona Right levator muscleb Left levator musclec Anterior rectal walld Lower insertion pointe Highest insertion pointf Narrowest partg Distance from the insertion pointh Promontoriumi
A 0 Yes Yes 93 36 28 16 6 22
B 0 Yes Yes 86 31 23 15 5 20
C 0 Yes Yes 87 40 33 17 20 26
D 0 Yes No 105 40 45 19 15 34
E 20 Yes Yes 43 34 22 10 42 22
F 0 Yes Yes 79 45 29 28 14 26
G 0 Yes Yes 96 38 30 15 32 38
H 7 Yes Yes 58 43 29 11 26 33

MRI magnetic resonance imaging

aDistance of the lower insertion point from the anorectal junction (mm)

bThe position of the insertion point to the right levator muscle

cThe position of the insertion point to the left levator muscle

dLength of insertion to the anterior rectal wall (mm)

eWidth of the mesh at the lower insertion point (mm)

fWidth of the mesh at the highest insertion point in the rectum (mm)

gNarrowest part of the mesh (mm)

hThe distance of the narrowest part of the mesh from the highest rectal insertion point (mm)

iWidth of the mesh at the higher insertion point in the promontorium (mm)

Fig. 1.

Fig. 1

a The mesh is visualized in its full length on T2-weighted sagittal image. On T1-weighted flash images, the mesh is also well visualized close to the lower insertion point (b) and at the higher insertion on the rectal wall (c)

The visibility of the mesh was best on T1-weighted flash images (scoring 1 in all cases) as shown in Table 3. The mesh was also well visualized on T2-weighted sagittal images (scoring 1 in six cases, 3 in one case, and 4 in one case with severe movement artifacts). T2-weighted images, in general, provided best visualization of the surrounding anatomical structures (Fig. 1).

Table 3.

The visibility of the mesh in MRI sequences

Patient MRI sequence
T2 sagittal T2 transverse T2 coronal T1 flash Dixon in phase Dixon out of phase
A 1 4 4 1 2 4
B 3 4 4 1 2 4
C 1 3 4 1 1 4
D 4 4 4 1 2 4
E 1 3 3 1 1 4
F 1 4 4 1 2 4
G 1 2 3 1 2 4
H 1 3 3 1 2 4

1, mesh was visible in all slices; 2, visibility was ≥ 3/4 of the slices; 3, visibility was ≥ 1/2 of the slices; 4, visibility was < 1/2 of the slices

MRI magnetic resonance imaging

Discussion

This pilot study was designed to find the best way to visualize the iron oxide-impregnated PVDF meshes implanted for rectal prolapse. Our results showed that position and dimensions of this new mesh are seen sufficiently to make measuring using post-operative MRI. This would be useful in cases of post-operative mesh-related complications and recurrent symptoms; particularly, when planning reoperation to check if the mesh has gotten detached from the pelvic floor or promontory attachments.

There are few previous results showing the feasibility of iron oxide-impregnated PVDF meshes in hernia and vaginal reconstructive surgery [1215]. However, this is the first study to demonstrate how the MR–visible synthetic mesh is seen after LVMR or RVMR in post-operative MRI. Therefore, it is impossible to compare our results to any previous data. We hope that other study groups will get interested in doing further research on iron oxide-impregnated PVDF meshes.

If the position and integrity of the mesh are in question, T2 sagittal and T1-weighted flash images would provide sufficient information with a short examination time. However, if there are other post-operative concerns, such as infection, a wider selection of sequences should be used together with intravenous contrast agent. Acquired information helps the design of future studies comparing different ventral rectopexy techniques, and especially mesh fixation alternatives.

Conclusions

T2 sagittal and T1-weighted flash images provide the best information about the position and integrity of the iron oxide-impregnated PVDF mesh after LVMR or RVMR with a short examination time.

Acknowledgements

Open access funding provided by University of Oulu including Oulu University Hospital.

Author contributions

KL: acquisition, analysis and interpretation of data, writing the article. JKM: conception and design of the study, acquisition, analysis and interpretation of data. EP: design of the study, analysis and interpretation of data, writing the article, critical revision. PO: design of the study, analysis and interpretation of data, writing the article, critical revision. TTR: conception and design of the study, acquisition, analysis and interpretation of data, writing the article.

Funding

State research funding.

Compliance with ethical standards

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval

The study has been approved by the Ethical Committtee of the Oulu University Hospital.

Informed consent

Written informed consent was obtained from all patients.

Footnotes

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.D’Hoore A, Cadoni R, Penninckx F. Long-term outcome of laparoscopic ventral rectopexy for total rectal prolapse. Br J Surg. 2004;91:1500–1505. doi: 10.1002/bjs.4779. [DOI] [PubMed] [Google Scholar]
  • 2.D’Hoore A, Penninckx F. Laparoscopic ventral recto(colpo)pexy for rectal prolapse: surgical technique and outcome for 109 patients. Surg Endosc. 2006;20:1919–1923. doi: 10.1007/s00464-005-0485-y. [DOI] [PubMed] [Google Scholar]
  • 3.Faucheron JL, Trilling B, Girard E, Sage PY, Barbois S, Reche F. Anterior rectopexy for full-thickness rectal prolapse. Technical and functional results. World J Gastroenterol. 2015;21:5049–5055. doi: 10.3748/wjg.v21.i16.5049. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Van Iersel JJ, Paulides TJ, Verheijen PM, Lumley JW, Broeders IA, Consten EC. Current status of laparoscopic and robotic ventral mesh rectopexy for external and internal rectal prolapse. World J Gastroenterol. 2016;22:4977–4987. doi: 10.3748/wjg.v22.i21.4977. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Van Iersel JJ, Formijne Jonkers HA, Paulides TJC, Verheijen PM, Draaisma WA, Consten ECJ, Broeders IAMJ. Robot-assisted ventral mesh rectopexy for rectal prolapse: a 5-year experience at a tertiary referral center. Dis Colon Rectum. 2017;60:1215–1223. doi: 10.1097/DCR.0000000000000895. [DOI] [PubMed] [Google Scholar]
  • 6.Mäkelä-Kaikkonen J, Rautio T, Kairaluoma M, Carpelan-Holmström M, Kössi J, Rautio A, Ohtonen P, Mäkelä J. Does ventral rectopexy improve pelvic floor function in the long term? Dis Colon Rectum. 2018;61:230–238. doi: 10.1097/DCR.0000000000000974. [DOI] [PubMed] [Google Scholar]
  • 7.Tsunoda A, Takahashi T, Hayashi K, Yagi Y, Kusanagi H. Laparoscopic ventral rectopexy in patients with fecal incontinence associated with rectoanal intussusception: prospective evaluation of clinical, physiological and morphological changes. Tech Coloproctol. 2018;22:425–431. doi: 10.1007/s10151-018-1811-4. [DOI] [PubMed] [Google Scholar]
  • 8.Consten EC, van Iersel JJ, Verheijen PM, Broeders IA, Wolthuis AM, D’Hoore A. Long-term outcome after laparoscopic ventral mesh rectopexy: an observational study of 919 consecutive patients. Ann Surg. 2015;262:742–747. doi: 10.1097/SLA.0000000000001401. [DOI] [PubMed] [Google Scholar]
  • 9.Evans C, Stevenson AR, Sileri P, Mercer-Jones MA, Dixon AR, Cunningham C, Jones OM, Lindsey I. A multicenter collaboration to assess the safety of laparoscopic ventral rectopexy. Dis Colon Rectum. 2015;58:799–807. doi: 10.1097/DCR.0000000000000402. [DOI] [PubMed] [Google Scholar]
  • 10.Smart NJ, Pathak S, Boorman P, Daniels IR. Synthetic or biological mesh use in laparoscopic ventral mesh rectopexy–a systematic review. Colorectal Dis. 2013;15:650–654. doi: 10.1111/codi.12219. [DOI] [PubMed] [Google Scholar]
  • 11.McLean R, Kipling M, Musgrave E, Mercer-Jones M. Short- and long-term clinical and patient-reported outcomes following laparoscopic ventral mesh rectopexy using biological mesh for pelvic organ prolapse: a prospective cohort study of 224 consecutive patients. Colorectal Dis. 2018;20:424–436. doi: 10.1111/codi.13996. [DOI] [PubMed] [Google Scholar]
  • 12.Sindhwani N, Callewaert G, Deprest T, Housmans S, Van Beckevoort D, Deprest J. Short term post-operative morphing of sacrocolpopexy mesh measured by magnetic resonance imaging. J Mech Behav Biomed Mater. 2018;80:269–276. doi: 10.1016/j.jmbbm.2018.02.012. [DOI] [PubMed] [Google Scholar]
  • 13.Chen L, Lenz F, Alt CD, Sohn C, De Lancey JO, Brocker KA. MRI visible Fe3O4 polypropylene mesh: 3D reconstruction of spatial relation to bony pelvis and neurovascular structures. Int Urogynecol J. 2017;28:1131–1138. doi: 10.1007/s00192-017-3263-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Joukhadar R, Meyberg-Solomayer G, Hamza A, Radosa J, Bader W, Barski D, Ismaeel F, Schneider G, Solomayer E, Baum S. A novel operative procedure for pelvic organ prolapse utilizing a MRI-visible mesh implant: safety and outcome of modified laparoscopic bilateral sacropexy. Biomed Res Int. 2015;2015:860784. doi: 10.1155/2015/860784. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Muysoms F, Beckers R, Kyle-Leinhase I. Prospective cohort study on mesh shrinkage measured with MRI after laparoscopic ventral hernia repair with an intraperitoneal iron oxide-loaded PVDF mesh. Surg Endosc. 2018;32:2822–2830. doi: 10.1007/s00464-017-5987-x. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Techniques in Coloproctology are provided here courtesy of Springer

RESOURCES