Abstract
IN BRIEF The advantage of the insulin-and-glucagon artificial pancreas is based on the rapid effect of subcutaneous glucagon delivery in preventing hypoglycemia compared to suspension of insulin delivery. In short-term studies, the dual-hormone artificial pancreas reduced daytime hypoglycemia, especially during exercise, compared to the insulin-alone artificial pancreas, but the insulin-alone system seemed sufficient in eliminating nocturnal hypoglycemia. The comparative benefits of the single- and dual-hormone systems for improving A1C and preventing severe hypoglycemia remain unknown.
The benefit of tight glycemic control for reducing microvascular complications and all-cause mortality in type 1 diabetes is hindered by the increased risk of hypoglycemia. Fear of hypoglycemia often leads to permissive hyperglycemia, which leads to suboptimal A1C levels among individuals with type 1 diabetes (1).
The artificial pancreas is an automated insulin delivery system that combines a glucose sensor, an insulin pump, and an insulin dosing algorithm. The artificial pancreas improves time in the glycemic target range, reduces hypoglycemia, and improves quality of life in people with type 1 diabetes compared to conventional insulin pump therapy (2–4). However, clinically significant hypoglycemia and hyperglycemia still exist with the artificial pancreas (5,6). The dual-hormone artificial pancreas, delivering insulin and glucagon, has been proposed as an alternative to the insulin-alone artificial pancreas (7–10). In this article, we present the basics of the dual-hormone artificial pancreas and discuss its benefits and drawbacks compared to the insulin-alone artificial pancreas.
Rationale for the Dual-Hormone System: A Pharmacokinetics View
In healthy individuals, glucose levels are tightly controlled by the complex glucose-responsive activities of the pancreatic hormones insulin (glucose lowering) and glucagon (glucose raising) released into the portal vein, as well as cephalic insulin release, paracrine signalling between β-cells and α-cells, and exercise-induced glucagon secretion. In progressive type 1 diabetes, impaired glucagon response and gradual dysregulation of pancreatic α-cells and β-cells lead to elevated risk of hypoglycemia in the presence of exogenous insulin (11–14). Because subcutaneous glucagon is rapidly absorbed, prevention of hypoglycemia is more effective with administration of subcutaneous glucagon than with suspension of subcutaneous insulin (15). Rapid-acting subcutaneous insulin formulations have an onset of action of 10–15 minutes, time to maximal glucose excursion of 40–60 minutes, and duration of action of 4–6 hours (16). Thus, for some period after insulin suspension, previously delivered insulin via the subcutaneous route will still appear in the plasma. The relatively slow pharmacokinetic profile of subcutaneous insulin remains a limitation for avoidance of hypoglycemia during rapidly decreasing glucose levels. However, subcutaneous glucagon acts rapidly, with onset of 5 minutes and a time to peak plasma glucagon level of approximately 15–20 minutes (17–20). A dose-dependent, rapid, two- to threefold rise in glucose levels can be achieved with small doses of subcutaneous glucagon (18–20).
In the dual-hormone artificial pancreas, glucagon can be used in different approaches (21). In one approach, insulin optimizes glycemic control and mini-boluses of glucagon are added to prevent residual hypoglycemia, without a concomitant increase in insulin delivery. An alternative method provides more aggressive insulin delivery to target a lower blood glucose concentration and balances the increased risk of hypoglycemia with intermittent glucagon doses. A third option combines the two previous options, with use of glucagon to prevent hypoglycemia and to allow increased insulin delivery to reduce mean glucose levels.
The amount of daily glucagon dose depends on the specific approach used; algorithms aiming to reduce hypoglycemia use the lowest total daily glucagon dose, whereas those targeting a lower mean glucose use the most glucagon, and a combination of the two approaches leads to glucagon dosing in between these two extremes. The total daily dose of glucagon in tested dual-hormone systems has been observed to be between 0.145 and 0.82 mg/day (21). These amounts of delivery resulted in plasma glucagon levels mostly in the physiological range of 50–150 pg/mL, although occasionally induced transient hyperglucagonemia (9,17).
It is important to note that circulating plasma insulin levels affect glucagon action. In the presence of high insulin levels, the efficacy of glucagon is impaired, whereas at low or moderate insulin levels, glucagon effectively raises glucose levels in a dose-responsive manner (22–24). Thus, the addition of glucagon to a dual-hormone artificial pancreas does not allow liberal insulin dosing, nor does it completely eliminate the risk of hypoglycemia. For example, in a study of 11 individuals with type 1 diabetes using a dual-hormone system with an aggressive insulin dosing algorithm, five participants experienced hypoglycemia due to accumulation of excess insulin, despite delivery of large amounts of glucagon (17). When the experiments were repeated with a less aggressive insulin dosing algorithm, hypoglycemia was eliminated.
Efficacy of Dual-Hormone Systems
Eight published studies have directly compared single- and dual-hormone artificial pancreas systems (8,9,25–30) (Table 1). In each of these studies, the dual-hormone system used a glucagon-dosing algorithm aimed at reducing hypoglycemia, as opposed to one that allows more aggressive insulin delivery.
TABLE 1.
Summary of Results from Eight Randomized Crossover Controlled Studies With Direct Comparison of Dual- and Single-Hormone Artificial Pancreas Systems
| Year (Ref.) | Setting and Duration of Intervention | n | Participant Characteristics, mean (SD) | Study Arms | Insulin Delivery | Glucagon, mg | Time in Hypoglycemia (<70 or <72 mg/dL), % | Hypoglycemia Events¥, No. per participant | Mean Glucose, mg/dL | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| A1C, mmol/mol;% | Age, years | Median (IQR) or mean (SD) | P | Mean (SD) | P | |||||||
| 2010 (8) | Inpatient, 9 hours or 28 hours | 13 adults | 60 (3); 7.6 (0.3) | 37 (4) | Dual-hormone | 54 U/day | 0.62/day | 1.0 (0.4)* | 0.04 | 1.1/day* | 145 (14) | NS |
| Single-hormone | 48 U/day | — | 2.8 (0.7)* | 2.3/day* | 135 (16) | |||||||
| 2015 (9) | Inpatient, 24 hours | 30 (20 adults, 10 adolescents) | 60 (11); 7.7 (1.0) | 33 (18) | Dual-hormone | 43 U/day 9 U/night | 0.18/day 0.052/night | 1.5 (0–3.5) | 0.018 | 0.3/day 0/night | 144 (25) | 0.14 |
| Single-hormone | 44 U/day 9 U/night | — | 3.1 (0.6–8.7) | 0.43/day 0/night | 139 (25) | |||||||
| 2015 (27) | Outpatient (camp), overnight (three nights) | 33 children | 67 (8); 8.3 (0.8) | 13 (3) | Dual-hormone | 0.9 U/hour | 0.04/night | 0.0 (0–2.4) | 0.032 | 0.0/night | 139 (31) | 0.066 |
| Single-hormone | 0.9 U/hour | — | 3.1 (0–6.9) | 0.04/night | 146 (31) | |||||||
| 2016 (29) | Outpatient, overnight (two nights) | 28 (21 adults, 7 adolescents) | 58 (11); 7.5 (1.0) | 33 (17) | Dual-hormone | 1 U/hour | 0.07/night | 1.0 (0–8.0) | 0.34 | 0.05/night | 111 (29) | 0.32 |
| Single-hormone | 1 U/hour | — | 5.0 (0–13.0) | 0.11/night | 111 (31) | |||||||
| 2016 (26) | Inpatient, 90 minutes† (exercise study) | 17 adults | 64 (10); 8.0 (0.9) | 37 (14) | Dual-hormone | 0.4 U/hour | 0.11/90 minutes | 0.0 (0–0) | <0.001 | 0.09/90 minutes | — | — |
| Single-hormone | 0.3U/hour | — | 11.0 (0–46.7) | 0.46/90 minutes | — | |||||||
| 2017 (28) | Outpatient, day and night 60 hours) | 23 adults | 58 (9); 7.5 (0.8) | 41 (15) | Dual-hormone | 0.8 U/hour | 0.58/60 hours | 3.6 (1.4–4.9) | 0.072 | 0.26/60 hours 0.04/night | 142 (29) | 0.98 |
| Single-hormone | 0.8 U/hour | — | 3.9 (2.2–7.0) | 0.61/60 hours 0.11/night | 142 (22) | |||||||
| 2018 (30) | Inpatient, overnight | 18 adults with hypoglycemia unawareness and 17 with hypoglycemia awareness | 60 (8); 7.7 (0.7) | 46 (18) | Dual-hormone | 1.0 U/hour | 0.023/night | 0.0 (0–0.1) | 0.349 | 0.06/night | 137 (33) | 0.92 |
| Single-hormone | 1.0 U/hour | — | 0.0 (0–1.6) | 0.11/night | 136 (27) | |||||||
| 2018 (25) | Outpatient, four days | 20 adults | 58 (9.8); 7.5 (0.9) | 34 (5) | Dual-hormone | 44 U/day | 0.51/day | 1.3 (1.0) | <0.001 | — | 155 (16) | 0.062 |
| Single-hormone | 43 U/day | — | 2.8 (1.7) | — | 148 (12) | |||||||
Hypoglycemia events were defined as <54–59 mg/dL, except if indicated otherwise.
Treatment of hypoglycemia was administered at glucose levels <3.9 mmol/L.
60 minutes exercise and 30 minutes recovery. IQR, interquartile range; U, units.
Reduction of Hypoglycemia
Most, but not all, studies reported less overall hypoglycemia with the dual-hormone artificial pancreas than with the insulin-alone artificial pancreas (8,9,25,28). One outpatient study in 23 adults over 60 hours reported six hypoglycemic events (<54 mg/dL) with the dual-hormone system compared with 14 events with the single-hormone system (28). Another outpatient study in 20 adults over 4 days reported lower time spent in hypoglycemia (<70 mg/dL) with the dual-hormone artificial pancreas (1.3%) compared to the insulin-alone artificial pancreas (2.8%, P <0.0001) (25).
Prevention of Hypoglycemia During and After Exercise
Aerobic physical activity leads to rapid decline in glucose levels due to accelerated glucose uptake, increased insulin sensitivity, and faster insulin absorption (31). Attempting to prevent hypoglycemia by suspending insulin delivery is not always effective because the glucose-lowering effect of physical activity is usually faster than the glucose-raising effect of insulin suspension (32,33). In this context, the rapid onset of glucagon delivery may be beneficial for preventing hypoglycemia during exercise. One study compared single- and dual-hormone artificial pancreas systems during 60 minutes of moderate continuous and interval aerobic exercise sessions and showed less time in hypoglycemia (<72 mg/dL) with the dual-hormone system (time in hypoglycemia median 0 vs. 11%, P = 0.0001) (26). It is worth noting that glucagon administration in the dual-hormone system increased the plasma glucagon concentration by a factor of 2.5 in comparison to the single-hormone artificial pancreas, which is comparable to the 1.4- to 3-fold increase observed in healthy individuals performing exercise at 40–70% VO2peak (34,35). Another study over 4 days that included three moderate-intensity aerobic exercise sessions showed less time spent in hypoglycemia (<70 mg/dL) during the exercise period with the dual-hormone artificial pancreas (3.4%) compared to the single-hormone artificial pancreas (8.3%, P = 0.0009) (25).
Late-onset post-exercise hypoglycemia affects individuals with type 1 diabetes through the alterations in insulin sensitivity and glucose uptake for up to 11 hours after exercise (26–38). Two studies compared the single- and dual-hormone artificial pancreas on nights after daytime exercise and observed no difference between the two systems (9,29). Both systems nearly eliminated post-exercise nocturnal hypoglycemia (<54 mg/dL); the sufficiency of the insulin-alone system can be explained by the slow decline in glucose levels during the post-exercise period.
Prevention of Nocturnal Hypoglycemia
Several studies in adults and pediatric patients showed no difference in nocturnal hypoglycemia with the dual-hormone artificial pancreas compared to the single-hormone artificial pancreas (9,25,28,29), including in patients with hypoglycemia unawareness and documented previous nocturnal hypoglycemia (30). This observation is not related to the inefficiency of glucagon delivery overnight, but rather to the sufficiency of the single-hormone system in counteracting slow variations in nocturnal glucose levels. However, in diabetes camp settings with unusually high levels of physical activity, one study in children and adolescents showed that a dual-hormone system was more effective than a single-hormone system at reducing nocturnal hypoglycemia (27).
Severe Hypoglycemia
It is currently unknown whether the dual-hormone artificial pancreas reduces the incidence of severe hypoglycemia compared to the single-hormone artificial pancreas. It is important to note that the risk of severe hypoglycemia will likely be low with the single-hormone artificial pancreas (5,6). Thus, studies assessing the additional benefits of the dual-hormone artificial pancreas in reducing severe hypoglycemia might be more desirable in high-risk populations such as those experiencing recurrent severe hypoglycemia (39).
Reduction of Mean Glucose Levels
Adding glucagon to the artificial pancreas could reduce mean glucose levels and consequently A1C by allowing more aggressive insulin delivery (21). However, long-term studies comparing the effects of single- and dual-hormone artificial pancreas on A1C levels are lacking. Moreover, short-term studies assessing dual-hormone systems versus single-hormone systems did not use glucagon to allow aggressive insulin delivery, and thus, the comparative efficacy of each system to reduce mean glucose levels is still unknown.
Glycemic Control in the Prandial Period
Using glucagon to allow more aggressive prandial boluses to reduce postprandial glucose peaks is unlikely to be an effective strategy. One study in children investigated using 60% higher prandial insulin boluses along with glucagon mini-boluses to prevent late postprandial hypoglycemia and showed no reduction in early postprandial hyperglycemia compared to usual insulin dosing (40). Instead, the system delivered glucagon 3–4 hours after the meal to prevent late postprandial hypoglycemia due to the increased prandial insulin bolus.
Positive Behavior Change and Improved Quality of Life
More than 60% of adults with type 1 diabetes are sedentary (41). Fear of hypoglycemia has been reported as a major barrier to exercise (42). Adding an extra layer of hypoglycemia protection with glucagon may promote physical activity in patients with type 1 diabetes. In one qualitative study, participants reported that the insulin-alone artificial pancreas allowed them to exercise more freely (3). It is currently unknown whether the dual-hormone artificial pancreas would bring additional benefits in patient experience, behaviors, and psychosocial outcomes related to exercise.
Practical Considerations of the Dual-Hormone Artificial Pancreas
The dual-hormone artificial pancreas will require dual-chamber pumps, which are currently in development, but they will also require two infusion sites, additional drug manipulation, and additional patient education. The need for two infusion sites and frequent sites rotation might be a particular limitation for younger, smaller patients. Moreover, current glucagon formulations are not suitable for continuous pump use (i.e., not stable in liquid form), but several alternative, stable liquid glucagon formulations are under development (43).
Common side effects reported with high-dose rescue glucagon include nausea, vomiting, and headaches, but glucagon has the potential for pleiotropic effects as it affects gastrointestinal motility, cardiac contractility, renal function, the central nervous system, and lipolysis in adipose tissue (44). The safety of long-term low doses of novel glucagon formulations is yet to be established and will be required by the U.S. Food and Drug Administration before the approval of any dual-hormone artificial pancreas system.
In animal studies, long-term glucagon exposure resulted in increased hepatic glycogen stores (45–47). In one human study in individuals with well-controlled diabetes, glycogen stores and glucagon response were maintained after repeated glucagon administration under fasting and fed conditions (48). More data are needed, but it appears unlikely that repeated small doses of glucagon will deplete glycogen stores.
Other Dual-Hormone Systems
Pramlintide is an analog of amylin, a hormone that is co-secreted with insulin in healthy individuals but is deficient in type 1 diabetes. Injecting pramlintide at mealtimes delays gastric emptying, suppresses glucagon secretion, and increases satiety (49). Recent studies assessing the addition of adding prandial pramlintide injections to an insulin-alone artificial pancreas (50–52) reported a reduction in postprandial glucose excursions (50,51). Despite its benefits, injecting pramlintide at mealtimes may be a barrier to patient acceptance and long-term compliance (53), and thus, attempts to develop stable co-formulations of insulin and pramlintide are underway (54–56). A co-formulation would deliver pramlintide during fasting as well as at mealtimes, which aligns with the natural physiology of the pancreas. A dual-hormone artificial pancreas system that delivers basal-bolus pramlintide along with insulin with a fixed ratio, mimicking a co-formulation, has been recently tested with promising preliminary results (57).
Conclusion
The glucose-raising effect of subcutaneous glucagon delivery is faster than the effect of insulin suspension in the prevention of hypoglycemia, and thus the insulin-and-glucagon artificial pancreas is more potent in preventing hypoglycemia than the insulin-alone artificial pancreas. At times when glucose levels vary slowly, such as overnight, the insulin-alone artificial pancreas seem sufficient in preventing hypoglycemia, but the dual-hormone artificial pancreas has apparent benefits during times of rapidly changing glucose levels, such as during exercise. The dual-hormone artificial pancreas should, in theory, lead to lower A1C compared to insulin-alone artificial pancreas by allowing more aggressive insulin delivery, but studies of appropriate size and duration are needed to assess this approach.
Acknowledgments
Duality of Interest
A.H. has received research support, intellectual property purchase fees, or consulting fees from AgaMatrix, Dexcom, Eli Lilly and Company, and Medtronic and has pending patents in the artificial pancreas area. No other potential conflicts of interest relevant to this article were reported.
Author Contributions
A.H. is the sole author and guarantor of this work and, as such, takes responsibility for the integrity and accuracy of the data presented.
References
- 1.Miller KM, Foster NC, Beck RW, et al.; T1D Exchange Clinic Network . Current state of type 1 diabetes treatment in the U.S.: updated data from the T1D Exchange clinic registry. Diabetes Care 2015;38:971–978 [DOI] [PubMed] [Google Scholar]
- 2.Weisman A, Bai JW, Cardinez M, Kramer CK, Perkins BA. Effect of artificial pancreas systems on glycaemic control in patients with type 1 diabetes: a systematic review and meta-analysis of outpatient randomised controlled trials. Lancet Diabetes Endocrinol 2017;5:501–512 [DOI] [PubMed] [Google Scholar]
- 3.Iturralde E, Tanenbaum ML, Hanes SJ, et al. Expectations and attitudes of individuals with type 1 diabetes after using a hybrid closed loop system. Diabetes Educ 2017;43:223–232 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Barnard KD, Wysocki T, Ully V, et al. Closing the loop in adults, children and adolescents with suboptimally controlled type 1 diabetes under free living conditions: a psychosocial substudy. J Diabetes Sci Technol 2017:11:1080–1088 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Bergenstal RM, Garg S, Weinzimer SA, et al. Safety of a hybrid closed-loop insulin delivery system in patients with type 1 diabetes. JAMA 2016;316:1407–1408 [DOI] [PubMed] [Google Scholar]
- 6.Thabit H, Tauschmann M, Allen JM, et al. Home use of an artificial beta cell in type 1 diabetes. N Engl J Med 2015;373:2129–2140 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Russell SJ, El-Khatib FH, Sinha M, et al. Outpatient glycemic control with a bionic pancreas in type 1 diabetes. N Engl J Med 2014;371:313–325 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Castle JR, Engle JM, El Youssef J, et al. Novel use of glucagon in a closed-loop system for prevention of hypoglycemia in type 1 diabetes. Diabetes Care 2010;33:1282–1287 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Haidar A, Legault L, Messier V, Mitre TM, Leroux C, Rabasa-Lhoret R. Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: an open-label randomised controlled crossover trial. Lancet Diabetes Endocrinol 2015;3:17–26 [DOI] [PubMed] [Google Scholar]
- 10.van Bon AC, Luijf YM, Koebrugge R, Koops R, Hoekstra JB, DeVries JH. Feasibility of a portable bihormonal closed-loop system to control glucose excursions at home under free-living conditions for 48 hours. Diabetes Technol Ther 2014;16:131–136 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Lee YH, Wang MY, Yu XX, Unger RH. Glucagon is the key factor in the development of diabetes. Diabetologia 2016;59:1372–1375 [DOI] [PubMed] [Google Scholar]
- 12.Unger RH, Cherrington AD. Glucagonocentric restructuring of diabetes: a pathophysiologic and therapeutic makeover. J Clin Invest 2012;122:4–12 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Orskov L, Alberti KG, Mengel A, et al. Decreased hepatic glucagon responses in type 1 (insulin-dependent) diabetes mellitus. Diabetologia 1991;34:521–526 [DOI] [PubMed] [Google Scholar]
- 14.Siafarikas A, Johnston RJ, Bulsara MK, O'Leary P, Jones TW, Davis EA. Early loss of the glucagon response to hypoglycemia in adolescents with type 1 diabetes. Diabetes Care 2012;35:1757–1762 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Haidar A, Duval C, Legault L, Rabasa-Lhoret R. Pharmacokinetics of insulin aspart and glucagon in type 1 diabetes during closed-loop operation. J Diabetes Sci Technol 2013;7:1507–1512 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Home PD. The pharmacokinetics and pharmacodynamics of rapid-acting insulin analogues and their clinical consequences. Diabetes Obes Metab 2012;14:780–788 [DOI] [PubMed] [Google Scholar]
- 17.El-Khatib FH, Russell SJ, Nathan DM, Sutherlin RG, Damiano ER. A bihormonal closed-loop artificial pancreas for type 1 diabetes. Sci Transl Med 2010;2:27ra27. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Blauw H, Wendl I, DeVries JH, Heise T, Jax T; PCDIAB Consortium . Pharmacokinetics and pharmacodynamics of various glucagon dosages at different blood glucose levels. Diabetes Obes Metab 2016;18:34–39 [DOI] [PubMed] [Google Scholar]
- 19.Hovelmann U, Bysted BV, Mouritzen U, et al. Pharmacokinetic and pharmacodynamic characteristics of dasiglucagon, a novel soluble and stable glucagon analog. Diabetes Care 2018;41:531–537 [DOI] [PubMed] [Google Scholar]
- 20.Hovelmann U, Olsen MB, Mouritzen U, Lamers D, Kronshage B, Heise T. Low doses of dasiglucagon consistently increase plasma glucose levels from hypoglycaemia and euglycaemia in people with type 1 diabetes mellitus. Diabetes Obes Metab 2019;21:601–610 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Haidar A, Smaoui MR, Legault L, Rabasa-Lhoret R. The role of glucagon in the artificial pancreas. Lancet Diabetes Endocrinol 2016;4:476–479 [DOI] [PubMed] [Google Scholar]
- 22.El Youssef J, Castle JR, Bakhtiani PA, et al. Quantification of the glycemic response to microdoses of subcutaneous glucagon at varying insulin levels. Diabetes Care 2014;37:3054–3060 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Castle JR, Engle JM, El Youssef J, Massoud RG, Ward WK. Factors influencing the effectiveness of glucagon for preventing hypoglycemia. J Diabetes Sci Technol 2010;4:1305–1310 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Russell SJ, El-Khatib FH, Nathan DM, Damiano ER. Efficacy determinants of subcutaneous microdose glucagon during closed-loop control. J Diabetes Sci Technol 2010;4:1288–1304 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Castle JR, El Youssef J, Wilson LM, et al. Randomized outpatient trial of single- and dual-hormone closed-loop systems that adapt to exercise using wearable sensors. Diabetes Care 2018;41:1471–1477 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Taleb N, Emami A, Suppere C, et al. Efficacy of single-hormone and dual-hormone artificial pancreas during continuous and interval exercise in adult patients with type 1 diabetes: randomised controlled crossover trial. Diabetologia 2016;59:2561–2571 [DOI] [PubMed] [Google Scholar]
- 27.Haidar A, Legault L, Matteau-Pelletier L, et al. Outpatient overnight glucose control with dual-hormone artificial pancreas, single-hormone artificial pancreas, or conventional insulin pump therapy in children and adolescents with type 1 diabetes: an open-label, randomised controlled trial. Lancet Diabetes Endocrinol 2015;3:595–604 [DOI] [PubMed] [Google Scholar]
- 28.Haidar A, Messier V, Legault L, Ladouceur M, Rabasa-Lhoret R. Outpatient 60-hour day-and-night glucose control with dual-hormone artificial pancreas, single-hormone artificial pancreas, or sensor-augmented pump therapy in adults with type 1 diabetes: an open-label, randomised, crossover, controlled trial. Diabetes Obes Metab 2017;19:713–720 [DOI] [PubMed] [Google Scholar]
- 29.Haidar A, Rabasa-Lhoret R, Legault L, et al. Single- and dual-hormone artificial pancreas for overnight glucose control in type 1 diabetes. J Clin Endocrinol Metab 2016;101:214–223 [DOI] [PubMed] [Google Scholar]
- 30.Abitbol A, Rabasa-Lhoret R, Messier V, et al. Overnight glucose control with dual- and single-hormone artificial pancreas in type 1 diabetes with hypoglycemia unawareness: a randomized controlled trial. Diabetes Technol Ther 2018;20:189–196 [DOI] [PubMed] [Google Scholar]
- 31.Sylow L, Kleinert M, Richter EA, Jensen TE. Exercise-stimulated glucose uptake: regulation and implications for glycaemic control. Nat Rev Endocrinol 2017;13:133–148 [DOI] [PubMed] [Google Scholar]
- 32.Elleri D, Allen JM, Kumareswaran K, et al. Closed-loop basal insulin delivery over 36 hours in adolescents with type 1 diabetes: randomized clinical trial. Diabetes Care 2013;36:838–844 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Sherr JL, Cengiz E, Palerm CC, et al. Reduced hypoglycemia and increased time in target using closed-loop insulin delivery during nights with or without antecedent afternoon exercise in type 1 diabetes. Diabetes Care 2013;36:2909–2914 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Redmon JB, Kubo SH, Robertson RP. Glucose, insulin, and glucagon levels during exercise in pancreas transplant recipients. Diabetes Care 1995;18:457–462 [DOI] [PubMed] [Google Scholar]
- 35.Galbo H, Holst JJ, Christensen NJ. Glucagon and plasma catecholamine responses to graded and prolonged exercise in man. J Appl Physiol 1975;38:70–76 [DOI] [PubMed] [Google Scholar]
- 36.MacDonald MJ. Postexercise late-onset hypoglycemia in insulin-dependent diabetic patients. Diabetes Care 1987;10:584–588 [DOI] [PubMed] [Google Scholar]
- 37.Tamborlane WV. Triple jeopardy: nocturnal hypoglycemia after exercise in the young with diabetes. J Clin Endocrinol Metab 2007;92:815–816 [DOI] [PubMed] [Google Scholar]
- 38.McMahon SK, Ferreira LD, Ratnam N, et al. Glucose requirements to maintain euglycemia after moderate-intensity afternoon exercise in adolescents with type 1 diabetes are increased in a biphasic manner. J Clin Endocrinol Metab 2007;92:963–968 [DOI] [PubMed] [Google Scholar]
- 39.Choudhary P, Rickels MR, Senior PA, et al. Evidence-informed clinical practice recommendations for treatment of type 1 diabetes complicated by problematic hypoglycemia. Diabetes Care 2015;38:1016–1029 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Heptulla RA, Rodriguez LM, Bomgaars L, Haymond MW. The role of amylin and glucagon in the dampening of glycemic excursions in children with type 1 diabetes. Diabetes 2005;54:1100–1107 [DOI] [PubMed] [Google Scholar]
- 41.Plotnikoff RC, Taylor LM, Wilson PM, et al. Factors associated with physical activity in Canadian adults with diabetes. Med Sci Sports Exerc 2006;38:1526–1534 [DOI] [PubMed] [Google Scholar]
- 42.Brazeau AS, Rabasa-Lhoret R, Strychar I, Mircescu H. Barriers to physical activity among patients with type 1 diabetes. Diabetes Care 2008;31:2108–2109 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Wilson LM, Castle JR. Stable liquid glucagon: beyond emergency hypoglycemia rescue. J Diabetes Sci Technol 2018;12:847–853 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Taleb N, Haidar A, Messier V, Gingras V, Legault L, Rabasa-Lhoret R. Glucagon in artificial pancreas systems: potential benefits and safety profile of future chronic use. Diabetes Obes Metab 2017;19:13–23 [DOI] [PubMed] [Google Scholar]
- 45.Root MA. Effect of glucagon on glycogen in rats and rabbits. Endocrinology 1956;59:340–346 [DOI] [PubMed] [Google Scholar]
- 46.Root MA. Effect of chronic administration of glucagon to rats and rabbits. Proc Soc Exp Biol Med 1954;87:108–110 [DOI] [PubMed] [Google Scholar]
- 47.Cameron JM, Melrose AG. Changes in liver, pancreatic and stomach morphology following chronic glucagon administration in guinea-pigs. Br J Exp Pathol 1962;43:384–386 [PMC free article] [PubMed] [Google Scholar]
- 48.Castle JR, El Youssef J, Bakhtiani PA, et al. Effect of repeated glucagon doses on hepatic glycogen in type 1 diabetes: implications for a bihormonal closed-loop system. Diabetes Care 2015;38:2115–2119 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Levetan C, Want LL, Weyer C, et al. Impact of pramlintide on glucose fluctuations and postprandial glucose, glucagon, and triglyceride excursions among patients with type 1 diabetes intensively treated with insulin pumps. Diabetes Care 2003;26:1–8 [DOI] [PubMed] [Google Scholar]
- 50.Weinzimer SA, Sherr JL, Cengiz E, et al. Effect of pramlintide on prandial glycemic excursions during closed-loop control in adolescents and young adults with type 1 diabetes. Diabetes Care 2012;35:1994–1999 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 51.Sherr JL, Patel NS, Michaud CI, et al. Mitigating meal-related glycemic excursions in an insulin-sparing manner during closed-loop insulin delivery: the beneficial effects of adjunctive pramlintide and liraglutide. Diabetes Care 2016;39:1127–1134 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Renukuntla VS, Ramchandani N, Trast J, Cantwell M, Heptulla RA. Role of glucagon-like peptide-1 analogue versus amylin as an adjuvant therapy in type 1 diabetes in a closed loop setting with ePID algorithm. J Diabetes Sci Technol 2014;8:1011–1017 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53.Lorenzi GM, LaRue SM, Collins SE. Effects of a patient education support program on pramlintide adherence. Clin Diabetes 2011;29:17–24 [Google Scholar]
- 54.da Silva DC, Lima L. Physico-chemical properties of co-formulated fast-acting insulin with pramlintide. Int J Pharm 2018;547:621–629 [DOI] [PubMed] [Google Scholar]
- 55.Chiquette E, Herrmann K, Maggs DG, et al. Insulin-pramlintide compositions and methods for making and using them. U.S. patent application 14/403,177 25 June 2015 [Google Scholar]
- 56.Meiffren G, Geissler A, Meyer Y, et al. BioChaperone technology enables the development of pramlintide-prandial insulin combinations [abstract]. Diabetes 2018;67(Suppl. 1):349-OR [Google Scholar]
- 57.Haidar A, Tsoukas M, Sarah T, et al. Insulin-plus-pramlintide artificial pancreas in type 1 diabetes: randomized controlled trial [abstract]. Diabetes 2018;67(Suppl. 1)210-OR [Google Scholar]
