Abstract
Purpose:
[18F]MK6240 was developed for PET imaging of tau aggregates which are implicated in Alzheimer’s disease. The goal of this work was to evaluate the kinetics of [18F]MK6240 and to investigate different strategies for in-vivo quantification of tau aggregates in humans.
Methods:
Thirty-five subjects, consisting of 18 healthy controls (CTRL), 11 subjects with mild cognitive impairment (MCI) and 6 with Alzheimer’s Disease (AD), underwent dynamic [18F]MK6240 PET scans. Arterial blood measurements were collected in 16 subjects (8 CTRLs, 6 MCIs and 2 ADs) to measure whole blood and plasma concentration time courses. Radiometabolite analysis was performed on a subset of plasma samples. Various compartmental model configurations as well as the Logan and multilinear analysis (MA1) graphical methods with arterial plasma input function were tested. Simplified reference tissue methods were investigated including Logan distribution volume ratio (DVR), multilinear reference tissue method (MRTM2) and static SUV ratio (SUVR) using the cerebellum as a reference region.
Results:
Whole blood:plasma ratio stabilized to 0.66±0.01 after 15 minutes. Percent parent in plasma (%PP) followed a single exponential and ranged from 0-10% at 90 min. [18F]MK6240 in gray matter peaked quickly (SUV>2 at ~3 minutes). The preferred compartmental model was a reversible two-tissue compartment model with the blood contribution included as a model parameter (2T4k1v). Compartmental and graphical analysis methods with arterial input functions yielded concordant results, but rapid metabolism raised challenges for blood-based quantification. MCI and AD subjects demonstrated a broad range of VT as compared to CTRL subjects. DVR from MRTM2 and Logan reference tissue methods correlated with DVR calculated indirectly from compartmental modeling, but underestimation was observed in data sets with very high binding (DVR>3). SUVR also underestimated indirect DVR from blood-based analyses in high binding regions, although a non-linear relationship was exhibited.
Conclusions:
[18F]MK6240 exhibited a wide dynamic range of uptake with binding patterns in MCI/AD subjects consistent with neurofibrillary tau deposition patterns. Linearized reference tissue methods using an estimated average tissue-to-plasma efflux constant and static SUVR agreed well with blood-based methods for most data sets, however discrepancies were noted in the highest binding cases. Exercise should therefore be cautioned in application of simplified methods to such data sets and in quantitative interpretation of corresponding outcomes.
Keywords: Positron emission tomography, [18F]MK6240, tau, pharmacokinetics, kinetic modeling
1. Introduction
Alzheimer’s disease (AD) represents the most common form of dementia by accounting for 60 to 80% of dementia cases in the world. Two key hallmarks of this disease are the abnormal accumulation of hyper-phosphorylated tau proteins and amyloid beta plaques in the brain. It has been shown that the spreading of tau neurofibrillary tangles (NFT) in the brain follows a well-defined and predictable pattern [1] as the disease progresses and, unlike amyloid beta plaques, correlates with the cognitive decline associated with the disease [2,3]. Tau pathology also plays an important role in non-AD neurodegenerative disease such as progressive supranuclear palsy cases (PSP), chronic traumatic encephalopathy (CTE) or frontotemporal dementia (FTD). Much effort has recently been put into the development of PET radiotracers for in vivo quantification of tau protein. However, even though the first generation of tau radiotracers has provided new insights into the progression of AD, they all present some limitations with respect to off-target and/or non-specific binding, which may limit their clinical utility [4–6]. Recently, Merck reported the discovery of [18F]MK6240, a novel imaging compound for detecting tau pathology [7]. Preliminary in-vitro studies in tissues from AD and non-AD human brain donors seemed to indicate high affinity and unprecedented selectivity for binding NFT and first in vivo studies in non-human primates indicated favorable pharmacokinetics for PET imaging [8]. More recently, Betthauser et al. provided a thorough investigation of [18F]MK6240 in vivo kinetics and modeling strategies in humans using reference tissue methods [9]. The main limitation of their work, however, was the lack of arterial blood sampling data for [18F]MK6240 binding quantification, which is generally considered the gold standard for quantification of physiological processes in PET imaging. Following this work, Lolith et al. as well as Pascoal et al. presented the first in-human kinetic evaluations with arterial blood sampling, each in a subset of 6 subjects [10,11]. While their results support the use of simplified semi-quantitative methods such as SUVR as a valid surrogate for NFT quantification with [18F]MK6240, Lolith et al. concluded that more studies with arterial blood sampling and kinetic modeling were needed to better understand the limitations and potential bias of such outcome.
The aim of the present work was to extend previous in-human investigations for the determination of optimal modeling strategies for in-vivo quantification of tau with [18F]MK6240. This includes a characterization of modeling methods using compartment modeling and arterial blood sampling as the reference, as well as the assessment of graphical and simplified methods.
2. Methods
2.1. Participants
As shown in Table 1, a total of 35 subjects, consisting of 18 healthy controls (CTRL), 11 subjects with mild cognitive impairment (MCI) and 6 subjects with Alzheimer’s disease (AD), were included in this work. All subjects were identified by physicians at Massachusetts General Hospital (MGH) and underwent at least one comprehensive medical and neurological evaluation using tests such as the Mini-Mental State Examination (MMSE) and/or the Clinical Dementia Rating (CDR) Scale. These subjects also underwent 11C-PiB PET scans in a separate study where PiB scores were expressed as the distribution volume ratio (DVR). DVRs were calculated in a large cortical ROI that included frontal, lateral temporal and retrosplenial cortices (FLR) using the Logan graphical method with cerebellar gray as reference tissue, as described in Johnson et al. [12]. All subjects signed an informed consent form and the study was approved by the institutional review board at MGH.
Table 1 :
Subject demographics
| Subject | Status | Sex | weight (kg) | Age (year) | FLR DVR | MMSE | CDR | Arterial blood data |
|---|---|---|---|---|---|---|---|---|
| S1 | CTRL | Male | 86.3 | 75 | 1.08 | 30 | 0 | yes |
| S2 | CTRL | Female | 74.5 | 73 | 1.09 | 30 | 0 | yes |
| S3 | CTRL | Male | 63.6 | 77 | 1.25 | 30 | 0.5 | no |
| S4 | CTRL | Male | 84.0 | 76 | 0.97 | 30 | 0.5 | yes |
| S5 | CTRL | Female | 56.8 | 45 | 1.05 | 30 | 0 | no |
| S6 | CTRL | Female | 56.3 | 75 | 1.12 | 28 | 0 | no |
| S7 | CTRL | Female | 113.5 | 78 | 0.85 | 30 | 0 | no |
| S8 | AD | Male | 70.4 | 74 | 1.62 | 24 | 1 | no |
| S9 | MCI | Male | 72.6 | 56 | 1.95 | 26 | 0.5 | yes |
| S10 | MCI | Male | 79.5 | 68 | 1.07 | 28 | 0.5 | yes |
| S11 | MCI | Female | 58.1 | 67 | 1.63 | 30 | 0.5 | no |
| S12 | MCI | Male | 85.4 | 56 | 0.96 | 27 | 0.5 | no |
| S13 | MCI | Female | 70.4 | 63 | 1.50 | 26 | 0.5 | yes |
| S14 | AD | Male | 74.0 | 84 | 1.69 | 23 | 1 | yes |
| S15 | MCI | Male | 70.4 | 87 | 1.05 | 29 | 0.5 | yes |
| S16 | CTRL | Male | 84.0 | 54 | 1.04 | 29 | 0 | yes |
| S17 | MCI | Male | 72.6 | 71 | 1.63 | 28 | 0.5 | no |
| S18 | MCI | Male | 126.7 | 75 | 1.31 | 24 | 0.5 | yes |
| S19 | AD | Male | 80.3 | 58 | 1.24 | 13 | 1 | no |
| S20 | AD | Male | 102.8 | 60 | 1.58 | 23 | 1 | yes |
| S21 | CTRL | Male | 73.2 | 36 | 1.06 | 30 | NA | yes |
| S22 | MCI | Male | 81.6 | 82 | 1.86 | 27 | 0.5 | yes |
| S23 | AD | Male | 93.0 | 58 | 1.82 | 23 | 1 | no |
| S24 | CTRL | Female | 81.6 | 76 | 1.11 | 27 | 0.5 | no |
| S25 | CTRL | Male | 102.1 | 72 | 1.04 | 27 | NA | no |
| S26 | MCI | Male | 71.7 | 83 | 1.11 | 27 | 0.5 | no |
| S27 | MCI | Male | 109.8 | 47 | 1.03 | 28 | 0.5 | no |
| S28 | CTRL | Male | 69.9 | 55 | 1.00 | 29 | 0 | yes |
| S29 | CTRL | Female | 60.8 | 85 | 1.60 | 28 | 0 | no |
| S30 | AD | Male | 52.6 | 65 | 1.66 | 15 | 1.0 | no |
| S31 | CTRL | Female | 101.6 | 58 | 0.98 | 25 | 0 | yes |
| S32 | CTRL | Male | 98.4 | 73 | 1.02 | 29 | NA | yes |
| S33 | CTRL | Female | 68.4 | 80 | 0.95 | 30 | 0 | no |
| S34 | CTRL | Female | 106.6 | 71 | 1.31 | 30 | NA | no |
| S35 | CTRL | Female | 76.7 | 83 | 2.08 | 28 | 0 | no |
2.2. Data acquisition
All enrolled subjects underwent separate PET and magnetic resonance imaging (MRI) procedures.
MR imaging:
Structural MRI was performed for anatomical reference. A 3-dimensional structural T1-weighted magnetization-prepared rapid gradient-echo (MPRAGE) was acquired using a 3T Tim Trio (Siemens Medical Systems). The MPRAGE acquisitions parameters were as follows: repetition time =2,300 ms; echo time =2.95 ms; inversion time =900 ms; flip angle = 9°; voxel size = 1.05x1.05x1.2 mm3 and matrix size = 256 x 240.
PET imaging:
[18F]MK6240 was synthesized as described in Collier et al. [13]. Eighteen participants (S1-S18) were scanned on an ECAT EXACT HR+ (CTI/Siemens). The full width at half maximum (FWHM) spatial resolutions measured at the center of the axial field of view (radial position=1cm) were reported to be 4.5 mm and 5.1 mm in transverse and axial direction respectively [14,15]. Dynamic data was measured for 135 min following bolus injection of [18F]MK6240. Subjects were allowed to take a 15 min break either at 60 min (S1 and S2) or at 90 min (all other subjects) post-tracer injection. Transmission scans using a 68Ge rod source were acquired right before acquisition of the first PET segment as well as right after the second PET segment for the purpose of attenuation correction. The remaining 17 subjects (S19-S35) were scanned on a Discovery MI (GE Healthcare) PET/CT scanner. The full width at half maximum (FWHM) spatial resolutions measured at the center of the axial field of view (radial position=1cm) were 4.3 mm and 5.1 mm in transverse and axial direction respectively. Dynamic data was measured for 120 min following bolus injection of [18F]MK6240. These subjects were allowed to take a 15 min break either at 65 min (S24, S26, S29 and S34) or at 80 min (S22) post injection. Low-dose CT acquisitions were performed right before each PET segment for the purpose of attenuation correction.
Injected PET tracer activities at the time of injection were 184.5±10.3 MBq (range: 153.2–200.9). Molar activity (Am) of [18F]MK6240 at the time of injection was 74.7±35.9 GBq/μmol (range: 11.6–151.9). Total injected mass was 992.2±848.6 ng (range: 341.5–4502.8) corresponding to 3.58±3.06 nmol (range: 1.23–16.24). Arterial blood measurements were collected for 16 subjects (8 CTRLs, 6 MCIs and 2 ADs), 10 of which on the ECAT EXACT HR+ (4 CTRLs, 5 MCIs and 1 AD) and 6 of which on the Discovery MI (4 CTRLs, 1 MCI and 1 AD). A catheter was placed in the radial artery for blood sampling to allow measurement of whole blood and plasma concentrations. Arterial blood samples of up to 1 mL were collected every 30 seconds for the 5 first minutes following radiotracer injection and frequency was progressively reduced to reach 15 minutes at the end of the scan session. Radioactivity concentration was measured in whole-blood (WB) and subsequently in plasma following the centrifugation of WB. [18F]MK6240 metabolism was measured from up to 3 mL blood samples drawn at 3, 5, 8, 15, 30, 60, 90 and up to 120 minutes throughout the scan. Radiometabolite analysis was performed using an automated column switching radioHPLC system [16,17] and eluent was fraction collected and counted on a Perkin Elmer Wizard 2480 well counter. The procedure adopted for these measurements was similar to the one described in Wooten et al. [18] except that a 62.5/37.5 sodium formate buffer/MeCN was used to backflush the catch column. Ultrafiltration measurements of plasma free fraction fp were performed in triplicate for each subject. Briefly, plasma samples were spiked with [18F]MK6240 and incubated for 15 min. Radioactive plasma solutions were added to centrifree ultrafiltation tubes that were centrifuged at 1500g for 15 minutes at room temperature. The same procedure was repeated for a control solution (PBS) spiked with [18F]MK6240 in order to correct results for binding to the ultrafiltration tube membrane and fp was calculated as fp = Cfree/Ctotal.
2.3. Image reconstruction and processing
PET reconstruction:
Dynamic PET data acquired on the ECAT EXACT HR+ (CTI/Siemens) were reconstructed using a filtered back projection algorithm while applying corrections for attenuation, scatter, random coincidences, normalization and deadtime. Final reconstructed images had matrix sizes of 128x128x63 and voxel sizes of 2.06x2.06x2.42 mm3. Dynamic PET data acquired on the Discovery MI (GE Healthcare) PET/CT scanner were reconstructed using a validated fully 3D time-of-flight iterative reconstruction algorithm using 5 iterations and 16 subsets while applying corrections for attenuation, scatter, random coincidences, normalization and deadtime. Final reconstructed images had matrix sizes of 256x256x89 and voxel sizes of 1.17x1.17x2.8 mm3. For both scanners, the time bins used to frame the emission data were 6x10s, 8x15s, 6x30s, 8x60s, 8x120s, 18x300s.
Image processing:
Dynamic PET images were motion corrected using the method described in Alpert et al. [19]. Briefly, motion correction was performed frame by frame through rigid body registration of adjacent frames using a least-squares algorithm with Levenberg-Marquardt optimization. All MR and PET images were registered into the standard Montreal Neurological Institute (MNI) space following the procedure described in Wooten et al. The dynamic PET images of the 2nd segment were summed and coregistered to the summed images of the last 20 minutes of the first dynamic segment. The resulting transformation matrix was applied to the dynamic PET images (segment 2) which were decay corrected to the start of the first dynamic acquisition. The two dynamic segments were then concatenated to form a single dynamic dataset. All MR and PET images were then registered into the standard Montreal Neurological Institute (MNI) space as follows. The first 10 minutes of the dynamic PET images were summed and rigidly co-registered to the subject’s structural MR image. The MR image itself was registered into the MNI space using a 12-parameter affine transformation followed by non-linear warping (FMRIB’s Linear Image Registration Tool [FLIRT] and FMRIB’s Non-Linear Image Registration Tool [FNIRT] in FMRIB Software Library [FSL] [20]). The transformation matrices were then combined and applied inversely on MNI and Harvard-Oxford atlases (available in FSL) to warp all atlases into the native PET images for extraction of time activity curves. The regions of interest surveyed in this work included the frontal cortex, parietal cortex, occipital cortex, temporal cortex, mesial temporal cortex, precuneus, cerebellum gray (excluding the vermis), caudate, putamen and white matter.
2.4. Arterial blood analysis
Standardized uptake value (SUV) time activity curves (TAC) of plasma and WB were generated for inter-subject comparison by correcting the measurements for subject body weight and injected dose as SUV(t) = [C(t) × BW × 1000]/ID where C(t) is the plasma or WB concentration curve in kBq/cc, ID is the injected dose in kBq and BW is body weight in kg. In order to obtain the percent parent in plasma (%PP) at the measured time points, background radioactivity was subtracted from the measurements and radioactivity eluting in the [18F]MK6240 peak was divided by the total activity. %PP measurements were then fitted to a sum of exponential decaying functions to generate %PP(t). Plasma arterial input functions of [18F]MK6240 were then generated by correcting plasma SUV TAC for [18F]MK6240 metabolism using %PP(t) as .
2.5. [18F]MK6240 brain kinetic analysis
Compartmental modeling using arterial plasma input function:
Regional TACs were analyzed with various one- (1T) and two- (2T) tissue compartment models. The 2T model was assessed in its irreversible (K1-k3 estimated, k4=0) and reversible (K1-k4 estimated) configurations. For models with reversible binding, the outcome of primary interest was the macroparameter VT (total volume of distribution, the equilibrium ratio of tracer in tissue relative to plasma which is linearly related to tracer binding to tau). Following the consensus nomenclature for imaging of reversibly binding radioligands [21], in the 1T model K1 (mL/min/cc) represents the rate constant for transfer from arterial plasma to tissue and k2 (min−1) the efflux rate constant of tracer from tissue to plasma, with total volume of distribution calculated as VT = K1/k2. In the 2T model, total volume of distribution is calculated as VT=K1/k2(1+k3/k4). Here, K1 represents the rate of transfer from plasma to the non-displaceable compartment in tissue, k2 represents efflux from the non-displaceable compartment back to plasma, k3 (min−1) represents tracer binding from the non-displaceable compartment to the specifically bound compartment, and k4 (min−1) represents tracer unbinding from the specific binding compartment back to non-displaceable compartment. Alternatively, k2 may represent efflux from a free tissue compartment, k3 may represent binding to a non-specific binding compartment, and k4 may represent unbinding from non-specifically bound to free compartment; this situation is mathematically indistinguishable from the aforementioned case where k3 and k4 represent specific binding and unbinding processes. All models were evaluated with the contribution of radioactivity in WB to the PET signal included as a model parameter v, and also with this vascular contribution fixed to v=0.05. Distribution volume ratios were calculated indirectly as DVR = VT(target)/VT(reference) using cerebellar gray matter as the reference tissue as described below.
Graphical analysis using arterial plasma input function:
The Logan and multilinear analysis MA1 graphical analysis techniques [22,23] were also applied to ROI-based TACs and their outcomes were compared to the VT calculated from the micro-parameters estimated by the full compartmental modeling analysis.
Reference region methods:
All reference region-based analysis was performed using the cerebellar gray matter excluding the vermis. The Logan graphical method with a reference region input function [24] and MRTM2 [25] were investigated for the estimation of the distribution volume ratio (DVR). For both methods, an average tissue-to-plasma efflux constant was used and was fixed to the average of k′2 cerebellar values ( = 0.0126 ± 0.0051min−1) calculated from the 2T4k1v microparameters across subjects scanned with arterial blood sampling (as in Equation 5 from Logan 2003 [26]). We also investigated the use of the full reference tissue model (FRTM) [27] as well as simplified reference tissue model (SRTM) [28].
The most simplified analysis investigated in this work relied on the standard uptake value (SUV). SUV ratios (SUVR) were calculated from PET data acquired from 70 to 90 minutes (SUVR70-90min) and from 90 to 120 minutes (SUVR90-120min) post tracer injection.
The outcomes of these reference region-based methods were compared to DVR estimates obtained from compartmental modeling with arterial plasma input function using the full duration of the PET acquisition. SUVR70-90min and SUVR90-120min were also compared to DVR estimated with Logan and MRTM2 using the full duration of the PET acquisition. For FRTM and SRTM, DVR was calculated from the estimated binding potential BP as DVR = BP + 1.
Time stability of model estimates and t* of graphical methods:
Stability of VT and DVR estimates was assessed for each method by progressively truncating the PET data in 10 min increment from the full duration of acquisition down to 50 min. For all graphical methods, the optimal choice for the cutoff time t* was determined empirically by systematically varying t* in 5 min increment from 15 to 60 min and assessing linearity of the transformed data as well as stability of resulting VT or DVR estimates.
Parametric imaging:
Dynamic PET images were smoothed with a 3-mm full width at half maximum (FWHM) Gaussian filter and SUVR70-90min as well as SUVR90-120min parametric images were generated.
2.6. Statistical analysis
The Akaike information criterion (AIC) was used to assess the relative goodness of fit for alternative compartment models [29]. AIC weights were computed as to demonstrate the probability of one model being favored over the others, where i is the model evaluated, k the total number of models tested in this work and Δi = AICi – AICmin with AICmin the lowest AIC value for the time-activity curve being considered [30]. Quantification methods were compared by linear regressions of DVR measures. The coefficient of determination R2 and t distribution of the Fisher transformation was used to generate p values for linear regressions. All data are expressed as mean value +/− one standard deviation (SD) unless otherwise specified. A p value of 0.05 or less was considered statistically significant.
3. Results
Participants
Table 1 summarizes the subject demographics. A total of 35 subjects participated in this study. All CTRL subjects (N=18) but three had a CDR global score of 0 and MMSE≥27. Other participants met the national institute of aging (NIA) research criteria for MCI with a CDR=0.5 (N= 11) or for AD with a global CDR=1 (N=6). Sixteen subjects (4 CTRLs, 6 MCIs and 6 ADs) were amyloid-β positive as defined by a FLR DVR>1.2 [12]. The CTRL and MCI/AD groups were well matched in age (69.0±13.6 VS 67.9±11.6, p=0.7959; two-sample t-test). 8 CTRL, 6 MCI and 2 AD subjects had arterial blood sampling.
Arterial input function and blood analysis
WB radioactivity time course was consistent across subjects and studies (Figure 1.a). WB to plasma ratio was 0.66±0.01 after 15 min and reached a plateau. Percent parent in plasma (%PP) best followed a single exponential (T1/2: 5.43±0.68 min) and revealed rapid metabolism with 15.3±2.8% of plasma activity attributable to unmetabolized [18F]MK6240 at 15 min and only 6.1±2.3% at 90 min (Figure 1.b). Primarily polar and moderately polar metabolites were observed on HPLC. An example of time course of the different components quantified from the radioHPLC fraction chromatogram is represented Figure 1.c. On average, no differences in metabolism was found between the CTRL and MCI/AD groups (p=0.1819, two-sample t-test on T1/2 values). Figure 1.d shows the resulting metabolite corrected arterial input functions. Plasma free fraction (fp) was 0.18±0.05 across subjects. No significant differences in fp was found between CTRL and MCI/AD groups (p=0.4251, two-sample t-test). Since fp was consistent across subjects and no significant differences was found between groups, fp was not included in the arterial input function for subsequent analysis.
Fig. 1:

Arterial blood and plasma data. (a) Mean time course of whole-blood SUV across all subjects with corresponding SD. (b) %Parent in plasma PP of [18F]MK6240 plotted for all subjects. (c) Time course of [18F]MK6240 breakdown in subject S13 with polar, moderately nonpolar, and 18F-MK6240 components depicted in blue, yellow and red respectively. (d) [18F]MK6240 SUV time course in plasma (metabolite-corrected input function).
[18F]MK6240 kinetics in brain
In CTRLs, brain uptake and kinetics were homogenous across brain regions and subjects. [18F]MK6240 peaked quickly in gray matter 2–5 SUV at ~3 minutes followed by fast washout. MCI subjects demonstrated greater inter-region as well as inter-subject heterogeneity in terms of uptake and kinetics. According to Akaike information criterion (AIC) and visual inspection, for all subjects and brain regions investigated, the preferred compartment model (AICweight,median = 1) was a reversible two-tissue model with vascular contribution (2T4k1v) included as a model parameter (Figure 2). A reversible two-tissue model with vascular contribution v fixed to v=0.05 (2T4k) provided VT estimates that were in good agreement with those obtained from the 2T4k1v model (y=1.07x-0.26, R2=0.99, p<0.0001, mean difference: 0.23±0.70 mL.cm−3), except for one subject for which data points of six regions were outside the limit of agreement of the Bland Altman plot (data not shown). DVR values estimated from these two models were in excellent agreement (y=1.02-0.02, R2=0.99, p<0.0001, mean difference: 0.003±0.057) for all subjects and brain regions surveyed in this work. Other models tested gave relatively poor model fits and therefore were found to be insufficient. The total volume of distribution (VT) ranged from 3.9-8.1 mL.cm−3 in gray matter and 3.1-5.7 mL.cm−3 in white matter for CTRL subjects. MCI/AD subjects demonstrated a wide range of VT and the highest value was found in the precuneus of an MCI subject (S9) with a VT of 50.2 mL.cm−3. Table 2 shows the mean of kinetic parameters as well as SD derived from the 2T4k1v model across CTRL and MCI/AD groups. As shown in Supplemental Figure 1, VT was highly correlated with the volume of distribution of the second compartment (K1k3/k2k4) (y=1.01x+2.16, R2=0.99, p<0.0001) as well as with k3/k4 (y=2.28x+1.96, R2=0.87, p<0.0001). In contrast, the correlation of VT with the volume of distribution of the first compartment (K1/k2) was very weak (R2=0.05, p=0.001). No significant differences in cerebellar VT were found between the CTRL and MCI subject groups (6.8±2.0 mL.cm−3 VS 6.3±1.7 mL.cm−3, p=0.6027, unpaired t-test). As shown in Supplemental Figure 2, no significant correlation was found between VT and K1 (R2=0.001, p=0.7133), and a weak but statistically significant negative correlation was observed between SUVR90-120min and K1 (R2=0.02, p=0.03).
Fig. 2:

[18F]MK6240 kinetics in different brain regions (cerebellum, mesial temporal cortex MTC, frontal cortex, occipital cortex, parietal cortex and temporal cortex). (a) 2T4k1v model fits in a CTRL subject (S1). (b) 2T4k1v model fits in an AD subject (S14). Markers represent dynamic PET measurements and solid lines depict model fits.
Table 2 :
Mean ± SD of 2T4k1v kinetic parameters obtained for CTRL subjects and MCI/AD group.
| Subject | Region | K1 (mL/min/cc) | k2 (min−1) | k3 (min−1) | k4 (min−1) | Vascular fraction v | VT (mL/cc) |
|---|---|---|---|---|---|---|---|
| CTRLs | Cerebellum | 0.398±0.082 | 0.161±0.029 | 0.015±0.004 | 0.010±0.004 | 0.041±0.031 | 6.8±2.0 |
| Precuneus | 0.409±0.115 | 0.183±0.042 | 0.016±0.003 | 0.010±0.003 | 0.045±0.035 | 6.3±1.6 | |
| MTC | 0.287±0.065 | 0.132±0.027 | 0.016±0.002 | 0.015±0.006 | 0.048±0.028 | 4.8±1.2 | |
| Caudate | 0.344±0.120 | 0.149±0.049 | 0.014±0.006 | 0.019±0.008 | 0.035±0.036 | 4.1±0.9 | |
| Hippocampus | 0.307±0.071 | 0.136±0.030 | 0.016±0.003 | 0.016±0.006 | 0.050±0.032 | 4.7±1.0 | |
| Putamen | 0.456±0.118 | 0.149±0.045 | 0.013±0.003 | 0.021±0.009 | 0.045±0.050 | 5.3±1.6 | |
| FrontalLobe | 0.368±0.106 | 0.183±0.043 | 0.017±0.002 | 0.009±0.002 | 0.048±0.032 | 5.8±1.2 | |
| OccipitalLobe | 0.409±0.110 | 0.179±0.043 | 0.018±0.003 | 0.011±0.003 | 0.038±0.035 | 6.3±1.8 | |
| ParietalLobe | 0.375±0.104 | 0.176±0.040 | 0.017±0.003 | 0.011±0.003 | 0.042±0.029 | 5.7±1.4 | |
| TemporalLobe | 0.337±0.093 | 0.150±0.033 | 0.016±0.002 | 0.010±0.004 | 0.041±0.026 | 6.1±1.7 | |
| White matter | 0.193±0.033 | 0.122±0.023 | 0.044±0.013 | 0.029±0.008 | 0.032±0.018 | 4.1±1.0 | |
| Subject | Region | K1 (mL/min/cc) | k2 (min−1) | k3 (min−1) | k4 (min−1) | Vascular fraction v | VT (mL/cc) |
| MCIs/ADs | Cerebellum | 0.363±0.075 | 0.161±0.039 | 0.015±0.004 | 0.009±0.003 | 0.036±0.025 | 6.3±1.7 |
| Precuneus | 0.334±0.061 | 0.163±0.047 | 0.030±0.021 | 0.009±0.004 | 0.031±0.030 | 13.2±15.3 | |
| MTC | 0.250±0.036 | 0.127±0.029 | 0.027±0.008 | 0.009±0.004 | 0.050±0.026 | 9.7±5.5 | |
| Caudate | 0.229±0.086 | 0.129±0.036 | 0.020±0.005 | 0.017±0.008 | 0.028±0.022 | 3.9±1.2 | |
| Hippocampus | 0.268±0.044 | 0.136±0.023 | 0.026±0.009 | 0.011±0.005 | 0.049±0.026 | 8.2±5.7 | |
| Putamen | 0.414±0.068 | 0.141±0.041 | 0.018±0.005 | 0.018±0.008 | 0.038±0.029 | 6.7±2.9 | |
| FrontalLobe | 0.295±0.051 | 0.170±0.040 | 0.022±0.009 | 0.008±0.003 | 0.033±0.023 | 7.4±4.8 | |
| OccipitalLobe | 0.325±0.060 | 0.162±0.039 | 0.027±0.011 | 0.008±0.004 | 0.028±0.025 | 11.8±9.3 | |
| ParietalLobe | 0.281±0.048 | 0.153±0.045 | 0.029±0.017 | 0.008±0.003 | 0.033±0.024 | 11.8±12.1 | |
| TemporalLobe | 0.262±0.050 | 0.132±0.035 | 0.031±0.014 | 0.007±0.003 | 0.033±0.021 | 13.8±10.1 | |
| White matter | 0.190±0.020 | 0.126±0.041 | 0.042±0.010 | 0.022±0.007 | 0.030±0.016 | 5.2±2.6 |
Simplified methods
Logan plots did not linearize well for all datasets. Nonetheless, using a 40-min t*. VT estimated by Logan graphical method correlated very well with VT calculated from the micro-parameters obtained from the full compartmental modeling analysis (y=0.93x+0.39, R2=0.99. p<0.0001; mean difference: −0.10±0.63 mL.cm−3; Figure 3.a). The VT estimates obtained with MA1 (with t*=40 min) were also highly correlated and in good agreement with those obtained from the reversible two-tissue compartment model (y=0.96x+0.28, R2=0.99, p<0.0001; mean difference: −0.01±0.61 mL.cm−3; Figure 3.b).
Fig. 3:

Comparisons between blood-based analysis methods. (a) Correlation plots of Logan VT against VT calculated from the 2T4k1v model. (b) Correlation plots of MA1 VT against VT calculated from the 2T4k1v model. Red lines represent linear regression and gray dashed lines are lines of identity.
Logan graphical method using cerebellar input functions for calculation of DVR linearized very well by a t* of 40 min. As shown on Figure 4.a. and 4.b, Logan DVR and MRTM2, using an estimated average tissue-to-plasma efflux constant , were highly correlated with DVR estimates obtained from the 2T4k1v model (2T4k1v DVR), but the slope was less than unity (y=0.79x+0.20, R2=0.99, p<0.0001; Figure 4.a and y=0.80x+0.21, R2=0.99, p<0.0001; Figure 4.b). Consequently, MRTM2 and Logan DVR were in excellent agreement (y=1.02x-0.01, R2=0.99, p<0.0001; Figure 4.c.). DVR estimated from FRTM were linearly correlated with 2T4k1v DVR but strongly underestimated blood-based DVR (y=0.55x+0.74, R2=0.80, p<0.0001; data not shown). The same observation was made for SRTM (y=0.57x+0.50, R2=0.88, p<0.0001; data not shown). Finally, SUVR70-90min and SUVR90-120min were also both highly correlated with 2T4k1v DVR but showed a marked underestimation for DVR>3 best described by univariate quadratic functions (R2=0.95, p<0.0001; Figure 4.d. and R2=0.97, p<0.0001; Figure 4.g., respectively). For 2T4k1v DVR<3, both SUVR70-90min and SUVR90-120min show high linear correlations with 2T4k1v DVR with slope close to unity (y=0.90x+0.11, R2=0.93, p<0.0001; Figure 4.d. and y=0.94x+0.07, R2=0.95, p<0.0001; Figure 4.g., respectively). SUVRs showed good linear correlations with Logan DVR (SUVR70-90min: y=0.86x0.17, R2=0.95, p<0.0001; Figure 4.e. and SUVR90-120min: y=0.93x+0.06, R2=0.97, p<0.0001; Figure 4.h.) as well as with MRTM2 DVR (SUVR70-90min: y=0.84x0.17, R2=0.96, p<0.0001; Figure 4.f. and SUVR90-120min: y=0.92x+0.07, R2=0.97, p<0.0001; Figure 4.i.) despite a small underestimation of DVR values. Corresponding Bland-Altman plots between the different model outcomes are shown in Supplemental Figure 3.
Fig. 4:

(a-i) Correlation plots showing the relationship between the outcomes of different quantification methods surveyed in this work: 2T4k1v DVR, Logan DVR (with cerebellar input functions), MRTM2 DVR, SUVR70-90min and SUVR90-120min. Red lines represent linear regression and gray dashed lines are lines of identity. Black dashed lines in d, g represent fits obtained with univariate quadratic functions and are meant to highlight the roll-off effect observed for 2T4k1v DVR>3. Data points presented on these plots are from all subjects and brain regions surveyed in this work.
Time stability of model estimates and SUVR
Figure 5 shows the time stability of VT and DVR estimates in the temporal cortex of CTRL and MCI/AD subjects. Blood-based methods (2T4k1v, Logan and MA1 graphical methods) showed an increasing underestimation of VT estimates as the scan duration was truncated down to 50 min. This underestimation was greater in high-binding regions of MCI/AD subjects than in CTRLs. Furthermore, Logan and MA1 graphical methods were more affected than the 2T4k1v model (Figure 5 a–c), consistent with the relatively poor level of linearization observed. In contrast, DVR estimates of reference-based graphical methods were more stable with time (Figure 5 d–e). Lastly, SUVR was still increasing at 135 min post injection in very high binding regions of MCI/AD subjects while it was stable by 30 min in CTRL subjects (Figure 5.f).
Fig. 5:

(a-e) Time stability of VT and DVR estimates in the temporal cortex for the different methods surveyed in this work with truncated acquisition times down to 50 minutes post tracer injection. For each method, bias was calculated by taking the full acquisition as the reference. (f) SUVR time course in the precuneus measured for a representative CTRL subject (S1) and for an MCI subject showing high [18F]MK6240 uptake (S9). Blue markers are for control subjects and red markers are for MCI/AD subjects. a-e show mean and SD calculated across subjects.
Parametric imaging
Figure 6 shows SUVR70-90min and SUVR90-120min maps for all subjects studied in this work, as well the corresponding MRI slices for anatomical reference. All MCI/AD subjects presenting elevated [18F]MK6240 binding were also Amyloid-β positive. Moreover, none of the CTRL subjects exbhibited [18F]MK6240 uptake consistent with neurofibrillary tau deposition patterns established in the literature. For the most part, off-target binding was concordant with what was previously reported in Betthauser et al. [9]. In particular, all subjects demonstrated significant binding in the ethmoid sinus as well as in the retina (likely binding to melanin). All CTRL subjects as well as most of the MCI/AD subjects exhibited various degrees of uptake in the meninges.
Fig. 6 :

SUVR parametric images of [18F]MK6240 for all subjects using the cerebellum as reference region. All images were registered into the MNI template space. Panel (a) shows CTRL subjects and panel (b) shows MCI/AD subjects. Within each group, subjects were sorted by PiB scores when applicable. Amyloid-β positive scores are highlighted in yellow. In each panel, first row shows the corresponding individual MPRAGE images for anatomical reference.
4. Discussion
[18F]MK6240 was developed for in-vivo quantification of NFT, and despite rapid adoption in human imaging studies there have to date been only limited reports on characterization of pharmacokinetics and data analysis strategies. In this work, we extended previous works to provide a comparison of the different pharmacokinetic modeling strategies ranging from the more complex fully quantitative methods using arterial blood sampling to the simpler SUVR analysis.
Quantification using arterial blood data
[18F]MK6240 kinetics was best described with a reversible two-tissue compartment model, with vascular contribution included as a model parameter (2T4k1v), for all subjects and for both low and high binding regions. Our findings suggest that elevated VT estimates were mostly driven by specific binding (Supplemental Figure 1). We did not find any significant correlation between VT and K1, and observed a weak but significant negative correlation between SUVR90-120min and K1, suggesting that these outcomes are not dependent on potential perfusion changes. Also, cerebellar VT estimates were not significantly different between CTRL and MCI subjects further supporting the use of the cerebellum as a reference region (i.e. devoid of specific binding) for non-invasive quantification methods. Therefore, in this work, cerebellar VT was used as an index of non-displaceable binding. Despite a relatively poor linearization of the Logan graphical method in most datasets, we observed a very good agreement in VT estimates between the arterial blood-based graphical methods (Logan and MA1) and the preferred 2T4k1v model when using a 40-min t*.
Reference region methods and SUVR
We examined simplified methods for quantification of [18F]MK6240 uptake using the cerebellum as a reference region. DVR from FRTM and SRTM linearly correlated with blood-based DVR estimates but demonstrated a significant underestimation and therefore were not further investigated. The reason of this underestimation, seen despite relatively good model fits in high binding regions, can be explained by violation(s) of at least one of the model assumptions [31]. In particular, one of the model assumptions that was violated is the description of the kinetic behavior of the tracer by a 1T model in the reference region for FRTM and; in the reference and target tissues for SRTM. Indeed, for all brain regions the time activity curves (including for the reference region used in this work) were best fitted by a two-tissue model and a simple one-tissue model clearly failed to fit the data. As specified in the methods, for both Logan DVR and MRTM2, we used an estimated average tissue-to-plasma efflux constant fixed to the average of k′2 cerebellar values calculated from the 2T4k1v microparameters across subjects scanned with arterial blood sampling. These reference region-based graphical methods (Logan and MRTM2) and late SUVRs were highly correlated with DVR estimates obtained from compartmental modeling and arterial sampling (DVR2T4k1v) but underestimated DVR2T4k1v at DVR >3. Underestimation of 2T4k1v DVR by the graphical methods were due to the error term [24, 26], since using individual k′2 cerebellar estimates to perform a similar comparison as in Figure 4.a. provided better agreement (y=0.92+0.08, R2=0.99, p<0.0001; mean difference: −0.002±0.078 mL.cm−3; data not shown). In very high binding regions (DVR2T4k1v >3), SUVR was still increasing at 135 min and therefore did not reach equilibrium throughout the scan duration (Figure 5.f), which certainly contributed to the SUVR underestimation when compared to DVR2T4k1v. This effect is likely due to the slow kinetics of [18F]MK6240 in NFT-rich region because of its subnanomolar affinity for NFTs. These underestimations at high DVR were also observed, although to a lesser extent, by Pascoal et al. in a subset of 6 subjects [11]. It was not clear however, how many subjects presented DVR values greater than 3 in their study. In contrast, Lolith et al. also presented good correlations between reference region-based methods and DVR2T4k1v using 90 min of PET data but reported different slopes across subjects. However, all their MCI/AD subjects (N=3) exhibited DVR2T4k1v<2.5. Lastly, part of the discrepancies observed between reference region-based methods and blood-based methods may be explained by potential measurement errors due to the fast metabolism of [18F]MK6240 as discussed below.
[18F]MK6240 metabolism
[18F]MK6240 was metabolized quickly and, consequently, %PP was very low after 30 min post tracer injection (typically <10% of the radioactivity concentration measured in the plasma), which is consistent with the data reported by both Lolith et al. and Pascoal et al. [10,11]. Although arterial blood-based compartmental modeling is commonly considered as the gold standard, this fast metabolism is a potential concern for the accuracy of in-vivo quantification of NFT with [18F]MK6240 using arterial blood-based methods. Indeed, at late time points small errors in low PP can potentially introduce substantial bias in the kinetic parameters k3-k4 and therefore in VT, particularly in high-binding regions.
Limitations
One limitation of this work includes the absence of test-retest data to assess the intra-subject reproducibility of our quantitative measurements, which would be particularly useful to determine the accuracy with which we will be able to assess small changes in tau deposition at early stages of the disease, in response to therapy or for statistical or longitudinal analyses. However, we found relatively low variability in VT estimates measured accross CTRL subjects compared to the wide range of VT values measured in the MCI/AD group. These results suggest that test-retest variability would likely be low, at least in CTRLs, in view of the wide dynamic range of [18F]MK6240 signal measured across MCI and AD subjects. Nonetheless, in regard to the fast metabolism of [18F]MK6240 discussed above, test-retest studies would be particularly informative in MCI/AD subjects presenting brain regions with high density of NFT. These studies would also be very valuable to assess the reproducibility of Logan DVR and MRTM2 using a fixed value. Another limitation of the present study was the limited number of MCI/AD subjects with arterial blood sampling presenting very high DVR (DVR>3) (N=2), i.e. where we observed some discrepancies between the outcomes of the different quantification methods.
In conclusion, [18F]MK6240 seems to exhibit exquisite affinity for NFT and consequently demonstrated a wide dynamic range of uptake in MCI/AD subjects as compared to CTRLs. However, measurement of parent in plasma showed fast metabolism with little radioactivity in the parent form after 60 minutes, which is a potential concern for accurate quantification of tau aggregates using blood-based methods. For all subjects, the preferred compartmental model was a reversible two-tissue model with the vascular contribution included as a model parameter (2T4k1v). Despite not being very stable in time, the blood-based Logan and MA1 graphical methods resulted in good agreement with 2T4k1v for the estimation of VT when using a 40-min t* and the full duration of the PET measurements. Reference region-based methods correlated strongly with the full compartment analysis but underestimated DVR2T4k1v at DVR >3. Therefore, caution should be applied when using simplified methods to such data sets and in quantitative interpretation of corresponding outcomes. Moreover, in very high binding regions/subjects, SUVR was still increasing at 135 min making this simplified method sensitive to uptake time variation. In light of this observation, studies using late SUVR as a quantitative outcome will require adhering strictly to a static imaging time window.
Supplementary Material
Acknowledgements
This work was supported by the following grant: R01AG046396, S10OD018035, P41EB022544 and T32EB005876. The authors thank Julia Scotton and Nicole DaSilva for subject preparation, scanning and monitoring as well as Steven Weise and Eugene Lee for their help with data management.
Funding This study was funded by R01AG046396, S10OD018035, T32EB005876, and P41EB022544
Footnotes
Publisher's Disclaimer: This Author Accepted Manuscript is a PDF file of a an unedited peer-reviewed manuscript that has been accepted for publication but has not been copyedited or corrected. The official version of record that is published in the journal is kept up to date and so may therefore differ from this version.
Conflict of Interest Nicolas J. Guehl declares that he has no conflict of interest. Dustin W. Wooten declares that he has no conflict of interest. Daniel L. Yokell declares that he has no conflict of interest. Sung-Hyun Moon declares that he has no conflict of interest. Maeva Dhaynaut declares that she has no conflict of interest. Samantha Katz declares that she has no conflict of interest. Kirsten A. Moody declares that she has no conflict of interest. Codi Gharagouzloo declares that he has no conflict of interest. Aurélie Kas declares that she has no conflict of interest. Keith A. Johnson declares that he has no conflict of interest. Georges El Fakliri declares that he has no conflict of interest. Marc D. Normandin declares that he has no conflict of interest.
Compliance with Ethical Standards
Ethical approval All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Informed consent Informed consent was obtained from all individual participants included in the study
References
- 1.Braak H, Braak E. Neuropathological stageing of Alzheimer-related changes. Acta Neuropathol. 1991;82:239–59. [DOI] [PubMed] [Google Scholar]
- 2.Arriagada PV, Growdon JH, Hedley-Whyte ET, Hyman BT. Neurofibrillary tangles but not senile plaques parallel duration and severity of Alzheimer’s disease. Neurology. 1992;42:631–9. [DOI] [PubMed] [Google Scholar]
- 3.Villemagne VL, Fodero-Tavoletti MT, Masters CL, Rowe CC. Tau imaging early progress and future directions. Lancet Neurol. 2015;14:114–24. [DOI] [PubMed] [Google Scholar]
- 4.Okamura N, Harada R, fsliiki A, Kikuchi A, Nakamura T, Kudo Y. The development and validation of tau PET tracers: current status and future directions. Clin TranslImaging. 2018;6:305–16. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Leuzy A, Chiotis K, Gilberg PG, Almkvist O, Rodriguez-Vieitez E, Nordberg A. Tau PET imaging in neurodegenerative taupathies-still a challenge. Mol Psychiatry. 2019; doi: 10.1038/s41380-018-0342-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Hall B, Mak E, Cervenka S, Aigbirhio FI, Rowe JB, O’Brien JT. In vivo tau PET imaging in dementia: Pathophysiology, radiotracer quantification, and a systematic review of clinical findings. Ageing Res Rev. 2017;36:50–63. [DOI] [PubMed] [Google Scholar]
- 7.Walji AM, Hostetler ED, Selnick H, Zeng Z, Miller P, Bennacef I, et al. Discovery of 6-(Fluoro-(18)F)-3-(1H-pyrrolo[2,3-c]pyridin-1-yl)isoquinolin-5-amine ([(18)F]-MK-6240): A Positron Emission Tomography (PET) Imaging Agent for Quantification of Neurofibrillary Tangles (NFTs). J. Med. Chem. 2016;59:4778–89. [DOI] [PubMed] [Google Scholar]
- 8.Hostetler ED, Walji AM, Zeng Z, Miller P, Bennacef I, Salinas C, et al. Preclinical Characterization of 18F-MK-6240, a Promising PET Tracer for In Vivo Quantification of Human Neurofibrillary Tangles. J Nucl Med. 2016;57:1599–1606. [DOI] [PubMed] [Google Scholar]
- 9.Betthauser TJ, Cody KA, Zammit MD, Murali D, Converse AK, Barnhart TE, et al. In vivo characterization and quantification of neurofibrillary tau PET radioligand [18F]MK-6240 in humans from Alzheimer’s disease dementia to young controls. J Nucl Med. 2018; doi: 10.2967/jnumed.118.209650. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Loliith TG, Bennacef I, Vandenberghe R, Vandenbulcke M, Salinas-Valenzuela C, Declercq R, et al. J Nucl Med. 2018; doi: 10.2967/jnumed.118.208215. [DOI] [Google Scholar]
- 11.Pascoal TA, Shin M, Kang MS, Chamoun M, Chartrand D, Mathotaarachchi S, et al. In vivo quantification of neurofibrillary tangles with [18F]-MK-6240: Alzheimers Res Ther. 2018;10:74. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Johnson KA, Schultz A, Betensky RA, Becker JA, Sepulcre J, Rentz D, et al. Tau PET imaging in aging and early Alzheimer’s disease. Ann Neurol. 2016;79:110–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Collier TL, Yokell DL, Livni E, Rice PA, Celen S, Serdons K, et al. cGMP production of the radiopharmaceutical [18F]MK-6240 for PET imaging of human neurofibrillary tangles. J Labelled Comp Radiopharm. 2017;60:263–9. [DOI] [PubMed] [Google Scholar]
- 14.Adam LE, Zaers J, Ostertag H, Trojan H, Bellemann ME, Brix G. Performance evaluation of the whole-body PET scanner ECAT EXACT HR+ following the IEC standard. IEEE Trans Nucl Sci. 1997;44:1172–9. [Google Scholar]
- 15.Karakatsanis N, Sakellios N, Tsantilas NX, et al. Comparative evaluation of two commercial PET scanners, ECAT EXACT HR+ and Biograph 2, using GATE. Nucl Instruments Methods Phys Res Sect A Accel Spectrometers, Detect Assoc Equip 2006;569:368–72. [Google Scholar]
- 16.Collier T, Nomiandin MD, El Fakliri G, Vasdev N. Automation of column-switching HPLC for analysis of radiopharmaceuticals and their metabolites in plasma. Society of Nuclear Medicine Annual Meeting Abstracts. 2013:54:1133. [Google Scholar]
- 17.Hilton J, Yokoi F, Dannals RF, Ravert HT, Szabo Z, Wong DF. Column-switching HPLC for the analysis of plasma in PET imaging studies. Nucl Med Biol. 2000;27:627–30. [DOI] [PubMed] [Google Scholar]
- 18.Wooten DW, Guehl NJ, Verwer EE, Shoup TM, Yokell DL, Zubcevik N, et al. Pharmacokinetic Evaluation of the Tau PET Radiotracer 18F-T807 (18F-AV-1451) in Human Subjects. J Nucl Med. 2017;484–91. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Alpert NM, Berdichevsky D, Levin Z, Moms ED, Fisclunan AJ. Improved methods for image registration. Neuroimage. 1996;3:10–8. [DOI] [PubMed] [Google Scholar]
- 20.Jenkinson M Beckman CF, Behrens TEJ Woolrich MW, Smith SM. FSL. Neuroimage. 2012;62:782–90. [DOI] [PubMed] [Google Scholar]
- 21.Innis RB, Cunningham VJ, Delforge J, Fujita M, Gjedde A, Gunn RN, et al. Consensus nomenclature for in vivo imaging of reversibly binding radioligands. J Cereb Blood Flow Metab. 2007;27:1533–39. [DOI] [PubMed] [Google Scholar]
- 22.Logan J, Fowler JS, Volkow ND, Wolf AP, Dewey SL, Schlyer DJ, et al. Graphical analysis of reversible radioligand binding from time-activity measurements applied to [N-11C-methyl]-(-)-cocaine PET studies in human subjects. J Cereb Blood Flow Metab. 1990;10:740–7. [DOI] [PubMed] [Google Scholar]
- 23.Ichise M, Toyama H, Innis RB, Carson RE: Strategies to improve neuroreceptor parameter estimation by linear regression analysis. J Cereb Blood Flow Metab 2002;22:1271–81. [DOI] [PubMed] [Google Scholar]
- 24.Logan J, Fowler JS, Volkow ND, Wang GJ, Ding YS, Alexoff DL. Distribution volumes ratios without blood sampling from graphical analysis of PET data. J Cereb Blood Flow Metab. 1996;16:834–40. [DOI] [PubMed] [Google Scholar]
- 25.Ichise M, Liow JS, Lu JQ, Takano A, Model K, Toyama H, et al. Linearized reference tissue parametric imaging methods: application to [11C]DASB positron emission tomography studies of the serotonin transporter in human brain. J Cereb Blood Flow Metab 2003;23:1096–112. [DOI] [PubMed] [Google Scholar]
- 26.Logan J A review of graphical methods for tracer studies and strategies to reduce bias. Nucl Med Biol. 2003;30:833–44. [DOI] [PubMed] [Google Scholar]
- 27.Cunningham VJ, Hume SP, Price GR, Ahier RG, Cremer JE, Jones AK. Compartmental analysis of diprenorphine binding to opiate receptors in the rat in vivo and its comparison with equilibrium data in vitro. J Cereb Blood Flow Metab. 1991;11:1–9. [DOI] [PubMed] [Google Scholar]
- 28.Lammertsma AA, Hume SP. Simplified reference tissue model for PET receptor studies. Neuroimage. 1996;4:153–8. [DOI] [PubMed] [Google Scholar]
- 29.Akaike H A new look at the statictical model identification. IEEE Transactions on Automatic Control. 1974;19:716–23. [Google Scholar]
- 30.Burnham KP, Andersen DR. Model Selection and Multimodel Inference: A practical Information-Theoretic Approach. 2nd ed New York, NY: Springer; 2002. [Google Scholar]
- 31.Salinas CA, Searle GE, Gunn RN. The simplified reference tissue model: model assumption violations and their impact on binding potential. J Cereb Blood Flow Metab. 2015;35:304–11. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
