Skip to main content
Jornal Vascular Brasileiro logoLink to Jornal Vascular Brasileiro
. 2019 Aug 29;18:e20190009. doi: 10.1590/1677-5449.190009
View full-text in Portuguese

Influence of linear intravenous energy density on the success of intravenous laser ablation for treatment of chronic venous insufficiency

Luiza de Freitas Heineberg 1, Adriana Buechner de Freitas Brandão 1,2,, Filipe Carlos Caron 2, Jaqueline Beirith 1, Walter Junior Boim de Araujo 2
PMCID: PMC6718192  PMID: 31497034

Abstract

Background

It is relevant to elucidate the influence that mean linear endovenous energy density (LEED) has on the success of endovenous laser ablation treatment for chronic venous insufficiency, in order to reduce the method’s adverse effects.

Objectives

To evaluate the influence of mean LEED on the prevalence of saphenous closure 30 days after the laser ablation procedure.

Methods

153 lower limbs from 118 patients seen at a tertiary hospital and treated for chronic venous insufficiency with endovenous 1470 nm laser ablation under local anesthesia were evaluated. The mean LEED used to treat patients was calculated to determine whether greater than average LEED was required for treatment success.

Results

A significant difference (p = 0.021) in saphenofemoral junction closure was associated with mean LEED used above the knee. Conversely, there was no significant difference in the thigh segment.

Conclusions

Linear intravenous energy density greater than the mean of 70.57 J/cm was associated with a higher rate of closure at the saphenofemoral junction. However, density did not have an influence on the result for the thigh segment, showing that an energy density exceeding 70.57 J/cm tends not to be required for treatment of this segment.

Keywords: venous insufficiency, laser, saphenous vein, varicose veins

INTRODUCTION

Chronic venous insufficiency (CVI) is a common disease in the vascular surgeon’s office, affecting 25 to 33% of women and 10 to 20% of men in the adult Western population.1 It is directly related to work absenteeism and to public healthcare expenditure.2 Considering this socioeconomic importance, studying new techniques that can enable effective treatment with better results is generating increasing interest, particularly with relation to rates of relapse, to complications, and to early return to daily activities.3

Treatments for CVI include: clinical management and lifestyle changes; foam sclerotherapy and varicose vein surgery using the mini-incisions technique; saphenectomy by fleboextraction; and endoluminal methods such as radio frequency and laser thermoablation (endovenous laser ablation, EVLA).4 - 7

The minimally invasive techniques are alternatives to conventional surgical treatment with great saphenous vein (GSV) stripping and they have been increasingly adopted within medical practice.5 , 6 Of these, EVLA stands out for its favorable results in terms of saphenous closure rates, patient satisfaction, and reduced post-procedure morbidity.3 , 8 , 9

In view of the growing acceptance of EVLA as an alternative method to stripping for treatment of CVI,10 this study was conducted with the intention of elucidating what influence linear endovenous energy density (LEED) has on the outcome of the procedure at 30 days.

METHODS

This was a retrospective study, that reviewed medical charts for 193 patients with CVI seen at a tertiary hospital, treated with EVLA, and reassessed 30 days later. The project was approved by the institutional Ethics Committee and registered under protocol number 80030817.0.00005580 on the Plataforma Brasil.

The inclusion criteria were patients with CVI treated with EVLA from the saphenofemoral junction (SFJ) to the knee at the Hospital Angelina Caron from 2011 to February of 2018. Exclusion criteria were: patients who did not return for the 30-day follow-up; patients with peripheral arterial disease, severe hypercoagulation syndromes, or a history of deep venous thrombosis or deep venous insufficiency; and patients with incomplete medical records.

A total of 153 lower limbs were analyzed from 118 patients who had been treated with EVLA for CVI. The procedure was initiated with the patient in decubitus dorsal. Anesthetic was applied to the puncture site and ultrasound-guided puncture of the GSV was conducted using an Abocath®16, preferably at a point distal of the last tributary vein with reflux, followed by insertion of a 6F valved introducer. Next, the optical fiber (radial or linear) was inserted and connected to an endovenous laser energy source with a standard wavelength of 1470 nm (registered with the Agência Nacional da Vigilância Sanitária, under number 80058580018).

Once the endoluminal position within the GSV at 2.5 cm distal of the SFJ had been confirmed, tumescent local anesthesia was administered along the course of the GSV being treated. A syringe or mechanical infusion pump was used to administer a solution comprising 250 mL 0.9% saline to 20 mL of 2% lidocaine and adrenaline 1:100,000 with 4 mL of 8.4% sodium bicarbonate (Figure 1). Once anesthesia was complete, the position of the fiber at 2.5 cm from the junction was confirmed once more and the laser activated (Figure 2). The fiber was tractioned manually and continuously, in the caudal direction up to the distal limit of the saphenous vein being treated.11

Figure 1. Initiating tumescent anesthesia induction with ultrasound control.

Figure 1

Figure 2. Confirmation of fiber position by transillumination (A) and ultrasound control (B).

Figure 2

After the procedure, dressing was applied, exerting extrinsic compression along the path of the GSV, using cotton wool pads and 7/8 high compression elastic stockings (30-40 mmHg). Patients were discharged from hospital on the same day as the operation, after approximately 2 hours of postoperative observation, with a 5-day prescription for analgesics and nonsteroidal anti-inflammatories. The elastic stockings were left in place for 48 hours and removed by the patients themselves. From the third day onwards, the patient wore the stockings during the day and removed them for bathing and sleeping. Although there were no specific restrictions on walking, patients were advised to spend around 40 minutes of each hour at rest with legs raised.

Patients were reassessed at 7 and 30 days after surgery, with physical examination and Doppler vascular echography (Figure 3). The most important factors analyzed were: presence or absence of paresthesia, phlebitis, and deep venous thrombosis in the treated lower limb and the rates of GSV obliteration and absence of reflux.

Figure 3. Control ultrasound examination at 7 postoperative days, demonstrating absence of flow in the saphenous vein.

Figure 3

Ultrasound assessment of absence of reflux at the SFJ followed the recommendations contained in the clinical practice guidelines for patients with varicose veins and venous diseases published by the Society for Vascular Surgery and the American Venous Forum. A positive result was defined as absence of patent GSV stump and no reflux. For analysis, patients were classified as absence of patent stump, partially patent stump, or presence of reflux (Table 1).

Table 1. Classification of results of Doppler ultrasonography at the saphenofemoral junction after thermal ablation.

Patency J0 Absence of patent stump
J1, J2, J3, J4, etc. Junction with 1, 2, 3, 4 cm, etc. patent stump
Reflux R+ Reflux
R- No reflux

Statistical analysis

Data were collected from medical records and stored in a Microsoft Excel spreadsheet. Data analysis was conducted with the help of SPSS, version 22.0.

Results were expressed using descriptive statistics. Inferential analysis used Pearson’s chi-square test, Fisher’s exact test, Student’s t test for parametric variables and the Mann-Whitney test for nonparametric variables. Results with p values below 0.05 were considered significant.

RESULTS

A total of 193 patient records were analyzed and 118 records and 153 lower limbs were selected for analysis. The majority of the study population were female (55.9%) and overweight (mean body mass index [BMI] was 29.67] and the average age was 55.35 years. A two-ring radial fiber was used in 66.8% and a linear fiber was used in 33.2% of the patients, both with a 600 µ diameter, and power was 6 watts. Descriptive statistics for the data are shown below in tables, by age and BMI (Table 2), by sex (Table 3), and by complications (Table 4).

Table 2. Descriptive statistics for age and BMI data.

Statistical analysis Age (years) BMI (kg/m2)
n 118 118
Mean 52.35 29.67
Standard deviation 11.74 5.57

BMI, body mass index.

Table 3. Descriptive statistics for sex.

Sex Frequency Percentage
Female 66 55.9
Male 52 44.1
Total 118 100.0

Table 4. Descriptive statistics for data on postprocedural complications in 118 patients.

Complication Frequency Percentage
DVT 1 0.8
Paresthesia 31 26.3
Phlebitis 16 13.5

DVT, deep venous thrombosis.

There were significant differences between the outcome groups (absence of patent stump, partially patent stump, and presence of reflux) with relation to mean LEED administered, according to analysis of variance (ANOVA), with p = 0.021 (Table 5). The Bonferroni post-hoc test showed that there was a significant difference when the absence of patent stump group was compared with the presence of reflux group (p = 0.017) and also comparing the partially patent stump group to the presence of reflux group (p = 0.032) (Table 6).

Table 5. Results of the ANOVA test of the relationship between LEED administered and closure of the GSV at the SFJ.

Population Sum of squares df Mean square Z p
Intergroup 1453.727 2 726.863 3.978 0.021
Intragroup 27409.025 150 182.727
Total 28862.751 152

ANOVA, analysis of variance; df, degrees of freedom; SFJ, saphenofemoral junction; LEED, linear intravenous energy density; GSV, great saphenous vein.

Table 6. Mean LEED values and standard deviations for groups with absence of patent stump, partially patent stump, and presence of reflux at the SFJ.

Anatomic reference n Mean (J/cm) Standard deviation (J/cm)
Absence of patent stump 41 72.59b 12.18
Partially patent stump 109 70.38b 12.71
Presence of reflux 3 49.90a 44.80
Total 153 70.57 13.77

SFJ, saphenofemoral junction; LEED, linear intravenous energy density; Different letters denote results with significant difference according to the Bonferroni test.

With relation to the type of fiber used and the LEED administered, there was a trend towards significant difference, according to the Levine test, with p = 0.084. According to this test, the linear fiber needed a higher LEED, of 73.30, compared to mean LEED of 69.21 for the radial fiber. When saphenous closure and presence of reflux were compared by type of fiber used, there was no significant difference (p = 0.174), according to the chi-square test.

DISCUSSION

Chronic venous insufficiency can be defined as a condition of the superficial and/or deep venous system. The disease’s prevalence has been growing worldwide and increases with age. A study conducted with a population from Botucatu, in the Brazilian state of São Paulo, reported a 35.5% prevalence of varicose veins.12 - 14

Currently, studies investigating EVLA are attempting to identify safer ways of employing it, with fewer adverse effects. They analyze variables such as the wavelength and energy employed, the velocity at which the laser is applied, and different types of optical fibers.10

The laser light emitted from the generator causes a thermal reaction in which the laser energy delivered is captured by the intracellular water in the endothelial cells of the saphenous vein. This mechanism of action can be regulated by physical parameters, such as wavelength, method of energy administration, and quantity of energy per surface area.15 , 16

The level of energy absorbed is extremely important, since the vessel will only retract once it reaches a certain level and, if this is not achieved, the vein may remain open or recanalize.17 - 19 Conversely, an excessive amount of energy could injure adjacent tissues, such as nerves and lymph vessels. LEED is one of the most prominant variables during the procedure, and some studies have correlated energy density with favorable or unfavorable results.13 , 20 - 22

The term LEED was first used in 2005 and became the reference for calculation of the energy used in the procedure because of its simplicity and the possibility of standardization. The formula used takes into account the power used and the velocity at with the optical fiber is tractioned.12

In the lower limbs assessed in this study, mean LEED was 70.57 J/cm and it was observed that LEED exceeding this mean was necessary to achieve effective thermal ablation at the SFJ. The higher energy level provoked partial or complete obliteration at the SFJ and an absence of reflux. Similar results were observed by Proebstle et al.17

CONCLUSIONS

At 30 days follow-up of patients treated for CVI under local anesthesia with EVLA, it was observed that at the SFJ using a LEED exceeding a mean of 70.57 J/cm was associated with better results, with higher rates of obliteration and absence of reflux, in relation to lower LEED. There was no significant difference in the thigh segment. This prompts the conclusion that for this segment it is not necessary to employ such a high energy level in order to achieve the desired results, and it is therefore possible to employ a lower LEED to reduce the chance of complications.

Although these results are compatible with the literature, further studies are needed with data specifically relating to the LEED applied at the SFJ and in the thigh, and their relationship with the incidence of paresthesia.

Footnotes

How to cite: Heineberg LF, Brandão ABF, Caron FC, Beirith J, Araujo WJB. Influence of linear intravenous energy density on the success of intravenous laser ablation for treatment of chronic venous insufficiency. J Vasc Bras. 2019;18:e20190009. https://doi.org/10.1590/1677-5449.190009

Financial support: None.

The study was carried out at Hospital Angelina Caron and Faculdades Pequeno Príncipe, Curitiba, PR, Brazil.

REFERENCES

  • 1.Brito C, Duque A, Loureiro E, Merlo IFVL., Fo . Insuficiência venosa crônica - conceito, classificação e fisiopatologia. In: Brito CJ, Murilo R, editors. Cirurgia vascular: cirurgia endovascular, angiologia. 3. Rio de Janeiro: Thieme Revinter; 2014. pp. 1001–1011. [Google Scholar]
  • 2.Belczak CEQ, Godoy JMP, Ramos RN, Oliveira MA, Belczak SQ, Caffaro RA. Influência do turno laboral na formação de edema dos membros inferiores em indivíduos normais. J Vasc Bras. 2008;7(3):225–230. doi: 10.1590/S1677-54492008000300007. [DOI] [Google Scholar]
  • 3.Schoonover JP, King JT, Gray C, Campbell K, Sherman C. 3 alternatives to standard varicose vein treatment. J Fam Pract. 2009;58(10):522–526. [PubMed] [Google Scholar]
  • 4.Wittens C, Davies AH, Bækgaard N, et al. Editor’s choice - management of chronic venous disease: clinical practice guidelines of the European Society for Vascular Surgery (ESVS) Eur J Vasc Endovasc Surg. 2015;49(6):678–737. doi: 10.1016/j.ejvs.2015.02.007. [DOI] [PubMed] [Google Scholar]
  • 5.Bountouroglou DG, Azzam M, Kakkos SK, Pathmarajah M, Young P, Geroulakos G. Ultrasound-guided foam sclerotherapy combined with sapheno-femoral ligation compared to surgical treatment of varicose veins: early results of a randomised controlled trial. Eur J Vasc Endovasc Surg. 2006;31(1):93–100. doi: 10.1016/j.ejvs.2005.08.024. [DOI] [PubMed] [Google Scholar]
  • 6.Gloviczki P, Comerota AJ, Dalsing MC, et al. The care of patients with varicose veins and associated chronic venous diseases: clinical practice guidelines of the Society for Vascular Surgery and the American Venous Forum. J Vasc Surg. 2011;53(5) Suppl:2S–48S. doi: 10.1016/j.jvs.2011.01.079. [DOI] [PubMed] [Google Scholar]
  • 7.Pereira AF, Mesquita A, Gomes C. Abordagens cirúrgicas no tratamento de varizes. Angiol Cir Vasc. 2014;10(3):132–140. doi: 10.1016/j.ancv.2014.08.003. [DOI] [Google Scholar]
  • 8.Zimmet SE. Sclerotherapy treatment of telangiectasias and varicose veins. Tech Vasc Interv Radiol. 2003;6(3):116–120. doi: 10.1053/S1089-2516(03)00044-1. [DOI] [PubMed] [Google Scholar]
  • 9.Nejm CS, Jr, Timi JR, Araújo WB, Jr, Caron FC. Endovenous laser ablation of the great saphenous vein - Varying energy may not affect outcome. Phlebology. 2017;32(1):13–18. doi: 10.1177/0268355515620944. [DOI] [PubMed] [Google Scholar]
  • 10.Galanopoulos G, Lambidis C. Minimally invasive treatment of varicose veins: Endovenous laser ablation (EVLA) Int J Surg. 2012;10(3):134–139. doi: 10.1016/j.ijsu.2012.02.013. [DOI] [PubMed] [Google Scholar]
  • 11.Araujo WJ, Timi JR, Nejm CS, Jr, Caron FC. Evaluation of great saphenous vein occlusion rate and clinical outcome in patients undergoing laser thermal ablation with a 1470-nm bare fiber laser with low linear endovenous energy density. J Vasc Bras. 2015;14(4):282–289. doi: 10.1590/1677-5449.004015. [DOI] [Google Scholar]
  • 12.França LH, Tavares V. Insuficiência venosa crônica: uma atualização. J Vasc Bras. 2003;2(4):318–328. [Google Scholar]
  • 13.Beebe-Dimmer JL, Pfeifer JR, Engle JS, Schottenfeld D. The epidemiology of chronic venous insufficiency and varicose veins. Ann Epidemiol. 2005;15(3):175–184. doi: 10.1016/j.annepidem.2004.05.015. [DOI] [PubMed] [Google Scholar]
  • 14.Scott TE, LaMorte WW, Gorin DR, Menzoian JO. Risk factors for chronic venous insufficiency: a dual case-control study. J Vasc Surg. 1995;22(5):622–628. doi: 10.1016/S0741-5214(95)70050-1. [DOI] [PubMed] [Google Scholar]
  • 15.Araujo WJ, Erzinger FL, Caron FC, Nejm CS, Jr, Timi JR. Influência da termoablação com baixa e alta densidade de energia na junção safeno-femoral, utilizando laser endovenoso 1470 nm. J Vasc Bras. 2017;16(3):220–226. doi: 10.1590/1677-5449.010916. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Kane K, Fisher T, Bennett M, et al. The incidence and outcome of endothermal heat-induced thrombosis after endovenous laser ablation. Ann Vasc Surg. 2014;28(7):1744–1750. doi: 10.1016/j.avsg.2014.05.005. [DOI] [PubMed] [Google Scholar]
  • 17.Vuylsteke ME, Mordon SR. Endovenous laser ablation: a review of mechanisms of action. Ann Vasc Surg. 2012;26(3):424–433. doi: 10.1016/j.avsg.2011.05.037. [DOI] [PubMed] [Google Scholar]
  • 18.Cassou MF, Gonçalves PC, Engelhorn CA. Probabilidade de refluxo nas veias safenas de mulheres com diferentes graus de insuficiência venosa crônica. J Vasc Bras. 2007;6(3):238–245. doi: 10.1590/S1677-54492007000300007. [DOI] [Google Scholar]
  • 19.van der Geld CW, van den Bos RR, van Ruijven PW, Nijsten T, Neumann HA, van Gemert MJ. The heat-pipe resembling action of boiling bubbles in endovenous laser ablation. Lasers Med Sci. 2010;25(6):907–909. doi: 10.1007/s10103-010-0780-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Proebstle TM, Krummenauer F, Gül D, Knop J. Nonocclusion and early reopening of the great saphenous vein after endovenous laser treatment is fluence dependent. Dermatol Surg. 2004;30(2 Pt 1):174–178. doi: 10.1111/j.1524-4725.2004.30051.x. [DOI] [PubMed] [Google Scholar]
  • 21.Kabnick LS. Outcome of different endovenous laser wavelengths for great saphenous vein ablation. J Vasc Surg. 2006;43(1):88–93. doi: 10.1016/j.jvs.2005.09.033. [DOI] [PubMed] [Google Scholar]
  • 22.Theivacumar NS, Dellagrammaticas D, Beale RJ, Mavor AI, Gough MJ. Factors influencing the effectiveness of endovenous laser ablation (EVLA) in the treatment of great saphenous vein reflux. Eur J Vasc Endovasc Surg. 2008;35(1):119–123. doi: 10.1016/j.ejvs.2007.08.010. [DOI] [PubMed] [Google Scholar]
J Vasc Bras. 2019 Aug 29;18:e20190009. [Article in Portuguese]

Influência da densidade de energia endovenosa linear no sucesso da termoablação endovenosa a laser como tratamento da insuficiência venosa crônica

Luiza de Freitas Heineberg 1, Adriana Buechner de Freitas Brandão 1,2,, Filipe Carlos Caron 2, Jaqueline Beirith 1, Walter Junior Boim de Araujo 2

Resumo

Contexto

Mostra-se relevante a elucidação da influência da densidade de energia endovenosa linear (linear endovenous energy density, LEED) média no sucesso do tratamento da insuficiência venosa crônica por termoablação endovenosa a laser visando diminuir a morbidade desse método.

Objetivos

Avaliar a influência da LEED média na prevalência de fechamento das safenas após 30 dias do procedimento.

Métodos

Foram analisados 153 membros inferiores de 118 pacientes de um hospital referência, submetidos a termoablação com laser endovenoso 1470 nm sob anestesia local para o tratamento de insuficiência venosa crônica. Foi calculada a LEED média dos pacientes tratados para determinar se foi necessária uma energia maior que a média para o sucesso do tratamento.

Resultados

Dos 153 membros inferiores submetidos ao tratamento, houve diferença significativa (p = 0,021) no fechamento da junção safeno-femoral relacionada à LEED média utilizada acima do joelho. Por outro lado, no segmento de coxa não houve diferença significativa.

Conclusões

A LEED acima da média de 70,57 J/cm apresentou um índice maior de fechamento na junção safeno-femoral. Porém, no segmento de coxa, a densidade não influenciou o resultado, demonstrando que uma energia mais alta do que 70,57 J/cm tende a não ser necessária para o tratamento desse segmento.

Palavras-chave: insuficiência venosa, laser, veia safena, varizes

INTRODUÇÃO

A insuficiência venosa crônica (IVC) é uma doença comum no consultório do cirurgião vascular e ocorre em 25 a 33% das mulheres e em 10 a 20% dos homens na população adulta ocidental1. Está diretamente relacionada ao absenteísmo laboral e a gastos do sistema público de saúde2. Diante dessa importância socioeconômica, o estudo de novas técnicas que possam viabilizar o tratamento efetivo com melhores resultados tem sido cada vez mais valorizado, principalmente em relação ao índice de recidivas, a complicações e ao retorno precoce às atividades diárias3.

O tratamento da IVC compreende: medidas clínicas e mudança de hábitos de vida; escleroterapia com espuma e cirurgia de varizes através da técnica de mini-incisões; safenectomia por fleboextração; e métodos endoluminais como radiofrequência e termoablação a laser (endovenous laser ablation, EVLA)4 - 7.

As técnicas minimamente invasivas são alternativas ao tratamento convencional cirúrgico de stripping da veia safena magna (VSM) e vêm ganhando espaço na medicina5 , 6. Entre elas destaca-se a EVLA, com resultados favoráveis no que diz respeito ao índice de fechamento das safenas, à satisfação do paciente e à menor morbidade pós-procedimento3 , 8 , 9.

Diante da crescente valorização da EVLA como um método alternativo ao stripping para o tratamento da IVC10, este estudo foi desenvolvido com a intenção de elucidar qual a influência da densidade de energia endovenosa linear (linear endovenous energy density, LEED) no desfecho do procedimento após 30 dias.

MÉTODOS

Trata-se de um estudo retrospectivo que avaliou prontuários de 193 pacientes com IVC de um hospital referência, submetidos a EVLA e reavaliados após 30 dias. O projeto foi aprovado pelo Comitê de Ética da nossa instituição, sob o registro nº 80030817.0.00005580 na Plataforma Brasil.

Os critérios de inclusão foram pacientes com IVC submetidos a EVLA desde a junção safenofemoral (JSF) até o joelho no HAC de 2011 até fevereiro de 2018. Já os critérios de exclusão foram: pacientes que não retornaram em 30 dias; pacientes com doença arterial periférica, síndromes de hipercoagulação grave e história de trombose venosa profunda ou de insuficiência venosa profunda; e pacientes com prontuários incompletos.

Foram então analisados 153 membros inferiores de 118 pacientes submetidos ao tratamento com EVLA para IVC. O procedimento iniciava-se com o paciente em decúbito dorsal. Era realizado um botão anestésico no local da punção e procedia-se com punção ecoguiada da VSM com Abocath®16, preferencialmente em um ponto distal à última veia tributária com refluxo, seguida de instalação de introdutor valvulado 6F. A seguir, a fibra ótica (radial ou linear) era introduzida e conectada a um gerador de energia a laser endovenoso com comprimento de onda padrão de 1470 nm e registrado na Agência Nacional da Vigilância Sanitária (80058580018).

Uma vez certificada a posição endoluminal na VSM a 2,5 cm distal à JSF, fazia-se a indução anestésica local tumescente ao longo de todo o percurso da VSM a ser tratada. Utilizava-se seringa ou bomba de infusão mecânica, com uma solução formada por 250 mL de soro fisiológico a 0,9% para 20 mL de lidocaína a 2% e adrenalina 1:100.000 com 4 mL de bicarbonato de sódio a 8,4% (Figura 1). Uma vez finalizada a anestesia, conferia-se novamente a posição da fibra a 2,5 cm da junção e iniciava-se o disparo do laser (Figura 2). A fibra era tracionada manualmente, de forma contínua, em direção caudal até o limite distal da safena a ser tratada11.

Figura 1. Início da indução anestésica intumescente com controle ecográfico.

Figura 1

Figura 2. Confirmação do posicionamento da fibra através de transiluminação (A) e controle ecográfico (B).

Figura 2

Após o procedimento, realizava-se curativo com compressão extrínseca no trajeto da VSM com chumaço de algodão e meia elástica 7/8 de alta compressão (30-40 mmHg). A alta hospitalar se dava no mesmo dia, depois de aproximadamente 2 horas de observação após o término da cirurgia, com prescrição de analgésicos e anti-inflamatórios não esteroidais por 5 dias. A meia elástica era mantida por 48 horas e retirada pelo próprio paciente. A partir do terceiro dia, o paciente vestia as meias durante o dia e as retirava durante o banho e para dormir. Embora não houvesse restrição à deambulação, recomendava-se cerca de 40 minutos de repouso com pernas elevadas a cada hora.

Os pacientes foram reavaliados aos 7 e 30 dias após a cirurgia através de exame físico e ecografia vascular com Doppler (Figura 3). Entre os fatores analisados destacam-se: presença ou ausência de parestesia, flebite e trombose venosa profunda no membro inferior tratado, assim como taxa de obliteração da VSM e ausência de refluxo.

Figura 3. Controle ecográfico realizado no 7º dia pós-operatório demonstrando ausência de fluxo na veia safena.

Figura 3

A avaliação ecográfica da JSF quanto a obliteração e refluxo seguiu as recomendações das diretrizes de prática clínica para pacientes com varizes e doenças venosas da Society for Vascular Surgery e da American Venous Forum. Considerou-se resultado positivo a ausência de coto pérvio e de refluxo. Além disso, os pacientes foram divididos em ausência de coto pérvio, coto parcialmente pérvio e presença de refluxo (Tabela 1).

Tabela 1. Classificação dos resultados do eco-Doppler na junção safenofemoral após a termoablação.

Patência J0 Ausência de coto pérvio
J1, J2, J3, J4, etc. Junção com coto pérvio de 1, 2, 3, 4 cm, etc.
Refluxo R+ Refluxo
R- Sem refluxo

Análise estatística

Os dados dos prontuários foram coletados e armazenados em uma planilha do Microsoft Excel. A análise de dados foi realizada com o auxílio do programa computacional SPSS, versão 22.0.

Os resultados foram expressos através de estatística descritiva. A análise inferencial foi realizada por meio do teste qui-quadrado de Pearson, teste exato de Fisher, teste t de Student para as variáveis paramétricas e teste de Mann-Whitney para as variáveis não paramétricas. Os valores de p menores que 0,05 foram considerados significativos.

RESULTADOS

Dos 193 prontuários analisados, 118 foram selecionados para análise e 153 membros inferiores foram avaliados. A maioria da população do estudo era do sexo feminino (55,9%) e apresentava sobrepeso [índice de massa corporal (IMC) médio de 29,67], e a idade média foi de 55,35 anos. Foi utilizada fibra radial dois anéis em 66,8% e linear em 33,2% dos pacientes, todas com 600 µ de diâmetro e potência de 6 watts. Os dados descritivos são apresentados abaixo em forma de tabelas referentes à idade e ao IMC (Tabela 2), ao sexo (Tabela 3) e a complicações (Tabela 4).

Tabela 2. Dados descritivos referentes à idade e ao IMC.

Análise estatística Idade (anos) IMC (kg/m2)
n 118 118
Média 52,35 29,67
Desvio padrão 11,74 5,57

IMC, índice de massa corporal.

Tabela 3. Dados descritivos referentes ao sexo.

Sexo Frequência Porcentagem
Feminino 66 55,9
Masculino 52 44,1
Total 118 100,0

Tabela 4. Dados descritivos referentes à frequência de complicações após o procedimento nos 118 pacientes.

Complicação Frequência Porcentagem
TVP 1 0,8
Parestesia 31 26,3
Flebite 16 13,5

TVP, trombose venosa profunda.

Houve diferença significativa entre os grupos (ausência de coto pérvio, coto parcialmente pérvio e presença de refluxo) com relação à LEED média aplicada, segundo a análise de variância (ANOVA), com p = 0,021 (Tabela 5). O pós-teste de Bonferroni mostra que houve diferença significativa quando comparados os grupos que apresentaram ausência de coto pérvio e presença de refluxo (p = 0,017), assim como quando comparados os grupos que apresentaram coto parcialmente pérvio e presença de refluxo (p = 0,032) (Tabela 6).

Tabela 5. Resultados do teste ANOVA quanto à relação entre a LEED aplicada e o fechamento da VSM na JSF.

População Soma dos quadrados df Quadrado médio Z p
Entre grupos 1453,727 2 726,863 3,978 0,021
Nos grupos 27409,025 150 182,727
Total 28862,751 152

ANOVA, análise de variância; df, graus de liberdade; JSF, junção safenofemoral; LEED, linear endovenous energy density; VSM, veia safena magna.

Tabela 6. Valores médios e desvio padrão da LEED para os grupos que apresentaram ausência de coto pérvio, coto parcialmente pérvio e presença de refluxo na JSF.

Referência anatômica n Média (J/cm) Desvio padrão (J/cm)
Ausência de coto pérvio 41 72,59b 12,18
Coto parcialmente pérvio 109 70,38b 12,71
Presença de refluxo 3 49,90a 44,80
Total 153 70,57 13,77

JSF, junção safenofemoral; LEED, linear endovenous energy density; Letras diferentes indicam resultados com diferença significativa pelo teste de Bonferroni.

Em relação ao tipo de fibra utilizado e ao LEED aplicado, houve uma tendência de diferença significativa, segundo o teste de Levine, com p = 0,084. Conforme o teste, para a fibra linear foi necessária uma LEED média mais alta, de 73,30, enquanto na fibra radial a LEED média foi de 69,21. Quando comparados o fechamento das safenas e a presença de refluxo com o tipo de fibra utilizada, não houve diferença significativa (p = 0,174), de acordo com o teste qui-quadrado aplicado.

DISCUSSÃO

A IVC pode ser definida como uma alteração do sistema venoso superficial e/ou profundo. A prevalência da doença tem crescido mundialmente e aumenta com a idade. Um estudo feito com uma população de Botucatu, no estado de São Paulo, apontou uma prevalência de varizes de 35,5%12 - 14.

Atualmente, existe um direcionamento dos estudos relacionados ao EVLA em busca de formas mais seguras de utilizá-lo com menos efeitos adversos. Para isso, levam-se em conta dados como o comprimento de onda e a energia utilizada, a velocidade com que se aplica o laser e os diferentes tipos de fibras ópticas10.

A liberação do laser a partir de um gerador levará a uma reação térmica em que a energia do laser é entregue e captada pela água intracelular das células endoteliais da safena. Esse mecanismo de ação pode ser regulado através de parâmetros físicos, tais como comprimento de onda, tipo de administração de energia e quantidade de energia por área de superfície15 , 16.

O nível de energia que será absorvido é de extrema importância, uma vez que a retração do vaso só ocorre quando se atingir um determinado patamar; caso contrário, a veia poderá manter-se aberta ou recanalizar17 - 19. Por outro lado, um excesso de energia poderá lesionar os tecidos adjacentes, como nervos e vasos linfáticos. A LEED é uma das variáveis mais marcantes durante o procedimento, e alguns estudos correlacionam a densidade de energia a resultados favoráveis ou desfavoráveis13 , 20 - 22.

O termo LEED começou a ser utilizado em 2005 e tornou-se referência no cálculo da energia utilizada no procedimento devido à sua facilidade e possível padronização. A fórmula que o compõe leva em conta a potência e a velocidade de tração com que se traciona a fibra óptica12.

Nos membros inferiores avaliados neste estudo, a LEED média foi de 70,57 J/cm, e observou-se que, para se obter uma termoablação efetiva na JSF, foi necessária uma LEED acima dessa média. A alta energia proporcionou a obliteração parcialmente completa ou completa na JSF e a ausência de refluxo, resultados também encontrados por Proebstle et al.17.

CONCLUSÃO

Em 30 dias de seguimento dos pacientes submetidos a EVLA sob anestesia local para tratamento de IVC, mostrou-se que a utilização de uma LEED acima da média de 70,57 J/cm na JSF teve melhores resultados, com índices maiores de obliteração e ausência de refluxo, em relação a uma LEED menor. No segmento de coxa, não houve diferença significativa. Isso leva à conclusão de que, nesse segmento, não é necessária uma energia mais elevada para que se obtenha o resultado desejado, sendo possível, portanto, utilizar uma LEED mais baixa para diminuir a chance de complicações.

Apesar de os resultados serem compatíveis com a literatura, são necessários mais estudos com dados específicos sobre a LEED aplicada na JSF e no segmento de coxa, assim como a sua relação com a incidência de parestesia.

Footnotes

Como citar: Heineberg LF, Brandão ABF, Caron FC, Beirith J, Araujo WJB. Influência da densidade de energia endovenosa linear no sucesso da termoablação endovenosa a laser como tratamento da insuficiência venosa crônica. J Vasc Bras. 2019;18:e20190009. https://doi.org/10.1590/1677-5449.190009

Fonte de financiamento: Nenhuma.

O estudo foi realizado no Hospital Angelina Caron e Faculdades Pequeno Príncipe, Curitiba, PR, Brasil.


Articles from Jornal Vascular Brasileiro are provided here courtesy of Sociedade Brasileira de Angiologia e Cirurgia Vascular

RESOURCES