Abstract

There is substantial evidence indicating that double-row (DR) repair restores more of the anatomic rotator cuff footprint and is biomechanically superior to single-row (SR) repair. Transosseous-equivalent (TOE) techniques have shown biomechanical advantages when compared with traditional DR, including increased contact at the rotator cuff footprint, higher pressure at the tendon-bone interface, and increased failure strength. Several meta-analyses of evidence level 1 and 2 studies have shown a lower rate of failed/incomplete healing when DR repair was compared with SR repair types. There is some limited evidence that TOE techniques improve healing rates in large and massive tears as compared with SR and DR. Overall, most level 1 and 2 studies have failed to prove a significant difference between SR and DR repairs in terms of clinical outcomes. However, most studies include only short-term follow-up, minimizing the impact that the higher rate of retears/failed healing seen with SR repairs can have in the long term. There are no high-quality clinical studies comparing different DR configurations, and there are currently not enough clinical data to determine the functional advantages of various DR technique modifications over one another. Although numerous biomechanical and clinical studies comparing different rotator cuff repair techniques have been published in the past decade, none has achieved universal acceptance. It is essential for the orthopaedic surgeon to know in detail the available literature to be able to apply the most appropriate and cost-effective technique in terms of healing and functional outcomes. This review provides a critical analysis of the comparative biomechanical and clinical studies among SR, DR, and TOE techniques reported in the literature in the past decade.

Keywords: rotator cuff repair, single row- double row, transosseous equivalent, biomechanical, structural outcomes, functional


The number of rotator cuff repairs has increased steadily in the past 2 decades.20 Good to excellent outcomes have been reported in the short- and long-term follow-up in most cases.11,12,45,50 However, despite advances in instrumentation and surgical techniques, a risk of rerupture of 20% to 60% has been observed.10,14 Although patients whose tendons fail to heal can still have pain relief, most studies have shown that patients with healed repairs achieve higher patient-reported outcome scores.14,57

Biomechanical studies of double-row (DR) repair have shown increased load to failure, improved contact areas and pressures, and decreased gap formation at the healing enthesis as compared with single-row (SR) repair.18,54 However, many clinical studies have not yet demonstrated a substantial improvement over SR repair with regard to either the degree of structural healing or functional outcomes.20,34,50,58 The transosseous-equivalent technique (TOE; also called “suture bridge”) was designed to improve the biomechanical repair construct in an effort to improve some limitations of conventional SR and DR repairs.39 In the TOE repair, the suture limbs from the medial row of anchors are brought over the bursal side of the rotator cuff and secured to the lateral margin of the greater tuberosity footprint with a knotless anchor.39

Although numerous biomechanical and clinical studies comparing different rotator cuff repair techniques have been published in the past decade, none has achieved universal acceptance.18,20 It is essential for the orthopaedic surgeon to know in detail the available literature to be able to apply the most appropriate and cost-effective technique in terms of healing and functional outcomes. Therefore, the purpose of this review is to provide a critical analysis of the comparative biomechanical and clinical studies among SR, DR, and TOE techniques reported in the literature in the past decade.

Biomechanical Studies

Single Row vs Double Row

After a rotator cuff repair, the structure and composition of the native tendon-bone interface are not re-formed during healing, resulting in a mechanically and structurally inferior interface.1,55 The repaired tendon forms fibrovascular scar tissue with a large proportion of type III collagen rather than the biomechanically superior type I collagen.1,55 In particular, the zone of calcified cartilage does not re-form, and this scar tissue is biomechanically weaker and more prone to failure than the native insertion.1,55 Therefore, to achieve an effective repair, it is essential to enhance the biomechanical conditions for healing. The ideal rotator cuff repair should provide the following: restoration of the footprint contact area, appropriate compression of the tendon on the footprint, and minimal motion at the bone-tendon interface until durable tendon-bone healing is completed.13,28,36

Meier and Meier30 used 3-dimensional mapping to determine the area of footprint re-creation with different repair techniques: transosseous simple suture, SR suture anchor, and DR suture anchor. DR fixation consistently reproduced 100% of the original supraspinatus footprint, whereas the SR suture anchor fixation and transosseous simple suture techniques reproduced only 46% and 71% of the insertion site, respectively. Brady et al5 also demonstrated that after an isolated lateral-row repair, 52.7% of the rotator cuff footprint remained uncovered. Park et al40,42 showed in several cadaveric studies that SR repairs consistently produced less pressurized contact area at the site of repair compared with DR techniques.

In addition to a wider contact area, most biomechanical studies have shown that DR repair has superior time-zero structural properties in rotator cuff repair.18 Smith et al49 found that the DR technique demonstrated superior resistance to gap formation under static loading as compared with the SR technique. Kim et al24 found that DR repair improved initial strength and stiffness and decreased gap formation and strain over the footprint when compared with an SR repair. In a human cadaveric study, Meier and Meier29 demonstrated that fixation strength of the DR technique was significantly greater than that of SR suture anchor technique. In a biomechanical study, Milano et al32 compared the mechanical behavior of SR and DR rotator cuff repair with suture anchors under a cyclic loading test. They reported that the DR technique was significantly more resistant to cyclic displacement than the SR technique, not only in repairs that were tension-free but also in those that were under tension.

Double-Row vs Transosseous-Equivalent Repairs

The biomechanical advantages of DR repairs over SR repairs have not been consistently reproduced in the clinical setting.20,34,50 TOE repairs were developed to address this deficiency.39,40,42 The theoretical advantages of the TOE technique over the conventional DR repair are as follows: (1) maximization of the pressurized contact area; (2) decreased tendon strangulation (because the lateral tendon is not penetrated); (3) preserved vascularity over the lateral tissue (owing to the absence of lateral knots); (4) avoidance of anchor overcrowding at the repair site by placing the second fixation row 1 cm lateral to the tuberosity footprint; (5) interconnection of the anchors, resulting in better load sharing and less tension mismatch on a given anchor with rotation; and (6) prevention of synovial fluid access to the rotator cuff footprint.35,3842 Park et al41 showed that the ultimate load-to-failure value was significantly higher following knotted TOE repair than following DR repair. In addition, the knotted TOE technique provided significantly more pressurized contact area and overall pressure.38 Hatta et al16 showed that the knotless TOE technique for medium- to large-sized tears provided a more uniform stiffness distribution across the repaired supraspinatus muscles as compared with the DR technique.

TOE repairs can be performed with various suture configurations but are generally divided between those in which the medial row is tied and all-knotless repairs. Some studies have shown that the musculotendinous junction is the primary failure point for DR and knotted TOE repairs.9,22 This has led to the development of knotless (“speed bridge”) techniques.53 The latest techniques use flattened tape sutures (rather than conventional sutures) to better distribute compressive forces on the cuff tendons, improve tissue cut-through resistance, enhance self-reinforcement, and possibly better preserve vascular flow.2,7

Controversy exists regarding the contribution of the medial row knots to biomechanical properties in DR repair. On one hand, some authors have suggested that the medial row knots reduce the failure load by preventing gap formation and absorbing the energy. On a porcine cadaveric shoulder model, Pauly et al43 showed that medial mattress knots increase initial biomechanical stability. In a human cadaveric study, Busfield et al8 randomized 6 matched pairs of shoulders to receive a TOE repair with or without medial knots. They demonstrated less gap formation and higher failure strengths with the knotted configuration. Nassos et al,35 in a human cadaveric study, showed that a TOE technique with medial knots better prevented synovial fluid leakage onto the rotator cuff footprint as compared with knotless repairs. They proposed that isolating the healing zone interface from the synovial fluid could improve healing rates. On the other hand, other authors have failed to prove any advantage of the knotted TOE as compared with the knotless TOE. Spang et al51 found the knotless TOE technique biomechanically similar to the conventional TOE in an ovine cadaveric study. In a human cadaveric study, Burkhart et al7 showed that DR footprint reconstruction with a knotless TOE system produced ultimate loads and cyclic displacements that were statistically equivalent to those of standard TOE reconstructions. In a recent biomechanical study, Tashjian et al52 compared the biomechanics of (1) a TOE repair with medial and lateral anchors with tape and (2) a TOE knotless tape repair with only laterally placed intraosseous anchors. They found that the TOE knotless construct with 2 lateral anchors was equivalent in biomechanical function to a traditional 4-anchor construct, reducing anchor load in the tuberosity.

Functional Outcomes and Healing Rates

Single Row vs Double Row

Several overlapping meta-analyses of evidence level 1 and 2 studies comparing functional outcomes and healing rates after SR and DR arthroscopic rotator cuff repairs have been published over the past decade, with conflicting results (Table 1). Perser et al44 included three level 1 and two level 2 studies with 303 patients and a mean follow-up of 20 months. The authors concluded that DR rotator cuff repair did not show a statistically significant improvement in clinical outcome with short-term follow-up. They were unable to analyze healing results owing to the lack of details in the studies. Prasathaporn et al46 analyzed the same studies as Perser et al. The authors found no significant difference in clinical outcomes. However, DR repair showed a significantly higher rate of tendon healing and greater external rotation. Sheibani-Rad et al48 performed a systematic meta-analysis of five level 1 studies comparing SR and DR rotator cuff repairs with 349 patients and a mean follow-up of 21 months. They found no significant differences in clinical outcomes between SR and DR. Owing to incomplete data, the rate of retears was not evaluated. Zhang et al59 analyzed six level 1 and two level 2 studies with 619 patients with a minimum follow-up of 24 months. The authors were the first to perform a subgroup analysis according to rotator cuff tear size (tears <3 cm and ≥3 cm). The authors concluded that the DR fixation technique increased postoperative rotator cuff integrity and improved the clinical outcomes for full-thickness rotator cuff tears >3 cm. Xu et al56 included five level 1 and four level 2 studies with 651 patients and a mean follow-up of 23 months. There was a statistically significant difference in favor of DR repair for overall American Shoulder and Elbow Surgeons (ASES) score and internal rotation range of motion. Additionally, for tears >3 cm, DR techniques produced better outcomes (ASES and University of California, Los Angeles [UCLA]) than SR techniques. Regarding retears, the pooled results showed an incidence of 23.8% in the DR repair group and 40.2% in the SR repair group (risk ratio, 0.59; 95% CI, 0.41-0.86), which was a statistically significant difference.

TABLE 1.

Summary of Meta-analysis of Level 1 and 2 Studies Comparing Single- and Double-Row Rotator Cuff Repaira

First Author Year Journal Studies, n Patients, n Level of Evidence Follow-up, Mean (Range), mo Functional Outcomes Retears
Perser44 2011 Sports Health 5 303 1 and 2 23 (12-40) Scores: NSD (Constant-Murley, ASES, UCLA, WORC, DASH)
ROM: NR
Strength: NR
Overall: NSD
Prasathaporn46 2011 Arthroscopy 5 308 1 and 2 23 (12-40) Scores: NSD (ASES, UCLA, WORC, DASH)
ROM: Significantly more ER with DR
Strength: NR
Overall: significantly > tendon retears with SR
Sheibani-Rad48 2013 Arthroscopy 5 349 1 21 (12-44) Scores: NSD (ASES, Constant-Murley, UCLA) ROM: NR
Strength: NR
NR
Zhang59 2013 PloS One 8 619 1 and 2 26 (24-34) Scores: tears <3 cm: NSD (ASES, Constant-Murley, UCLA); tears >3 cm: ASES and UCLA significantly > in DR
ROM: NR
Strength: NR
Overall: significantly > with SR
Partial: significantly < with DR
Complete: NSD between SR and DR
Xu56 2014 J Shoulder Elbow Surg 9 651 1 and 2 23 (12-42) Scores: tears <3 cm: NSD (ASES, Constant-Murley, UCLA); tears >3 cm: ASES and UCLA significantly > in DR
ROM: Significantly more IR with DR
Strength: NR
Overall: significantly > with SR
Millett34 2014 J Shoulder Elbow Surg 7 567 1 21 (12-32) Scores: tears <3 cm: NSD (ASES, Constant-Murley, UCLA); tears >3 cm: ASES and UCLA significantly > in DR
ROM: NR
Strength: NR
Overall: significantly > with SR
Ying58 2014 Orthop Surg 11 807 1 and 2 24 (12-36) Scores: NSD (ASES, Constant-Murley, UCLA)
ROM: NSD
Strength: NR
Overall: significantly > with SR
Partial: significantly < with DR
Complete: NSD between SR and DR
Sobhy50 2018 Eur J Orthop Surg Traumatol 7 477 1 21 (12-32) Scores: NSD (Constant-Murley, ASES, WORC, SANE)
ROM: NR
Strength: NR
Overall: significantly > with SR
Partial: significantly < with DR
Complete: NSD between SR and DR

aASES, American Shoulder and Elbow Surgeons; DASH, Disabilities of the Arm, Shoulder and Hand; DR, double row; IR, internal rotation; NR, not reported; NSD, no significant difference; ROM, range of motion; SANE, Single Assessment Numerical Evaluation; SR, single row; UCLA, University of California, Los Angeles; WORC, Western Ontario Rotator Cuff Index.

In other reviews, Millett et al34 included only level 1 studies in their meta-analysis—specifically, 7 studies with 567 patients and a mean follow-up of 21 months. SR repairs resulted in significantly higher retear rates when compared with DR repairs, especially with regard to partial-thickness retears. The overall retear rate was 25.9% in the SR group and 14.2% in the DR group. There was a statistically significantly increased risk of sustaining an imaging-proven retear of any type in the SR group (relative risk, 1.76; 95% CI, 1.25-2.48; P = .001). However, there were no detectable differences in improvement in outcome scores between the techniques. Ying et al58 included seven level 1 studies and four level 2 studies with 807 patients and a mean follow-up of 25 months. The authors concluded that given the paucity of high-quality evidence and the poor methodological quality of the included studies, no definite conclusion could be drawn about differences in overall outcomes of DR and SR techniques. In 2018, Sobhy et al50 performed a meta-analysis of all available level 1 prospective randomized controlled trials comparing SR and DR repairs. They included 7 studies with 477 patients. Within the domain of level 1 mid- and short-term studies, DR repair showed significantly better UCLA scores only. Overall retear rate was significantly lower in the DR group. The authors also reported stratified healing rates into partial and complete retears. Full-thickness retear incidence showed no significant difference between groups. However, the partial-thickness retear rate was significantly lower in the DR group—specifically, 10.3% in the DR group and 23.4% in the SR group (P = .009).

Very few studies have compared different DR repair techniques (Table 2). Kim et al25 compared conventional DR repair with the TOE technique among tears sized 1 to 4 cm. The authors found no difference in terms of functional outcomes and retear rates between these techniques at the end of 2 years of follow-up. Park et al37 compared 174 patients—55 with the conventional DR repair and 119 with the knot-tying TOE repair—for medium- to large-sized rotator cuff tears. At a mean follow-up of 25 months, no significant differences were found between the groups in either the functional results or the rerupture rate. Lee et al27 retrospectively compared the clinical and radiologic outcomes of patients who underwent arthroscopic rotator cuff repairs by the TOE (n = 37) and DR modified Mason-Allen (n = 39) techniques. The patients who underwent DR modified Mason-Allen repair had comparable shoulder functional outcomes and a comparable retear rate with those who underwent TOE repairs. Hashiguchi et al15 compared clinical outcomes and retear rate between 52 patients who underwent arthroscopic DR and 63 who underwent knotted TOE repair for medium-sized rotator cuff tears. There was no significant difference in Constant score between the groups. Postoperative MRI revealed that retear rate in the knotted TOE group was significantly lower than the DR group. This was the first study to find a significant difference in healing rates between conventional DR repair and TOE.

TABLE 2.

Summary of Studies Comparing Double-Row Rotator Cuff Repair Techniquesa

First Author Year Journal Patients or Shoulders, n Level of Evidence Follow-up, Mean ± SD (Range), mo Repair Technique Functional Outcomes Retears
Kim25 2012 Am J Sports Med 52 2 37 (24-54) DR: 26. Knot-tying TOE: 26 NSD (UCLA, ASES, Constant-Murley) NSD in retears
Rhee47 2012 Am J Sports Med 110 2 21 (12-34) Knotless TOE: 51. Knot-tying TOE: 59
NSD (UCLA, Constant-Murley) Retears significantly < in knotless TOE. Knot-tying TOE significantly > retears at the musculotendinous junction
Boyer4 2015 Knee Surg Sports Traumatol Arthrosc 73 3 29 (23-32) Knot-tying TOE: 38. Knotless TOE: 35
NSD (Constant-Murley, ROM, strength) NSD in retears
Park37 2013 Arch Orthop Trauma Surg 169 3 25 (24-40) DR: 50. Knot-tying TOE: 119 NSD (ASES, VAS, Constant-Murley, strength) NR
Hug19 2015 Knee Surg Sports Traumatol Arthrosc 40 4 24 ± 4.7 Knot-tying TOE: 20. Knotless TOE: 20 NSD (WORC, SSV, Constant-Murley) NSD in retears
Millet33 2017 Arch Orthop Trauma Surg 137 3 33 (24-64) Knotless TOE: 114. Knot-tying TOE: 41 NSD (ASES, SF-12) Retears significantly < in knotless TOE
Lee27 2018 J Shoulder Elbow Surg 76 3 TOE: 36 ± 7. DR: 34 ± 7 Knot-tying TOE: 37. DR: 39 NSD (VAS, UCLA, ASES, Constant-Murley, ROM) NSD in retears
Kim26 2018 J Orthop Surg Res 100 2 24
Knotless TOE: 114. Knot-tying TOE: 41 NSD (UCLA, ASES, Constant-Murley, VAS) NSD in retears
Hashiguchi15 2018 J Orthop 115 4 37 (24-88) Knot-tying TOE: 37. DR: 39 NSD (Constant-Murley) Retears significantly < in knot-tying TOE

aASES, American Shoulder and Elbow Surgeons; DR, double row; NR, not reported; NSD, no significant difference; ROM, range of motion; SF-12, 12-Item Short Form Health Survey; SSV, Subjective Shoulder Value; TOE, transosseous equivalent; UCLA, University of California, Los Angeles; VAS, visual analog scale; WORC, Western Ontario Rotator Cuff Index.

Only a few clinical studies have compared different TOE techniques. Rhee et al47 compared the clinical results and repair integrity of arthroscopic rotator cuff repair between a knotless TOE (51 shoulders) and a conventional knot-tying TOE (59 shoulders) for patients with medium-sized full-thickness rotator cuff tears. The authors found no significant difference in functional outcomes between the groups. However, the knotless group had a significantly lower retear rate when compared with the conventional knot-tying group. Moreover, retears occurred at the musculotendinous junction in 72.7% of patients in the knotted group, while no medial cuff failure occurred with the knotless technique. Boyer et al4 also compared the clinical results and repair integrity of arthroscopic rotator cuff repair between a knotless TOE (35 shoulders) and a conventional knot-tying TOE (38 shoulders). At a mean follow-up of 29 months, no significant differences were found between the groups in either the functional results or the retear rate. Hug et al19 reported the results of a consecutive treatment cohort (knotted TOE vs knotless tape bridging) and found no significant differences in functional outcome scores and retears between treatment groups at the 2-year follow-up. Millett et al33 compared the clinical results and repair integrity of arthroscopic rotator cuff repair between a knotless TOE (102 shoulders) and a conventional knot-tying TOE (35 shoulders) for patients with full-thickness rotator cuff tears. The authors found no significant differences in clinical outcomes between groups at a mean follow-up of 3 years. However, patients with a knotted medial row were significantly more likely to have an MRI-diagnosed full-thickness rotator cuff retear. Kim et al26 prospectively evaluated 100 consecutive patients with full-thickness rotator cuff tears treated with the arthroscopic conventional (n = 50) or knotless (n = 50) TOE technique. The knotless TOE technique showed comparable functional outcomes and retears rates with those of conventional knotted TOE techniques in medium to large full-thickness rotator cuff tears at short-term follow-up.

Discussion

From a biomechanical point of view, most studies favored DR repair as compared with SR repair with regard to tensile strength, construct failure, gap formation, and footprint coverage.18,20 With regard to comparative biomechanical studies for different DR configurations, TOE techniques have shown some promising features when compared with conventional DR configurations, which could have a positive impact in tendon healing. Nevertheless, biomechanical studies comparing different TOE techniques are scarce and still controversial. More comparative biomechanical studies are needed to better define if the benefit of additional construct strength observed with knotted TOE techniques may be lost without tying of medial row sutures.

General consideration of all the included meta-analyses shows significant improvement in overall functional outcomes for both DR and SR repairs as compared with preoperative values.34,44,46,48,50,56,58,59 Moreover, 3 meta-analyses found that in comparison with SR repairs, DR repairs had better functional scores or increased range of motion overall and especially for tears measuring >3 cm.56,58,59 Despite the innovations and documented benefits in the laboratory setting, postoperative functional outcomes with newer TOE techniques, at short- to medium-term follow-up, have been equivocal. From the 9 evaluated studies comparing different DR configurations, none of the techniques showed a significant superiority over the others regarding clinical outcomes (Table 2).

The relation between clinical outcomes and retears is controversial. Overall, although a significant increase in imaging-diagnosed retear rates after SR repair was demonstrated, this difference did not always correlate with inferior outcome scores. However, it is important to highlight that most retears of the included meta-analyses comparing SR and DR were partial thickness, and most had a short mean follow-up (range, 21-26 months), with a maximum follow-up of only 44 months (Table 1). Keener et al23 prospectively evaluated 224 patients with asymptomatic rotator cuff tears. They showed that at a median follow-up of 5 years, tear progression was seen in 49% of the shoulders, and 49% of patients developed new pain. Thus, it is possible that the gradual progression of partial- to full-thickness retears and subsequent clinical symptoms may require more time to become clinically apparent. Jeon et al21 compared clinical outcomes between patients with healed and nonhealed tendons after rotator cuff repairs and found that patients with healed repairs had significantly improved ASES and Constant scores and greater strength. Yang et al57 conducted a meta-analysis in 2017 comparing clinical outcomes between intact and retorn rotator cuffs after arthroscopic repair, including 2611 patients with a mean follow-up of 25 months. They concluded that patients with a full-thickness rotator cuff retear exhibited significantly lower clinical outcome scores and strength when compared with patients with an intact or partially torn rotator cuff.

Tendon healing outcomes among studies comparing types of DR repairs are heterogeneous. In 2015, Brown et al6 performed a meta-analysis comparing conventional DR repair with TOE configuration and found no significant difference in retear rate independent of the tear size. However, other authors have demonstrated a significantly reduced rate of reruptures in large and massive tears with TOE repair as compared with DR. Mihata et al31 evaluated healing rates at a mean follow-up of 38 months according to tear size. In the large and massive tear subgroup, the retear rate was 7.5% in the TOE repair group but 41.7% in the DR repair group. Only a few studies directly compared DR with knotted TOE (Table 2).

Results regarding retears in studies directly comparing knotless and knot-tying TOE are also conflicting. Boyer et al,4 Kim et al,26 and Hug et al19 compared healing rates in TOE rotator cuff repairs with and without tying the medial row. The overall retear rates among the studies varied from 23% to 25% for the knot-tying TOE and from 17% to 22% in the knotless group. None of the authors found a statistically significant difference in retear rates between groups. Conversely, Rhee et al47 and Millett et al33 found significantly lower retears with the knotless TOE technique. Rhee et al found that the retear rate was significantly lower in the knot-tying group (5.9%) than in the knotless group (18.6%; P = .001). Similarly, Millett et al33 found significantly lower retears with the knotless TOE technique. In their study, the retear rate was 33.3% in shoulders with knotted suture-bridging repair and 7.5% in shoulders with knotless tape-bridging repair.

Finally, concern exists about the high percentages of rupture at the myotendinous junction reported in some studies with DR and knotting TOE.9,17 Tendinous strangulation at the medial knot of the tendon-bone fixation could disrupt tendinous microcirculation and lead to insufficiency with retears.9 Cho et al9 described 2 patterns of retears, in which type 1 is failure at the tendon-bone interface and type 2 is medial cuff failure with remnant cuff attached to the greater tuberosity. Type 2 retears are more challenging to repair and could hinder a revision surgery. Bedeir et al3 recently performed a systematic review of the literature on patterns of retear, comparing SR, DR, TOE, and knotless TOE. The estimated incidence rate of type 2 retear was 24% with SR, 43% with DR, 62% with TOE, and 38% with knotless TOE. The authors concluded that the DR and TOE techniques significantly increase the risk of medial cuff failure. However, some recent comparative studies did not find significant differences in the rate of type 2 retears when comparing knotted and knotless TOE configurations.26,33

Conclusion

There is substantial evidence indicating that DR repair restores more of the anatomic rotator cuff footprint and is biomechanically superior to SR repair. Moreover, DR repairs result in better functional outcomes and fewer retears than SR repairs, especially for tears >3 cm. TOE techniques have shown promising benefits in the laboratory setting as compared with traditional DR repairs, which could improve the healing environment. The important advantages include increased contact at the rotator cuff footprint, higher pressure at the tendon-bone interface, and increased failure strength in comparison with conventional DR repair. Nevertheless, there are no high-quality clinical studies comparing different DR configurations, and many of the theoretical advantages of TOE techniques over conventional DR techniques have yet to be proven. There is some limited evidence that knotted and knotless TOE techniques improve healing rates and functional outcomes in large and massive tears as compared with SR and DR. However, for small and medium tears, most of the studies showed similar results, and there are currently not enough clinical data to determine the functional advantages of various DR technique modifications.

Appropriately powered rigorous level 1 studies that directly compare DR techniques with knotted and knotless TOE techniques in matched tear patterns are necessary to further address these questions.

Footnotes

One or more of the authors has declared the following potential conflict of interest or source of funding: S.A.R. has received consulting fees from DePuy, nonconsulting fees and educational support from Arthrex, and honoraria from the Musculoskeletal Transplant Foundation and Vericel. AOSSM checks author disclosures against the Open Payments Database (OPD). AOSSM has not conducted an independent investigation on the OPD and disclaims any liability or responsibility relating thereto.

References

  • 1. Atesok K, Fu FH, Wolf MR, et al. Augmentation of tendon-to-bone healing. J Bone Joint Surg Am. 2014;96(6):513–521. [DOI] [PubMed] [Google Scholar]
  • 2. Barber FA, Drew OR. A biomechanical comparison of tendon-bone interface motion and cyclic loading between single-row, triple-loaded cuff repairs and double-row, suture-tape cuff repairs using biocomposite anchors. Arthroscopy. 2012;28(9):1197–1205. [DOI] [PubMed] [Google Scholar]
  • 3. Bedeir YH, Schumaier AP, Abu-Sheasha G, Grawe BM. Type 2 retear after arthroscopic single-row, double-row and suture bridge rotator cuff repair: a systematic review. Eur J Orthop Surg Traumatol. 2019;29(2):373–382. [DOI] [PubMed] [Google Scholar]
  • 4. Boyer P, Bouthors C, Delcourt T, et al. Arthroscopic double-row cuff repair with suture-bridging: a structural and functional comparison of two techniques. Knee Surg Sports Traumatol Arthrosc. 2015;23(2):478–486. [DOI] [PubMed] [Google Scholar]
  • 5. Brady PC, Arrigoni P, Burkhart SS. Evaluation of residual rotator cuff defects after in vivo single- versus double-row rotator cuff repairs. Arthroscopy. 2006;22(10):1070–1075. [DOI] [PubMed] [Google Scholar]
  • 6. Brown MJ, Pula DA, Kluczynski MA, Mashtare T, Bisson LJ. Does suture technique affect re-rupture in arthroscopic rotator cuff repair? A meta-analysis. Arthroscopy. 2015;31(8):1576–1582. [DOI] [PubMed] [Google Scholar]
  • 7. Burkhart SS, Adams CR, Burkhart SS, Schoolfield JD. A biomechanical comparison of 2 techniques of footprint reconstruction for rotator cuff repair: the SwiveLock-FiberChain construct versus standard double-row repair. Arthroscopy. 2009;25(3):274–281. [DOI] [PubMed] [Google Scholar]
  • 8. Busfield BT, Glousman RE, McGarry MH, Tibone JE, Lee TQ. A biomechanical comparison of 2 technical variations of double-row rotator cuff fixation: the importance of medial row knots. Am J Sports Med. 2008;36(5):901–906. [DOI] [PubMed] [Google Scholar]
  • 9. Cho NS, Yi JW, Lee BG, Rhee YG. Retear patterns after arthroscopic rotator cuff repair: single-row versus suture bridge technique. Am J Sports Med. 2010;38(4):664–671. [DOI] [PubMed] [Google Scholar]
  • 10. Chona DV, Lakomkin N, Lott A, et al. The timing of retears after arthroscopic rotator cuff repair. J Shoulder Elbow Surg. 2017;26(11):2054–2059. [DOI] [PubMed] [Google Scholar]
  • 11. Collin P, Colmar M, Thomazeau H, et al. Clinical and MRI outcomes 10 years after repair of massive posterosuperior rotator cuff tears. J Bone Joint Surg Am. 2018;100(21):1854–1863. [DOI] [PubMed] [Google Scholar]
  • 12. Collin P, Thomazeau H, Walch G, et al. Clinical and structural outcome twenty years after repair of isolated supraspinatus tendon tears. J Shoulder Elbow Surg. 2019;28(1):196–202. [DOI] [PubMed] [Google Scholar]
  • 13. Gerber C, Schneeberger AG, Beck M, Schlegel U. Mechanical strength of repairs of the rotator cuff. J Bone Joint Surg Br. 1994;76(3):371–380. [PubMed] [Google Scholar]
  • 14. Haque A, Pal Singh H. Does structural integrity following rotator cuff repair affect functional outcomes and pain scores? A meta-analysis. Shoulder Elbow. 2018;10(3):163–169. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15. Hashiguchi H, Iwashita S, Sonoki K, Abe K, Yoneda M, Takai S. Clinical outcomes and structural integrity of arthroscopic double-row versus suture-bridge repair for rotator cuff tears. J Orthop. 2018;15(2):396–400. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16. Hatta T, Giambini H, Hooke AW, et al. Comparison of passive stiffness changes in the supraspinatus muscle after double-row and knotless transosseous-equivalent rotator cuff repair techniques: a cadaveric study. Arthroscopy. 2016;32(10):1973–1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17. Hayashida K, Tanaka M, Koizumi K, Kakiuchi M. Characteristic retear patterns assessed by magnetic resonance imaging after arthroscopic double-row rotator cuff repair. Arthroscopy. 2012;28(4):458–464. [DOI] [PubMed] [Google Scholar]
  • 18. Hohmann E, König A, Kat C-J, Glatt V, Tetsworth K, Keough N. Single- versus double-row repair for full-thickness rotator cuff tears using suture anchors: a systematic review and meta-analysis of basic biomechanical studies. Eur J Orthop Surg Traumatol. 2018;28(5):859–868. [DOI] [PubMed] [Google Scholar]
  • 19. Hug K, Gerhardt C, Haneveld H, Scheibel M. Arthroscopic knotless-anchor rotator cuff repair: a clinical and radiological evaluation. Knee Surg Sports Traumatol Arthrosc. 2015;23(9):2628–2634. [DOI] [PubMed] [Google Scholar]
  • 20. Jancuska J, Matthews J, Miller T, Kluczynski MA, Bisson LJ. A systematic summary of systematic reviews on the topic of the rotator cuff. Orthop J Sports Med. 2018;6(9):2325967118797891. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21. Jeon YS, Kim RG, Shin S-J. What influence does progression of a nonhealing rotator cuff tear have on shoulder pain and function? Clin Orthop Relat Res. 2017;475(6):1596–1604. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22. Kaplan K, ElAttrache NS, Vazquez O, Chen Y-J, Lee T. Knotless rotator cuff repair in an external rotation model: the importance of medial-row horizontal mattress sutures. Arthroscopy. 2011;27(4):471–478. [DOI] [PubMed] [Google Scholar]
  • 23. Keener JD, Galatz LM, Teefey SA, et al. A prospective evaluation of survivorship of asymptomatic degenerative rotator cuff tears. J Bone Joint Surg. 2015;97(2):89–98. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24. Kim DH, ElAttrache NS, Tibone JE, et al. Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair. Am J Sports Med. 2006;34(3):407–414. [DOI] [PubMed] [Google Scholar]
  • 25. Kim KC, Shin HD, Lee WY, Han SC. Repair integrity and functional outcome after arthroscopic rotator cuff repair. Am J Sports Med. 2012;40(2):294–299. [DOI] [PubMed] [Google Scholar]
  • 26. Kim KC, Shin HD, Lee W-Y, Yeon K-W, Han S-C. Clinical outcomes and repair integrity of arthroscopic rotator cuff repair using suture-bridge technique with or without medial tying: prospective comparative study. J Orthop Surg Res. 2018;13(1):212. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27. Lee KW, Yang DS, Lee GS, Ma CH, Choy WS. Clinical outcomes and repair integrity after arthroscopic full-thickness rotator cuff repair: suture-bridge versus double-row modified Mason-Allen technique. J Shoulder Elbow Surg. 2018;27(11):1953–1959. [DOI] [PubMed] [Google Scholar]
  • 28. Lee TQ. Current biomechanical concepts for rotator cuff repair. Clin Orthop Surg. 2013;5(2):89–97. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29. Meier SW, Meier JD. The effect of double-row fixation on initial repair strength in rotator cuff repair: a biomechanical study. Arthroscopy. 2006;22(11):1168–1173. [DOI] [PubMed] [Google Scholar]
  • 30. Meier SW, Meier JD. Rotator cuff repair: the effect of double-row fixation on three-dimensional repair site. J Shoulder Elbow Surg. 2006;15(6):691–696. [DOI] [PubMed] [Google Scholar]
  • 31. Mihata T, Watanabe C, Fukunishi K, et al. Functional and structural outcomes of single-row versus double-row versus combined double-row and suture-bridge repair for rotator cuff tears. Am J Sports Med. 2011;39(10):2091–2098. [DOI] [PubMed] [Google Scholar]
  • 32. Milano G, Grasso A, Zarelli D, Deriu L, Cillo M, Fabbriciani C. Comparison between single-row and double-row rotator cuff repair: a biomechanical study. Knee Surg Sports Traumatol Arthrosc. 2008;16(1):75–80. [DOI] [PubMed] [Google Scholar]
  • 33. Millett PJ, Espinoza C, Horan MP, et al. Predictors of outcomes after arthroscopic transosseous equivalent rotator cuff repair in 155 cases: a propensity score weighted analysis of knotted and knotless self-reinforcing repair techniques at a minimum of 2 years. Arch Orthop Trauma Surg. 2017;137(10):1399–1408. [DOI] [PubMed] [Google Scholar]
  • 34. Millett PJ, Warth RJ, Dornan GJ, Lee JT, Spiegl UJ. Clinical and structural outcomes after arthroscopic single-row versus double-row rotator cuff repair: a systematic review and meta-analysis of level I randomized clinical trials. J Shoulder Elbow Surg. 2014;23(4):586–597. [DOI] [PubMed] [Google Scholar]
  • 35. Nassos JT, ElAttrache NS, Angel MJ, Tibone JE, Limpisvasti O, Lee TQ. A watertight construct in arthroscopic rotator cuff repair. J Shoulder Elbow Surg. 2012;21(5):589–596. [DOI] [PubMed] [Google Scholar]
  • 36. Oguma H, Murakami G, Takahashi-Iwanaga H, Aoki M, Ishii S. Early anchoring collagen fibers at the bone-tendon interface are conducted by woven bone formation: light microscope and scanning electron microscope observation using a canine model. J Orthop Res. 2001;19(5):873–880. [DOI] [PubMed] [Google Scholar]
  • 37. Park J-Y, Lee S-Y, Chung SW, Zulkifli H, Cho J-H, Oh K-S. Clinical comparison between double-row and transosseous-equivalent repairs for medium to large size rotator cuff tears. Arch Orthop Trauma Surg. 2013;133(12):1727–1734. [DOI] [PubMed] [Google Scholar]
  • 38. Park MC, Cadet ER, Levine WN, Bigliani LU, Ahmad CS. Tendon-to-bone pressure distributions at a repaired rotator cuff footprint using transosseous suture and suture anchor fixation techniques. Am J Sports Med. 2005;33(8):1154–1159. [DOI] [PubMed] [Google Scholar]
  • 39. Park MC, ElAttrache NS, Ahmad CS, Tibone JE. “Transosseous-equivalent” rotator cuff repair technique. Arthroscopy. 2006;22(12):1360. [DOI] [PubMed] [Google Scholar]
  • 40. Park MC, ElAttrache NS, Tibone JE, Ahmad CS, Jun B-J, Lee TQ. Part I: footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Shoulder Elbow Surg. 2007;16(4):461–468. [DOI] [PubMed] [Google Scholar]
  • 41. Park MC, Idjadi JA, ElAttrache NS, Tibone JE, McGarry MH, Lee TQ. The effect of dynamic external rotation comparing 2 footprint-restoring rotator cuff repair techniques. Am J Sports Med. 2008;36(5):893–900. [DOI] [PubMed] [Google Scholar]
  • 42. Park MC, Tibone JE, ElAttrache NS, Ahmad CS, Jun B-J, Lee TQ. Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Shoulder Elbow Surg. 2007;16(4):469–476. [DOI] [PubMed] [Google Scholar]
  • 43. Pauly S, Kieser B, Schill A, Gerhardt C, Scheibel M. Biomechanical comparison of 4 double-row suture-bridging rotator cuff repair techniques using different medial-row configurations. Arthroscopy. 2010;26(10):1281–1288. [DOI] [PubMed] [Google Scholar]
  • 44. Perser K, Godfrey D, Bisson L. Meta-analysis of clinical and radiographic outcomes after arthroscopic single-row versus double-row rotator cuff repair. Sports Health. 2011;3(3):268–274. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 45. Piper CC, Hughes AJ, Ma Y, Wang H, Neviaser AS. Operative versus nonoperative treatment for the management of full-thickness rotator cuff tears: a systematic review and meta-analysis. J Shoulder Elbow Surg. 2018;27(3):572–576. [DOI] [PubMed] [Google Scholar]
  • 46. Prasathaporn N, Kuptniratsaikul S, Kongrukgreatiyos K. Single-row repair versus double-row repair of full-thickness rotator cuff tears. Arthroscopy. 2011;27(7):978–985. [DOI] [PubMed] [Google Scholar]
  • 47. Rhee YG, Cho NS, Parke CS. Arthroscopic rotator cuff repair using modified Mason-Allen medial row stitch: knotless versus knot-tying suture bridge technique. Am J Sports Med. 2012;40(11):2440–2447. [DOI] [PubMed] [Google Scholar]
  • 48. Sheibani-Rad S, Giveans MR, Arnoczky SP, Bedi A. Arthroscopic single-row versus double-row rotator cuff repair: a meta-analysis of the randomized clinical trials. Arthroscopy. 2013;29(2):343–348. [DOI] [PubMed] [Google Scholar]
  • 49. Smith CD, Alexander S, Hill AM, et al. A biomechanical comparison of single and double-row fixation in arthroscopic rotator cuff repair. J Bone Joint Surg Am. 2006;88(11):2425–2431. [DOI] [PubMed] [Google Scholar]
  • 50. Sobhy MH, Khater AH, Hassan MR, El Shazly O. Do functional outcomes and cuff integrity correlate after single- versus double-row rotator cuff repair? A systematic review and meta-analysis study. Eur J Orthop Surg Traumatol. 2018;28(4):593–605. [DOI] [PubMed] [Google Scholar]
  • 51. Spang JT, Buchmann S, Brucker PU, et al. A biomechanical comparison of 2 transosseous-equivalent double-row rotator cuff repair techniques using bioabsorbable anchors: cyclic loading and failure behavior. Arthroscopy. 2009;25(8):872–879. [DOI] [PubMed] [Google Scholar]
  • 52. Tashjian RZ, Hoy RW, Helgerson JR, Guss AD, Henninger HB, Burks RT. Biomechanical comparison of transosseous knotless rotator cuff repair versus transosseous equivalent repair: half the anchors with equivalent biomechanics? Arthroscopy. 2018;34(1):58–63. [DOI] [PubMed] [Google Scholar]
  • 53. Vaishnav S, Millett PJ. Arthroscopic rotator cuff repair: Scientific rationale, surgical technique, and early clinical and functional results of a knotless self-reinforcing double-row rotator cuff repair system. J Shoulder Elbow Surg. 2010;19(2):83–90. [DOI] [PubMed] [Google Scholar]
  • 54. Wall LB, Keener JD, Brophy RH. Double-row vs single-row rotator cuff repair: a review of the biomechanical evidence. J Shoulder Elbow Surg. 2009;18(6):933–941. [DOI] [PubMed] [Google Scholar]
  • 55. Weeks KD, Dines JS, Rodeo SA, Bedi A. The basic science behind biologic augmentation of tendon-bone healing: a scientific review. Instr Course Lect. 2014;63:443–450. [PubMed] [Google Scholar]
  • 56. Xu C, Zhao J, Li D. Meta-analysis comparing single-row and double-row repair techniques in the arthroscopic treatment of rotator cuff tears. J Shoulder Elbow Surg. 2014;23(2):182–188. [DOI] [PubMed] [Google Scholar]
  • 57. Yang J, Robbins M, Reilly J, Maerz T, Anderson K. The clinical effect of a rotator cuff retear: a meta-analysis of arthroscopic single-row and double-row repairs. Am J Sports Med. 2017;45(3):733–741. [DOI] [PubMed] [Google Scholar]
  • 58. Ying Z, Lin T, Yan S. Arthroscopic single-row versus double-row technique for repairing rotator cuff tears: a systematic review and meta-analysis. Orthop Surg. 2014;6(4):300–312. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 59. Zhang Q, Ge H, Zhou J, Yuan C, Chen K, Cheng B. Single-row or double-row fixation technique for full-thickness rotator cuff tears: a meta-analysis. PloS One. 2013;8(7):e68515. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Orthopaedic Journal of Sports Medicine are provided here courtesy of SAGE Publications

RESOURCES