Skip to main content
Journal of Clinical Laboratory Analysis logoLink to Journal of Clinical Laboratory Analysis
. 1998 Dec 7;11(5):267–286. doi: 10.1002/(SICI)1098-2825(1997)11:5<267::AID-JCLA5>3.0.CO;2-4

More reliable diagnosis of infection with human immunodeficiency virus type 1 (HIV‐1) by detection of antibody IgGs to pol and gag proteins of HIV‐1 and p24 antigen of HIV‐1 in urine, saliva, and/or serum with highly sensitive and specific enzyme immunoassay (immune complex transfer enzyme immunoassay): A review

Seiichi Hashida 1, Kazuya Hashinaka 1, Setsuko Ishikawa 1, Eiji Ishikawa 1,
PMCID: PMC6760712  PMID: 9292394

Abstract

Ultrasensitive enzyme immunoassays (immune complex transfer enzyme immunoassays) were developed for antibody IgGs to HIV‐1 using recombinant reverse transcriptase (rRT), p17 (rp17), and p24 (rp24) as antigens. Antibody IgGs were reacted with 2,4‐dinitrophenyl‐recombinant antigens and recombinant antigen‐β‐d‐galactosidase conjugates, and the immune complexes formed, comprising the three components, were trapped onto polystyrene beads coated with (anti‐2,4‐dinitrophenyl group) IgG. After washing, the immune complexes were eluted from the polystyrene beads with excess of ϵN‐2,4‐dinitrophenyl‐l‐lysine and were transferred to clean polystyrene beads coated with (antihuman IgG γ‐chain ) IgG. β‐d‐Galactosidase activity bound to the last polystyrene beads was assayed by fluorometry. By transfer of the immune complexes from one solid phase to another, the nonspecific binding of the β‐d‐galactosidase conjugates was minimized and the sensitivity was markedly improved. The immune complex transfer enzyme immunoassays using rRT, rp17, and rp24 as antigens were 300–1,000‐fold, 1,000–3,000‐fold, and 30–100‐fold, respectively, more sensitive than Western blotting for the corresponding antigens and 10–300‐fold more sensitive than a conventional ELISA and a gelatin particle agglutination test. For urine (100 μl), whole saliva (1 μl), and serum (1 μl) samples, the sensitivity and specificity of the immune complex transfer enzyme immunoassay using rRT as antigen were both 100%. However, for urine samples in which the specific activities of antibody IgG to RT, p17, and p24 were much lower than those in serum samples probably due to degradation by the kidney, a longer assay of bound β‐d‐galactosidase activity or/and a concentration process for urine was required. The use of more than 1 μl of whole saliva was recommended for reliable diagnosis of the infections, whereas 1μl of serum was sufficient for the purpose. The positivity with rRT as antigen could be confirmed by demonstration of antibody IgGs to p17 and p24 in most of the urine, whole saliva, and serum samples. In HIV‐1 seroconversion serum panels, antibody IgG to p17 was detected as early as or even earlier than antibodies to HIV‐1 by a conventional ELISA or/and a gelatin particle agglutination test, whereas antibody IgGs to RT and p24 were detected as early as or later than antibody IgG to p17. Thus the uses of rRT and rp17 as antigens were advantageous over that of the other antigens for randomly collected serum samples probably long after the infection and serum samples at early stages of the infection, respectively. On the basis of these results and other reports, the immune complex transfer enzyme immunoassay was developed for simultaneous detection of p24 antigen and antibody IgGs to RT and p17 in a single assay tube, and the window period (8 weeks, although widely variable), during which diagnosis of HIV‐1 infection is not possible due to the absence of detectable antibodies to HIV‐1, was shortened by 2 weeks. As a result, the simultaneous detection made possible not only as early diagnosis as that by detection of p24 antigen, but also as reliable diagnosis as that by detection of antibodies to HIV‐1. Finally, the immune complex transfer enzyme immunoassay has been recently improved so as to be performed within shorter periods of time (2–3 hr) with higher sensitivity, and testing many samples has become easy. J. Clin. Lab. Anal. 11:267–286, 1997. © 1997 Wiley‐Liss, Inc.

Keywords: human immunodeficiency virus type 1, antigen, antibody, reverse transcriptase, p17, p24, enzyme immunoassay, β‐d‐galactosidase

References

  • 1. Constantine NT: Serologic tests for the retroviruses: Approaching a decade of evolution. AIDS 1: 1–13, 1993. [DOI] [PubMed] [Google Scholar]
  • 2. Barbé F, Klein M, Badonnel Y: Early detection of antibodies to human immunodeficiency virus 1 by a third‐generation enzyme immunoassay. Ann Biol Clin 52: 341–345, 1994. [PubMed] [Google Scholar]
  • 3. de Saussure P, Yerly S, Tullen E, Perrin LH: Human immunodeficiency virus type 1 nucleic acids detected before p24 antigenemia in a blood donor. Transfusion 33: 164–167, 1993. [DOI] [PubMed] [Google Scholar]
  • 4. Allain JP, Laurian Y, Paul DA, Senn D: Serological markers in early stages of human immunodeficiency virus infection in haemophiliacs. Lancet ii: 1233–1236, 1986. [DOI] [PubMed] [Google Scholar]
  • 5. Goudsmit J, de Wolf F, Paul DA, Epstein LG, Lange JMA, Krone WJA, Speelman H, Wolters EC, Van der Noordaa J, Oleske JM, Van der Helm HJ, Coutinho RA: Expression of human immunodeficiency virus antigen (HIV‐Ag) in serum and cerebrospinal fluid during acute and chronic infection. Lancet ii: 177–180, 1986. [DOI] [PubMed] [Google Scholar]
  • 6. Von Sydow M, Gaines H, Sönnerborg A, Forsgren M, Pehrson PO, Strannegård Ö: Antigen detection in primary HIV infection. Br Med J 296: 238–240, 1988. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7. Loveday C, Tedder RS: Enzyme‐linked immunosorbent assays for the measurement of human immunodeficiency virus, type 1 reverse tran‐scriptase antigen and antibodies. J Virol Methods 41: 181–192, 1993. [DOI] [PubMed] [Google Scholar]
  • 8. Downie JC, Howard R, Bowcock B, Cunningham AL: HIV‐1 antibody testing strategy: evaluation of ELISA screening and Western blot profiles in a mixed low risk/high risk patient population. J Virol Method 26: 291–304, 1989. [DOI] [PubMed] [Google Scholar]
  • 9. Genesca J, Wai‐Kuo Shih J, Jett BW, Hewlett IK, Epstein JS, Alter HJ: What do Western blot indeterminate patterns for human immunodeficiency virus mean in EIA‐negative blood donors? Lancet ii: 1023–1025, 1989. [DOI] [PubMed] [Google Scholar]
  • 10. Ng VL, Chiang CS, Debouck C, McGrath MS, Grove TH, Mills J: Reliable confirmation of antibodies to human immunodeficiency virus type 1 (HIV‐1) with an enzyme‐linked immunoassay using recombinant antigens derived from the HIV‐1 gag, pol, and env genes. J Clin Microbiol 27: 977–982, 1989. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11. Friedland GH, Klein RS: Transmission of the human immunodeficiency virus. N Engl J Med 311: 1125–1135, 1987. [DOI] [PubMed] [Google Scholar]
  • 12. Hashida S, Hashinaka K, Saitoh A, Takamizawa A, Shinagawa H, Oka S, Shimada K, Hirota K, Kohno T, Ishikawa S, Ishikawa E: Diagnosis of HIV‐1 infection by detection of antibody IgG to HIV‐1 in urine with ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) using recombinant proteins as antigens. J Clin Lab Anal 8: 237–246, 1994. [DOI] [PubMed] [Google Scholar]
  • 13. Mortimer PP, Parry JV: Detection of antibody to HIV in saliva: a brief review. Clin Diagnostic Virol 2: 231–243, 1994. [DOI] [PubMed] [Google Scholar]
  • 14. Tamashiro H, Constantine NT: Serological diagnosis of HIV infection using oral fluid samples. Bull WHO 72: 135–143, 1994. [PMC free article] [PubMed] [Google Scholar]
  • 15. Hashida S, Hirota K, Hashinaka K, Saitoh A, Nakata A, Shinagawa H, Oka S, Shimada K, Mimaya J, Matsushita S, Ishikawa E: Detection of antibody IgG to HIV‐1 in urine by sensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) using recombinant proteins as antigens for diagnosis of HIV‐1 infection. J Clin Lab Anal 7: 353–364, 1993. [DOI] [PubMed] [Google Scholar]
  • 16. Hashinaka K, Hashida S, Hirota K, Saitoh A, Nakata A, Shinagawa H, Oka S, Shimada K, Ishikawa E: Detection of anti‐human immunodeficiency virus type 1 (HIV‐1) immunoglobulin G in urine by an ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) with recombinant reverse transcriptase as an antigen. J Clin Microbiol 32: 819–822, 1994. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17. Hashida S, Hashinaka K, Hirota K, Saitoh A, Nakata A, Shinagawa H, Oka S, Shimada K, Mimaya J, Matsushita S, Ishikawa E: Detection of antibody IgG to HIV‐1 in urine by ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) using recombinant p24 as antigen for diagnosis of HIV‐1 infection. J Clin Lab Anal 8: 86–95, 1994. [DOI] [PubMed] [Google Scholar]
  • 18. Ishikawa S, Hashida S, Hashinaka K, Hirota K, Saitoh A, Takamizawa A, Shinagawa H, Oka S, Shimada K, Ishikawa E: Diagnosis of HIV‐1 infection with whole saliva by detection of antibody IgG to HIV‐1 with ultrasensitive enzyme immunoassay using recombinant reverse transcriptase as antigen. J Acquir Immune Defic Syndr Human Retrovirol 10: 41–47, 1995. [PubMed] [Google Scholar]
  • 19. Hashida S, Hashinaka K, Nishikata I, Oka S, Shimada K, Saitoh A, Takamizawa A, Shinagawa H, Yano S, Kojima H, Izumi T, Ishikawa E: Immune complex transfer enzyme immunoassay that is more sensitive and specific than Western blotting for detection of antibody immunoglobulin G to human immunodeficiency virus type 1 in serum with recombinant pol and gag proteins as antigens. Clin Diag Lab Immunol 2: 535–541, 1995. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20. Hashida S, Hashinaka K, Nishikata I, Oka S, Shimada K, Saitoh A, Takamizawa A, Shinagawa H, Ishikawa E: Shortening of the window period in diagnosis of HIV‐1 infection by simultaneous detection of p24 antigen and antibody IgG to p17 and reverse transcriptase in serum with ultrasensitive enzyme immunoassay. J Virol Methods 62: 43–53, 1996. [DOI] [PubMed] [Google Scholar]
  • 21. Hashida S, Hashinaka K, Nishikata I, Saitoh A, Takamizawa A, Shinagawa H, Ishikawa E: Earlier diagnosis of HIV‐1 infection by simultaneous detection of p24 antigen and antibody IgGs to p17 and reverse transcriptase in serum with enzyme immunoassay. J Clin Lab Anal 10: 213–219, 1996. [DOI] [PubMed] [Google Scholar]
  • 22. Hashida S, Hashinaka K, Nishikata I, Oka S, Shimada K, Saitoh A, Takamizawa A, Shinagawa H, Ishikawa E: Measurement of human immunodeficiency virus type 1 p24 in serum by an ultrasensitive enzyme immunoassay, the two‐site immune complex transfer enzyme immunoassay. J Clin Microbiol 33: 298–303, 1995. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23. Ishikawa E, Hashida S, Kohno T, Hirota K, Hashinaka K, Ishikawa S: Principle and applications of ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) for antibodies in body fluids. J Clin Lab Anal 7: 376–393, 1993. [DOI] [PubMed] [Google Scholar]
  • 24. Hashinaka K, Hashida S, Saitoh A, Nakata A, Shinagawa H, Oka S, Shimada K, Ishikawa E: Conjugation of recombinant reverse transcriptase of HIV‐1 to p‐D‐galactosidase from Escherichia coli for ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) of anti‐HIV‐1 IgG. J Immunol Methods 172: 179–187, 1994. [DOI] [PubMed] [Google Scholar]
  • 25. Saitoh A, Iwasaki H, Nakata A, Adachi A, Shinagawa H: Overproduction of human immunodeficiency virus type I reverse transcriptase in Escherichia coli and purification of the enzyme. Microbiol Immunol 34: 509–521, 1990. [DOI] [PubMed] [Google Scholar]
  • 26. Saitoh A, Tanaka N, Nakata A, Ikuta K, Shinagawa H: A unique monoclonal antibody that recognizes mature p17 of HIV‐1 but not its precursor. Microbiol Immunol 36: 105–111, 1992. [DOI] [PubMed] [Google Scholar]
  • 27. Tanaka N, Saitoh A, Nakata A, Shinagawa H: A simple method for overproduction and purification of p24 gag protein of human immunodeficiency virus type 1. Microbiol Immunol 36: 823–831, 1992. [DOI] [PubMed] [Google Scholar]
  • 28. Adachi A, Gendelman HE, Koenig S, Folks T, Willey R, Rabson A, Martin MA: Production of acquired immunodeficiency syndrome‐associated retrovirus in human and nonhuman cells transfected with an infectious molecular clone. J Virol 59: 284–291, 1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29. Wain‐Hobson S, Sonigo P, Danos O, Cole S, Alizon M: Nucleotide sequence of the AIDS virus, LAV. Cell 40: 9–17, 1985. [DOI] [PubMed] [Google Scholar]
  • 30. Cao Y, Hosein B, Borkowsky W, Mirabile M, Baker L, Baldwin D, Poiesz BJ, Friedman‐Kien AE: Antibodies to human immunodeficiency virus type 1 in the urine specimens of HIV‐1—Seropositive individuals. AIDS Res Hum Retroviruses 5: 311–319, 1989. [DOI] [PubMed] [Google Scholar]
  • 31. Desai S, Bates H, Michalski FJ: Detection of antibody to HIV‐1 in urine. Lancet 337: 183–184, 1991. [DOI] [PubMed] [Google Scholar]
  • 32. Reagan KJ, Lile CC, Book GW, Devash Y, Winslow DL, Bincsik A: Use of urine for HIV‐1 antibody screening. Lancet 335: 358–359, 1990. [DOI] [PubMed] [Google Scholar]
  • 33. Connell JA, Parry JV, Mortimer PP, Duncan RJS, McLean KA, Johnson AM, Hambling MH, Barbara J, Farrington CP: Preliminary report: Accurate assays for anti‐HIV in urine. Lancet 335: 1366–1369, 1990. [DOI] [PubMed] [Google Scholar]
  • 34. Klokke AH, Ocheng D, Kalluvya SE, Nicoll AG, Laukamm‐Josten U, Parry JV, Mortimer PP, Connell JA: Field evaluation of immunoglobu‐lin G antibody capture tests for HIV‐1 and HIV‐2 antibodies in African serum, saliva and urine. AIDS 5: 1391–1392, 1991. [DOI] [PubMed] [Google Scholar]
  • 35. Thongcharoen P, Wasi C, Louisirirotchanakul S, Parry J, Connell J, Mortimer P: Immunoglobulin G antibody capture enzyme‐linked immunosorbent assay: a versatile assay for detection of anti‐human immunodeficiency virus type 1 and 2 antibodies in body fluids. J Clin Microbiol 30: 3288–3289, 1992. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36. Behets FM, Edidi B, Quinn TC, Atikala L, Bishagara K, Nzila N, Laga M, Piot P, Ryder RW, Brown CC: Detection of salivary HIV‐1‐specific IgG antibodies in high‐risk populations in Zaire. J AIDS 4: 183–187, 1991. [PubMed] [Google Scholar]
  • 37. Major CJ, Read SE, Coates RA, Francis A, MaLaughlin BJ, Millson M, Shepherd F, Fanning M, Calzavara L, MacFadden D, Johnson JK, O'Shaughnessy MV: Comparison of saliva and blood for human immunodeficiency virus prevalence testing. J Infect Dis 163: 699–702, 1991. [DOI] [PubMed] [Google Scholar]
  • 38. Soto‐Ramírez LE, Hernández‐Gómez L, Sifuentes‐Osornio J, Barriga‐Angulo G, de Lima DD, López‐Portillo M, Ruiz‐Palacios GM: Detection of specific antibodies in gingival crevicular transudate by enzyme‐linked immunosorbent assay for diagnosis of human immunodeficiency virus type 1 infection. J Clin Microbiol 30: 2780–2783, 1992. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39. Frerichs RR, Htoon MT, Eskes N, Lwin S: Comparison of saliva and serum for HIV surveillance in developing countries. Lancet 340: 1496–1499, 1992. [DOI] [PubMed] [Google Scholar]
  • 40. Johnson AM, Parry JV, Best SJ, Smith AM, de Silva M, Mortimer PP: HIV surveillance by testing saliva. AIDS 2: 369–371, 1988. [DOI] [PubMed] [Google Scholar]
  • 41. Crofts N, Nicholson S, Coghlan P, Gust ID: Testing of saliva for antibodies to HIV‐1. AIDS 5: 561–563, 1991. [PubMed] [Google Scholar]
  • 42. Roitt I, Lehner T: Oral immunity In Immunology of Oral Diseases, 2nd ed. Roitt I, Lehner T, eds. Blackwell, Oxford, 1983, pp 279–304. [Google Scholar]
  • 43. Parry JV, Perry KR, Mortimer PP: Sensitive assays for viral antibodies in saliva: an alternative to tests on serum. Lancet ii: 72–75, 1987. [DOI] [PubMed] [Google Scholar]
  • 44. Gershy‐Damet GM, Koffi K, Abouya L, Sasson‐Morokro M, Brattegaard K, Parry JV, De Cock KM, Mortimer PP: Salivary and urinary diagnosis of human immunodeficiency viruses 1 and 2 infection in Co̊te d'lvoire, using two assays. Trans R Soc Trap MedHyg 86: 670–671, 1992. [DOI] [PubMed] [Google Scholar]
  • 45. Ishikawa S, Hashida S, Hashinaka K, Hirota K, Kojima M, Saito A, Takamizawa A, Shinagawa H, Oka S, Shimada K, Ishikawa E: Whole saliva dried on filter paper for diagnosis of HIV‐1 infection by detection of antibody IgG to HIV‐1 with ultrasensitive enzyme immunoassay using recombinant reverse transcriptase as antigen. J Clin Lab Anal 10: 35–41, 1996. [DOI] [PubMed] [Google Scholar]
  • 46. Lange JMA, Coutinho RA, Krone WJA, Verdonck LF, Danner SA, Van der Noordaa J, Goudsmit J: Distinct IgG recognition patterns during progression of subclinical and clinical infection with lymphadenopathy associated virus/human T lymphotropic virus. Br Med J 292: 228–230, 1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 47. Soriano V, Tor J, Ribera A, Muga R: Synthetic peptide immunoassay in diagnosis of primary HIV infection. Vox Sang 58: 228–230, 1990. [DOI] [PubMed] [Google Scholar]
  • 48. Weber B, Hess G, Enzensberger R, Harms F, Evans CJ, Hamann A, Doerr HW: Multicenter evaluation of the novel ABN Western blot (immunoblot) system in comparison with an enzyme‐linked immunosorbent assay and a different Western blot. J Clin Microbiol 30: 691–697, 1992. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 49. Stramer SL, Heller JS, Coombs RW, Parry JV, Ho DD, Allain J‐P: Markers of HIV infection prior to IgG antibody seropositivity. JAMA 262: 64–69, 1989. [PubMed] [Google Scholar]
  • 50. Wolinsky SM, Rinaldo CR, Kwok S, Sninsky JJ, Gupta P, Imagawa D, Farzadegan H, Jacobson LP, Grovit KS, Lee MH, Chmiel JS, Ginzburg H, Kaslow RA, Phair JP: Human immunodeficiency virus type 1 (HIV‐1) infection a median of 18 months before a diagnostic Western blot. Ann IntMed 111: 961–972, 1989. [DOI] [PubMed] [Google Scholar]
  • 51. Ulstrup JC, Skaug K, Figenschau KJ, Ørstavik I, Bruun JN, Petersen G: Sensitivity of Western blotting (compared with ELISA and immuno‐fluorescence) during seroconversion after HTLV‐III infection. Lancet i: 1151–1152, 1986. [DOI] [PubMed] [Google Scholar]
  • 52. Nishanian P, Huskins KR, Stehn S, Detels R, Fahey JL: A simple method for improved assay demonstrates that HIV p24 antigen is present as immune complexes in most sera from HIV‐infected individuals. J Infect Dis 162: 21–28, 1990. [DOI] [PubMed] [Google Scholar]
  • 53. Vasudevachari MB, Salzman NP, Woll DR, Mast C, Uffelman KW, Toedter G, Hoefheinz D, Metcalf JA, Lane HC: Clinical utility of an enhanced human immunodeficiency virus type 1 p24 antigen capture assay. J Clin Immunol 13: 185–192, 1993. [DOI] [PubMed] [Google Scholar]
  • 54. Hashida S, Hashinaka K, Nishikata I, Saito A, Takamizawa A, Shinagawa H, Ishikawa E: Ultrasensitive and more specific enzyme immunoassay (immune complex transfer enzyme immunoassay) for p24 antigen of HIV‐1 in serum using affinity‐purified rabbit anti‐p24 Fab′ and monoclonal mouse anti‐p24 Fab′. J Clin Lab Anal 10: 302–307, 1996. [DOI] [PubMed] [Google Scholar]
  • 55. Chiang CS, Grove T, Cooper M, Cuan J, Kowaiski A, Parcells K, Tsunokawa M, Rosenberg M, Arcuri E, Franklin S, Smith T, Debouck C: Development of a confirmatory enzyme‐linked immunosorbent assay for HIV‐1 antibodies. Clin Chem 35: 946–952, 1989. [PubMed] [Google Scholar]
  • 56. Baur A, Vornhagen R, Korn K, Sonneborn HH, Eberlein B, Harrer T, Brockhaus W, Jahn G: Viral culture and p24 antigenemia of human immunodeficiency virus (HlV)‐infected individuals correlated with antibody profiles determined with recombinant polypeptides of all HIV‐1 open‐reading frames. J Infect Dis 165: 419–426, 1992. [DOI] [PubMed] [Google Scholar]
  • 57. Dalgleish A, Weiss RA: Human retroviruses In Principles and Practice of Clinical Virology. Zuckerman AJ, Banatvala JE, Pattison JR, eds. Wiley & Sons, New York, 1987, pp 517–543. [Google Scholar]
  • 58. Ishikawa S, Hashida S, Kohno T, Ishikawa E: Use of microplates and fluororeader for ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) of anti‐HTLV‐I IgG. J Clin Lab Anal 8: 327–331, 1994. [DOI] [PubMed] [Google Scholar]
  • 59. Ishikawa S, Hashida S, Nakamoto H, Tanaka S, Kojima M, Ishikawa E: Further simplification of ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) for anti‐HTLV‐I IgG using microplates and fluororeader. J Clin Lab Anal 9: 204–211, 1995. [DOI] [PubMed] [Google Scholar]
  • 60. Ishikawa S, Hashida S, Nakamoto H, Tanaka S, Kojima M, Ishikawa E: Simpler and more sensitive immune complex transfer enzyme immunoassay for anti‐HTLV‐I IgG using modified polystyrene beads, microplates and fluororeader. Anal Lett 28: 1611–1618, 1995. [DOI] [PubMed] [Google Scholar]
  • 61. Hashida S, Ishikawa S, Nakamoto H, Tanaka S, Kojima M, Ishikawa E: Simple and more sensitive immune complex transfer enzyme immunoassay for antibody IgG to reverse transcriptase of HIV‐1 using microplates, modified polystyrene solid phase, and fluororeader. J Clin Lab Anal 10: 294–301, 1996. [DOI] [PubMed] [Google Scholar]
  • 62. Ishikawa S, Hashida S, Hashinaka K, Kojima M, Saito A, Takamizawa A, Shinagawa H, Oka S, Shimada K, Ishikawa E: More sensitive immune complex transfer enzyme immunoassay for antibody IgG to p17 of HIV‐1 with shorter incubation time for immunoreactions and larger volumes of serum samples. J Clin Lab Anal 1997. (in press). [DOI] [PMC free article] [PubMed]

Articles from Journal of Clinical Laboratory Analysis are provided here courtesy of Wiley

RESOURCES