Abstract
Key points
The application of conventional cryogenic magnetoencephalography (MEG) to the study of cerebellar functions is highly limited because typical cryogenic sensor arrays are far away from the cerebellum and naturalistic movement is not allowed in the recording.
A new generation of MEG using optically pumped magnetometers (OPMs) that can be worn on the head during movement has opened up an opportunity to image the cerebellar electrophysiological activity non‐invasively.
We use OPMs to record human cerebellar MEG signals elicited by air‐puff stimulation to the eye.
We demonstrate robust responses in the cerebellum.
OPMs pave the way for studying the neurophysiology of the human cerebellum.
Abstract
We test the feasibility of an optically pumped magnetometer‐based magnetoencephalographic (OP‐MEG) system for the measurement of human cerebellar activity. This is to our knowledge the first study investigating the human cerebellar electrophysiology using optically pumped magnetometers. As a proof of principle, we use an air‐puff stimulus to the eyeball in order to elicit cerebellar activity that is well characterized in non‐human models. In three subjects, we observe an evoked component at approx. 50 ms post‐stimulus, followed by a second component at approx. 85–115 ms post‐stimulus. Source inversion localizes both components in the cerebellum, while control experiments exclude potential sources elsewhere. We also assess the induced oscillations, with time‐frequency decompositions, and identify additional sources in the occipital lobe, a region expected to be active in our paradigm, and in the neck muscles. Neither of these contributes to the stimulus‐evoked responses at 50–115 ms. We conclude that OP‐MEG technology offers a promising way to advance the understanding of the information processing mechanisms in the human cerebellum.
Keywords: optically pumped magnetometer, magnetoencephalography, cerebellum, eyeblink conditioning
Key points
The application of conventional cryogenic magnetoencephalography (MEG) to the study of cerebellar functions is highly limited because typical cryogenic sensor arrays are far away from the cerebellum and naturalistic movement is not allowed in the recording.
A new generation of MEG using optically pumped magnetometers (OPMs) that can be worn on the head during movement has opened up an opportunity to image the cerebellar electrophysiological activity non‐invasively.
We use OPMs to record human cerebellar MEG signals elicited by air‐puff stimulation to the eye.
We demonstrate robust responses in the cerebellum.
OPMs pave the way for studying the neurophysiology of the human cerebellum.
Introduction
Our understanding of cerebellar function has undergone a paradigm shift in recent decades due to studies of neuroanatomy (Glickstein et al. 2011) and neuropsychology (Schmahmann & Sherman, 1998) and functional magnetic resonance imaging (fMRI) (Stoodley & Schmahmann, 2009; Buckner, 2013). Until recently thought of as part of only the motor system, the cerebellum is essential for a variety of cognitive and social functions as indicated by accumulating evidence (Sokolov et al. 2017). Despite this expanding repertoire of cerebellar functions, there is a marked absence of human electrophysiological studies in this area.
In the domain of magnetoencephalography (MEG), a small body of research has documented cerebellar evoked potentials (Tesche & Karhu, 1997, 2000; Martin et al. 2006; Houck et al. 2007) or activity as a part of physiological (Gross et al. 2002; Tass et al. 2003; Pollok et al. 2004, 2005; Muthukumaraswamy et al. 2006; Jerbi et al. 2007) or pathological (Timmermann et al. 2003; Schnitzler et al. 2009) oscillatory networks. These MEG studies provided important insights. Nonetheless, they are scarce in comparison with other types of studies, especially fMRI, and have used limited varieties of tasks. It should also be noted that many of them reported cerebellar activation, but without examining or discussing it in detail. This poverty of reports is due to several factors. First, compared to the cerebral cortex, the cerebellar cortex is less favourable to the generation of a measurable MEG signal. Its densely folded anatomy causes a high degree of field attenuation due to locally opposing current sources (Tesche & Karhu, 1997; Hashimoto et al. 2003; Dalal et al. 2013). Second, cerebellar neurons are thought to have low firing synchrony, based on the small amplitudes observed in local field potential studies (Gerloff et al. 1996). Third, the majority of the cerebellum is located deep in the human cranium, so any electromagnetic sources are distant from typical SQUID‐based MEG sensors. These factors combined make it not unexpected that MEG signals generated in the cerebellum are smaller and less likely to be distinguishable compared to those produced by the neocortex. Further, to maintain signal quality and minimize co‐registration errors, cryogenic MEG requires subjects to remain very still and thus limits the application of many naturalistic movement paradigms relevant to cerebellar dysfunction (e.g. the finger–nose–finger test). The issue is not exclusive to MEG – to date, few studies with scalp cerebellar EEG have been reported (Muthukumaraswamy et al. 2003; Lascano et al. 2013; Todd et al. 2018). It is widely assumed that scalp EEG recordings for the cerebellum suffer from muscle artefacts (Muthukumaraswamy, 2013). Intracranial recordings in the cerebellum are also rare because of their limited clinical indications (Niedermeyer, 2004; Dalal et al. 2013). As a result, the electrophysiology of the human cerebellum is largely understudied compared to the neocortex.
The recent development of optically pumped magnetometers (OPMs) as a tool for MEG provides a new opportunity to investigate cerebellar electrophysiology. OPMs are high sensitivity magnetic field sensors. They do not need cryogenic cooling so can be flexibly placed on the scalp. We have recently built such a wearable OP‐MEG system, placing the sensors close to the scalp by mounting them in a 3D printed cast based on the individual's head MR imaging (Boto et al. 2017, 2018). The use of a 3D‐printed cast can accurately inform sensor positions and orientations with respect to the brain anatomy, thus facilitating accurate source imaging. This system potentially also reduces the sensor‐to‐brain distance to enhance signal magnitude (Boto et al. 2017). These sensors can be positioned in a dense array over a specific brain region of interest (Tierney et al. 2018), although at present only in modest numbers. Importantly, in combination with a field‐nulling apparatus (Holmes et al. 2018; Iivanainen et al. 2019), one can minimize magnetic field variation at the sensors due to head movement in the ambient field. Besides, this system is less susceptible to muscle artefacts compared to EEG (Boto et al. 2018). These characteristics combined allow non‐invasive mapping of human electrophysiology when subjects interact with the real world and even move freely (Boto et al. 2018), thus making OP‐MEG an ideal candidate for the study of cerebellar electrophysiology of both motor and non‐motor tasks.
As a proof‐of‐concept study, we recorded OP‐MEG data while delivering non‐noxious air‐puffs to the eye to trigger blinks. Air‐puffs are the unconditioned stimuli (US) in a well‐established cerebellar associative learning paradigm: eyeblink conditioning. In single‐unit recording experiments in animal models, the stimuli elicit activity in the principal cells of the cerebellum, the Purkinje cells. In untrained animals (Ohmae & Medina, 2015) these cells show both ‘simple spike’ responses driven by mossy fibre inputs from the brainstem pontine nuclei, and ‘complex spike’ responses to climbing fibres that project from the inferior olive to bilateral, predominantly ipsilateral, cerebellar cortices. Animals and humans present comparable behavioural responses to physiological and pathological (cerebellar lesion) interventions in this paradigm (see Freeman & Steinmetz (2011) for a review of the neural circuitry based on animal studies; see Gerwig et al. (2007) for a review of human lesion studies). Functional MRI studies in humans also accord well with corresponding electrophysiological studies in animals, with a prominent blood oxygenation level‐dependent response predominantly in the ipsilateral cerebellar cortex (Dimitrova et al. 2002; Cheng et al. 2008; Thurling et al. 2015). Consequently, cerebellar activation may well be expected in our OP‐MEG recording.
We aim here to demonstrate that neural signals in the cerebellum, which have been observed in response to air‐puff stimulation in both the invasive animal and non‐invasive human literature (e.g. fMRI), can be measured with OP‐MEG. We present evoked responses localized to the cerebellum, and other physiological signals relevant to the stimulation, including eye‐blinks, evoked responses in the somatosensory cortex and induced responses localized to the occipital area (Bardouille et al. 2006; Liu et al. 2017). Taken together, we show that wearable OP‐MEG provides a promising future to examine the cerebellum during human cognition and action, and in pathological conditions linked to cerebellar dysfunction.
Methods
This section is divided into three parts. First, we describe the OP‐MEG system. Second, we summarize the experimental procedures for cerebellar activity measurement. Finally, we introduce the inversion scheme used to localize the source activity.
Ethical approval
The study conformed to the standards set by the Declaration of Helsinki, except for registration in a database. The protocol was approved by the University of Nottingham Medical School Research Ethics Committee and the University of Birmingham Research Ethics Committee. Written informed consent was obtained from all participants. The experiments took place at the University of Nottingham.
Participants
Three healthy subjects (1 female, 2 male) aged 27–50, with no history of psychiatric or neurological diseases, participated in the study. All subjects were naïve to the eyeblink conditioning.
OP‐MEG system
The OP‐MEG system has been previously described in detail (Boto et al. 2017, 2018; Holmes et al. 2018; Tierney et al. 2018). Briefly, the system consists of an OPM sensor array within a customized cast of the head, and a field‐nulling apparatus comprising four reference OPM sensors and field‐nulling coils (Fig. 1).
Optically pumped magnetometer
The OPM sensors used here (QuSpin Inc., Louisville, CO, USA) have previously been described in detail (Shah & Wakai, 2013; Osborne et al. 2018). In brief, each OPM sensor incorporates three key components: a 795 nm wavelength laser, a 3 × 3 × 3 mm3 cell containing rubidium‐87 (87Rb) vapour, and a photodiode. The laser spin‐polarizes the 87Rb atoms in the direction of the laser beam. The photodiode perceives the intensity of the laser transmitting through the cell. At zero magnetic field, the cell is transparent to the laser light and the photodiode detects a maximal signal. A small local field (due to brain activity) causes Larmor procession of the 87Rb atoms, which decreases the transparency of the cell because some laser light is absorbed by the atoms. The output of the photodiode shows a zero‐field resonance with Lorentzian line shape, allowing the measurement of the field (Dupont‐Roc et al. 1969). In practice, the sensors have a bandwidth of approximately 0–130 Hz with a noise level of ∼15 fT/√Hz in the 1–100 Hz band, and a dynamic range of ±1.5 nT.
Each OPM sensor also contains a set of three coils which generate three orthogonal fields to cancel out the static field inside the vapour cell up to ∼50 nT. These on‐sensor coils compensate the ambient environmental field in a typical magnetic shield room (MSR) and allow sensors to operate at a fixed position and orientation. To keep the OPMs within their dynamic range during naturalistic movement, we further apply an array of bi‐planar coils to null the residual field inside the MSR (see the field nulling apparatus section).
Field nulling apparatus
The earth's residual static field in the Nottingham MSR is ∼25 nT with a maximal gradient of approximately 10 nT/m. This means that even minimal head movements (e.g. a 4‐degree rotation) can easily generate signals which exceed the OPM's dynamic range. In order to mitigate these effects, we used a set of bi‐planar coils to generate magnetic fields which counteract the remaining static field as measured by four reference sensors close to the head. By applying this method, the dominant components of the static field and field gradient can be diminished by factors of 46 and 13, respectively, in a volume of 40 × 40 × 40 cm3 encapsulating the head (Boto et al. 2018; Holmes et al. 2018).
Helmet design
Data from an anatomical T1‐weighted MRI scan were used to generate a 3D mesh representing the outer surface of each participant's scalp. This 3D mesh was used in 3D printing to shape the inner surface of a nylon ‘scanner‐cast’, as described (Boto et al. 2017; Meyer et al. 2017; Tierney et al. 2018), with sockets around the outer surface to hold the OPM sensors. Importantly, the mesh and subsequently produced wearable helmet provide accurate socket and thus sensor positions and orientations, which are in the same coordinate space as the MRI image. Therefore, no coregistration is needed and the sensor positions are defined as the centre of the socket bases with a 6.5 mm offset, which takes into account the distance between the outside of the sensor housing and the centre of the vapour cell (Osborne et al. 2018). Here, with limited numbers of sensors available, we placed the sensors proximal to the cerebellar and somatosensory cortices. Figure 1 shows the sensor configuration in a typical subject. Across the three participants, 13–19 posterior sensors and 4–6 somatosensory sensors were used. Additionally, two sensors were placed in bilateral infra‐orbital slots for eye‐blink detection (Fig. 1 A).
Experiment: eyeblink paradigm
Eyeblinks were elicited by a 32 ms air‐puff delivered through a nozzle mounted on the scanner‐cast (Fig. 1 A), essentially a pressurized air cylinder (1 bar) fed into a 10 m semi‐rigid plastic tube (2 mm internal diameter), under the control of a bespoke pneumatic valve controller. Some details of the pneumatic delivery system are given in Leonardelli et al. (2015). The nozzle directed the air‐puff to the outer canthus of the left eye from a distance of approximately 2–4 cm, individually adjusted to evoke a visible blink after each delivery, but without discomfort. The arrival time of the air‐puff was calibrated off‐line using a microphone and was relatively insensitive to the distance of the nozzle over a limited range (∼1 ms/cm). Subjects received four contiguous 12 min blocks of stimulation. To equate the task to the baseline phase of a previously validated eyeblink conditioning paradigm (Cheng et al. 2008), each block constituted 200 trials: 140 trials of air‐puffs, 50 trials of a 550 ms binaural tone (2800 Hz) and 10 paired trials with the tone co‐terminated with air‐puff delivery; trial order was randomized in sets of 20. A total of 600 air‐puff trials were recorded per subject. Every trial began with a random wait of 1–2.5 s to avoid habituation and anticipation; inter‐stimulus intervals averaged to 3.6 s.
To understand the relationship between neck muscle and OP‐MEG activity, two additional blocks, with surface electromyography (EMG) recorded by MEG‐compatible electrodes available on the CTF275 MEG in the Nottingham MSR, were administered in one subject (subject 3) on a separate day. EMG electrode pairs were placed over the bilateral cervical splenius capitis (SPL), the primary muscles activated during neck extension, based on Sommerich et al. (2000). Eleven posterior OPM sensors were used in this recording.
OP‐MEG data collection
The OP‐MEG data were digitized at a sampling rate of 1200 Hz, using a 16‐bit digital acquisition (DAQ) system (National Instruments, Austin, TX, USA) controlled by custom‐written software in LabVIEW (National Instruments). The air‐puff trigger signals were also acquired through the same DAQ system and sent to both the OPM and CTF MEG (during sessions with concurrent EMG) data acquisition PCs to synchronize air‐puff triggers, OP‐MEG and EMG data.
Data analysis
All of the data analysis was performed using SPM12 within the MATLAB environment (Release 2014b, The Mathworks Inc., Natick, MA, USA).
OP‐MEG data pre‐processing
OP‐MEG data were filtered between 5 and 80 Hz (or 0–200 Hz for eyeblink analysis, explained in more detail below) and each trial epoched between −1000 and +1000 ms relative to air‐puff onset. Because OPMs are configured as magnetometers (as distinct from gradiometers which are used in many cryogenic MEG systems), they are susceptible to increased environmental interference. We mitigated interference by constructing virtual gradiometers, which linearly regress the signal recorded by the reference array from the signal recorded at the scalp array (Fife et al. 1999; Boto et al. 2017). Thereafter, data were concatenated across blocks and all trials of data were ranked according to signal variance. Trials with variances higher than [median + 3 × median absolute deviation] were rejected (Leys et al. 2013). For the evoked response analysis, the remaining trials (548, 588 and 585 trials with air‐puff stimulation, for subject 1, 2 and 3 respectively) were baseline corrected to the mean of the window 50 ms prior to stimulus onset and then averaged. Subject‐specific early and late peaks were identified through global field power amplitudes. Paired Student's t test was used to analyse the changes of amplitudes between baseline and evoked responses; P < 0.05 was considered significant.
Spectral analysis
For induced spectral power changes, single trial time–frequency (TF) decompositions in sensor space were calculated for each subject using a Morlet wavelet transform (Tallon‐Baudry et al. 1998) and then averaged across trials and the power of the evoked responses subtracted out. The wavelet transform was calculated for each time point between −1000 and +1000 ms, with 76 scale bins corresponding to frequencies between 5 and 80 Hz. For each trial and frequency, the mean power of the interval from 50 ms before stimulus onset until stimulus presentation was considered as a baseline level. The power change in each frequency band post‐stimulus was expressed as the relative percentage change from the pre‐stimulus baseline.
Eyeblink detection
We identified eyeblink responses from the infra‐orbital OPM sensors using the following pipeline: we began with data filtered between 0 and 200 Hz. First, a notch filter at 50 Hz was applied to remove power line noise. Second, a high pass filter at 25 Hz and then a low pass filter at 80 Hz were used. Thereafter, we performed full wave rectification and a final low pass filtering at 20 Hz. A blink peak was identified by the highest amplitude in a trial. For data presentation only, we averaged across 10 consecutive trials.
EMG data analysis
EMG Data were high‐passed filtered at 40 Hz and rectified. Data were then epoched and concatenated as had been performed for the OP‐MEG data. Both average waveforms and time–frequency decompositions were examined and compared with OP‐MEG data.
Comparing OP‐MEG to eyeblink and EMG data
We examined the trial‐by‐trial temporal correspondence between the activity of OP‐MEG and non‐neural electrical sources, including eyeblinks and muscle potentials, using Pearson's r‐values (Yuval‐Greenberg et al. 2008). The latency of the maximal power of 5–80 Hz OP‐MEG time–frequency spectrum was computed for each trial and then correlated with peak blink latency. The relationships between OP‐MEG and EMG peak latencies as well as amplitudes were also determined. In addition, EMG and OP‐MEG trials were sorted in order of the latency of peak EMG, to further inspect the connection between these two types of data.
OP‐MEG source localization
We evaluated the locus of the average evoked response using a dipole fit analysis and the induced power change using a beamformer. In both cases the volume conductor model was the Nolte single shell model (Nolte, 2003), implemented in SPM12, using the scalp boundary from the individual T1‐weighted MRI.
Dipole fitting
We reconstructed sources of the evoked field data for each subject using the SPM implementation of equivalent current dipole fitting (Kiebel et al. 2008). In brief, the inversion scheme assigned initial means and variances of dipole positions and moments (also called ‘priors’). The final dipole locations and moments were optimized using variational free energy (Friston et al. 2007; Penny, 2012; López et al. 2014). Free energy quantifies a model's ability to explain the same data (by maximizing the likelihood, similar to other dipole fitting routines) while penalizing excessive optimization (heuristically speaking, a complexity penalty). Moreover, models in which the sources have different prior locations can be compared using free energy. This is particularly useful for comparing different anatomical models of the same data (e.g. is the source more likely to have arisen from the cerebellum or the neck muscles?)
We specified the initial mean locations of six single dipole models based on the literature: (1) right somatosensory cortex (S1), face area, (2) left S1, face area (Nevalainen et al. 2006), (3) right cerebellum (in lobule VI), (4) left cerebellum, lobule VI (Cheng et al. 2008), (5) right and (6) left medial parieto‐occipital areas. Model 5 and 6 were used because these areas are not only spatially close to the cerebellum but also known to present blink‐related activity (Bardouille et al. 2006; Liu et al. 2017). We also tested if the evoked responses might have originated from non‐neural sources (i.e. posterior neck muscles) using two additional initial mean locations at the right and left posterior neck. The standard deviation of each prior dipole location was set to 10 mm; the mean and standard deviation of each prior moment were assigned as 0 and 10 nA m, respectively. To avoid local maxima, 50 iterations, with starting locations and orientations (i.e. the means and standard deviations of prior locations and moments) randomly sampled from prior distributions, were carried out for each model in each subject (50 × 6 = 300 iterations in each subject). For each subject, we used the model parameters corresponding to the highest free energy value across all iterations. The maximal free energy values were then averaged across subjects.
Beamforming
We used the scalar version of a linear constrained minimum variance beamformer algorithm implemented in the DAISS toolbox for SPM (https://github.com/spm/DAiSS) to localize the source of induced spectral power changes. Two different covariance windows were chosen according to observed sensor level responses (Fig. 4). We first used a covariance window of 5–80 Hz and a time window of −50 to +125 ms and contrasted the 75–125 ms post‐stimulus period with a pre‐stimulus period between −50 and 0 ms. Second, we used a covariance window of 5–30 Hz and a time window spanning −400 to +900 ms and contrasted an individually based 400 ms post‐stimulus peak power period with a pre‐stimulus baseline between −400 and 0 ms. The regularization rate λ was set to be 0 (i.e. unregularized) (Barnes et al. 2004). The source orientation was set in the direction of maximal power. The reconstruction grid spacing was 10 mm.
Results
Sensor level responses
We looked at the average evoked response to air‐puff stimulation from the cerebellar OPM sensors and from the sensors positioned over the contralateral somatosensory cortex. Figure 2 A shows the average evoked response measured in posterior sensors (left sensors: blue dotted curves, right sensors: orange continuous curves) for the three subjects. Two main peaks were observed across subjects at around 50–60 ms and 85–115 ms. The field patterns observed at these peaks were qualitatively dipolar (Fig. 2 A middle panel). For both early and late responses, a paired t test showed that peak field strengths were significantly different from those during the baseline time windows in the majority of sensors (for subject 1, 16/19 channels for the early peak, 11/19 for the late peak; for subject 2, 15/18 and 12/18, respectively, and for subject 3, 8/13 for both early and late peaks). There was a slight latency difference (approx. 2 ms on average) between positive and negative going extrema (e.g. subject 2, Fig. 2 A upper panel), indicating a more complex source distribution. This small offset was not considered when statistically comparing the peak field strengths. We also observed two response peaks from sensors close to the primary somatosensory cortex (anterior sensors: green continuous curves, posterior: blue dashed curves, Fig. 2 B). For each subject, the earliest distinct somatosensory evoked response peaked at 40–50 ms post‐stimulus, compatible with the p45m response to facial tactile stimuli (Nevalainen et al. 2006).
The latency and shape of the blink trace recorded from infra‐orbital sensors were dissimilar to the cerebellar evoked responses (Fig. 2 C). Although the late peak of the OP‐MEG evoked responses (Fig. 3 A upper, 86 ms) was temporally close to average EMG activity peak (Fig. 3 A lower, 93 ms), several other features of cerebellar evoked responses were clearly different from muscle activity. We sorted trials by the latency of peak EMG and showed that peak EMG latencies (Fig. 3 B, left panel) were approximately uniformly distributed across the epoch. The EMG peaks seemed to temporally correlate with enhanced negativity of the OP‐MEG, regardless of the polarity of the evoked response, in some sensors (6 out of 11, two examples shown in Fig. 3 B, middle and right panels). For example, peak EMG coupled with increased negativity in both OPM channel 1 and 2 (Fig. 3 B, middle and right panels), while their evoked responses were opposite in polarity (Fig. 3 A, upper panel). Importantly, the EMG–MEG correspondence was only observable outside the time window of evoked responses (i.e. before air‐puff stimulation and after 150 ms). We correlated EMG and OP‐MEG (negative) peak latencies separately for trials with EMG peaking before and after 150 ms. We found only trials peaking after 150 ms had a significant but weak correlation (Fig. 3 C; trials with EMG peaking after 150 ms: r = 0.19, P = 0.01; trials peaking before 150 ms: r = 0.12, P = 0.16). No correlation between EMG and OP‐MEG amplitude was found at the latency of the late evoked component (r = −0.06, P = 0.30) (Fig. 3 D).
We also looked for induced spectral changes in the cerebellar sensors. Figure 4 shows the average time–frequency spectrograms (as percentage change of power from baseline) for the two sensors with the largest power change in each subject. Two types of induced responses can be observed. One was a transiently increased broadband power, peaking at ∼100 ms post‐air‐puff contact (Fig. 4 A, left column). The other was an enhanced activity at ∼10–30 Hz during 100–900 ms post‐air‐puff contact (Fig. 4 A, right column). The correlation across trials between the latencies of the maximal induced power changes and of peak blinks was only significant in subject 2 (P = 0.03) and was very weak (r = −0.088; r 2 = 0.0078, which meant that less than 1% of the variance is explained by the linear model of blink and MEG peak latency) (Fig. 5 A middle column). However, the time–frequency spectra of EMG show a transient enhanced gamma band power at ∼100 ms (Fig. 5 B), which was similar to the transient increased broadband response observed in the OP‐MEG (cf. Fig. 4 A, left column).
Source reconstruction
Evoked responses
Figure 6 shows the source reconstruction results of the early and late evoked responses. Figure 6 A compares the mean free energy values (averaged across subjects), for six models initiated at different source locations, for the early (peak latency ± 2 ms, respectively yielding subject‐specific windows of 48–52, 50–54 and 60–64 ms; top panel) and late responses (82–86, 90–93, and 115–119 ms; bottom panel). Both cerebellar priors were significantly better than the other models (ΔF > 3; as F approximates the log model evidence, a positive difference of 3 means the preferable model is about 20 times more likely). The left (ipsilateral) cerebellum lobule VI had the highest model evidence for both peaks; although this model was not significantly better than the model of a source in the right cerebellum (ΔF = 0.8 for early and ΔF = 2.2 for late peaks). Figure 6 B shows the fitted source locations for subject‐specific, early and late time windows. The source localizations were within the cerebellum or the brainstem/cerebellar peduncle adjacent to the cerebellum. Table 1 shows the MNI coordinates and anatomical labels of each fit.
Table 1.
Early | Late | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MNI coordinates | Dipole moments | MNI coordinates | Dipole moments | |||||||||||
X | Y | Z | X | Y | Z | X | Y | Z | X | Y | Z | |||
S1 | R VIII | 17.95 | −72.7 | −55 | 2.09 | 4.51 | −30.63 | R VIII | 12.34 | −71.1 | −52.1 | −3.91 | −9.75 | −7.43 |
S2 | L IX | −5.76 | −48.80 | −58.98 | 11.42 | −26.85 | 2.95 | R pons | 8.4 | −38.07 | −43.62 | −5.43 | 23.59 | 5.53 |
S3 | R pons | 2.32 | −40.85 | −21.7 | −15.41 | 27.88 | −25.32 | L deep nu | −14 | −64.63 | −35.2 | 4.50 | −16.05 | −2.83 |
Location labels were based on Diedrichsen et al. (2009). Latin numerals denote the assignment to lobules.
Dipole locations converged into the cerebellum even when using priors in the medial parieto‐occipital areas (model 5 and 6, see Fig. 6 C). We also undertook additional single dipole fitting using extra‐cranial priors at the posterior neck, approximating the SPL muscle, and found similar results (Fig. 6 D).
Induced responses
In order to locate the two types of sensor‐level induced power changes, we performed the beamforming analysis with two different covariance windows. For the transient broadband response, a window covering a 5–80 Hz frequency band and a time range of −50 to +125 ms was used, and we contrasted the power between time windows of +75 to +125 ms and −50 to 0 ms. For the response in alpha and beta range, a window covering a 5–30 Hz frequency band and a time range of −400 to +900 ms was used, and we contrasted an individual peak‐based 400 ms poststimulus period (500–900 ms for subject 1, 100–500 ms for subject 2 and 3, see Fig. 4 A) with a pre‐stimulus baseline between −400 and 0 ms. For the broadband component, the global maxima were located at the posterior neck. For the induced response in alpha and beta bands, the sources were localized in the medial occipital area. Table 2 shows the MNI coordinates of the global maxima.
Table 2.
Broadband MNI coordinates | Alpha and beta MNI coordinates | |||||||
---|---|---|---|---|---|---|---|---|
X | Y | Z | X | Y | Z | |||
S1 | L neck | −1.25 | −68.34 | −70.23 | R Occipital | 0.05 | −90.59 | −7.60 |
S2 | L neck | −5.81 | −41.18 | −63.58 | R Occipital | 29.86 | −56.58 | 6.79 |
S3 | R neck | 12.55 | −88.93 | −63.53 | R Occipital | 21.71 | −68.16 | 1.61 |
Discussion
We have demonstrated that a small OPM array with less than 20 sensors can detect cerebellar evoked responses during unconditioned eyeblinks elicited by brief air‐puffs. The evoked responses had early (∼50 ms) and late components (∼90–110 ms). The source localization of these evoked responses was in the ipsilateral cerebellum, generally consistent with previous neural recordings in animals and fMRI in humans.
MEG sensors can most readily detect signals when neuron populations aligned in parallel and oriented tangentially to the overlying skull fire synchronously (i.e. ‘open‐field neurons’). The mammalian cerebellum is characterized by extensive and fine‐scale foliation and has a patchy, fractured spatial organization of inputs (Tesche & Karhu, 1997). So it is likely a proportion of concurrent electric currents will cancel each other out due to opposite orientations (i.e. ‘close‐field neurons’), similar to what has been observed in the visual cortex (Vanegas et al. 2013). As a result, cerebellar MEG signals are expected to be considerably smaller, if not undetectable, compared to neocortical signals. In fact, this was one of the main reasons that cerebellar activity used to be considered unobtainable using MEG. However, realistic simulations and experimental data support that, though challenging, sources with this kind of close‐field neuronal organization can be identified in MEG (Hashimoto et al. 2003; Attal & Schwartz, 2013; Krishnaswamy et al. 2017). Presumably, by minimizing sensor‐to‐brain distances and co‐registration errors, OP‐MEG technology should enhance the detectability of even these weak signals, and our results provided empirical evidence supporting this assumption.
In the small number of published MEG studies, cerebellar activation to somatosensory stimuli has been identified by either using a priori assumptions of an equivalent current dipole in the cerebellum (Tesche & Karhu, 1997, 2000) or by using a beamforming source reconstruction (Hashimoto et al. 2003). Hashimoto et al. (2003) showed a four‐component response in the cerebellum following electrical stimulation of the median nerve, and the authors made a putative assignment of these peaks to different cerebellar inputs. The Hashimoto study showed robust source‐level images, predominantly localizing to ipsilateral medial cerebellum, but was based on 10,000 trials. By contrast, our results are apparent at sensor level and are based on 550–580 trials per participant. We expect that a further reduction in required trials could be achieved by the bespoke design of a cerebellar helmet, to both increase sensor numbers and optimize their locations to further increase signal‐to‐noise.
Due to the nature of the eyeblink paradigm, there were eye and eyelid movements in almost every trial. We thus examined in detail the relationship between infra‐orbital blink signals and OP‐MEG data to understand if ocular sources might contribute to the MEG sensor‐level activity (even though artefacts from the corneo‐retinal dipole and extra‐orbital muscles have been shown to be highly focal and limited to fronto‐central sensors in the MEG; Carl et al. 2012; Muthukumaraswamy, 2013). We found that eyeblink occurred relatively late (∼100–140 ms) after stimulus onset (Fig. 2 C) and, importantly, peaked after the later cerebellar component for each subject. Blink is therefore an improbable source of these evoked responses. On a trial‐by‐trial basis, we found no or only a very weak temporal correlation between the latencies of the maximal spectral power changes and blinks (Fig. 5 A). Thus, the induced responses were also not likely to be products of blinks.
Another source of non‐neural artefact to be considered is neck muscle, because it is near the cerebellum and a sudden air‐puff does lead to some reflex head motion, visible in early acclimatization trials. However, the evoked responses are unlikely to be caused by muscle activity, as dipole fits converged to the cerebellum even when using posterior neck priors (Fig. 6 D). A weak temporal correlation (Pearson r = 0.19, P = 0.01) between EMG and OP‐MEG activity broke down during the time window of evoked responses (r = 0.12, P = 0.16; Fig. 3 C). Further, there was no correlation between the amplitude of the peak surface EMG and the OP‐MEG response (r = −0.06, P = 0.30; Fig. 3 D). Regarding the induced responses, the time–frequency spectra of neck muscle EMG (Fig. 5 B) revealed a transient broadband component at ∼100 ms and 40–80 Hz, whose time and frequency features resemble the broadband induced response in the OP‐MEG. Beamforming analysis also localized the source of this transient enhancement of gamma band at the posterior neck. We thus conclude that this broadband induced response was likely to be due to muscle artefacts.
To our knowledge, this is the first MEG study examining the neural response due to the unconditioned stimulus (US, i.e. air‐puffs) in an eyeblink conditioning paradigm. Being a model system for cerebellar learning, the neural circuits of both unconditioned and conditioned blink responses have been extensively investigated in animals. In untrained rodents, single‐unit recordings from Purkinje cells in ipsilateral cerebellar cortical lobule VI show that air‐puffs elicit climbing fibre inputs, with high probability, peaking around 15–50 ms post‐stimulus (Mostofi et al. 2010; Ohmae & Medina, 2015). Importantly, the excitation of the very powerful climbing fibre–Purkinje cell synapse, simultaneously activating the dendrites of a spatially aligned set of Purkinje cells, has been considered to be the most probable source for a strong open field detected by MEG recordings (Tesche & Karhu, 1997). According to local field potential recordings in animal models, the US reaches the cerebellum first via an early mossy fibre response and then the aforementioned climbing fibre response (Hesslow, 1994; Mostofi et al. 2010). Our OP‐MEG evoked responses showed two peaks, the first tightly clustered around 50–60 ms while the second occurred 80–110 ms post‐puff with significant inter‐individual differences in latency. These first human data are thus broadly consistent with the animal literature, and the climbing fibre signal might contribute to the early 50 ms response. Previously, similar qualitative features have been seen in human MEG responses to simple somatosensory input, including multiple components (Tesche & Karhu, 2000; Hashimoto et al. 2003) and inter‐individual latency variability (Tesche & Karhu, 1997). Hashimoto et al. speculated that a component at 50–70 ms was driven by the median‐nerve‐induced activation of climbing fibres.
Although the inversion scheme suggested the left (ipsilateral) lobule VI was the best fitting single‐dipole model of both evoked responses, it should be noted that the best fits located close to the midline (see Table 1), more medial in all three subjects than the lobule VI, the location expected from the literature (Dimitrova et al. 2002; Cheng et al. 2008; Thurling et al. 2015). Besides, for both the early and late peaks of the evoked field, the differences in free energy between single dipoles in the right and left cerebellum lobule VI were small (∆F < 3, Fig. 6 A). One potential cause of this finding is that although the ipsilateral lobule VI is the dominant neuronal source of the US signal, it is not the only cerebellar focus being activated by it. Concurrent (but weaker) neuronal activation to US stimuli has been found in the contralateral lobule VI, bilateral lobule VIIb/Crus I/VIIIa (the posterior region of the hemisphere) as well as bilateral deep nuclei (Dimitrova et al. 2002; Mostofi et al. 2010; Thurling et al. 2015), so that a two‐ or multiple‐dipole model might be more accurate. When fitting the evoked fields with two‐dipole priors, the majority of best fits were indeed paired bilateral cerebellar sources (figure not shown here). These results support the hypothesis of bilateral, and maybe multi‐focus, activation in the cerebellum by unilateral air‐puff stimulation. This said, we admit the current results cannot conclusively locate the sources at a resolution of individual cerebellar lobules (Schmahmann et al. 1999).
In this proof‐of‐principle study, we also searched for induced responses to air‐puff stimulation. At the sensor level, two types of induced responses were observed: a brief increased broadband power at ∼100 ms and an increased power in a lower‐frequency range (10–30 Hz) between approximately 100 and 900 ms. However, as has been mentioned, the source of the former component was found to be outside the skull and likely to be caused by neck muscle activity. While we could not observe any overt head motion, the head was freely supported, with neck muscles activated and it is possible that reflex responses to the air‐puff stimulus caused this effect. On the other hand, the alpha and beta band responses were located in the medial occipital area. It is possible that these lower‐frequency components reflect neural responses to the transient changes of visual input during blinks, as has been reported previously (Bardouille et al. 2006; Liu et al. 2017). However, further studies will be needed to confirm the nature of this induced lower band response.
The number of OPM sensors available has limited our current tests with dipole localization accuracy (and detectability) decreasing sharply in regions outside the sensor coverage (Mosher et al. 1993). Source localization would thus likely benefit from a denser and spatially extended sensor coverage, especially given the relatively greater depth of the cerebellum, its complex architecture, and the diffuse spatial signature seen in the evoked responses (see the field maps in Fig. 2 A, middle panel). With the next generation of smaller and lighter OPM sensors, we expect to design whole‐head helmets/caps to address this issue. Additionally, it would be useful to design helmets that allow sensors to be placed over the upper neck to provide greater coverage of the inferior cerebellum, which was just below the lower margin covered by the current set‐up. We are also planning to perform identical cerebellar measurements using both whole‐head OP‐MEG and SQUID‐MEG systems, which will provide a fair comparison regarding signal magnitudes and source localization. At the moment we believe such a direct comparison would unfairly prejudice the relatively low spatial resolution available to us, with less than 20 OPM sensors. Finally, to give confidence in the identities and localizations of our findings, we intend to extend our studies to include classical conditioning and extinction of the eyeblink and thus aim to track the predicted changes in the responses to the unconditioned and conditioned stimuli across the learning and extinction phases (Ohmae & Medina, 2015).
Conclusion
We have demonstrated an OP‐MEG system that can be used to study the electrophysiology of the human cerebellum. The similarities between human MEG and animal field potential data in this proof‐of‐principle task offer promise for future studies to advance our understanding of cerebellar function through non‐invasive electrophysiology in humans. Possessing sufficient signal detectability and being wearable, and potentially moveable, we expect the OP‐MEG system to be a powerful tool in the investigation of cerebellar functions in both motor and cognitive tasks (Sokolov et al. 2017; Boto et al. 2018; Tierney et al. 2018). This OP‐MEG system also has the capacity to fill the ‘white regions’ (Niedermeyer, 2004) of the map of clinical electrophysiology in the cerebellum, with impacts on diseases including movement disorders (Bostan & Strick, 2018), mental disorders (Romer et al. 2018) and dementia (Fyfe, 2016), to name a few.
Additional information
Competing interests
This work was funded by a Wellcome award which involves a collaboration agreement with QuSpin. QuSpin built the sensors used here and advised on the system design and operation, but played no part in the subsequent measurements or data analysis.
Author contributions
C.L., G.R.B. and R.C.M. contributed to the conceptual design of the experimental work, acquisition and interpretation of the data, and drafting/revising the manuscript. T.M.T., N.H. and E.B. contributed to the acquisition and interpretation of the data and assisted with the manuscript revisions. J.L., S.B., R.B. and M.J.B. contributed to the analysis, interpretation of the data and assisted with the manuscript revisions. All authors have read and approved the final version of this manuscript and agree to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved. All persons designated as authors qualify for authorship, and all those who qualify for authorship are listed.
Funding
C.L. was funded by a BBSRC research grant (BB/M009645/1) and by Wellcome grant WT212422. This work was also supported by a Wellcome collaborative award to G.R.B., M.J.B. and R.B. (203257/Z/16/Z, 203257/B/16/Z). The WCHN is supported by a strategic award from Wellcome (091593/Z/10/Z). R.C.M. was funded by a Royal Society Leverhulme Senior Fellowship and by Wellcome grant WT212422.
Acknowledgements
We thank Uta Noppeney for use of the pneumatic controller to deliver air‐puffs and Jose David Lopez for helpful discussion.
Biography
Chin‐Hsuan Lin is a post‐doctoral researcher at the School of Psychology, University of Birmingham. She completed her training as a neurologist at National Taiwan University Hospital before relocating to Imperial College London for her PhD in bioengineering. She is interested in the neural mechanisms of motor and cognitive processing in the cerebellum. Her current work focuses on the development and application of non‐invasive electrophysiology to study the human cerebro‐cerebellar circuits.
Edited by: David Wyllie & Richard Carson
Preprint publication This article was first published as a preprint: Lin C, Tierney TM, Holmes N, Boto E, Leggett J, Bestmann S, Bowtell R, Brookes MJ, Miall RC & Barnes GR (2018). Using optically‐pumped magnetometers to measure magnetoencephalographic signals in the human cerebellum. bioRxiv doi: 10.1101/425447
References
- Attal Y & Schwartz D (2013). Assessment of subcortical source localization using deep brain activity imaging model with minimum norm operators: A MEG study. PLoS One 8, e59856. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bardouille T, Picton TW & Ross B (2006). Correlates of eye blinking as determined by synthetic aperture magnetometry. Clin Neurophysiol 117, 952–958. [DOI] [PubMed] [Google Scholar]
- Barnes GR, Hillebrand A, Fawcett IP & Singh KD (2004). Realistic spatial sampling for MEG beamformer images. Hum Brain Mapp 23, 120–127. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bostan AC & Strick PL (2018). The basal ganglia and the cerebellum: Nodes in an integrated network. Nat Rev Neurosci 19, 338–350. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Boto E, Holmes N, Leggett J, Roberts G, Shah V, Meyer SS, Muñoz LD, Mullinger KJ, Tierney TM, Bestmann S, Barnes GR, Bowtell R & Brookes MJ (2018). Moving magnetoencephalography towards real‐world applications with a wearable system. Nature 555, 657–661. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Boto E, Meyer SS, Shah V, Alem O, Knappe S, Kruger P, Fromhold TM, Lim M, Glover PM, Morris PG, Bowtell R, Barnes GR & Brookes MJ (2017). A new generation of magnetoencephalography: Room temperature measurements using optically‐pumped magnetometers. Neuroimage 149, 404–414. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Buckner RL (2013). The cerebellum and cognitive function: 25 years of insight from anatomy and neuroimaging. Neuron 80, 807–815. [DOI] [PubMed] [Google Scholar]
- Carl C, Açik A, König P, Engel AK & Hipp JF (2012). The saccadic spike artifact in MEG. Neuroimage 59, 1657–1667. [DOI] [PubMed] [Google Scholar]
- Cheng DT, Disterhoft JF, Power JM, Ellis DA & Desmond JE (2008). Neural substrates underlying human delay and trace eyeblink conditioning. Proc Natl Acad Sci U S A 105, 8108–8113. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Dalal SS, Osipova D, Bertrand O & Jerbi K (2013). Oscillatory activity of the human cerebellum: The intracranial electrocerebellogram revisited. Neurosci Biobehav Rev 37, 585–593. [DOI] [PubMed] [Google Scholar]
- Diedrichsen J, Balsters JH, Flavell J, Cussans E & Ramnani N (2009). A probabilistic MR atlas of the human cerebellum. Neuroimage 46, 39–46. [DOI] [PubMed] [Google Scholar]
- Dimitrova A, Weber J, Maschke M, Elles HG, Kolb FP, Forsting M, Diener HC & Timmann D (2002). Eyeblink‐related areas in human cerebellum as shown by fMRI. Hum Brain Mapp 17, 100–115. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Dupont‐Roc J, Haroche S & Cohen‐Tannoudji C (1969). Detection of very weak magnetic fields (10−9 gauss) by 87Rb zero‐field level crossing resonances. Phys Lett A 28, 638–639. [Google Scholar]
- Fife AA, Vrba J, Robinson SE, Anderson G, Betts K & Burbank MB (1999). Synthetic gradiometer systems for MEG. IEEE Trans Appl Supercond 9, 4063–4068. [Google Scholar]
- Freeman JH & Steinmetz AB (2011). Neural circuitry and plasticity mechanisms underlying delay eyeblink conditioning. Learn Mem 18, 666–677. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Friston K, Mattout J, Trujillo‐Barreto N, Ashburner J & Penny W (2007). Variational free energy and the Laplace approximation. Neuroimage 34, 220–234. [DOI] [PubMed] [Google Scholar]
- Fyfe I (2016). Dementia: Cerebellar atrophy has disease‐specific patterns. Nat Rev Neurol 12, 188. [DOI] [PubMed] [Google Scholar]
- Gerloff C, Altenmüller E & Dichgans J (1996). Disintegration and reorganization of cortical motor processing in two patients with cerebellar stroke. Electroencephalogr Clin Neurophysiol 98, 59–68. [DOI] [PubMed] [Google Scholar]
- Gerwig M, Kolb FP & Timmann D (2007). The involvement of the human cerebellum in eyeblink conditioning. Cerebellum 6, 38–57. [DOI] [PubMed] [Google Scholar]
- Glickstein M, Sultan F & Voogd J (2011). Functional localization in the cerebellum. Cortex 47, 59–80. [DOI] [PubMed] [Google Scholar]
- Gross J, Timmermann L, Kujala J, Dirks M, Schmitz F, Salmelin R & Schnitzler A (2002). The neural basis of intermittent motor control in humans. Proc Natl Acad Sci U S A 99, 2299–2302. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hashimoto I, Kimura T, Tanosaki M, Iguchi Y & Sekihara K (2003). Muscle afferent inputs from the hand activate human cerebellum sequentially through parallel and climbing fiber systems. Clin Neurophysiol 114, 2107–2117. [DOI] [PubMed] [Google Scholar]
- Hesslow G (1994). Correspondence between climbing fibre input and motor output in eyeblink related areas in cat cerebellar cortex. J Physiol 476, 229–244. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Holmes N, Leggett J, Boto E, Roberts G, Hill RM, Tierney TM, Shah V, Barnes GR, Brookes MJ & Bowtell R (2018). A bi‐planar coil system for nulling background magnetic fields in scalp mounted magnetoencephalography. Neuroimage 181, 760–774. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Houck JM, Martin T, Bish JP, Moses SN, Woodruff CC, Kičić D & Tesche CD (2007). Early cerebellar activation predicts response time. Int Congr Series 1300, 413–416. [Google Scholar]
- Iivanainen J, Zetter R, Grön M, Hakkarainen K & Parkkonen L (2019). On‐scalp MEG system utilizing an actively shielded array of optically‐pumped magnetometers. Neuroimage 194, 244–258. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Jerbi K, Lachaux J‐P, N'Diaye K, Pantazis D, Leahy RM, Garnero L & Baillet S (2007). Coherent neural representation of hand speed in humans revealed by MEG imaging. Proc Natl Acad Sci U S A 104, 7676–7681. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kiebel SJ, Daunizeau J, Phillips C & Friston KJ (2008). Variational Bayesian inversion of the equivalent current dipole model in EEG/MEG. Neuroimage 39, 728–741. [DOI] [PubMed] [Google Scholar]
- Krishnaswamy P, Obregon‐Henao G, Ahveninen J, Khan S, Babadi B, Iglesias JE, Hämäläinen MS & Purdon PL (2017). Sparsity enables estimation of both subcortical and cortical activity from MEG and EEG. Proc Natl Acad Sci U S A 114, E10465–E10474. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lascano AM, Lemkaddem A, Granziera C, Korff CM, Boex C, Jenny B, Schmitt‐Mechelke T, Thiran JP, Garibotto V, Vargas MI, Schaller K, Seeck M & Vulliemoz S (2013). Tracking the source of cerebellar epilepsy: Hemifacial seizures associated with cerebellar cortical dysplasia. Epilepsy Res 105, 245–249. [DOI] [PubMed] [Google Scholar]
- Leonardelli E, Braun C, Weisz N, Lithari C, Occelli V & Zampini M (2015). Prestimulus oscillatory alpha power and connectivity patterns predispose perceptual integration of an audio and a tactile stimulus. Hum Brain Mapp 36, 3486–3498. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Leys C, Ley C, Klein O, Bernard P & Licata L (2013). Detecting outliers: Do not use standard deviation around the mean, use absolute deviation around the median. J Exp Soc Psychol 49, 764–766. [Google Scholar]
- Liu CC, Ghosh Hajra S, Cheung TPL, Song X & D'Arcy RCN (2017). Spontaneous blinks activate the precuneus: Characterizing blink‐related oscillations using magnetoencephalography. Front Hum Neurosci 11, 489. [DOI] [PMC free article] [PubMed] [Google Scholar]
- López JD, Litvak V, Espinosa JJ, Friston K & Barnes GR (2014). Algorithmic procedures for Bayesian MEG/EEG source reconstruction in SPM. Neuroimage 84, 476–487. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Martin T, Houck JM, Bish JP, Kičić D, Woodruff CC, Moses SN, Lee DC & Tesche CD (2006). MEG reveals different contributions of somatomotor cortex and cerebellum to simple reaction time after temporally structured cues. Hum Brain Mapp 27, 552–561. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Meyer SS, Bonaiuto J, Lim M, Rossiter H, Waters S, Bradbury D, Bestmann S, Brookes M, Callaghan MF, Weiskopf N & Barnes GR (2017). Flexible head‐casts for high spatial precision MEG. J Neurosci Methods 276, 38–45. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Mosher JC, Spencer ME, Leahy RM & Lewis PS (1993). Error bounds for EEG and MEG dipole source localization. Electroencephalogr Clin Neurophysiol 86, 303–321. [DOI] [PubMed] [Google Scholar]
- Mostofi A, Holtzman T, Grout AS, Yeo CH & Edgley SA (2010). Electrophysiological localization of eyeblink‐related microzones in rabbit cerebellar cortex. J Neurosci 30, 8920–8934. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Muthukumaraswamy SD (2013). High‐frequency brain activity and muscle artifacts in MEG/EEG: a review and recommendations. Front Hum Neurosci 7, 138. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Muthukumaraswamy SD, Johnson BW, Gaetz WC & Cheyne DO (2006). Neural processing of observed oro‐facial movements reflects multiple action encoding strategies in the human brain. Brain Res 1071, 105–112. [DOI] [PubMed] [Google Scholar]
- Muthukumaraswamy SD, Johnson BW & Hamm JP (2003). A high density ERP comparison of mental rotation and mental size transformation. Brain Cogn 52, 271–280. [DOI] [PubMed] [Google Scholar]
- Nevalainen P, Ramstad R, Isotalo E, Haapanen ML & Lauronen L (2006). Trigeminal somatosensory evoked magnetic fields to tactile stimulation. Clin Neurophysiol 117, 2007–2015. [DOI] [PubMed] [Google Scholar]
- Niedermeyer E (2004). The electrocerebellogram. Clin EEG Neurosci 35, 112–115. [DOI] [PubMed] [Google Scholar]
- Nolte G (2003). The magnetic lead field theorem in the quasi‐static approximation and its use for magnetoenchephalography forward calculation in realistic volume conductors. Phys Med Biol 48, 3637–3652. [DOI] [PubMed] [Google Scholar]
- Ohmae S & Medina JF (2015). Climbing fibers encode a temporal‐difference prediction error during cerebellar learning in mice. Nat Neurosci 18, 1798–1803. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Osborne J, Orton J, Alem O & Shah V (2018). Fully integrated, standalone zero field optically pumped magnetometer for biomagnetism. Proc SPIE 10548 (Steep Dispersion Engineering and Opto‐Atomic Precision Metrology XI), 105481G. 10.1117/12.2299197 [DOI]
- Penny WD (2012). Comparing dynamic causal models using AIC, BIC and free energy. Neuroimage 59, 319–330. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pollok B, Gross J, Dirks M, Timmermann L & Schnitzler A (2004). The cerebral oscillatory network of voluntary tremor. J Physiol 554, 871–878. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pollok B, Gross J, Müller K, Aschersleben G & Schnitzler A (2005). The cerebral oscillatory network associated with auditorily paced finger movements. Neuroimage 24, 646–655. [DOI] [PubMed] [Google Scholar]
- Romer AL, Knodt AR, Houts R, Brigidi BD, Moffitt TE, Caspi A & Hariri AR (2018). Structural alterations within cerebellar circuitry are associated with general liability for common mental disorders. Mol Psychiatry 23, 1084–1090. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Schmahmann JD, Doyon J, McDonald D, Holmes C, Lavoie K, Hurwitz A, Kabani N, Toga A, Evans A & Petrides M (1999). Three‐dimensional MRI atlas of the human cerebellum in proportional stereotaxic space. Neuroimage 10, 233–260. [DOI] [PubMed] [Google Scholar]
- Schmahmann JD & Sherman JC (1998). The cerebellar cognitive affective syndrome. Brain 121, 561–579. [DOI] [PubMed] [Google Scholar]
- Schnitzler A, Münks C, Butz M, Timmermann L & Gross J (2009). Synchronized brain network associated with essential tremor as revealed by magnetoencephalography. Mov Disord 24, 1629–1635. [DOI] [PubMed] [Google Scholar]
- Shah VK & Wakai RT (2013). A compact, high performance atomic magnetometer for biomedical applications. Phys Med Biol 58, 8153–8161. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sokolov AA, Miall RC & Ivry RB (2017). The cerebellum: Adaptive prediction for movement and cognition. Trends Cogn Sci 21, 313–332. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sommerich CM, Joines SMB, Hermans V & Moon SD (2000). Use of surface electromyography to estimate neck muscle activity. J Electromyogr Kinesiol 10, 377–398. [DOI] [PubMed] [Google Scholar]
- Stoodley CJ & Schmahmann JD (2009). Functional topography in the human cerebellum: A meta‐analysis of neuroimaging studies. Neuroimage 44, 489–501. [DOI] [PubMed] [Google Scholar]
- Tallon‐Baudry C, Bertrand O, Peronnet F & Pernier J (1998). Induced gamma‐band activity during the delay of a visual short‐term memory task in humans. J Neurosci 18, 4244–4254. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tass PA, Fieseler T, Dammers J, Dolan K, Morosan P, Majtanik M, Boers F, Muren A, Zilles K & Fink GR (2003). Synchronization tomography: a method for three‐dimensional localization of phase synchronized neuronal populations in the human brain using magnetoencephalography. Phys Rev Lett 90, 4. [DOI] [PubMed] [Google Scholar]
- Tesche CD & Karhu J (1997). Somatosensory evoked magnetic fields arising from sources in the human cerebellum. Brain Res 744, 23–31. [DOI] [PubMed] [Google Scholar]
- Tesche CD & Karhu JJT (2000). Anticipatory cerebellar responses during somatosensory omission in man. Hum Brain Mapp 9, 119–142. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Thurling M, Kahl F, Maderwald S, Stefanescu RM, Schlamann M, Boele H‐J, De Zeeuw CI, Diedrichsen J, Ladd ME, Koekkoek SK & Timmann D (2015). Cerebellar cortex and cerebellar nuclei are concomitantly activated during eyeblink conditioning: A 7T fMRI study in humans. J Neurosci 35, 1228–1239. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tierney TM, Holmes N, Meyer SS, Boto E, Roberts G, Leggett J, Buck S, Duque‐Muñoz L, Litvak V, Bestmann S, Baldeweg T, Bowtell R, Brookes MJ & Barnes GR (2018). Cognitive neuroscience using wearable magnetometer arrays: Non‐invasive assessment of language function. Neuroimage 181, 513–520. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Timmermann L, Gross J, Dirks M, Volkmann J, Freund HJ & Schnitzler A (2003). The cerebral oscillatory network of parkinsonian resting tremor. Brain 126, 199–212. [DOI] [PubMed] [Google Scholar]
- Todd NPM, Govender S & Colebatch JG (2018). The human electrocerebellogram (ECeG) recorded non‐invasively using scalp electrodes. Neurosci Lett 682, 124–131. [DOI] [PubMed] [Google Scholar]
- Vanegas MI, Blangero A & Kelly SP (2013). Exploiting individual primary visual cortex geometry to boost steady state visual evoked potentials. J Neural Eng 10, 036003. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Yuval‐Greenberg S, Tomer O, Keren AS, Nelken I & Deouell LY (2008). Transient induced gamma‐band response in EEG as a manifestation of miniature saccades. Neuron 58, 429–441. [DOI] [PubMed] [Google Scholar]