Published in final edited form as: Hum Factors. 2008 Apr;50(2):227–236. doi: 10.1518/001872008X250692

The Effect of Handle Friction and Inward/Outward Torque on Maximum Axial Push Force

Na Jin Seo 1, Thomas J Armstrong 2, Don B Chaffin 3, James A Ashton-Miller 4
PMCID: PMC6774193  NIHMSID: NIHMS1050692  PMID: 18516834

Abstract

Objective:

To investigate the relationship between friction, applied torque, and axial push force on cylindrical handles.

Background:

We have earlier demonstrated that subjects can exert greater contact force and torque in an ‘inward’ movement of the hand about the long axis of a gripped cylinder (wrist flexion/forearm supination) than they can in an ‘outward’ hand movement.

Method:

Twelve healthy subjects exerted anteriorly-directed maximum push forces along the long axis of aluminum and rubber handles while applying deliberate inward or outward torques, no torque (straight), and an unspecified (preferred) torque.

Results:

Axial push force was 12% greater for the rubber handle than for the aluminum handle. Subjects exerted mean torques of 1.1, 0.3, 2.5, and −2.0 Nm and axial push forces of 94, 85, 75, and 65 N for the preferred, straight, inward, and outward trials, respectively. Left to decide for themselves, subjects tended to apply inward torques, which were associated with increased axial push forces.

Conclusions:

Axial push force was limited by hand-handle coupling–not the whole body’s push strength. Subjects appeared to intuitively know that the application of an inward torque will improve their maximum axial push force. Axial push forces were least when a deliberate torque was requested, probably because high levels of torque exertions interfered with the push.

Application:

Low-friction handle decreases maximum axial push force. It should be anticipated that people will apply inward torque during maximum axial push.

Keywords: push strength, hand torque, hand biomechanics, hand ergonomics

INTRODUCTION

Significance

Many activities in work and daily living entail gripping a cylindrical object about its diameter and applying an axial force to move it from one location to another, to join it to another part, to support the body, or to propel a wheelchair. Friction produced between the hand and the handle is necessary to overcome external forces that tend to push the handle out of the hand. Slippery handles and hands sliding onto the blades of knives can cause many injuries, including lacerations and even amputation of fingers (Malker, 1991). Hose installation and pipe assembly, which are prevalent in many manufacturing, plumbing, and service jobs, are examples of a task that requires a large axial push force. Hose installation task entails grasping a rubber hose and pushing it onto a flange until the hose is tightly seated on the base of the flange. A survey study by Ebersole and Armstrong (2004) reported that hose installation tasks were consistently rated as the most physically demanding part of their job by workers in an automotive truck assembly plant. Also, it is well known that repeated exertions of high forces may cause fatigue (Rohmert, 1973; Bystrom and Fransson-Hall, 1994) and pain or injury to a worker (Armstrong et al., 1993; Bystrom and Kilbom, 1990; NRC, 1999; NRC and IOM, 2001).

Rationale

Previous investigators have studied maximum voluntary isometric push forces and maximum acceptable push forces in a standing posture (Chaffin et al. 1983; Daams, 1993; Peebles and Norris, 2003; Davis and Stubbs, 1977; Snook and Ciriello, 1991). These studies used handles that produced mechanical interference to prevent the hands from slipping, so that the full force of the body could be transferred to the work object (e.g., pushing against a wall). Though helpful in some situations, these data are not appropriate when the magnitude of a push force applied to an axial handle may be limited by friction, as illustrated in Figure 1a.

Figure 1.

Figure 1.

Top, a: Axial push force can be modeled as a sum of friction forces at the hand-handle contact, where friction force at each hand-handle contact is a product of the friction coefficient and normal force at the contact. The directions of inward and outward torque exertions and illustration of grip force (Fg) and normal force (∑ Fni) are shown. Middle, b: The handle was connected to a load cell via universal joints. Axial push force results in reaction force in the opposite direction which generates a moment about the wrist in the ulnar direction. Bottom, c: Moment about the wrist joint is reduced when there is downward force applied by the hand to a fixed handle (segmented lines). The downward force results in an upward reaction force which generates a moment about the wrist joint in the radial direction. This radially-directed moment can alleviate the ulnar-directed moment resulting from the axial force (solid lines).

It has been previously shown, both empirically and by a biomechanical model, that when the hand applies torque about the long axis of a cylindrical object in a power grip, an ‘inward’ torque (i.e., acting in a proximal-to-distal sense with respect to the fingers) resulted in 19% greater normal force on the handle, compared to an ‘outward’ torque (i.e., proximal-to-distal sense with respect to the thumb) (Seo et al., In Press). As a result, the maximum inward torque was 22% greater than the maximum outward torque. This is because skin friction produced by twisting an object in the direction the fingertips point causes flexion of the distal phalanges, and increases the normal force and, thus, torque, as described by the biomechanical model proposed in Seo et al. (In Press; 2008). Based on these findings, we hypothesized that the increased grip force when applying an inward torque would result in an increased maximum push force along a cylindrical handle (termed ‘axial push force’). Conversely, a decreased grip force from an outward torque would result in a decrease in axial push force along the long axis of a cylindrical handle.

We therefore conducted an experiment to test two hypotheses: 1) Maximum axial push force is related to friction, and 2) maximum axial push force on a cylindrical handle will increase by simultaneously applying an inward torque.

METHODS

Procedures

The independent variables in this study were handle material (aluminum or rubber), and push methods: push with an inward torque, push with an outward torque (see Figure 1a for torque directions), straight push (with no torque), and a subject-selected preferred method. Dependent variables were maximum axial push force, torque, grip force, normal force, and finger flexor muscle activities estimated by using surface EMG.

Upon their arrival at the laboratory, subjects washed and dried their hands with paper towels to eliminate possible artifacts due to contaminants. Finger flexor muscle activities were recorded using surface EMGs. One pair of surface EMG electrodes was placed over the proximal muscle belly fibers of flexor digitorum profundus (FDP) on the medial side of the forearm, approximately one-third the distance on a line from the medial epicondyle to the styloid process of ulna (Garland and Miles, 1997). Flexor digitorum superficialis (FDS) was located as recommended by Basmajian (1989), except that surface EMG electrodes were placed approximately two-thirds the distance on a line from the medial epicondyle to the center of the wrist, to minimize crosstalk from the flexor carpi radialis and flexor carpi ulnaris.

The subjects, while standing, grasped a horizontal cylindrical handle with the right hand in a power grip to exert a maximum axial push for 5 seconds (see Figure 1b). The handle height was adjusted to each subject’s standing elbow height. Subjects were allowed to freely choose a posture, e.g., lean forward, to maximize the push force (Daams, 1993). Trials were randomized, except that the preferred method was tested at the beginning and at the end of the sequence of trials. Pushes with deliberate inward or outward torques were performed at a comfortable torque level, and at 30%, 50%, and 80% of each subject’s maximum voluntary torque. For a push with a comfortable level of torque, subjects were instructed to apply whatever torque they felt comfortable during their maximum axial push exertion. For pushes with specified torques, subjects were instructed to match their torque levels to the 30%, 50%, or 80% of maximum voluntary torque displayed on a computer screen. Additionally, each subject’s maximum grip force and maximum inward and outward torque on the handle were measured. Each condition was tested twice, and data were averaged for two repetitions. A two-minute break was given between successive trials.

Apparatus

Grip force was measured using a split cylinder in which two halves of the cylinder are connected by a force gauge (Ayoub and Lo Presti, 1971; Edgren et al., 2004; Grant et al., 1992; Grant and Habes, 1993; measurement error within 7%). The split cylinder was covered with a pressure sensitive pad (Tekscan Pressure Measurement System; measurement error within 6%) that recorded normal pressure on each 5.08 by 5.08 mm sensor. The pressure sensitive pad was calibrated as specified by the manufacturer (Tekscan, Inc). Total normal force was calculated by summing forces on each pressure sensor (see Figure 1a). The pressure sensitive pad was covered with a smooth 3.5 mm-thick rubber sheet, or with a smooth 0.2 mm-thick aluminum sheet. With the pressure sensitive pad and a sheet of rubber or aluminum wrapping the split cylinder, the tested handle diameters were 57.8 and 51.2 mm for the rubber and aluminum, respectively. The handle was connected to a load cell via two universal joints to eliminate lateral forces as defined by Drury (1980). The load cell measured axial push forces and the applied torque about the handle’s long axis (measurement error .2%).

The EMG instrumentation used surface EMG electrodes (AMBU Neuroline 720 Wet Gel Ag/AgCl) and a pre-amplifier with gain of 100 and a common mode rejection ratio of 115 dB. The raw signal was converted to real time root-mean-square values using a 55 ms time constant. Among all maximum exertions, the highest EMG value was used to normalize other EMG values as a percentage of maximum voluntary contraction. The data were collected at 5 Hz. All data were averaged over 2 seconds during maximum exertions. The floor on which the subjects stood was covered with a coarse rubber mat to provide sufficient foot traction. Throughout the experiment, none of the subjects exhibited problems with foot slippage, irrespective of footwear or postures adopted during exertions.

Analysis of variance was performed using MINITAB ® Release 14 to determine whether axial push force was significantly affected by handle material, push method, torque, and gender, with a value of p = 0.05 being considered significant.

Subjects

Twelve healthy university students (6 males and 6 females, age 21–35 years, mean age: 27.0 ± 4.8) participated in the experiment. All participants were right-handed and were free of any upper extremity disorders. They gave written informed consent prior to testing. Their mean hand length was measured using the method of Garrett (1971), and was found to be 18.4 ± 0.8 cm for males and 16.8 ± 0.9 cm for females. Their mean grip strength was measured with a Jamar dynamometer with a grip span of 49 mm, and was found to be 397 ± 155 N. Male subjects’ grip strengths ranged from the 14th to 78th percentile, and female subjects’ grip strengths ranged from the 1st to 86th percentile, based on population data from Mathiowetz et al. (1985). Table 1 summarizes the subjects’ average maximum inward and outward torques, maximum grip forces and normal forces as well as FDP and FDS EMGs during maximum grip exertions on the horizontal cylindrical handles.

Table 1.

The right hand’s maximum inward and outward torque about the long axis of the handle, and maximum grip force, normal force, and finger flexor EMGs during maximum grip exertions on a cylindrical handle, for two handle materials by gender (mean ± 1 SD) (Handle diameter = 57.8 and 51.2 mm for the rubber and aluminum handle)

Gender Handle material Max inward torque1 (Nm) Max outward torque1 (Nm) Max grip force (N) Total normal force (N) FDP during max grip (%) FDS during max grip (%)
Male Aluminum 6.9 ± 1.3 −5.1 ± 1.2 222 ± 87 567 ±162 80 ± 16 80 ± 17
(n=6) Rubber 8.7 ± 2.5 −6.9 ± 1.8 222 ± 91 460 ±150 89 ± 9 84 ± 16
Female Aluminum 2.8 ± 1.7 −2.3 ± 1.1 94 ± 44 217 ±131 83 ± 14 86 ± 8
(n=6) Rubber 3.5 ± 2.1 −2.9 ± 1.7 84 ± 38 155 ±115 88 ± 10 78 ± 14
1

Inward and outward torque directions are described in Figure 1a.

RESULTS

Mean maximum axial push forces, grip forces, normal forces, torques about the long axis of the handle, and FDP and FDS EMGs are summarized in Table 2 by gender. Maximum axial push force was, on average, 12% greater for the rubber handle than for the aluminum handle (for the preferred and the straight methods, p<0.01), though grip force, FDP and FDS EMG did not vary with handle material (p>0.05). The mean maximum axial push force for males was twice that for females (p<0.01).

Table 2.

Maximum axial push force, grip force, normal force, torque about the long axis of the handle, FDP EMG and FDS EMG for all push methods and handle materials by gender (mean ± 1 SD) (Push methods include preferred push, straight push, and push with an inward/outward torque at a comfortable level, or at 30%, 50%, and 80% of the maximum torque level. Handle diameter = 57.8 and 51.2 mm for the rubber and aluminum handle, respectively)

Male (n = 6)
Handle material: Aluminum (handle diameter = 51.2 mm)
Method Push Force (N) Grip force1 (N) Normal force2 (N) Torque (Nm) FDP (%) FDS (%)
Preferred 113 ± 19 142 ± 82 328 ± 110 2.1 ± 2.0 63 ± 17 56 ± 14
Straight 107 ± 20 109 ± 51 266 ± 99 0.7 ± 0.5 63 ± 11 58 ± 12
Inward torque comf 99 ± 28 156 ± 73 380 ± 216 3.0 ± 1.5 65 ± 19 62 ± 22
30% 92 ± 29 118 ± 75 298 ± 141 2.3 ± 0.5 58 ± 12 63 ± 10
50% 95 ± 34 151 ± 70 350 ± 200 3.2 ± 0.8 57 ± 13 69 ± 18
80% 78 ± 33 181 ± 54 404 ± 194 4.2 ± 1.3 68 ± 15 70 ± 20
Outward torque comf 84 ± 31 147 ± 42 395 ± 190 −2.5 ± 1.0 72 ± 10 54 ± 11
30% 88 ± 23 124 ± 57 345 ± 112 −1.7 ± 1.2 69 ± 14 48 ± 9
50% 74 ± 27 138 ± 61 364 ± 106 −2.2 ± 0.8 76 ± 17 49 ± 9
80% 83 ± 31 167 ± 65 443 ± 154 −3.0 ± 1.1 82 ± 20 53 ± 12
Handle material: Rubber (handle diameter = 57.8 mm)
Method Push force (N) Grip force1 (N) Normal force2 (N) Torque (Nm) FDP (%) FDS (%)
Preferred 136 ± 25 137 ± 65 259 ± 68 1.5 ± 2.3 64 ± 20 56 ± 18
Straight 112 ± 27 115 ± 50 199 ± 69 0.3 ± 0.6 51 ± 11 51 ± 11
Inward torque comf 110 ± 27 160 ± 56 323 ± 157 3.7 ± 2.5 61 ± 15 68 ± 14
30% 94 ± 27 107 ± 22 209 ± 71 2.5 ± 0.7 53 ± 14 59 ± 13
50% 96 ± 35 144 ± 37 267 ± 115 4.1 ± 1.3 60 ± 15 68 ± 17
80% 97 ± 27 220 ± 55 400 ± 177 6.0 ± 2.0 70 ± 17 75 ± 16
Outward torque comf 92 ± 24 180 ± 46 239 ± 73 −3.5 ± 1.6 71 ± 9 48 ± 6
30% 95 ± 22 125 ± 44 176 ± 48 −2.1 ± 0.7 62 ± 13 48 ± 8
50% 91 ± 32 155 ± 59 216 ± 55 −2.9 ± 1.2 69 ± 12 49 ± 7
80% 74 ± 28 229 ± 78 270 ± 58 −4.4 ± 1.6 79 ± 18 53 ± 5
Female (n=6)
Handle material: Aluminum (handle diameter = 51.2 mm)
Method Push force (N) Grip force1 (N) Normal force2 (N) Torque (Nm) FDP (%) FDS (%)
Preferred 62 ± 22 55 ± 21 142 ± 84 0.5 ± 0.4 60 ± 13 70 ± 12
Straight 57 ± 25 51 ± 19 138 ± 85 0.2 ± 0.2 70 ± 13 70 ± 6
Inward torque comf 53 ± 24 67 ± 29 157 ± 94 1.3 ± 0.7 67 ± 14 71 ± 12
30% 49 ± 27 54 ± 25 137 ± 81 0.9 ± 0.6 59 ± 8 70 ± 9
50% 51 ± 27 66 ± 31 151 ± 93 1.3 ± 0.8 59 ± 9 71 ± 13
80% 50 ± 28 81 ± 29 165 ± 107 1.6 ± 1.0 65 ± 10 77 ± 10
Outward torque comf 44 ± 20 51 ± 16 146 ± 74 −1.1 ± 0.6 71 ± 13 66 ± 8
30% 44 ± 27 35 ± 14 107 ± 70 −0.6 ± 0.4 65 ± 17 63 ± 9
50% 46 ± 27 41 ± 19 137 ± 80 −1.0 ± 0.6 74 ± 17 63 ± 12
80% 43 ± 20 60 ± 29 178 ± 117 −1.4 ± 0.9 84 ± 12 67 ± 11
Handle material: Rubber (handle diameter = 57.8 mm)
Method Push force (N) Grip force1 (N) Normal force2 (N) Torque (Nm) FDP (%) FDS (%)
Preferred 65 ± 29 42 ± 18 93 ± 64 0.5 ± 1.1 63 ± 18 64 ± 22
Straight 61 ± 32 38 ± 32 100 ± 121 0.1 ± 0.1 65 ± 13 70 ± 19
Inward torque comf 59 ± 27 53 ± 42 114 ± 120 1.5 ± 1.0 64 ± 16 75 ± 19
30% 61 ± 32 36 ± 16 87 ± 68 1.1 ± 0.7 60 ± 13 72 ± 20
50% 59 ± 28 51 ± 28 112 ± 111 1.6 ± 0.9 63 ± 15 74 ± 18
80% 57 ± 29 64 ± 30 122 ± 120 2.2 ± 1.2 67 ± 17 75 ± 17
Outward torque comf 50 ± 24 67 ± 40 97 ± 82 −1.6 ± 0.9 79 ± 15 68 ± 16
30% 48 ± 26 45 ± 26 62 ± 50 −0.9 ± 0.7 57 ± 11 63 ± 18
50% 47 ± 24 57 ± 39 72 ± 47 −1.4 ± 0.6 66 ± 15 65 ± 18
80% 43 ± 21 68 ± 49 93 ± 79 −1.9 ± 1.1 74 ± 14 67 ± 17
1

Grip force was measured with a split cylinder with the force gauge’s major axis aligned to the forearm (see Figure 1a).

2

Normal force is the total normal contact force between the hand and the cylindrical handle. Normal force was measured with a pressure sensitive pad wrapped around the cylindrical handle (see Figure 1a).

Among all methods, axial push force was greatest for the preferred method, followed by the straight method (Figure 2a). The mean axial push force for the preferred method was 10% greater than that for the straight method (p<0.01). The FDS and FDP EMGs were not significantly different between the two methods. Greater inward torque was observed for the preferred method (1.1 Nm on average; 17% of maximum voluntary inward torque) than for the straight method (0.3 Nm on average; 5% of maximum voluntary inward torque) (p<0.01). The ‘efficiency’ in normal force generation which was accessed by examining the normal force for a given FDP EMG (DeVries, 1968) was greater for the preferred method than for the straight method (p<0.05; Figure 2b). For the preferred and the straight methods combined, high normal force and grip force were associated with high inward torque (p<0.01) and high axial push force (p<0.01).

Figure 2.

Figure 2.

Left, a: Maximum axial push force for four push methods and two handle materials (Mean ± SE). The preferred method was associated with an inward torque that was 17% of the maximum value. Right, b: The efficiency of normal force generation as the ratio of normal force to FDP EMG for the four push methods (Mean ± SE). (Outward: push with a deliberate outward torque, Straight: the straight method with no torque as possible, Preferred: the preferred method, Inward: push with a deliberate inward torque. Pushes with 30%, 50%, 80%, and comfortable inward/outward torques are pooled. Data are pooled from 6 males and 6 females.)

The magnitude of inward torque for the preferred method was not significantly different between the beginning and the end of the experimental trials (p>0.05). Some inward torque was observed for 85% of all straight push and preferred push trials. Even when subjects were instructed to exert axial push forces in the absence of torque (the straight method), subjects produced inward torque which was greater than 0 Nm (p<0.01).

Axial push force decreased with deliberate inward or outward torque, compared to the straight method (Table 2; Figure 2a). Axial push forces for the straight method were not different from those with a comfortable inward torque (p>0.05); however, pushing while also applying 30%, 50%, or 80% inward torques resulted in 15% less axial push force than that for the straight method (p<0.05). For pushes with 30%, 50%, and 80% inward torque, axial push force did not vary significantly with the magnitude of inward torque (p>0.05 for both handle materials). Among the four methods, axial push force was least with deliberate outward torque (p<0.01; Figure 2a). For pushes with 30%, 50%, 80%, and comfortable outward torque, axial push force decreased with increasing outward torque (p<0.01 for both handle materials).

When the subjects were instructed to specifically produce inward or outward torques while pushing, FDS and FDP EMGs, normal forces, and grip forces were greater compared to those for the straight method (p<0.05; Table 2). Compared to the straight method, the efficiency in normal force generation was worse for the pushes with deliberate outward torques, and better for the pushes with deliberate inward torques (p<0.05; Figure 2b). Despite the increases in normal forces, grip forces, and FDS and FDP EMGs, axial push force did not increase for the pushes with deliberate torques compared to the straight method.

From a modeling stand point, axial push force was predicted by multiplying the normal force and static friction coefficient as described in Figure 1a, for the preferred method. The average static friction coefficient between the hand and the handle has been estimated to be 0.33 for aluminum (Buchholz et al., 1988) and 0.77 for rubber (Bobjer, 2004). Predicted axial push forces were not significantly different from the measured axial push forces (p>0.05) for the aluminum handle (see Figure 3). For the rubber handle, predicted axial push forces were, on average, 35% greater than measured axial push forces (p<0.01).

Figure 3.

Figure 3.

Comparison between measured and predicted axial push force for the rubber handle (empty circles, segmented line) and aluminum handle (cross, solid line).

DISCUSSION

Hypothesis 1: Effect of Handle Friction on Axial Push Force

The data support the hypothesis that axial push force is related to handle friction: Axial push force was 12% greater for the high friction rubber handle than for the low friction aluminum handle (p<0.01), even though grip force and FDP and FDS EMG were not different between the two handle materials (p>0.05, for the preferred and the straight methods). This suggests that the weakest link in the chain is the friction between the hand and handle.

Maximum whole-body push force can be limited by slippage between the hand and a work object. Compared to previous studies that measured push force in the absence of friction constraints, the present study with a hand-handle friction resulted in less push force. In this study in which friction was limiting, the highest axial push force was 179 N for a male, which is about 38% to 51% of male maximum push forces in which friction was not limiting, reported by Chaffin et al. (1983), Daams (1993), and Peebles and Norris (2003). Similarly, the highest axial push force measured for a female in this study, 152 N, was about 36% to 70% of reported female maximum push forces with no friction constraints by Chaffin et al. (1983), Daams (1993), and Peebles and Norris (2003). None of the axial push forces measured in this study exceeded the maximum ‘acceptable’ push forces recommended by Davis and Stubbs (1977) and Snook and Ciriello (1991) in which friction was not limiting. The highest axial push force in this study under high friction conditions was about 41% to 61% less than the maximum acceptable push force by Davis and Stubbs (1977) and Snook and Ciriello (1991) (for both genders). Note that the push posture in the present study was similar to these previous studies (Chaffin et al., 1983; Daams, 1993) wherein a freely adopted posture was used, usually with one foot placed in front of the other foot and the torso leaned in the direction of push, with the handle at about the elbow height. No slipping between the shoes and the floor was observed throughout the experiment. This suggests that handle friction limits axial push force, if wrist strength is not limiting. It also indicates that the current standards for pushing overestimate the abilities of the population for cylindrical axial handles.

Since the static friction coefficient was approximately twice greater for rubber (0.77) than for aluminum (0.33), twice greater axial push force was expected for the rubber handle than for the aluminum handle from the axial push model in Figure 1a. The difference in measured axial push force between the rubber and aluminum handles turned out to be only 12%. Two reasons may exist for the small difference. First, it may be due to different handle diameters used for the two handles. The diameters for the rubber and aluminum handles were 57.8 and 51.2 mm, respectively, in this study. Previous studies have shown that maximum grip force decreases with increasing handle diameter for handle diameters greater than 38 mm (Ayoub and Lo Presti, 1971; Edgren et al., 2004; Grant et al., 1992). For example, in the study by Edgren et al. (2004), as a handle diameter increased 25% from 50.8 to 63.5 mm, average maximum grip force decreased 14% from 228 to 197 N. Similarly, in the present study, as the handle diameter increased 13% from 51.2 (aluminum handle) to 57.8 mm (rubber handle), maximum grip force decreased 5% and maximum normal force decreased 20%. Thus, decreased grip force and normal force due to a greater handle diameter, could have reduced maximum axial push force for the rubber handle.

Second, maximum axial push force may also be limited by wrist strength. Pushing in the axial direction of the handle results in reaction force from the handle to the hand in the opposite direction (see Figure 1b). This reaction force generates a moment about the wrist joint in the ulnar direction, which then requires radial deviators’ activity to stabilize the wrist. According to Delp et al. (1996), average males can produce approximately 147 N with their radial deviators. This is only 8% greater than the average axial push force observed for males, for the high friction rubber handle in this study (Table 2). Thus, axial push force exertions may have been limited not only by handle friction, but also by wrist abduction strength. This is probably why measured axial push force for the rubber handle was less than predicted (Figure 3). When the wrist becomes deviated in the ulnar direction more when pushing, however, the passive force of the wrist will increase and the wrist may not be a limiting factor for axial push.

Grieshaber (2007) measured axial push force for a fixed handle (with no universal joints and a handle diameter of 60 mm) and reported about a two-fold higher axial push force than this study. This may be because subjects could apply downward force on a fixed handle. First, with a downward force exertion, normal force on the handle comes not only from the gripping activity, but also from the downward force exertion. The increased normal force can result in increased axial push force. Secondly, a downward force can result in a decreased moment about the wrist, as shown in Equation 1. A downward force results in a reaction force upward, which generates a moment about the wrist in the radial direction (see Figure 1c). This is an opposite moment from that generated by the reaction force from pushing (ulnar direction). Thus, the two moments from the two reaction forces will counterbalance, reducing a resultant moment about the wrist joint and relieving loads on the wrist deviators. For example, if moment arms for the two reaction forces are equal, a downward force equivalent to 20% of axial push force can reduce the moment about the wrist by 20%.

Moment about the wrist = Reaction force × Moment arm= Reaction force for axial push × moment arm  Reaction force for downward force × moment arm (1)

Hypothesis 2: Effect of Torque on Axial Push Force

The data for the straight and preferred methods support the hypothesis that inward torque would result in increased axial push force. It was observed that subjects preferred to use about 17% of maximum inward torque while axial pushing (1.1 Nm on average, Table 2). The amount of inward torque subjects preferred to use while pushing with their preferred method was significantly greater than 0 Nm (p<0.01). Even though FDP and FDS EMGs did not vary with inward torque level, grip force and normal force were positively correlated with the inward torque and axial push force (p<0.01). Therefore, it appears that during pushing with the preferred method, inward torques helped subjects increase grip forces and normal forces, and, thus increase axial push force, without more effort from the finger flexor muscles. It agrees to our previous finding that friction force towards the proximal end of the fingertip causes flexion of the distal phalanges, and increases the normal force on the fingertip (Seo et al., In Press; 2008).

Axial push force was the least with a deliberate outward torque (only 70% of axial push force for the preferred method; see Figure 2a); and it decreased 12% as the outward torque level increased from 30% to 80% (Table 2), which also supports the hypothesis. Contrary to the prediction, however, axial push force with a deliberate inward torque was 12% less than that for the straight method (p<0.01, inward torque level pooled), even though the normal force and the ratio of normal force to FDP EMG increased 25% and 27% with deliberate inward torque, respectively (Table 2; Figure 2b). It may be because the instruction imposed an extra torque task in addition to pushing. Also, subjects may have perceived the instructed push method with the deliberate inward or outward torque requirements as unnatural, which, in turn, may have lowered their push force. This is similar to what Daams (1994) reported: that standardized postures were perceived by many subjects as unnatural and uncomfortable, and that the forces measured in such a posture were often less than those exerted in a free, unrestricted posture. Therefore, it appears that, even though voluntary inward torque results in increased axial push force, instructed inward torque may not necessarily improve axial push force.

LIMITATIONS AND FUTURE WORK

The experimental design in this study did not separate the effect of the handle friction from the effect of the handle diameter as they both changed at the same time. Future studies should eliminate this confounder. In addition, the handle diameter used in this study was greater than the “optimal” handle diameter that results in the highest grip force – 38 mm according to Ayoub and Lo Presti (1971) and Edgren et al. (2004). Thus, use of handles whose diameters are close to 38 mm can result in higher axial push forces than reported in this study. A large handle diameter used in this study was due to difficulty to wrap the pressure pad around a small diameter cylinder. Future studies may evaluate the effect of handle diameter.

Maximum grip forces measured in this study were 17% and 43% lower than those reported by Edgren et al. (2004) for males and females, respectively. This may be because axial pushing on a horizontal handle at elbow height required wrist ulnar deviation, and ulnar deviation has been shown to reduce grip strength approximately 30% (Lamoreaux and Hoffer, 1995; O’Driscoll et al., 1992). Also, the average grip strength of female subjects who participated in this study was only in the 23rd percentile, based on normative data by Mathiowetz et al. (1985). Thus, the average female axial push force may be higher than reported herein.

Inward or outward torque levels required in this experiment (30%, 50%, and 80% of maximum torque) may have been higher than the torque that subjects can comfortably generate and match while pushing maximally at the same time. In fact, the torque level subjects preferred to use (for the preferred method) was only 17% of their maximum inward torque. Thus, instructing subjects to generate high inward or outward torques on top of maximum push force exertion may have resulted in decreased push force.

Subjects freely chose a posture in this study under one constraint that the handle was located at the elbow height. In reality, however, the handle may be located above the head or at the ankle height, which may lead subjects to adopt to a different posture that makes it difficult to apply inward torque. It will be useful to examine the effects of different handle locations and constraints on body posture on torque, normal force, and thus axial push force.

The data reported here were collected from subjects with little labor work experience. Thus the data may be useful for consideration in product design for the general population. In work places such as assembly plants where workers have more experience, greater torques may be observed than reported here. Also, when a given task requires a small axial push force, then people may not necessarily apply inward torque. Future studies may investigate the effect of individual experience and required level of efforts on push methods.

CONCLUSIONS

  1. Axial push forces can be limited by a low handle friction: Axial push forces increased 12% for the high friction rubber handle, compared to that for the low friction aluminum handle. Comparison with previous studies suggests that the limiting factors for axial push force were the friction between the hand and handle, and wrist strength. Literatures that report push force in the absence of friction constraints seem to significantly overestimate people’s axial push capabilities. Use of a high friction handle may improve the axial push force that can be produced on a handle by a worker of a given strength.

  2. Inward torque should be assumed for highest axial push forces, and will be obtained when subjects are free to select their own push method. During pushing in a preferred way, subjects chose to use inward torque of 1.1 Nm (17% of maximum inward torque). The self-chosen inward torque appeared to help increase grip force and normal force on the handle, and thus increase axial push force by 10%, without increasing FDP and FDS muscle activities. Work objects or consumer products should be designed so that workers or users can use inward torque while axial pushing.

  3. Tasks that require deliberate twisting in either direction, but particularly in an outward direction while pushing can result in decreased axial push force.

ACKNOWLEDGEMENTS

This project was funded in part by joint funds from the UAW-GM National Joint Committee on Health and Safety and by NIOSH pilot grant. The results presented herein represent the conclusions and opinions of the authors. Its publication does not necessarily imply endorsement by the International Union, UAW, General Motors Corporation, or NIOSH.

BIOGRAPHIES

Na Jin Seo

Department of Industrial and Operations Engineering, University of Michigan

Ph.D. Industrial and Operations Engineering, 2007, University of Michigan

Thomas J. Armstrong

Department of Industrial and Operations Engineering, University of Michigan

Ph.D. Ergonomics, 1976, University of Michigan

Don B. Chaffin

Center for Ergonomics, University of Michigan

Ph.D. Industrial Engineering, Biomedical Engineering, and Occupational Health, 1967, University of Michigan

James A. Ashton-Miller

Department of Mechanical Engineering, University of Michigan

Ph.D. Biomechanics, 1982, University of Oslo, Norway

Contributor Information

Na Jin Seo, 1205 Beal Ave., Industrial and Operations Engineering, University of Michigan, Ann Arbor, MI, 48109 USA.

Thomas J. Armstrong, Industrial and Operations Engineering, University of Michigan, Ann Arbor, MI, USA

Don B. Chaffin, Center for Ergonomics, University of Michigan, Ann Arbor, MI, USA

James A. Ashton-Miller, Mechanical Engineering, University of Michigan, Ann Arbor, MI, USA

REFERENCES

  1. Armstrong TJ, Buckle P, Fine LJ, Hagberg M, Jonsson B, Kilbom A, Kuorinka IA, Silverstein BA, Sjogaard G, Viikari-Juntura ER, 1993. A conceptual model for work-related neck and upper-limb musculoskeletal disorders. Scandinavian Journal of Work Environment and Health 19 (2) 73–84. [DOI] [PubMed] [Google Scholar]
  2. Ayoub MM, Lo Presti P, 1971. The Determination of an Optimum Size Cylindrical Handle by Use of Electromyography. Ergonomics 14 (4) 509–518. [DOI] [PubMed] [Google Scholar]
  3. Basmajian JV, 1989. Biofeedback: Principles and Practice for Clinicians (3rd Ed). Baltimore: Williams & Wilkins. [Google Scholar]
  4. Bobjer O, 2004. Friction and discomfort in the design and use of hand tools A doctorial thesis. The Loughborough University of Technology. [Google Scholar]
  5. Buchholz B, Frederick LJ,. Armstrong TJ, 1988. An investigation of human palmar skin friction and the effects of materials, pinch force and moisture. Ergonomics 31 (3) March, 317–325. [DOI] [PubMed] [Google Scholar]
  6. Bystrom S, Fransson-Hall C, 1994. Acceptability of intermittent handgrip contractions based on physiological response. Human Factors 36 (1) 158–71. [DOI] [PubMed] [Google Scholar]
  7. Byström S, Kilbom A, 1990. Physiological response in the forearm during and after intermittent handgrip, European Journal of Applied Physiology 60, 457–466. [DOI] [PubMed] [Google Scholar]
  8. Chaffin DB, Andres RO, Garg A, 1983. Volitional postures during maximal push/pull exertions in the sagittal plane. Human Factors, 25, 541–550 [DOI] [PubMed] [Google Scholar]
  9. Daams BJ, 1993. Static force exertion in postures with different degrees of freedom. Ergonomics, 36, 397–406. [DOI] [PubMed] [Google Scholar]
  10. Daams BD, 1994. Human Force Exertion in User-Product Interaction – Backgrounds for Design Physical Ergonomics Series, Vol. 2 Delft University Press, Delft, The Netherlands. [Google Scholar]
  11. Davis PR, Stubbs DA, 1977. Safe levels of manual forces for young males (1). Applied Ergonomics 8 (3) 141–150. [DOI] [PubMed] [Google Scholar]
  12. DeVries HA, 1968. “Efficiency of electrical activity” as a physiological measure of the functional state of muscle tissue. Am J Phys Med 47 (1) 10–22. [PubMed] [Google Scholar]
  13. Drury CG, 1980. Handles for manual materials handling. Applied Ergonomics 11 (1) 35–42. [DOI] [PubMed] [Google Scholar]
  14. Ebersole M and Armstrong T, 2004. An analysis of task-based worker self-assessments of force Proceedings of the Human Factors and Ergonomics Society 48th Annual Meeting, New Orleans, LA, September 20–24. [Google Scholar]
  15. Edgren CS, Radwin RG, Irwin CB, 2004. Grip force vectors for varying handle diameters and hand sizes. Human Factors 46 (2) 244–251. [DOI] [PubMed] [Google Scholar]
  16. Garland SJ, Miles TS, 1997. Control of motor units in human flexor digitorum profundus under different proprioceptive conditions. Journal of Physiology 5023, 693–701. [DOI] [PMC free article] [PubMed] [Google Scholar]
  17. Garrett JW, 1971. The Adult Human Hand: Some Anthropometric and Biomechanical Considerations. Human Factors 13 (2) 117–131. [DOI] [PubMed] [Google Scholar]
  18. Grant KA, Habes DJ, 1993. Effectiveness of a handle flange for reducing manual effort during hand tool use. International Journal of Industrial Ergonomics 12, 199–207. [Google Scholar]
  19. Grant KA, Habes DJ, Steward LL, 1992. An analysis of handle designs for reducing manual effort: The influence of grip diameter. International Journal of Industrial Ergonomics 10, 199–206. [Google Scholar]
  20. Grieshaber DC, 2007. Use of a Biomechanical Model of the Hand to Evaluate Physical Task Requirements. Dissertation. Department of Industrial and Operations Engineering, University of Michigan, Ann Arbor. [Google Scholar]
  21. Lamoreaux L, Hoffer MM 1995. The Effect of Wrist Deviation on Grip and Pinch Strength. Clinical Orthopaedics and Related Research 314, 152–155. [PubMed] [Google Scholar]
  22. Malker B, 1991. Occupational disease and occupational accidents 1989 Official Statistics of Sweden National Board of Occupational Safety and Health. Stockholm: 1991. [Google Scholar]
  23. Mathiowetz V, Kashman N, Volland G, Weber K, Dowe M, Rogers S, 1985. Grip and Pinch Strength: Normative Data for Adults. Arch Phys Med Rehabil 66: 69–72. [PubMed] [Google Scholar]
  24. Nagashima K, Konz S, 1986. Jar lids: effect of diameter, gripping materials and knurling In Proceedings of the human factors society 30th annual meeting, 672–674. [Google Scholar]
  25. NRC, 1999. Work-related musculoskeletal disorders: a review of the evidence. Washington, DC, National Academy Press. [Google Scholar]
  26. NRC and IOM, 2001. Musculoskeletal Disorders and the Workplace: Low Back and Upper Extremities. Washington, DC, National Academy Press. [PubMed] [Google Scholar]
  27. O’Driscoll SW, Horii E, Ness R, Cahalan TD, Richards RR, An K-N, 1992. The relationship between wrist position, grasp size, and grip strength. The Journal of Hand Surgery 17A (1) 169–177. [DOI] [PubMed] [Google Scholar]
  28. Peebles L, Norris B, 2003. Filling ‘gaps’ in strength data for design. Applied Ergonomics 34, 73–88. [DOI] [PubMed] [Google Scholar]
  29. Pheasant S, O’Neill D, 1975. Performance in gripping and turning – a study in hand/handle effectiveness. Applied Ergonomics 6 (4) 205–208. [DOI] [PubMed] [Google Scholar]
  30. Rohmert W, 1973. Problems in determining rest allowances. Applied Ergonomics 4 (2) 91–95. [DOI] [PubMed] [Google Scholar]
  31. Seo NJ, Armstrong TJ, Ashton-Miller JA, Chaffin DB. The effect of torque direction and cylindrical handle diameter on the coupling between the hand and a cylindrical handle. Journal of Biomechanics, In Press. [DOI] [PubMed] [Google Scholar]
  32. Seo NJ, Armstrong TJ, Chaffin DB, Ashton-Miller JA. Inward torque and high friction handle can reduce required muscle efforts for torque generation. Human Factors 2008. [DOI] [PubMed] [Google Scholar]
  33. Snook S, Ciriello VM, 1991. The design of manual handling tasks: revised tables of maximum acceptable weights and forces. Ergonomics 34 (9) 1197–1213. [DOI] [PubMed] [Google Scholar]

RESOURCES