Abstract
BACKGROUND
Although electrical burns are less prevalent than other types, they put socioeconomic burden on communities, yielding higher mortalities. Therefore, the frequency and causes of electrical burns in the largest burn center in northern Iran were studied.
METHODS
All patients with electrical burn injuries admitted to Velayat Hospital, Rasht, Iran participated in this descriptive cross-sectional study. The data collection tool was a checklist including demographic data, damage mechanism, voltage classification (high or low), injured organ, ICU need, length of stay (LOC), electrical burn severity (degree and area of burns based on TBSA), surgical interventions, and return to work. All data were gathered through HIS system and analyzed.
RESULTS
Most electrical burns occurred in men (99.4%) and most of whom had electricity-related jobs (26%). The majority of victims had third-degree burns (63%), and electrical current-induced burns in entry points occurred in the upper and lower extremities, head and other organs ranked the first to fourth, respectively. Most burns happened due to abrupt contact with electrical current (83.33%) in routine home activities (52.78%). The mean LOC was 8.73 days, suggesting that LOC increased significantly, if the electrical current entered the body through lower extremities, while it decreased significantly, if the electrical current exited through lower extremities.
CONCLUSION
The majority of electrical burn victims were men. Most burns occurred in urban communities in summer. Most people were affected by high voltage electricity.
Key Words: Epidemiology, Electrical burn, Iran
INTRODUCTION
Electrical injuries are among the most important health problems worldwide. Despite the numerous efforts to reduce the number of electrical damages, their incidence has an increasing trend.1,2 Electrical burns account for about 3-6% of hospitalization in burn wards.3 In the United States, electrical burns are responsible for 4-6.5% of hospitalization in burn wards, which annually cause 1,000 deaths.4 The incidence of electricity-induced injuries is higher in rural areas and outskirts in developed countries compared to developing nations.5
Electrical damages in our country is much more frequent than developed countries and has many negative socioeconomic impacts.6 Although electrical burns are less common than other types of burn, they are among harmful damages and cause a higher mortality rate.7 They are the third leading cause of burns, following scald and flame-induced burns that put heavier socioeconomic burdens on communities in spite of advanced therapeutic modalities and decreasing mortality rates than other types of burns.8 The victims of electrical burns are often small children, adolescents and young people in working age.2,9,10
Electrical burns often cause damage to both parts of skin (superficial, deep) and also deeper tissues, and can lead to large areas of necrosis.11 The mechanism of electrical burn damage is complex and unknown, and depends on several factors such as damaged area, contact time, and electrical current intensity.2 These burns are divided into four groups according to the damage mechanism including (i) direct contact with an electric heater, (ii) indirect contact with a flame, (iii) indirect contact with electricity, and (iv) indirect contact with an electric-thermal equipment.12
These damage are also divided into three categories in terms of the mechanism including (1) electrical damage; (2) damage to the flexor surfaces of the body, such as the armpit; and (3) heat damage caused by a flame, the damage caused by the combustion of clothing. The severity of tissue damage can be classified according to the electrical intensity (low and high voltage), the type of current (direct or indirect), the affected part of the body, the contact time, and simultaneous secondary damages.12 They can also be classified into two main groups, burns with a current above 1000 volts and below 1000 volts.3
Low voltage-induced burns result in inability and destruction in the affected site tissue, while high voltage-induced burns cause systemic damages.13 Electricity-caused damages have immediate consequences in short- term and require extensive medical intervention, and their complications are much deeper and more difficult to detect in the long run.14 Since the exact diagnosis of electrical burn severity is difficult, and many people underestimate it,15 this study aimed to investigate electrical burns and associated factors in burn patients at Velayat Burn Center of Guilan University of Medical Sciences, Rasht, Guilan, Iran.
MATERIALS AND METHODS
This descriptive cross-sectional study enrolled 108 patients, suffering from electrical burn injuries admitted to Velayat Teaching Hospital in Rasht (Burn Center of Guilan Province, Northern Iran) in a six year-period (2011-2016). The data collection tool was a checklist containing the demographic data (age, sex, level of education, location of injury), damage mechanism, voltage classification (high or low), intensive care unit (ICU) need, length of stay, electrical burn severity (degree and area of burns based on Total Body Surface Area: TBSA), surgical interventions (fasciotomy, escharotomy, amputation), and return to work. Patients with partial information, incomplete treatment period, and discharged against medical advice were excluded from the study.
Once the patient was admitted to the hospital, the degree of burn and affected surface area of the body (TBSA) were determined, and then tests of cardiac rhythm and kidney function (intake/output, myoglobinuria, blood urea nitrogen (BUN) and serum creatinine levels) and if needed, resuscitation were conducted. In case of thermal damage, Parkland’s formula was used. Adequate resuscitation was evaluated by monitoring the amount of urine output. In the first line, oral or injectable non-steroidal anti-inflammatory drugs were used routinely to manage the pain of the patients, and in the second line, opiate drugs were taken.
Daily dressing, debridement, and skin grafting were done as needed. Patients were carefully evaluated for compartment symptoms and, if necessary, fasciotomy or delayed guillotine amputation was performed and, if necessary, the amputation site was corrected. Amputations were performed only in sterile conditions, and antibiotic therapy was undertaken for those who had positive culture samples. All data were collected through HIS system and analyzed using SPSS software (version 21, Chicago, IL, USA) and descriptive statistics tests.
RESULTS
The whole 108 patients including 102 male patients (94.4%) and 6 female patients (5.6%), aged between 1 and 72 years with a mean age of 31.56 years, participated in the study. The most common frequency of burns was found in patients with diploma and higher educational level, followed by illiterate patients and those with elementary education. Most people with burns had electricity-related jobs (26%). The burns occurred mostly in urban communities in summer months. While the third-degree burns took place more frequently (63%), the surface area of burn was commonly low (0-19%, n=97).
Burns induced by electrical current in entry points were mainly observed in upper and lower extremities, head and other organs ranked the first to fourth, respectively, while electrical burns in exit points occurred inversely except for the head. Most victims were damaged with high voltage electricity (n=68, 62.96%). The burns occurred predominantly due to abrupt contact with electrical current (n=90, 83.33%) in daily routine activities at home (52.78%, Table 1).
Table 1.
Variable | Frequency | Percent | |
---|---|---|---|
Education | Illiterate | 24 | 22.22 |
Elementary | 4 | 3.70 | |
Diploma and higher | 80 | 74.07 | |
Season | Spring | 34 | 31.48 |
Summer | 39 | 36.11 | |
Autumn | 25 | 23.15 | |
Winter | 10 | 9.26 | |
Accident location | Urban areas | 80 | 74.07 |
Rural areas | 28 | 25.93 | |
Burn surface area | 0-19 | 97 | 89.8 |
20-39 | 7 | 6.5 | |
40-59 | 3 | 2.8 | |
60-100 | 1 | 0.9 | |
Burn degree | First | 2 | 1.9 |
Second | 28 | 25.9 | |
Third | 68 | 63 | |
Fourth | 10 | 9.3 | |
Electrical current Entry point | Upper extremities | 96 | 88.89 |
Lower extremities | 9 | 8.33 | |
Head | 2 | 1.85 | |
Others | 1 | 0.93 | |
Electrical current exit point | Upper extremities | 21 | 19.44 |
Lower extremities | 29 | 26.85 | |
Head | 2 | 1.85 | |
Others | 56 | 51.85 | |
Accident cause | Abrupt contact with electricity current | 90 | 83.33 |
Accidents at work | 9 | 8.33 | |
Lightning | 9 | 8.33 | |
Accident place | Home | 57 | 52.78 |
Workplace | 19 | 17.59 | |
Shop | 17 | 15.74 | |
Others | 15 | 13.89 |
The length of stay varied from 1 to 45 days, with the mean of 8.73 days. Poisson regression analysis showed that the length of stay in men was significantly less than that in women. Age had an inverse relationship with the length of stay, so that the probability of hospitalization decreased significantly (0.007) with the one year increase in age. Also, people with electrical burns above 50% and 75% showed a 2.5 and 5.3 time increase, respectively, in the probability of length of stay, which was statistically significant.
There was no significant relationship between the second- and third-degree burns with length of stay, while length of stay in the patients with the fourth-degree burns was 6.1 times higher than that in others. If the electrical current entered the body through lower extremities, the length of stay increased significantly, while the length of stay declined significantly, if the electrical current exited the body through lower extremities.
DISCUSSION
According to the World Health Organization (WHO), 195,000 people die annually because of burns. Most deaths occur in low- and middle-income countries and half of them in the Southeast Asia.16 Among several types of burns, electrical burn is one of the most disturbing kinds of trauma.17 Although patients with electrical burn injuries account for less than 5% of all admissions in the burn centers globally, they bring out significant morbidities and mortalities.8,18 Similar to many previous researches, most patients employed in the current study are young men in working age.
This is likely to be the result of recruiting men in occupations that are related to electrical currents and heavy equipment and machinery. Furthermore, burn accidents may happen due to inadequate equipment and training.19-21 Human errors can also be considered to be among the negative influencing factors, but appropriate training can eliminate their effects, as demonstrated in various studies.22,23 Our study showed that the electrical current entered the body more commonly through upper and lower extremities, and head ranked the first to third, respectively.
Li and colleagues found that head, face, and neck were the most frequent location of electrical burns.24 In the present study, most patients were injured with high-voltage electrical current (n=68, 62.96%), while Li et al. showed that most of the patients were affected by low voltage.24 The present study found that the most common burns happened through a sudden contact with the electrical current. It may be because of the lower level of safety standards in that environment in developing countries than developed nations.
Other studies have confirmed that electrical accidents take place more commonly in the indoor settings in the countries such as Brazil or Nigeria compared to European countries. These regional differences suggest that prevention safety standards have not been established in all parts of the world, and much work has still to be done.9,25 In electricity-damaged areas (electricity entry and exit points), third- and fourth-degree burns with full skin necrosis are seen, and sometimes with tissue necrosis under the skin such as fascia, nerves, muscles, tendons, vessels and bones.
Normally, the area involved in these parts is very small, and does not include more than 1% of the body surface. However, deep muscles in most cases and even superficial muscles in some extent are burned due to severe heat. The heat generated directly is related to the resistance of that part of the body and the voltage. In high voltage injuries, much more serious injuries and burns happen in muscles.26,27 According to results of the study, high voltage electrical injuries were among the most common reasons for admitting patients.
Considering that most of our study patients had burn under 19% based on TBSA, and most cases had the third-degree burns, higher length of stay could be justified. In Brazil, a similar study showed a relationship between high-voltage burns with severity of injuries, clinical complications, and amputations. Moreover, the length of stay was higher in subjects with amputation and compartment syndrome.8,28 In our study, less than 1/4 of patients needed fasciotomy and admission to the intensive care unit. These results are consistent with the findings of other studies.29,30
This could be attributed to the timely referral of patients at the very early minutes after burn to the hospital and their proper management. In our study, almost all patients were able to return to their job after the recovery process. This can be attributed to monitoring and early advanced resuscitation, more improved management of wound and surgery, and early grafting. Contrary to our findings, Noble et al. stated that patients had remarkable problems when returning to their work. Only 23% of them were able to return to their job and perform the same tasks, while 32% of them could not return to work at all. The rest of the patients were forced to work in the same job by modifying their duties or in another occupation.31
The current study also found that most electrical accidents occurred in urban areas. This contradicts the findings of the study by Rao et al., who introduced rural environments more insecure than urban settings because of not observing safety precautions.32 The more frequent electrical accidents in summer months compared to other seasons may be due to sweating increases in summer, which in turn reduces skin resistance and thus raises the flow of electrical current through the body.33 Indeed, electrical damages happen commonly in urban regions and hot weather during the theft of expensive copper cables,2,34 or during illegal cabling in order to not paying tariffs assigned to use cooling devices such as air conditioners in developing countries with many socioeconomic problems.
Poisson regression analysis showed that the length of stay in men was significantly less than that in women due to that men have lower degree of burn because of their thicker skin leading to faster treatment. The age had an inverse relationship with the length of stay, so that the probability of hospital attendance decreased significantly (0.007) with one year increase in age. Also, people with electrical burns above 50% and 75% raised the probability of their length of stay as 2.5 and 5.3 times, respectively, which was statistically significant.
A study conducted by Lunawat et al. showed that the length of stay was between 4 and 83 days with mean length of 23.53 days. The patients with high TBSA had longer length of stay.35 Our study found that the length of stay in the patients with the fourth-degree burns was 6.1 times higher than that in others. Ghavami et al. in their study showed that the length of stay was higher at high voltages.2 Our study found that the majority of electrical burn victims were men. Most burns occurred in urban communities in summer months.
The people suffering from electrical burn were predominantly damaged by high voltage electricity, so burn prevention should be the top priority, and government programs should focus on the safety and proper management of electrical appliances. Occupational safety acts must be revised, and employers must respect these regulations. Workers exposed to electrical equipment must be fully trained and certified.
CONFLICT OF INTEREST
The authors declare no conflict of interest.
References
- 1.Vahdati SS, Moradi N, Ghadim JH. Evaluation of electrical injury in East Azarbaijan Province, Iran. J Analyt Res Clin Med. 2013;1:22–4. [Google Scholar]
- 2.Ghavami Y, Mobayen MR, Vaghardoost R. Electrical burn injury: a five-year survey of 682 patients. Trauma Mon. 2014;19:e18748. doi: 10.5812/traumamon.18748. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Kym D, Seo DK, Hur GY, Lee JW. Epidemiology of electrical injury: Differences between low- and high-voltage electrical injuries during a 7-year study period in South Korea. Scand J Surg. 2015;104:108–14. doi: 10.1177/1457496914534209. [DOI] [PubMed] [Google Scholar]
- 4.Mohammadi AA, Amini M, Mehrabani D, Kiani Z, Seddigh A. A survey on 30 months electrical burns in Shiraz University of Medical Sciences Burn Hospital. Burns. 2008;34:111–3. doi: 10.1016/j.burns.2006.12.007. [DOI] [PubMed] [Google Scholar]
- 5.Teodoreanu R, Popescu SA, Lascar I. Electrical injuries Biological values measurements as a prediction factor of local evolution in electrocutions lesions. J Med Life. 2014;7:226–36. [PMC free article] [PubMed] [Google Scholar]
- 6.Wesner ML, Hickie J. Long-term sequelae of electrical injury. Can Fam Physician. 2013;59:935–9. [PMC free article] [PubMed] [Google Scholar]
- 7.Price TG, Cooper MA. Electrical and lightning injuries. In: Marx J, editor. Rosen’s Emergency Medicine-Concepts and Clinical Practice. Mosby; 2006. pp. 67–78. [Google Scholar]
- 8.Kurt A, Yildirim K, Yagmur C, Kelahmetoglu O, Aslan O, Gumus M, Guneren E. Electrical burns: Highlights from a 5-year retrospective analysis. Ulus Travma Acil Cerrahi Derg. 2016;22:278–82. doi: 10.5505/tjtes.2015.55491. [DOI] [PubMed] [Google Scholar]
- 9.Patil SB, Khare NA, Jaiswal S, Jain A, Chitranshi A, Math M. Changing patterns in electrical burn injuries in a developing country: should prevention programs focus on the rural population? J Burn Care Res. 2010;31:931–4. doi: 10.1097/BCR.0b013e3181f93924. [DOI] [PubMed] [Google Scholar]
- 10.Glatstein MM, Ayalon I, Miller E, Scolnik D. Pediatric electrical burn injuries: experience of a large tertiary care hospital and a review of electrical injury. Pediatr Emerg Care. 2013;29:737–40. doi: 10.1097/PEC.0b013e318294dd64. [DOI] [PubMed] [Google Scholar]
- 11.Karimi H, Momeni M, Vasigh M. Long term outcome and follow up of electrical injury. J Acute Dis. 2015;4:107–11. [Google Scholar]
- 12.Rezaei E, Motamedoshariati M, Safari H. A Study of Electrical Injuries in Emam Reza Burn Center of Mashhad. medical journal of mashhad university of medical sciences. 2009;52:107–12. [Google Scholar]
- 13.Lipovy B, Kaloudova Y, Rihova H, Chaloupkova Z, Kempny T, Suchanek I, Brychta P. High voltage electrical injury: an 11-year single center epidemiological study. Ann Burns Fire Disasters. 2014;27:82–6. [PMC free article] [PubMed] [Google Scholar]
- 14.Jain S, Sharma S, Sinha S, Jain S. Electric Burns Injuries of Head and Neck Region: A Retrospective Study. Int J Sci Study. 2014;1:47–9. [Google Scholar]
- 15.Surendranath Borra YK. Electrical burns. National Journal of Medical and Dental Research. 2015;3:166–9. [Google Scholar]
- 16.Organization WH. Media centre: Fact sheets – Burns. Geneva: WHO; 2016. [Google Scholar]
- 17.Manafi A, Kohanteb J, Mehrabani D, Japoni A, Amini M, Naghmachi M, Zaghi AH, Khalili N. Active immunization using exotoxin A confers protection against Pseudomonas aeruginosa infection in a mouse burn model. BMC Microbiol. 2009;9:23. doi: 10.1186/1471-2180-9-23. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Shih JG, Shahrokhi S, Jeschke MG. Review of Adult Electrical Burn Injury Outcomes Worldwide: An Analysis of Low-Voltage vs High-Voltage Electrical Injury. J Burn Care Res. 2017;38:e293–e8. doi: 10.1097/BCR.0000000000000373. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Vierhapper MF, Lumenta DB, Beck H, Keck M, Kamolz LP, Frey M. Electrical injury: a long-term analysis with review of regional differences. Ann Plast Surg. 2011;66:43–6. doi: 10.1097/SAP.0b013e3181f3e60f. [DOI] [PubMed] [Google Scholar]
- 20.Sun CF, Lv XX, Li YJ, Li WZ, Jiang L, Li J, Feng J, Chen SZ, Wu F, Li XY. Epidemiological studies of electrical injuries in Shaanxi province of China: a retrospective report of 383 cases. Burns. 2012;38:568–72. doi: 10.1016/j.burns.2011.10.012. [DOI] [PubMed] [Google Scholar]
- 21.Soto CA, Albornoz CR, Pena V, Arriagada C, Hurtado JP, Villegas J. Prognostic factors for amputation in severe burn patients. Burns. 2013;39:126–9. doi: 10.1016/j.burns.2012.03.001. [DOI] [PubMed] [Google Scholar]
- 22.Haddad SY. Electrical burn - a four-year study. Ann Burns Fire Disasters. 2008;21:78–80. [PMC free article] [PubMed] [Google Scholar]
- 23.Arnoldo BD, Purdue GF, Kowalske K, Helm PA, Burris A, Hunt JL. Electrical injuries: a 20-year review. J Burn Care Rehabil. 2004;25:479–84. doi: 10.1097/01.bcr.0000144536.22284.5c. [DOI] [PubMed] [Google Scholar]
- 24.Li H, Tan J, Zhou J, Yuan Z, Zhang J, Peng Y, Wu J, Luo G. Wound management and outcome of 595 electrical burns in a major burn center. J Surg Res. 2017;214:182–9. doi: 10.1016/j.jss.2017.02.032. [DOI] [PubMed] [Google Scholar]
- 25.Vierhapper MF, Lumenta DB, Beck H, Keck M, Kamolz LP, Frey M. Electrical injury: a long-term analysis with review of regional differences. Ann Plast Surg. 2011;66:43–6. doi: 10.1097/SAP.0b013e3181f3e60f. [DOI] [PubMed] [Google Scholar]
- 26.Sanford A, Gamelli RL. Lightning and thermal injuries. Handb Clin Neurol. 2014;120:981–6. doi: 10.1016/B978-0-7020-4087-0.00065-6. [DOI] [PubMed] [Google Scholar]
- 27.Hinkelbein J, Spelten O, Wetsch WA. [Lightning strikes and lightning injuries in prehospital emergency medicine Relevance, results, and practical implications] Unfallchirurg. 2013;116:74–9. doi: 10.1007/s00113-011-2084-9. [DOI] [PubMed] [Google Scholar]
- 28.Luz DP, Millan LS, Alessi MS, Uguetto WF, Paggiaro A, Gomez DS, Ferreira MC. Electrical burns: a retrospective analysis across a 5-year period. Burns. 2009;35:1015–9. doi: 10.1016/j.burns.2009.01.014. [DOI] [PubMed] [Google Scholar]
- 29.Gille J, Schmidt T, Dragu A, Emich D, Hilbert-Carius P, Kremer T, Raff T, Reichelt B, Siafliakis A, Siemers F, Steen M, Struck MF. Electrical injury - a dual center analysis of patient characteristics, therapeutic specifics and outcome predictors. Scand J Trauma Resusc Emerg Med. 2018;26:43. doi: 10.1186/s13049-018-0513-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Shih JG, Shahrokhi S, Jeschke MG. Review of Adult Electrical Burn Injury Outcomes Worldwide: An Analysis of Low-Voltage vs High-Voltage Electrical Injury. J Burn Care Res. 2017;38:e293–e8. doi: 10.1097/BCR.0000000000000373. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Noble J, Gomez M, Fish JS. Quality of life and return to work following electrical burns. Burns. 2006;32:159–64. doi: 10.1016/j.burns.2005.08.022. [DOI] [PubMed] [Google Scholar]
- 32.Rao J, Bedi M, Patil A, Barala VK. Associated injuries in electrical burns: a 2 year retrospective study in a tertiary care burns unit. International Journal Of Community Medicine And Public Health. 2017;4:2882–5. [Google Scholar]
- 33.Tirasci Y, Goren S, Subasi M, Gurkan F. Electrocution-related mortality: a review of 123 deaths in Diyarbakir, Turkey between 1996 and 2002. Tohoku J Exp Med. 2006;208:141–5. doi: 10.1620/tjem.208.141. [DOI] [PubMed] [Google Scholar]
- 34.Aguilera-Saez J, Binimelis MM, Collado JM, Dos Santos BP, Garcia V, Ruiz-Castilla M, Serracanta J, Barret JP. Electrical burns in times of economic crisis: A new epidemiologic profile. Burns. 2016;42:1861–6. doi: 10.1016/j.burns.2016.06.016. [DOI] [PubMed] [Google Scholar]
- 35.Lunawat A, Datey S, Vishwani A, Khare Y, Ranjan V. Epidemiology and outcome of electric burns at SAIMS, a tertiary care centre of Central India. Journal of Evolution of Medical and Dental Sciences. 2013;2:1761–70. [Google Scholar]