Geant4-based electromagnetic background model for the CRESST dark matter experiment

A H Abdelhameed 1, G Angloher 1, P Bauer 1, A Bento 1,9, E Bertoldo 1, R Breier 2, C Bucci 3, L Canonica 1, A D’Addabbo 3,10, S Di Lorenzo 3,10, A Erb 4,11, F v Feilitzsch 4, N Ferreiro Iachellini 1, S Fichtinger 5, A Fuss 5,6, P Gorla 3, D Hauff 1, M Jes̆kovský 2, J Jochum 7, J Kaizer 2, A Kinast 4, H Kluck 5,6,, H Kraus 8, A Langenkämper 4, M Mancuso 1, V Mokina 5,, E Mondragón 4, M Olmi 3,10, T Ortmann 4, C Pagliarone 3,12, V Palus̆ová 2, L Pattavina 4,10, F Petricca 1, W Potzel 4, P Povinec 2, F Pröbst 1, F Reindl 5,6, J Rothe 1, K Schäffner 1, J Schieck 5,6, V Schipperges 7, D Schmiedmayer 5,6, S Schönert 4, C Schwertner 5,6, M Stahlberg 5,6, L Stodolsky 1, C Strandhagen 7, R Strauss 4, C Türkoğlu 5,6,14,, I Usherov 7, M Willers 4, V Zema 3,10,13, J Zeman 2
PMCID: PMC6820299  PMID: 31708682

Abstract

The CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) dark matter search experiment aims for the detection of dark matter particles via elastic scattering off nuclei in CaWO4 crystals. To understand the CRESST electromagnetic background due to the bulk contamination in the employed materials, a model based on Monte Carlo simulations was developed using the Geant4 simulation toolkit. The results of the simulation are applied to the TUM40 detector module of CRESST-II phase 2. We are able to explain up to (68±16)% of the electromagnetic background in the energy range between 1 and 40keV.

Introduction

Understanding the nature of dark matter (DM) is among the most pressing problems of modern physics. The possible parameter space in terms of mass and interaction cross section of ordinary matter with DM is large, requiring different experimental approaches to exploring it in a comprehensive way. The cryogenic experiment CRESST is one of these experiments, being very well suited for the search for DM particles in the sub-GeV/c2 mass region, down to a few hundred MeV/c2 [1]. A major milestone for the CRESST-II experiment in increasing the sensitivity to sub-GeV/c2 dark matter was the data taking campaign of phase 2: with a detection threshold of (307.3±3.6)eV, the single detector module Lise achieved sensitivity down to 500MeV/c2 [2]. This demonstrates the importance of a sub-keV detection threshold for nuclear recoils. The first time, it was achieved earlier in the same run with the detector module TUM40, for which a threshold of (603±2)eV was obtained [3].

The average background rate previously determined in the crystal used for the TUM40 detector module in the region 1–40 keV of about 3.51kg-1keV-1day-1 [4] is significantly lower compared to crystals of the same material with different origin. The sensitivity for low DM masses was limited by the residual background and detection threshold, hence, further improvements are only possible by identifying and reducing components of this background or lowering the detection threshold.

In this paper we present an analysis of the electromagnetic background sources and their composition [5] for the data taken during CRESST-II phase 2 with the TUM40 detector module [3, 4]. We use the Geant4 toolkit for Monte Carlo simulations [68] as the main tool to calculate the differential energy distribution from the decay of various radioactive isotopes. The normalisation of the energy distribution is obtained from the activity of α-decays in the corresponding natural decay chain in secular equilibrium or from the fit to γ-lines.

In the following, we present the CRESST experiment in Sect. 2. Section 3 focuses on the simulation method and Sect. 4 discusses the determination of the different background contributions. The results are presented in Sect. 5. Section 6 gives a summary and provides a short outlook.

The CRESST experiment

The working principle

The CRESST experiment is located in Hall A of the Laboratori Nazionali del Gran Sasso (LNGS) below the Gran Sasso mountains in central Italy. CRESST-II used cryogenic detectors with scintillating CaWO4 crystals as the target material. Each interaction in the target crystal produces phonons and scintillation photons, which are absorbed by a nearby silicon-on-sapphire (SOS) disk. Around 90% of the total energy deposited in the target crystal are phonons and nearly independent of the interacting particle. On the other hand, the scintillation process is strongly particle-dependent. Its efficiency reaches at most 7% for β/γ-events [9]; for nuclear recoils the scintillation efficiency is reduced by roughly one order of magnitude called quenching. Both signals are read out by separate thermometers which are realised as transition edge sensors (TESs) operated at a temperature of O(15mK) [10]. We refer to the CaWO4 target crystal as “phonon detector” and the SOS disk as “light detector” later on. The ratio between deposited energies in these two channels, defined as the light yield (LY), allows one to determine the type of interaction. The 122keV γ-line coming from a 57Co calibration source is used to normalise the LY of β/γ-band to 1 at 122keV.

Figure 1 shows the expected LY distribution as a function of the deposited energy. As can be seen, a number of bands emerge, separated by their respective LYs. Different bands indicate the different particle interactions inside the target crystal. Starting from high LY values to lower ones, the resulting event categories are: β/γ-events caused by scattering off electrons, α-events and finally events of recoiling O-, Ca- and W-nuclei. The latter three collectively constitute the nuclear recoil bands. A recoil event may be caused by background, e.g. neutrons, or by a potential DM signal. The energy range of interest (ROI) for a DM search in CRESST-II expands from the detection threshold to 40keV. Above this energy, no significant DM signal is expected for CaWO4 [3].

Fig. 1.

Fig. 1

An example LY plot. Different bands show interactions of different event types: β/γ-interactions (blue), α interactions (cyan), oxygen (red), calcium (orange) and tungsten (green) recoils. The hatched area shows the region of interest for a possible signal of DM particles

Most of the radioactive background falls into the β/γ-band which is well separated from the nuclear recoil bands at high energies. However, at lower energies, events from the β/γ-band are leaking into the region of interest. This complicates the DM analysis: since the expected rate of DM particle interactions is low compared to the background rate, a potential signal may be covered by the leakage, or an unknown background can be mistaken for a potential DM signal. Especially at low energies where the ROI for the CRESST experiment is, a detailed understanding of the background is crucial.

The detector setup

Most of the materials close to the detectors are selected for radiopurity to keep backgrounds low. The cold finger design of CRESST helps to avoid any line of sight between the dilution refrigerator and the detectors [11] (see Fig. 2). The design of the CRESST setup features layers of polyethylene (PE), lead and copper shielding against ambient background from natural radioactivity of the laboratory, as well as background caused by the shielding and cryostat itself (see Sect. 2.3 for details).

Fig. 2.

Fig. 2

Technical drawing of the CRESST experimental setup. The cryostat holding the liquid helium and nitrogen can be seen at the top. Below the cryostat, the carousel hosts the detector modules. The shielding consists of PE, lead, copper, an active muon veto and the air-tight radon box used to prevent radon contamination from air

The active muon veto tags when a charged particle penetrates through it. A gas-tight container, the so-called radon box, which is constantly flushed with N2 gas, prevents the accumulation of gaseous radon close to the detectors. The radon box contains a lead shielding, inside this a copper shielding is the direct enclosing of the cold box. The detector modules are placed in the so-called carousel at the core of the coldbox.

A photograph and the schematic view of the TUM40 detector module [12] are shown in Fig. 3a, b, respectively. The target crystal is held by sticks made of the same material—CaWO4 [12] and features a dedicated carrier crystal onto which the TES is evaporated. The phonon and light detectors are enclosed by a reflective scintillating polymeric foil named VM20021, to increase the light collection efficiency and actively reject surface backgrounds. The holder of the detector module is made from radiopure copper. A more detailed description of the TUM40 geometry is given in Sect. 3.1, where the implementation into the simulation code is discussed.

Fig. 3.

Fig. 3

TUM40 detector module as operated in CRESST-II phase 2: a photograph of opened module, the block-shaped target crystal is visible on the right side within the scintillating foil, and b a schematic view

Potential background sources

In this Section, the main background sources and the methods to reduce and identify them will be discussed. For the TUM40 detector module, previous studies [3, 4] found no indication for a significant neutron component to the background. Based on CRESST-II phase 1 we expect <10-3kg-1keV-1day-1 of neutron background [13]. Hence, we focus on the electromagnetic components in this work.

Muons

High energetic atmospheric muons can easily penetrate through meters-thick layers of shielding. For this reason, the CRESST experiment is located in the LNGS underground laboratory, which has an overburden of at least 1400m of rock in each direction. This provides an average shielding of 3600m w. e. [14, 15]. The remaining muon rate is O(1h-1m-2) [14], i.e. it is reduced by about six orders of magnitude compared to sea level.

The remaining muons can induce background events in detectors, either by direct interaction with the target crystal, or by producing secondary particles in their interactions with rock or the material of the experimental setup, e.g. bremsstrahlung or highly energetic neutrons by muon-induced spallation. To be able to reject muon-related events, CRESST is equipped with a muon veto (see Fig. 2). The veto consists of 20 plastic scintillator panels, read out by photomultiplier tubes and covering 98.7% of the solid angle around the detectors. The reason why the coverage is not 100% is that an opening is needed on the top to leave space for the cryostat. If the muon veto triggered, all events recorded by cryogenic detectors, within a time window of ±2ms, are rejected in the offline analysis.

Cosmogenic activation

Long-lived radioactive impurities in the detector material might be activated due to its exposure to cosmic rays before being brought underground [16]. For CaWO4, lines caused by the decays of cosmogenically activated nuclides below 80keV are reported in [1, 2, 4, 17].

Four lines can be detected due to cosmogenic activation of 182W via proton capture. With a half-life of T1/2=1.82year [18] the resulting 179Ta then decays in the target material by electron capture (EC), leading to the occurrence of the X-ray line as follows:

graphic file with name 10052_2019_7385_Equ1_HTML.gif 1

Since the decay happens in the target crystal the entire atomic de-excitation is measured. The signature of the EC therefore is a line at the binding energy of the respective captured shell electron of 179Hf. Peaks originating from this decay can be seen at energies of 2.60keV (M1 shell), 10.74keV (L2 shell2), 11.27keV (L1 shell) and 65.35keV (K shell) [4].

Another nuclide, 183W, is cosmogenically activated through 183W(p,3H), resulting in 181W. This then decays with T1/2=121.2d [18] into an excited state of 181Ta through EC and it de-excites with the emission of a 6.2keV γ-ray:

graphic file with name 10052_2019_7385_Equ2_HTML.gif 2

Due to the slow detector response, the γ-ray and the atomic de-excitation cannot be resolved. The most prominent peak for this decay is thus observed at 73.6keV which is the sum of the binding energy of the K shell electron of tantalum with an energy 67.4keV and 6.2keV from the subsequent nuclear de-excitation [17].

A nuclide which can be cosmogenically produced in a wide range of target materials is 3H [20]. It is hard to be observed experimentally for CaWO4 in CRESST, since the β-spectrum of 3H is buried below the other low-energy background components. However, Eq. (2) indicates that the observed 181W should be accompanied by a 3H component. Other reaction paths to create 3H in CaWO4 may also be possible.

Ambient γ-radiation

Another type of background are ambient γ-rays, originating from the rock and concrete of the LNGS. The sources of this radiation are γ-decays from the natural radioactive decay chains of 232Th, 235U and 238U, but also individual radioactive nuclides like 40K. The integrated γ-ray flux in hall A of LNGS for energies below 3MeV was measured to be (0.28±0.02)cm-2s-1 [21].

To shield the experiment against this radiation, CRESST detectors are surrounded by an external lead shielding with a mass of 24tonnes and a thickness of 20cm (see Fig. 2). With its high density and atomic number, lead is ideally suited to absorb γ-rays. However, it is not a very radiopure material, in particular its naturally occurring radioactive isotope 210Pb contributes to the background observed in the experiment. Therefore, CRESST lead was produced by the Swedish company Boliden3 with a low 210Pb contamination of 35Bqkg-1 [22]. In addition, an internal lead shielding is placed inside the cryostat directly below the mixing chamber and consisting of 330kg of lead produced by the company Plombum4 in Poland with an even lower 210Pb contamination of only 3.6Bqkg-1 [22]. To reduce any remaining γ-background coming from the lead, low-background copper with a mass of 10tonnes and a thickness of 14cm is placed between the cold box, which contains the detectors, and the lead shielding (see Fig. 2). All the copper used in the experiment is so-called NOSV copper, produced by the Norddeutsche Affinerie AG.5 Copper is still a good gamma attenuator and in contrast to lead it can be produced with a very low level (<1mBqkg-1) of internal radioactivity as it has no naturally occurring radioactive isotopes. This makes copper a more favourable shielding material closer to the detectors.

In addition, copper is also used for structures inside the cold box, such as holders for the detectors of the CRESST experiment due to its good thermal conductivity. The ambient γ-flux is reduced to negligible amounts by the described shielding structure. However, even if copper can be produced with low contamination levels, it remains a non-negligible background source due to its proximity to the detectors and large overall mass [4].

Internal contamination of CaWO4

All CaWO4 crystals in CRESST-II phase 1 and most in phase 2 were commercial crystals produced by the Scientific Research Company “Carat”6 and the Prokhorov General Physics Institute of the Russian Academy of Sciences.7 The contamination of these crystals by α-emitters from the natural decay chains in the energy range between 1.5 and 7MeV was measured to be between (3.05±0.02)mBqkg-1 and (107.13±0.14)mBqkg-1 [23]. Even though the energies of α-decays are above the ROI for the DM searches, the subsequent decay chains contain also β/γ-decays that deposit energy in the ROI.

To reduce the intrinsic background, it was decided to produce crystals within the collaboration [23] using a Czochralski furnace dedicated to growing only CaWO4 crystals [24]. This approach allows one to control all production stages to prevent contamination during crystal growth and after-growth treatments. One of these self-grown crystals was used for the detector module TUM40 (see Fig. 3). In comparison with commercial crystals, a factor of 2–10 decrease in the β/γ-background in the energy range of 1-40keV for TUM40 was achieved. The β- and γ-emissions, e.g. caused by the decay of 210Pb, are also reduced since they originate from the same natural decay chains as the measured α-decays.

Even though the amount of background reduction with TUM40 is significant, there still remains a non-negligible amount of β/γ-background at low energies. Hence, it is of great importance to understand the contribution of each background source using the experimental data at hand. The knowledge of background components also helps to guide the efforts of background reduction.

The reference data sets

As experimental reference for the simulation model described in Sect. 3, we are using the complete data8 recorded with the TUM40 module during CRESST-II phase 2 with a gross exposure of 129.9kgday. This data set contains an average gross rate in the region 1–40 keV of about 3.1kg-1keV-1day-1. If the deposited energy is high enough, the detector gets into normal conducting state and the recorded pulses are saturated. Hence, the standard energy calibration, which is based on the determination of the pulse amplitude, is less precise for high energies [25]. Therefore, we are using three separated data sets: low, medium and high. The main properties of these reference data sets are listed in Table 1.

Table 1.

Properties of reference data sets: energy range of measured data before E and after rescaling E, signal survival probability ε, and net number of background events N

Data sets E (keV) E, (keV) ε(%) N
Low 0.6–500 0.6–495 85b 19005
Medium 500–4000 511–2800 98.1 25091
High 4000–7000 4000–7000a 86.5 30590

a The high-energy reference data set did not require rescaling.

b The signal survival probability is energy independent only above 92.36keV. For the energy dependence at lower energies see Fig. 4

To get the energy spectra for each data set different types of cuts are applied: a rate and stability cut, a coincidence cut, a carrier cut, quality cuts and RMS cuts (see [5] for details). A detailed description of the cut types and their purpose are given in [25]. Successively applying the cuts used in the analysis gives the energy-dependent signal survival probability ε. The latter is evaluated from simulated events as described in [25] and shown in Fig. 4. For the medium- and high-energy data sets the survival probabilities are energy independent and listed in Table 1.

Fig. 4.

Fig. 4

Signal survival probability for the low-energy reference data. Up to the energy of 92.36keV, the signal survival probability is energy dependent; above this energy, it is set to the constant value of 85.0 %

The lower energy limit of the low-energy data set is the threshold of the TUM40 detector module of 0.6keV [3], whereas the upper limit marks the point at which saturation effects cannot be compensated reliably anymore by the applied energy reconstruction. With respect to the DM analysis [25] of this data set the cuts were adjusted to expand the usable energy range to 500keV. However, the lower limit we increase as below 1keV events occur of unknown origin. As their modelling is beyond the scope of this work, we disregard the events in the 0.6–1 keV range. Hence, hereafter ROI refers to the energy range 1–40 keV. Within this ROI we count 11145 background events in TUM40, resulting in the total net rate RTUM40=2.2kg-1keV-1day-1 using the signal survival probability ε (see Fig. 4).

The energy scale of the reference data set agrees well with the literature values of identified peaks for low energies, i.e. in energy range relevant for DM search that is 0.6–40 keV for TUM40 [3]. For energies above 250keV, the energy scale starts to deviate by more than 1keV as expected due to the non-linearities [5]. To correct this shift in the low- and medium-energy data sets, a rescaling is performed via a cubic polynomial. The values of the free parameters are determined by minimising the deviation between the measured energy and the literature value of identified peaks (see [5] for details).

The high-energy reference data set includes sharp peaks which originate from α-decays within the 232Th, 235U and 238U decay chains (see Fig. 5c) mainly as bulk contamination. Besides the full absorption lines, also an escape peak around 4.5MeV due to 230Th (Q=4769.8keV, Eγ=253.7keV) and 235U (Q=4678keV, Eγ=185.2keV) decays is visible, labelled escape line. In addition to bulk contamination, also a peak due to near-surface decay of 210Po is visible, labelled external. Due to the applied cuts, pile-up events caused by the correlated decays 212Bi212Po, 214Bi214Po, and 219Rn215Po, which were observed in [4, 23], are not included in the reference data. Because of the non-linearity of the TES, the calibration was corrected by assigning Q-values from literature [18] to well identified peaks and interpolate linearly between them. The spike in the middle of the 211Bi peak (see Fig. 5c) is an artefact of the energy calibration9 of the data.

Fig. 5.

Fig. 5

Reference data after rescaling for a the low-energy (0.6–495keV), b the medium-energy (511–2800keV) and c the high-energy (4000–7000keV) range. For all three histograms the bin size is 1keV. Triangles indicate peaks used for the normalisation of the simulation in this work, for details see text

As the electromagnetic background components clearly dominate the total background [3, 4, 13], we do not take into account e.g. neutron induced nuclear recoils as background. Therefore, no differentiation between the β/γ-band and the nuclear recoil bands is needed. Hence, we neglect the light yield information in the reference data set and will compare our background model to energy spectra of the total background. The final spectra for the three reference data sets are shown in Fig. 5. The medium- and high-energy data sets are used to normalise the background model which will be described in Sect. 4. The low-energy data set is used to cross check the accuracy of the model and to determine the background contribution in the ROI which will be discussed in Sect. 5.

Simulation of the background spectra

For an accurate simulation of the background spectra, hereafter called spectral templates of individual decays, we use a two-stage approach: for the microscopic simulation of the energy deposition in the detector parts we use a Geant4-based simulation code. To apply the detector response we process the simulated data with a ROOT-based tool [26]. This approach has the advantage that changes in the detector parameters do not require one to rerun the often time-consuming Geant4 simulations.

Furthermore, as we exclude pile-up events from the experimental data (see Sect. 2.4), we are allowed to split decay chains X1X2X3 into piece-wise decays X1X2, X2X3, ...This has the advantage that the activities A1, A2, ...associated with nuclides X1, X2, ...stay free and can be normalised to calibration or assay measurements without the need to rerun the simulations (see Sect. 3.3).

Implementation of detector geometry and physics

For this work we greatly extended the simulation tool ImpCRESST [27] and adapted it for Geant4 version 10.2 patch 1 to simulate the decay of the primary contaminants, the production of the resulting secondary particles, the tracking of all particles through a detector geometry, and the energy deposition in the instrumented detector parts. To obtain reliable simulation results we adjusted the physics list to sub-keV energies, implemented a detailed geometry of our detector, and verified the decay properties of the contaminants as primary input to the simulation.

We use the physics list Shielding as provided by Geant4 with the following three modifications:

(i) Instead of the standard physics constructor G4EmStandardPhysics, we chose G4EmStandardPhysics_option4 because it provides the most accurate modelling of electromagnetic interactions at low energies [28].

(ii) As production cut for secondaries, we set a value of 250eV throughout all volumes.10 If the kinetic energy of a potential secondary drops below this value, no actual secondary is simulated but energy conservation is obeyed by locally depositing the energy. By choosing this low value for the production cut, we consider the leakage of radiation out of the finite detector volume via secondary radiation to a high accuracy. Regardless of this production cut, secondary particles caused by atomic de-excitation, e.g. fluorescence photons and Auger electrons, are produced in any case.

(iii) Radioactive decays are handled by the G4RadioactiveDecayPhysics module. As described in [29], we patched the code to correctly treat 3H as unstable. We note that for a proper simulation of the 234Th-decay, the most prominent internal background source for the target crystal, at least Geant4 version 10.2 is needed.

The modelled geometry is shown in Fig. 6 and reflects closely the shape and size of the actual detector module TUM40 (see Fig. 3a). In particular, we considered the block-shaped target crystal made of CaWO4 which is held by sticks of the same material and copper parts. The target is faced by the light detector which is approximated as pure sapphire (Al2O3), contrary to the SOS used in reality. We omit the silicon layer of 1μm-thickness on the back side of the light detector in the simulation because of its negligible mass contribution. With the same argument we omit both TESs, the wires, and the bronze clamps from the outside pushing the CaWO4 sticks.

Fig. 6.

Fig. 6

Cut-away view parallel to the XZ-plane of the TUM40 detector module as implemented in Geant4

Both the target crystal and the light detector are surrounded by the scintillating foil, which we approximate with Mylar (C10H8O4) foil in the simulation. We consider the ring holding the foil, which is made out of plastic scintillator BC408, and the bronze clamps, which hold the light detector. The properties of the simulated materials are listed in Table 2. For all elements, we assume a natural isotopic abundance.

Table 2.

Chemical composition, total mass per detector part, and material density as implemented in the simulation

Detector part Composition Mass (g) Density (gcm-3)
Copper parts Cu 469.2 8.92
Target crystal CaWO4 246.2 6.01
Holder sticks CaWO4 2.5 6.01
Light detector Al2O3 2.5 3.99
Scintillating foil C10H8O4 1.3 1.37
BC408 ring C10H11 1.3 1.03
Bronze clampsa 6% Sn + 94% Cu 0.4 8.82

a Composition given by mass fractions

For this work, we only record the Geant4 hits in the target crystal for which we store the deposited energy Edep and the time information t.

Emulation of the detector response

To emulate the finite time and energy resolution of the detector, we apply an empirical detector response model to the outcome of the Geant4 simulation. To consider the time resolution of the detector, we sum up all Geant4 hits which happen within Δt with respect to the first hit of a simulated decay to create one experimental event with energy Edep. If hits happen after t+Δt, e.g. via a delayed decay of an isomeric state, the next experimental event will be immediately created. This procedure is applied until all detector hits are processed. We found that Δt=2ms describes the experimental data well. We note that this is a purely empirical approach and does not trivially correspond to length, rise time, dead time etc. of the experimental detector pulses. As described in Sect. 2.4, the reference data contains none of the correlated decays, hence also the simulation omits them.

For each energy deposition Edep of an event, we calculate the observable energy Eobs by randomly sampling a Gaussian G(Eobs;Edep,σ(Edep)) centred at Edep. The energy-dependent variance was obtained from fitting cubic polynomials to the experimental detector resolution via reference data sets in the low- (σl), medium- (σm), and high- (σh) energy range (for details see [5]). The effect of the finite energy resolution is clearly shown on the example of the 223Rn decay spectrum in Fig. 7.

Fig. 7.

Fig. 7

Simulated energy deposition inside the CaWO4 target crystal caused by a bulk contamination with 223Ra without (red histogram) and with (blue histogram) applied detector response model. The maximum of latter histogram is scaled to the maximum of former; bin size is 10keV

Simulation of spectral templates

A spectral template TviX(Eobs) is a probability density function (PDF) which gives the probability to observe an experimental event with energy Eobs in the instrumented volume i, caused by a bulk contamination X in volume v. Hence, it has to be scaled to the contamination level to give the total number of background events. We obtain it in five steps: (i) we sample the volume v homogeneously Nv,X-times, each time placing a nuclide of type X at rest; (ii) in ImpCRESST the decay XY of the nuclide is simulated; (iii) the detector response model is applied; (iv) we count how many of the decayed nuclides lead to an energy deposition Eobs in volume i: ni(Eobs); (v) we obtain TviX(Eobs)=ni(Eobs)/Nv,X. Assuming that the counting of ni(Eobs) is a Poisson process we define its statistical uncertainty as ni(Eobs) and propagate it for all the dependent quantities.

As an example, Fig. 8 shows the sum of the two spectral templates which describe the β-decay of 234Th: either directly or indirectly, the decay reaches the isomeric state 234Pam[73.92keV] (cf. the level scheme in Fig. 8). Due to the long half-life of this state (T1/2=1.159min [18]) compared to the time resolution of the detector O(ms), the decay cascade results in two detector events: one containing the interactions before reaching the isomeric state and one afterwards.

Fig. 8.

Fig. 8

Simulated decay of 234Th with applied detector response model. Due to the isomeric state 234Pam[73.92keV] the decay results in prompt (orange, blue, and red filled histograms) and delayed (violet filled histogram and green peak at 73.92keV) detector events. The bin size is 100eV. For details see text; data for the level scheme are taken from [18]

The isomeric state can be reached via four branches: once via a direct β-decay (orange filled histogram in Fig. 8) and three times via a β-decay to a state at energies above the isomeric state with a subsequent γ-decay to the isomeric state (blue and red filled histograms in Fig. 8). Due to the slow detector response, the γ-decay cannot be resolved and the pile-up results in a β-spectrum shifted to the energy of the associated γ-line as obvious for the blue and red filled histograms.

In 0.16 % of the cases the 234Pam[73.92keV] state decays to the ground state of 234Pa,11 resulting in a monochromatic line at 73.92keV as the second detector event [18] (green peak in Fig. 8). In the remaining 99.84 % of the cases, the isomeric state undergoes a β-decay to the ground state of 234U [18] resulting in a β-spectrum with an endpoint of 2.27MeV as the second detector event (violet filled histogram in Fig. 8).

As described in Sect. 2.3.2 one cosmogenic background source is the EC decay of 179Ta. However, we found that Geant4 assigns the same capture probability regardless from which atomic shells the electron is captured contrary to e.g. [19]. To mitigate this contradiction, we disentangle the spectral templates for the individual atomic shells and determine their activity from a fit to the reference data (see Table 11 for the resulting activities), i.e. we do not rely on the contradicting literature values by leaving the capture probability unconstrained. We disentangle the cumulative decay spectrum, as simulated by Geant4, into individual components by selecting the events according to the total energy of all decay products including the recoiling 179Hf nucleus. Figure 9 shows the resulting spectral templates, i.e. each histogram is normalised to integral one. We note that each atomic shell not only leads to a peak at the fully absorbed electron binding energy of 179Hf, but may also causes escape peaks. This is clearly visible for the K shell (Fig. 9, grey histogram) with a peak caused by the fully absorbed binding energy of 65.35keV [19] and escape peaks nearly coinciding with peaks of the fully absorbed binding energies of the L2, L3, and M3 shells.

Table 11.

Gaussian fit values (mean E, amplitude A and variance σ) of cosmogenic X-ray lines observed in the experimental data of TUM40 for the CaWO4 crystal. The number of observed events (NX-ray,obs) and the corresponding activities (AX-ray) are calculated from the integral of the fit. The statistical uncertainties for NX-ray,obs and AX-ray are calculated using the fit values as described in the text. Based on simulations, η is the ratio between the activities of the photo peak AX-ray and the complete spectrum Atotal

Nuclide E(keV) Amplitude σ(keV) NX-ray,obs(#) AX-ray ± δstat ± δsys (μBqkg-1) η Atotal ± δstat ± δsys (μBqkg-1)
179Ta(M1) 2.620 ± 0.007 163 ± 12 0.094 ± 0.006 384 ± 38 49.8 ± 0.3 ± 5.0 1. 49.8 ± 0.3 ± 5.0
179Ta(L2) 10.83 ± 0.02 37 ± 16 0.09 ± 0.04 83 ± 50 10.59 ± 0.04 ± 6.41 0.9997 10.59 ± 0.04 ± 6.41
179Ta(L1) 11.333 ± 0.004 408 ± 18 0.097 ± 0.006 991 ± 76 126.2 ± 0.5 ± 9.7 0.9998 126.2 ± 0.5 ± 9.7
179Ta(K) 64.994 ± 0.008 233.1 ± 7.8 0.264 ± 0.006 1541 ± 64 170.6 ± 0.8 ± 7.0 0.9719 175.5 ± 0.8 ± 7.2
181W 73.49 ± 0.05 19.6 ± 1.9 0.51 ± 0.04 249 ± 30 27.0 ± 0.2 ± 3.2 0.4873 55.5 ± 0.4 ± 6.6
3H 40.7 ± 0.1 ± 4.8a

a The activity of 3H is calculated via the activity of 181W. See text for details

Fig. 9.

Fig. 9

Simulated energy deposition in CaWO4 caused by EC of 179Ta separated according to the involved atomic shells. The inset shows a zoom to the EC peaks for the M and L shells. The bin size is 1eV

Normalisation of background contributions

The next step is to scale these resulting templates according to the experimental reference data. After the scaling, these individual contributions are combined and compared to the reference data.

Determination of the internal radiogenic background components

Since it is complicated to disentangle each β-decay or Compton continuum as they overlap with each other, we correlate these spectra in the ROI to clearly defined α lines in the energy range between 4 and 7MeV. The connection between the α lines in the MeV range and the β/γ-decays in the keV range comes from secular equilibrium [31]. We omit the α lines of 147Sm and 180W which were observed in an earlier analysis [4] as they are not connected to decays in the ROI.

In this work, we use two requirements for the existence of secular equilibrium: (i) the relative difference of the activities of the parent A and the daughter B has to be (AA-AB)/AA<1% after 460 days had passed, which is the time elapsed between the crystal growth and its arrival underground. (ii) We assume that the initial activity AB(time=0) of the daughter nuclide is negligible if it decays to less than 10 % over time before measurement. If both of these requirements are fulfilled, we consider the parent and the daughter to be in secular equilibrium, so their activities are the same, otherwise, their activities are determined independently.

After identifying the α peaks in the high-energy reference data (see Sect. 2.4), we determine the number of events within a given peak X of amplitude A~ and width σ by fitting a non-normalised Gaussian. Hence, the total number of observed events NX,obs of the α line X is A~·exp(-E2/(2σ2)). We consider the fit uncertainty of A~ and σ as a systematic uncertainty with respect to this MC study and propagate it as absolute systematic uncertainty for all the dependent quantities. We ignore any potential correlations between the fitted parameters A~ and σ. For the total uncertainty we linearly combine this systematic uncertainty with the previous introduced statistical uncertainty of the simulated templates. From the total number of observed events, the activity of the α line X is calculated as:

AX=NX,obsεh·T·M, 3

where T·M stands for the exposure, M is the mass of the CaWO4 crystal (see Table 2), T is the live-time and εh stands for the signal survival probability of the high-energy reference data set (see Sect. 2.4). The obtained activities are listed together with the fit parameters in Table 6 in Appendix A.

Table 6.

Gaussian fit values (mean E, amplitude A and variance σ) of the alpha lines observed in the high-energy reference data of TUM40 for the CaWO4 crystal. The number of observed events (Nα,obs) and the corresponding activities (Aα) are calculated from the integral of the fit. The statistical uncertainties for Nα,obs and Aα are calculated using the fit values as described in the text

Nuclide E (keV) Amplitude σ (keV) Nα,obs (#) Aα ± δstat ± δsys (μBqkg-1)
232Th 4081.6 ± 0.9 4.9 ± 0.6 8.7 ± 0.6 106 ± 15 10.93 ± 0.09 ± 1.52
238U 4270.42 ± 0.09 426.7 ± 5.2 9.74 ± 0.07 10420 ± 150 1073.2 ± 8.7 ± 15.4
235U 4670.3 ± 0.7 12.8 ± 0.8 13.8 ± 0.5 442 ± 31 45.5 ± 0.6 ± 3.2
230Th 4767.1 ± 1.0 11.3 ± 0.7 17.6 ± 1.0 497 ± 43 51.2 ± 0.5 ± 4.4
234U 1085.5 ± 9.8 ± 14.9a
226Ra 66.1 ± 0.7 ± 5.0a
231Pa 5141.6 ± 0.7 11.7 ± 0.7 14.8 ± 0.5 436 ± 30 44.9 ± 0.5 ± 3.1
210Po 5402.7 ± 1.1 6.7 ± 0.5 19.0 ± 0.9 321 ± 27 33.1 ± 0.3 ± 2.8
228Th 5520.6 ± 1.9 5.1 ± 0.5 19.3 ± 2.0 247 ± 33 25.4 ± 0.3 ± 3.4
222Rn 5590.5 ± 0.9 14.2 ± 0.8 18.0 ± 1.0 642 ± 49 66.1 ± 0.7 ± 5.0
224Ra 5789.9 ± 1.8 4.2 ± 0.3 29.0 ± 1.5 302 ± 27 31.1 ± 0.4 ± 2.8
223Ra 5970.1 ± 0.6 24.6 ± 0.9 21.2 ± 0.5 1309 ± 55 134.8 ± 2.3 ± 5.6
218Po 66.1 ± 0.4 ± 5.0a
227Th 141.7 ± 2.3 ± 8.5a
220Rn 6407.7 ± 2.4 2.02 ± 0.23 25.3 ± 2.0 128 ± 18 13.2 ± 0.2 ± 1.8
211Bi 6751.1 ± 0.5 30.05 ± 0.97 19.0 ± 0.4 1428 ± 54 147.1 ± 1.6 ± 5.5

a The peaks 234U/226Ra and 218Po/227Th coincide with each other and form singular peaks. Activity of one of the two alpha lines per peak is obtained via secular equilibrium. The activity of the other alpha line is calculated by subtracting the activity of the line deduced via secular equilibrium from the activity of the whole peak

To compare the simulation results with the reference data (see Fig. 5c), the templates of the individual α-decays were scaled with their respective activities and combined (see Fig. 10). The resulting ratio of the integral of counts in the simulated spectrum to the counts in the experimental data between 4 and 7MeV is (97.8±3.8)%. The uncertainty band shown in Fig. 10 includes both statistical and systematic uncertainties from the simulated templates and the fit of the reference data, respectively.

Fig. 10.

Fig. 10

Comparison of simulated α-spectrum (red, without the external 210Po contamination at 5.3MeV) and the experimental energy spectrum of TUM40 (black). Light blue shows the band of statistical and systematic uncertainties multiplied by a factor 10 for better visibility. The bin size is 10keV

The next step is to determine the activities AY,pred(β) of the β/γ-decaying nuclides Y, which are in secular equilibrium with their α-decaying parents X:

AY,pred(β)=AX·B.R.XY, 4

where B.R.XY is the cumulative branching ratio between the nuclides X and Y. For the comparison between the predicted count spectrum and the observed one in Sect. 5 we also calculate the number of observable predicted events NY,pred(β) as:

NY,pred(β)=AY,pred(β)·εl·T·M, 5

where εl stands for the signal survival probability of the low-energy reference data set. The breakdown of the decay chains with respect to the piece-wise secular equilibrium are given in Appendix A. in Tables 7, 8 and 9. The tables list also the activities as determined for the CaWO4 crystal of TUM40.

Table 7.

An overview of the nuclides of the 238U decay chain. Decay modes, cumulative branching ratios B.R. with respect to the head of the chain, half-lives and activities are included [18]. Nuclides presented in the same cell are in secular equilibrium. Activities of each nuclide are given with systematic errors as deduced in this work for the CaWO4 crystal of TUM40

Parent Mode B.R. (%) Half-life A ±δstat±δsys (μBqkg-1)
238U α 100 (4.468±0.006)·109 year 1073.2±8.7±24.1
234Th β- 100 (24.10±0.03) day 1073.2±64.3±15.4
234Pa β- 100 (6.70±0.05) h 1073.2±99.9±15.4
234U α 100 (2.455±0.006)·105 year 1085.5±9.8±24.7
230Th α 100 (7.54±0.03)·104 year 51.2±0.5±4.8
226Ra α 100 (1600±7) year 66.1±0.7±5.7
222Rn α 100 (3.8235±0.0003) day 66.1±0.7±5.7
218Po α/β- 100 (3.098±0.012) month 66.1±0.4±5.4
214Pb β- 99.98 (27.06±0.07) month 66.1±4.4±5.0
218At α 0.02 (1.5±0.3) s 0.014±0.003±0.001
214Bi α/β- 99.98 (19.9±0.4) month 66.1±14.0±5.0
210Tl β- 0.021 (1.30±0.03) month 0.014±0.004±0.001
214Po α 99.979 (164.3±2.0)μs 66.1±17±5.0
210Pb α/β- 100 (22.20±0.22) year 33.1±0.4±2.8
206Hg β- 1.9×10-6 (8.32±0.07) month (63.0±4.7±5.3)·10-6
210Bi α/β- 100 (5.012±0.005) day 33.1±2.3±2.8
206Tl β- 1.33×10-4 (4.202±0.011) month 0.0044±0.0004±0.0004
210Po α 100 (138.376±0.002) day 33.1±0.3±3.1

Table 8.

An overview of the nuclides of the 235U decay chain. Decay modes, cumulative branching ratios B.R. with respect to the head of the chain, half-lives and activities are included [18]. Nuclides presented in the same cell are in secular equilibrium. Activities of each nuclide are given with systematic errors as deduced in this work for the CaWO4 crystal of TUM40

Parent Mode B.R. (%) Half-life A±δstat±δsys (μBqkg-1)
235U α 100 (7.04±0.01)·108 year 45.5±0.6±3.7
231Th β- 100 (25.52±0.01) h 45.5±1.7±3.2
231Pa α 100 (3.276±0.011)·104 year 44.9±0.5±3.7
227Ac α/β- 100 (21.772±0.003) year 143.5±2.6±4.7
223Fr α/β- 1.38 (22.00±0.07) month 2.0±0.1±0.1
227Th α 98.62 (18.697±0.007) day 141.7±2.3±10.8
223Ra α 99.9999 (11.43±0.05) day 134.8±2.3±7.9
219At α/β- 8.28×10-5 (56±3) s (12.4±1.3±0.4)·10-5
215Bi β- 7.75×10-5 (7.6±0.2) month (11.3±0.8±0.4)·10-5
219Rn α 99.9999 (3.96±0.01) s 134.8±34.2±5.6
215Po α/β- 100 (1.781±0.005) ms 134.8±13.8±5.6
211Pb β- 99.9998 (36.1±0.2) m 134.8±10.3±5.6
215At α 2.3×10-4 (0.10±0.02) ms 0.031±0.008±0.001
211Bi α/β- 100 (2.14±0.02) month 147.1±1.6±7.1
207Tl β- 99.724 (4.77±0.03) month 146.7±11.4±5.5
211Po α 0.276 (0.516±0.003) s 0.41±0.10±0.02

Table 9.

An overview of the nuclides of the 232Th decay chain. Decay modes, cumulative branching ratios (B.R.) with respect to the head of the chain, half-lives and activities are included [18]. Nuclides presented in the same cell are in secular equilibrium. Activities of each nuclide are given with systematic errors as deduced in this work for the CaWO4 crystal of TUM40

Parent Mode B.R. (%) Half-life A±δstat±δsys (μBqkg-1)
232Th α 100 (1.40±0.01)·1010 year 10.9±0.1±1.5
228Ra β- 100 (5.75±0.03) year 10.9±0.2±1.5
228Ac β- 100 (6.15±0.02) h 10.9±1.1±1.5
228Th α 100 (1.9116±0.0016) year 25.4±0.3±3.7
224Ra α 100 (3.6319±0.0023) day 31.1±0.4±3.2
220Rn α 100 (55.6±0.1) s 13.2±0.2±2.0
216Po α 100 (0.145±0.002) s 13.2±3.1±1.8
212Pb β- 100 (10.64±0.01) h 13.2±0.6±1.8
212Bi α/β- 100 (60.55±0.06) month 13.2±2.6±1.8
208Tl β- 35.94 (3.053±0.004) month 4.7±1.2±0.7
212Po α 64.06 (0.299±0.002)μs 8.4±1±1.2

Near external radiogenic background components

The main source of near external radiogenic contamination is expected from the copper holders of the detector modules due to its relatively large mass close to the crystal. This type of background manifests itself in the ROI as β/γ-decays. The copper holders are separated from the crystal by a thin scintillating foil, so even external low-energy βs may be visible in the experimental data. The detector holder of TUM40 is made of NOSV copper from Norddeutsche Affinerie AG (see Sect. 2.3.3), the same copper as used in the CUORE experiment [32]. Under the assumption that both experiments use copper from the same batch [5] we use the upper limits on the bulk activities from [32]: ACu,238U65μBqkg-1, ACu,232Th2μBqkg-1. We found no literature values for the specific activity of 235U in copper. As suggested in [33], we assume the same isotopic abundance as in natural uranium and derive the upper limit: ACu,235U=ACu,238U·0.70%0.46μBqkg-1. Because only activities for the nuclides at the head of the corresponding decay chain are reported in [32] we assume that the chains are in secular equilibrium to obtain the activities for the daughter nuclides. This assumption is supported by measurements of the XENON experiment for another copper batch from the same producer [33].

The mass determines the activity whereas the placement determines what fraction of the activity is visible to the target crystal as background. So, instead of a time-consuming simulation of all contaminants in all copper parts, we simulate the contaminants only in the copper part which has the highest visibility but scale the obtained background spectra to the total mass of all near copper parts. Considering this information, the scaling of the individual decay templates is performed as follows:

NX,pred=Atop·B.R.topX·εl·T·mCu, 6

where Atop stands for the activity of the head of the corresponding decay chain, B.R.topX stands for the cumulative branching ratio between the head of the decay chain and the nuclide X, and mCu stands for the total copper mass (see Table 2). As we use upper limits for the activities to scale the spectral templates, no systematic uncertainties are taken into account; only the statistical uncertainties associated with the simulation of the templates are used.

Additional external radiogenic background components

After removing the contributions of internal radiogenic and near external radiogenic contributions from the experimental reference data, we still observe γ-peaks. These identified lines belong to the decays of nine radioactive nuclides: 40K, 208Tl, 210Pb, 212Bi, 212Pb, 214Bi, 226Ra, 228Ac, and 234Th. Hence, at least for these nine nuclides the total activity of the near copper parts is not enough to explain the observation. It is reasonable to assume that this additional background is caused by parts of the detector modules or shielding structure which have not yet been considered as a source of background in our simulations: massive but more distant copper parts (e.g. thermal shieldings of the cryostat) and/or closer but less massive components of the detector module (e.g. scintillating foil, SOS, TES, wires, bronze clamps). As simulating the complete decay chains in the full experimental setup was beyond the scope of this work, we did a first approximation of the effects of these additional background components. As copper is the most abundant material close to the detectors, we created as a first approximation a 1mm-thick spherical copper shell surrounding the detector module and simulated only these nine clearly identified nuclides as its bulk contaminants. The shell is therefore a very simplified model of the distant copper parts. We note that in reality this background may originate partially also in the other mentioned components; it is up to a future study to identify them.

A consequence of this simplified model is that we do not know the geometrical efficiency, i.e. the probability for a background particle originating in some of these additional components to reach the target crystal. Hence, we can only give the activity A that the crystal would be able to observe if survival probability of the particle was 100 %. The determination of the activity corresponding to the observed γ-lines is very similar to the procedure outlined in Sect. 4.1 for the determination of the activity, i.e. it is the background rate corrected for the signal survival probability. However, there exists a continuous spectrum in the low- and medium-energy ranges which we consider as a linear component of the fit function. In order to get the number of events corresponding only to the γ-peaks, we calculate the number of events Npeak,obs below the Gaussian component of the fit. Consequently, the activity A corresponding to the γ-lines can be calculated using Eq. (3). In order to calculate the activity of the full decay, one has to scale the activity of the γ-peak with η, which is the fraction of events under the γ-peak compared to all the events of the particular decay as calculated from the simulation templates. The total activity of each isotope is then Atotal,obs=Apeak,obs/η. The activity Atotal,obs of the γ-lines, the fraction η and the corresponding decays are listed in Table 10 in Appendix A. In order to predict the observable number of events Ntotal,pred in the low-energy range, we use Eq. (5).

Table 10.

Gaussian fit values (mean E, amplitude A and variance σ) of gamma lines observed in the experimental data of TUM40 and attributed to the additional external radiogenic background. The number of observed events (Nγ,obs) and the corresponding activities (Aγ) are calculated from the integral of the fit. The statistical uncertainties for Nγ,obs and Aγ are calculated using the fit values as described in the text. Based on simulations, η is the ratio between the activity of the photo peak Aγ and the complete spectrum Atotal

Nuclide E(keV) Amplitude σ(keV) Nγ,obs(#) Aγ±δstat±δsys(μBqkg-1) η Atotal±δstat±δsys(μBqkg-1)
208Tl 2615.0±0.3 45.6 ± 3.2 5.8 ± 0.3 332 ± 56 30.1 ± 2.6 ± 2.5 0.052 579.4 ± 49.7 ± 48.7
40K 1460.6±0.3 53.1 ± 5.3 3.4 ± 0.3 228 ± 61 20.7 ± 4.6 ± 2.8 0.11 191.1 ± 42.2 ± 25.7
228Ac 967.8±0.2 107.1 ± 7.9 2.6 ± 0.2 352 ± 66 32.0 ± 2.5 ± 3.0 0.036 881.2 ± 68.0 ± 82.6
212Bi 726.6±0.2 79.4 ± 9.1 1.7 ± 0.2 168 ± 50 15.2 ± 3.0 ± 2.3 0.1 152.6 ± 30.4 ± 22.5
214Bi 608.9±0.1 83.6 ± 6.5 1.7 ± 0.1 356 ± 37 32.3 ± 3.3 ± 3.4 0.14 225.8 ± 23.2 ± 23.7
212Pb 239.8±0.05 614 ± 26 1.30 ± 0.05 1340 ± 120 140.4 ± 6.1 ± 8.2 0.43 325.2 ± 14.1 ± 19.1
226Ra 185.6±0.04 36.3 ± 2.3 0.63 ± 0.04 574.0 ± 4.8 60.2 ± 8.7 ± 5.0 0.58 103.6 ± 15.0 ± 8.7
234Th 92.2±0.04 33.8 ± 2.7 0.45 ± 0.03 377.7 ± 4.0 19.9 ± 2.9 ± 2.1 0.027 744.8 ± 109.6 ± 79.7
210Pb 46.3±0.01 105.2 ± 6.0 0.23 ± 0.01 599.3 ± 4.5 66.8 ± 5.7 ± 5.0 0.784 85.2 ± 7.3 ± 6.4

Determination of internal cosmogenic background components

Internal cosmogenic background components contribute to the overall background in the ROI in the form of β-decay (e.g. 3H) or in the form of X-ray and Auger electron emissions that result from EC (e.g. 179Ta and 181W).

After removing the internal and external (both near and additional) radiogenic background components, the activities of 179Ta and 181W nuclides are determined in the same way as the activities of the external γ-rays (see Sect. 4.3). 3H may be produced via cosmic activation in several ways. However, the only reaction path which is empirically evident for TUM40 is the co-production together with 181W (see Eq. (2)). Hence, we use the activity of 181W to estimate a lower limit on the 3H contamination. A first calculation using ACTIVIA [34] indicated that the activity of 3H is 62 % of the activity of 181W. The activities calculated for each peak and the corresponding nuclide are given in Table 11 in Appendix A.

Discussion of the results

In this section, we first check the self-consistency of our normalisation procedure used in Sect. 3.3 by investigating the compatibility of the medium-energy reference data with the background model. Afterwards, we discuss the background prediction in the ROI and its agreement with the observation. The comparison of the combined model components with the experimental reference data sets are shown in Fig. 11.

Fig. 11.

Fig. 11

Total simulated background spectrum (MC, orange histogram) with statistical (cyan band) and systematic (magenta band) uncertainties with respect to the experimental data with statistical uncertainties (black data points) in the medium-energy range (a), the low-energy range (b), and the ROI (1-40keV) (c). The bin sizes are 1keV, 100eV, and 100eV, respectively

Self-consistency of the simulation

Figure 11a shows the comparison between medium-energy reference data and the combined templates. We obtain the predicted number of background events in the medium-energy range NMC,m by adapting Eqs. (5) and (6) for the discussed background components. The continuous part of the simulated spectrum matches well with the experimental data within the uncertainties.

Besides the γ-lines used to normalise the templates (see Fig. 5), also other prominent γ-lines belonging to nuclides 40K, 208Tl, 214Bi and 228Ac fit well with regards to amplitude and width. This shows the self-consistency of the simulated spectral templates.

To quantitatively compare the simulation with the reference data we define ζ=NMC/Nexp, where Nexp is the number of events in the respective reference data set and NMC is the number of predicted background events. In the following we assume that the near external radiogenic background component reaches the maximum activity that is allowed by the upper limit on the copper contamination (see Sect. 4.2). In the medium-energy range between 511 and 2800keV the reproduction of the background reaches up to ζ=(109±69)%, i.e. the model matches the observed background within the uncertainty.12 The uncertainty is dominated by the limited statistics of the experimental reference data set at medium energies (see Table 1). This limitation can only be resolved by increasing the exposure of the reference data set and is hence outside the scope of this work.

The comparison between model and reference data for the low-energy range is shown in Fig. 11b. The combined peak due to the Kα1 (8.048keV) and Kα2 (8.028keV) fluorescence lines in copper [19] is clearly visible in the experimental data and appears in situ also in the simulated spectrum (see Fig. 11c). As this peak occurs due to the interaction of β/γ-background with the copper, one can consider it as an indicator of the correct estimation of the amount of external contamination. We determine the counts in this peak as described in Sect. 4.3 and give the results in Table 3. Despite the strong simplification of the model used for the distant copper parts, the simulation agrees with the reference data better than a factor two.

Table 3.

Mean energy and counts of the combined Kα1 and Kα2 fluorescence lines of copper in the experimental reference data and the simulation. Rounded to two significant digits on the uncertainty

Mean energy (keV) Counts
Reference data 8.0457 ± 0.0042 180.2 ± 6.4
Simulation 7.9977 ± 0.0026 260.4 ± 6.4

Even though the simulation and the experimental data agree within the uncertainties, it can be seen that the agreement decreases with decreasing energy. This means that we are either missing one or more β/γ-decaying nuclides and/or we are underestimating one or more nuclides considered in this work. If we assume that the match between the simulation and the experimental data in the medium-energy range is correct, then the Q value of the missing nuclide(s) in the low-energy range should be lower than 495keV, which is the upper limit of this energy range.

Background reproduction at low energies

The coverage of the low-energy reference data by the simulation is up to ζ=(79±33)% (see Fig. 11b). The comparison for the energy range between 1keV and 40keV (ROI) (see Fig. 11c), results in up to ζ=(68±16)%. The reduced uncertainty, going down from 33 to 16%, is caused by the increasing statistics in the experimental reference data sets at lower energies. Higher statistics results in smaller uncertainties in the fit of the model components. The decrease of the fit uncertainty, as part of the systematic uncertainty, with decreasing energy is also clearly shown in Fig. 11b, c.

Table 4 lists the activities A and background rates R of individual background contributions as result of our Geant4 model and Fig. 12 shows the related background spectra. The activities represent the background that reaches the crystal as it would be seen by an ideal detector over the full energy range, i.e. the combined energy ranges of the low, medium, and high reference data sets. Considering the real signal survival probability ε for the ROI result in the background rates R which are directly comparable to the experimentally observed RTUM40 (see Sect. 2.4). Normalising the simulated R to RTUM40 yield the relative background contributions ζ which are listed in Table 5 in comparison to a previous work [4].

Table 4.

Modelled activities A for individual background components over the full energy range and the resulting background rate R in the ROI of TUM40. With linearly summed up uncertainties for the total sum. Rounded to two significant digits on the uncertainty

Component A±δstat±δsys(μBqkg-1) R±(δstat+δsys)(kg-1keV-1d-1)
Internal radiogenic
   238U decay chain 4850 ± 220 ± 130 0.3267 ± 0.0016
   235U decay chain 1256 ± 82 ± 64 0.2237 ± 0.0012
   232Th decay chain 155 ± 11 ± 21 0.01843 ± 0.00027
Cosmogenics 458 ± 2 ± 40 0.4123 ± 0.0044
External radiogenic
   Neara 900 ± 250 0.1362 ± 0.0053
   Additional 3290 ± 360 ± 320 0.3848 ± 0.0073
Total sum 10910 ± 920 ± 570 1.502 ± 0.015

a For the activities of near external radiogenic contaminants, the values we use are upper limits. Hence, there are no associated systematic uncertainties and we give only the statistical one

Fig. 12.

Fig. 12

Total simulated background spectrum (MC sum, red) along with the individual contributions from different background components (internal radiogenic (IR, blue histogram), additional external radiogenic (AER, green histogram), near external radiogenic (NER, grey histogram), internal cosmogenic (IC, orange histogram) below 74keV) with respect to the experimental data (black histogram) in the medium-energy range (a), the low-energy range (b), and the ROI (1–40keV) (c). The bin sizes are 1keV, 100eV, and 100eV, respectively

Table 5.

Modelled relative contribution ζ for individual background components of TUM40 in comparison to previous work [4, Table 3] in the energy ROI. Rounded to two significant digits on the uncertainty

Component Relative contribution ζ (%)
Previous work [4] This work
Internal radiogenic 30.4 ± 8.1 26.6 ± 5.0
Internal cosmogenic 17.9 ± 1.1 17.8 ± 3.8
Near external radiogenic 16.9 ± 9.4 6.3 ± 2.1
Additional external radiogenic 3.83 ± 0.49 17.5 ± 4.9
Total sum 69.0 ± 9.2 68.2 ± 15.8

The contribution of 6.3% from the near external radiogenic background is based on the assumption that the copper contamination reaches its maximal allowed value (see Sect. 4.2). In the opposite case, i.e. that the Cu contamination is negligible, our model coverage drops from maximal 68% in the ROI to roughly 62%.

We note that the contribution of the “near external radiogenic contamination” and any “additional external contamination” changed between the previous study [4] and this work (see Table 5): Whereas in [4] the near radiogenic component13 was unconstrained, this work fixed it to the specific activity of the copper (see Sect. 4.2). Consequently, the remaining observed background was shifted to the additional external component. As the contamination in the near copper parts is based on upper limits from literature, the partitioning between near and additional external radiogenic background components may change with the outcome of the ongoing copper assay or/and by including in the simulation more materials as sources of additional background.

It can be seen that internal background is the most prominent component in the ROI which is mostly dominated by radiogenic contaminants. These results indicate that a further purification of the CaWO4 crystal, as planned for CRESST-III phase 2 [35] is an important step towards the reduction of the overall background in the experimental data.

With the first completely Geant4-based electromagnetic background model for the CRESST experiment, we are able to identify and reproduce up to (68±16)% of the background observed using the TUM40 detector module of CRESST-II. This is a methodological independent verification of the (69.0±9.2)% obtained in the previous work [4] which is based on a combination of Geant4-based simulation and a semi-empirical fit to the background data itself. Furthermore, in this work we used all data recorded with TUM40, resulting in a four times higher statistics in the experimental reference data.

Beside this quantitative confirmation, this work features also qualitative improvements over [4]: the simulation of the complete natural decay chains for the intrinsic background component allows us to quantify the background contribution for each nuclide (see Tables 7, 8, 9). Using Geant4 version 10.2 patch 1 allows us to simulate the complete 234Th-decay, whereas in [4] we had to rely on a simplifying workaround as we had to use Geant4 version 10.1. Additionally, we implemented the full geometry of the TUM40 detector module, whereas in [4], only the target crystal was implemented. Hence, in this work, features like the copper fluorescence peak and the external annihilation peak occur naturally in the simulated spectra which had to be added ad hoc or were missing in [4]. These aspects highlight the advantages of using a fully Monte Carlo-based model over a semi-empirical model.

Summary and outlook

Electromagnetic background poses a significant problem for the direct DM search with the CRESST experiment at low energies where the discrimination power between β/γ-events and nuclear recoil-events decreases. To be able to observe a possible DM signal, it is imperative to understand and quantify the background. For this reason, Monte Carlo simulations using a Geant4-based toolkit were performed.

Based on the origin of the contaminants, we divided the background into two categories: internal (inside the CaWO4 target crystal) and external. Internal background includes α- and β/γ-decays of nuclides from the natural decay chains of 232Th, 235U and 238U as well as cosmogenically activated nuclides (179Ta, 181W and resulting 3H). External background includes β/γ-decays from the same natural decay chains and 40K, but originating from copper parts close to the target crystal, e.g. target holder, as well as distant additional parts, e.g. thermal copper shieldings of the cryostat. We scaled the simulated spectra of energy deposits to the activity values obtained from experimental reference data sets. This work, the first fully simulation-based background model for the CRESST experiment, shows that we can reproduce up to (68±16)% of the observed background in the ROI.

The difference between the contributions from internal and external parts demonstrates that the leading contribution to the background comes from the CaWO4 target crystal itself. Based on this result, further purification of the target crystals should remain a high priority for the future. The second most prominent background originates from additional background sources around the target crystal. Hence, more precise knowledge of contamination levels of the used materials will result in a more precise background model.

Consequently, we prepare a dedicated measurement campaign for copper, scintillating foil and silicon-on-sapphire as light detector used in the experiment. In addition we refine the study of cosmogenic activation of CaWO4 to identify potential further cosmogenically produced contaminants. Further improvements are expected from the simulation of the complete set of contaminants in a detailed model of the cryostat and of the shielding, in addition to the highly accurate simulation of the detector module itself which was used in this work. Beyond these studies of electromagnetic background components, we shall also start an in-depth investigation of the neutron background.

Acknowledgements

We are grateful to LNGS for their generous support of CRESST. This work has been supported through the FWF: I3299-N36 and W1252-N27, the DFG by the SFB1258 and the Excellence Cluster Universe, by the BMBF: 05A17WO4 and 05A17VTA and by the APVV: 15-0576.

Appendix A: Tables

Tables 6, 7, 8, 9, 10, 11 list the individual contributions of the investigated background components.

Data Availability Statement

This manuscript has no associated data or the data will not be deposited. [Authors’ comment: The datasets generated during and/or analysed during the current study are available from the corresponding authors on reasonable request.]

Footnotes

1

Product nowadays continued under the name Vikuiti, produced by the company 3M, https://www.3m.com.

2

We note that the L1/L2 ratio does not match the expectation [19], hence there may be a contribution of an unknown background or there are opportunities for future enhancements.

4

Plombum Firma-Laboratorium, ul. Rozrywka 20, 31-419 Kraków, Poland.

5

Aurubis AG since 12 February 2008, https://www.aurubis.com/en.

8

We note that for the DM analysis in [3], only 29.35kgday of these data were used; the uncertainty on the exposures is negligible. For this reduced data set [4] states an average gross rate in the region 1-40keV of about 3.51kg-1keV-1day-1.

9

This is because the “fixpoint” of the polynomial, which is used to map the measured voltage signals to calibrated energies, is the centre of the reference peak. Therefore, events close to this energy deviate less and the peak gets “compressed”.

10

This is the lowest value for which all relevant electromagnetic physics processes are approved. We note that for specialised use cases the applicability limit can be lower, e.g. for elastic electron scattering in silicon as low as 5eV. By default the cut value is 990eV [28].

11

We note that prior to version 10.2, Geant4 did not implement this decay properly [30]: 234Pam[73.92keV] decayed in 100 % of the cases to the ground state of 234Pa, resulting in an overestimation of the monochromatic line at 73.92keV.

12

Including statistical uncertainties from the simulated spectral templates and systematic uncertainties from the fit to the reference data.

13

Called “external β” in [4, Table 3].

Change history

12/4/2019

The original version of this article unfortunately contains mistakes.

Contributor Information

H. Kluck, Email: holger.kluck@oeaw.ac.at

V. Mokina, Email: valentyna.mokina@oeaw.ac.at

C. Türkoğlu, Email: c.turkoglu@sussex.ac.uk

References

  • 1.CRESST, A. H. Abdelhameed et al., (2019), arXiv:1904.00498
  • 2.CRESST, G. Angloher et al., Eur. Phys. J. C 76, 25 (2016), 1509.01515
  • 3.CRESST, G. Angloher et al., Eur. Phys. J. C 74, 3184 (2014), arXiv:1407.3146
  • 4.CRESST, R. Strauss et al., JCAP 1506, 030 (2015), arXiv:1410.4188
  • 5.C. Türkoğlu, Development of a Geant4 Based Electromagnetic Background Model for the CRESST Experiment, PhD thesis, Technische Universität Wien, 2018
  • 6.Agostinelli S, et al. Nucl. Instrum. Methods A. 2003;506:250. doi: 10.1016/S0168-9002(03)01368-8. [DOI] [Google Scholar]
  • 7.Allison J, et al. IEEE Trans. Nucl. Sci. 2006;53:270. doi: 10.1109/TNS.2006.869826. [DOI] [Google Scholar]
  • 8.Allison J, et al. Nucl. Instrum. Methods A. 2016;835:186. doi: 10.1016/j.nima.2016.06.125. [DOI] [Google Scholar]
  • 9.CRESST, M. Kiefer et al., Nucl. Instrum. Meth. A 821, 116 (2016), arXiv:1503.07806
  • 10.Pobell F. Matter and Methods at Low Temperatures. Berlin, Heidelberg: Springer; 2007. [Google Scholar]
  • 11.CRESST, G. Angloher et al., Astropart. Phys. 18, 43 (2002)
  • 12.CRESST, R. Strauss et al., Eur. Phys. J. C 75, 352 (2015), arXiv:1410.1753
  • 13.Angloher G, et al. Eur. Phys. J. C. 2012;72:1971. doi: 10.1140/epjc/s10052-012-1971-8. [DOI] [Google Scholar]
  • 14.MACRO, M. Ambrosio et al., Phys. Rev. D 52, 3793 (1995)
  • 15.LVD, M. Selvi, Analysis of the seasonal modulation of the cosmic muon flux in the LVD detector during 2001-2008, in 31st International Cosmic Ray Conference (ICRC 2009): Lodz , Poland, July 7-15, 2009, pp. 1–4, 2009
  • 16.Cebrián S. Int. J. Mod. Phys. A. 2017;32:1743006. doi: 10.1142/S0217751X17430060. [DOI] [Google Scholar]
  • 17.Lang RF, et al. Astropart. Phys. 2010;32:318. doi: 10.1016/j.astropartphys.2009.09.009. [DOI] [Google Scholar]
  • 18.International Atomic Energy Agency, Nuclear data services, https://www-nds.iaea.org
  • 19.Firestone RB, editor. Table of isotopes. 8. New York: Wiley; 1996. [Google Scholar]
  • 20.Zhang C, Mei DM, Kudryavtsev VA, Fiorucci S. Astropart. Phys. 2016;84:62. doi: 10.1016/j.astropartphys.2016.08.008. [DOI] [Google Scholar]
  • 21.Haffke M, et al. Nucl. Instrum. Methods A. 2011;643:36. doi: 10.1016/j.nima.2011.04.027. [DOI] [Google Scholar]
  • 22.R. F. Lang, Search for Dark Matter with the CRESST Experiment, PhD thesis, Technische Universität München, 2008
  • 23.Münster A, et al. JCAP. 2014;1405:018. doi: 10.1088/1475-7516/2014/05/018. [DOI] [Google Scholar]
  • 24.Erb A, Lanfranchi J-C. Cryst. Eng. Commun. 2013;15:2301. doi: 10.1039/c2ce26554k. [DOI] [Google Scholar]
  • 25.F. Reindl, Exploring Light Dark Matter With CRESST-II Low-Threshold Detectors, PhD thesis, Technische Universität München, 2016
  • 26.Brun R, Rademakers F. Nucl. Instrum. Methods A. 1997;389:81. doi: 10.1016/S0168-9002(97)00048-X. [DOI] [Google Scholar]
  • 27.S. Scholl, Neutron Background Simulation for the CRESST-II Experiment, PhD thesis, Universität Tübingen, 2011
  • 28.Geant4 Low Energy Electromagnetic Physics Working Group, Low energy electromagnetic physics–physics lists, https://new-geant4-dev.web.cern.ch/node/1617
  • 29.M. H. Kelsey, Radioactive decay of tritium, http://hypernews.slac.stanford.edu/HyperNews/geant4/get/hadronprocess/1538/1/1.html
  • 30.D. H. Wright, Decays of Th234/Pa234[73.92]/U234, http://hypernews.slac.stanford.edu/HyperNews/geant4/get/hadronprocess/1459/2.html
  • 31.M.F. L’Annunziata (ed.), Handbook of Radioactivity Analysis, 3rd edn. (Academic Press, Amsterdam, 2012)
  • 32.CUORE, C. Alduino et al., JINST 11, P07009 (2016), arXiv:1604.05465
  • 33.Aprile E, et al. Astropart. Phys. 2011;35:43. doi: 10.1016/j.astropartphys.2011.06.001. [DOI] [Google Scholar]
  • 34.Back JJ, Ramachers YA. Nucl. Instrum. Methods A. 2008;586:286. doi: 10.1016/j.nima.2007.12.008. [DOI] [Google Scholar]
  • 35.CRESST, G. Angloher et al., (2015), arXiv:1503.08065

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

This manuscript has no associated data or the data will not be deposited. [Authors’ comment: The datasets generated during and/or analysed during the current study are available from the corresponding authors on reasonable request.]