Sources of distortion in functional MRI data

Peter Jezzard 1,, Stuart Clare 1
PMCID: PMC6873315  PMID: 10524596

Abstract

Functional magnetic resonance image (fMRI) experiments rely on the ability to detect subtle signal changes in magnetic resonance image time series. Any areas of signal change that correlate with the neurological stimulus can then be identified and compared with a corresponding high‐resolution anatomical scan. This report reviews some of the several artefacts that are frequently present in fMRI data, degrading their quality and hence their interpretation. In particular, the effects of magnetic field inhomogeneities are described, both on echo planar imaging (EPI) data and on spiral imaging data. The modulation of these distortions as the subject moves in the magnet is described. The effects of gradient coil nonlinearities and EPI ghost correction schemes are also discussed. Hum. Brain Mapping 8:80–85, 1999. © 1999 Wiley‐Liss, Inc.

Keywords: functional MRI, distortions, echo planar imaging

Full Text

The Full Text of this article is available as a PDF (312.6 KB).

REFERENCES

  1. Ahn CB, Kim JH, Cho ZH. 1986. High speed spiral‐scan echo planar NMR imaging—I. IEEE Trans Med Imag MI‐5:2–7. [DOI] [PubMed] [Google Scholar]
  2. Irarrazabal P, Meyer CH, Nishimura DG, Macovski A. 1996. Inhomogeneity correction using an estimated linear field map. Magn Reson Med 35:278–282. http://www.ncbi.nlm.nih.gov:80/htbin-post/Entrez/query?uid=96208355&form=6&db=m&Dopt=r [DOI] [PubMed] [Google Scholar]
  3. Jezzard P, Balaban RS. 1995. Correction for geometric distortion in echo planar images from B0 field variations. Magn Reson Med 34:65–73. http://www.ncbi.nlm.nih.gov:80/htbin-post/Entrez/query?uid=95405234&form=6&db=m&Dopt=r [DOI] [PubMed] [Google Scholar]
  4. Mansfield P. 1977. Multi‐planar image formation using NMR spin echoes. J Phys C 10:L55–L58. [Google Scholar]
  5. Meyer CH, Macovski A. 1987. Square spiral fast imaging: interleaving and off‐resonance effects. Proc 6th Soc Magn Reson Med 1:230. [Google Scholar]
  6. Noll DC, Meyer CH, Pauly JM, Nishimura DG. 1991. A homogeneity correction method for magnetic resonance imaging with time varying gradients. IEEE Trans Med Im 10:629–637. [DOI] [PubMed] [Google Scholar]
  7. Weisskoff RM, Cohen MS, Rzedzian RR. 1993. Nonaxial whole‐body instant imaging. Magn Reson Med 29:796–803. http://www.ncbi.nlm.nih.gov:80/htbin-post/Entrez/query?uid=93354076&form=6&db=m&Dopt=r [DOI] [PubMed] [Google Scholar]
  8. Woods RP, Cherry SR, Mazziotta JC. 1992. Rapid automated algorithm for aligning and reslicing PET images. J Comput Assist Tomogr 16:620–633. http://www.ncbi.nlm.nih.gov:80/htbin-post/Entrez/query?uid=92332823&form=6&db=m&Dopt=r [DOI] [PubMed] [Google Scholar]

Articles from Human Brain Mapping are provided here courtesy of Wiley

RESOURCES