Abstract
The widespread industrial use of H2O2 has provoked great interest in the development of new and more efficient materials for its detection. Enzymatic electrochemical sensors have drawn particular attention, primarily because of their excellent selectivity. However, their high cost, instability, complex immobilization, and inherent tendency toward denaturation of the enzyme significantly limit their practical usefulness. Inspired by the powerful proton-catalyzed H2O2 reduction mechanism of peroxidases, we have developed a well-defined and densely functionalized carboxylic graphene derivative (graphene acid, GA) that serves as a proton source and conductive electrode for binding and detecting H2O2. An unprecedented H2O2 sensitivity of 525 μA cm–2 mM–1 is achieved by optimizing the balance between the carboxyl group content and scaffold conductivity of GA. Importantly, the GA sensor greatly outperforms all reported carbon-based H2O2 sensors and is superior to enzymatic ones because of its simple immobilization, low cost, and uncompromised sensitivity even after continuous operation for 7 days. In addition, GA-based sensing electrodes remain highly selective in the presence of interferents such as ascorbic acid, paracetamol, and glucose, as well as complex matrices such as milk. GA-based sensors thus have considerable potential for use in practical industrial sensing technologies.
Introduction
Hydrogen peroxide (H2O2) is widely used in industry; its worldwide production has been projected to reach 6 × 106 tons by 2024, making it among the 100 most important bulk chemicals.1,2 Sectors that use H2O2 extensively include the textile, pulp, paper, semiconductor, food, and cosmetic industries. However, H2O2 is cytotoxic,3 so its presence in commercial products is strictly monitored. Indicative concentration limits range from 12% for hair care products to 0.1% for oral hygiene commodities, and zero-tolerance in food products.4 Moreover, 3–10 wt % solutions of H2O2 in water are used around the world as an antiseptic. Consequently, there is a growing demand for simple, fast, sensitive, and inexpensive sensors for H2O2 detection.
Conventional spectroscopic techniques such as spectrophotometry,5−8 fluorescence spectroscopy,9−11 and chemiluminescence spectroscopy12−16 are highly sensitive but require complex and expensive instrumentation and long detection times. Moreover, spectrophotometric techniques are often incompatible with real samples containing dispersed particles or dissolved species that may scatter or absorb light, affecting the measurement. In contrast, electrochemical methods could potentially enable simple, rapid, sensitive, and cost-effective H2O2 detection, avoiding the major drawbacks of spectroscopic methods.17−20 In principle, electrochemical H2O2 detection could be achieved using a conventional solid-state electrode such as the glassy carbon electrode (GCE). However, this approach is limited by high redox overpotentials and a lack of selectivity, leading to inaccurate determination of H2O2 in real samples. These issues are exacerbated when other electroactive species are present (e.g., ascorbate, urate, glucose, paracetamol, or bilirubin). Therefore, there is an ongoing effort to rationally design new materials for H2O2 detection that combine sensitivity, selectivity, and favorable kinetics with a long life cycle and cost-effectiveness.
One of the most successful approaches resulting from this effort relies on the modification of electrodes with enzymes.21 Because most active sites in enzymes are highly specific for their target reactions, enzymatic sensors are generally very selective. However, they have notable drawbacks including relatively high costs, instability toward variation in temperature and pH, complicated immobilization procedures, and an inherent tendency toward denaturation of the enzyme,22 which hinders their commercial application. Because of these limitations, there is growing interest in non-enzymatic alternatives, many of which incorporate nanostructured metals and metal oxides or hybrids thereof with carbon nanomaterials.23 Carbon materials are widely used in electrochemistry because of their low cost, wide potential window, high stability, conductivity, and remarkable selectivity for diverse redox reactions, including CO2 and O2 reduction.24−34 Their potential as electrochemical sensors is enhanced by their ready modification (in contrast to metal electrodes) and high surface area, which favors analyte adsorption and accumulation.24,35
Both carbon nanotubes (CNTs)36−39 and graphene1,40−43 have thus been used as electrodes for electrochemical H2O2 detection. For example, a H2O2 electrosensor based on chemically reduced graphene oxide (CR-GO)41 reportedly outperformed both CNTs41 and a bare GCE.40 Moreover, the CR-GO system was able to operate at concentrations between 0.05 and 1500 μmol with a sensitivity of 82.35 μA cm–2 mM–1. While GO must be reduced to convert it from an insulator into a conductor, reduction changes the material’s property in some undesirable ways, by increasing its hydrophobicity and removing functional groups. This increases its tendency to aggregate and limits its solvation in water and accessibility to analyte molecules.44,45 To circumvent these problems, Woo et al.46 used MWCNTs as bridges and pillars separating the graphene sheets, creating a conductive network and preventing their aggregation. However, the resulting sensor exhibited a lower sensitivity (32.91 μA cm–2 mM–1) than the original CR-GO system, probably because the surface hydrophobicity and the lack of chemical functionalities for binding H2O2 were not adequately addressed. In another attempt to boost the performance of GO-based electrosensors, Wang et al.47 covalently grafted tyrosine onto GO and simultaneously reduced it by heating at 100 °C for 24 h with no added conjugation agents. The resulting material had a wide linear H2O2 detection range (100 to 2100 μM), a detection limit of 80 μM, and a sensitivity of 69.07 μA cm–2 mM–1, which was still lower than that of pristine CR-GO.
Heteroatom doping offers another way for improving the performance of graphene-based H2O2 sensors. Boron-doped graphene nanosheets were recently reported as carbon-based catalysts for H2O2 detection with a superior sensitivity of 266.7 μA cm–2 mM–1. However, while their linear range is wide (1000–20,000 μM), its lower bound is very high.48 The development of carbon-based catalysts for H2O2 sensing is probably hampered by the dense but uncontrolled functionalization of GO,49 which makes it an insulator, and by the low reactivity of pristine graphene.50,51 Overcoming these challenges will require an up-scalable product combining hydrophilicity with conductivity and selective functionalization for enhanced binding and reduction of H2O2. This could be achieved through controlled derivatization that avoids functional groups that do not contribute to sensing and thus reduce the graphene system’s conductivity without providing any commensurate benefit.
Based on these considerations and the proton-catalyzed H2O2 reduction mechanism of peroxidases,52 we propose a selectively and densely functionalized carboxylic graphene derivative (graphene acid,53 GA) as a two-dimensional proton source and conductive electrode for binding and detecting H2O2. Whereas GO synthesis requires concentrated acids and strong oxidizers, GA is prepared under mild conditions that preserve the graphene sheets’ conductivity and avoid introducing functionalities that are not useful for H2O2 sensing. These properties were exploited to develop a GA-based electrochemical H2O2 sensor with sensitivity as high as 525 μA cm–2 mM–1, setting a new benchmark in the field (see Table S1 for detailed comparisons). Analyses with inductively coupled plasma mass spectrometry (ICP-MS) precluded any metal impurity-induced activity. Remarkably, the GA-based sensor’s sensitivity surpassed that of enzymatic sensors54 while remaining stable even after a week of continuous operation. It was also very robust, retaining high sensitivity and selectivity for H2O2 in the presence of interferents such as ascorbic acid, paracetamol, and glucose, or when tested in complex matrices such as milk.
Results and Discussion
GA was synthesized from fluorographene (FG), a stable, stoichiometric, and well-defined graphene derivative, which was subjected to nucleophilic substitution with NaCN, yielding fluorine-free G-CN with 15% nitrile group coverage.53 The −CN groups were then quite selectively converted into −COOH groups by acid hydrolysis with HNO3, yielding densely functionalized GA.53 By varying the concentration of HNO3 in the acid hydrolysis step, GA samples with varying carboxyl contents (GA1, GA2, and GA3) were obtained. Pristine G-CN displayed a pronounced IR band at 2207 cm–1 (Figure 1A, spectrum i) due to the triple bond of the covalently attached C≡N groups. Upon treatment with 20% HNO3, the C≡N band disappeared, indicating the replacement of the nitrile groups with carboxyls (GA1, Figure 1, spectrum ii). Raising the acid concentration during the hydrolysis step to 40% (GA2) or 65% (GA3) increased the content of −COOH groups, as indicated by the increasing intensity of the band at 1726 cm–1 (Figure 1A, spectra ii–iv). The increasing −COOH content in the GA1–GA3 samples also affected the C=C bands (aromatic ring stretching vibrations),55,56 which appeared at 1580 cm–1 in the G-CN spectrum. Specifically, as the −COOH content increased, the aromaticity and extent of conjugation decreased, leading to a shift of the band to 1607 cm–1. The broad band with maximum intensity centered at 1233 cm–1 is ascribed to in-plane carbon ring and carboxyl vibrations.57
Atomic compositions retrieved from XPS survey analysis showed that acid hydrolysis reduced the samples’ content of nitrogen and increased that of oxygen (Figure 1B). HR-XPS data for the C 1s region also indicated that the increasing O content was attributable to carboxyl-type carbons because of the very characteristic component evolving at 288.7 eV (Figure 1C and inset).58 Additionally, the C≡N component (highlighted in gray in the inset of Figure 1C) of G-CN was absent in the spectra of GA1, GA2, and GA3, all of which had near-identical C≡N regions. This corroborated the IR data, suggesting that almost all nitrile groups hydrolyzed, even in GA1. The O and N contents in the G-CN and GA samples are probably due to the side reactions during the synthesis of G-CN from FG, which is performed in DMF at 130 °C; at this temperature, DMF decomposes into amines that are reactive toward FG.53 The O 1s region of the deconvoluted HR-XPS spectrum of the GA1 sample (Figure 1D) contains two main components (the third minor one is ascribed to chemisorbed O2 and H2O). The main components in GA1 are almost equal in area, which is in agreement with the presence of O=C—OH (carboxyl) groups.59 While acidic hydrolysis of the nitrile groups with HNO3 led to a relatively selective carboxylation in sample GA1, the higher HNO3 concentrations used to prepare GA2 and GA3 induced less selective oxidation of the graphene skeleton, as indicated by the increasing —C=O over the −C–OH component (Figure 1D) and the additional C=O IR bands indicated by asterisks in Figure 1A.
The quality of the sheets in samples GA1–GA3 was probed by HR-TEM (Figure 2A–C and insets). The use of nitric acid concentrations above that required for selective nitrile hydrolysis apparently reduced the graphene skeleton’s integrity: GA2 and GA3 had more small fragments of material and defects than GA1 (Figure 2B,C and insets).The HAADF-STEM image and elemental mapping of carbon and oxygen in the GA1 sample (Figure 2D–G) clearly show the homogeneous and dense atomic distribution of oxygen on its sheets. The higher quality flake structure of the GA1 sample was further probed with scanning electron microscopy (Figure S1).
The electrocatalytic properties of the GA derivatives were evaluated by cyclic voltammetry (CV) in Ar-saturated PBS buffer solution at pH 7.0 because H2O2 is less readily detected at neutral pH than under basic or acidic conditions, making for a more stringent and practically relevant test of performance.60 In all the three investigated cases, an anodic/cathodic couple of broad peaks was detected that was attributed to the redox processes of the carboxyl groups, according to the results described in Figure S3. A significant decline in current density was observed upon moving from GA1 to GA3 (Figure 3A), in agreement with the previous data, regarding the lower aromatic character and sheet quality of GA2 and GA3, since both factors would tend to reduce conductivity. All GA samples exhibited a stronger cathodic current density in the presence of the H2O2 analyte (Figure 3B–D), with an onset potential of −0.15 V after the addition of 5 mM H2O2. This suggested that all GAs were active in H2O2 reduction and thus detection. Nevertheless, the CV scans showed that the current density response at −0.4 V for GA1 (−627 μA cm–2) was much stronger than that for GA2 (−231 μA cm–2) or GA3 (−53 μA cm–2). This confirmed the importance of mild acid treatment (i.e., selective nitrile group hydrolysis). Interestingly, the current density response upon H2O2 addition using GO was marginal, as shown by the very small increase of current density in the CVs upon addition of H2O2 (Figure S2A).
To better understand the electrochemical properties of GA electrodes, we performed EIS measurements using an optimized Nafion-based ink containing the GA samples. The instability of the GA3 ink caused the detachment from the electrode and the leaching in the aqueous solution, preventing its characterization. This was probably due to the very high hydrophilicity of GA3, which resulted from its high content of oxygen groups and defects, as well as its comparatively small flake size (Figure 2C). Based on the Nyquist plots for GA1 and GA2 (Figure 4A) and the corresponding equivalent circuit (EC) used to fit the EIS data, the GA1-modified electrode exhibited a charge-transfer resistance of 8 Ω cm2, three times lower than that of GA2 (Table S2), confirming the importance of conductivity for imparting high performance. In control experiments, the non-carboxylated GA precursor (G-CN) exhibited a worse H2O2 sensing performance with respect to GA1 (Figure S3) despite its higher conductivity, as previously reported.61 The latter is also evidenced here from the lower charge-transfer resistance (R1 = 5 Ω cm2, as simulated from the EIS data in Figure 4A and Table S2) than that of GA1. G-CN also demonstrated lower stability of the response (Figure S4) and a narrower linear range, being unable to operate at concentrations below 0.1 mM H2O2. The electrochemical response of the GA-CN product treated with a lower amount of HNO3 than the GA1 and thus being a mixed-functionalized graphene carrying both −CN and −COOH groups (see IR spectra in Figure S3 inset) was also inferior to GA’s response (Figure S3). These results demonstrated the key role of −COOH groups tethered onto a sufficiently conductive substrate. Indeed, catalytic H2O2 reduction by enzymes (i.e., peroxidases) is triggered by the supply of protons from amino acid residues in the enzyme’s H2O2 binding pocket, together with electron injection from sacrificial donors.52
Furthermore, DFT calculations (Figure 4B–D) indicated that H2O2 binds more tightly to GA (−21.5 kcal mol–1) than to GCN (−10.2 kcal mol–1) or GO (−15.5 kcal mol–1) because strong hydrogen bonds are formed between the OH groups of H2O2 and the carboxylate groups of GA. It should be highlighted that ICP-MS analyses confirmed that metal impurities in the GA1 product are not responsible for any catalytic activity (see Table S3 for results and discussion).
To further evaluate the sensing performance of GA1, we conducted chronoamperometry measurements at −0.4 V versus SCE by sequentially adding 20 μL portions of a 50 mM H2O2 solution to a 10 mL 0.1 M PBS solution (Figure 5A). The value −0.4 V versus SCE was chosen as the working potential as it produced the best response from the sensor in terms of sensitivity and the linear range. Calibration plots for the three samples derived from chronoamperometry data revealed a linear relationship between the current density and the H2O2 concentration over the investigated range (Figure 5B). The obtained values reflect the previously observed trend, with GA1 displaying the highest average sensitivity (525 ± 105 μA cm–2 mM–1), while GA2 and GA3 showed progressively worse performance, with average sensitivities of 94 ± 25 and 40 ± 9 μA cm–2 mM–1, respectively. The high sensitivity of GA1, exceeding that of GA3 by more than one order of magnitude, correlated with its excellent electron transfer properties, which resulted from the optimized synthetic protocol. By repeating the experiment with different concentration windows, we estimated the sensor’s linear range; H2O2 could be detected with the quoted sensitivities at concentrations between 20 and 2000 μM, making GA-based sensors potentially suitable for several biological and industrial applications. Remarkably, the sensitivity of GA1 substantially exceeded that of other recently reported graphene-based sensors:43,46,47 it was twice that of the previous record holder (B-doped graphene,48 with a sensitivity of 266 μA cm–2 mM–1) and even higher than some enzymatic systems.54 A detailed comparison of the performance of state-of-the-art carbon-based sensors is available in Table S1.
GA1 was tested further under conditions more closely resembling real applications to validate its reproducibility/stability, selectivity, and robustness when exposed to real, complex matrices. Its reproducibility and stability in the presence of possible H2O2 degradation products such as oxygen radicals were evaluated by performing amperometric tests at −0.4 V for 7 consecutive days during which its average sensitivity remained unchanged.
Another crucial determinant of a H2O2 sensor’s reliability is its response to interference by oxidizable compounds commonly present in commercial samples such as ascorbic acid, glucose, and paracetamol. Figure 5C shows the amperometric response of GA1 to H2O2 in the presence of these three compounds. The current density increased steeply after the addition of H2O2, but no such increase followed the addition of the interfering substances, demonstrating the high selectivity of GA1 for H2O2. The general robustness and reliability of the GA1 sensor was then evaluated in a realistic test case by adding commercial milk to the electrolyte solution while performing chronoamperometry tests. Milk was chosen because H2O2 is widely used in dairy production to inhibit microbial proliferation and milk spoilage and its concentration must be strictly monitored for safety reasons. Milk is also a complex mixture of different compounds, and it is a particularly demanding system for benchmarking H2O2 sensors. Strikingly, the current density response remained utterly unaffected by the addition of milk (Figure S5). These results clearly showed that GA is a promising candidate for sensitive, selective, cheap, and reliable H2O2 sensors suitable for the testing of commercial products bearing complex matrices.
Conclusions
We demonstrated that graphene acid, a selectively carboxylated and conductive graphene derivative, acts as a carbon-based catalyst for the electroreduction and detection of H2O2 whose sensitivity (525 μA cm–2 mM–1) markedly exceeds that of all previously reported carbon-based sensors and competes even that of enzymatic ones. However, unlike the delicate enzymatic sensors, GA’s sensitivity remained uncompromised over a week of a continuous operation. This unprecedented performance is attributable to its stable carbon-based all-covalent nature, the high affinity of carboxyl groups for H2O2 (as revealed by DFT calculations), and their abundance in the material, which enables the efficient proton-assisted H2O2 electroreduction. When tested in realistic scenarios featuring interfering species and complex matrices such as milk, the graphene-acid electrosensor exhibited high selectivity and retained its sensitivity. Given the material’s proven biocompatibility53 and the availability of a high-yielding and scalable synthetic protocol, these results may pave the way to the development of a previously unexplored class of carbon-based non-enzymatic commercial sensors for H2O2 detection.
Experimental Section
Reagents, Materials, and Methods
Nafion 117 solution (5 wt %), NaCN (p.a. ≥97%), and graphite fluoride (>61 wt % F, C1F1.1) were purchased from Sigma-Aldrich. Acetone (pure) and ethanol (absolute) were purchased from Penta. Amine-free dimethylformamide (DMF) and nitric acid (Analpure, 65%) were obtained from Lach-Ner. All aqueous solutions were prepared with ultrapure water (18 MΩ cm–1).
Synthesis of Cyanographene (Precursor of GA)
Cyanographene (G-CN) was synthesized according to previously reported procedures, with small modifications (see Supporting Information).53
Synthesis of Graphene Acid Samples
Nitric acid was added to aqueous suspensions of G-CN to achieve final HNO3 concentrations of 5, 20, 40, or 65 wt % (for GA-CN, GA1, GA2, and GA3, respectively), and the resulting suspensions were heated at 100 °C with stirring (500 rpm) for 24 h. For the case of GA-CN, reflux was applied for 30 min. The product was isolated and washed with H2O by centrifugation. When it stopped precipitating after a few washing steps, acidic water (pH = 4) was used to protonate the material and reduce its dispersibility, inducing precipitation. Finally, dialysis was applied to obtain stable aqueous suspensions of GA1, GA2, and GA3 with a final pH of ∼3.2 and a suspension conductivity of ∼150 μS cm–1. It is noted that GA1 was synthesized according to ref (53).
Electrochemical Techniques
Electrochemical tests were performed at room temperature using an Autolab 302 N electrochemical workstation (Metrohm). The cell setup was a three-electrode system with a Pt wire as the counter electrode, a saturated calomel electrode (SCE) that was separated from the solution by a bridge equipped with a Vycor frit as the reference electrode, and a GCE modified with the prepared electrocatalysts as the working electrode. The GCE was polished with 1.0 and 0.3 μm alumina powders (Buehler MicroPolish) and rinsed thoroughly with deionized water. The electrode was then dried at 60 °C. The ink (10 μL) prepared from the different materials was then drop-cast on a clean GCE and dried in an oven at 60 °C for 30 min. The inks were prepared at a concentration of 2.5 mg mL–1 using Nafion 1 wt % in a 50:50 ethanol/water solution. The average sensitivity for each sample was determined by repeating the experiment multiple times. For electrochemical impedance spectroscopy (EIS) measurements, see the Supporting Information.
Density Functional Theory (DFT) Calculations
To model the interaction of H2O2 with graphene derivatives, we used finite size models based on functionalized ovalene (C32H14) with a degree of functionalization of 12.5%. Consequently, the GA, GCN, and GO models contained four carboxylate groups, four nitrile groups, and one epoxy and two hydroxyl groups, respectively (cf. Figure 4B–D). All geometries were optimized using the ωB97xd62 long-range corrected hybrid density functional with dispersion correction and Dunning’s correlation-consistent polarized double-ζ basis sets (cc-pVDZ).63 The surrounding water was modeled using the polarizable solvation model (SMD).64 We considered several starting geometries of the H2O2···GA complexes and selected the most stable for further analysis. The interaction energies (Eint) between H2O2 and graphene derivatives were calculated as Eint = E(complex) – E(H2O2) – E(graphene derivative).
Acknowledgments
The authors gratefully acknowledge financial support from the University of Trieste (program FRA 2018 – project INSIDE), the Italian Ministry for University and Research (MIUR – program FFARB 2017), the INSTM consortium, the Ministry of Education, Youth and Sports of the Czech Republic (via projects CZ.1.05/2.1.00/19.0377, and CZ.02.1.01/0.0/0.0/16_019/0000754), and the Czech Science Foundation (project GA CR – EXPRO, 19-27454X). MO also acknowledges support by the ERC (Consolidator grant 683024 from the European Union’s Horizon 2020 research and innovation program). Martin Petr (XPS), Ondřej Tomanec (HR-TEM), Cecilia Maria Reyes Perez (SEM), Radka Pechancova (ICP) and Dr. David Milde (ICP) are acknowledged for the measurements.
Glossary
ABBREVIATIONS
- GA
graphene acid
- GCE
glassy carbon electrode
- ICP-MS
inductively coupled plasma mass spectrometry
- CNTs
carbon nanotubes
- G-CN
cyanographene
- EIS
electrochemical impedance spectroscopy
- SCE
saturated calomel electrode
- DFT
Density functional theory
- FG
fluorographene
- HR-XPS
high resolution X-ray photoelectron spectroscopy
- EDS
energy-dispersive X-ray spectroscopy
- HR-TEM
high resolution transmission electron microscopy
- HAADF-STEM
high angle annular dark field scanning transmission electron microscopy
- CV
cyclic voltammetry
- IR
infra-red
Supporting Information Available
The Supporting Information is available free of charge on the ACS Publications website at DOI: 10.1021/acsomega.9b02881.
Synthesis of cyanographene, EIS measurements, characterization methods, supplementary tables and figures (PDF)
Author Contributions
The manuscript was written through contributions of all authors. All authors have given approval to the final version of the manuscript.
The authors declare no competing financial interest.
Supplementary Material
References
- Chen W.; Cai S.; Ren Q.-Q.; Wen W.; Zhao Y.-D. Recent advances in electrochemical sensing for hydrogen peroxide: a review. Analyst 2012, 137, 49. 10.1039/C1AN15738H. [DOI] [PubMed] [Google Scholar]
- Myers R. L.The 100 most important chemical compounds: A reference guide; firsted. Greenwood Press: Westport, CT, 2007. [Google Scholar]
- Gülden M.; Jess A.; Kammann J.; Maser E.; Seibert H. Cytotoxic potency of H2O2 in cell cultures: impact of cell concentration and exposure time. Free Radical Biol. Med. 2010, 49, 1298–1305. 10.1016/j.freeradbiomed.2010.07.015. [DOI] [PubMed] [Google Scholar]
- Hydrogen Peroxide |Cosmetics Info, http://www.cosmeticsinfo.org/ingredient/hydrogen-peroxide-0, accessed: 7 May 2019.
- Nogueira R. F. P.; Oliveira M. C.; Paterlini W. C. Simple and fast spectrophotometric determination of H2O2 in photo-Fenton reactions using metavanadate. Talanta 2005, 66, 86–91. 10.1016/j.talanta.2004.10.001. [DOI] [PubMed] [Google Scholar]
- Yang Q.; Lu S.; Shen B.; Bao S.; Liu Y. An iron hydroxyl phosphate microoctahedron catalyst as an efficient peroxidase mimic for sensitive and colorimetric quantification of H2O2 and glucose. New J. Chem. 2018, 42, 6803. 10.1039/C8NJ00324F. [DOI] [Google Scholar]
- Peng H.; Lin D.; Liu P.; Wu Y.; Li S.; Lei Y.; Chen W.; Chen Y.; Lin X.; Xia X.; Liu A. Highly sensitive and rapid colorimetric sensing platform based on water-soluble WOx quantum dots with intrinsic peroxidase-like activity. Anal. Chim. Acta 2017, 992, 128. 10.1016/j.aca.2017.09.011. [DOI] [PubMed] [Google Scholar]
- Zhang D.; Mao X.; Zhang Z.; Zhang S.; Chen J.; Shan D.; Lu X. Fabricated nanoplatform of Cu(II)-functionalized mimetic-peroxidase with catalytic property toward sensitive monitoring of hydrogen peroxide. Sens. Actuators, B 2019, 284, 684. 10.1016/j.snb.2019.01.010. [DOI] [Google Scholar]
- Gomes A.; Fernandes E.; Lima J. L. Fluorescence probes used for detection of reactive oxygen species. J. Biochem. Biophys. Methods 2005, 65, 45. 10.1016/j.jbbm.2005.10.003. [DOI] [PubMed] [Google Scholar]
- Lee J. H.; Tang I. N.; Weinstein-Lloyd J. B. A non-enzymatic method for the determination of hydrogen peroxide in atmospheric samples. Anal. Chem. 1990, 62, 2381. 10.1021/ac00220a022. [DOI] [Google Scholar]
- Lu H.; Yu C.; Zhang Y.; Xu S. Efficient core shell structured dual response ratiometric fluorescence probe for determination of H2O2 and glucose via etching of silver nanoprisms. Anal. Chim. Acta 2019, 1048, 178. 10.1016/j.aca.2018.10.025. [DOI] [PubMed] [Google Scholar]
- Hanaoka S.; Lin J.-M.; Yamada M. Chemiluminescent flow sensor for H2O2 based on the decomposition of H2O2 catalyzed by cobalt(II)-ethanolamine complex immobilized on resin. Anal. Chim. Acta 2001, 426, 57. 10.1016/S0003-2670(00)01181-8. [DOI] [Google Scholar]
- Tang X. Q.; Zhang Y. D.; Jiang Z. W.; Wang D. M.; Huang C. Z.; Li Y. F. Fe3O4 and metal-organic framework MIL-101(Fe) composites catalyze luminol chemiluminescence for sensitively sensing hydrogen peroxide and glucose. Talanta 2018, 179, 43. 10.1016/j.talanta.2017.10.049. [DOI] [PubMed] [Google Scholar]
- Chen H.; Lin L.; Li H.; Li J.; Lin J.-M. Aggregation-induced structure transition of protein-stabilized zinc/copper nanoclusters for amplified chemiluminescence. ACS Nano 2015, 9, 2173. 10.1021/acsnano.5b00141. [DOI] [PubMed] [Google Scholar]
- Pan F.; Wei P.; Zhang M.; Lu C. Micelle modified-carbon nanosphere enhanced chemiluminescence from reactive oxygen species for the detection of hydrogen peroxide. Anal. Methods 2015, 7, 5667. 10.1039/C5AY01302J. [DOI] [Google Scholar]
- Li Y.; You X.; Shi X. Enhanced chemiluminescence determination of hydrogen peroxide in milk sample using metal–organic framework Fe–MIL–88NH2 as peroxidase mimetic. Food Anal. Methods 2017, 10, 626. 10.1007/s12161-016-0617-0. [DOI] [Google Scholar]
- Wang J. Electrochemical biosensors: towards point-of-care cancer diagnostics. Biosens. Bioelectron. 2006, 21, 1887. 10.1016/j.bios.2005.10.027. [DOI] [PubMed] [Google Scholar]
- Amarnath C. A.; Sawant S. N. Tailoring synthesis strategies for polyaniline-prussian blue composite in view of energy storage and H2O2 sensing application. Electrochim. Acta 2019, 295, 294. 10.1016/j.electacta.2018.10.132. [DOI] [Google Scholar]
- Ebrahimi A.; Zhang K.; Dong C.; Subramanian S.; Butler D.; Bolotsky A.; Goodnight L.; Cheng Y.; Robinson J. A. FeSx-graphene heterostructures: Nanofabrication-compatible catalysts for ultra-sensitive electrochemical detection of hydrogen peroxide. Sens. Actuators, B 2019, 285, 631. 10.1016/j.snb.2018.12.033. [DOI] [Google Scholar]
- Liu T.; Guo Y.; Zhang Z.; Miao Z.; Zhang X.; Su Z. Fabrication of hollow CuO/PANI hybrid nanofibers for non-enzymatic electrochemical detection of H2O2 and glucose. Sens. Actuators, B 2019, 286, 370. 10.1016/j.snb.2019.02.006. [DOI] [Google Scholar]
- Mao L.; Osborne P. G.; Yamamoto K.; Kato T. Continuous On-Line Measurement of Cerebral Hydrogen Peroxide Using Enzyme-Modified Ring-Disk Plastic Carbon Film Electrode. Anal. Chem. 2002, 74, 3684. 10.1021/ac011261+. [DOI] [PubMed] [Google Scholar]
- Breslow R. Biomimetic chemistry and artificial enzymes: catalysis by design. Acc. Chem. Res. 1995, 28, 146. 10.1021/ar00051a008. [DOI] [Google Scholar]
- Bracamonte M. V.; Melchionna M.; Giuliani A.; Nasi L.; Tavagnacco C.; Prato M.; Fornasiero P. H2O2 sensing enhancement by mutual integration of single walled carbon nanohorns with metal oxide catalysts: the CeO2 case. Sens. Actuators, B 2017, 239, 923. 10.1016/j.snb.2016.08.112. [DOI] [Google Scholar]
- McCreery R. L. Advanced carbon electrode materials for molecular electrochemistry. Chem. Rev. 2008, 108, 2646. 10.1021/cr068076m. [DOI] [PubMed] [Google Scholar]
- Duan X.; Xu J.; Wei Z.; Ma J.; Guo S.; Wang S.; Liu H.; Dou S. Metal-free carbon materials for CO2 electrochemical reduction. Adv. Mater. 2017, 29, 1701784. 10.1002/adma.201701784. [DOI] [PubMed] [Google Scholar]
- Gao Z.; Zhang Y.; Song N.; Li X. Biomass-derived renewable carbon materials for electrochemical energy storage. Mater. Res. Lett. 2017, 5, 69. 10.1080/21663831.2016.1250834. [DOI] [Google Scholar]
- Rachiy B. I.; Budzulyak I. M.; Vashchynsky V. M.; Ivanichok N. Y.; Nykoliuk M. O. Electrochemical properties of nanoporous carbon material in aqueous electrolytes. Nanoscale Res. Lett. 2016, 11, 18. 10.1186/s11671-016-1241-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Rivera L. M.; García G.; Pastor E. Novel graphene materials for the oxygen reduction reaction. Curr. Opin. Electrochem. 2018, 9, 233. 10.1016/j.coelec.2018.05.009. [DOI] [Google Scholar]
- Iglesias D.; Giuliani A.; Melchionna M.; Marchesan S.; Criado A.; Nasi L.; Bevilacqua M.; Tavagnacco C.; Vizza F.; Prato M.; Fornasiero P. N-doped graphitized carbon nanohorns as a forefront electrocatalyst in highly selective O2 reduction to H2O2. Chem 2018, 4, 106. 10.1016/j.chempr.2017.10.013. [DOI] [Google Scholar]
- Kim H. W.; Ross M. B.; Kornienko N.; Zhang L.; Guo J.; Yang P.; McCloskey B. D. Efficient hydrogen peroxide generation using reduced graphene oxide-based oxygen reduction electrocatalysts. Nat. Catal. 2018, 1, 282. 10.1038/s41929-018-0044-2. [DOI] [Google Scholar]
- Lu Z.; Chen G.; Siahrostami S.; Chen Z.; Liu K.; Xie J.; Liao L.; Wu T.; Lin D.; Liu Y.; Jaramillo T. F.; Nørskov J. K.; Cui Y. High-efficiency oxygen reduction to hydrogen peroxide catalysed by oxidized carbon materials. Nat. Catal. 2018, 1, 156. 10.1038/s41929-017-0017-x. [DOI] [Google Scholar]
- Banks C. E.; Davies T. J.; Wildgoose G. G.; Compton R. G. Electrocatalysis at graphite and carbon nanotube modified electrodes: edge-plane sites and tube ends are the reactive sites. Chem. Commun. 2005, 0, 829. 10.1039/B413177K. [DOI] [PubMed] [Google Scholar]
- Wu L.; Zhang X.; Ju H. Detection of NADH and ethanol based on catalytic activity of soluble carbon nanofiber with low overpotential. Anal. Chem. 2007, 79, 453. 10.1021/ac061282+. [DOI] [PubMed] [Google Scholar]
- Zhou M.; Guo J.; Guo L.-p.; Bai J. Electrochemical sensing platform based on the highly ordered mesoporous carbon–fullerene system. Anal. Chem. 2008, 80, 4642. 10.1021/ac702496k. [DOI] [PubMed] [Google Scholar]
- Rabti A.; Raouafi N.; Merkoçi A. Bio(sensing) devices based on ferrocene–functionalized graphene and carbon nanotubes. Carbon 2016, 108, 481. 10.1016/j.carbon.2016.07.043. [DOI] [Google Scholar]
- Wang J.; Musameh M.; Lin Y. Solubilization of carbon nanotubes by nafion toward the preparation of amperometric biosensors. J. Am. Chem. Soc. 2003, 125, 2408. 10.1021/ja028951v. [DOI] [PubMed] [Google Scholar]
- Wang J.; Musameh M. Carbon nanotube/teflon composite electrochemical sensors and biosensors. Anal. Chem. 2003, 75, 2075. 10.1021/ac030007+. [DOI] [PubMed] [Google Scholar]
- Pumera M.; Merkoçi A.; Alegret S. Carbon nanotube-epoxy composites for electrochemical sensing. Sens. Actuators, B 2006, 113, 617. 10.1016/j.snb.2005.07.010. [DOI] [Google Scholar]
- Wang J.; Yang S.; Guo D.; Yu P.; Li D.; Ye J.; Mao L. Comparative studies on electrochemical activity of graphene nanosheets and carbon nanotubes. Electrochem. Commun. 2009, 11, 1892. 10.1016/j.elecom.2009.08.019. [DOI] [Google Scholar]
- Takahashi S.; Abiko N.; Anzai J.-I. Redox response of reduced graphene oxide-modified glassy carbon electrodes to hydrogen peroxide and hydrazine. Materials 2013, 6, 1840. 10.3390/ma6051840. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zhou M.; Zhai Y.; Dong S. Electrochemical sensing and biosensing platform based on chemically reduced graphene oxide. Anal. Chem. 2009, 81, 5603. 10.1021/ac900136z. [DOI] [PubMed] [Google Scholar]
- Fan L.; Zhang Q.; Wang K.; Li F.; Niu L. Ferrocene functionalized graphene: preparation, characterization and efficient electron transfer toward sensors of H2O2. J. Mater. Chem. 2012, 22, 6165. 10.1039/c2jm15411k. [DOI] [Google Scholar]
- Zhang R.; Chen W. Recent advances in graphene-based nanomaterials for fabricating electrochemical hydrogen peroxide sensors. Biosens. Bioelectron. 2017, 89, 249. 10.1016/j.bios.2016.01.080. [DOI] [PubMed] [Google Scholar]
- Hamilton C. E.; Lomeda J. R.; Sun Z.; Tour J. M.; Barron A. R. High-yield organic dispersions of unfunctionalized graphene. Nano Lett. 2009, 9, 3460. 10.1021/nl9016623. [DOI] [PubMed] [Google Scholar]
- Liang Y.; Wu D.; Feng X.; Müllen K. Dispersion of graphene sheets in organic solvent supported by ionic interactions. Adv. Mater. 2009, 21, 1679. 10.1002/adma.200803160. [DOI] [Google Scholar]
- Woo S.; Kim Y.-R.; Chung T. D.; Piao Y.; Kim H. Synthesis of a graphene–carbon nanotube composite and its electrochemical sensing of hydrogen peroxide. Electrochim. Acta 2012, 59, 509. 10.1016/j.electacta.2011.11.012. [DOI] [Google Scholar]
- Wang Q.; Li M.; Szunerits S.; Boukherroub R. Environmentally friendly reduction of graphene oxide using tyrosine for nonenzymatic amperometric H2O2 detection. Electroanalysis 2014, 26, 156. 10.1002/elan.201300356. [DOI] [Google Scholar]
- Yeh M.-H.; Li Y.-S.; Chen G.-L.; Lin L.-Y.; Li T.-J.; Chuang H.-M.; Hsieh C.-Y.; Lo S.-C.; Chiang W.-H.; Ho K.-C. Facile synthesis of boron-doped graphene nanosheets with hierarchical microstructure at atmosphere pressure for metal-free electrochemical detection of hydrogen peroxide. Electrochim. Acta 2015, 172, 52. 10.1016/j.electacta.2015.01.210. [DOI] [Google Scholar]
- Eng A. Y. S.; Chua C. K.; Pumera M. Refinements to the structure of graphite oxide: absolute quantification of functional groups via selective labelling. Nanoscale 2015, 7, 20256. 10.1039/C5NR05891K. [DOI] [PubMed] [Google Scholar]
- Liao L.; Peng H.; Liu Z. Chemistry makes graphene beyond graphene. J. Am. Chem. Soc. 2014, 136, 12194. 10.1021/ja5048297. [DOI] [PubMed] [Google Scholar]
- Park J.; Yan M. Covalent functionalization of graphene with reactive intermediates. Acc. Chem. Res. 2013, 46, 181. 10.1021/ar300172h. [DOI] [PubMed] [Google Scholar]
- Poulos T. L.; Kraut J. The stereochemistry of peroxidase catalysis. J. Biol. Chem. 1980, 255, 8199. [PubMed] [Google Scholar]
- Bakandritsos A.; Pykal M.; Błoński P.; Jakubec P.; Chronopoulos D. D.; Poláková K.; Georgakilas V.; Čépe K.; Tomanec O.; Ranc V.; Bourlinos A. B.; Zbořil R.; Otyepka M. Cyanographene and graphene acid: emerging derivatives enabling high-Yield and selective functionalization of graphene. ACS Nano 2017, 11, 2982. 10.1021/acsnano.6b08449. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Radhakrishnana S.; Kim S. J. An enzymatic biosensor for hydrogen peroxide based on one-pot preparation of CeO2-reduced graphene oxide nanocomposite. RSC Adv. 2015, 5, 12937. 10.1039/C4RA12841A. [DOI] [Google Scholar]
- Mayo D. W. in Course Notes on the interpretation of infrared and raman spectra; Mayo D. W.; Miller F. A.; Hannah R. W. Ed., John Wiley & Sons: Hoboken, New Jersey: 2003; pp. 101–140. [Google Scholar]
- Szabó T.; Berkesi O.; Forgó P.; Josepovits K.; Sanakis Y.; Petridis D.; Dékány I. Evolution of surface functional groups in a series of progressively oxidized graphite oxides. Chem. Mater. 2006, 18, 2740. 10.1021/cm060258+. [DOI] [Google Scholar]
- Jha S. K.; Vasiliev I. Vibrational signatures of carboxylated graphene: a first-principles study. J. Phys. Chem. C 2018, 122, 24996. 10.1021/acs.jpcc.8b06274. [DOI] [Google Scholar]
- Eda G.; Fanchini G.; Chhowalla M. Large-area ultrathin films of reduced graphene oxide as a transparent and flexible electronic material. Nat. Nanotechnol. 2008, 3, 270. 10.1038/nnano.2008.83. [DOI] [PubMed] [Google Scholar]
- Gupta B.; Kumar N.; Panda K.; Kanan V.; Joshi S.; Visoly-Fisher I. Role of oxygen functional groups in reduced graphene oxide for lubrication. Sci. Rep. 2017, 7, 45030. 10.1038/srep45030. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chen X.; Wu G.; Cai Z.; Oyama M.; Chen X. Advances in enzyme-free electrochemical sensors for hydrogen peroxide, glucose, and uric acid. Microchim. Acta 2014, 181, 689. 10.1007/s00604-013-1098-0. [DOI] [Google Scholar]
- Cheong Y. H.; Nasir M. Z. M.; Bakandritsos A.; Pykal M.; Jakubec P.; Zbořil R.; Otyepka M.; Pumera M. Cyanographene and graphene acid: the functional group of graphene derivative determines the application in electrochemical sensing and capacitors. ChemElectroChem 2019, 6, 229. 10.1002/celc.201800675. [DOI] [Google Scholar]
- Chai J.-D.; Head-Gordon M. Long-range corrected hybrid density functionals with damped atom–atom dispersion corrections. Phys. Chem. Chem. Phys. 2008, 10, 6615. 10.1039/b810189b. [DOI] [PubMed] [Google Scholar]
- Dunning T. H. Jr. Gaussian basis sets for use in correlated molecular calculations. I. The atoms boron through neon and hydrogen. J. Chem. Phys. 1989, 90, 1007. 10.1063/1.456153. [DOI] [Google Scholar]
- Marenich A. V.; Cramer C. J.; Truhlar D. G. Universal solvation model based on solute electron density and on a continuum model of the solvent defined by the bulk dielectric constant and atomic surface tensions. J. Phys. Chem. B 2009, 113, 6378. 10.1021/jp810292n. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.