Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2019 Nov 29;9:17922. doi: 10.1038/s41598-019-54380-y

Paper-Based SERS Platform for One-Step Screening of Tetracycline in Milk

Ana Marques 1,#, Bruno Veigas 1,2,#, Andreia Araújo 1,3, Beatriz Pagará 1, Pedro Viana Baptista 2, Hugo Águas 1, Rodrigo Martins 1, Elvira Fortunato 1,
PMCID: PMC6884497  PMID: 31784619

Abstract

Throughout the last decade, the expansion of food testing has been gradually moving towards ordinary high throughput screening methods performed on-site. The demand for point-of-care testing, able to distinguish molecular signatures with high accuracy, sensitivity and specificity has been significantly increasing. This new requirement relies on the on-site detection and monitorization of molecular signatures suitable for the surveillance of food production and processing. The widespread use of antibiotics has contributed to disease control of livestock but has also created problems for the dairy industry and consumers. Its therapeutic and subtherapeutic use has increased the risk of contamination in milk in enough concentrations to cause economic losses to the dairy industry and have a health impact in highly sensitive individuals. This study focuses on the development of a simple Surface-Enhanced Raman Spectroscopy (SERS) method for fast high throughput screening of tetracycline (TET) in milk. For this, we integrate a paper-based low-cost, fully recyclable and highly stable SERS platform, with a minimal sample preparation protocol. A two-microliter sample of milk solutions spiked with TET (from 0.01 to 1000 ppm) is dried on a silver nanoparticle coated cardboard substrate and measured via a Raman spectrophotometer. The SERS substrate showed to be extremely stable with a shelf life of several months. A global spectrum principal component analysis approach was used to test all the detected vibrational modes and their correlation with TET concentration. Peak intensity ratios (455 cm−1/1280 cm−1 and 874 cm−1/1397 cm−1) were found to be correlated with TET concentrations in milk, achieving a sensitivity as low as 0.1 ppm. Results indicate that this SERS method combined with portable Raman spectrometer is a potential tool that can be used on-site for the monitoring of TET residues and other antibiotics.

Subject terms: Assay systems, Chemistry, Nanoscience and technology

Introduction

Nowadays, antibiotics are extensively used not only for the control of diseases but also for nutritional purposes of livestock. However, it’s massive use has created problems for the milk transformation industry and consumers1,2. The residues of antibiotics in milk can cause several problems to the final consumer such as, allergic reactions and development of antibiotic-resistance microorganisms, as well as being responsible for the disruption of Ca2+ metabolism which is harmful to the formation of teeth and bones in children. Less common effects are induced photosensitivity and increased hypersensitivity to light15. When antibiotics are used, dairymen should follow specific protocols to prevent the prevalence of antibiotic residues in human milk. Despite that, reports show that there is still presence of antibiotics in milk, above the recommended values1,6. Their relative stability to the pasteurization processes and the high quantities of milk required to dilute milk from treated quarters, can cause monetary losses and technological problems to the dairy industry. So, the use of monitoring tests by regulatory authorities and the dairy personnel have shown to drastically decrease the occurrence of antibiotic-adulterated milk1,2. Nowadays, the most common methods employed for antibiotics residues monitoring include microbial inhibition tests7,8, immunoassays9,10, and chemical-physical methods such as high-performance liquid chromatography11,12 or mass spectroscopy13,14. However, these methods have high operational costs, complex sample preparation, normally require a high quantity of reagents volume and specialized personnel and the samples analyzed per time unit are few2,6.

Nanoscale enabled technologies have been revolutionizing the routine laboratory detection schemes. These platforms may substitute the standard approaches used in molecular detection and characterization at centralized facilities. The main impact of this technology focus on miniaturization and increased sensitivity, allowing for low sample volume and decreased analysis time15,16. From these technologies, SERS has been gaining some attraction, since it can enhance Raman signals up to 14 orders of magnitude1719. Recent advances in nanoscience catalyzed an explosion of possibilities regarding nanostructured substrates design and fabrication15,16,2023. The development of improved SERS substrates together with portable Raman spectrometers is allowing this technique to spread into the point-of-need molecular detection and characterization scene6,20. One of the benefits of SERS is that it allows analyte’s detection without the need for any sample prep, with a high sensitivity.

The performance of the SERS technique depends on the choice of materials and nanostructures of the SERS-active substrate15,19,20. Recently, cellulose based substrates have been developed for several opto-electronic applications due to its unique set of advantages (e.g. 100% recyclable, flexible and low-cost)21,2426. These exciting applications of paper-based materials for bio-detection, are today presenting several advantages over conventional substrates, due to their inexpensive and easy-to-process nature, achieving high Raman signal enhancements (EF ≈ 105–107) comparable with the commercial counterparts16,27. However, the adaptation of these substrates to large scale production is still difficult and complex, especially in the validation, reproducibility and standardization factors21,28. Once these issues are solved, it is expected that these platforms will expand from the conceptual demonstrations to real products.

Currently, the most common methods to fabricate these substrates have critical obstacles such as time-consuming complex patterning processes associated with high costs, which limits its extensive use in macroscopic scale systems15,20,26. Metal deposition by e-beam evaporation results in the direct arrangement of individual nanoparticles (NPs), with a good control of size and shape, without the need for any thermal treatment21,29. This one-step approach consists on the formation of Ag NPs in situ during the thermal evaporation of thin films of Ag deposited on substrates that are heated up to 150 °C21. This considerable low temperature is applicable to a broad range of low-cost and flexible substrate materials, that are not compatible with the conventional annealing de-wetting methods carried out at higher temperatures (300–500 °C)21,3032. This process allows for a simple and inexpensive production of SERS substrates that are highly stable, homogeneous in terms of morphology and exhibit prominent Raman enhancement effects throughout the substrate21.

This work reports on highly efficient SERS platforms based on the AgNPs combined with an inexpensive, recyclable and widely used cardboard substrate, commonly used as disposable packaging material, previously fully described in a previous work from our group21.

In this work, we show the proof-of-concept of using this nanoplasmonic platform for the analysis of antibiotic residues in milk, demonstrating that this one-step thermal evaporation production method combined with an statistical analysis is able to exhibit a very strong SERS signal, with notable stability and shelf-life. This approach allows for a single-step detection and quantification of TET in milk without the need for any sample’s pre-treatment.

Results and Discussion

Substrate production and characterization

SERS substrates were produced on cardboard packaging by thermal deposition of a 6 nm Ag film. The cardboard is composed by a paper-based layer coated with evaporated aluminum. In contact with air, a thin layer of AlxOy is formed which is essential for the growth of metallic NPs by the solid-state dewetting method. An optimization of SERS response to the Ag NPs of various shapes and sizes was systematically investigated elsewhere, in a previous work of some of the authors21. A electromagnetic simulation using the Mie theory was performed and helped determine that 6 nm Ag thin film, that renders 60 nm-sized Ag NPs gives the best SERS substrate for molecular detection21. This optimal local electric field enhancement is able to increase the Raman signal up to 10621. To calculate this enhancement factor, it was used the area under the rhodamine 6G spectra’s peak at 1360 cm−1 of the SERS platform and of the cardboard without the AgNPs. This factor was calculated according to the literature21 using the expression ISERS × CSERS/IRaman × CRaman, where ISERS and CSERS is the area under the 1360 cm−1 peak and the concentration of rhodamine (10−6 M), respectively in the SERS platform and, IRaman and CRaman is obtained from the cardboard substrate, where CRaman is 10−3 M. Reproducibility and stability analysis of the produced substrates was also assessed showing an intensity variation lower than 5% along the substrate area, with a shelf life higher than 6 months without loss in SERS performance21,33. This high shelf life is due to the lower oxidation of the Ag NPs in the presence of the aluminum layer in the cardboard structure. This metal layer acts as a sacrificial layer, providing anodic protection and preventing possible oxidation of the NPs. This is due to the higher standard reduction electrode potential of silver in comparison with aluminum – silver has a higher tendency to reduce and aluminum to oxidize21.

Scanning electron microscopy and atomic force microscopy analyses of the cardboard substrates after the NPs deposition have been carried out (Fig. 1).

Figure 1.

Figure 1

Production and characterization of cardboard-Ag NPs SERS substrates. (a) Optical photograph of the Ag NPs-cardboard platform with milk spiked TET measurement set up. The zoom in represents a schematic representation of a single measurement. (b) SEM image of the Ag NPs on top of the cardboard substrate. The histogram for the size particle distribution is presented in the inset image. (c) AFM image showing the cardboard substrate with Ag NPs.

The SEM image of the produced Ag NPs (Fig. 1b), on top of the cardboard substrate, reveals a highly dense and uniform distribution of the nanostructures with an elongated spherical shape and an average diameter of 60 nm, as showed in the histogram. The uniformity and close proximity of the nanostructures, produced by thermal evaporation, contributes to the high reproducibility of SERS and to the Raman signal enhancement, due to the presence of hot spots (narrow gaps between neighbors NPs), that are excited by the surface plasmon coupling34. Additionally, AFM measurements of the NPs revealed an average height of ~46 nm, with typical in-plane ellipsoid axes ratios of ~1.3 (Fig. 1c).

Implementation of plasmonic cardboard substrate as SERS device

To test the ability of reproducible detection and quantification of TET with this platform, SERS spectra of whole milk with added calibrated concentrations of TET were acquired. A two-microliter sample was deposited onto the SERS substrate and allowed to dry, after which four individual spectra were measured for each concentration. The measured SERS spectra of milk with and without TET (500 ppm) are shown in Fig. 2a. The SERS spectra of a few representative tested TET concentrations is presented in Supplementary Fig. S1.

Figure 2.

Figure 2

Raman spectra of TET spiked milk analysis (n = 3). (a) Raman spectra of milk (bottom) and 500 ppm TET spiked milk (top) showing its characteristic peaks. (b) Principal component analysis of TET detection and quantification in cardboard SERS substrate. The two eigenvectors F1 & F2 accounting for 96.12% of total variance in the data set. (c) Correlation between the eigenvector F2 variance and TET concentration. Each point corresponds to the mean value and error bars to the standard deviation of three independent measurements. A linear correlation (R2 = 0.9153) between the variance of the vector F2 and TET concentration is observed within the desired range (0–10 ppm).

Figure 2a shows the SERS spectra of milk and milk spiked with 500 ppm of TET. The characteristic peaks of milk and TET were only visible when the enhancement effect of the Ag colloid nanoparticles was used. The SERS spectra of TET in aqueous solution was recorded and is presented in Supplementary Fig. S2, showing TET characteristic Raman shifts. Additionally, to the characteristic milk peaks in Fig. 2a, a set of more pronounced peaks appear in the TET spiked milk at 1280 cm−1, 1322 cm−1 and 1621 cm−1. This evidence is in accordance with the TET characteristic peaks reported in the literature6,35 although with a small shift, due to the interaction of the TET with the milk matrix. The peak at 1280 cm−1 is correlated to bending modes of C-H in the positions 4, 4a, 5, 5a, O-H12 and amid-NH and to stretching modes of C10, 3-O, C-H7, 8, 9, C4a-C5 and amid-NC. The peak at 1322 cm−1 is assigned to ring breathing of stretching modes C6a-C7, C9-C10 and bending modes of O-H10, 12 and also to C-H4, 4a, 5, 5a. Finally, the peak at 1621 cm−1 is attributed to the stretching modes of C1,3-O, C2-C3 and amid-CO and to the breathing modes of amid-CO and amid-NH.

A principal component analysis (PCA) was performed to all the characteristic peaks (Fig. 2b), obtained in triplicates. The PCA showed that 96% of the variance was comprised in two eigenvectors. Most of the variance (80%) in all the analyzed characteristic peaks only showed a correlation to TET concentrations above 100 ppm. However, the second eigenvector corresponding to 16.1% of total variance showed a good correlation (R2 = 0.9153) for lower concentration of (<100 ppm) (Fig. 2c). While PCA is extremely powerful to access the correlation between spectral changes and analyte concentrations we envisioned a simplified measurement procedure that reduced the acquisition time while allowing to acquire more data points, thus circumventing one of the drawbacks of SERS-based detection approach (ensure sample representativeness).

Previous reports have used these characteristic peaks and peak ratios for the quantification of antibiotics in whole milk6. However, the PCA analysis showed that for lower analyte concentrations most of these peaks (present in the eigenvector F1 and representing 80% of the total variance) may not be the most appropriate approach for low quantification concentration window (see Supplementary Fig. S3). As such, in this approach, we analyzed all the possible combinations of peak ratios and their correlation to the concentration of the analyte (see Supplementary Fig. S4).

The characteristic milk peaks used in the showed ratios, at 455 cm−1, 1397 cm−1 and 1669 cm−1, although with small shifts, can be attribute to lactose, amino acids (such as glycine and l-valine) and to amide I, respectively36,37. The disappearance of the 1397 cm−1 peak in the milk/TET spectrum it is possibly due to the interaction of TET with the protein fraction of milk. Evidence of this interaction has been previously shown elsewhere, where it is described the adsorption capability of TET to milk38. From all peak and peak ratio intensities present in the full spectra the ratio 455 cm−1/1280 cm−1 (Fig. 3a) showed a linear correlation in a logarithmic scale (R2 = 0.97) for the entire tested range (0–1000 ppm). For this ratio, the limit of detection (LOD) was found to be 0.1 ppm. Another two peak combinations showed high correlation to analyte concentration (1320 cm−1/1669 cm−1 and 874 cm−1/1397 cm−1). The ratio 1320 cm−1/1669 cm−1 (Fig. 3b) is a clear representation of the correlation found in the PCA F1 vector analysis, with an LOD above 100 ppm of TET, well above the desired sensitivity needed for this application. Moreover, the ratio 874 cm−1/1397 cm−1 showed to have a LOD lower than 0.01 ppm of TET (Fig. 3c). The present work follows a label-free approach for the simple detection and quantification of TET residues in milk with high-throughput, with a LOD within the maximum value defined by government associations. The SERS platform here employed presents an EF within the state-of-the-art and it is comparable with other works for the detection of residues in food with a label-free approach39. Although some reports, based on SERS40 or fluorescence-based methods41 report lower LOD for the detection of TET, they comprise complex procedures for the fabrication of the sensing platforms. Nonetheless, even having a higher LOD our SERS platform and detection method is able to answer to the maximum value of TET residues in milk, as defined by the United States Food and Drug Administration42 (0.3 ppm) and by the European Union43 (0.1 ppm). Additionally, these results prove that a simple two peak measurement approach is reliable for the practical detection of TET residue in milk. Also, the use of peak ratios allows for a faster measurement protocol making it possible to sample up to 100 times more spots within the sample while maintaining a low measurement time.

Figure 3.

Figure 3

Dependence of SERS signal intensity ratio and TET concentration (n = 3). (a) Correlation between ratio 455 cm−1/1280 cm−1 versus analyte concentration in logarithmic scale. Linear correlation y = −0.124ln(x) + 1.0154; R2 = 0.9738). (b) Correlation between ratio 1320 cm−1/1669 cm−1 versus analyte concentration in logarithmic scale. (c) Correlation between ratio 874 cm−1/1397 cm−1 versus analyte concentration in logarithmic scale. Diamond marker shows the ratio values obtained for milk samples without TET and grey shade the error (standard deviation). Each point in the final calibration curve corresponded to the mean value and the error bars to the standard deviation of three independent measurements.

Conclusions

Since the first conceptual demonstration of SERS for food analysis, several reports have been published with several types of analytes. Herein we demonstrate the use of a new platform, with a highly simplified sample handling and data analysis protocol. We believe that this conceptual assay represents a valuable alternative to currently used methodologies for identification and quantification of analytes. Furthermore, high reproducibility and stability of this SERS substrate was also demonstrated. The reported high tunability of surface plasmon resonance combined with the stable and reproducible nature of these substrates demonstrate their effectiveness to be applied in large area substrate for SERS.

All characteristic vibrational modes of milk and TET spiked milk, obtained in triplicate, were analyzed via a global PCA-based analysis allowing to develop a peak ratio approach for the detection and quantification of tetracycline without any sample pretreatment. The simplification of the detection protocol allows for a higher number of measurements within the same sample to have a better statistical representation and correlation of the spectral data to the target analyte concentration. This approach showed a sensitivity bellow 0.1 ppm, which is the maximum residue limit set by the governmental authorities. These results serve as a foundation to further explore this method for other analytes and samples types. The development of stable SERS substrates together with the portable Raman spectrophotometers might radically change the way we perform analyte detection and quantification at point-of-need.

Methods

Preparation and characterization of SERS platform

Tetracycline hydrochloride (TET) and tetraethylrhodamine hydrochloride (rhodamine 6G) were purchased from Sigma-Aldrich and used as received without further purification. Distilled water was passed through a Millipore water system (ρ = 18.2 MΩ), which was used in all of the experiments. Commercially obtained ultra-high-temperature processing (UHT) semi-skimmed milk, from a Portuguese brand “Mimosa” was used through all the experiments. The cardboard substrate, with a thickness of 0.4 mm, was supplied by StoraEnso (Helsinki, Finland) and silver metal pieces with 99,99% purity, supplied by CERAC, Inc. (Milwaukee, Wisconsin, USA), where used for AgNPs production.

The SERS platform production protocol is fully described and characterized elsewhere21. The cardboard packaging substrates used in this study is composed by, pressed cellulose fibers, polymeric coatings and evaporated aluminum, with a thin native oxide (AlxOy) layer present on top of the aluminum layer. Ag NPs were obtained by the deposition of metal layers directly on the cardboard substrate (10 × 10 cm2) using an electron gun-assisted thermal evaporation technique, while the substrate was kept at 150 °C during the thermal evaporation. The deposition was carried out with a working pressure of 10−5 mbar and a deposition rate of 0.07 nm s−1 until the thickness of the Ag film reached 6 nm. The thicknesses and growth rates of the films were inferred by a calibrated quartz crystal detector.

The cardboard substrate surface after the NPs deposition was imaged by scanning electron microscopy with a Carl Zeiss AURIGA CrossBeam (FIB-SEM) workstation. The average height of the NPs was measured with an Asylum MFP3D atomic force microscope (AFM) in ac mode.

SERS measurements and statistical analysis

Tetracycline was chosen as a model analyte to investigate the performance of the AgNPs-coated cardboard substrate for SERS detection in complex matrixes. The SERS substrates were prepared by dropping 2 μl of whole milk with added concentrations of TET with concentrations ranging from 0.01 to 1000 ppm onto the substrate. Samples were allowed to dry at room temperature (Fig. 1a).

Raman measurements were carried out with a Renishaw® inVia™ Qontor® confocal Raman microscope equipped with a Renishaw Centrus 2957T3 detector and a 633 nm laser operating at 50 mW. The spectra were recorded as an extended scan. The laser beam was focused with a 50× Olympus objective lens. All of the measurements were made with five scans of 10 s laser exposure. The 521 cm−1 peak of a silicon wafer was used between the different Raman sessions to calibrate the spectrograph for possible fluctuations of the Raman system.

Data is expressed as mean ± standard deviation from at least three independent experiments. Statistical analysis was performed using GraphPad Prism version 6.00 software. Principal Component Analysis was performed using XLStats 2014 software, to highlight the similarities and differences in the data. An orthogonal transformation was performed to convert a set of observations of possibly correlated variables into a set of values of linearly uncorrelated variables (principal components).

Supplementary information

Supplementary Information (514.1KB, pdf)
Dataset 1 (5.3MB, xlsx)

Acknowledgements

The authors acknowledge funding from project PTDC/CTM-NAN/2912/2014, PTDC/AAG-TEC/5400/2014, POCI-01-0145-FEDER-016637 and POCI-01-0145-FEDER-007688, UID/CTM/50025/2019 and UID/Multi/04378/2013 funded by European funds, through FEDER (European Funding or Regional Development) via COMPETE2020 – POCI (operational program for internationalization and competitively), by national funding through the National Foundation for Science and Technology, I.P. (FCT-MCTES). Ana Marques and Bruno Veigas were supported by FCT/MCTES (SFRH/BD/115173/2016 and SFRH/BPD/124311/2016, respectively).

Author contributions

A.M. and B.V. did the experimental work and wrote the manuscript; A.A. developed and produced the SERS platform; B.P. assisted in the experimental work; P.V.B., H.A., R.M. and E.F. supervised the work and reviewed the manuscript.

Data availability

The dataset related with this manuscript is available on a separated excel file.

Competing interests

The authors declare no competing interests.

Footnotes

Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

These authors contributed equally: Ana Marques and Bruno Veigas.

Supplementary information

is available for this paper at 10.1038/s41598-019-54380-y.

References

  • 1.Gajda A, Nowacka-Kozak E, Gbylik-Sikorska M, Posyniak A. Tetracycline antibiotics transfer from contaminated milk to dairy products and the effect of the skimming step and pasteurisation process on residue concentrations. Food Addit. Contam. - Part A Chem. Anal. Control. Expo. Risk Assess. 2018;35:66–76. doi: 10.1080/19440049.2017.1397773. [DOI] [PubMed] [Google Scholar]
  • 2.Sivakesava S, Irudayaraj J. Rapid Determination of Tetracycline in Milk by FT-MIR and FT-NIR Spectroscopy. J. Dairy Sci. 2002;85:487–493. doi: 10.3168/jds.S0022-0302(02)74099-X. [DOI] [PubMed] [Google Scholar]
  • 3.Chen Y, et al. High sensitive detection of penicillin G residues in milk by surface-enhanced Raman scattering. Talanta. 2017;167:236–241. doi: 10.1016/j.talanta.2017.02.022. [DOI] [PubMed] [Google Scholar]
  • 4.Piper T, et al. Determination of 13C/12C ratios of endogenous urinary steroids: methd validation, reference population and application to doping control purposes. Rapid Commun. Mass Spectrom. 2008;22:2161–2175. doi: 10.1002/rcm.3601. [DOI] [PubMed] [Google Scholar]
  • 5.Borghi AA, Palma MSA. Tetracycline: Production, waste treatment and environmental impact assessment. Brazilian J. Pharm. Sci. 2014;50:25–40. doi: 10.1590/S1984-82502011000100003. [DOI] [Google Scholar]
  • 6.Dhakal Sagar, Chao Kuanglin, Huang Qing, Kim Moon, Schmidt Walter, Qin Jianwei, Broadhurst C. A Simple Surface-Enhanced Raman Spectroscopic Method for on-Site Screening of Tetracycline Residue in Whole Milk. Sensors. 2018;18(2):424. doi: 10.3390/s18020424. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Kurittu J, Lonberg S, Virta M, Karp M. Qualitative Detection of Tetracycline Residues in Milk with a Luminescence-Based Microbial Method: The Effect of Milk Composition and Assay Performance in Relation to an Immunoassay and a Microbial Inhibition Assay. J. Food Prot. 2000;63:953–957. doi: 10.4315/0362-028X-63.7.953. [DOI] [PubMed] [Google Scholar]
  • 8.Pikkemaat MG, Dijk SO, Schouten J, Rapallini M, van Egmond HJ. A new microbial screening method for the detection of antimicrobial residues in slaughter animals: The Nouws antibiotic test (NAT-screening) Food Control. 2008;19:781–789. doi: 10.1016/j.foodcont.2007.08.002. [DOI] [Google Scholar]
  • 9.Zhou L, Li D-J, Gai L, Wang J-P, Li Y-B. Electrochemical aptasensor for the detection of tetracycline with multi-walled carbon nanotubes amplification. Sensors Actuators B Chem. 2012;162:201–208. doi: 10.1016/j.snb.2011.12.067. [DOI] [Google Scholar]
  • 10.Luo Y, et al. A novel colorimetric aptasensor using cysteamine-stabilized gold nanoparticles as probe for rapid and specific detection of tetracycline in raw milk. Food Control. 2015;54:7–15. doi: 10.1016/j.foodcont.2015.01.005. [DOI] [Google Scholar]
  • 11.Cinquina AL, Longo F, Anastasi G, Giannetti L, Cozzani R. Validation of a high-performance liquid chromatography method for the determination of oxytetracycline, tetracycline, chlortetracycline and doxycycline in bovine milk and muscle. J. Chromatogr. A. 2003;987:227–233. doi: 10.1016/S0021-9673(02)01446-2. [DOI] [PubMed] [Google Scholar]
  • 12.Fritz JW, Zuo Y. Simultaneous determination of tetracycline, oxytetracycline, and 4-epitetracycline in milk by high-performance liquid chromatography. Food Chem. 2007;105:1297–1301. doi: 10.1016/j.foodchem.2007.03.047. [DOI] [Google Scholar]
  • 13.Andersen WC, et al. Determination of tetracycline residues in shrimp and whole milk using liquid chromatography with ultraviolet detection and residue confirmation by mass spectrometry. Anal. Chim. Acta. 2005;529:145–150. doi: 10.1016/j.aca.2004.08.012. [DOI] [PubMed] [Google Scholar]
  • 14.Blasco C, Corcia AD, Picó Y. Determination of tetracyclines in multi-specie animal tissues by pressurized liquid extraction and liquid chromatography–tandem mass spectrometry. Food Chem. 2009;116:1005–1012. doi: 10.1016/j.foodchem.2009.03.055. [DOI] [Google Scholar]
  • 15.Fan M, Andrade GFS, Brolo AG. A review on the fabrication of substrates for surface enhanced Raman spectroscopy and their applications in analytical chemistry. Anal. Chim. Acta. 2011;693:7–25. doi: 10.1016/j.aca.2011.03.002. [DOI] [PubMed] [Google Scholar]
  • 16.Tripp RA, Dluhy RA, Zhao Y. Novel nanostructures for SERS biosensing. Nano Today. 2008;3:31–37. doi: 10.1016/S1748-0132(08)70042-2. [DOI] [Google Scholar]
  • 17.Kumar S, Goel P, Singh JP. Flexible and robust SERS active substrates for conformal rapid detection of pesticide residues from fruits. Sensors Actuators, B Chem. 2017;241:577–583. doi: 10.1016/j.snb.2016.10.106. [DOI] [Google Scholar]
  • 18.Schwartzberg AM, Zhang JZ. Surface-Enhanced Raman Scattering (SERS) Nanotechnology. 2006;27:16–18. [Google Scholar]
  • 19.Gómez M, Lazzari M. Reliable and cheap SERS active substrates: Ordered vs disordered. Mater. Today. 2014;17:358–359. doi: 10.1016/j.mattod.2014.08.001. [DOI] [Google Scholar]
  • 20.Sharma B, Frontiera RR, Henry AI, Ringe E, Van Duyne RP. SERS: Materials, applications, and the future. Mater. Today. 2012;15:16–25. doi: 10.1016/S1369-7021(12)70017-2. [DOI] [Google Scholar]
  • 21.Araújo A, et al. Highly efficient nanoplasmonic SERS on cardboard packaging substrates. Nanotechnology. 2014;25:415202. doi: 10.1088/0957-4484/25/41/415202. [DOI] [PubMed] [Google Scholar]
  • 22.Zhang Y, Zhao S, Zheng J, He L. Surface-enhanced Raman spectroscopy (SERS) combined techniques for high-performance detection and characterization. TrAC - Trends Anal. Chem. 2017;90:1–13. doi: 10.1016/j.trac.2017.02.006. [DOI] [Google Scholar]
  • 23.Sharma B, et al. High-performance SERS substrates: Advances and challenges. MRS Bull. 2013;38:615–624. doi: 10.1557/mrs.2013.161. [DOI] [Google Scholar]
  • 24.Vicente António T., Araújo Andreia, Gaspar Diana, Santos Lídia, Marques Ana C., Mendes Manuel J., Pereira Luís, Fortunato Elvira, Martins Rodrigo. Nanostructured Solar Cells. 2017. Optoelectronics and Bio Devices on Paper Powered by Solar Cells. [Google Scholar]
  • 25.Marques AC, et al. Office Paper Platform for Bioelectrochromic Detection of Electrochemically Active Bacteria using Tungstens Oxide Nanoprobes. Sci. Rep. 2015;5:1–7. doi: 10.1038/srep09910. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Costa MN, et al. A low cost, safe, disposable, rapid and self-sustainable paper-based platform for diagnostic testing: lab-on-paper. Nanotechnology. 2014;25:094006. doi: 10.1088/0957-4484/25/9/094006. [DOI] [PubMed] [Google Scholar]
  • 27.Shi Q, et al. Utilization of a lateral flow colloidal gold immunoassay strip based on surface-enhanced Raman spectroscopy for ultrasensitive detection of antibiotics in milk. Spectrochim. Acta - Part A Mol. Biomol. Spectrosc. 2018;197:107–113. doi: 10.1016/j.saa.2017.11.045. [DOI] [PubMed] [Google Scholar]
  • 28.Zhang C, et al. Continuous fabrication of nanostructure arrays for flexible surface enhanced Raman scattering substrate. Sci. Rep. 2017;7:1–9. doi: 10.1038/s41598-016-0028-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Cao W, Elsayed-Ali HE. Stability of Ag nanoparticles fabricated by electron beam lithography. Mater. Lett. 2009;63:2263–2266. doi: 10.1016/j.matlet.2009.07.052. [DOI] [Google Scholar]
  • 30.Crupi SM, et al. Self-assembled silver nanoparticles for plasmon-enhanced solar cell back reflectors: correlation between structural and optical properties. Nanotechnology. 2013;24:265601. doi: 10.1088/0957-4484/24/26/265601. [DOI] [PubMed] [Google Scholar]
  • 31.Thouti E, Chander N, Dutta V, Komarala VK. Optical properties of Ag nanoparticle layers deposited on silicon substrates. J. Opt. 2013;15:35005. doi: 10.1088/2040-8978/15/3/035005. [DOI] [Google Scholar]
  • 32.Temple TL, Mahanama GDK, Reehal HS, Bagnall DM. Influence of localized surface plasmon excitation in silver nanoparticles on the performance of silicon solar cells. Sol. Energy Mater. Sol. Cells. 2009;93:1978–1985. doi: 10.1016/j.solmat.2009.07.014. [DOI] [Google Scholar]
  • 33.Araújo, A. Plasmonic Silver Nanoparticles by Dewetting process: Applications in SERS and Thin Film Solar Cells. (Universidade NOVA de Lisboa, 2018).
  • 34.Araújo Andreia, Pimentel Ana, Oliveira Maria João, Mendes Manuel J, Franco Ricardo, Fortunato Elvira, Águas Hugo, Martins Rodrigo. Direct growth of plasmonic nanorod forests on paper substrates for low-cost flexible 3D SERS platforms. Flexible and Printed Electronics. 2017;2(1):014001. doi: 10.1088/2058-8585/2/1/014001. [DOI] [Google Scholar]
  • 35.Jin D, et al. SERS detection of expired tetracycline hydrochloride with an optical fiber nano-probe. Anal. Methods. 2015;7:1307–1312. doi: 10.1039/C4AY02725F. [DOI] [Google Scholar]
  • 36.McGoverin CM, Clark ASS, Holroyd SE, Gordon KC. Raman spectroscopic quantification of milk powder constituents. Anal. Chim. Acta. 2010;673:26–32. doi: 10.1016/j.aca.2010.05.014. [DOI] [PubMed] [Google Scholar]
  • 37.De Gelder J, De Gussem K, Vandenabeele P, Moens L. Reference database of Raman spectra of biological molecules. J. Raman Spectrosc. 2007;38:1133–1147. doi: 10.1002/jrs.1734. [DOI] [Google Scholar]
  • 38.Kuang Y, Jia H, Miyanaga K, Tanji Y. Effect of milk on antibacterial activity of tetracycline against Escherichia coli and Staphylococcus aureus isolated from bovine mastitis. Appl. Microbiol. Biotechnol. 2009;84:135–142. doi: 10.1007/s00253-009-2008-6. [DOI] [PubMed] [Google Scholar]
  • 39.Zhu Jiaji, Chen Quansheng, Kutsanedzie Felix Y. H., Yang Mingxiu, Ouyang Qin, Jiang Hui. Highly sensitive and label-free determination of thiram residue using surface-enhanced Raman spectroscopy (SERS) coupled with paper-based microfluidics. Analytical Methods. 2017;9(43):6186–6193. doi: 10.1039/C7AY01637A. [DOI] [Google Scholar]
  • 40.Li Huanhuan, Chen Quansheng, Mehedi Hassan Md., Chen Xiaoxing, Ouyang Qin, Guo Zhiming, Zhao Jiewen. A magnetite/PMAA nanospheres-targeting SERS aptasensor for tetracycline sensing using mercapto molecules embedded core/shell nanoparticles for signal amplification. Biosensors and Bioelectronics. 2017;92:192–199. doi: 10.1016/j.bios.2017.02.009. [DOI] [PubMed] [Google Scholar]
  • 41.Ouyang Qin, Liu Yan, Chen Quansheng, Guo Zhiming, Zhao Jiewen, Li Huanhuan, Hu Weiwei. Rapid and specific sensing of tetracycline in food using a novel upconversion aptasensor. Food Control. 2017;81:156–163. doi: 10.1016/j.foodcont.2017.06.004. [DOI] [Google Scholar]
  • 42.Food and Drug Administration. Milk Drug Residue Sampling Survey. Silver Spring 10 (2015).
  • 43.Granados-Chinchilla, F. & Rodríguez, C. Tetracyclines in Food and Feedingstuffs: From Regulation to Analytical Methods, Bacterial Resistance, and Environmental and Health Implications. J. Anal. Methods Chem. 2017 (2017). [DOI] [PMC free article] [PubMed]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Information (514.1KB, pdf)
Dataset 1 (5.3MB, xlsx)

Data Availability Statement

The dataset related with this manuscript is available on a separated excel file.


Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES