From Bench to Bedside: Synthesizing Better Replacements and Reconstructions

Benjamin K Potter 1,✉
PMCID: PMC6907320  PMID: 31764326

Total joint replacement surgery represents a resounding success and one of the major medical breakthroughs of the last century. While we continue to grapple with relatively uncommon but severe complications such as infection and instability, total joint replacement is our mainstay that helps restore function and quality of life for hundreds of thousands of patients each year in the United States alone. It also represents virtually the only true success of its kind. Collectively, our track record for the artificial or synthetic replacement of almost any other musculoskeletal structure has been disappointing, at best. We fail—a lot.

Let’s start with artificial ACL replacement. Nearly 34% of Dacron (Deknatel, Fall River, MA, USA) ACL reconstructions developed recurrent instability, while 28% of patients receiving the Gore-Tex (W. L. Gore & Associates, Newark, DE, USA) version developed synovitis and arthrosis [1]. Other synthetic graft types did little better, with frequent rupture, recurrent laxity, synovitis, and arthritis [1, 3, 5, 10]. Synthetic total meniscal replacements and spacers? Ditto [4]. I could go on. And while not, perhaps, an “epic fail” like synthetic ligaments, lumbar disk replacement, at first hailed as the motion-preserving solution to axial back pain and fusion complications, has hardly taken over the world [7].

We shouldn’t necessarily be surprised by these results, as these attempts fly directly in the face of the plastic surgery dictum of “replacing like with like.” But we shouldn’t be unduly discouraged, either. Sir John Charnley started out with an astronomical 8.9% of total hip replacement infections, but he was able to persevere and reduce this to remarkably close to our current levels (1.3%) in just a few short years; for his success in this regard, he was knighted [2]. But we do need to get smarter about our approach to these problems.

A few more-recent attempts make better sense. In general, these devices and techniques seek to augment repairs of biologic tissue or scaffold-based reconstructions rather than permanently, artificially replace what is damaged or missing. For example, Ligament Advanced Reinforcement System (LARS; Surgical Implants and Devices, Arc-sur-Tille, France)-augmented knee ligament reconstructions cause synovitis in a dramatically lower percentage of patients (1% - 2.6%) than other synthetic ligaments [1] and, in some series, have equivalent or better functional and stability outcomes than quadrupled hamstring grafts [6]. Critically, the LARS system is seeking to confer early stability, early return to sport, and protect the biologic reconstruction or repair until adequate healing has occurred; it is not a fake ligament that is supposed to last forever. Afterall, intramedullary nails aren’t replacing the fractured bone, they are attempting to stabilize the fracture and share load until healing occurs; if healing never happens, the nails eventually and predictably break.

We have seen other examples of this. Synthetic meniscal replacement did not work well, but porous meniscal scaffolds show promising results with only 6.1% of more than 600 patients requiring revision [4] and evidence of biologic, fibrous replacement on magnetic resonance imaging and second-look arthroscopy. Modified Broström procedures augmented with an internal brace have demonstrated equivalent clinical outcomes and earlier return to sport than un-augmented procedures [11]. High-grade acromioclavicular joint separations and distal clavicle fractures are increasingly undergoing stabilization with ultra-high strength suture or tape and likewise reflect good clinical results [8]. In each of these cases, we would expect mechanically stable and durable reconstructions because in each instance there is a repaired ligament, a reconstructed ligament, or a broken bone which can heal and then last.

Each of these advances is at least modestly noteworthy in its own right and, in general, represents good news for our technical toolboxes and our patients. But what is really going on (I hope) is that we are finally getting smarter about how we approach these problems. Not every new idea, technique, or device is going to work and hold up to scientific scrutiny or, that ever-lurking destroyer of dreams of grandeur, clinical follow-up. However, we need to continue this trend and be mindful of past fiascos, flops, and disappointments, lest we come to embody Einstein’s definition of insanity. Of course, that didn’t work … again.

Footnotes

A note from the Editor-In-Chief: I am pleased to present the next installment of “From Bench to Bedside,” a quarterly column written by Benjamin K. Potter MD. Dr. Potter is a clinician-scientist in the Uniformed Services University-Walter Reed Department of Surgery. His column investigates important developments that are making—or are about to make—the transition from the laboratory to clinical practice, as well as technologies and approaches that have recently made that jump.

All ICMJE Conflict of Interest Forms for authors and Clinical Orthopaedics and Related Research® editors and board members are on file with the publication and can be viewed on request.

The opinions expressed are those of the writers, and do not reflect the opinion or policy of CORR® or The Association of Bone and Joint Surgeons®.

The author is an employee of the US Government and this work was prepared as part of his official duties. As such, there is no copyright to transfer. The views expressed in this article are those of the author and do not necessarily reflect the official policy or position of the Department of the Army, Department of the Navy, Department of Defense, nor the US Government. I certify that all individuals who qualify as authors have been listed; each has participated in the conception and design of this work, the analysis of data, the writing of the document, and the approval of the submission of this version; that the document represents valid work; that if I used information derived from another source, I obtained all necessary approvals to use it and made appropriate acknowledgements in the document; and that each takes public responsibility for it. Nothing in the presentation implies any Federal/DOA/DON/DOD endorsement. The author received no financial support for this editorial.

Clinical Orthopaedics and Related Research® neither advocates nor endorses the use of any treatment, drug, or device. Readers are encouraged to always seek additional information, including FDA approval status, of any drug or device before clinical use.

References

  • 1.Batty LM, Norsworthy CJ, Lash NJ, Wasiak J, Richmond AK, Feller JA. Synthetic devices for reconstructive surgery on the cruciate ligaments: A systematic review. Arthroscopy . 2015;31:957-968. [DOI] [PubMed] [Google Scholar]
  • 2.Charnley J. Postoperative infection in total prosthetic replacement arthroplasty of the hip-joint: With special reference to the bacterial content of the air of the operating room. Br J Surg . 1969;56:614-649. [DOI] [PubMed] [Google Scholar]
  • 3.Di Giovine NM, Shields CL. Synthetic ligaments in ACL reconstruction: A review. Am Knee Surg . 1991;4:42-48. [Google Scholar]
  • 4.Filardo G, Andriolo L, Kon E, de Caro F, Marcacci M. Meniscal scaffolds: Results and indications. A systematic literature review. Int Orthop. 2015;39:35-46. [DOI] [PubMed] [Google Scholar]
  • 5.Gillquist J, Odensten M. Reconstruction of old anterior cruciate ligament tears with a Dacron prosthesis: A prospective study. Am J Sports Med. 1993;21:358-366. [DOI] [PubMed] [Google Scholar]
  • 6.Hamido F, Al Harran H, Al Misfer AR, El Khadrawe T, Morsy MG, Talaat A, Elias A, Nagi A. Augmented short undersized hamstring tendon graft with LARS artificial ligament versus four-strand hamstring tendon in anterior cruciate ligament reconstruction: Preliminary results. Orthop Trauma Surg Res. 2015;101:535-538. [DOI] [PubMed] [Google Scholar]
  • 7.Pettine K, Ryu R, Techy F. Why lumbar artificial disk replacements (LADRs) fail. Clinical Spine Surg . 2017;30:743-747. [DOI] [PubMed] [Google Scholar]
  • 8.Scheibel M, Dorschel S, Gerhardt C, Kraus N. Arthroscopically assisted stabilization of acute high-grade acromioclavicular joint separations. Am J Sports Med . 2011;39:1507-1515. [DOI] [PubMed] [Google Scholar]
  • 9.Tulloch SJ, Devitt BM, Porter T, Hartwig T, Klemm H, Hookway S, Norsworthy CJ. Primary ACL reconstruction using the LARS device is associated with high failure rate at a minimum of 6-year follow-up. Knee Surg Sport Traumatol Arthrosc. [Published online ahead of print March 22, 2019]. DOI: 10.1007/s00167-019-05478-3. [DOI] [PubMed]
  • 10.Ventura A, Terzaghi C, Legnani C, Albisetti W. Synthetic grafts for anterior cruciate ligament rupture: 19-year study. Knee . 2010;17:108-113. [DOI] [PubMed] [Google Scholar]
  • 11.Yoo J-S, Yang E-A. Clinical results of an arthroscopic modified Brostrom operation with and without an internal brace. J Orthop Traumatology . 2016;17:353-360. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Clinical Orthopaedics and Related Research are provided here courtesy of The Association of Bone and Joint Surgeons

RESOURCES