Abstract
This study describes a new two-step process to cool the thermal vibration of microcantilevers. The process combines active mechanical feedback cooling and optical cavity cooling. A micro-Fabry–Perot interferometer, built in-house, is set atop a microcantilever to measure the vibration amplitude, the high optical power density of which induces cavity cooling in the optical cavity. Using a two-step cooling procedure, the equivalent temperature of the thermal vibration of a microcantilever is lowered from room temperature to the theoretical cooling limit of 0.063 K, a much lower temperature than that achieved via simple cavity cooling (18 K), and then by mechanical feedback cooling (0.135 K) obtained for the same type of microcantilevers in previous studies. This experimental demonstration showcases a new type of cooling process of the amplitude of thermal vibration for micro-mechanical resonators to a lower temperature and does not need additional cooling using a conventional cryogenic refrigerator.
Subject terms: Nanoscience and technology, Optics and photonics, Physics
Introduction
There have been several proposals and attempts1–4 to decrease, as much as possible, the amplitude of thermal vibration of micro-resonators, ideally down to the quantum limit5–7. One such proposal uses a silicon microcantilever. Methods for damping thermal vibration fall into three categories. The first is direct cryogenic cooling of the microcantilever, in which all of the vibration modes are equally cooled, but the experimental system for this is very large and complex8–10. The second is active mechanical feedback damping of the vibration amplitude11–14, in which only selected vibration modes are cooled down15. The feedback control system becomes sensitive to external vibration, but is relatively small. The third is a self-cooling method called cavity damping by which the amplitude of a thermal vibration is damped using bolometric effects16–18 or quantum effects19. The system for this is simple and small.
There have been a few trials with two-step cooling processes using initially a cryogenic means and then mechanical feedback that have lowered the temperature of cantilevers11. However, there has been no study of two-step cooling processes using feedback and then cavity cooling, as far as we know. This study demonstrates the latter two-step cooling using simultaneously mechanical-feedback and optical-cavity cooling.
Methods
The experimental setup for the hybrid cooling of the vibration amplitude of a silicon microcantilever [Fig. 1(A)] consists of a mechanical cantilever for an atomic force microscope that is commercially available with a length, width, and thickness of 240 µm, 40 µm, and about 2 µm, respectively20. The catalog value of the spring constant k is given as approximately 2 N/m. The natural frequencies of the microlever are f0 = 58.4 kHz and 76.2 kHz. One side of each cantilever was gold-coated via ion sputtering to construct a Fabry–Perot interferometer with a reflectance of about 90%21. The Fabry–Perot interferometer has a flat dielectric paring mirror with a reflectance of 92%. The finesse of the interferometer was measured to be 2521. The cantilever was mounted on a single layer piezoelectric transducer (PZT) for precise movements. The system was placed in a vacuum chamber evacuated down to 5 × 10−3 Pa using an oil diffusion vacuum pump.
Figure 1.

(A) Experimental setup for two-step damping of the thermal vibration using a positive mechanical feedback cooling and passive cavity cooling. (B) Typical reflection signal of the micro-Fabry–Perot interferometer as a function of cavity length. Green dotted line is the relative optical power in the cavity. Red open circles mark the operation points of “cavity heating”, and blue open squares mark the operation points of “cavity cooling”.
The vibration amplitude of the silicon microlever was measured by the Fabry–Perot interferometer. A He–Ne laser producing a beam of wavelength 632.8 nm was used as a light source for the interferometer. Using an optical attenuator, the laser power of the interferometer can be varied from 0 to 850 µW. The output signal of the interferometer was passed through a band-pass filter with a bandwidth of 13 kHz. The signal phase was delayed by 90° to dampen the vibration amplitude12. The loop gain g of the feedback control was changed by altering the amplification ratio of the drive voltage of the PZT. Being the gain of the feedback loop, g is defined as the ratio of the movement of the PZT to that of the cantilever. The entire experimental system was placed on an anti-vibration table, and the interferometer system and the microcantilever were mounted on a plate supported by soft rubber blocks in the vacuum chamber to isolate both from further vibration. The output signal from the photodetector was recorded and processed using a fast Fourier transform spectral analyzer. The quality factor Q of the resonance was measured to be around 7000. When also measured for the same silicon cantilever without gold coating, the Q value was up around 1.0 × 105 12, which means that the gold coating increased the damping factor and decreased Q.
Cavity cooling is considered to be induced by the delay of thermal conduction in the gold-coated silicon cantilever and is a type of passive thermal feedback damping16. Therefore, cavity cooling in this experimental system has occurred spontaneously.
Typical reflection signals of the Fabry–Perot interferometer as a function of the gap length of the optical cavity [Fig. 1(B)] show an inverted reflection signal (green dotted line), which is just the relative optical power in the cavity. The operation point of the interferometer was automatically kept on the cooling points of the cavity by changing the cavity gap length using a PZT (length control). These cavity cooling points, indicated by open blue squares in Fig. 1(B), were found in this experimental setup by adjusting the optical alignment of the Fabry–Perot interferometer; see Supplementary Materials.
For various He–Ne laser powers in the cavity-cooling mode, without mechanical feedback cooling, the vibration power spectral densities (PSDs) of the microcantilever were obtained [Fig. 2(A)] from which the vibration amplitude and spectral width were calculated [Fig. 2(B)]. The behaviors of the spectrum width and vibration amplitude are the same as those obtained from mechanical feedback cooling and obtained with increasing mechanical gain. Therefore, the laser power in the former case is considered to correspond to the mechanical feedback gain in the latter. The vibration amplitude is obtained by integrating the PSD with respect to frequency, and taking the square root. We see an increase in width of the PSD, as well as a decrease in vibration amplitude with increasing laser power. The behaviors of these two experimental parameters (spectrum width and peak value) are the same as those for mechanical feedback cooling, both of which were obtained with increasing mechanical gain. Therefore, the laser power in the former case is considered to correspond to the mechanical feedback gain in the latter. The amplitude was calculated to be 5.3 pm, which corresponds to an equivalent temperature of 4.0 K.
Figure 2.

(A) Changes in the power spectrum density of the microcantilever induced by optical cavity cooling for various He–Ne laser power, without mechanical feedback cooling. (B) Vibration amplitude and spectral width as a function of He–Ne laser power, calculated using the data in (A).
When the operational points were set [Fig. 1(B), red open circles], cavity heating occurred and the amplitude increased to the saturation level of the measurement system (about 10 nm).
Figure 3(A) shows the PSD of the vibration amplitude for various mechanical feedback gains in the two-step cooling experiment. The power of the He–Ne laser was set to 850 µW to maximize the effect of optical cooling. Figure 3(B) shows the vibration amplitude, obtained by integrating the PSD over the spectrum. As the feedback gain increased, the amplitude of the thermal vibration decreased, and the minimum amplitude of about 0.7 pm was obtained for g ≅ 0.03.
Figure 3.

(A) Power spectral density of the vibration amplitude for various mechanical feedback gains in the two-step cooling experiment. He–Ne laser power is 850 µW. (B) Vibration amplitude obtained by a two-step operation of cavity cooling and conventional mechanical feedback cooling as a function of mechanical feedback gain. Dotted black line marks the theoretical limit to attain the minimum vibration amplitude of 0. 66 pm22.
For higher values of g (not included in this figure), an oscillation of the feedback system appeared with an amplitude reaching the saturation level of the measurement system (about 10 nm)
The theoretical thermal vibration amplitude was calculated to be 4.5 × 10−11 m (45 pm), assuming that the energy kBT/2 is distributed as an average potential energy; here, kB is Boltzmann’s constant, and T the ambient temperature (300 K)12.
The theoretical minimum attainable amplitude of 0.66 pm [Fig. 3(B); dotted black line] was obtained via the effective cooling temperature Teff,min given by11,22
where k denotes the spring constant of the cantilever, T the initial effective temperature of the resonators for g = 0, ω0 the natural angular frequency of the cantilever, and Sn the PSDs of the floor noise. Here, T equals 4.0 K, ω0 is 2π × 7.62 × 104 rad/sec, Sn is 1 × 10−4 pm2/Hz, and Q is 7000. Therefore, Teff,min evaluates to 0.063 K, corresponding to an amplitude xeff,min = 0.66 pm.
In conclusion, a new two-step process was demonstrated for cooling the thermal vibration of a microcantilever. This process involves optical cavity cooling and mechanical feedback control applied simultaneously. The experimentally obtained minimum temperature is in good agreement with the theoretical cooling limit, which was calculated using the initial effective temperature and the floor noise obtained through cavity cooling.
Data availability
The author declares that all the relevant data supporting the findings of this study are available within the article or from the corresponding author upon request.
Supplementary information
Author contributions
Y. Kawamura wrote the main manuscript and drew up all figures and also contributed to the experiments and review of the manuscript.
Competing interests
The author declares no competing interests.
Footnotes
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
is available for this paper at 10.1038/s41598-019-55496-x.
References
- 1.LaHaye MD, Buu O, Camarota B, Schwab KC. Approaching the Quantum Limit of a Nanomechanical Resonator. Science. 2004;304:74–77. doi: 10.1126/science.1094419. [DOI] [PubMed] [Google Scholar]
- 2.Wilson-Rae I, Zeller P, Imamoglu A. Laser cooling of a nanomechanical resonator mode to its quantum ground state. Phys. Rev., Lett. 2004;92:075507-1–075507-4. doi: 10.1103/PhysRevLett.92.075507. [DOI] [PubMed] [Google Scholar]
- 3.Marshall W, Simon C, Penrose R, Bouweester D. Towards quantum superposition of a mirror. Phys. Rev. Lett. 2003;91:130401-1–130401-4. doi: 10.1103/PhysRevLett.91.130401. [DOI] [PubMed] [Google Scholar]
- 4.Schwab KC, Roukes ML. Putting mechanics into quantum mechanics. Physics Today. 2005;58:36–42. doi: 10.1063/1.2012461. [DOI] [Google Scholar]
- 5.Mamin HJ, Rugar D. Sub-attonewton force detection at millikelvin temperatures. App. Phys. Lett. 2001;79:3358–3360. doi: 10.1063/1.1418256. [DOI] [Google Scholar]
- 6.Stowe TD, et al. Attonewton force detection using ultrathin silicon cantilevers. Appl. Phys. Lett. 1997;71:288–290. doi: 10.1063/1.119522. [DOI] [Google Scholar]
- 7.Sidles JA, et al. Magnetic resonance force microscopy. Rev. Mod. Phys. 1995;67:249–265. doi: 10.1103/RevModPhys.67.249. [DOI] [Google Scholar]
- 8.Knobel RG, Cleland AN. Nanometre-scale displacement sensing using a single electron transistor. Nature. 2003;424:291–293. doi: 10.1038/nature01773. [DOI] [PubMed] [Google Scholar]
- 9.Sazonova V, et al. A tunable carbon nanotube electromechanical oscillator. Nature. 2004;431:284–287. doi: 10.1038/nature02905. [DOI] [PubMed] [Google Scholar]
- 10.O’Connell AD, et al. Quantum ground state and single-phonon control of a mechanical resonator. Nature. 2010;464:697–703. doi: 10.1038/nature08967. [DOI] [PubMed] [Google Scholar]
- 11.Poggio M, Degen CL, Mamin HJ, Rugar D. Feedback cooling of a cantilever’s fundamental mode below 5mK. Physical Review Letters. 2007;99:017201. doi: 10.1103/PhysRevLett.99.017201. [DOI] [PubMed] [Google Scholar]
- 12.Kawamura Y, Kanegae R. Feedback damping of a microcantilever at room temperature to the minimum vibration amplitude limited by the noise level. Sci. Rep. 2016;6:27843. doi: 10.1038/srep27843. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Kleckner D, Bouwmeester D. Sub-kelvin optical cooling of a micromechanical resonator. Nature. 2006;444:75–78. doi: 10.1038/nature05231. [DOI] [PubMed] [Google Scholar]
- 14.Cohadon PF, Heidmann A, Pinard M. Cooling of a Mirror by Radiation Pressure. Physical Rev. Lett. 1999;83:3174–3177. doi: 10.1103/PhysRevLett.83.3174. [DOI] [Google Scholar]
- 15.Kawamura Y, Kanegae R. Mode-selective control of thermal Brownian vibration of micro-resonator (Generation of a thermal non-equilibrium state by mechanical feedback control) Apply. Phys. Lett. 2017;111:133112 -1–133112-3. doi: 10.1063/1.5003615. [DOI] [Google Scholar]
- 16.Metzger CH, Karrai K. Cavity cooling of a microlever. Nature. 2004;432:1002–1005. doi: 10.1038/nature03118. [DOI] [PubMed] [Google Scholar]
- 17.Kleckner D, et al. High finess opto-mechanical cavity with a mobile thirty-micron size mirror. Phys. Rev. Lett. 2006;96:173901-1–173901-4. doi: 10.1103/PhysRevLett.96.173901. [DOI] [PubMed] [Google Scholar]
- 18.Vogel M, Mooser C, Karrai K, Warburton RJ. Optically tunable mechanics of microlevers. Apply. Phys. Lett. 2003;83:829–830. doi: 10.1063/1.1600513. [DOI] [Google Scholar]
- 19.Usami K, et al. Optical cavity cooling of mechanical modes of a semiconductor nanomembrane. Nature Physics. 2012;18:168–172. doi: 10.1038/nphys2196. [DOI] [Google Scholar]
- 20.Binning G, Quate CF, Gerber C. Atomic force microscope. Phys. Rev. Lett. 1986;56:930–933. doi: 10.1103/PhysRevLett.56.930. [DOI] [PubMed] [Google Scholar]
- 21.Tsujiie Y. & Kawamura Y. Micro Fabry-Pérot Interferometer at Rayleigh Range, Sci. Rep. 8, Article number 15193 (2018). [DOI] [PMC free article] [PubMed]
- 22.Poot M, van der Zant HSJ. “Mechanical systems in the quantum regime”. Physics Reports. 2012;511:p273–335. doi: 10.1016/j.physrep.2011.12.004. [DOI] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The author declares that all the relevant data supporting the findings of this study are available within the article or from the corresponding author upon request.
