Daily dataset on temperature and relative humidity in two traditional Basque architectural models located in Lea river valley

Matxalen Etxebarria Mallea a,, Lauren Etxepare Igiñiz a, Margarita de Luxán García de Diego b
PMCID: PMC6920385  PMID: 31886365

Abstract

This data article compares two daily datasets of temperature and relative humidity in two traditional Basque architectural models (B1, B2) located in Lea river valley (Basque Country, Northern Spain). The datasets are drawn from two different approaches to data collection, computer-based simulation and an in-situ monitoring. For this purpose, machine-learning models of the two traditionally constructed buildings were developed and simulated according to annual periods under their SWEC reference climate. These data were compared to the datasets derived from the indoor monitoring campaign, in which hygrothermal variables in two thermal zones of each building (B1_Z1, B1_Z2; B2_Z1, B2_Z2) were measured between September 2018 and September 2019. Accordingly, outdoor climate data were acquired from the nearest weather station (Iruzubieta, Ziortza-Bolibar).

Keywords: Indoor hygrothermal monitoring, Indoor hygrothermal simulation, Traditional architecture


Specifications Table

Subject Construction and architecture
Specific subject area Building physics: outdoor and indoor environments monitoring and simulating
Type of data Tables and figures
How data were acquired Data were acquired in two buildings (B1, B2) with regard to two comparable approaches: machine learning models' hygrothermal data (EnergyPlus 8.6 simulation tool through DesignBuilder v.5.0.1.024 interface) vs indoor monitoring campaign through temperature and relative humidity sensors (SenNet DR-30-24 datalogger and SenNet DL THL-I measuring devices)
Data format Raw, analyzed and filtered
Parameters for data collection The selected traditionally constructed buildings had to represent different construction periods, belong to different construction types, hence, describe different thermal envelope construction characteristics, be located facing the southeast or south, be unoccupied (even if used at times) and non-thermally intervened. In addition, thermal zones facing the main solar façade were favoured for indoor temperature and relative humidity measurements and simulation.
Description of data collection The measurement devices for the hygrothermal monitoring campaign were set up in two thermal zones of each building (ground floor: B1_Z1, B2_Z1; first floor: B1_Z2, B2_Z2), while the computer-based models considered all thermal zones of each building for the simulation process. However, from the hygrothermal dataset obtained, the ones corresponding to the monitored zones were extracted. Accordingly, local climate data from the nearest weather station was collected during the monitoring campaign.
Data source location B1_building: Barrenetxea Farmhouse (43.255307, −2.583003)
B2_building: Barrutieta Farmhouse (43.257857, −2.589525)
Town/Region: Munitibar-Arbatzegi-Gerrikaitz (Basque Country)
Country: Spain
Data accessibility With the article
Related research article M. Etxebarria Mallea, L. Etxepare Igiñiz, M. De Luxán García de Diego, Passive hygrothermal behaviour and indoor comfort concerning the construction evolution of the traditional
Basque architectural model. Lea valley case study, Building and Environment 143 (2018) 496–512, https://doi.org/10.1016/j.buildenv.2018.06.041
Value of the Data
  • The data show the indoor hygrothermal behaviour of the traditional Basque architectural model and describe traditional construction envelopes' thermal physics.

  • The data could be used as basis for further comparison between in-situ measurements and computer simulations theoretical data.

  • The data is valuable to construction project professionals and could also be suitable for heritage intervention regulations development, so that respectful and more efficient intervention criteria could be defined according to real feedback.

  • The data could be useful for researchers evaluating the variation of indoor hygrothermal environments in different outdoor conditions.

1. Data description

The data shown in this article provide additional and complementary data to the already published article « Passive hygrothermal behaviour and indoor comfort concerning the construction evolution of the traditional Basque architectural model. Lea valley case study» [1], and they describe both computer-simulation-based and in-situ monitoring hygrothermal data (temperature and relative humidity) on daily basis (Tables 1–4 of the supplementary file).

The data correspond to the Renaissance model Barrenetxea (B1, Fig. 1, Tables 1–2) and to the Baroque model Barrutieta (B2, Fig. 2, Tables 3–4). The dataset describes the indoor hygrothermal behaviour of two thermal zones located in each traditional building, that is, B1_Z1, B1_Z2 in Barrenetxea and B2_Z1, B2_Z2, instead, in Barrutieta.

Fig. 1.

Fig. 1

Barrenetxea farmhouse (B1). Main façade's current photo, ground floor and first floor. Own elaboration.

Fig. 2.

Fig. 2

Barrutieta farmhouse (B2). Main façade's current photo, ground floor and first floor. Own elaboration.

In addition to indoor data, the provided dataset includes outdoor climate data too; simulation data refer to San Sebastian-SWEC reference climate data [2], while local climate data correspond to the weather station located in Iruzubieta (Ziortza-Bolibar municipality, 10km far from the buildings), which belongs to the Basque Meteorology Agency-Euskalmet [3].

With regard to data comprehension, computer-based dataset illustrates completely passive buildings, that is, with no active energy generation systems switched on, while monitoring data, even if almost all describe passive states, vary between passive and active values. The active energy generation system used was a fireplace, which warmed the entire building up from its location in the monitored ground floor thermal zones (B1_Z1, B2_Z1).

2. Experimental design, materials, and methods

Machine-learning models were developed with EnergyPlus 8.6 simulation tool through DesignBuilder v.5.0.1.024 interface, evaluated a climatic annual period and followed the method described in the previously mentioned article [1].

Indoor temperature (Ta) and relative humidity (HR) monitoring included a SenNet DR-30-24 datalogger and two SenNet DL THL-I measuring devices per building (one in each thermal zone), which automatically gathered data every 15 minutes. The data shown, however, describe daily basis.

The monitored and simulated thermal zones were two in each building:

  • Barrenetxea farmhouse (B1, Fig. 1):
    • Ground floor thermal zone (B1_Z1): useful area of 6.24m2, sandstone masonry wall (e = 40cm), facing the southeast
    • First floor thermal zone (B1_Z2): useful area of 8.48m2, sandstone masonry + timber framework wall (e = 25cm), facing the southeast
  • Barrutieta farmhouse (B2, Fig. 2):
    • Ground floor thermal zone (B2_Z1): useful area of 13.62m2, sandstone masonry wall (e = 70cm), facing the south
    • First floor thermal zone (B2_Z2): useful area of 16.56m2, sandstone masonry + timber framework wall (e = 18cm), facing the south

The monitoring campaign covered almost a year in each building, including unmeasured intervals due to technical failures:

  • Barrenetxea farmhouse (B1): October 23rd 2018–September 30th 2019

  • Barrutieta farmhouse (B2): September 21st 2018–August 31st 2019

Acknowledgments

This research work is part of the corresponding author's Doctoral Thesis that aims to investigate and define the hygrothermal and architectural identity of the Valley of Lea River, and is being developed thanks to the Predoctoral Training Programme for Non-Doctor Research Personnel of the Department of Education, Language Policy and Culture of the Basque Government (PRE_2015_1_0082) and to the financial support provided by the Department of Architecture of the University of the Basque Country (UPV/EHU) for acquiring the monitoring equipment. The owners of the buildings and the useful documentary information provided by the Centre of Cultural Heritage of the Basque Government are also gratefully acknowledged.

Footnotes

Appendix A

Supplementary data to this article can be found online at https://doi.org/10.1016/j.dib.2019.104940.

Conflict of Interest

The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: Department of Architecture of the University of the Basque Country (UPV/EHU) to acquire the monitoring equipment and launch the in-situ measurements.

Appendix A. Supplementary data

The following is the Supplementary data to this article:

Multimedia component 1
mmc1.xlsx (106.4KB, xlsx)

References

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Multimedia component 1
mmc1.xlsx (106.4KB, xlsx)

Articles from Data in Brief are provided here courtesy of Elsevier

RESOURCES