To the Editor:
Pierre Robin sequence (PRS) is defined as the clinical triad of micrognathia, glossoptosis, and airway obstruction. Proper airway management is necessary during infancy because children with PRS frequently experience respiratory failure in early life [1]. There are some reports that a laryngeal mask airway (LMA) and the Air-Q® (Mercury Medical, Clearwater, FL, USA) are effective for airway management in patients with PRS [2, 3]. There are also some reports that the i-gel™ (Intersurgical, Wokingham, UK) is more effective than an LMA because inserting an i-gel™ takes less time than inserting an LMA [4, 5]; furthermore, the i-gel™ has greater leak pressure than the LMA [5]. However, there are no case reports regarding tracheostomy of infants with PRS, especially young infants approximately 1 month old, using an i-gel™. Therefore, we evaluated the use of the i-gel™ as a supraglottic airway device (SGA) during this procedure.
The patient was a 46-day-old boy with a height of 49 cm and a weight of 2.6 kg. He was born at 37 weeks and weighed 1970 g. He was diagnosed with PRS because he had micrognathia and a cleft palate at birth. The patient’s pharyngeal view was categorized as Mallampati class IV. It was possible to fit a mask to his face. A tracheostomy was scheduled because of worsening airway obstruction.
Preanesthetic medication was not administered. An intravenous catheter was placed before the patient entered the operating room. Electrocardiography, percutaneous oxygen saturation, and noninvasive arterial blood pressure were monitored after the patient entered the operating room. We induced general anesthesia after preoxygenating the patient with 5 L/min oxygen for 3 min. First, we administered 0.06 mg intravenous injection (IV) atropine, 6 μg IV fentanyl, and 6 mg IV propofol. We were able to provide ventilation via a mask; subsequently, we administered 3 mg of IV rocuronium. We then attempted to intubate the patient with an uncuffed endotracheal tube (3.0 mm internal diameter) using an AirWay Scope™ (AWS™, Pentax, Humburg, DE). However, we could not visualize the vocal cords (Cormach-Lehane grade 4). We knew that attempts at tracheal intubation frequently lead to laryngeal edema and the inability to provide ventilation. Therefore, we inserted an i-gel™ (size1). We were able to provide ventilation via the i-gel™, and thought that it would be possible to perform a tracheostomy if we could provide ventilation via the i-gel™ using rocuronium to open the glottis. Anesthesia was maintained with a gas mixture of oxygen, air (fraction of inspired oxygen (FIO2), 0.3–0.7) and sevoflurane (1–1.5%), and remifentanil (0.1–0.5 μg/kg/min) and rocuronium (single injection of 1.5 mg) were administered. We were able to perform a tracheostomy and surgery without complications.
We successfully used an i-gel™ for anesthetic management of an infant with PRS who was undergoing tracheostomy.
Acknowledgments
I would like to thank American Journal Experts® for the English language editing.
Funding
No funding was received.
Availability of data and materials
Data sharing not applicable to this article as no data sets were generated or analyzed during the current study.
Abbreviations
- AWS™
AirWay Scope™
- IV
Intravenous injection
- LMA
Laryngeal mask airway
- PRS
Pierre Robin sequence
- SGA
Supraglottic airway device
Authors’ contributions
KO collected the patient data and drafted the manuscript. TM revised the manuscript. Both authors read and approved the final manuscript.
Authors’ information
The corresponding author’s secondary institution is Shizuoka Children’s Hospital, Japan.
Ethics approval and consent to participate
Written informed consent was obtained from the parents of this patient for publication of this case report and any accompanying images.
Consent for publication
Written informed consent for publication was obtained from the parents of this patient.
Competing interests
The authors declare that they have no competing interests.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Contributor Information
Keisuke Omiya, Email: k.omiya0303@gmail.com.
Takashi Matsukawa, Email: takashim@yamanashi.ac.jp.
References
- 1.Van den Elzn AP, Semmekrot BA, Bongers EM, Huygen PL, Marres HA. Diagnosis and treatment of the Pierre Robin sequence: results of a retrospective clinical study and review of the literature. Eur J Pediatr. 2001;160:47–53. doi: 10.1007/s004310000646. [DOI] [PubMed] [Google Scholar]
- 2.Templeton TW, Bryan YE. A two-stage approach to induction and intubation of two infants with Pierre Robin sequence using a LMA Classic™ and Air-Q®: two cases report. Korean J Anesthesiol. 2016;69:390–394. doi: 10.4097/kjae.2016.69.4.390. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Iwai H, Kanai R, Takasu Y, Hirabayashi Y, Seo N. Successful tracheal intubation using the pediatric Airtraq optical laryngoscope in a pediatric patient with Robin sequence. Masui. 2011;60:189–191. [PubMed] [Google Scholar]
- 4.Lee JR, Kim MS, Kim JT, Byon HJ, Park YH, Hs K, et al. A randomised trial comparing the i-gel™ with the LMA Classic™ in children. Anaesthesia. 2012;67:606–611. doi: 10.1111/j.1365-2044.2012.07072.x. [DOI] [PubMed] [Google Scholar]
- 5.Lee YC, Yoon KS, Park SY, Choi SR, Chung CJ. A comparison of i-gel™ and Laryngeal Mask Airway Supreme™ during general anesthesia in infants. Korean J Anesthesiol. 2018;71:37–42. doi: 10.4097/kjae.2018.71.1.37. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
Data sharing not applicable to this article as no data sets were generated or analyzed during the current study.
