Abstract
Voltammetric analysis of mercury ions was developed using paste electrodes (PEs) with DNA and carbon nanotube mixed electrodes. The optimized analytical results of the cyclic voltammetry (CV) of the 1∼14 ng L−1 Hg(II) concentration and the square wave (SW) stripping voltammetry of the 1∼12 ng L−1 Hg(II) working range within an accumulation time of 400 seconds were obtained in 0.1 M NH4H2PO4 electrolyte solutions of pH 4.0. For the relative standard deviations of the 1 ng L−1 Hg(II), which were observed at 0.078% (n = 15) at the optimum conditions, the low detection limit (S/N) was pegged at 0.2 ng L−1 (7.37 × 10−13M) for Hg(II). The results can be applied to assays in biological fish kidneys and wastewater samples.
Key words: Hg(II), DNA, Carbon nanotube, Voltammetry, Fish kidney
References
- Bailure SS, Wlodzimierz K, Francis D. Electro-catalytic properties and sensor applications of fullerenes and carbon nanotubes. Electroanalysis. 2003;9:753–772. [Google Scholar]
- Carrington CD, Montwill B, Bolger PM. An intervention analysis for the reduction of exposure to meth-ylmercury from the consumption of seafood by women of child-bearing age. Reg. Toxicol. Pharmacol. 2004;40:272–280. doi: 10.1016/j.yrtph.2004.07.006. [DOI] [PubMed] [Google Scholar]
- Cizdziel JV, Shawn G. Determination of total mercury in human hair and animal fur by combustion atomic absorption spectrometry. Talanta. 2004;64:918–921. doi: 10.1016/j.talanta.2004.04.013. [DOI] [PubMed] [Google Scholar]
- Claudia MV, Genilson PS, Rodinei A, Fernando BEF, Claudia CW. Speciation and quantication of mercury in Oxisol, Ultisol, and Spodosol from Amazon (Manaus, Brazil) Chemosphere. 2005;58:779–792. doi: 10.1016/j.chemosphere.2004.09.005. [DOI] [PubMed] [Google Scholar]
- Clinio L, Giancarlo T. Voltammetric trace metal determinations by cathodic and anodic stripping voltam-metry in environmental matrices in the presence of mutual interference. J. Electroanal. Chemi. 2001;509:80–89. doi: 10.1016/S0022-0728(01)00422-3. [DOI] [Google Scholar]
- Ertas OS, Tezel H. A validated cold vapour-AAS method for determining mercury in human red blood cells. J. Pharmaceut. Biomed. Anal. 2004;36:893–897. doi: 10.1016/j.jpba.2004.08.014. [DOI] [PubMed] [Google Scholar]
- Eun SC, Kuk RK, Sun TY, Myung HK, Byung WM, Hyun WC. Localization of methyl mercury chloride in the reoroductive tract of male mice. J. Toxicol. Pub. Health. 2003;19:153–159. [Google Scholar]
- Gang W, Jing JX, Hong YC. Interfacing cytochrome Interfacing cytochrome c to electrodes with a DNA-carbonnanotube composite film. Electrochem. Com-mun. 2002;4:506–509. doi: 10.1016/S1388-2481(02)00360-0. [DOI] [Google Scholar]
- Giuseppe C, Elisa BG, Alfredo SM. Multiele-mental speciation analysis of organometallic compounds of mercury, lead and tin in natural water samples by headspace-solid phase microextraction followed by gas chromatography-mass spectrometry. J. Chromato. A. 2004;1034:191–197. doi: 10.1016/j.chroma.2004.01.051. [DOI] [PubMed] [Google Scholar]
- Jahan BR, Reza O, Abolfazl K. Carbon paste electrode spiked with ferrocene carboxylic acid and its application to the electrocatalytic determination of ascorbic acid. J. Electroanal. Chem. 2001;515:45–51. doi: 10.1016/S0022-0728(01)00642-8. [DOI] [Google Scholar]
- Janos V, Erzsebet B. Mercury content of the cultivated mushroom Agaricus bisporus. Food Cont. 2005;16:113–116. doi: 10.1016/j.foodcont.2003.12.004. [DOI] [Google Scholar]
- Joanna B, Michael G. Metals in albatross feathers from midway atoll: Influence of species, age, and nest location. Environ. Res. Section A. 2001;82:207–221. doi: 10.1006/enrs.1999.4015. [DOI] [PubMed] [Google Scholar]
- Joseph W, Beatriz S, Suw YL, Jianmin L, Jose MP. Determination of micromolar bromate concentrations by adsorptive-catalytic stripping votammetry of the molybdenum-3-methoxy-4-hydroxymandelic acid complex. Talanta. 2001;54:147–151. doi: 10.1016/S0039-9140(00)00646-9. [DOI] [PubMed] [Google Scholar]
- Joseph W, Jianmin L, Suw YL, Maika V, Baomin T, William KA, Ruben AA. Lab-on-a-cable for electrochemical monitoring of phenolic contaminants. Anal. Chem. 2000;72:2659–2663. doi: 10.1021/ac991054y. [DOI] [PubMed] [Google Scholar]
- Korbut O, Buckova M, Tarapcik P, Labuda J, Grundler P. Damage to DNA indicated by an electrically heated DNA-modified carbon paste electrode. J. Electroanal. Chem. 2001;506:143–148. doi: 10.1016/S0022-0728(01)00494-6. [DOI] [Google Scholar]
- Li MD, Xiu PY, Yan L, Yan J, Shan WW, Dong QJ. On-line coupling of flow injection displacement sorption preconcentration to high-performance liquid chromatography for speciation analysis of mercury in seafood. J. Chromato. A. 2004;1036:119–125. doi: 10.1016/j.chroma.2004.02.080. [DOI] [PubMed] [Google Scholar]
- Li NL, Gui BJ, Jing FL, Jing TH. Speciation analysis of mercury in seafood by using high-performance liquid chromatography on-line coupled with cold-vapor atomic fluorescence spectrometry via a post column microwave digestion. Anal. Chim. Acta. 2003;477:131–137. doi: 10.1016/S0003-2670(02)01412-5. [DOI] [Google Scholar]
- Manivannan A, Ramakrishnan L, Seehra MS, Granite E, Butler JE, Tryk DA, Fujishima A. Mercury detection at boron doped diamond electrodes using a rotating disk technique. J. Electroanal. Chem. 2005;577:287–293. doi: 10.1016/j.jelechem.2004.12.006. [DOI] [Google Scholar]
- Manli G, Jinhua C, Lihua N, Shouzhuo Y. Electrostatic assembly of calf thymus DNA on multi-walled carbon nanotube modified gold electrode and its interaction with chlorpromazine hydrochlorid. Electrochim. Acta. 2004;49:2637–2643. doi: 10.1016/j.electacta.2004.02.014. [DOI] [Google Scholar]
- Manli G, Jinhua C, Dengyou L, Lihua N, Shouzhuo Y. Electrochemical characteristics of the immobilization of calf thymus DNA molecules on multi-walled carbon nanotubes. Bioelectrochemistry. 2004;62:29–35. doi: 10.1016/j.bioelechem.2003.10.005. [DOI] [PubMed] [Google Scholar]
- Nathalie A, Oscar K, Tom K, Ben A. Low-level methylmercury exposure as a risk factor for neurologic abnormalities in adults. Neurotoxicology. 2005;26:149–157. doi: 10.1016/j.neuro.2004.12.005. [DOI] [PubMed] [Google Scholar]
- Niels PRA, Per HH, Dieter B. Using the electrochemical quartz crystal microbalance as stripping detector. Application to trace mercury analysis. Anal. Chim. Acta. 1996;329:253–256. doi: 10.1016/0003-2670(96)00147-X. [DOI] [Google Scholar]
- Petru J, Freddy CA. Speciation analysis of mercury by solid-phase microextraction and multicapillary gas chromatography hyphenated to inductively coupled plasma-time-of-flight-mass spectrometry. J. Chromato. A. 2004;1055:197–207. doi: 10.1016/j.chroma.2004.09.010. [DOI] [PubMed] [Google Scholar]
- Percio AMF, Angela LRW, Margarida BRB, Adriana TS, Arnaldo AC. Cathodic adsorptive stripping voltammetric behaviour of guanine in the presence of copper at the static mercury drop electrode. Talanta. 2003;61:829–835. doi: 10.1016/S0039-9140(03)00376-X. [DOI] [PubMed] [Google Scholar]
- Radi A. Voltammetric study of khellin at a DNA-coated carbon paste electrode. Anal. Chim. Acta. 1999;386:63–68. doi: 10.1016/S0003-2670(98)00758-2. [DOI] [Google Scholar]
- Ricardo DR, Matthieu W, Philippe M, Christian JC. Measurements of trace concentrations of mercury in sea water by stripping chronopotentiometry with gold disk electrode: influence of copper. Anal. Chim. Acta. 2000;410:97–105. doi: 10.1016/S0003-2670(99)00893-4. [DOI] [Google Scholar]
- Sang HK, Dae KK, Tae YS, Cheol HC. Differential alterations of endotoxin induced cytokine expression and mitogen activated protein kinase activation by mercure in mouse kidney. J. Toxicol. Pub, Health. 2004;20:233–239. [Google Scholar]
- Seung JK, Gyu SR, Soon SK, Kyung HS, So HK, Soo YC, Yo WC, Yong HW, Kui LP. Study on the developmental toxicity of thimerosal. J. Toxicol. Pub. Health. 2003;19:267–275. [Google Scholar]
- Shigehiro K, Yoshiharu K, Yuka S, Kiyoshi H. Rapid determination of total mercury in treated waste water by cold vapor atomic absorption spectrometry in alkaline medium with sodium hypochlorite solution. Talanta. 2004;64:554–557. doi: 10.1016/j.talanta.2004.03.023. [DOI] [PubMed] [Google Scholar]
- Sholupov S, Pogarev S, Ryzhov V, Mashyanov N, Stroganov A. Zeeman atomic absorption spectrometer RA-915+ for direct determination of mercury in air and complex matrix samples. Fuel Proc. Technol. 2004;85:473–485. doi: 10.1016/j.fuproc.2003.11.003. [DOI] [Google Scholar]
- Sonia MS. Determination of lead in the absence of supporting electrolyte using carbon fiber ultramicroelec-trode without mercury film. Electroanalysis. 1998;10:722–725. doi: 10.1002/(SICI)1521-4109(199808)10:10<722::AID-ELAN722>3.0.CO;2-6. [DOI] [Google Scholar]
- Suw YL, Duck HK, Myung HK. Square-wave cathodic stripping voltammetric analysis of RDX using mercury-film plated glassy carbon electrode. Talanta. 2002;58:919–926. doi: 10.1016/S0039-9140(02)00442-3. [DOI] [PubMed] [Google Scholar]
- Suw YL, Jung IC, Young SJ, Woon WJ, Hye JL, Seong HL. Electrochemical detection of ascorbic acid (vitamin C) using a glassy carbon electrode. Nahrung/Food. 2004;48:201–204. doi: 10.1002/food.200300394. [DOI] [PubMed] [Google Scholar]
- Tesfaye HD, Bhagwan SC, Hailemichael A. Electrode, differential pulse anodic stripping voltammetric determination of Lead(II) with N p chlorophenylcinnamo-hydroxamic acid modified carbon paste electrode. Electroanalysis. 1999;17:1305–1311. [Google Scholar]
- Tsai HL, Jing FH, Wen SI. Perfluorinated anion-exchange polymer mercury film electrode for anodic stripping voltammetric determination of zinc(II): effect of model organic compounds. Anal. Chim. Acta. 2001;21701:1–8. [Google Scholar]
- Van Staden JF, Taljaard RE. Determination of Lead(II), Copper(II), Zinc(II), Cobalt(II), Cadmium(II), Iron(III), Mercury(II) using sequential injection extractions. Talanta. 2004;64:1203–1212. doi: 10.1016/j.talanta.2004.06.020. [DOI] [PubMed] [Google Scholar]
- Yuan DZ, Dai WP, Shen H, Zong LW, Jiem KC, Hongm PD. DNA-modified electrodes; part 4: optimization of covalent immobilization of DNA on self-assembled monolayers. Talanta. 1999;49:751–756. doi: 10.1016/S0039-9140(99)00078-8. [DOI] [PubMed] [Google Scholar]
- Zuliang C, Zahra P, Hibbert DB. Stripping vol-tammetry of Pb(II), Cu(II), and Hg(II) at a nafin-coated glassy carbon electrode modifid by neutralionophores. Electroanalysis. 1999;11:964–968. doi: 10.1002/(SICI)1521-4109(199909)11:13<964::AID-ELAN964>3.0.CO;2-3. [DOI] [Google Scholar]