Abstract
Background
The ANZACS‐QI Cardiac Implanted Device Registry (ANZACS‐QI DEVICE) collects nationwide data on cardiac implantable electronic devices in New Zealand (NZ). We used the registry to describe contemporary NZ use of implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT).
Methods
All ICD and CRT Pacemaker implants recorded in ANZACS‐QI DEVICE between 1 January 2014 and 31 December 2017 were analyzed.
Results
Of 1579 ICD implants, 1152 (73.0%) were new implants, including 49.0% for primary prevention and 51.0% for secondary prevention. In both groups, median age was 62 years and patients were predominantly male (81.4% and 79.2%, respectively). Most patients receiving a primary prevention ICD had a history of clinical heart failure (80.4%), NYHA class II‐III symptoms (77.1%) and LVEF ≤35% (96.9%). In the secondary prevention ICD cohort, 88.4% were for sustained ventricular tachycardia or survived cardiac arrest from ventricular arrhythmia. Compared to primary prevention CRT Defibrillators (n = 155), those receiving CRT Pacemakers (n = 175) were older (median age 74 vs 66 years) and more likely to be female (38.3% vs 19.4%). Of the 427 (27.0%) ICD replacements (mean duration 6.3 years), 46.6% had received appropriate device therapy while 17.8% received inappropriate therapy. The ICD implant rate was 119 per million population with regional variation in implant rates, ratio of primary prevention ICD implants, and selection of CRT modality.
Conclusion
In contemporary NZ practice three‐quarters of ICD implants were new implants, of which half were for primary prevention. The majority met current guideline indications. Patients receiving CRT pacemaker were older and more likely to be female.
Keywords: cardiac resynchronization therapy, device therapy, implant rates, Implantable cardioverter defibrillator, New Zealand
This paper utilized the ANZACS‐QI Cardiac Implanted Device Registry to describe contemporary use of implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) in New Zealand. Three‐quarters of ICD implants were new implants, of which half were for primary prevention. Compared to primary prevention CRT Defibrillators, those receiving CRT Pacemakers were older and more likely to be female. The ICD implant rate was 119 per million population with regional variation in implant rates, ratio of primary prevention ICD implants, and selection of CRT modality.
1. INTRODUCTION
Cardiac implantable electronic device (CIED) therapy is an important tool in the management of heart failure with reduced ejection fraction. Implantable cardioverter defibrillators (ICD) are indicated for primary prevention of sudden cardiac death in patients with symptomatic heart failure and left ventricular ejection fraction (LVEF) ≤35% despite optimal medical therapy.1, 2, 3, 4, 5, 6, 7, 8, 9, 10 They are also indicated for secondary prevention in patients who have survived a cardiac arrest or hemodynamically unstable ventricular arrhythmia.1, 9, 10, 11, 12, 13, 14 Cardiac resynchronization therapy (CRT) is indicated in patients with symptomatic heart failure, sinus rhythm, LVEF ≤35%, and a wide QRS despite optimal medical therapy.9, 10, 14, 15, 16, 17, 18 This can be delivered in the form of a CRT Pacemaker (CRT‐P) or a CRT Defibrillator (CRT‐D). Most patients who fulfill conventional indications for CRT have overlapping indications for an ICD.
The All New Zealand Acute Coronary Syndrome‐Quality Improvement Cardiac Implanted Device Registry (ANZACS‐QI DEVICE) is a web‐based platform designed to collect data on CIED implanted across New Zealand (NZ). The registry includes permanent pacemaker (DEVICE‐PPM) and implantable cardioverter defibrillator (DEVICE‐ICD), including both new implants and replacement procedures. It was built upon the ANZACS‐QI platform and introduced to NZ public hospitals in 2014 through a grant from the NZ branch of the Cardiac Society of Australia and New Zealand (CSANZ).19 The ANZACS‐QI DEVICE Registry has been used previously to describe the clinical characteristics and implant details of patients receiving new pacemaker implants.20 Our study aims to describe the contemporary NZ use of ICD and CRT, utilizing the ANZACS‐QI DEVICE Registry.
2. METHODS
All ICD implants (including new and replacement procedures) registered in the ANZACS‐QI DEVICE between 1 January 2014 and 31 December 2017 were analyzed. For the CRT cohort, new primary prevention CRT‐D implants (from DEVICE‐ICD) as well as new CRT‐P implants (from DEVICE‐PPM) over the same study period were analyzed.
Data are entered by cardiac physiologists at the time of the procedure and at the 4‐ to 6‐week follow‐up device clinic. All data extracted from the registries for analysis are anonymized. Although participation in the registry is voluntary, seven of 10 PPM implant sites and five of seven ICD implant sites participated by mid‐2014, with full participation from all implant sites from early 2016. However, there was a drop in participation in early 2017. Details regarding the operation of the ANZACS‐QI registries have been previously reported.19 Both DEVICE‐ICD and DEVICE‐PPM collect procedure numbers, basic patient demographics, symptoms, ECG findings, device indication, device type, implant physician and hospital as well as early complications. Data collected in the DEVICE‐ICD registry also include cardiac and medical history, primary and secondary prevention indication, NYHA class and left ventricular systolic function (in those with a history of clinical heart failure). The CRT‐P cohort of DEVICE‐PPM also has data on NYHA class and left ventricular systolic function as well as additional ECG details.
2.1. Definitions
Appropriate device therapy was defined as the delivery of antitachycardia pacing (ATP) or shocks for ventricular tachycardia (VT) or ventricular fibrillation (VF). Device therapy in the absence of VT or VF was considered to be inappropriate device therapy.
2.2. Statistical analysis
Continuous variables were summarized as means with standard deviation (SD) or medians with interquartile range (IQR). The Student's t test was used to compare groups. For categorical variables, data were summarized as frequency and percentage and the Chi‐square test or Fisher's exact test was used for comparisons between groups where appropriate. All P‐values reported were two‐tailed and a P < .05 was considered significant. Data were analyzed using the SAS statistical package, version 9.4 (SAS Institute). Crude implant rates were calculated using the 2017 Projected New Zealand Population.
2.3. Ethics
ANZACS‐QI is a substudy within the PREDICT study which was approved by the Northern Region Ethics Committee Y in 2003 (AKY/03/12/314) with subsequent annual approval by the National Multi Region Ethics Committee since 2007 (MEC07/19/EXP).
3. RESULTS
There were 1579 ICD implants during this study period, including 1152 (73.0%) new implants and 427 (27.0%) replacement procedures.
3.1. New ICD implants
Of the 1152 new implants, there were 565 (49.0%) primary prevention ICDs and 587 (51.0%) secondary prevention ICDs (Table 1). The clinical characteristics of both groups were similar. The median age was 62 years, predominantly male (81.4% vs 79.2%), with European (63.7% vs 66.8%) and Māori (24.8% vs 21.1%) being the most common ethnicities. The mean BMI was 30.2 vs 29.2 kg/m2. Baseline histories of hypertension, diabetes mellitus, and dyslipidemia were similar in the two groups. A history of atrial fibrillation or atrial flutter was reported in 31.0% vs 33.7% of the primary and secondary prevention groups, respectively. The majority (75.2% vs 80.7%) was in sinus rhythm at the time of ICD implant.
Table 1.
New primary and secondary prevention ICD implant patient characteristics
Primary (n = 565) | Secondary (n = 587) | P | |
---|---|---|---|
Demographics | |||
Age, years | .386 | ||
Median (IQR) | 62 (54‐68) |
62 (53‐70) |
|
Gender, n (%) | .348 | ||
Male | 460 (81.4) | 465 (79.2) | |
Female | 105 (18.6) | 122 (20.8) | |
Ethnicity, n (%) | .337 | ||
European | 360 (63.7) | 392 (66.8) | |
Māori | 140 (24.8) | 124 (21.1) | |
Others | 65 (11.5) | 71 (12.1) | |
BMI (kg/m2) | .059 | ||
Mean ± SD | 30.2 ± 6.5 | 29.6 ± 6.5 | |
Smoking, n (%) | .038 | ||
Never | 248 (43.9) | 257 (43.8) | |
Ex‐smoker | 252 (44.6) | 243 (41.4) | |
Current smoker | 65 (11.5) | 87 (14.8) | |
Medical history | |||
AF/ AFL | .317 | ||
Paroxysmal AF | 56 (9.9) | 89 (15.2) | |
Persistent AF | 31 (5.5) | 21 (3.6) | |
Permanent AF | 74 (13.1) | 71 (12.1) | |
Atrial flutter | 14 (2.5) | 17 (2.9) | |
Hypertension, n (%) | 274 (48.5) | 288 (49.1) | .847 |
Diabetes, n (%) | 133 (23.5) | 107 (18.2) | .027 |
Dyslipidaemia, n (%) | 291 (51.5) | 301 (51.3) | .939 |
Coronary artery disease, n (%) | 279 (49.4) | 336 (57.2) | .008 |
of which Prior MI, n (%) | 191 (68.5) | 254 (75.6) | .049 |
Valvular heart disease, n (%) | 170 (30.1) | 124 (21.1) | .001 |
Other cardiovascular conditions, n (%) | — | ||
Hypertrophic cardiomyopathy | 34 (6.0) | 19 (3.2) | |
Sarcoidosis | 11 (1.9) | 6 (1.0) | |
Congenital heart disease | 8 (1.4) | 10 (1.7) | |
Long QT | 6 (1.1) | 11 (1.9) | |
Brugada | 4 (0.7) | 3 (0.5) | |
ARVC | 3 (0.5) | 13 (2.2) | |
Idiopathic VF | 0 (0) | 8 (1.4) | |
CPVT | 0 (0) | 1 (0.2) | |
Other comorbidities, n (%)a | — | ||
Peripheral vascular disease | 16 (2.8) | 18 (3.1) | |
TIA/stroke | 37 (6.5) | 41 (7.0) | |
Chronic lung disease | 48 (8.5) | 48 (8.2) | |
Chronic renal impairment | 43 (7.6) | 38 (6.5) | |
Anxiety/depressive disorder | 26 (4.6) | 23 (3.9) | |
Sleep apnoea | 46 (8.1) | 31 (5.3) | |
Clinical heart failure, n (%) | 454 (80.4) | 233 (39.7) | <.001 |
NYHA Class | <.001 | ||
I | 80 (17.6) | 84 (36.1) | |
II | 258 (56.8) | 84 (36.1) | |
III | 92 (20.3) | 26 (11.2) | |
IV | 4 (0.9) | 2 (0.9) | |
Unknown | 20 (4.4) | 37 (15.9) | |
LVEF (%) | |||
Mean ± SD | 25.1 ± 6.7 | 30.3 ± 9.3 | <.001 |
≤35% | 440 (96.9) | 177 (76.0) | <.001 |
Aetiology of heart failure | .001 | ||
Ischaemic | 193 (42.5) | 130 (55.8) | |
Non‐ischaemic | 261 (57.5) | 103 (44.2) | |
Estimated GFR (ml/min/1.73 m2) | <.001 | ||
>60 | 406 (71.9) | 480 (81.8) | |
30‐60 | 148 (26.2) | 105 (17.9) | |
<30 | 11 (1.9) | 2 (0.3) | |
ECG Features | |||
ECG at time of implant, n (%) | .043 | ||
Sinus Rhythm | 429 (75.2) | 474 (80.7) | |
2nd degree AVB type 1 | 1 (0.2) | 3 (0.5) | |
2nd degree AVB type 2 | 1 (0.2) | 2 (0.3) | |
Complete heart block | 12 (2.1) | 3 (0.5) | |
Atrial fibrillation/ flutter | 110 (19.5) | 92 (15.7) | |
Ventricular paced | 10 (1.8) | 7 (1.2) | |
Atrial paced | 2 (0.4) | 0 (0) | |
Other | 4 (0.7) | 6 (1.0) | |
QRS duration (msec) | <.001 | ||
Mean ± SD | 129.9 ± 36.4 | 113.4 ± 31.5 | |
QRS duration (msec), n (%) | <.001 | ||
<120 | 265 (46.9) | 383 (65.3) | |
120‐150 | 121 (21.4) | 119 (20.3) | |
>150 | 179 (31.7) | 85 (14.5) | |
Bundle Branch Block, n (%) | |||
LBBB | 180 (31.9) | 94 (16.0) | <.001 |
RBBB | 43 (7.6) | 40 (6.8) | .018 |
Fascicular Block | 13 (2.3) | 15 (2.6) | |
Secondary prevention ICD Indication, n (%)a | |||
VT/VF Cardiac Arrest | N/A | 371 (63.2) | — |
Sustained VT | 148 (25.2) | ||
Non sustained VT | 56 (9.5) | ||
Syncope | 54 (9.2) | ||
Presyncope | 22 (3.7) | ||
Non VT/VF cardiac arrest | 7 (1.2) | ||
Implant details | |||
Device type, n (%) | <.001 | ||
Single | 291 (51.5) | 369 (62.9) | |
Dual | 101 (17.9) | 151 (25.7) | |
CRT | 155 (27.4) | 49 (8.3) | |
Subcutaneous | 18 (3.2) | 18 (3.1) | |
Remote monitoring, n (%) | 495 (87.6) | 534 (91.0) | .065 |
Device testing, n (%) | 50 (8.8) | 144 (24.5) | <.001 |
Number of programmed therapy zones, n (%) | .002 | ||
1 | 122 (21.6) | 81 (13.8) | |
2 | 257 (45.5) | 277 (47.2) | |
3 | 186 (32.9) | 228 (38.8) | |
NZ Standard Device Programming, n (%) | 450 (79.6) | 408 (69.5) | <.001 |
SVT discriminators used, n (%) | 491 (86.9) | 536 (91.3) | .016 |
Complications (up to 6 weeks), n (%) | 43 (7.6) | 23 (3.9) | — |
Death from any cause | 1 (0.2) | 2 (0.3) | |
Cardiac perforation | 2 (0.4) | 0 | |
Pneumothorax | 3 (0.5) | 0 | |
Haematoma | 8 (1.4) | 5 (0.9) | |
Intervention | 4 (0.7) | 3 (0.5) | |
No intervention | 4 (0.7) | 2 (0.3) | |
Re‐operation | 13 (2.3) | 11 (1.9) | |
Lead‐related re‐operation | 12 (2.1) | 10 (1.7) | |
Infection | 16 (2.8) | 5 (0.9) | |
Antibiotics | 13 (2.3) | 5 (0.9) | |
Device removal | 3 (0.5) | 0 |
Abbreviations: AF, atrial fibrillation; AFL, atrial flutter; ARVC, arrhythmogenic right ventricular cardiomyopathy; BMI, body mass index; CPVT, cathecholaminergic polymorphic ventricular tachycardia; GFR, glomerular filtration rate; LBBB, left bundle branch block; LVEF, left ventricular ejection fraction; MI, myocardial infarction; NYHA, New York Heart Association; RBBB, right bundle branch block; SVT, supraventricular tachycardia.; TIA, transient ischaemic attack; VF, ventricular fibrillation; VT, ventricular tachycardia.
More than one option may be selected.
Most patients receiving a primary prevention ICD had a history of clinical heart failure (80.4%) with significant heart failure symptoms (NYHA class II‐III in 77.1%) and severe LV impairment (LVEF ≤ 35% in 96.9%) of those with heart failure. The etiology of heart failure was ischemic in only 42.5%. The mean QRS duration was 130 milliseconds, with 31.9% having left bundle branch block (LBBB). CRT‐D accounted for 27.4% of primary prevention ICD implants.
In the secondary prevention ICD cohort, 88.4% were for VT/VF cardiac arrest or sustained VT. In contrast with the primary prevention ICD cohort, only 39.7% had a history of clinical heart failure, of whom 47.3% had significant heart failure symptoms (NYHA class II‐III) and 76.0% had an LVEF ≤35%. There was a higher rate of ischemic etiology for heart failure at 55.8%. The mean QRS duration was 113 milliseconds, with only 16.0% having LBBB. CRT‐D accounted for only 8.3% of secondary prevention ICD implants.
Overall, the majority of patients had remote monitoring (89.3%), use of standard device programming (74.5%) and use of supraventricular tachycardia (SVT) discriminators (89.1%). Subcutaneous ICDs were implanted in 3.1% of patients. The overall complication rate in the first 6 weeks was 5.7%. Cardiac perforation occurred in 0.2% and pneumothorax in 0.3%. Hematoma occurred in 1.1%, with intervention required in 0.6%. Reoperation was required in 2.1%, including 1.9% for lead‐related reoperation. The rate of infection was 1.8%, with 0.3% requiring device removal. Death from any cause at 6 weeks was recorded in three patients (0.3%), but these patients did not have any other device‐related complications recorded.
3.2. Primary prevention CRT defibrillators and CRT pacemakers
The subgroup of new primary prevention CRT‐D patients (n = 155) was compared with new CRT‐P patients (n = 175). The baseline characteristics are shown in Table 2. NYHA class and LVEF were recorded in all patients with CRT‐P, but only available in those with a history of clinical heart failure (92.3%) in the CRT‐D group. Most patients in both primary prevention CRT‐D and CRT‐P groups had symptomatic heart failure (NYHA ≥II in 89.0% vs 89.2%, P = .492), LBBB (87.7% vs 89.1%, P = .319), and QRS duration >120 milliseconds (120‐150 milliseconds in 19.4% vs 25.7%; >150 milliseconds in 76.8% vs 68.0%; P = .195). Patients who received a CRT‐P were older (median age 74 years vs 66 years, P < .001) and more likely to be female (38.3% vs 19.4%, P < .001). Patients receiving a new primary prevention CRT‐D had longer mean QRS duration (169 milliseconds vs 161 milliseconds, P = .005) and poorer LV systolic function (mean LVEF 24.2% vs 28.7%, P < .001).
Table 2.
New primary prevention CRT‐D and CRT‐P patient characteristics
CRT‐D (n = 155) | CRT‐P (n = 175) | P | |
---|---|---|---|
Demographics | |||
Age, years | <.001 | ||
Median (IQR) | 66 (59‐71) | 74 (66‐77) | |
Gender, n (%) | <.001 | ||
Male | 125 (80.6) | 108 (61.7) | |
Female | 30 (19.4) | 67 (38.3) | |
Ethnicity, n (%) | .071 | ||
European | 120 (77.4) | 152 (86.9) | |
Māori | 25 (16.1) | 15 (8.6) | |
Others | 10 (6.5) | 8 (4.6) | |
AF/AFL, n (%) | .699 | ||
Paroxysmal | 21 (13.5) | 31 (17.7) | |
Persistent AF | 9 (5.8) | 12 (6.9) | |
Permanent AF | 21 (13.5) | 23 (13.1) | |
Atrial flutter | 10 (6.5) | 8 (4.6) | |
NYHA, n (%) a | .492 | ||
I | 15/136 (11.0) | 19 (10.9) | |
II | 74/136 (54.4) | 84 (48.0) | |
III | 45/136 (33.1) | 71 (40.6) | |
IV | 2/136 (1.5) | 1 (0.6) | |
ECG findings | |||
QRS duration (msec) | .005 | ||
Mean ± SD | 169.2 ± 27.9 | 160.8 ± 25.9 | |
QRS duration (msec), n (%) | .195 | ||
<120 | 6 (3.9) | 11 (6.3) | |
120‐150 | 30 (19.4) | 45 (25.7) | |
>150 | 119 (76.8) | 119 (68.0) | |
Bundle Branch Block, n (%) | .319 | ||
LBBB | 136 (87.7) | 156 (89.1) | |
RBBB | 7 (4.5) | 8 (4.6) | |
IVBB | 4 (2.6) | 11 (6.3) | |
LVEFa | |||
Mean ± SD | 24.2 ± 7.0 | 28.7 ± 10.7 | <.001 |
≤35% | 138/143 (96.5) | 144 (82.3) | <.001 |
Complications (up to 6 weeks), n (%) | 17 (11.0) | 13 (7.4) | — |
Death from any cause | 1 (0.6) | 0 | |
Pneumothorax | 2 (1.3) | 2 (1.1) | |
Haematoma | 2 (1.3) | 0 | |
Intervention | 1 (0.6) | 0 | |
No intervention | 1 (0.6) | 0 | |
Infection | 9 (5.8) | 2 (1.1) | |
Antibiotics | 8 (5.2) | b | |
Device removal | 1 (0.6) | b | |
Re‐operation | 3 (1.9) | 5 (2.9) | |
Lead‐related re‐operation | 3 (1.9) | 4 (2.3) | |
Coronary sinus dissection | 0 | 4 (2.3) |
In the CRT‐D group, NYHA and LVEF was only recorded in those with a history of heart failure (n = 143, 92.3%).
Data not available.
The overall complication rate in the first 6 weeks was 9.1%. Pneumothorax occurred in 1.2% and coronary sinus dissection in 1.2%. Hematoma occurred in 0.6%, with intervention required in 0.3%. The rate of infection was 3.3%, with 0.3% requiring device removal. Reoperation was required in 2.4%, including 2.1% for lead‐related reoperation. Death from any cause at 6 weeks was recorded in one patient (0.3%), but this patient did not have any other device‐related complications recorded.
3.3. ICD replacements
In the 427 ICD replacements, 72.6% were for elective replacement indicators and 9.6% were for system upgrades (Table 3). Five (1.2%) were for infection. Over a mean duration of 6.3 ± 2.7 years, 46.6% had received appropriate device therapy (38.4% had shocks or ATP with shocks) while 17.8% had inappropriate device therapy (including ATP and/or shocks) with a mean number of shocks of 3.7 ± 8.2.
Table 3.
ICD replacement cohort characteristics
Device replacement | n = 427 |
---|---|
Duration of device (in years) | n = 406 |
Mean ± SD | 6.27 ± 2.65 |
Reason for replacement, n (%) | |
Elective replacement indicator | 310 (72.6) |
System upgrade | 41 (9.6) |
Infection | 5 (1.2) |
Device recall | 2 (0.5) |
System malfunction | 10 (2.3) |
Other | 59 (13.8) |
Appropriate therapy from device, n (%) | 199 (46.6) |
Shocks | 71 (35.7) |
ATP | 35 (17.6) |
ATP and shocks | 93 (46.7) |
Inappropriate therapy from device | 76 (17.8) |
Total number of shocks from device | |
Mean ± SD | 3.69 ± 8.23 |
Range | 0‐98 |
Abbreviations: ATP, anti‐tachycardia pacing.
3.4. ICD and CRT national and regional implant rates in 2016
As there was participation from all implant sites in 2016, this provided an opportunity to examine implant rates at a national and regional level (Figures 1 and 2). The completeness of data within the ANZACS‐QI DEVICE Registry in 2016 has been validated previously.21 In 2016, there were 560 ICD implants, including new and replacement procedures. This included 122 CRT‐D implants. In comparison, there were 112 CRT‐P implants. This translates to implant rates per million population of 119 for all ICD, 93 for ICD (excluding CRT‐D) and 50 for all CRT (26 CRT‐D and 24 CRT‐P). Primary prevention ICD implants accounted for 52% of new implants.
Figure 1.
Regional variation in ICD and CRT implant rate per million population in 2016. ICD, implantable cardioverter defibrillator; CRT, cardiac resynchronisation therapy
Figure 2.
Regional variation in new primary prevention to secondary prevention ICD implant ratio in 2016. ICD, implantable cardioverter defibrillator
There was significant variation in implant rates and implant practice across the four regions in NZ. The Midlands region had the highest ICD implant rate (163) while the Central region had the lowest ICD implant rate (74) but had the highest CRT‐D to CRT‐P implant ratio (2.7:1). In contrast, the Southern region had the highest rate of CRT‐P implantation (52) and the highest CRT‐P to CRT‐D implant ratio (1.6:1). The Midlands region had the highest new primary prevention ICD implant ratio (62%) while the Southern region had the lowest (39%).
4. DISCUSSION
This is the first study to describe individual level data on ICD and CRT patient characteristics and implant practice at a national level. Implant volumes and types of pacemakers and ICDs have been surveyed regularly across Australia and NZ previously.22 In patients who receive ICD and CRT‐D, previous reports have examined the impact of geographic, ethnic, and socioeconomic impact on implant rates at a national level, while the long‐term outcomes of patients have only been examined at a regional level.23, 24
Three‐quarters of ICD implant procedures in contemporary NZ practice are new implants. Of these, half were for primary prevention indications. The majority of patients receiving a primary prevention ICD had a history of clinical heart failure with significant heart failure symptoms and poor LV systolic function. Most patients receiving secondary prevention ICD were for VT/VF cardiac arrest or sustained VT. CRT‐D was the device type in a quarter of patients receiving an ICD for primary prevention indications but fewer than one‐tenth of those for secondary prevention indications. Of the ICD replacement procedures, nearly three‐quarters were for an elective replacement indication. Nearly half of the patients presenting for an ICD replacement had received at least one appropriate device therapy during the life of the device, and almost a fifth received inappropriate device therapy. There is also significant variation in implant rates and implant practice across the NZ regions, particularly with primary prevention ICD implant ratios and selection of CRT modality.
4.1. New implants—primary vs secondary prevention
The ratio of new primary prevention ICD implants to secondary prevention ICD implants in our cohort was just under 50%. This is essentially unchanged from the last analysis of national ICD implant practice in NZ in 2010.23 The primary prevention ICD implant ratio reported in several international registries over the past decade is as follows: 46% in Denmark, 55% in Germany, 57% in the United Kingdom, 59% in Sweden, 62% in Spain, 63% in France, 73% in Canada, 75% in the United States, and 82% in Italy.25, 26, 27, 28, 29, 30, 31, 32 The proportion of ICDs implanted in NZ for primary prevention indications is thus on the lower end of the range of contemporary international implant practice. There is also variation in primary prevention ICD implant ratio of 39%‐62% across NZ regions. This suggests that we are relatively conservative with our patient selection, which is likely because of the resource constraints, work force limitations and varying interpretation of the evidence and guidelines by implanting centers in NZ. In accordance with international guideline recommendations, most of the patients receiving a primary prevention ICD in our cohort had a history of clinical heart failure, significant heart failure symptoms and LVEF ≤35%. The clinical characteristics of the patients in our cohort were similar to those described in international registries.27, 30 The mean LVEF in the primary prevention group was 25.1%, which was similar to several major primary prevention ICD and CRT‐D trials that had a mean LVEF of 21.4%‐28.0%.2, 3, 4, 5, 6, 7, 15, 16, 18 Interestingly, ischemic etiology for heart failure accounted for only 42.5% of primary prevention ICD implants and 55.8% of secondary prevention ICD implants in our cohort. This is in contrast to other international studies that have reported ischemic etiology for heart failure at rates of 54.0%‐93.0%.25, 28, 29, 30 This trend may change in the coming years following the results of the DANISH study, which has shown no mortality benefit in primary prevention ICD implantation in nonischemic cardiomyopathy.33
4.2. CRT
Patients who received CRT‐P were older and more likely to be female while patients receiving CRT‐D had longer mean QRS duration and poorer LV function. There has been limited evidence directly comparing CRT‐P to CRT‐D, thus current international guidelines do not advocate one modality over the other. In NZ, while the decision to offer CRT‐P or CRT‐D varies across implant centers, it has been our general practice to limit primary prevention ICD implantation in patients >75 years old.10 Female gender has been associated with a “super‐response” to CRT in previous studies, thus women are also more likely to be offered a CRT‐P in NZ.34, 35, 36, 37, 38, 39 This trend is consistent with several contemporary international registries and studies.40, 41, 42, 43 Of note, those studies have shown very similar LV systolic function between the CRT‐P and CRT‐D cohorts, with CRT‐P having a longer mean QRS duration. The longer mean QRS duration and poorer LV systolic function in our CRT‐D cohort compared to our CRT‐P cohort suggests that we are selecting patients with a higher perceived risk for CRT‐D.
4.3. ICD replacements
Of those who came for an ICD replacement, over a mean duration of 6.3 years, 46.6% had received appropriate device therapy (including 38.4% appropriate shocks), while 17.8% had received inappropriate device therapy. Data from the seven major ICD trials in the late 1990s to early 2000s demonstrated the rate of appropriate ICD therapy was 17%‐64% and inappropriate ICD therapy was 10%‐24% over the 20 to 45 month follow‐up period.2, 3, 4, 5, 6, 7, 13, 44, 45 Contemporary device programming to reduce inappropriate shocks, combined with broader indications for primary prevention ICD implantation, have lowered the rate of appropriate and inappropriate device therapy.45 The rate of appropriate and inappropriate device therapy in our cohort is comparable to contemporary data from United States, Canada, and Denmark.30, 46, 47
4.4. Implant rates and regional variation
Our national ICD implant rate of 119 per million in 2016 has increased over time with previous rates of 81 per million in 2010 and 95 per million in 2013.23, 48 Our overall ICD implant rate in 2016 is second only to Australia in the Asia‐Pacific region.22, 49 However, our ICD implant rates (excluding CRT‐D) are just below the mean of European Society of Cardiology (ESC) member countries.50 The implant rates are comparable to the United Kingdom, but lag significantly behind countries with similar gross domestic product and healthcare spending such as Italy and Finland. Our overall CRT implant rate is again second only to Australia in the Asia‐Pacific region, but lies only in the second quartile of implant rates of ESC member countries. The CRT‐P implant rates are on par with the mean ESC implant rate, but our CRT‐D implant rate is less than half that of the mean ESC implant rate.22, 49, 50
There is significant regional variation in implant practice across NZ. This is likely to be influenced by physician preference and resource constraints at a local and regional level.
5. LIMITATIONS
This study is a descriptive analysis of the data within the DEVICE Registry. As a number of implant sites joined and left the registry during the period of analysis, the registry does not contain data of all patients in NZ receiving an ICD or CRT during this study period. Despite this, we believe this to be a representative cohort, as the age, gender, and ethnicity distribution is very similar compared to patients receiving an ICD who are identified from the National Hospitalisation Dataset, which collects all public hospital admissions in NZ using International Statistical Classification of Diseases and Related Health Problems, Tenth Revision, Australian Modification (ICD10‐AM) coding (Appendix S1). While there is no routine audit of data accuracy of the registry at present, our recent validation analysis of the registry data quality in 2016 (when all implant sites participated in the registry) demonstrated a good capture rate and excellent agreement of basic demographic and procedural data items with the national dataset. However, the implant volumes and rates for 2016 are likely to be slightly underestimated as only 94.6% of DEVICE‐PPM forms and 87.7% of DEVICE ICD forms were completed in 2016.
At present, NYHA class and LVEF are only recorded in the cohort of ICD patients with a previous history of clinical heart failure, which is less than 40% in those receiving a secondary prevention ICD and only 60% of all new ICD implants. The ICD indications currently include syncope, presyncope and nonsustained ventricular tachycardia in both primary prevention and secondary prevention indications, therefore some patients may have been misclassified. The ANZACS‐QI registry is currently being updated to address these limitations.
6. CONCLUSION
In contemporary NZ practice three‐quarters of ICD implants were new implants, of which half were for primary prevention indications. The majority of patients receiving primary prevention and secondary prevention ICD met current international guideline indications. Our relatively low ratio of primary to secondary prevention ICD implants internationally suggests a conservative patient selection for primary prevention ICD. Compared to new primary prevention CRT‐D implants, patients who received a new CRT‐P were older and more likely to be female. Of patients receiving a replacement ICD nearly half had received appropriate device therapy over the battery life of the device. There was significant regional variation in ICD and CRT implant rates, ratio of primary prevention ICD implants, and selection of CRT modality.
CONFLICT OF INTERESTS
The authors declare no conflict of interests for this article.
Supporting information
ACKNOWLEDGEMENTS
ANZACS‐QI programme implementation, coordination and analysis: The ANZACS‐QI software was developed and supported by Enigma Solutions. Programme implementation is coordinated by the National Institute for Health Innovation (NIHI) at the University of Auckland. The ANZACS‐QI programme is funded by the NZ Ministry of Health. The authors receive support from the Health Research Council and Middlemore Cardiac Trust.
ANZACS‐QI Governance group: A. Kerr (chair), C. Nunn, D. Boddington, G. Sutcliffe, G. Devlin, H. White, J. Edmond, J. Tisch, S. Riddle, K. Marshall, M. Lund, M. Williams (deputy chair), N. Fisher, T. Scott. ANZACS‐QI Project management: K. Sutherland (Project Manager), C. Flynn (Northern coordinator), M. Rhodes (Southern coordinator), A. Rattray (Research Assistant). Data analysis: M. Lee, R. Chan, Y. Jiang. Data management: M. Jenkins, J. Faatui. We acknowledge all the NZ cardiologists, physicians, nursing staff, and physiologists who have supported and contributed to ANZACS‐QI. ANZACS‐QI hospital cardiac physiologists: Ascot Angiography: M. Lindesay, J. Money, R. Singh, R. Chatburn, R. Kelly, J. Salmon, A. Visser. Intra Healthcare: J. Youbard. Auckland City Hospital (Bay of Islands, Kaitaia, Whangarei, Dargaville): S. Brett, S. Khan, R. Metrick, P. Harris, S. Sinclair, B. Jolly, A. Cheriyan, F. Riddell, H. Finnemore, G. Orsbourn, C. Williams, K. Turner, K. Maas, J. Donald, L. Kitipa, L. Cooper, M. Fowler. Middlemore Hospital: T. Brown, S. Takau, C. Chang, F. McLean, C. Smith. Waikato Hospital (Rotorua, Gisborne, Taranaki, Taumarunui, Te Kuiti, Tokoroa, Taupo, Thames): R. Allen, K. Timmins, K. Coley, P. Jones, N. Anthony‐Pudumai, V. Day, V. Stuit, L. Simms, C. Whiteley, A. Wilson. Midland CVS: P. Jones. Tauranga Hospital (Whakatane): K. Hunter, S. Tait, P. Bishop, M. Cookley, T. Cumming, J. Goodson. Christchurch Hospital: O. Thacker. Dunedin Hospital: E. Guglietta, V. Milmine. Hawkes Bay Hospital: J.Cotton. Southland Hospital: L. Wilson. Nelson Hospital: T. Lawson. Palmerston North Hospital: J. White. North Shore Hospital: R. Breakwell, K. Searby, D. Slipper, M. Lipski, A. Sohil, K. Todd, C. Tilsley, K. Harris, A. Clayton, L. Moloney. Wellington Hospital: B. Scott, D. Wylie.
Foo FS, Lee M, Looi K‐L, et al; on behalf of the ANZACS‐QI investigators . Implantable cardioverter defibrillator and cardiac resynchronization therapy use in New Zealand (ANZACS‐QI 33). J Arrhythmia. 2020;36:153–163. 10.1002/joa3.12244
Contributor Information
Fang Shawn Foo, Email: shawnfoo@icloud.com.
on behalf of the ANZACS‐QI investigators:
C. Nunn, G. Sutcliffe, G. Devlin, H. White, J. Edmond, J. Tisch, S. Riddle, K. Marshall, M. Lund, M. Williams, N. Fisher, T. Scott, K. Sutherland, C. Flynn, M. Rhodes, A. Rattray, R. Chan, Y. Jiang, M. Jenkins, J. Faatui, M. Lindesay, J. Money, R. Singh, R. Chatburn, R. Kelly, J. Salmon, A. Visser, J. Youbard, S. Brett, S. Khan, R. Metrick, P. Harris, S. Sinclair, B. Jolly, A. Cheriyan, F. Riddell, H. Finnemore, G. Orsbourn, C. Williams, K. Turner, K. Maas, J. Donald, L. Kitipa, L. Cooper, M. Fowler, T. Brown, S. Takau, C. Chang, F. McLean, C. Smith, R. Allen, K. Timmins, K. Coley, P. Jones, N. Anthony‐Pudumai, V. Day, V. Stuit, L. Simms, C. Whiteley, A. Wilson, P. Jones, K. Hunter, S. Tait, P. Bishop, M. Cookley, T. Cumming, J. Goodson, O. Thacker, E. Guglietta, V. Milmine, J. Cotton, L. Wilson, T. Lawson, J. White, R. Breakwell, K. Searby, D. Slipper, M. Lipski, A. Sohil, K. Todd, C. Tilsley, K. Harris, A. Clayton, L. Moloney, B. Scott, and D. Wylie
REFERENCES
- 1. Ponikowski P, Voors AA, Anker SD,Bueno H, Cleland J, Coats A, et al. 2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure. Eur Heart J. 2016;37(27):2129–200. [DOI] [PubMed] [Google Scholar]
- 2. Buxton AE, Lee KL, Fisher JD, Josephson ME, Prystowsky EN, Hafley G. A randomized study of the prevention of sudden death in patients with coronary artery disease. Multicenter Unsustained Tachycardia Trial Investigators. N Engl J Med. 1999;341(25):1882–90. [DOI] [PubMed] [Google Scholar]
- 3. Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002;346(12):877–83. [DOI] [PubMed] [Google Scholar]
- 4. Kadish A, Dyer A, Daubert JP, Quigg R, Estes N, Anderson KP, et al. Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy. N Engl J Med. 2004;350(21):2151–8. [DOI] [PubMed] [Google Scholar]
- 5. Hohnloser SH, Kuck KH, Dorian P, Roberts RS, Hampton JR, Hatala R, et al. Prophylactic use of an implantable cardioverter‐defibrillator after acute myocardial infarction. N Engl J Med. 2004;351(24):2481–8. [DOI] [PubMed] [Google Scholar]
- 6. Bardy GH, Lee KL, Mark DB, Poole JE, Packer DL, Boineau R, et al. Amiodarone or an implantable cardioverter‐defibrillator for congestive heart failure. N Engl J Med. 2005;352(3):225–37. [DOI] [PubMed] [Google Scholar]
- 7. Strickberger SA, Hummel JD, Bartlett TG,Frumin HI, Schuger CD, Beau SL, et al. Amiodarone versus implantable cardioverter‐defibrillator:randomized trial in patients with nonischemic dilated cardiomyopathy and asymptomatic nonsustained ventricular tachycardia–AMIOVIRT. J Am Coll Cardiol. 2003;41(10):1707–12. [DOI] [PubMed] [Google Scholar]
- 8. Moss AJ, Hall WJ, Cannom DS,Daubert JP, Higgins SL, Klein H, et al. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. N Engl J Med. 1996;335(26):1933–40. [DOI] [PubMed] [Google Scholar]
- 9. Yancy CW, Jessup M, Bozkurt B, Butler J, Casey DE Jr, Drazner MH et al. 2013 ACCF/AHA Guideline for the management of heart failure. J Am Coll Cardiol. 2013;62(16):e147–239. [DOI] [PubMed] [Google Scholar]
- 10. Smith W. New Zealand primary implantable cardioverter defibrillator implantation and biventricular pacing guidelines. N Z Med J. 2010;123(1309):86–96. [PubMed] [Google Scholar]
- 11. Connolly SJ, Gent M, Roberts RS, Dorian P, Roy D, Sheldon RS, et al. Canadian implantable defibrillator study (CIDS): a randomized trial of the implantable cardioverter defibrillator against amiodarone. Circulation. 2000;101(11):1297–302. [DOI] [PubMed] [Google Scholar]
- 12. Kuck KH, Cappato R, Siebels J, Rüppel R. Randomized comparison of antiarrhythmic drug therapy with implantable defibrillators in patients resuscitated from cardiac arrest : the Cardiac Arrest Study Hamburg (CASH). Circulation. 2000;102(7):748–54. [DOI] [PubMed] [Google Scholar]
- 13. The Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators . A comparison of antiarrhythmic‐drug therapy with implantable defibrillators in patients resuscitated from near‐fatal ventricular arrhythmias. N Engl J Med. 1997;337(22):1576–84. [DOI] [PubMed] [Google Scholar]
- 14. Al‐Khatib SM, Stevenson WG, Ackerman MJ, Bryant WJ, Callans DJ, Curtis AB, et al. 2017 AHA/ACC/HRS guideline for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: Executive summary: A report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. Hear Rhythm. 2018;15:e190–252. [DOI] [PubMed] [Google Scholar]
- 15. Bristow MR, Saxon LA, Boehmer J, Krueger S, Kass DA, De Marco T, et al. Cardiac‐resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med. 2004;350(21):2140–50. [DOI] [PubMed] [Google Scholar]
- 16. Cleland J, Daubert J‐C, Erdmann E, Freemantle N, Gras D, Kappenberger L, et al. The effect of cardiac resynchronization on morbidity and mortality in heart failure. N Engl J Med. 2005;352(15):1539–49. [DOI] [PubMed] [Google Scholar]
- 17. Moss AJ, Hall WJ, Cannom DS, Klein H, Brown MW, Daubert JP, et al. Cardiac‐resynchronization therapy for the prevention of heart‐failure events. N Engl J Med. 2009;361(14):1329–38. [DOI] [PubMed] [Google Scholar]
- 18. Abraham WT, Fisher WG, Smith AL, Delurgio DB, Leon AR, Loh E, et al. Cardiac resynchronization in chronic heart failure. N Engl J Med. 2002;346(24):1845–53. [DOI] [PubMed] [Google Scholar]
- 19. Kerr A, Williams MJ, White H, Doughty R, Nunn C, Devlin G, et al. The all New Zealand acute coronary syndrome quality improvement programme: implementation, methodology and cohorts (ANZACS‐QI 9). N Z Med J. 2016;129(1439):23–36. [PubMed] [Google Scholar]
- 20. Larsen PD, Kerr AJ, Hood M, Harding SA, Hooks D, Heaven D, et al. Pacemaker use in New Zealand – data from the New Zealand implanted cardiac device registry (ANZACS‐QI 15). Heart Lung Circ. 2017;26(3):235–9. [DOI] [PubMed] [Google Scholar]
- 21. Foo FS, Lee M, Larsen P, Heaven D, Lever N, Sinclair S, et al. Completeness of ANZACS-QI Cardiac Implanted DEVICE Registry and agreement with national datasets: ANZACS-QI 30. N Z Med J. 2019;132(1500):40–9. [PubMed] [Google Scholar]
- 22. Mond HG, Crozier I. The Australian and New Zealand cardiac implantable electronic device survey: calendar year 2017. Heart Lung Circ. 2019;28(4):560–6. [DOI] [PubMed] [Google Scholar]
- 23. Wilson D, Harding SA, Melton I, Lever NA, Stiles MK, Boddington D, et al. Geographic, ethnic and socioeconomic factors influencing access to implantable cardioverter defibrillators (ICDs) in New Zealand. Heart Lung Circ. 2012;21(9):576–81. [DOI] [PubMed] [Google Scholar]
- 24. Looi K‐L, Sidhu K, Cooper L, Dawson L, Slipper D, Gavin A, et al. Gender differences in the use of primary prevention ICDs in New Zealand patients with heart failure. Heart Asia. 2018;10(1):e010985. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25. Johansen JB;on behalf of the Steering Committee . Danish Pacemaker and ICD Register Annual Report 2016 Danish Pacemaker and ICD Register‐Annual Report 2016 2 Preface, 2016.
- 26. Bogossian H, Hochadel M, Ince H, Spitzer SG, Eckardt L, Maier S, et al. Single chamber implantable cardioverter defibrillator compared to dual chamber implantable cardioverter defibrillator. Less is more. Data from the German Device Registry. EP Eur. 2018;20(Suppl. 1):i200–i200. [DOI] [PubMed] [Google Scholar]
- 27. Gadler F, Valzania C, Linde C. Current use of implantable electrical devices in Sweden: data from the Swedish pacemaker and implantable cardioverter‐defibrillator registry. Europace. 2015;17(1):69–77. [DOI] [PubMed] [Google Scholar]
- 28. Fernández Lozano I, Osca Asensi J, Alzueta Rodríguez J. Spanish Implantable Cardioverter‐defibrillator Registry. 14th Official Report of the Spanish Society of Cardiology Electrophysiology and Arrhythmias Section (2017). Rev Española Cardiol. 2018;71(12):1047–58. [DOI] [PubMed] [Google Scholar]
- 29. Lazarus A, Biondi N, Thébaut J‐F, Durand‐Zaleski I, Chauvin M. Implantable cardioverter‐defibrillators in France: practices and regional variability. Europace 2011;13:1568–73. [DOI] [PubMed] [Google Scholar]
- 30. Almehmadi F, Porta‐Sánchez A, Ha A, Fischer HD, Wang X, Austin PC, et al. Mortality implications of appropriate implantable cardioverter defibrillator therapy in secondary prevention patients: contrasting mortality in primary prevention patients from a prospective population‐based registry. J Am Heart Assoc. 2017;6 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31. Masoudi FA, Ponirakis A, de Lemos JA, Jollis JG, Kremers M, Messenger JC, et al. Trends in U.S. cardiovascular care. J Am Coll Cardiol. 2017;69(11):1427–50. [DOI] [PubMed] [Google Scholar]
- 32. Murgatroyd F, Linker N, Cunningham D, Cunningham M, Chadburn L, Gilbert S, et al. National AUDIT of Cardiac rhythm management devices 2013‐14. 2014;(April 2015):15–7.
- 33. Køber L, Thune JJ, Nielsen JC, Haarbo J, Videbæk L, Korup E, et al. Defibrillator implantation in patients with nonischemic systolic heart failure. N Engl J Med. 2016;375(13):1221–30. [DOI] [PubMed] [Google Scholar]
- 34. Killu AM, Grupper A, Friedman PA, Powell BD, Asirvatham SJ, Espinosa RE, et al. Predictors and outcomes of “super‐response” to cardiac resynchronization therapy. J Card Fail. 2014;20(6):379–86. [DOI] [PubMed] [Google Scholar]
- 35. Ghani A, Delnoy P, Adiyaman A, Ottervanger JP, Ramdat Misier AR, Smit J, et al. Predictors and long‐term outcome of super‐responders to cardiac resynchronization therapy. Clin Cardiol. 2017;40(5):292–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36. Hsu JC, Solomon SD, Bourgoun M, McNitt S, Goldenberg I, Klein H, et al. Predictors of super‐response to cardiac resynchronization therapy and associated improvement in clinical outcome. J Am Coll Cardiol. 2012;59(25):2366–73. [DOI] [PubMed] [Google Scholar]
- 37. Goldenberg I, Moss AJ, Hall WJ, Foster E, Goldberger JJ, Santucci P, et al. Predictors of response to cardiac resynchronization therapy in the multicenter automatic defibrillator implantation trial with cardiac resynchronization therapy (MADIT‐CRT). Circulation. 2011;124(14):1527–36. [DOI] [PubMed] [Google Scholar]
- 38. van Bommel RJ, Bax JJ, Abraham WT, Chung ES, Pires LA, Tavazzi L, et al. Characteristics of heart failure patients associated with good and poor response to cardiac resynchronization therapy: a PROSPECT (Predictors of Response to CRT) sub‐analysis. Eur Heart J. 2009;30(20):2470–7. [DOI] [PubMed] [Google Scholar]
- 39. Arshad A, Moss AJ, Foster E, Padeletti L, Barsheshet A, Goldenberg I, et al. Cardiac resynchronization therapy is more effective in women than in men. J Am Coll Cardiol. 2011;57(7):813–20. [DOI] [PubMed] [Google Scholar]
- 40. Morani G, Gasparini M, Zanon F, Casali E, Spotti A, Reggiani A, et al. Cardiac resynchronization therapy‐defibrillator improves long‐term survival compared with cardiac resynchronization therapy‐pacemaker in patients with a class IA indication for cardiac resynchronization therapy: data from the Contak Italian Registry. EP Eur. 2013;15(9):1273–9. [DOI] [PubMed] [Google Scholar]
- 41. Kutyifa V, Geller L, Bogyi P, Zima E, Aktas MK, Ozcan EE, et al. Effect of cardiac resynchronization therapy with implantable cardioverter defibrillator versus cardiac resynchronization therapy with pacemaker on mortality in heart failure patients: results of a high‐volume, single‐centre experience. Eur J Heart Fail. 2014;16(12):1323–30. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42. Leyva F, Zegard A, Okafor O, de Bono J, McNulty D, Ahmed A, et al. Survival after cardiac resynchronization therapy: results from 50 084 implantations. Europace. 2018;21(5):754. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43. Marijon E, Leclercq C, Narayanan K, Boveda S, Klug D, Lacaze‐Gadonneix J, et al. Causes‐of‐death analysis of patients with cardiac resynchronization therapy: an analysis of the CeRtiTuDe cohort study. Eur Heart J. 2015;36(41):2767–76. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44. Germano JJ, Reynolds M, Essebag V, Josephson ME. Frequency and causes of implantable cardioverter‐defibrillator therapies: is device therapy proarrhythmic? Am J Cardiol [Internet]. 2006;97(8):1255–61. [DOI] [PubMed] [Google Scholar]
- 45. Borne RT, Varosy PD, Masoudi FA. Implantable cardioverter‐defibrillator shocks: Epidemiology, outcomes, and therapeutic approaches. JAMA Intern Med [Internet]. 2013;173(10):859–65. [DOI] [PubMed] [Google Scholar]
- 46. Saxon LA, Hayes DL, Gilliam FR, Heidenreich PA, Day J, Seth M, et al. Long‐Term outcome After ICD and CRT implantation and influence of remote device follow‐up. Circulation. 2010;122(23):2359–67. [DOI] [PubMed] [Google Scholar]
- 47. Weeke P, Johansen JB, Jorgensen OD, Nielsen JC, Moller M, Videbaek R, et al. Mortality and appropriate and inappropriate therapy in patients with ischaemic heart disease and implanted cardioverter‐defibrillators for primary prevention: data from the Danish ICD Register. Europace. 2013;15(8):1150–7. [DOI] [PubMed] [Google Scholar]
- 48. Mond HG, Crozier I. The Australian and New Zealand cardiac pacemaker and implantable cardioverter‐defibrillator survey: calendar year 2013. Heart Lung Circ. 2015;24(3):291–7. [DOI] [PubMed] [Google Scholar]
- 49. Zhang S.The APHRS White Book: Fifth edition. Asia Pacific Heart Rhythm Society [Internet]. 2017;
- 50. Raatikainen M, Arnar DO, Merkely B,Nielsen JC, Hindricks G, Heidbuchel H, et al. A decade of information on the use of cardiac implantable electronic devices and interventional electrophysiological procedures in the European Society of Cardiology countries: 2017 report from the European Heart Rhythm Association. Europace. 2017;19(2):ii1–90. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials