Skip to main content
The Cochrane Database of Systematic Reviews logoLink to The Cochrane Database of Systematic Reviews
. 2001 Jan 22;2001(1):CD000500. doi: 10.1002/14651858.CD000500

Endotracheal intubation at birth for preventing morbidity and mortality in vigorous, meconium‐stained infants born at term

Henry L Halliday 1,, David G Sweet 2
Editor: Cochrane Neonatal Group
PMCID: PMC7032671  PMID: 10796213

Abstract

Background

On the basis of evidence from non‐randomised studies, it has been recommended that all babies born through thick meconium should have their tracheas intubated so that suctioning of their airways can be performed. The aim is to reduce the incidence and severity of meconium aspiration syndrome. However, for term babies who are vigorous at birth endotracheal intubation may be both difficult and unnecessary.

Objectives

To determine if endotracheal intubation and suction of the airways at birth in vigorous term meconium‐stained babies is more beneficial than routine resuscitation including aspiration of the oro‐pharynx.

Search methods

The search was made from Oxford Database of Perinatal Trials, Cochrane Controlled Trials Register (The Cochrane Library, Issue 3, 2002), MEDLINE from 1966 to September 2002, and information obtained from knowledgeable practising neonatologists.

Selection criteria

Randomised trials which compared a policy of routine vs no (or selective) use of endotracheal intubation and aspiration in the immediate management of vigorous term meconium‐stained babies at birth.

Data collection and analysis

Data regarding clinical outcomes including mortality, meconium aspiration syndrome, other respiratory conditions, pneumothorax, need for oxygen supplementation, stridor, convulsions and hypoxic‐ischaemic encephalopathy were abstracted and analysed using Revman 4.1.

Main results

Four randomised controlled trials of endotracheal intubation at birth in vigorous term meconium‐stained babies were identified. Meta‐analysis of these trials does not support routine use of endotracheal intubation at birth in vigorous meconium‐stained babies to reduce mortality, meconium aspiration syndrome, other respiratory symptoms or disorders, pneumothorax, oxygen need, stridor, HIE and convulsions. However, the event rates of many of these outcomes is low in the reported trials making reliable estimates of treatment effect impossible.

Authors' conclusions

Routine endotracheal intubation at birth in vigorous term meconium‐stained babies has not been shown to be superior to routine resuscitation including oro‐pharyngeal suction. This procedure cannot be recommended for vigorous infants until more research is available.

Keywords: Humans; Infant, Newborn; Intubation, Intratracheal; Meconium Aspiration Syndrome; Meconium Aspiration Syndrome/prevention & control; Randomized Controlled Trials as Topic; Suction

Plain language summary

Endotracheal intubation at birth for preventing morbidity and mortality in vigorous, meconium‐stained infants born at term

Meconium is the first stool of a newborn baby, greenish‐black in colour and rather sticky in consistency.  If a baby is distressed before birth meconium may be passed into the amniotic fluid and if the baby then gasps the meconium‐stained fluid may pass into the lungs.  Once in the lungs the meconium can make the baby ill by obstructing the airways and causing inflammation this is called meconium aspiration syndrome.  It is possible to reduce the amount of meconium getting into the lungs by sucking it from the baby’s throat and windpipe (trachea) soon after birth but it is not certain if this leads to overall benefit for the vigorous term newborn baby.  Furthermore, placing a tube in the windpipe (endotracheal intubation) of a vigorous term baby is not always easy and could cause harm.  Four studies enrolled 2844 term infants and randomly allocated them to intubation to clear the airways or routine resuscitation without intubation.  No benefit was found from routine intubation compared to routine resuscitation for vigorous term babies.  The outcomes reported included: meconium aspiration syndrome, lung air leaks, need for oxygen, noisy breathing (stridor) and fits but there were no significant differences between the two groups.  Routine endotracheal intubation of vigorous term babies born through meconium‐stained amniotic fluid cannot be recommended.  For non‐vigorous babies endotracheal intubation is probably indicated until more information becomes available.

Background

Three non‐randomised studies have suggested that careful aspiration of the airway at birth reduces both the incidence and severity of meconium aspiration syndrome (Gregory 1974; Ting 1975; Carson 1976). These authors have suggested that when thick meconium staining has occurred the obstetrician should suck out the mouth as the head crowns, using either a suction catheter or a bulb suction. Gregory et al found that 56% of meconium stained infants had meconium in the trachea, and in 10% there was meconium below the cords despite it being absent from the mouth or pharynx. Intubation of the tracheas of meconium stained babies at birth has been advocated by these authors as a means of preventing or ameliorating severe meconium aspiration syndrome.

Intubation of the trachea in an active term or post‐term baby with meconium staining may be difficult and in many cases unnecessary. Four randomised studies have examined the role of routine intubation and airway aspiration of meconium stained babies.

Objectives

The objective of this overview is to examine the relative benefits and adverse effects associated with routine intubation of the trachea in vigorous meconium stained term infants.

Methods

Criteria for considering studies for this review

Types of studies

Randomised controlled clinical trials comparing a policy of endotracheal intubation and airway suction at birth with routine resuscitation including oro‐pharyngeal aspiration in vigorous term meconium‐stained babies were considered for this review.

Types of participants

Full‐term babies with meconium staining but who were not obviously asphyxiated at birth.

Types of interventions

Infants were randomly allocated to receive endotracheal intubation and airway aspiration at birth or to have routine resuscitation as determined by the paediatrician in attendance.

Types of outcome measures

Clinical outcome measures included: mortality, meconium aspiration syndrome, respiratory symptoms (including other respiratory disorders), pneumothorax, need for oxygen, stridor, hypoxic‐ischaemic encephalopathy and convulsions.

Search methods for identification of studies

Randomised studies of endotracheal intubation and suction in meconium stained neonates were sought from the Oxford Database of Perinatal Trials, the Cochrane Controlled Trials Register (The Cochrane Library, Issue 3, 2002, MEDLINE (searched from 1966 to September 2002) using meconium aspiration and endotracheal intubation or airway suctioning with limits: randomised controlled trial, human and age 0‐1 month, and from information obtained from practising neonatologists.

Data collection and analysis

For each included trial information was sought regarding the method of randomisation, blinding, stratification and whether the trial was single or multicentered. Information on the trial participants included birthweight, gestational age, gender, presentation and antenatal complications. Information on clinical outcomes was analysed for mortality, meconium aspiration syndrome, respiratory symptoms (including other respiratory disorders), pneumothorax, need for oxygen, stridor, hypoxic‐ischaemic encephalopathy and convulsions. Meta‐analysis of the included trials was performed using Revman 4.1

Results

Description of studies

Linder 1988 included 572 meconium stained babies who met the following criteria: gestational age > 37 weeks, birthweight > 2500 g, normal vaginal delivery, one minute Apgar > 8 and breathing spontaneously before being handed over to the paediatrician. Suction of the baby's mouth and nose with a catheter was performed while the head was on the perineum. Half of the team of paediatricians who participated in the study were to intubate and suction all meconium stained babies during their attendance at birth whilst the other half was instructed to refrain from doing so. Randomisation of the paediatricians was based upon the alphabetic order of their names. All the paediatricians were skilled in neonatal resuscitation, having at least 3 years of paediatric experience. On the days when paediatricians not participating in the study were on duty, the babies born with meconium staining were routinely intubated and had airway aspiration. These babies were included in the intervention group. Aspiration of the upper and lower airways was performed by a paediatrician using a 2.5 or 3.0 mm oro‐tracheal tube. Suction was continued during tube removal, and if the tracheal aspirate continued to contain meconium the procedure was repeated until clear airways were established. Meconium aspiration was diagnosed if meconium staining of the amniotic fluid was accompanied by neonatal oxygen dependency and a consistent radiographic picture.

Daga 1994 examined the outcome of 49 babies born with thick meconium staining of the amniotic fluid. These were consecutively born infants who had passed meconium in utero and were not asphyxiated at birth. They were randomly allocated to either oro‐pharyngeal suction or combined oro‐pharyngeal and tracheal suction. All of the babies were admitted to a neonatal intensive care unit for observation.

Liu 1998 was designed to determine if intubation of the low risk term newborn born through thin meconium affects the incidence of respiratory symptoms. Exclusion criteria included moderate (particulate) or thick ("pea‐soup") meconium, fetal distress, clinical neonatal depression, prematurity (< 37 weeks), suspected intrauterine growth retardation, maternal drug abuse or maternal hypertensive disorders. Neonatal depression was defined as a hypotonic newborn who was not initiating adequate respiratory effort after 15 seconds of routine delivery room management. Non‐medical exclusion criteria included: the attending obstetrician requested that the newborn not be intubated, maternal refusal of consent or late arrival of the team. Eligible infants were randomised to either an intubation group or to a non‐intubation group. Infants in the intubation group were intubated with a 3.0 or 3.5 mm endotracheal tube and suctioned with a 6.0 or a 8.0 Fr suction catheter. Suction was set at 100 mmHg and was continued until clear, as tolerated. Saline lavage with sterile normal saline was initiated at the team's discretion. In these cases a minimum amount of 0.25‐0.50 mL was used as needed. Finally a meconium aspirator was placed on the endotracheal tube and suction applied as the tube was removed. Management of the non‐intubation group included: oronasopharyngeal suction with a bulb syringe and supplemental oxygen as clinically indicated. The outcome measurements were respiratory symptoms and the need for supplemental oxygen. 169 infants were enrolled in the study.

Wiswell 2000 included infants fulfilling the following criteria: 1) Gestation of 37 weeks or greater 2) Meconium presence in the amniotic fluid and 3) Apparent vigour immediately after birth (heart rate > 100, spontaneous respirations, reasonable tone). The degree of vigour was assessed within the first 10‐15 seconds after delivery. Meconium staining of the amniotic fluid could be of any consistency. Meconium aspiration syndrome was defined as respiratory distress with consistent radiographic findings and clinical signs that could not be otherwise explained. The obstetric policy was to suction the oro‐pharynx of each meconium stained neonate prior to delivery of the infant's shoulders or trunk. Prior to delivery subjects were randomised either to intubation and intracheal suctioning or to expectant management. Computer generated random numbers were used for assignment to these groups and group selection was determined by opening a sealed opaque envelope. When a neonate did not meet the criteria for apparent vigour the infant was excluded from the study and the randomisation assignment was discarded. A Neotech aspirator was used to suction the endotracheal tube using wall suction set at 80 to 120 mmHg negative pressure. Suction was applied continuously for 1‐5 seconds as the endotracheal tube was withdrawn. If meconium was suctioned from the trachea, the procedure was repeated until no further meconium stained fluid could be retrieved. Infants randomised to the expectant group had routine delivery room care. If following initial stabilisation and assessment these babies showed signs of respiratory distress the birth attendants could intubate and suction the airways if they felt it was clinically indicated. 2094 apparently vigorous infants were enrolled from the 12 participating centres.

Risk of bias in included studies

Linder 1988 ‐ Imperfect randomisation based upon the alphabetic order of the attending paediatrician's name. Note inclusion of babies who were born on days when participating paediatricians were not on duty in the intubation group.

Daga 1994 ‐ The method of randomisation is not stated. Description of the interventions is scanty.

Liu 1998 ‐ There was random allocation of the intervention but the method is not described in either the abstract (Liu, Pediatr Res 1998) or the full paper. 163 infants fulfilled the criteria for entry but were not randomised due to lack of consent, late arrival of the team or obstetrician request. The obstetricians and other staff were aware of the study but were unaware of the patient randomisation in the delivery room. The NICU team was aware of the randomisation. Informed consent was obtained prior to delivery. There may have been some blinding of outcome assessment, but this is difficult to determine.

Wiswell 2000 ‐ The intervention was randomly allocated prior to birth by opening opaque sealed envelopes. Outcome data were collected on a standardised form which was sent to a central unit for entry into a database. All investigators remained blinded until completion of the trial.

Effects of interventions

Linder 1988 ‐ six babies in the airway aspiration group had respiratory complications, meconium aspiration in four, and stridor in two. There were no respiratory complications in the conservatively managed group and no deaths in either group.

Daga 1994 ‐ one neonate who had received oro‐pharyngeal and tracheal suction died. Three babies developed pneumothorax requiring intercostal drainage; one in the tracheal suction group and two in the oro‐pharyngeal suction group. Four babies developed convulsions, three of them in the tracheal suction group, one of whom developed hypoxic‐ischaemic encephalopathy.

Liu 1998 ‐ 2 of the 77 infants in the intubation group developed respiratory symptoms and one of these needed oxygen, compared to 1 of 92 infants in the non‐intubation group who developed symptoms but did not need oxygen. The intubation group had significantly lower 1 minute Apgar scores but 5 minute Apgar scores were similar. There was no reported airway morbidity associated with intubation.

Wiswell 2000 ‐ 34 of 1051 infants in the intubation group developed meconium aspiration syndrome compared to 28 of 1043 in the expectant management group. 40 of 1051 babies in the intubated group compared to 47 of 1043 of the expectant group developed "other" respiratory disorders. Five deaths occurred: 2 in the intubated and 3 in the expectant group. 17 of 1051 infants in the intubated group were not intubated for several reasons, most commonly excessively difficult intubation. 64 of 1043 babies in the expectant group were intubated after the initial assessment period because they developed clinical signs which included respiratory distress, poor respiratory effort and evidence of meconium blocking the airway. Of the 1098 successfully intubated infants (1034 from the intubated group and 64 from the expectant group), 42 (3.8%) had a total of 51 complications of the procedure which included bradycardia, laryngospasm and hoarseness but most were transient lasting 15‐60 seconds.

Meta‐analysis of these four studies showed the following:

  • Mortality ‐ there was no evidence that endotracheal intubation at birth had an effect on mortality (typical relative risk, 1.73, 95% CI 0.37, 8.1; number of studies 4, number of infants 2884), but the number of deaths reported was very low (4 and 2 respectively).

  • Meconium aspiration syndrome ‐ there was no evidence that endotracheal intubation reduced this outcome (typical relative risk, 1.29, 95% CI 0.80, 2.08; n=4 and 2884 respectively), but the total number of observed cases was relatively low (37 and 28 respectively).

  • Other respiratory symptoms or disorders ‐ there was no evidence that intubation affected the incidence of this outcome (typical relative risk 0.87, 95% CI 0.58, 1.31; n= 2 and 2763).

  • Pneumothorax ‐ no evidence of an effect of intubation on this outcome (typical relative risk 0.87, 95% CI 0.16, 4.92; n=2 and 621), but only four cases of pneumothorax occurred (2 and 2 respectively).

  • Oxygen need ‐ no evidence of an effect of intubation on this outcome (typical relative risk 1.49, 95% CI 0.86, 2.60; n=3 and 790).

  • Stridor ‐ there was no evidence of effect on stridor, but there were too few cases of stridor (2 and 0 respectively) in these trials to provide a reliable estimate of treatment effect (relative risk 4.29, 95% CI 0.21, 88.9; n=1 and 572).

  • Convulsions ‐ there was no evidence of effect on convulsions but there were too few cases of convulsions in these trials to provide a reliable estimate of treatment effect (relative risk 2.65, 95% CI 0.30, 23.8; n=1 and 49)

  • Hypoxic‐ischaemic encephalopathy ‐ there was no evidence of effect on hypoxic‐ischaemic encephalopathy but there were too few cases of hypoxic‐ischaemic encephalopathy in these trials to provide a reliable estimate of treatment effect (relative risk 2.67, 95% CI 0.11, 62.4; n=1 and 49).

Discussion

A number of previous non‐randomised studies have suggested that aspiration of the upper and lower airways of babies with significant meconium staining is associated with an improved outcome. Babies in these studies included those who were very depressed at birth and those who were relatively vigorous. Most neonatology text books continue to recommend aspiration of the airways, both upper and lower in cases of thick or particulate meconium staining of the amniotic fluid.

Four randomised studies have addressed the problem of endotracheal intubation of vigorous meconium stained infants born at term. Although there are methodological problems with randomisation in some of these studies there is no evidence that endotracheal intubation and aspiration of the airways in non‐asphyxiated meconium‐stained babies is beneficial. However it is likely that routine aspiration of the upper airways is beneficial and should not be discarded. For depressed or non‐vigorous newborns endotracheal intubation and suctioning should probably still be performed in infants born through meconium stained amniotic fluid, until further research is available.

Authors' conclusions

Implications for practice.

Until further evidence is available routine intubation of vigorous term meconium stained babies to aspirate the lungs should be abandoned. Suctioning of the oro‐pharynx may be beneficial but endotracheal intubation should be reserved for depressed or non‐vigorous infants or those who develop signs of respiratory distress following initial assessment.

Implications for research.

Further research is needed to define a group of term babies with meconium staining who might benefit from intubation and airway aspiration. Future studies should include unequivocal endpoints such as mortality and independently assessed radiograph reporting. It is clear that a study examining mortality as an outcome would need to be extremely large and with present knowledge might not be justifiable.

What's new

Date Event Description
23 October 2008 Amended Converted to new review format.

History

Review first published: Issue 1, 2000

Date Event Description
31 October 2002 New search has been performed The review updates the existing review of "Endotracheal intubation at birth for preventing morbidity and mortality in vigorous, meconium‐stained infants born at term" published in The Cochrane Library, Issue 1, 2001. 
 
 The search for eligible trials was updated to October 2002 and no new trials were found. The conclusions from the previous review remain unchanged.
26 October 2000 New citation required but conclusions have not changed Substantive amendment

Acknowledgements

None

Data and analyses

Comparison 1. Routine tracheal intubation/suction vs control.

Outcome or subgroup title No. of studies No. of participants Statistical method Effect size
1 Mortality 4 2884 Risk Ratio (M‐H, Fixed, 95% CI) 1.73 [0.37, 8.12]
2 Pneumothorax 2 621 Risk Ratio (M‐H, Fixed, 95% CI) 0.87 [0.16, 4.92]
3 Oxygen need 3 790 Risk Ratio (M‐H, Fixed, 95% CI) 1.49 [0.86, 2.60]
4 Meconium aspiration syndrome 4 2884 Risk Ratio (M‐H, Fixed, 95% CI) 1.29 [0.80, 2.08]
5 Stridor 1 572 Risk Ratio (M‐H, Fixed, 95% CI) 4.29 [0.21, 88.92]
6 Convulsions 1 49 Risk Ratio (M‐H, Fixed, 95% CI) 2.65 [0.30, 23.77]
7 Hypoxic ischemic encephalopathy 1 49 Risk Ratio (M‐H, Fixed, 95% CI) 2.67 [0.11, 62.42]
8 Respiratory symptoms 2 2263 Risk Ratio (M‐H, Fixed, 95% CI) 0.87 [0.58, 1.31]

1.1. Analysis.

1.1

Comparison 1 Routine tracheal intubation/suction vs control, Outcome 1 Mortality.

1.2. Analysis.

1.2

Comparison 1 Routine tracheal intubation/suction vs control, Outcome 2 Pneumothorax.

1.3. Analysis.

1.3

Comparison 1 Routine tracheal intubation/suction vs control, Outcome 3 Oxygen need.

1.4. Analysis.

1.4

Comparison 1 Routine tracheal intubation/suction vs control, Outcome 4 Meconium aspiration syndrome.

1.5. Analysis.

1.5

Comparison 1 Routine tracheal intubation/suction vs control, Outcome 5 Stridor.

1.6. Analysis.

1.6

Comparison 1 Routine tracheal intubation/suction vs control, Outcome 6 Convulsions.

1.7. Analysis.

1.7

Comparison 1 Routine tracheal intubation/suction vs control, Outcome 7 Hypoxic ischemic encephalopathy.

1.8. Analysis.

1.8

Comparison 1 Routine tracheal intubation/suction vs control, Outcome 8 Respiratory symptoms.

Characteristics of studies

Characteristics of included studies [ordered by study ID]

Daga 1994.

Methods Random allocation, method not described. Blinding of randomisation : can't tell. Blinding of intervention : no. Complete follow‐up : yes. Blinding of outcome measurement : probably no.
Participants 49 consecutively born infants who passed thick meconium in utero and were not asphyxiated at birth were included. The study was conducted between February 1991 and September 1991 when the total number of births during this period was 1322.
Interventions The treatment group had oropharyngeal suction combined with tracheal suction whereas the control group had only oropharyngeal suction. All babies were admitted to the neonatal intensive care unit for observation.
Outcomes Mortality, pneumothorax, convulsions, HIE and duration of oxygen administration.
Notes The figures in the summary do not tally with those in the text or table. Results in the summary have been ignored.
Risk of bias
Bias Authors' judgement Support for judgement
Allocation concealment? Unclear risk B ‐ Unclear

Linder 1988.

Methods Randomised controlled trial but some non‐randomised babies were included in intervention group. Blinding of randomisation : no. Blinding of intervention : no. Complete follow‐up : yes. Blinding of outcome measurement : probably no.
Participants 572 meconium‐stained infants born between June 1984 and December 1986 who met the following criteria: gestational age > 37 weeks, birthweight > 2500 g, normal vaginal delivery, 1 minute Apgar score > 8, and breathing spontaneously before being handed over to the paediatrician were included.
Interventions Both groups had suction of the infant's mouth and nose with de Lee catheter while the head was on the perineum. The treatment group also had endotracheal intubation using a 2.5 ‐ 3.0 mm orotracheal tube for aspiration of the upper and lower airways. Suction was continued during tube removal. If tracheal aspirate continued to contain meconium the procedure was repeated until clear airways were established. The control group did not have endotracheal intubation.
Outcomes Mortality, meconium aspiration syndrome, pneumothorax, need for oxygen supplementation, stridor
Notes On days when paediatricians not participating in the study were on duty, babies born with meconium staining were managed with endotracheal intubation and aspiration and were thus included in the treatment group.
Risk of bias
Bias Authors' judgement Support for judgement
Allocation concealment? High risk C ‐ Inadequate

Liu 1998.

Methods Random allocation, method not described. Blinding of randomisation: can't tell. Blinding of intervention: no. Complete follow‐up: yes. Blinding of outcome measurements: probably no.
Participants 169 infants of low‐risk born through thin meconium. Exclusion criteria included moderate or thick meconium staining, fetal distress, neonatal depression or prematurity. There were 8967 births during the study period and 7.9% were born through meconium. Thin meconium was noted in 50% of these. 163 infants were medically eligible but could not be randomised due to lack of consent, late arrival of the team or obstetrician request.
Interventions Endotracheal intubation and suctioning of the airways with a suction catheter. Some infants had saline lavage. A meconium aspirator was used to apply suction as the endotracheal tube was removed. The control group did not have endotracheal intubation, but received oronasopharyngeal with a bulb syringe.
Outcomes Outcome measures were the presence of respiratory symptoms after birth and the need for supplemental oxygen. One and 5 minute Apgar scores were also recorded.
Notes  
Risk of bias
Bias Authors' judgement Support for judgement
Allocation concealment? Unclear risk B ‐ Unclear

Wiswell 2000.

Methods Random allocation of the intervention just prior to birth by opening opaque sealed envelopes. Blinding of randomisation: yes. Blinding of intervention: no. Complete follow‐up: yes. Blinding of outcome measurements: probably no.
Participants 2094 apparently vigorous infants were enrolled from 12 participating centres. Inclusion criteria included: gestational age 37 weeks or greater, birth through meconium stained amniotic fluid of any consistency and "vigour" immediately after birth (heart rate > 100, spontaneous respirations, reasonable tone).
Interventions The intervention group had endotracheal intubation and suction of the airways whereas the control group had expectant management. 64/1043 (6.1%) of infants in the expectant management group needed endotracheal intubation between 1 and 7 minutes of age because of respiratory distress, poor respiratory effort or meconium blocking the airway.
Outcomes Meconium aspiration syndrome, "other" respiratory disorders (transient tachypnoea, delayed transition, pneumonia etc.). Complications of intubation were also reported.
Notes  
Risk of bias
Bias Authors' judgement Support for judgement
Allocation concealment? Low risk A ‐ Adequate

Declarations of interest

None

Edited (no change to conclusions)

References

References to studies included in this review

Daga 1994 {published data only}

  1. Daga SR, Dave K, Mehta V, Pai V. Tracheal suction in meconium stained infants: a randomized controlled study. Journal of Tropical Pediatrics 1994;40:198‐200. [DOI] [PubMed] [Google Scholar]

Linder 1988 {published data only}

  1. Linder N, Aranda JV, Tsur M, Matoth I, Yatsiv I, Mandelberg H, Rottem M, Feigenbaum D, Ezra Y, Tamir I. Need for endotracheal intubation and suction in meconium‐stained neonates. Journal of Pediatrics 1988;112:613‐615. [DOI] [PubMed] [Google Scholar]

Liu 1998 {published data only}

  1. Liu WF. Delivery room intubation of thin meconium in the low‐risk newborn: a clinical trial [abstract]. Pediatric Research 1998;43:182A. [DOI] [PubMed] [Google Scholar]
  2. Liu WF, Harrington T. The need for delivery room intubation of thin meconium in the low‐risk newborn: a clinical trial. American Journal of Perinatology 1998;15:675‐82. [DOI] [PubMed] [Google Scholar]

Wiswell 2000 {published data only}

  1. Wiswell TE, Gannon CM, Jacob J, et al. Delivery room management of the apparently vigorous meconium‐stained neonate: results of the multicenter, international collaborative trial. Pediatrics 2000; Vol. 105:1‐7. [DOI] [PubMed]

Additional references

Carson 1976

  1. Carson BS, Losey RW, Bowes WA, Simmons MA. Combined obstetric and pediatric approach to prevent meconium aspiration syndrome. American Journal of Obstetrics and Gynecology 1976;126:712‐5. [DOI] [PubMed] [Google Scholar]

Gregory 1974

  1. Gregory GA, Gooding CA, Phibbs RH, Tooley WH. Meconium aspiration in infants: a prospective study. Journal of Pediatrics 1974;85:848‐52. [DOI] [PubMed] [Google Scholar]

Ting 1975

  1. Ting P, Brady JP. Tracheal suction in meconium aspiration. Obstetrics and Gynecology 1975;122:767‐71. [DOI] [PubMed] [Google Scholar]

References to other published versions of this review

Halliday 2000

  1. Halliday HL. Endotracheal intubation at birth for prevention of mortality and morbidity in vigorous, meconium‐stained infants born at term. Cochrane Database of Systematic Reviews 2000, Issue 1. [DOI: 10.1002/14651858.CD000500] [DOI] [PMC free article] [PubMed] [Google Scholar]

Halliday 2001

  1. Halliday HL. Endotracheal intubation at birth for prevention of mortality and morbidity in vigorous, meconium‐stained infants born at term. Cochrane Database of Systematic Reviews 2001, Issue 1. [DOI: 10.1002/14651858.CD000500] [DOI] [PubMed] [Google Scholar]

Articles from The Cochrane Database of Systematic Reviews are provided here courtesy of Wiley

RESOURCES