Abstract
This study documents results of SARS-CoV-2 polymerase chain reaction (PCR) testing of environmental surfaces and personal protective equipment surrounding 3 COVID-19 patients in isolation rooms in a Singapore hospital.
Coronaviruses have been implicated in nosocomial outbreaks1 with environmental contamination as a route of transmission.2 Similarly, nosocomial transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been reported.3 However, the mode of transmission and extent of environmental contamination are unknown.
Methods
From January 24 to February 4, 2020, 3 patients at the dedicated SARS-CoV-2 outbreak center in Singapore in airborne infection isolation rooms (12 air exchanges per hour) with anterooms and bathrooms had surface environmental samples taken at 26 sites. Personal protective equipment (PPE) samples from study physicians exiting the patient rooms also were collected. Sterile premoistened swabs were used.
Air sampling was done on 2 days using SKC Universal pumps (with 37-mm filter cassettes and 0.3-μm polytetrafluoroethylene filters for 4 hours at 5 L/min) in the room and anteroom and a Sartorius MD8 microbiological sampler (with gelatin membrane filter for 15 minutes at 6 m3/h) outside the room (eFigure in the Supplement).
Specific real-time reverse transcriptase–polymerase chain reaction (RT-PCR) targeting RNA-dependent RNA polymerase and E genes4 was used to detect the presence of SARS-CoV-2 (see detailed methods in the eAppendix in the Supplement). Cycle threshold values, ie, number of cycles required for the fluorescent signal to cross the threshold in RT-PCR, quantified viral load, with lower values indicating higher viral load.
Samples were collected on 5 days over a 2-week period. One patient’s room was sampled before routine cleaning and 2 patients’ rooms after routine cleaning. Twice-daily cleaning of high-touch areas was done using 5000 ppm of sodium dichloroisocyanurate. The floor was cleaned daily using 1000 ppm of sodium dichloroisocyanurate.
Clinical data (symptoms, day of illness, and RT-PCR results) and timing of cleaning were collected and correlated with sampling results. Percentage positivity was calculated for rooms with positive environmental swabs. Institutional review board approval and written informed consent were obtained as part of a larger multicenter study.
Results
Patient A’s room was sampled on days 4 and 10 of illness while the patient was still symptomatic, after routine cleaning. All samples were negative. Patient B was symptomatic on day 8 and asymptomatic on day 11 of illness; samples taken on these 2 days after routine cleaning were negative (Table 1).
Table 1. Sampling Time Points in Relation to Patient Illness and Clinical Cycle Threshold Values.
Patient | Days of illness when samples were collected | Presence of symptoms during sampling | Symptoms | Disease severitya | Before/after routine cleaning | Cycle threshold value from clinical samplesb |
---|---|---|---|---|---|---|
A | 4, 10 | Yes, both days | Cough, fever, shortness of breath | Moderate | After | 31.31 (day 3); 35.33 (day 9) |
B | 8, 11 | Yes on day 8; asymptomatic on day 11 | Cough, fever, sputum production | Moderate | After | 32.22 (day 8); not detected (day 11) |
C | 5 | Yes | Cough | Mild | Before | 25.69 (day 4) |
Disease severity was considered moderate if there was lung involvement (opacities on chest radiograph) and severe if patient required supplemental oxygen therapy.
Clinical samples were either nasopharyngeal swabs or sputum samples if patient could produce sputum. The most recent result prior to the environmental sampling was recorded. Cycle threshold refers to the number of cycles required for the fluorescent signal to cross the threshold in reverse transcriptase–polymerase chain reaction; a lower cycle threshold value indicates a higher viral load.
Patient C, whose samples were collected before routine cleaning, had positive results, with 13 (87%) of 15 room sites (including air outlet fans) and 3 (60%) of 5 toilet sites (toilet bowl, sink, and door handle) returning positive results (Table 2). Anteroom and corridor samples were negative. Patient C had upper respiratory tract involvement with no pneumonia and had 2 positive stool samples for SARS-CoV-2 on RT-PCR despite not having diarrhea.
Table 2. Environmental and PPE Sites Sampled and Corresponding RT-PCR Results.
Sitesa | Positive samples (patient C; before routine cleaning)b | Cycle threshold valuec |
---|---|---|
Environmental sitesd | ||
Patient’s room | ||
1. Cardiac table, including handle | 1/1 | 35.44 |
2. Entire length of bed rail | 1/1 | 37.95 |
3. Control panel on bed | 0/1 | |
4. Call bell attached to bed | 0/1 | |
5. Locker with hand slot | 1/1 | 36.21 |
6. Chair | 1/1 | 37.07 |
7. Light switches behind bed | 1/1 | 37.54 |
8. Stethoscope | 1/1 | 38.24 |
9. Sink, external rim | 1/1 | 35.54 |
10. Sink, internal bowl | 1/1 | 36.79 |
11. Floor | 1/1 | 30.64 |
12. Glass window in room | 1/1 | 35.79 |
13. Glass door interior | 1/1 | 35.71 |
14. PPE storage area over sink | 1/1 | 34.89 |
15. Air outlet fan | 2/3 | 32.96, 37.94 |
Toilet area | ||
16. Door handle | 1/1 | 35.83 |
17. Toilet bowl, surface | 1/1 | 37.75 |
18. Hand rail | 0/1 | |
19. Sink, external rim | 0/1 | |
20. Sink, internal bowl | 1/1 | 37.11 |
Anteroom | ||
21. Sink, external rim | 0/1 | |
22. Sink, internal bowl | 0/1 | |
23. Floor | 0/1 | |
24. Glass door, room side | 0/1 | |
25. Glass door, corridor side | 0/1 | |
Corridor outside room | ||
26. Floor | 0/1 | |
Total, No. (%) | 17/28 (61) | |
Staff PPE sites | ||
Upper front part of gown | 0/2 | |
Lower front part of gown | 0/2 | |
Front surface of face visor mask | 0/2 | |
Front surface of N95 mask | 0/2 | |
Surface of front of shoes | 1/2 | 38.96 |
Abbreviations: RT-PCR, reverse transcriptase–polymerase chain reaction; PPE, personal protective equipment.
Numbering of environmental sites corresponds to the numbering in the eFigure in the Supplement.
Results are shown as number of positive samples/number of total samples. All samples taken from patients A and B after routine cleaning were negative and not included in this table.
Cycle threshold refers to the number of cycles required for the fluorescent signal to cross the threshold in RT-PCR; a lower cycle threshold value indicates a higher viral load.
One swab was taken from each site except the air outlet fan, from which 3 swabs were taken.
Patient C had greater viral shedding, with a cycle threshold value of 25.69 in nasopharyngeal samples compared with 31.31 and 35.33 in patients A and B (Table 1).
Only 1 PPE swab, from the surface of a shoe front, was positive. All other PPE swabs were negative. All air samples were negative.
Discussion
There was extensive environmental contamination by 1 SARS-CoV-2 patient with mild upper respiratory tract involvement. Toilet bowl and sink samples were positive, suggesting that viral shedding in stool5 could be a potential route of transmission. Postcleaning samples were negative, suggesting that current decontamination measures are sufficient.
Air samples were negative despite the extent of environmental contamination. Swabs taken from the air exhaust outlets tested positive, suggesting that small virus-laden droplets may be displaced by airflows and deposited on equipment such as vents. The positive PPE sample was unsurprising because shoe covers are not part of PPE recommendations. The risk of transmission from contaminated footwear is likely low, as evidenced by negative results in the anteroom and clean corridor.
This study has several limitations. First, viral culture was not done to demonstrate viability. Second, due to operational limitations during an outbreak, methodology was inconsistent and sample size was small. Third, the volume of air sampled represents only a small fraction of total volume, and air exchanges in the room would have diluted the presence of SARS-CoV-2 in the air. Further studies are required to confirm these preliminary results.
Significant environmental contamination by patients with SARS-CoV-2 through respiratory droplets and fecal shedding suggests the environment as a potential medium of transmission and supports the need for strict adherence to environmental and hand hygiene.
Section Editor: Jody W. Zylke, MD, Deputy Editor.
References
- 1.Chowell G, Abdirizak F, Lee S, et al. Transmission characteristics of MERS and SARS in the healthcare setting: a comparative study. BMC Med. 2015;13:210. doi: 10.1186/s12916-015-0450-0 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Bin SY, Heo JY, Song MS, et al. Environmental contamination and viral shedding in MERS patients during MERS-CoV outbreak in South Korea. Clin Infect Dis. 2016;62(6):755-760. doi: 10.1093/cid/civ1020 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Wang D, Hu B, Hu C, et al. Clinical characteristics of 138 hospitalized patients with 2019 novel coronavirus-infected pneumonia in Wuhan, China. JAMA. Published online February 7, 2020. doi: 10.1001/jama.2020.1585 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Corman VM, Landt O, Kaiser M, et al. Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR. Euro Surveill. 2020;25(3). doi: 10.2807/1560-7917.ES.2020.25.3.2000045 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Young B, Ong SWX, Kalimuddin S, et al. . Epidemiologic features and clinical course of patients infected with SARS-CoV-2 in Singapore. JAMA. Published online March 3, 2020. doi: 10.1001/jama.2020.3204 [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.