Abstract
Ultrasound (US) has been found to rejuvenate and invigorate the hair follicles, increase the size of hair shafts, and promote new hair growth. Our present study found that dual-frequency US-mediated microbubble (MB) cavitation significantly enhanced minoxidil (Mx) delivery in both in vitro and in vivo models, while increasing the hair growth efficacy compared to single-frequency US sonication. The in vitro experiments showed that cavitation activity was enhanced more significantly during dual-frequency sonication than single-frequency sonication in higher concentration of MBs. The pigskin penetration depth in the group in which dual-frequency US was combined with MBs was 1.54 and 2.86 times greater than for single-frequency US combined with MBs and in the control group, respectively; the corresponding increases in the release rate of Mx at 18 hours in in vitro Franz-diffusion-cell experiments were 24.9% and 43.7%. During 21 days of treatment in C57BL/6J mice experiments, the growth rate at day 11 in the group in which dual-frequency US was combined with MBs increased by 2.07 times compared to single-frequency US combined with MBs. These results indicate that dual-frequency US-mediated MB cavitation can significantly increase both skin permeability and transdermal drug delivery. At the same US power density, hair growth was greater in the group with dual-frequency US plus MBs than in the group with single-frequency US plus MBs, without damaging the skin in mice.
Subject terms: Biophysics, Medical research
Introduction
Pressure waves generated by ultrasound (US) have been employed to enhance transdermal drug delivery (TDD) for many years1. In 2004, US at 20–100 kHz was approved by the United States FDA for the transdermal delivery of the local anesthetic lidocaine2. The shock waves contributing to the sonophoresis induced by US were hypothesized to structurally modify lipids of the stratum corneum to produce diffusion channels that allowed transdermal delivery3–5. The thermal effects of US also positively influence the drug diffusion coefficient and skin permeability coefficient, but might result in heating damage when administering thermally unstable transdermal drugs6,7.
US has recently been demonstrated to improve skin permeability and reduce thermal effects8. The most important mechanism for skin permeability enhancement induced by US is acoustic cavitation9. Inertial cavitation mediated by US has been previously shown to mediate much greater permeability enhancement of the skin surface to enhance the transdermal delivery of drugs and vaccines than stable cavitation10–13. A previous study demonstrated that US-assisted vaccine delivery in the presence of sub-micron cavitation nuclei resulted higher specific antibody levels compared to other transdermal methods14. Our previous studies demonstrated that combined treatment with US using optimal parameters and optimal conditions (size or concentration) of microbubbles (MBs) can increase skin permeability so as to enhance drug delivery without increasing temperatures or causing heating damage15,16. Minoxidil (Mx)-coated albumin-shelled MBs produced in a layer-by-layer manner combined with sonication by US energy in the water phase successively enhanced hair growth while shortening the treatment period17.
In comparison to single-frequency US sonication, multiple-frequency US excitation can markedly enhance the acoustic cavitation effect18. Dual-frequency US has been used to facilitate diagnoses via real-time superharmonic imaging19 and to enhance transdermal transport for therapeutic applications20. Dual-frequency US has involved combining US at a low frequency (ranging from 20 to 60 kHz) with high-frequency US (ranging from 1 to 3 MHz)8. A recent study indicated that dual-frequency US may be a useful treatment option for rosacea that is resistant to other treatments21. This method has emerged as a new treatment modality for improving inflammatory skin disorders. Moreover, in our previous study, dual-frequency US sonication generates more cavitation activity that may stimulate neural stem/progenitor cell differentiation and growth factor utilization, while not causing any damage22. The biological effect due to dual-frequency US exposure was found to be significantly higher than single-frequency US exposure, and we have shown that this correlated to the enhanced cavitation effect during dual-frequency US exposure. Some previous studies proposed the dual- and multiple-frequency US excitation generated from separate piezoelectric transducers23–25. However, our previous study demonstrated that dual- or multiple-frequency US wave irradiations are possible to be generated from a single crystal once the driving frequency matches the characteristic frequency of the transducer26,27, making the dual- or multiple-frequency US irradiation more feasible and bring opportunity for biomedical application such as transdermal drug delivery (TDD) enhancements.
MBs are contrast agents that are commonly used in contrast-enhanced US imaging of blood perfusion in organs, to detect the blood flow rate in the heart, and many other applications28. The effects of US-mediated albumin-shelled-MB cavitation in TDD were demonstrated in our recent study15,16. The following characteristics of MBs vary with their size: resonance frequency, expansion ratio, pressure threshold for inertial cavitation and fragmentation, translational velocity, and lifetime of stable oscillations29. The efficacy of US-mediated MB cavitation in increasing tissue permeability was dependent on the size distribution for the same acoustic pressure15,30. By utilizing nonisolated MBs with nonuniform sizes, dual-frequency US might be able to increase the efficacy of TDD. Therefore, in this study we aimed to demonstrate the potential of using dual-frequency US-mediated MB cavitation to enhance TDD.
Our previous study provided a new integrated TDD platform for monitoring the delivery of Mx to hair follicles by utilizing multifunctional albumin-shelled MBs and single-frequency US17. The present study is the first to investigate the potential of single- and dual-frequency US sonication for TDD and to enhance hair follicle growth both in vitro and in vivo with Mx or Mx mixed in MBs.
Materials and Methods
Preparation of albumin-shelled MBs
Albumin-shelled MBs were prepared in our laboratory according to the procedure used in our previous studies15–17. Briefly, albumin-shelled MBs were generated by 2 min of sonication (Branson Ultrasonics, Danbury, CT, USA) of 10 mL of a solution containing 132 mg of albumin (Octapharma, Vienna, Austria) and perfluoropropane (C3F8) gas in physiological saline (pH 7.4, 0.9% sodium chloride). The albumin-shelled MBs had a diameter of 1.02 ± 0.11 μm (mean ± SD) and a concentration of 1.40 × 108 MBs/mL.
Passive cavitation detection of single- and dual-frequency US-mediated MB cavitation
The apparatus and experimental design for the low-frequency single- and dual-frequency US sonication of a target are shown in Fig. 1A,B. A customized single- or dual-frequency US apparatus was employed in this study. The US sonication device was operated at 1 MHz and 666 kHz (1 MHz in single-frequency mode). A polyvinylidene–difluoride (PVDF) type hydrophone (Onda, Sunnyvale, California, USA; calibration range 50 kHz to 20 MHz) was mounted on a three-dimensional positioning system to measure the emission pressure distribution induced by the spherically-curved ultrasound phased arrays. The transducer was powered by a custom-designed multiple-channel driving system with bursts or continuous waves in single-frequency or dual-frequency excitation mode to produce a peak pressure of 120 kPa. The exposure pressure of this dual-frequency US transducer reached 80 kPa for both 1 MHz and 666 kHz, with a drive burst duty cycle of 20%. The transducer of a single- and dual frequency US system and a PCD were arranged confocally using a self-made holder with an included angle of approximately 120°31. A polyethylene (PE) tube filled with degassed water was placed in a degassed water tank 7 mm below the water surface (measured from the dual-frequency transducer to the center of the PE tube) for passive cavitation detection (PCD)31. The total sonication time was 240 s, and 0.5 mL of MB solution was injected at 60 s. During US sonication from 60 s to 180 s, the detector was a single-element spherically focused 1-MHz transducer with a diameter of 12.5 mm (V303-SU, Olympus, Tokyo, Japan). The transducer holder was mounted on a computer-controlled two-dimensional (2D) motion stage (HR8, Nanomotion, Yokneam, Israel). The emissions associated with MB cavitation were received by the 1-MHz transducer and then amplified by a broadband receiver (BR-640, Retec, Warwick, RI, USA). The detected emissions were then quantified using energy-spectral-density analysis with MATLAB (The MathWorks, Natick, MA, USA).
PCD analysis
Passive cavitation emissions were received by a commercial water-immersion transducer and recorded on a personal computer using a PCI-based oscilloscope at a sampling rate of 60 MHz with 8,192 sampling points. The stable cavitation (subharmonic and harmonic components) and inertial cavitation (all accumulated energy excluding the fundamental and harmonic frequencies) were characterized, respectively. The oscilloscope was synchronized using triggers from the US sonication system. The energy spectral density (ESD; in units of V2·s·Hz−1) at frequency ω used to calculate the cavitation dose was defined as follows22:
1 |
where F(jω) is the fast Fourier transform of the passive emission signal in the time domain and B is the designated computation bandwidth. In our experiment designed to analyze the spectral information with respective to a specific cavitation type, we defined the integral of the stable cavitation dose (SCD) magnitude at the selected frequency including subharmonics (i.e., 0.5 × f0) and ultraharmonics (i.e., 1.5 × f0, 2.5 × f0, …), where f0 is the center frequency (i.e., 1 MHz in this case). The bandwidth was typically set to 15% of the center frequency. In contrast, the inertial cavitation dose (ICD) was calculated as the sum of the wideband-emission ESD over the entire spectrum while excluding the baseband signal (i.e., f0 = 1 MHz), subharmonics (i.e., 0.5 × f0), harmonics (i.e., 2 × f0, 3 × f0, …), and other ultraharmonics (i.e., 1.5 × f0, 2.5 × f0, …).
Optimization of US parameters for single- and dual-frequency US-mediated MB cavitation using agarose phantoms
The sonication effects on the skin surface of applying MBs were evaluated by high-frequency US imaging using a commercial animal US imaging system (Prospect, S-Sharp Corporation, New Taipei City, Taiwan) in tissue-mimicking agarose phantoms, as described previously32. A 2%-agarose square-column phantom (10 mm × 20 mm × 20 mm) was constructed with a chamber (2 mm × 2 mm × 20 mm3) at its center to load 400 μL of 1.4 × 108 MBs/mL (no dilution, group MB1), 1.4 × 107 MBs/mL (10-fold dilution, group MB10), and 7 × 106 MBs/mL (20-fold dilution, group MB20), followed by sonication using the single- or dual-frequency US apparatus for 1, 2, 3, and 4 min with the exposure pressure set at 80 kPa.
High-frequency US images were obtained using a transducer with a central frequency of 40 MHz, producing axial and lateral resolutions of 30 and 60 μm, respectively (Prospect, S-Sharp Corporation). The axial and lateral fields of view were 20 and 20 mm, respectively. Real-time B-mode imaging was performed, and the image planes were acquired with optimization of the gain and the time-gain compensation settings, which were kept constant throughout the experiments. Images were processed with custom MATLAB programs to evaluate the destruction efficiency32. The region of interest was drawn over the entire MB-loaded chamber in 2D imaging planes by the operator, the dynamic range was 50 dB, and the average pre- and postsonication image intensities were measured in B-mode images. The results obtained for the destruction efficiency were used to determine the optimal US sonication duration, and this was used in the subsequent in vitro and in vivo experiments. The MB destruction efficiency was calculated according to the image intensity using the following equation:
2 |
where I0 is the image intensity for the original MBs and In is the image intensity of MBs for different US destruction parameters.
Penetration depth measurements in pigskin
Fresh pigskin was obtained from the slaughterhouse affiliated to New Taipei City Meat Market. The ability to increase the penetration depth using single- or dual-frequency US-mediated MB cavitation was measured using fresh pigskin samples, with the duration from purchase to the completion of experiments being no more than 6 hours. Circular samples of pigskin from the ear were produced with a radius of 3 cm and a thickness of 3 mm. The round area of each pigskin surface were encircled with gel to prevent leakage and then loaded with model drug, Evans blue (0.1 mg; molecular weight = 960.81 Da; E2129, Sigma-Aldrich, St Louis, MO, USA) or MBs. Before US sonication, 3 mL of MBs was loaded into the treatment area of the sample and then sonication was performed successively at an exposure pressure of 80 kPa for 3 min using a single- or dual-frequency US transducer attached to the top of the sample. After removing the MBs solution from groups MB1, MB10, and MB20, 1 mL of Evans blue (0.25% w/w) was added and left for 15 min, and then the area was washed with phosphate buffered saline (PBS) three times for 1 min each.
The treated areas of pigskin were then embedded on round specimen disks (with a diameter of 2.2 cm) and placed on the –25 °C freezing stage of a cryostat (Microm HM550 series, Thermo Fisher Scientific, Bremen, Germany) for about 30 min15,32. The transverse sectioning was then performed at a slice thickness of 10 μm. Sections attached to the microscopy slides were air-dried at room temperature and mounted, with the distribution of the Evans blue in the cryosections determined with the aid of an upright microscope (DM 2500, Leica Microsystems). The results obtained for the penetration depth in pigskin revealed the optimal MB concentration for use with US sonication, and this was used in the subsequent in vitro and in vivo experiments.
In vitro skin penetration by Mx
Static Franz diffusion cells over an area of 2.14 cm2 were maintained at 37 °C and used for the in vitro skin penetration experiments according to the procedure used in our previous study15–17. A 2-mm-thick fresh sample of pigskin (with the duration from purchase to the completion of experiments being no more than 6 hours) obtained from ear that included hair follicles was harvested using a Humby knife, carefully cleaned with PBS, and cut into square pieces (2 cm × 2 cm). The MB solution or 0.4 mg of Mx (molecular weight = 209.25; Sigma-Aldrich, St. Louis, MO, USA) in PBS (1 mL) (as a control) was applied to the donor cells facing the stratum corneum side of the skin, and occluded with Parafilm (Pechiney Laboratory Safety Products and Apparel, Chicago, IL, USA). The PBS (pH 7.4, 4.5 mL) was filled in receptor diffusion half cell facing the dermis side; that cell contained a magnetic stirring bar rotating at 600 rpm and 0.01% gentamicin to prevent bacterial degradation of the Mx during the penetration process. Solutions (without MBs) in the diffusion cell were filtered through a 0.22-μm micropore filter (Millex, Darmstadt, Germany)15–17. Aliquots (250 μL) of receptor solution were taken after various time points (0, 0.25, 0.55, 1, 2, 4, 6, 10, and 18 hours), with the cell refilled each time with the same volume of fresh receptor solution. After 0.5 hours, the 1-MHz single- or 1 MHz and 666 kHz dual-frequency US transducer was positioned 3 mm from the top of the skin to provide sonication at an exposure pressure of 80 kPa for 3 min. Samples were kept in a freezer until being analyzed using a UV-visual spectrophotometer (Lambda 40, Perkin Elmer, Bridgeville, PA, USA)17.
The skin sample (i.e., after 18 hours) detached from the diffusion cell was carefully rinsed five times, cut into 0.1-g pieces, and homogenized with 2 mL of receptor solution for 2 min at 10,000 rpm (Polytron-Aggregate PT3100, Kinematica, Luzern, Switzerland)15,33. The homogenized suspension was centrifuged for 25 min at 3,100 × g (Thermo Fisher Scientific), and then a UV-visual spectrophotometer was used to determine the Mx concentration in the supernatant. A sample volume of 200 μl was added to the cuvette and placed in the spectrophotometer to measure the Mx concentration. The Mx calibration curve served as the standard curve against which the absorption peaks and the corresponding concentrations of Mx in the samples were measured15.
In vivo animal experiments
The animal experimental protocol was approved by the Institutional Animal Care and Use Committee of the National Defense Medical Center, Taipei, Taiwan. Animals were cared for in compliance with institutional guidelines and regulations (No. IACUC-13-063). The animals were housed in stainless-steel cages in an air-conditioned room with the temperature maintained at 25–28 °C and with alternating light and dark periods of 12 hours each throughout the experiments. The Six-week-old C57BL/6 mice weighing 20–25 g were obtained from Bio Lasco (Taipei, Taiwan) and divided into the following five groups (n = 5 per group, treatment applied once daily for 3 weeks): (i) Mx alone (group C), (ii) single-frequency US (1 MHz) and penetrating Mx (group S), (iii) dual-frequency US (1 MHz and 666 kHz) and penetrating Mx (group D), (iv) single-frequency US combined with 10-fold-diluted MBs and penetrating Mx (group S + MB10), and (v) dual-frequency US combined with 10-fold-diluted MBs and penetrating Mx (group D + MB10).
A schematic illustration of the experimental procedure was shown in Fig. 1C. An area of about 10 cm2 of the dorsal skin of each animal was shaved using animal clippers when the animal was 8 weeks of age, at which time all of the hair follicles were synchronized in the telogen phase, and the skin color was measured using the CR-400 Chroma Meter device (Konica Minolta Sensing, Tokyo, Japan). The single-frequency (1 MHz) or dual-frequency (1 MHz and 666 kHz) US transducer was applied at an exposure pressure of 80 kPa for 3 min, and 0.4 mg/mL Mx (corresponding to 3 mL/3.14 cm2) was used in all cases. The change in skin color induced by each of the treatments was assessed at predetermined times using the Chroma Meter. The luminosity index, L, was calculated on each measurement day before and after treatment34. The hair growth rate was calculated according to the L value using the following equation:
3 |
where L1 is the luminosity index immediately after removing the hair and Ln is the luminosity index at each measurement time point.
Histochemistry
The 8 mm × 8 mm skin tissue samples were cut from the treatment area immediately after the experiments and stored in a 10% formalin solution. Hematoxylin and eosin (Sigma-Aldrich) staining was applied, and the thickness, diameter, and number of hair follicles were analyzed using an image analysis system (TissueFAXS 3.5, TissueGnostics, Vienna, Austria) using both the scanner (TissueQuest) and cytometry (HistoQuest) analysis packages provided with that system11.
Statistical analysis
The obtained data were analyzed statistically using Student’s t-test. A probability value of p < 0.05 was considered indicative of a significant difference.
Results
PCD of single- and dual-frequency US-mediated MB cavitation
Figure 2 shows that cavitation occurred more easily in the dual-frequency US group than in the single-frequency group, whose design was similar to one described previously16. The SCD values during dual-frequency sonication were 1016.18 ± 172.13, 468.03 ± 66.55, and 323.63 ± 88.07 mV2·s/Hz in groups MB1, MB10, and MB20, respectively; the corresponding ICD values were 3426.92 ± 554.95, 2062.21 ± 266.54, and 989.01 ± 296.50 mV2·s/Hz. Both SCD and ICD during dual-frequency US sonication were correlated with the MB concentration. In comparison, the ESD during single-frequency US sonication was not reliable, with SCD values of 132.29 ± 32.76, 158.045 ± 53.07, and 159.45 ± 39.56 mV2·s/Hz in groups MB1, MB10, and MB20, respectively, and ICD values of 1974.28 ± 323.03, 1878.02 ± 501.73, and 2410.65 ± 464.34 mV2·s/Hz; the ICD was not correlated with the MB concentration. Dual-frequency US stimulation triggered more apparent stable cavitation than single-frequency US in group MB1, MB10, and MB 20. The inertial cavitation has also been enhanced during dual-frequency than single-frequency sonication in groups MB1 and MB10 (especially in group MB1). In General, dual-frequency US has been shown to significantly enhanced MB-presented acoustic cavitation effect.
Optimization of US parameters for single- and dual-frequency US-mediated MB cavitation
High-frequency US images of groups MB10 and MB20 without and with single- or dual-frequency US sonication for 1, 2, 3, and 4 min are shown in Fig. 3A–D, respectively, with the destruction efficiencies quantified in Fig. 3E. The destruction efficiencies in group MB10 for 1, 2, 3, and 4 min of sonication were 35.9%, 43.0%, 64.1%, and 71.7%, respectively, for single-frequency US sonication, and 59.1%, 74.8%, 81.3%, and 82.9% for dual-frequency US sonication. The destruction efficiencies in group MB20 for 1, 2, 3, and 4 min of sonication were 70.5%, 79.0%, 85.6%, and 88.4%, respectively, for single-frequency US sonication, and 70.7%, 77.2%, 80.9%, and 82.7% for dual-frequency US sonication. The destruction efficiencies reached to plateau for MBs at the 10-fold dilution with sonication for 3 min either in single or in dual-frequency US, and so this was used in the subsequent in vitro and in vivo experiments.
The temperature in the chamber during sonication at the different US powers increased by 1.25–1.80 °C. In this experiment, applying US at an exposure pressure of 80 kPa for 3 min almost destroyed all of the MBs in groups MB10 and MB20, and this was the highest efficiency setting in the subsequent in vitro and in vivo hair-growth experiments.
Model drug penetration depth in pigskin with single- and dual-frequency US-mediated MB cavitation
The results of the in vitro skin permeation studies in Fig. 4 demonstrate the ability of dual-frequency US-mediated MB cavitation in groups MB10 and MB20 to act on the hair follicle so as to facilitate Evans blue (EB) penetration as compared to single-frequency US cavitation. The pigskin samples with no treatment (group C) and after sonicating the saline (Fig. 4A) and in groups MB10 (Fig. 4B) and MB20 (Fig. 4C) with single- and dual-frequency US sonication were then cryosectioned for light-microscopy evaluation at a magnification of ×400 (Primo Star, Zeiss-Jena, Jena, Germany). Figure 4D quantifies the penetration depths in the three experimental groups (n=5). The degrees of penetration in both the cuticle and the epidermis were significantly greater for dual-frequency US sonication than for single-frequency US sonication, and were greatest in group MB10 (p < 0.001). The overall penetration depth in group C was 18.0 ± 2.36 μm, and this increased to 33.3 ± 2.87 and 51.4 ± 7.16 μm for sonication with single- and dual-frequency US in group MB10. EB penetration under single-frequency US exposure reached 38.1 ± 2.97 μm in group MB20, and was more significant than saline (30.9 ± 3.66 μm) and MB10 (33.3 ± 2.87 μm). In the contrast, EB penetration under dual-frequency US exposure reached 51.4 ± 7.16 μm in group MB10, and was more significant than saline (38.4 ± 3.00 μm) and MB20 (41.1 ± 5.11 μm). The penetration depth and uniformity both reached maximum for dual-frequency US sonication in group MB10, therefore this condition was used in the subsequent experiments involving in vitro skin permeation and in vivo animal treatments.
In vitro skin permeation of Mx
Figure 5 shows the Mx concentrations in the five groups for percutaneous penetration over 18 hours as analyzed using the UV-visual spectrophotometer. The concentration in all groups increased rapidly during the first 6 hours and then gradually leveled off from 6 to 18 hours. At 18 hours the concentrations were significantly higher (p < 0.05) in group D + MB10 (81.5%) and group D (73.6%) than in groups S (65.7%), S + MB10 (56.6%), and C (37.8%). The concentration did not differ significantly (p > 0.05) between groups S and S + MB10. The penetration of Mx at 18 hour were 7.9% and 24.9% higher in group D + MB10 than in groups D and S + MB10, respectively. The transdermal Mx penetration was significantly higher in group D than in group S (p < 0.01), and in group D + MB10 than in groups D (p < 0.001) and S + MB10 (p < 0.001), respectively. Table 1 indicates that the amount of Mx deposited in the skin was significantly greater in group C than in the other four groups at 18 hours. The total amount of Mx that penetrated was significantly greater in group D + MB10 than in the other four groups.
Table 1.
Parameter | Skin weight (g) | Amount of Mx deposited on skin (μg/cm2) | Amount of Mx penetrated across skin (μg/cm2) | Total amount of Mx permeated (μg/cm2) |
---|---|---|---|---|
Group | ||||
C | 0.157 ± 0.026 | 75.41 ± 2.09 (18.9%) | 151.25 ± 10.20 (37.8%) | 226.65 ± 12.29 (56.7%) |
S | 0.168 ± 0.032 | 56.86 ± 3.33 (14.2%) | 262.71 ± 17.10 (65.7%) | 319.57 ± 20.43 (79.9%) |
S + MB10 | 0.171 ± 0.033 | 62.81 ± 3.13 (15.7%) | 226.40 ± 18.77 (56.6%) | 289.21 ± 21.90 (72.3%) |
D | 0.143 ± 0.021 | 50.08 ± 1.12 (12.5%) | 294.21 ± 19.81 (73.6%) | 344.29 ± 20.93 (86.1%) |
D + MB10 | 0.131 ± 0.026 | 45.77 ± 2.15 (11.4%) | 326.19 ± 18.63 (81.5%) | 371.97 ± 20.78 (92.9%) |
Data are mean ± SD values.
In vivo hair growth enhancement with MB-enhanced dual-frequency US sonication
Figure 6A shows photographs of mouse skin in an untreated animal (day 1) and in groups C, S, D, S + MB10, and D + MB10 at various time points after treatment. At day 9, the skin brightness for the five mice in group D + MB10 was more effectively decreased compared to groups S + MB10 (decreased in four mice), D (decreased in four mice), S (decreased in four mouse), and C (decreased in two mice). At day 12, the hair growth was greater in all mice in group D + MB10 than in the other four groups.
Figure 6B demonstrates the effects of Mx on dorsal hair growth over 21 days. At days 11 and 14, the growth rates in group D + MB10 had increased by 32.4% and 64.2%, respectively. At day 11 there were obvious significant differences (p < 0.05) between group D + MB10 and the other four groups. At day 16, the growth rate had reached a plateau in group D + MB10, with an increase of 77.1%, while the growth rates in groups C, S, D, and S + MB10 had increased by 58.6%, 69.3%, 72.6%, and 64.3%, respectively. At that time point the growth rate did not differ significantly between groups D + MB10 and D (p > 0.05).
The histology images in Fig. 7 indicate that no skin damage was evident in any of the US sonication groups. Histological analysis of transverse and coronal sections (Fig. 7) revealed significant increases in the diameter (Fig. 8) of keratinized hair shafts after 21 days in groups S, S + MB10, D, and D + MB10. The enhancements of keratinized hair shafts were greatest in groups D and D + MB10, and was more significantly increased in group D + MB10 than in group D (p < 0.05). Moreover, the number of hair follicles in groups D and D + MB10 was increased after treatment in Fig. 7.
Discussion
Dual-frequency US sonication of MBs induces larger cavitation-related emissions due to radial oscillations occurring at higher harmonics35. Dual-frequency excitation is known to be an efficient method for enhancing the cavitation of MBs in sonography as well as for minimizing any associated unwanted damage35. Figure 2 shows that the SCD values for various concentrations of MBs were more evident in dual-frequency US sonication, and this is consistent with theoretical expectations; however, during single-frequency sonication, the cavitation dose did not provide a useful index for the MB concentration. This confirms that using multifrequency US sonication improves the utilization of MBs for transdermal applications.
This study demonstrated that both stable and inertial cavitation can be enhanced during dual-frequency sonication under the presence of microbubbles. We observed that dual-frequency US at an appropriate intensity provided higher stable cavitation activity than single-frequency US, which can be utilized to stimulate cell membrane mechanochannels without inducing cell damage22,26,27. Cavitation was found to be proportional to MBs concentration in dual-frequency US stimulation group, but not in single-frequency US group. During the PCD test, we estimated that cavitation lasted for about 3 and 4 min during single- and dual-frequency US sonication, respectively, at 80 kPa in groups MB10 and MB20. In high-frequency US imaging, the destruction of MBs was compared with the penetration depths measured in pigskin. The penetration depth is related to the destruction efficacy of MBs, and this was greatest in group MB10 for 3 min of dual-frequency US sonication. Therefore, this exposure condition was used in the subsequent in vitro and in vivo hair-growth experiments.
Our previous in vitro profiles for the permeation of Mx through skin samples mediated by 140 kPa US (3 W/cm2 for 1 min; ST2000V, Nepagene, Ichikawa, Japan) indicate that the concentrations increased more rapidly in the group that combined US sonication and MBs and included Mx separately than in the other groups during the first 6 hours, and then became closer to or even lower than those in the group with US sonication and Mx-coated MBs from 6 to 18 hours17. The present study results indicate that combining single-frequency US sonication with MBs increased the permeation more than that in the control group at all measurement time points. However, the permeated concentration did not differ between single-frequency US sonication alone and single-frequency US sonication combined with MBs at first 4 hours. This might have been due to single-frequency US sonication at 80 kPa not destroying MBs completely and thereby reducing the efficacy of inertial cavitation by MBs. Under the same 80-kPa acoustic pressure, dual-frequency US sonication and dual-frequency US-mediated MB cavitation increased the permeation more rapidly relative to the other groups throughout the 18-hour experiments, with this being greater when MBs were included. The results indicated that dual-frequency US sonication induced greater inertial cavitation and is a more efficient method than single-frequency US sonication, and so allows the use of lower and hence safer acoustic pressures. Moreover, dual-frequency US sonication combined with MB cavitation enhanced TDD more significantly compared to using dual-frequency US sonication alone.
Topical Mx (Rogaine) is approved for the treatment of androgenetic alopecia (AGA) and the only medication that can be used by both men and women36. AGA is the most common cause of hair loss and is induced by androgens in genetically susceptible hair follicles. In such hair follicles dihydrotestosterone binds to the androgen receptor and this hormone–receptor complex then activates the genes that control the gradual transformation of large, terminal follicles into small, miniaturized follicles17,37. However, Mx does not work on completely bald areas and only works over the long term if it is used continuously. In the present study, we observed that in vivo hair growth enhancement with Mx was greater in group D + MB10 than in the other groups. The hair growth rate from 9 to 14 days did not differ significantly among groups D, S, and S + MB10. However, the histology (Fig. 7) confirmed that the diameters of keratinized hair shafts after 21 days were significantly increased in groups D and D + MB10 compared to in groups S and S + MB10 (Fig. 8). There was greater variability for dual-frequency US sonication alone than for dual-frequency US sonication combined with MBs. We therefore assume that the addition of MBs facilitates the stability of dual-frequency US sonication for hair growth enhancement.
Conclusion
This study investigated a novel dual-frequency US sonication technique for increasing the efficacy of Mx in enhancing hair growth. Combining dual-frequency US sonication with MBs can enhance cavitation more significantly during dual-frequency sonication than single-frequency sonication in higher concentration of MBs. This method enhances both the deposition of Mx into the skin and the penetration of Mx across the skin in vitro, and increase hair growth than in the other groups at most of the measurement time points in in vivo small-animal study. Histology images revealed that dual-frequency US sonication can increase the diameter of keratinized hair shafts, and combining dual-frequency US with MBs can improve the variability in hair growth enhancement.
Acknowledgements
This work was supported in part by grants from the Ministry of Science and Technology, Taiwan (MOST108-2221-E-011-161-MY4 to A.H.L.) and the National Taiwan University of Science and Technology/Tri-Service General Hospital Joint Research Program (NTUST-TSGH-108-01 to A.H.L.).
Author contributions
K.H.L. performed the experiments and A.H.L. wrote the manuscript. A.H.L., H.L.L., H.C.C., C.H.T., Y.C. L., C.H.W., and C.P.S. participated in planning and performing the experiments. C.H.T., H.L.L., and A.H.L. participated in data analysis and interpretation. A.H.L., H.L.L., and C.H.T. made substantial contributions to the conception and design of the research, data collection, and the editing of the manuscript. All authors reviewed the manuscript and approved its final version.
Competing interests
The authors declare no competing interests.
Footnotes
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Contributor Information
Ai-Ho Liao, Email: aiho@mail.ntust.edu.tw.
Hao-Li Liu, Email: haoliliu@mail.cgu.edu.tw.
References
- 1.Mitragotri S. Sonophoresis: a 50-year journey. Drug. Discov. Today. 2004;9:735–736. doi: 10.1016/S1359-6446(04)03209-X. [DOI] [PubMed] [Google Scholar]
- 2.Oberli MA, Schoellhammer CM, Langer R, Blankschtein D. Ultrasound-enhanced transdermal delivery: recent advances and future challenges. Ther. Deliv. 2014;5:843–857. doi: 10.4155/tde.14.32. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Azagury A, Khoury L, Enden G, Kost J. Ultrasound mediated transdermal drug delivery. Adv. Drug. Deliv. Rev. 2014;72:127–143. doi: 10.1016/j.addr.2014.01.007. [DOI] [PubMed] [Google Scholar]
- 4.Canavese G, et al. Nanoparticle-assisted ultrasound: a special focus on sonodynamic therapy against cancer. Chem. Eng. J. 2018;340:155–172. doi: 10.1016/j.cej.2018.01.060. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Park D, Park H, Seo J, Lee S. Sonophoresis in transdermal drug deliverys. Ultrason. 2014;54:56–65. doi: 10.1016/j.ultras.2013.07.007. [DOI] [PubMed] [Google Scholar]
- 6.Boucaud A, et al. Clinical, histologic, and electron microscopy study of skin exposed to low-frequency ultrasound. Anat. Rec. 2001;264:114–119. doi: 10.1002/ar.1122. [DOI] [PubMed] [Google Scholar]
- 7.Seah BCQ, Teo BM. Recent advances in ultrasound-based transdermal drug delivery. Int. J. Nanomed. 2018;13:7749–7763. doi: 10.2147/IJN.S174759. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Schoellhammer CM, et al. Rapid skin permeabilization by the simultaneous application of dual-frequency, high-intensity ultrasound. J. Control. Rel. 2012;163:154–160. doi: 10.1016/j.jconrel.2012.08.019. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Deckers R, Moonen CTW. Ultrasound triggered, image guided, local drug delivery. J. Control. Rel. 2010;148:25–33. doi: 10.1016/j.jconrel.2010.07.117. [DOI] [PubMed] [Google Scholar]
- 10.Mitragotri S, Blankschtein D, Langer R. Ultrasound-mediated transdermal protein delivery. Sci. 1995;269:850–853. doi: 10.1126/science.7638603. [DOI] [PubMed] [Google Scholar]
- 11.Benson HAE, McElnay JC, Harland R. Use of ultrasound to enhance percutaneous absorption of benzydamine. Phys. Ther. 1989;69:113–118. doi: 10.1093/ptj/69.2.113. [DOI] [PubMed] [Google Scholar]
- 12.Kushner JT, Blankschtein D, Langer R. Evaluation of the porosity, the tortuosity, and the hindrance factor for the transdermal delivery of hydrophilic permeants in the context of the aqueous pore pathway hypothesis using dual-radiolabeled permeability experiments. J. Pharm. Sci. 2007;96:3263–3282. doi: 10.1002/jps.20955. [DOI] [PubMed] [Google Scholar]
- 13.Dahlan A, Alpar HO, Stickings P, Sesardic D, Murdan S. Transcutaneous immunisation assisted by low-frequency ultrasound. Int. J. Pharm. 2009;368:123–128. doi: 10.1016/j.ijpharm.2008.10.014. [DOI] [PubMed] [Google Scholar]
- 14.Bhatnagar S, Kwan JJ, Shah AR, Coussios CC, Carlisle RC. Exploitation of sub-micron cavitation nuclei to enhance ultrasound-mediated transdermal transport and penetration of vaccines. J. Control. Rel. 2016;238:22–30. doi: 10.1016/j.jconrel.2016.07.016. [DOI] [PubMed] [Google Scholar]
- 15.Liao AH, Ho HC, Lin YC, Chen HK, Wang CH. Effects of microbubble size on ultrasound-induced transdermal delivery of high-molecular-weight drugs. PLoS One. 2015;10:e0138500. doi: 10.1371/journal.pone.0138500. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Liao AH, Ma WC, Wang CH, Yeh MK. Penetration depth, concentration and efficiency of transdermal α-arbutin delivery after ultrasound treatment with albumin-shelled microbubbles in mice. Drug. Deliv. 2016;23:2173–2182. doi: 10.3109/10717544.2014.951102. [DOI] [PubMed] [Google Scholar]
- 17.Liao AH, et al. Effectiveness of a layer-by-layer microbubbles-based delivery system for applying minoxidil to enhance hair growth. Theranostics. 2016;6:817–827. doi: 10.7150/thno.14932. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Carpendo L, Ciuti P, Francescutto A. Space-time interaction of two ultrasonic fields and sonoluminescence during transient cavitation in distilled water. Acoust. Lett. 1987;11:178–181. [Google Scholar]
- 19.Wang Z, Martin KH, Dayton PA, Jiang X. Real-time ultrasound angiography using superharmonic dual-frequency (2.25 MHz/30 MHz) cylindrical array: in vitro study. Ultrason. 2018;82:298–303. doi: 10.1016/j.ultras.2017.09.012. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Schoellhammer CM, et al. Applicability and safety of dual-frequency ultrasonic treatment for the transdermal delivery of drugs. J. Control. Rel. 2015;202:93–100. doi: 10.1016/j.jconrel.2015.02.002. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Park JY, Ahn MK, Cho EB, Park EJ, Kim KH. Dual-frequency ultrasound as a new treatment modality for refractory rosacea: a retrospective study. Dermatol. Surg. 2018;44:1209–1215. doi: 10.1097/DSS.0000000000001552. [DOI] [PubMed] [Google Scholar]
- 22.Lee IC, Wu HJ, Liu HL. Dual-frequency ultrasound induces neural stem/progenitor cell differentiation and growth factor utilization by enhancing stable cavitation. ACS Chem. Neurosci. 2019;10:1452–1461. doi: 10.1021/acschemneuro.8b00483. [DOI] [PubMed] [Google Scholar]
- 23.Barati AH, Mokhtari-Dizaji M, Mozdarani H, Bathaie Z, Hassan ZM. Effect of exposure parameters on cavitation induced by low-level dual-frequency ultrasound. Ultrason. Sonochem. 2007;14:783–789. doi: 10.1016/j.ultsonch.2006.12.016. [DOI] [PubMed] [Google Scholar]
- 24.Lernetti G, et al. Enhancement of high-frequency acoustic cavitation effects by a low-frequency stimulation. Ultrason. Sonochem. 1997;4:263–268. doi: 10.1016/S1350-4177(97)00034-5. [DOI] [PubMed] [Google Scholar]
- 25.Sokka SD, Gauthier TP, Hynynen K. Theoretical and experimental validation of a dual-frequency excitation method for spatial control of cavitation. Phys. Med. Biol. 2005;50:2167–2179. doi: 10.1088/0031-9155/50/9/017. [DOI] [PubMed] [Google Scholar]
- 26.Lee IC, Fadera S, Liu HL. Strategy of differentiation therapy: effect of dual-frequency ultrasound on the induction of liver cancer stem-like cells on a HA-based multilayer film system. J. Mater. Chem. B. 2019;7:5401–5411. doi: 10.1039/C9TB01120J. [DOI] [PubMed] [Google Scholar]
- 27.Liu HL, Hsieh CM. Single-transducer dual-frequency ultrasound generation to enhance acoustic cavitation. Ultrason. Sonochem. 2009;16:431–438. doi: 10.1016/j.ultsonch.2008.08.009. [DOI] [PubMed] [Google Scholar]
- 28.Blomley MJ, Cooke JC, Unger EC, Monaghan MJ, Cosgrove DO. Microbubble contrast agents: a new era in ultrasound. BMJ. 2001;322:1222–1225. doi: 10.1136/bmj.322.7296.1222. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Sassaroli E, Hynynen K. Resonance frequency of microbubbles in small blood vessels: a numerical study. Phys. Med. Biol. 2005;50:5293–5305. doi: 10.1088/0031-9155/50/22/006. [DOI] [PubMed] [Google Scholar]
- 30.Choi JJ, et al. Microbubble-size dependence of focused ultrasound-induced blood-brain barrier opening in mice in vivo. IEEE Trans. Biomed. Eng. 2010;57:145–154. doi: 10.1109/TBME.2009.2034533. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Fan CH, et al. Submicron-bubble-enhanced focused ultrasound for blood–brain barrier disruption and improved CNS drug delivery. PLoS One. 2014;9:e96327. doi: 10.1371/journal.pone.0096327. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Liao AH, Lu YJ, Hung CR, Yang MY. Efficacy of transdermal magnesium ascorbyl phosphate delivery after ultrasound treatment with microbubbles in gel-type surrounding medium in mice. Mater. Sci. Eng. C. Mater Biol. Appl. 2016;61:591–598. doi: 10.1016/j.msec.2015.12.058. [DOI] [PubMed] [Google Scholar]
- 33.Liao AH, et al. Combining microbubble contrast agent with pulsed-laser irradiation for transdermal drug delivery. Pharmaceutics. 2018;10:pii: E175. doi: 10.3390/pharmaceutics10040175. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Tsai YH, Lee KF, Huang YB, Huang CT, Wu PC. In vitro permeation and in vivo whitening effect of topical hesperetin microemulsion delivery system. Int. J. Pharm. 2010;388:257–262. doi: 10.1016/j.ijpharm.2009.12.051. [DOI] [PubMed] [Google Scholar]
- 35.Liu Y, Calvisi ML, Wang Q. Nonlinear oscillation and interfacial stability of an encapsulated microbubble under dual-frequency ultrasound. Fluid Dyn. Res. 2017;49:025518. doi: 10.1088/1873-7005/aa5dad. [DOI] [Google Scholar]
- 36.Springer K, Brown M, Stulberg DL. Common hair loss disorders. Am. Fam. Physician. 2003;68:93–102. [PubMed] [Google Scholar]
- 37.Price VH. Androgenetic alopecia in women. J. Investig. Dermatol. Symp. Proc. 2003;8:24–7. doi: 10.1046/j.1523-1747.2003.12168.x. [DOI] [PubMed] [Google Scholar]