Abstract
Background
Prior studies have demonstrated an association between appropriate implantable cardioverter defibrillator (ICD) shocks and mortality in clinical trials. The effect of shock burden on heart failure and mortality has not been previously studied in a large population-based cohort.
Methods
The cohort was derived using a comprehensive prospective ICD registry in the province of Nova Scotia with a mean follow-up of 4 ± 2.3 years. With the use of time-varying analysis, the relationship among shock burden, mortality, and heart failure hospitalization was determined.
Results
A total of 776 patients (mean age of 64.8 years) were included in the study, of whom 37% received appropriate therapy during follow-up. A single ICD shock did not confer an increased mortality risk compared with no therapy (hazard ratio [HR], 1.23; 95% confidence interval [CI], 0.84-1.79; P = 0.3), but mortality risk was significantly increased with ≥ 2 shocks (HR, 3.23; 95% CI, 2.04-5.09; P < 0.0001). There was a significant increase in heart failure hospitalization associated with receiving 1 ICD shock (HR, 2.05; 95% CI, 1.46-2.89; P < 0.0001) or more than 1 ICD shock (HR, 4.36; CI, 2.53-7.52; P < 0.0001) compared with patients receiving no ICD therapy. Patients who received antitachycardia pacing alone showed no difference in heart failure hospitalization (HR, 0.93; CI, 0.67-1.29; P = 0.7) and improved survival (HR, 0.69; CI, 0.5-0.96; P = 0.03) compared with those receiving no ICD therapy.
Conclusion
Ventricular arrhythmia treated with appropriate ICD shocks is associated with an increased risk of heart failure hospitalization, whereas recurrent episodes of ventricular arrhythmia requiring shocks are associated with both higher mortality and higher heart failure hospitalization rates.
Résumé
Contexte
Des études menées antérieurement ont révélé l’existence d’un lien entre l’administration appropriée de décharges électriques au moyen d’un défibrillateur cardioverteur implantable (DCI) et la mortalité au cours des essais cliniques. L’effet de telles décharges sur l’insuffisance cardiaque et la mortalité n’avait encore jamais été étudié au sein d’une cohorte d’envergure représentative de la population.
Méthodologie
La cohorte a été établie au moyen d’un registre prospectif exhaustif des DCI implantés chez des patients de la Nouvelle-Écosse ayant fait l’objet d’un suivi moyen de 4 ± 2,3 ans. La relation entre le fardeau imposé par les décharges, la mortalité et l’hospitalisation pour insuffisance cardiaque a été déterminée au moyen d’une analyse en fonction du temps.
Résultats
Au total, 776 patients (âge moyen : 64,8 ans) ont été admis dans l’étude; 37 % d’entre eux avaient reçu un traitement approprié au cours de la période de suivi. Une seule décharge délivrée par un DCI n’augmentait pas le risque de mortalité par rapport à l’absence de traitement (rapport des risques instantanés [RRI] de 1,23; intervalle de confiance [IC] à 95 %, de 0,84 à 1,79; p = 0,3), mais le risque de mortalité était significativement accru chez les patients ayant reçu ≥ 2 décharges (RRI de 3,23; IC à 95 %, de 2,04 à 5,09; p < 0,0001). Le risque d’hospitalisation pour insuffisance cardiaque s’est révélé significativement supérieur chez les sujets ayant reçu 1 décharge par DCI (RRI de 2,05; IC à 95 %, de 1,46 à 2,89; p < 0,0001) ou plus de 1 décharge par DCI (RRI de 4,36; IC à 95 %, de 2,53-7,52; p < 0,0001), comparativement à ceux n’ayant reçu aucun traitement par DCI. On n’a observé aucune différence quant à l’hospitalisation pour insuffisance cardiaque (RRI de 0,93; IC à 95 %, de 0,67 à 1,29; p = 0,7) et à l’amélioration de la survie (RRI de 0,69; IC à 95 %, de 0,5 à 0,96; p = 0,03) chez les patients qui ont reçu uniquement une stimulation antitachycardie comparativement à ceux qui n’ont reçu aucun traitement par DCI.
Conclusion
L’arythmie ventriculaire traitée de façon appropriée au moyen de décharges électriques délivrées par un DCI est associée à un risque accru d’hospitalisation pour insuffisance cardiaque, tandis que des épisodes récurrents d’arythmie ventriculaire exigeant un traitement par décharge électrique sont associés à des taux supérieurs de mortalité et d’hospitalisation pour insuffisance cardiaque.
Implantable cardioverter defibrillators (ICDs) have been shown to be effective in reducing mortality in high-risk patients.1, 2, 3, 4, 5, 6 ICD shocks, however, both appropriate and inappropriate, have been associated with increased mortality in post hoc analyses. This association has not been seen for ventricular arrhythmia treated with antitachycardia pacing (ATP) alone.7, 8, 9 Although previous experimental models have documented myocardial injury secondary to the energy delivered by an ICD shock, a causative link between ICD shocks and clinical outcomes has not been clearly demonstrated.10, 11, 12 It remains unclear whether shocks themselves are detrimental or constitute a marker for increased disease severity. The occurrence of 1 or more ICD shocks has been independently associated with significant reductions in mental well-being, physical function, self-perceived quality of life, increased patient concerns, and anxiety.13, 14, 15 It is uncertain if increasing shock burden further contributes to adverse clinical outcomes. The objective of this study was to examine the relationship among appropriate shocks, shock burden, death, and heart failure in a large cohort with prolonged follow-up.
Methods
Study population
This was a prospective cohort study of all patients receiving an ICD in the province of Nova Scotia from January 1, 2004, to December 31, 2013. This study was approved by the institutional ethics board. Data for patients who underwent ICD implantation before 2006 were collected in a retrospective manner. Data on all other patients were collected from a comprehensive prospective registry. Device follow-up for this cohort was performed as per Canadian guidelines and included remote monitoring follow-up.16 Device programming was left to physician discretion. Shock reduction programming was adopted uniformly as part of routine programming after the follow-up for this study was completed. All patients who underwent ICD implantation for a primary or secondary prophylactic indication and resided in the province of Nova Scotia were included. Patients with hypertrophic cardiomyopathy, infiltrative cardiomyopathy, arrhythmogenic right ventricular cardiomyopathy, ion channelopathies, congenital heart disease, and idiopathic ventricular fibrillation (VF) were excluded from the study. Patient demographics and baseline characteristics including comorbidities were obtained by a trained data abstractor. Implant indication, type of device, ICD therapies, and clinical outcomes including mortality and heart failure hospitalization were collected. Mortality data were obtained through linkage with Vital Statistics of Nova Scotia. Heart failure hospitalization data were obtained through linkage with the Cardiovascular Health Nova Scotia database. The methodology for this study has been described previously.17, 18 Cardiovascular Health of Nova Scotia, a branch of the Department of Health, has maintained a registry of all consecutive patients hospitalized provincially with an acute coronary syndrome or heart failure. ICD programming was left to the discretion of the electrophysiologist.
Patients were divided into 3 groups for the purpose of this analysis based on treatment of ventricular arrhythmia: prior appropriate shock, prior appropriate ATP only, and no appropriate therapy. Patients in the prior appropriate shock group were then analyzed by whether they received 1 or ≥ 2 shocks. Ventricular storm was not analyzed separately in this study.
All delivered ICD therapies were adjudicated by 2 electrophysiologists with a third reviewer for disagreements. Appropriate ICD therapy was defined as either ATP or shock for ventricular tachycardia (VT) or VF. Inappropriate ICD therapy was defined as shocks for any other rhythm or for nonsustained VT. Shock burden was defined as the number of shocks experienced by the patient.
Statistical analysis
Baseline variables were summarized as mean ± standard deviation or frequencies with percentage where appropriate. Comparisons for continuous variables were made using Student t tests or the chi-square test for categoric variables. Cox proportional hazards modeling was used to perform multivariable analyses. The variables included in the multivariable analysis for mortality and heart failure were age, sex, ejection fraction, indication for ICD (primary vs secondary prevention), history of heart failure, and creatinine. Results are presented as hazard ratios (HRs) and 95% confidence intervals (CIs). Shocks were modeled as a time-dependent covariate in all analyses with the risk changing after the occurrence of the first shock episode and subsequent shock episodes. ATP was modeled as a time-dependent covariate in the analysis comparing shocks, no therapy, and ATP only. All P values were 2 sided, and values less than 0.05 were considered statistically significant. Statistical analyses were conducted using SAS software, version 9.4 (SAS Institute Inc, Cary, NC).
Results
Baseline clinical characteristics
Of the 776 patients in the study, 641 (82.6%) were male and mean age at ICD implant was 64.8 ± 11 years. The mean follow-up was 4 ± 2.3 years. Baseline clinical characteristics are shown in Table 1.
Table 1.
Baseline Characteristics
| Characteristic | Total population (n = 776) | No therapy (n = 488) | Any appropriate shock (n = 157) | ≥ 2 appropriate shocks (n = 71) | ATP only (n = 131) |
|---|---|---|---|---|---|
| Age at implant, y (mean ± SD) | 64.8 ± 11 | 64.9 ± 11.5 | 63.1 ± 10.5 | 62.7 ± 10 | 66.4 ± 9.6 |
| Male, n (%) | 641 (82.6%) | 389 (79.7%) | 140 (89.2%) | 63 (88.7%) | 112 (85.5%) |
| EF, % | 27 (21-34) | 27 (21-33) | 27 (21-35.5) | 26 (22-40) | 27 (21-34) |
| QRS duration, ms | 128 (106-160) | 126 (102-162) | 126 (108-154) | 120 (104-150) | 132 (112-170) |
| Creatinine, μmol/L, mean ± SD | 111.6 ± 60.9 | 113.1 ± 69.4 | 110.2 ± 44.7 | 107.1 ± 43.3 | 107.7 ± 40.8 |
| Atrial fibrillation, n (%) | 265 (34.1%) | 159 (32.6%) | 59 (37.6%) | 25 (35.2%) | 47 (35.9%) |
| Coronary artery disease, n (%) | 559 (72%) | 353 (72.3%) | 118 (75.2%) | 54 (76.1%) | 88 (67.2%) |
| Previous PCI, n (%) | 148 (19.1%) | 99 (20.3%) | 28 (17.8%) | 16 (22.5%) | 21 (16%) |
| Previous CABG, n (%) | 242 (31.2%) | 162 (33.2%) | 43 (27.4%) | 22 (31%) | 37 (28.2%) |
| Hypertension, n (%) | 439 (56.6%) | 280 (57.4%) | 91 (58%) | 43 (60.6%) | 68 (51.9%) |
| Dyslipidemia, n (%) | 513 (66.1%) | 313 (64.1%) | 112 (71.3%) | 52 (73.2%) | 88 (67.2%) |
| Diabetes, n (%) | 289 (37.2%) | 188 (38.5%) | 58 (36.9%) | 21 (29.6%) | 43 (32.8%) |
| Current smoker, n (%) | 157 (20.2%) | 95 (19.5%) | 38 (24.2%) | 20 (28.2%) | 24 (18.3%) |
| Heart failure, n (%) | 568 (73.2%) | 370 (75.8%) | 106 (67.5%) | 46 (64.8%) | 92 (70.2%) |
| New York Heart Association Class, n (%) | |||||
| No heart failure | 146 (19.1%) | 93 (19.4%) | 28 (18.3%) | 16 (22.9%) | 25 (19.1%) |
| I | 127 (16.6%) | 71 (14.8%) | 30 (19.6%) | 14 (20%) | 26 (19.8%) |
| II | 240 (31.4%) | 147 (30.6%) | 52 (34%) | 19 (27.1%) | 41 (31.3%) |
| III | 244 (31.9%) | 164 (34.2%) | 41 (26.8%) | 21 (30%) | 39 (29.8%) |
| IV | 7 (0.9%) | 5 (1%) | 2 (1.3%) | 0 (0%) | 0 (0%) |
| Medications, n (%) | |||||
| β-Blocker | 737 (95%) | 456 (93.4%) | 152 (96.8%) | 68 (95.8%) | 129 (98.5%) |
| ACEi or ARB | 710 (91.5%) | 441 (90.4%) | 148 (94.3%) | 67 (94.4%) | 121 (92.4%) |
| Spironolactone | 179 (23.1%) | 117 (24%) | 31 (19.7%) | 13 (18.3%) | 31 (23.7%) |
| Loop diuretic | 456 (58.8%) | 294 (60.2%) | 89 (56.7%) | 34 (47.9%) | 73 (55.7%) |
| Oral anticoagulation | 274 (35.3%) | 172 (35.2%) | 56 (35.7%) | 19 (26.8%) | 46 (35.1%) |
| Digoxin | 183 (23.6%) | 111 (22.7%) | 45 (28.7%) | 22 (31%) | 27 (20.6%) |
| Amiodarone | 105 (13.5%) | 70 (14.3%) | 20 (12.7%) | 10 (14.1%) | 15 (11.5%) |
| Other antiarrhythmic medication | 28 (3.6%) | 12 (2.5%) | 10 (6.4%) | 6 (8.5%) | 6 (4.6%) |
| Implant indication, n (%) | |||||
| Primary prevention | 511 (65.9%) | 350 (71.7%) | 79 (50.3%) | 29 (40.8%) | 82 (62.6%) |
| ICD type, n (%) | |||||
| Single chamber | 427 (55%) | 254 (52%) | 98 (62.4%) | 41 (57.7%) | 75 (57.3%) |
| Dual chamber | 121 (15.6%) | 76 (15.6%) | 28 (17.8%) | 14 (19.7%) | 17 (13%) |
| CRT-D | 228 (29.4%) | 158 (32.4%) | 31 (19.7%) | 16 (22.5%) | 39 (29.8%) |
Continuous variables are shown as median (25th, 75th percentiles) except where specified.
ACEi, angiotensin-converting enzyme inhibitor; ARB, angiotensin receptor blocker; ATP, antitachycardia pacing; CABG, coronary artery bypass grafting; CRT-D, cardiac resynchronization therapy with defibrillation; EF, ejection fraction; ICD, implantable cardioverter defibrillator; PCI, percutaneous coronary intervention; SD, standard deviation.
ICD events
Of the 776 patients included in this study, 157 (20.2%) received a minimum of 1 appropriate ICD shock during the study period, with a mean follow-up of 4 ± 2.3 years. There were 131 patients (16.9%) who received ATP only and 488 patients (62.9%) who received no appropriate therapy. Of patients receiving appropriate ICD shocks, 58 (36.9%) received 1 ICD shock and 99 (63%) received ≥ 2 ICD shocks (Fig. 1).
Figure 1.
Distribution of appropriate shock burden.
ICD therapy and mortality
In unadjusted models, no significant difference in mortality was observed in patients with ATP only versus no therapy (HR, 0.74; 95% CI, 0.53-1.02; P = 0.07) or with 1 shock versus no therapy (HR, 1.11; 95% CI, 0.77-1.61; P = 0.6). Mortality was increased in patients receiving 2 or more appropriate ICD shocks compared with the no therapy group (HR, 2.27; 95% CI, 1.47-3.51; P = 0.0002). On univariate analysis, age (per year) (HR, 1.04; 95% CI, 1.02-1.05; P < 0.0001), left ventricular ejection fraction (per unit) (HR, 0.98; 95% CI, 0.97-1; P = 0.01), creatinine (per decile) (HR, 1.01; 95% CI, 1.01-1.01; P < 0.0001), and history of heart failure (HR, 2.26; 95% CI, 1.49-3.43; P = 0.0001) were found to be associated with an increase in mortality. In a multivariate model, receipt of 2 or more appropriate shocks continued to be associated with increased mortality (HR, 3.23; 95% CI, 2.04-5.09; P < 0.0001), but patients experiencing only appropriate ATP had improved survival compared with those who received no therapy (HR, 0.69; 95% CI, 0.5-0.96; P = 0.03). Receiving a single appropriate shock was not associated with increased mortality (HR, 1.23; 95% CI, 0.84-1.79; P = 0.3) (Fig. 2).
Figure 2.
Forest plot showing adjusted hazard ratios (HRs) with 95% confidence interval (CI) of mortality or heart failure admission. No therapy defined as no appropriate shocks or ATP. A total of 22 patients (3.4%) were excluded from the adjusted multivariable analysis because of missing clinical data. ATP, antitachycardia pacing.
ICD therapy and heart failure admissions
In unadjusted models, no difference in heart failure admissions was observed in patients with ATP only versus no therapy (HR, 0.93; 95% CI, 0.67-1.29; P = 0.7). Risk of heart failure admission increased significantly with a single ICD shock compared with the no therapy group (HR, 1.9; 95% CI, 1.36-2.67; P = 0.0002). This risk increased further still in patients receiving 2 or more shocks (HR, 3.22; 95% CI, 1.9-5.44; P < 0.0001). On univariate analysis, left ventricular ejection fraction (per unit) (HR, 0.98; 95% CI, 0.97-1; P = 0.02), creatinine (per decile) (HR, 1.01; 95% CI, 1-1.01; P < 0.0001) and history of heart failure (HR, 2.61; 95% CI, 1.65-4.13; P < 0.0001) were associated with an increased risk of heart failure admission. In a multivariate model, receiving a single shock continued to be associated with increased risk of heart failure admission (HR, 2.05; 95% CI, 1.46-2.89; P < 0.0001). This risk increased further still in patients receiving 2 or more shocks (HR, 4.36; 95% CI, 2.53-7.52; P < 0.0001). Patients who received ATP only showed no increase in heart failure admission compared with those with no ICD therapy (HR, 0.93; 95% CI, 0.67-1.29; P = 0.7) (Fig. 2).
Inappropriate shocks and mortality
A total of 89 patients (11.5%) experienced inappropriate ICD shocks. Inappropriate shocks were not associated with increased mortality in a time-varying analysis (HR, 0.88; 95% CI, 0.53-1.47; P = 0.6), when compared with patients who had not experienced inappropriate ICD shocks in their lifetime. Of the patients receiving inappropriate shocks, 41 received no appropriate therapy (ATP or shocks), 25 received at least 1 appropriate shock, and 23 received appropriate ATP but no appropriate shocks.
Discussion
In this population-based cohort of ICD recipients, we demonstrated that increasing shock burden was associated with an increase in both mortality and heart failure hospitalizations. The threshold at which mortality was significantly increased was 2 or more lifetime ICD shocks for ventricular arrhythmia. A single lifetime ICD shock for ventricular arrhythmia increased the risk of heart failure, with incremental risk of heart failure with increasing burden. Patients who had either ATP for VT or no VT at all were at lowest risk for both mortality and heart failure hospitalization. In our cohort, inappropriate shocks alone were not associated with increased mortality risk.
Previous work by Sweeney et al.9 reported that patients with shock-terminated episodes of ventricular arrhythmia have a higher mortality risk, but did not examine the effect of shock burden on the outcomes of mortality and heart failure. Likewise, in the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT), a single appropriate shock increased the risk of death 5-fold. Additional shocks were associated with a 3-fold increased risk of death.8 Our data represent a contemporary cohort than either of these studies, albeit with conventional programming, rather than shock reduction programming, which was adopted after this study was completed.
Myocardial injury due to both transthoracic and intracardiac shocks is well established.10, 19, 20, 21 Increasing shock strength causes cardiac biomarker release, and detrimental effects on ventricular function have been demonstrated.19 Tokano et al.19 showed that ICD shocks greater than 9 J result in a 10% to 15% reduction in the cardiac index, whereas lower-energy shocks did not result in objective hemodynamic compromise. Therefore, the absence of a relationship between ATP therapy and mortality is not surprising. This has also been borne out in the literature with multiple studies observing that ATP is not associated with increased mortality risk.9 The association between shocks and objective impairment in ventricular function as well as cardiac biomarker release supports the hypothesis that the shock itself may be harmful, at least in the short term. The association between ICD shocks for ventricular arrhythmia and increased mortality also supports the hypothesis of harm. This does not, however, exclude the possibility that the presence of more advanced myocardial disease, unresponsive to pace termination, results in a worse prognosis. Therefore, it is difficult to ascertain whether it is the shock itself that is harmful versus the properties of the disease substrate and consequently the ventricular arrhythmia itself.
The effect of shock reduction programming could not be evaluated in this study, because it was not in effect at the time the study was performed. Inappropriate shocks were associated with a 2-fold increased risk of death in both the Multicenter Automatic Defibrillator Implantation Trial II (MADIT II) and Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT).7, 8 In these prior studies, the majority of inappropriate shocks were due to atrial fibrillation, which may be a marker of worse prognosis in a heart failure population.22 In our study, the majority of inappropriate shocks were due to sinus tachycardia, which may partially explain the discrepancy between our study and others that have demonstrated an association between inappropriate shocks and mortality. Likewise, Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) showed that inappropriate ICD therapy and ICD shocks were independently associated with increased mortality.23 Randomization to high-rate detection was associated with a reduced risk of mortality in this primary prevention ICD population. Patients in the conventional programming arm received a higher frequency of both appropriate and inappropriate therapies with almost twice the number of shocks seen in the high-rate and delayed treatment arms.23, 24 Conversely, neither this analysis nor that by Sweeney et al.9 showed this relationship. The Avoid Delivering Therapies for Non-sustained Arrhythmias in ICD Patients III (ADVANCE III) trial, which randomized patients to ICD programming with long detection intervals versus standard detection intervals, showed a significant decrease in the rate of total ICD therapies and of inappropriate shocks and hospitalizations, without a statistically significant difference in mortality.25 Similar results were seen in a secondary prevention population in the PainFree SST Substudy.26 Prolonged VF detection intervals were associated with lower rates of treated VF episodes and were not associated with increased syncope or mortality. Although the absence of a relationship between inappropriate shocks and mortality may argue against a direct detrimental effect of shocks, it has been hypothesized that the type of arrhythmia episode may precondition the myocardium to the adverse effect of a shock.9
Although the link between risk of heart failure and death in the ICD patient population is well established, the association between increasing risk of heart failure admission with increasing shock burden has not previously been described. Our study demonstrates a clear, incremental risk of heart failure hospitalization with increasing shock burden for ventricular arrhythmia. In MADIT II, the risk of first heart failure hospitalization increased by 90% after appropriate shocks. The risk of recurrent heart failure hospitalization increased by 74% after appropriate ICD shocks.27 Again, what remains unclear is whether shocks and increasing ventricular arrhythmia burden are a marker for disease progression or if there is a causal link. Although these associations are not proof of causation, they do support an underlying mechanism of direct myocardial injury in an already compromised myocardium increasing the subsequent risk of heart failure and subsequent ventricular arrhythmias as previously described.10
In this study, ATP therapy was associated with improved survival but not with increased admission for heart failure. Although the mechanism underlying this observation was not addressed in this study, it may reflect changes in medical therapy secondary to this intervention, thereby improving both heart failure and mortality outcomes. Alternatively, the underlying substrate responsive to ATP termination may be intrinsically different than that requiring a shock for arrhythmia termination.
Given our findings, it is important to improve understanding of whether suppression of ventricular arrhythmia using medical or ablation therapy may improve outcomes in this population. In the Ventricular Tachycardia Ablation vs Enhanced Drug Therapy In Structural Heart Disease (VANISH) trial, high rates of recurrent appropriate ICD shocks, VT storm, and mortality were observed among patients with VT that occurred despite antiarrhythmic drugs. In the group randomized to catheter ablation, there was a significant reduction in the composite outcome of death, VT storm, or appropriate ICD shock, largely driven by reductions in rates of appropriate shocks and episodes of VT storm.28 Further exploration of whether earlier intervention in patients who have ventricular arrhythmia to improve heart failure and mortality is warranted.
Study limitations
Certain limitations do apply to this analysis. This is a single-center cohort study in which data collection was limited to predetermined fields; thus, there is the possibility that other information that was not collected may have an impact on the outcomes studied, such as medication compliance, optimization of heart failure therapies, dynamic change in heart failure status, and cause of death. On the basis of the observational nature of the data, this study cannot imply causation, but only an association among shocks, mortality, and heart failure hospitalization. The burden of inappropriate shocks on mortality was not explored in this analysis. Further, these data were derived from a cohort treated before data demonstrating programming could markedly reduce inappropriate shocks; nevertheless, there was no effect of inappropriate shocks on mortality in our cohort. Device programming was not standardized in this real-world cohort, but one would not expect this to exert a significant effect on our findings as the major effect in MADIT-RIT was on ATP and inappropriate shocks, neither of which increased mortality in our study.
Further research is needed to better characterize the pathophysiologic mechanism underlying the effect of shocks on mortality and heart failure. Although shocks will continue to be an important component of sudden death prevention, it is important moving forward to continue to study and refine ICD programming strategies to minimize potential harms. It is also important for clinicians to be aware of the association between ICD shocks and risk of heart failure decompensation. Further studies of shock avoidance in the prevention of heart failure decompensation are warranted.
Conclusion
Patients who experience more than a single ICD shock have an increased risk of both mortality and heart failure hospitalization, whereas ATP alone does not increase the risk of mortality or heart failure hospitalization. Likewise, inappropriate shocks are not associated with increased mortality risk. This suggests that reduction of ventricular arrhythmia requiring shocks may alter the progression of both heart failure and mortality. This study provides important insight into the management of patients with ICDs and recurrent ventricular arrhythmia. Heart failure progression may be halted by early and aggressive treatment of ventricular arrhythmia with catheter ablation or antiarrhythmic drugs. The optimal modality of treatment remains to be determined; however, it remains crucial to institute early therapy with the potential to improve prognosis. Testing of this hypothesis in clinical trials is important to determine the true magnitude of effect. Whether ventricular arrhythmia worsens progression of heart failure or vice versa remains to be determined.
Funding Sources
This study is supported by the Cardiac Arrhythmia Network and the Nova Scotia Health Authority Research Fund.
Disclosures
Dr Sapp has received research funding from Biosense Webster and St. Jude Medical, and consulting fees/honoraria from St Jude Medical, Medtronic, and Biosense Webster. Dr AbdelWahab has received honoraria from St Jude Medical, Medtronic, and Biosense Webster. Dr Parkash has received consulting fees/honoraria/salary from Medtronic, St Jude Medical, Bayer Canada, and Pfizer Canada. The other authors report no conflicts of interest.
Footnotes
Ethics Statement: This study was approved by the research ethics board at the Queen Elizabeth II Health Sciences Center.
See page 166 for disclosure information.
References
- 1.A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias. The Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators. N Engl J Med. 1997;337:1576–1583. doi: 10.1056/NEJM199711273372202. [DOI] [PubMed] [Google Scholar]
- 2.Buxton A.E., Lee K.L., Fisher J.D. A randomized study of the prevention of sudden death in patients with coronary artery disease. Multicenter Unsustained Tachycardia Trial Investigators. N Engl J Med. 1999;341:1882–1890. doi: 10.1056/NEJM199912163412503. [DOI] [PubMed] [Google Scholar]
- 3.Connolly S.J., Gent M., Roberts R.S. Canadian implantable defibrillator study (CIDS) : a randomized trial of the implantable cardioverter defibrillator against amiodarone. Circulation. 2000;101:1297–1302. doi: 10.1161/01.cir.101.11.1297. [DOI] [PubMed] [Google Scholar]
- 4.Moss A.J., Hall W.J., Cannom D.S. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. N Engl J Med. 1996;335:1933–1940. doi: 10.1056/NEJM199612263352601. [DOI] [PubMed] [Google Scholar]
- 5.Moss A.J., Zareba W., Hall W.J. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002;346:877–883. doi: 10.1056/NEJMoa013474. [DOI] [PubMed] [Google Scholar]
- 6.Bardy G.H., Lee K.L., Mark D.B. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med. 2005;352:225–237. doi: 10.1056/NEJMoa043399. [DOI] [PubMed] [Google Scholar]
- 7.Daubert J.P., Zareba W., Cannom D.S. Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact. J Am Coll Cardiol. 2008;51:1357–1365. doi: 10.1016/j.jacc.2007.09.073. [DOI] [PubMed] [Google Scholar]
- 8.Poole J.E., Johnson G.W., Hellkamp A.S. Prognostic importance of defibrillator shocks in patients with heart failure. N Engl J Med. 2008;359:1009–1017. doi: 10.1056/NEJMoa071098. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Sweeney M.O., Sherfesee L., DeGroot P.J., Wathen M.S., Wilkoff B.L. Differences in effects of electrical therapy type for ventricular arrhythmias on mortality in implantable cardioverter-defibrillator patients. Heart Rhythm. 2010;7:353–360. doi: 10.1016/j.hrthm.2009.11.027. [DOI] [PubMed] [Google Scholar]
- 10.Hurst T.M., Hinrichs M., Breidenbach C., Katz N., Waldecker B. Detection of myocardial injury during transvenous implantation of automatic cardioverter-defibrillators. J Am Coll Cardiol. 1999;34:402–408. doi: 10.1016/s0735-1097(99)00194-1. [DOI] [PubMed] [Google Scholar]
- 11.Epstein A.E., Kay G.N., Plumb V.J., Dailey S.M., Anderson P.G. Gross and microscopic pathological changes associated with nonthoracotomy implantable defibrillator leads. Circulation. 1998;98:1517–1524. doi: 10.1161/01.cir.98.15.1517. [DOI] [PubMed] [Google Scholar]
- 12.Tereshchenko L.G., Faddis M.N., Fetics B.J. Transient local injury current in right ventricular electrogram after implantable cardioverter-defibrillator shock predicts heart failure progression. J Am Coll Cardiol. 2009;54:822–828. doi: 10.1016/j.jacc.2009.06.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Schron E.B., Exner D.V., Yao Q. Quality of life in the antiarrhythmics versus implantable defibrillators trial: impact of therapy and influence of adverse symptoms and defibrillator shocks. Circulation. 2002;105:589–594. doi: 10.1161/hc0502.103330. [DOI] [PubMed] [Google Scholar]
- 14.Herbst J.H., Goodman M., Feldstein S., Reilly J.M. Health-related quality-of-life assessment of patients with life-threatening ventricular arrhythmias. Pacing Clin Electrophysiol. 1999;22:915–926. doi: 10.1111/j.1540-8159.1999.tb06816.x. [DOI] [PubMed] [Google Scholar]
- 15.Irvine J., Dorian P., Baker B. Quality of life in the Canadian Implantable Defibrillator Study (CIDS) Am Heart J. 2002;144:282–289. doi: 10.1067/mhj.2002.124049. [DOI] [PubMed] [Google Scholar]
- 16.Yee R., Verma A., Beardsall M. Canadian Cardiovascular Society/Canadian Heart Rhythm Society joint position statement on the use of remote monitoring for cardiovascular implantable electronic device follow-up. Can J Cardiol. 2013;29:644–651. doi: 10.1016/j.cjca.2012.11.036. [DOI] [PubMed] [Google Scholar]
- 17.Cox J.L. Optimizing disease management at a health care system level: the rationale and methods of the improving cardiovascular outcomes in Nova Scotia (ICONS) study. Can J Cardiol. 1999;15:787–796. [PubMed] [Google Scholar]
- 18.Parkash R., Sapp J.L., Basta M. Use of primary prevention implantable cardioverter-defibrillators in a population-based cohort is associated with a significant survival benefit. Circ Arrhythm Electrophysiol. 2012;5:706–713. doi: 10.1161/CIRCEP.112.970798. [DOI] [PubMed] [Google Scholar]
- 19.Tokano T., Bach D., Chang J. Effect of ventricular shock strength on cardiac hemodynamics. J Cardiovasc Electrophysiol. 1998;9:791–797. doi: 10.1111/j.1540-8167.1998.tb00118.x. [DOI] [PubMed] [Google Scholar]
- 20.Runsio M., Kallner A., Kallner G., Rosenqvist M., Bergfeldt L. Myocardial injury after electrical therapy for cardiac arrhythmias assessed by troponin-T release. Am J Cardiol. 1997;79:1241–1245. doi: 10.1016/s0002-9149(97)00090-8. [DOI] [PubMed] [Google Scholar]
- 21.Stoddard M.F., Labovitz A.J., Stevens L.L. Effects of electrophysiologic studies resulting in electrical countershock or burst pacing on left ventricular systolic and diastolic function. Am Heart J. 1988;116:364–370. doi: 10.1016/0002-8703(88)90607-2. [DOI] [PubMed] [Google Scholar]
- 22.Dries D.L., Exner D.V., Gersh B.J. Atrial fibrillation is associated with an increased risk for mortality and heart failure progression in patients with asymptomatic and symptomatic left ventricular systolic dysfunction: a retrospective analysis of the SOLVD trials. Studies of Left Ventricular Dysfunction. J Am Coll Cardiol. 1998;32:695–703. doi: 10.1016/s0735-1097(98)00297-6. [DOI] [PubMed] [Google Scholar]
- 23.Ruwald A.C., Schuger C., Moss A.J. Mortality reduction in relation to implantable cardioverter defibrillator programming in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) Circ Arrhythm Electrophysiol. 2014;7:785–792. doi: 10.1161/CIRCEP.114.001623. [DOI] [PubMed] [Google Scholar]
- 24.Moss A.J., Schuger C., Beck C.A. Reduction in inappropriate therapy and mortality through ICD programming. N Engl J Med. 2012;367:2275–2283. doi: 10.1056/NEJMoa1211107. [DOI] [PubMed] [Google Scholar]
- 25.Gasparini M., Proclemer A., Klersy C. Effect of long-detection interval vs standard-detection interval for implantable cardioverter-defibrillators on antitachycardia pacing and shock delivery: the ADVANCE III randomized clinical trial. JAMA. 2013;309:1903–1911. doi: 10.1001/jama.2013.4598. [DOI] [PubMed] [Google Scholar]
- 26.Sterns L.D., Meine M., Kurita T. Extended detection time to reduce shocks is safe in secondary prevention patients: the secondary prevention substudy of PainFree SST. Heart Rhythm. 2016;13:1489–1496. doi: 10.1016/j.hrthm.2016.03.022. [DOI] [PubMed] [Google Scholar]
- 27.Goldenberg I., Moss A.J., Hall W.J. Causes and consequences of heart failure after prophylactic implantation of a defibrillator in the multicenter automatic defibrillator implantation trial II. Circulation. 2006;113:2810–2817. doi: 10.1161/CIRCULATIONAHA.105.577262. [DOI] [PubMed] [Google Scholar]
- 28.Sapp J.L., Wells G.A., Parkash R. Ventricular tachycardia ablation versus escalation of antiarrhythmic drugs. N Engl J Med. 2016;375:111–121. doi: 10.1056/NEJMoa1513614. [DOI] [PubMed] [Google Scholar]


