Skip to main content
Indian Pacing and Electrophysiology Journal logoLink to Indian Pacing and Electrophysiology Journal
editorial
. 2020 Mar 7;20(2):47–48. doi: 10.1016/j.ipej.2020.03.002

Cell phone based ECG monitoring: Old wine in new bottle, or something better?

Aparna Jaswal 1,, Anil Saxena 1
PMCID: PMC7082672  PMID: 32156638

“You never change things by fighting the existing reality.

To change something, build a new model that makes the existing model obsolete.”

Buckminster Fuller

Norman “Jeff” Holter in his pioneering work led to the first prototype of “mobile” cardiac telemetry device, requiring 85 pounds of equipment, worn on his back while riding a stationary bicycle and used a radio-ECG [[1], [2], [3]]. Developments in miniaturization of instrumentation, evolution of microprocessors and wireless networking technologies have acted in concert to make his vision a reality. Mobile ECG monitoring is about to revolutionize the way we diagnose cardiac rhythm disorders [4].

Several features distinguish the modern ambulatory electrocardiography (AECG) devices and make them extremely useful. These novel devices allow us to continuously monitor an ECG (beat-to-beat) almost real time, in addition to automatic arrhythmia detection and wireless transmission of data. These features play a critical role in improving the diagnostic yield while also enhancing arrhythmia detection [[5], [6], [7], [8], [9], [10], [11], [12]]. Nevertheless, challenges persist for both manufacturers and clinicians to provide reliability and functionality, along with ability to analyze and store large amounts of data securely.

The two studies published in this issue [13,14] have compared the Holter monitoring and traditional ECG recording with new devices utilizing mobile phone based protocols for recording and analyzing ECG. While WebCardio records 2 channel ambulatory ECG up to 72 h, SanketLife has the ability to support up to 12 leads of ECG and a short rhythm strip.

In the first study, the authors concluded that WebCardio performed better in P wave identification compared to conventional Holter mainly due to higher degree of signal noise from Holter cables which deteriorate over time [13]. The study stands out for its simplicity, generating inferences of high utility in routine clinical practice. The Web Cardio performed comparably well to the Holter in identifying arrhythmias. However when PVC and first degree AV Block were included, Web Cardio had an overall higher sensitivity in identifying arrhythmias, though not statistically significant.

In the second study, Kumar et al. [14] utilised SanketLife as a low cost, portable, pocket sized 12 lead ECG mechanised by SanketLife app running on compatible iOS & android phones that connect wirelessly via blue-tooth technology to the device. Due to its ability to record a 12 lead ECG it can be used to detect ischemia. Misdiagnosis or late diagnosis of acute coronary syndromes is quite common in Indian patients. Though several new options such as wearable and non-wearable devices are being explored across geographies to optimise healthcare delivery and ensure early diagnosis, published biomedical literature about the accuracy and reliability of these devices is still sparse. In this context, this prospective study aimed to establish the diagnostic accuracy of SanketLife against standard 12 lead ECG in the detection of cardiovascular pathology. Amongst the 91 pts studied, both modalities were equally sensitive in diagnosing ST segment elevation, hyperacute T waves & AV Block. However, there was a lack of agreement in a few cases of APCs & VPCs. The utility of the device in accurate diagnosis of AF was also documented, a fact that holds great promise.

The above studies add to the scant literature on these newer generation ECG monitoring devices. The fact that these devices were found comparable or better to traditional ones is not surprising, given that they basically perform same task, and differ only in physical design, lead position, wireless transfer of data, and app based processing utilizing mobile phones. In fact, they represent a paradigm shift in ECG monitoring similar to the point when development in microelectronics enabled development of portable ECG machines and Holter monitors. A major advantage of these devices is increased convenience and widespread usage as very little equipment is needed at point of care. Moreover, being in digital format, the ECG can be transmitted to physicians for quick interpretation.

From the pioneering work of Dr. Norman J. Holter [3] ambulatory ECG monitoring has evolved to include numerous novel devices that provide a wide array of recording options. The quality of signal processing and interpretation of ECG will continue to improve through increased processing power, machine learning and artificial intelligence. The type of patient and clinical indication will dictate which device and recording options are most appropriate in a given situation.

Declaration of competing interest

None.

Footnotes

Peer review under responsibility of Indian Heart Rhythm Society.

References

  • 1.Mar B.D. The history of clinical Holter monitoring. Ann Noninvasive Electrocardiol. 2005;10(2):226–230. doi: 10.1111/j.1542-474X.2005.10202.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Kennedy H.L. The history, science, and innovation of Holter technology. Ann Noninvasive Electrocardiol. 2006;11(1):85–94. doi: 10.1111/j.1542-474X.2006.00067.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Holter N.J. New method for heart studies: continuous electrocardiography of active subjects over long periods is now practical. Science. 1961;134(3486):1214–1220. doi: 10.1126/science.134.3486.1214. [DOI] [PubMed] [Google Scholar]
  • 4.Soundarapandian K., Berarducci M. 2009. Analog Front-End Design for ECG Systems Using Delta-Sigma Adcs.http://www.ti.com/lit/an/sbaa160a/sbaa160a.pdf [Google Scholar]
  • 5.Charitos E.I., Stierle U., Ziegler P.D., Baldewig M., Robinson D.R., Sievers H.-H. A comprehensive evaluation of rhythm monitoring strategies for the detection of atrial fibrillation recurrence: insights from 647 continuously monitored patients and implications for monitoring after therapeutic interventions. Circulation. 2012;126(7):806–814. doi: 10.1161/CIRCULATIONAHA.112.098079. [DOI] [PubMed] [Google Scholar]
  • 6.Hanke T., Charitos E.I., Stierle U., Karluss A., Kraatz E., Graf B. Twenty-four–hour Holter monitor follow-up does not provide accurate heart rhythm status after surgical atrial fibrillation ablation therapy: up to 12 months experience with a novel permanently implantable heart rhythm monitor device. Circulation. 2009;120(11_suppl_1):S177–S184. doi: 10.1161/CIRCULATIONAHA.108.838474. [DOI] [PubMed] [Google Scholar]
  • 7.Locati E., Moya A., Oliveira M., Tanner H., Willems R., Lunati M. External prolonged electrocardiogram monitoring in unexplained syncope and palpitations: results of the SYNARR-Flash study. Ep Europace. 2016;18(8):1265–1272. doi: 10.1093/europace/euv311. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Mittal S., Movsowitz C., Steinberg J.S. Ambulatory external electrocardiographic monitoring: focus on atrial fibrillation. J Am Coll Cardiol. 2011;58(17):1741–1749. doi: 10.1016/j.jacc.2011.07.026. [DOI] [PubMed] [Google Scholar]
  • 9.Reiffel J.A., Schwarzberg R., Murry M. Comparison of autotriggered memory loop recorders versus standard loop recorders versus 24-hour Holter monitors for arrhythmia detection. Am J Cardiol. 2005;95(9):1055–1059. doi: 10.1016/j.amjcard.2005.01.025. [DOI] [PubMed] [Google Scholar]
  • 10.Rosenberg M.A., Samuel M., Thosani A., Zimetbaum P.J. Use of a noninvasive continuous monitoring device in the management of atrial fibrillation: a pilot study. Pacing Clin Electrophysiol. 2013;36(3):328–333. doi: 10.1111/pace.12053. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Rothman S.A., Laughlin J.C., Seltzer J., Walia J.S., Baman R.I., Siouffi S.Y. The diagnosis of cardiac arrhythmias: a prospective multi-center randomized study comparing mobile cardiac outpatient telemetry versus standard loop event monitoring. J Cardiovasc Electrophysiol. 2007;18(3):241–247. doi: 10.1111/j.1540-8167.2006.00729.x. [DOI] [PubMed] [Google Scholar]
  • 12.Vasamreddy C.R., Dalal D., Dong J., Cheng A., Spragg D., Lamiy S.Z. Symptomatic and asymptomatic atrial fibrillation in patients undergoing radiofrequency catheter ablation. J Cardiovasc Electrophysiol. 2006;17(2):134–139. doi: 10.1111/j.1540-8167.2006.00359.x. [DOI] [PubMed] [Google Scholar]
  • 13.Karunadas C.P., Mathew C. Comparison of arrhythmia detection by conventional Holter and a novel ambulatory ECG system using patch and Android App, over 24 hour period. Indian Pacing Electrophysiol J. 2020;20(2):49–53. doi: 10.1016/j.ipej.2019.12.013. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Kumar S., Nagesh C., Singh M., Pandian A., Khan B., Delurgio D. Assessment of diagnostic accuracy of SanketLife–A Wireless, pocket-sized ECG Biosensor, in comparison to standard 12 lead ECG in the detection of cardiovascular diseases in a tertiary care setting. Indian Pacing Electrophysiol J. 2020;20(2):54–59. doi: 10.1016/j.ipej.2019.12.011. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Indian Pacing and Electrophysiology Journal are provided here courtesy of Elsevier