Abstract
Indoor air quality (IAQ) has begun to surface as an important issue that affects the comfort and health of people; however, there is little research concerned about the IAQ monitoring of hotels up to now. Hotels are designed to provide comfortable spaces for guests. However, most complaints related to uncomfortable thermal environment and inadequate indoor air quality appear. In addition, microbial pollution can affect the health of tourists such as the Legionnaire’s disease and SARS problems. This study is aimed to establish the comprehensive IAQ audit approach for hotel buildings with portable equipments, and one five-star international hotel in Taiwan was selected to exam this integrated approach. Finally, four major problems are identified after the comprehensive IAQ audit. They are: (1) low room temperature (21.8°C), (2) insufficient air exchange rate (<1.5 h−1), (3) formaldehyde contamination (>0.02 ppm), and (4) the microbial pollution (total bacteria: 2,624–3,799 CFU/m3). The high level of formaldehyde may be due to the emission from the detergent and cleaning agents used for housekeeping.
Keywords: Indoor air quality (IAQ), Hotel building, Tourist health
References
- Bholah R., Fagoonee I., Subratty H. Sick building syndrome in Mauritius: Are symptoms associated with the office environment. Indoor and Built Environment. 2000;9:44–51. [Google Scholar]
- Bohdanowicz, P., & Martinac, I. M. (2002). Thermal comfortable and energy saving in the hotel industry. Paper Presentef at the AMS 15th Conference on Biometeorology and Aerobiology & 16th International Congress on Biometeorology, Kansas City.
- Chien G. C. L., Law R. The impact of the severe acute respiratory syndrome on hotels: A case study of Hong Kong. International Journal of Hospitality Management. 2003;22:327–332. doi: 10.1016/S0278-4319(03)00041-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Dally K., Hanrahan P., Woodbury A., Kanarek S. Formaldehyde exposure in non-occupational environments. Archives of Environmental Health. 1981;36:277–284. doi: 10.1080/00039896.1981.10667638. [DOI] [PubMed] [Google Scholar]
- EPA (Environmental Protection Administration) Outdoor Air Quality Standards of Taiwan. Taiwan, R.O.C.: EPA; 2004. [Google Scholar]
- EPA (Environmental Protection Administration) Indoor Air Quality Standards of Taiwan. Taiwan, R.O.C.: EPA; 2005. [Google Scholar]
- European Commission . Eurobarometer: Public Opinion in the European Community. Brussels: European Commission; 2000. [Google Scholar]
- Garrett H., Hooper A., Hooper M., Rayment R., Abramson J. Increase risk of allergy in children due to formaldehyde exposure in homes. Allergy. 1999;54:330–337. doi: 10.1034/j.1398-9995.1999.00763.x. [DOI] [PubMed] [Google Scholar]
- Indoor Air Quality Management Group . A Guide on Indoor Air Quality Certification Scheme for Offices and Public Places. China: The Government of the Hong Kong Special Administrative Region; 2003. [Google Scholar]
- International Agency for Research on Cancer (IARC) Formaldehyde: IARC monographs on the evaluation of carcinogenic risks to human. Wood Dust and Formaldehyde. 1995;62:217–362. [Google Scholar]
- Jantunen M. When and where are people exposed to pollutants. In: Olli S., Jorma S., editors. Proceedings of Healthy Buildings 2000: Exposure, Human Responses and Building Investigations Proceedings. Helsinki: SIY; 2000. pp. 15–22. [Google Scholar]
- Jowaheer V., Subratty A. H. Multiple logistic regression modeling substantiates multifactor contributions associated with sick building syndrome in residential interiors in Mauritius. International Journal of Environmental Health Research. 2003;13:71–80. doi: 10.1080/0960312021000063296. [DOI] [PubMed] [Google Scholar]
- Lane G., Ferrari A., Dreher H. M. Legionnaire’s disease: A current update. Medsurg Nursing. 2004;13:409–414. [PubMed] [Google Scholar]
- Li Y., Huang X., Yu I., Wong T., Qian H. Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong. Indoor Air. 2005;15:83–95. doi: 10.1111/j.1600-0668.2004.00317.x. [DOI] [PubMed] [Google Scholar]
- Mendell J. Non-specific symptoms in office workers: A review and summary of the epidemiologic literature. Indoor Air. 1993;3:227–236. doi: 10.1111/j.1600-0668.1993.00003.x. [DOI] [Google Scholar]
- Mendell M., Smith A. Consistent pattern of elevated symptoms in air-conditioned office buildings: A reanalysis of epidemiologic studies. America Journal of Public Health. 1990;80:1193–1199. doi: 10.2105/AJPH.80.10.1193. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Morey R., Shattuck E. Role of ventilation in the causation of building-associated illnesses. Occupational Medicine: State of the Art Review. 1989;4:625–642. [PubMed] [Google Scholar]
- Olesen W. International standards for the indoor environment. Indoor Air. 2004;14:18–26. doi: 10.1111/j.1600-0668.2004.00268.x. [DOI] [PubMed] [Google Scholar]
- Rada J. Designing and building eco-efficient hotels. Green Hotelier: Magazine of the International Hotels Environmental Initiative. 1996;4:10–11. [Google Scholar]
- Radun D., Niedrig M., Ammon A., Stark K. SARS: Retrospective cohort study among German guests of the Hotel ‘M’, Hong Kong. European Communicable Disease Bulletin. 2003;8:228–230. doi: 10.2807/esm.08.12.00436-en. [DOI] [PubMed] [Google Scholar]
- Sardinas V., Most S., Guilietti A., Honchar P. Health effects associated with urea-formaldehyde foam insulation in Connecticut. Journal Environmental Health. 1979;41:453–463. [Google Scholar]
- Singh J. Health, comfort and productivity in the indoor environment. Indoor and Built Environment. 1996;5:22–33. doi: 10.1177/1420326X9600500105. [DOI] [Google Scholar]
- Stipanuk D. M. Hotels’ energy management in 2000 and beyond: Operational options that reduce use and cost. Cornell Hotel and Restaurant Administration Quarterly. 2001;42:57–70. doi: 10.1016/S0010-8804(01)81025-9. [DOI] [Google Scholar]
- Su J., Chiang M. Guidelines for Good Indoor Air Quality in Office Building in Taiwan. Taiwan, R.O.C.: Environmental Protection Administration; 2004. [Google Scholar]
- Swenberg A., Gross A., Martin J., Popp A. Formaldehyde Toxicity. New York: Hemisphere; 1983. [Google Scholar]
- Teeters K., Jones T., Boatman J. F. The future of indoor air quality: Legal and economic implications. Cornell Hotel and Restaurant Administration Quarterly. 1995;36(2):43–49. doi: 10.1177/001088049503600224. [DOI] [Google Scholar]
- The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Ventilation for Acceptable Indoor Air Quality ASHRAE Standard 62–2001. USA: American Society of Heating and Air Conditioning Engineers Inc; 2001. [Google Scholar]
- The International Hotel & Restaurant Association (IH&RA) (2002). Environmental Award. Retrieved November 10, 2004, from http://www.ih-ra.com/awards/,. accessed
- Wargocki P., Wyon P., Baik K. Perceived air quality, sick building syndrome symptoms and productivity in an office with two different pollution loads. Indoor Air. 1999;9:165–179. doi: 10.1111/j.1600-0668.1999.t01-1-00003.x. [DOI] [PubMed] [Google Scholar]
- World Health Organization (WHO) Indoor Air Pollutants: Exposure and Health Effects. EURO Reports and Studies, No.78. Copenhagen: WHO Regional Office for Europe; 1983. [Google Scholar]
- World Health Organization (WHO) Air Quality Guidelines for Europe. Geneva: WHO; 1999. [Google Scholar]
- World Health Organization (WHO) International Travel and Health. Geneva: WHO; 2005. [Google Scholar]
- Wu P. C., Li Y. Y., Lee C. C., Chiang C. M., Su H. J. J. Risk assessment of formaldehyde in typical office buildings in Taiwan. Indoor Air. 2003;13:359–363. doi: 10.1111/j.1600-0668.2003.00205.x. [DOI] [PubMed] [Google Scholar]
- Zweers T., Preller L., Brunekreef B., Boleij J. S. M. Health and indoor climate complaints of 7043 office workers in 61 buildings in the Netherlands. Indoor Air. 1992;2:127–136. doi: 10.1111/j.1600-0668.1992.00001.x. [DOI] [Google Scholar]