Increase in lung volume originated by extrinsic PEEP in patients with auto-PEEP

The role of static lung complicance

E Fernández Mondéjar 1, G Vazquez Mata 1, P Navarrete Navarro 1, R Rivera Fernández 1, J M Torres Ruiz 1, E Carzo 1
PMCID: PMC7094972  PMID: 1527256

Abstract

The use of extrinsic positive end expiratory pressure (PEEPe) in patients with auto-PEEP (AP) can reduce the respiratory work during weaning from mechanical ventilation. However, the application of PEEPe produce a certain level of hyperinflation, an undesirable effect which can limit the efficacy of the reduction of respiratory work. The objective of the present study has been to determine if the encrease in end expiratory lung volume (EELV) originated by the PEEPe is related to static lung compliance (SLC). We have studied 14 patients on mechanical ventilation in whom an AP of between 4 and 12 cmH2O was detected. On applying PEEPe equal to half the AP, the EELV increased slightly (77±64 ml) and was not related to pulmonary compliance. When PEEPe equal to the AP was applied, the EELV increased by 178±110 ml (range 45–375 ml,p<0.05), and there was a significant correlation with SLC (r=0.659,p<0.05). In conclusion, the application of PEEPe equal to the AP causes a moderate increace in EELV. However, in patients with high pulmonary compliance this increase can be more important and must be taken into account when considering the use of PEEPe during weaning.

Key words: Mechanical ventilation, Auto-PEEP, Pulmonary compliance

References

  • 1.Pepe PE, Marini JJ. Occult positive end expiratory pressure in mechanically ventilated patients with airflow obstruction. The auto-PEEP effect. Am Rev Respir Dis. 1982;126:166–170. doi: 10.1164/arrd.1982.126.1.166. [DOI] [PubMed] [Google Scholar]
  • 2.Broseghini C, Brandolese R, Poggi R, Polese G, Manzin E, Milic-Emili J, Rossi A. Respiratory mechanics during first day of mechanical ventilation in patients with pulmonary edema and chronic airway obstruction. Am Rev Respir Dis. 1988;138:355–361. doi: 10.1164/ajrccm/138.2.355. [DOI] [PubMed] [Google Scholar]
  • 3.Haluszka J, Chartrand DA, Grassino AE, Milic-Emili J. Intrinsic PEEP and arterial PCO2 in stable patients with chronic obstructive pulmonary disease. Am Rev Respir Dis. 1990;141:1194–1197. doi: 10.1164/ajrccm/141.5_Pt_1.1194. [DOI] [PubMed] [Google Scholar]
  • 4.Smith TC, Marini JJ. Impact of PEEP on lung mechanics and work of breathing in severe airflow obstruction. J Appl Physiol. 1988;65:1488–1499. doi: 10.1152/jappl.1988.65.4.1488. [DOI] [PubMed] [Google Scholar]
  • 5.Petrof BJ, Legaré M, Goldberg P, Milic-Emili J, Gottfried BS. Continous positive airway pressure reduces work of breathing and dyspnea during weaning from mechanical ventilation in severe chronic obstructive pulmonary disease. Am Rev Respir Dis. 1990;141:281–289. doi: 10.1164/ajrccm/141.2.281. [DOI] [PubMed] [Google Scholar]
  • 6.Roussos C, Macklem PT. The respiratory muscles. N Eng J Med. 1982;307:786–797. doi: 10.1056/NEJM198209233071304. [DOI] [PubMed] [Google Scholar]
  • 7.Penguelly LD, Alderson AM, Milic-Emili J. Mechanics of the diaphragm. J Appl Physiol. 1971;30:797–895. doi: 10.1152/jappl.1971.30.6.797. [DOI] [PubMed] [Google Scholar]
  • 8.Gay PC, Rodarte JR, Hubmayr RD. The effects of positive expiratory pressure on isovolume flow and dynamic hyperinflation in patients receiving mechanical ventilation. Am Rev Respir Dis. 1989;139:621–626. doi: 10.1164/ajrccm/139.3.621. [DOI] [PubMed] [Google Scholar]
  • 9.Fernandez R, Mancebo J, Blanch Ll, Benito S, Calaf N, Net A. Intrinsic PEEP on static pressure-volume curves. Intensive Care Med. 1990;16:233–236. doi: 10.1007/BF01705157. [DOI] [PubMed] [Google Scholar]
  • 10.Gattinoni L, Mascheroni D, Basilico E, Foti G, Presenti A, Avalli L. Volume/pressure curve of total respiratory system in paralysed patients: artefacts and correction factors. Intensive Care Med. 1987;13:19–25. doi: 10.1007/BF00263552. [DOI] [PubMed] [Google Scholar]
  • 11.Bishop B, Hirsh J, Thursby M. Volume, flow, and timing of each breath during positive pressure breathing in man. J Appl Physiol. 1978;45:495–501. doi: 10.1152/jappl.1978.45.4.495. [DOI] [PubMed] [Google Scholar]

Articles from Intensive Care Medicine are provided here courtesy of Nature Publishing Group

RESOURCES