The authors wish to make a change to the published paper [1]. In the original manuscript, there are mistakes in the headers of columns six and seven in Table 1. The corrected Table 1 is presented below.
Table 1.
Water Source | Analyte a | Intra-Day Recovery (RSD b, %, n = 3) | Inter-Day Recovery | LOD C | LOQ d | ||
---|---|---|---|---|---|---|---|
I | II | III | (RSD, %, n = 9) | (µg L−1) | (µg L−1) | ||
River | CSA | 74.7 (3.7) | 65.9 (4.5) | 75.7 (3.2) | 72.1 (7.3) | 2.0 | 6.5 |
CSB | 77.2 (3.6) | 72.1 (3.8) | 72.1 (1.9) | 73.8 (4.6) | 1.5 | 5.0 | |
PMB | 83.7 (3.2) | 76.9 (9.7) | 83.6 (1.4) | 81.4 (6.3) | 1.0 | 3.0 | |
Spring | CSA | 72.3 (2.1) | 71.6 (4.7) | 76.8 (1.2) | 73.6 (4.2) | 1.0 | 3.0 |
CSB | 74.6 (2.2) | 81.8 (3.9) | 74.4 (3.0) | 76.9 (5.5) | 1.0 | 3.0 | |
PMB | 85.5 (5.3) | 83.1 (4.3) | 80.9 (10.2) | 83.2 (6.4) | 1.0 | 3.0 | |
Lake | CSA | 83.1 (3.9) | 84.4 (6.2) | 86.4 (9.5) | 84.6 (6.3) | 2.0 | 6.0 |
CSB | 85.6 (3.7) | 86.7 (2.3) | 85.1 (3.6) | 85.8 (3.1) | 1.5 | 5.0 | |
PMB | 83.8 (3.1) | 90.1 (1.8) | 84.5 (2.3) | 86.2 (4.0) | 1.0 | 3.0 |
a Colistin A (CSA); colistin B (CSB); polymyxin B (PMB); b relative standard deviation (RSD); c limit of detection (LOD); d limit of quantification (LOQ).
The authors apologize for any inconvenience caused and the change does not affect the scientific results. The manuscript will be updated, and the original will remain online on the article webpage at https://www.mdpi.com/2073-4360/12/1/131.