Abstract
The performance of the vortex tube is low compared to a conventional heat pump engine based on Freon refrigerants, and therefore, there is a need for an experiment on how to improve its efficiency. This data article aims to analyze the effect of the new vortex tube design on cold temperature (Tc), hot temperature (Th), delta cold temperature (ΔTc), delta hot temperature (ΔTh), heat transferred as cooling effect , heat transferred as heating effect , isentropic efficiency as cooling effect (ηisc), isentropic efficiency as heating effect (ηisc), the coefficient of performance refrigeration (COPref), and coefficient of performance heat pump (COPh), which is tested based on pressure and fraction variations. The data were obtained from the experimental measurements. Data were collected at conditions with temperature controlled at 27 ± 0.1°C. All measuring instruments were supposed to be consistent for at least 5 min for data to be collected, although retrieval was conducted 4 times.
Keywords: Coefficient of the performance (COP), experiment, heat flow, isentropic efficiency, mathematical analysis
Specifications Table
| Subject | Engineering, Mechanical Engineering |
| Specific subject area | Heat transfer, Fluid dynamics, Thermodynamics, Heat and mass transfer, Thermophysical property measurement, Cryogenics, Counter-flow Ranque-Hilsch Vortex Tube, Heat Pump. |
| Type of data | Table Image Figure |
| How data were acquired | Data were collected from the experimental measurements and mathematical calculations. Measuring instruments used include pressure gauge, flowmeter (air), anemometer, thermocouple, flowmeter (water), and data acquisition. For mathematical calculations using a personal computer with Microsoft Office Excel software. |
| Data format | Raw Data |
| Parameters for data collection | The parameters for experimental data include the temperature of the air to the inlet, room air, air from hot and cold outlets, and water to the cooling tube. It also included the volume of the airflow rate to the inlet, the pressure of the air entering the channel to the inlet, maximum air velocity from cold outlet, testing air velocity of nth-testing from cold outlet, and cooling water flow rate volume. |
| Description of data collection | Data were collected based on the conditions of the test chamber, whose temperature was controlled at 27 ± 0.1°C. The data were taken in case all measuring instruments were consistent at least 5 minutes. Data Retrieval was carried out 4 times. |
| Data source location | Department of Mechanical Engineering Education, Universitas Sebelas Maret City/Town/Region: Central Java Province Country: Indonesia |
| Data accessibility | With the article |
| Related research article | Sarifudin, A., Wijayanto, D.S., Widiastuti, I, Parameters optimization of tube type, pressure, and mass fraction on vortex tube performance using the Taguchi method. International Journal of Heat and Technology, https://doi.org/10.18280/ijht.370230 |
Value of the data
-
•
The data describes comprehensive RHVT thermal performance on the new vortex tube design tested based on pressure and fraction variations.
-
•
The data illustrates the design specifications of the new vortex tube design to improve their performance.
-
•
The data describes the installation procedures and working specifications of the measuring instruments to determine the performance on the vortex tube.
-
•
The data provides calculation procedures for mathematical analysis of the experimental measurement.
1. Data Description
The performance of the vortex tube is low compared to a conventional heat pump engine based on Freon refrigerants, and therefore, there is a need for an experiment on how to improve its efficiency. Furthermore, the vortex tube has several benefits, including no moving parts or mechanical wear, saving maintenance costs, no Freon use, and it is environmentally friendly [1,2]. According to previous studies, the parameters that might improve its performance include mass fraction, air pressure entering the inlet, material type, and geometry [3], [4], [5], [6], [7]. This experiment, therefore, aims to determine the best vortex tube performance parameters tested under variations in design, pressure and fraction. The performance dataset presented includes cold temperature (Tc), hot temperature (Th), delta cold temperature (ΔTc), delta hot temperature(ΔTh), heat transferred as cooling effect , heat transferred a heating effect , isentropic efficiency as cooling effect (ηisc), isentropic efficiency as heating effect (ηisc), coefficient of performance refrigeration (COPref), and coefficient of performance heat pump (COPh).
The average temperature of cold air produced by vortex tubes with natural cooling tube types is presented in Table 1 while Table 2 shows the vortex tubes with forced cooling. Temperature data are presented using °C units.
Table 1.
Temperature average air exits from the natural cooling vortex tube cold outlet.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 21.650°C | 18.250°C | 15.850°C |
| 40% | 21.100°C | 17.350°C | 14.925°C |
| 50% | 21.900°C | 18.650°C | 16.375°C |
| 60% | 22.350°C | 19.375°C | 17.300°C |
| 70% | 22.825°C | 20.175°C | 18.350°C |
Table 2.
Temperature of the mean air exit from the vortex tube cold outlet and forced cooling.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 20.600°C | 16.600°C | 13.950°C |
| 40% | 20.200°C | 16.050°C | 13.450°C |
| 50% | 20.400°C | 16.450°C | 14.000°C |
| 60% | 20.600°C | 16.850°C | 14.575°C |
| 70% | 20.975°C | 17.675°C | 15.925°C |
The average temperature of hot air produced by vortex tubes with natural cooling tube types is presented in Table 3, while Table 4 shows the vortex tubes with forced cooling. Temperature data are presented using °C units.
Table 3.
Temperature average air exits from the natural cooling vortex tube heat outlet.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 29.300°C | 30.075°C | 30.500°C |
| 40% | 30.550°C | 31.800°C | 32.550°C |
| 50% | 32.500°C | 35.050°C | 36.650°C |
| 60% | 34.900°C | 38.975°C | 41.000°C |
| 70% | 32.500°C | 35.750°C | 37.850°C |
Table 4.
Temperature of the mean air exit from the vortex tube heat outlet and forcible cooling.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 27.400°C | 27.550°C | 27.650°C |
| 40% | 28.025°C | 28.575°C | 28.975°C |
| 50% | 28.325°C | 29.050°C | 29.600°C |
| 60% | 28.575°C | 29.550°C | 30.250°C |
| 70% | 28.050°C | 28.650°C | 29.050°C |
Changes in the cold (ΔTc) or hot air temperature (ΔTh) is the difference in inlet temperature (Ti) to cold outlet temperature (Tc) or hot outlet temperature (Th), as shown in equation [8]
| (1) |
| (2) |
The changes in the cold temperature (ΔTc) of cold air produced by vortex tubes with natural cooling tube types is presented in Table 5 while Table 6 shows the vortex tubes with forced cooling. Temperature data are presented using °C units.
Table 5.
Average changes in the cold temperature of air coming out of the natural cooling vortex tube cooling outlet.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 5.350°C | 8.750°C | 11.150°C |
| 40% | 5.900°C | 9.650°C | 12.075°C |
| 50% | 5.100°C | 8.350°C | 10.625°C |
| 60% | 4.650°C | 7.625°C | 9.700°C |
| 70% | 4.175°C | 6.825°C | 8.650°C |
Table 6.
Changes in the cold temperature mean air exits from the vortex tube cold forced cooling outlet.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 6.400°C | 10.400°C | 13.050°C |
| 40% | 6.800°C | 10.950°C | 13.550°C |
| 50% | 6.600°C | 10.550°C | 13.000°C |
| 60% | 6.400°C | 10.150°C | 12.425°C |
| 70% | 6.025°C | 9.325°C | 11.075°C |
The hot air temperature (ΔTh) of hot air produced by vortex tubes with natural cooling tube types is presented in Table 7 while Table 8 shows the vortex tubes with forced cooling. Temperature data are presented using °C units.
Table 7.
Changes temperature average air exits from the natural cooling vortex tube heat outlet.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 2.300°C | 3.075°C | 3.500°C |
| 40% | 3.550°C | 4.800°C | 5.550°C |
| 50% | 5.500°C | 8.050°C | 9.650°C |
| 60% | 7.900°C | 11.975°C | 14.000°C |
| 70% | 5.500°C | 8.750°C | 10.850°C |
Table 8.
Changes temperature of the mean air exit from the vortex tube heat outlet and forcible cooling.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 0.400°C | 0.550°C | 0.650°C |
| 40% | 1.025°C | 1.575°C | 1.975°C |
| 50% | 1.325°C | 2.050°C | 2.600°C |
| 60% | 1.575°C | 2.550°C | 3.250°C |
| 70% | 1.050°C | 1.650°C | 2.050°C |
The temperature change in the isentropic process (ΔTis) is calculated by the following equation [8]
| (3) |
Where the specific heat ratio (γ) is the specific heat at constant pressure (Cp) per specific heat at constant volume (Cv) [9]. Based on the Cengel table appendix 1 (2006) for this ambient experiment the constant pressure (Cp) is 1.007kJ/kg.K and constant volume (Cv) is 0.7180kJ/kg.K [9]:
| (4) |
Temperature change in the isentropic process (ΔTis) produced by vortex tubes with natural cooling and forced cooling tube types is presented in Table 9 shows the vortex tubes with forced cooling. Temperature data are presented using °C units.
Table 9.
Temperature change in the isentropic process of air enter into of the vortex tube inlet.
| Air pressure to inlet | ||
|---|---|---|
| 0.5bar | 1.0bar | 1.5bar |
| 32.63°C | 53.68°C | 68.88°C |
Isentropic Efficiency (ηis) is the sum of the changes in the inlet to outlet temperature at each isentropic temperature change, as shown in the following equation [8]:
| (5) |
The cold outlet isentropic efficiency (ηisc) and hot outlet isentropic efficiency (ηish) equations are shown by the following:
| (6) |
| (7) |
The Cold Isentropic Efficiency (ηisc) of cold air produced by vortex tubes with natural cooling tube types is presented in Table 10 while Table 11 shows the vortex tubes with forced cooling. An isentropic Efficiency is a dimensionless number, expressed as a percentage number.
Table 10.
Average Isentropic Efficiency of air coming out of the natural cooling vortex tube cooling outlet.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 16.39% | 16.30% | 16.19% |
| 40% | 18.08% | 17.98% | 17.53% |
| 50% | 15.63% | 15.56% | 15.43% |
| 60% | 14.25% | 14.21% | 14.08% |
| 70% | 12.79% | 12.71% | 12.56% |
Table 11.
Isentropic Efficiency mean air exits from the vortex tube cold forced cooling outlet.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 19.61% | 19.38% | 18.95% |
| 40% | 20.84% | 20.40% | 19.67% |
| 50% | 20.22% | 19.65% | 18.87% |
| 60% | 19.61% | 18.91% | 18.04% |
| 70% | 18.46% | 17.37% | 16.08% |
The Hot Isentropic Efficiency (ηish) of hot air produced by vortex tubes with natural cooling tube types is presented in Table 12 while Table 13 shows the vortex tubes with forced cooling.
Table 12.
Hot Isentropic Efficiency exits from the natural cooling vortex tube heat outlet.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 7.05% | 5.73% | 5.08% |
| 40% | 10.88% | 8.94% | 8.06% |
| 50% | 16.85% | 15.00% | 14.01% |
| 60% | 24.21% | 22.31% | 20.33% |
| 70% | 16.85% | 16.30% | 15.75% |
Table 13.
Hot Isentropic Efficiency exits from the vortex tube heat outlet and forcible cooling.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 1.23% | 1.02% | 0.94% |
| 40% | 3.14% | 2.93% | 2.87% |
| 50% | 4.06% | 3.82% | 3.77% |
| 60% | 4.83% | 4.75% | 4.72% |
| 70% | 3.22% | 3.07% | 2.98% |
The fraction (ɛc) of the cold outlet was obtained from the speed of the mass flow of air coming out, specifically at each mass flow rate of air entering the inlet . In Eq. (8), each air mass flow was measured at the same diameter and air pressure to obtain a simplified Eq. (9). In general, where is the speed of air coming out at the cold outlet on n-variable tested and is the maximum mass flow rate of air coming out of the cold outlet with the heat outlet tightly closed. This is meant to satisfy the law of mass balance, which states that the mass coming out of the system is the same as the mass entering the system. The formulas to adjust the size of the fraction are as follows [2,3]
| (8) |
| (9) |
Maximum wind speed comes out of the cold outlet for each pressure is 0.5bar (8.4), 1.0bar (11.2), and 1.5bar (14.0). The regulation of the air velocity for each fraction is carried out by playing the valve gap in the hot outlet, then presented in Table 14.
Table 14.
Air velocity exits the cold outlet.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 2.5 | 3.4 | 4.2 |
| 40% | 3.4 | 4.5 | 5.6 |
| 50% | 4.2 | 5.6 | 7.0 |
| 60% | 5.0 | 6.7 | 8.4 |
| 70% | 5.9 | 7.8 | 9.8 |
The value of the volume flow rate () for each pressure is presented in Table 15 and presented in units of .
Table 15.
The rate of volume flow to the inlet.
| Air pressure to inlet | ||
|---|---|---|
| 0.5bar | 1.0bar | 1.5bar |
| 0.137029395 | 0.252419435 | 0.420141149 |
Based on the Cengel table appendix 1 (2006) the value of gas constant (R) is 0.2870kJ/kg.K [9]. The gas density (ρ) equation is described as;
| (10) |
Ambient gas temperature, used in Kelvin units, is 300.15K. The value of ρ in the following Table 16 is presented in units of .
Table 16.
The density flow to the inlet.
| Air pressure to inlet | ||
|---|---|---|
| 0.5bar | 1.0bar | 1.5bar |
| (151.335Pa) | (201.335Pa) | (251.335Pa) |
| Gas Density | ||
| 0.137029395 | 0.252419435 | 0.420141149 |
The mass flow rate flowing at the hot outlet is denoted as. The Cp value can be determined by reading the table while T is the temperature of the air coming into through the hot outlet.
According to the equilibrium equation, the mass flow rate formula is as follows [2,10]
| (11) |
Where is the air mass flow entering, while is the air mass flow coming out through the hot outlet. From Eq. (5), these variables are proportional in the inlet vortex tube. Since the instrument can only measure air conditions atthe inlet and the cold outlet, could be determined through the use of the equation.
The value of the incoming mass flow on the vortex tube is [2]
| (12) |
The mass flow that enters the inlet () for each pressure in the Table 17 is presented in units of .
Table 17.
Mass flow to the inlet.
| Air pressure to inlet | ||
|---|---|---|
| 0.5bar | 1.0bar | 1.5bar |
| 0.137 | 0.252 | 0.420 |
Mass flow at cold outlet () that occur at the nth cold fraction is denoted by the following equation:
| (13) |
Mass flow out through the cold outlet in the Table 18 is presented in the following table in unit .
Table 18.
Mass flow exits from the cold outlet.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 0.041 | 0.076 | 0.126 |
| 40% | 0.055 | 0.101 | 0.168 |
| 50% | 0.069 | 0.126 | 0.210 |
| 60% | 0.082 | 0.151 | 0.252 |
| 70% | 0.096 | 0.177 | 0.294 |
Refer to Eq. 11, the mass flow through the hot outlet () that occur at the nth cold fraction is denoted by the following equation:
| (14) |
Mass flow out through the hot outlet is presented in the Table 19 in unit .
Table 19.
Mass flow exits from the hot outlet.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 0.096 | 0.177 | 0.294 |
| 40% | 0.082 | 0.151 | 0.252 |
| 50% | 0.069 | 0.126 | 0.210 |
| 60% | 0.055 | 0.101 | 0.168 |
| 70% | 0.041 | 0.076 | 0.126 |
The amount of heat that can be transferred by the vortex tube as a cooling effect is denoted as . It is obtained using the following equation [2,3,11,12]:
| (15) |
Where is the air mass flowing every second at the cold outlet, Cp is the capacity of air at ambient during the test, Tc is the value of the air temperature through the cold outlet, and Tin is the temperature of the air entering the inlet vortex tube. The Tc and Tin values were obtained from the data measured.
The Table 20 dan Table 21 present the heat flow rate for cold outlet in .
Table 20.
Heat flow rate at cold outlet on natural cooling RHVT.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 0.221 | 0.667 | 1.415 |
| 40% | 0.326 | 0.981 | 2.043 |
| 50% | 0.352 | 1.061 | 2.248 |
| 60% | 0.385 | 1.163 | 2.462 |
| 70% | 0.403 | 1.214 | 2.562 |
Table 21.
Heat flow rate at cold outlet on force cooling RHVT.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 0.265 | 0.793 | 1.656 |
| 40% | 0.375 | 1.113 | 2.293 |
| 50% | 0.455 | 1.341 | 2.750 |
| 60% | 0.530 | 1.548 | 3.154 |
| 70% | 0.582 | 1.659 | 3.280 |
The amount of heat transferred by the vortex tube as a heating effect is denoted by and obtained using the following equation [13]:
| (16) |
The mass flow rate flowing at the hot outlet is denoted as. The Cp value can be determined by reading the table while T is the temperature of the air coming into through the hot outlet. The Table 22 and Table 23 present the heat flow rate for hot outlet in .
Table 22.
Heat flow rate at hot outlet on natural cooling RHVT.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 0.222 | 0.547 | 1.037 |
| 40% | 0.294 | 0.732 | 1.409 |
| 50% | 0.379 | 1.023 | 2.041 |
| 60% | 0.436 | 1.218 | 2.369 |
| 70% | 0.228 | 0.667 | 1.377 |
Table 23.
Heat flow rate at hot outlet on force cooling RHVT.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 0.039 | 0.098 | 0.193 |
| 40% | 0.085 | 0.240 | 0.501 |
| 50% | 0.091 | 0.261 | 0.550 |
| 60% | 0.087 | 0.259 | 0.550 |
| 70% | 0.043 | 0.126 | 0.260 |
The total compressed air power entering the inlet with ideal isothermal compression is as follows [3,6,7,[13], [14], [15]:
| (17) |
From Eq. (17), is the mass flow rate of air entering the inlet channel, R is the specific gas constant, Tin is the temperature of the air, and Pin is the air pressure entering the inlet channel. The environmental air pressure is denoted by Patm. The Table 24 presents the total compressed air power entering the inlet in .
Table 24.
Total compressed air power entering the inlet.
| Air pressure to inlet | ||
|---|---|---|
| 0.5bar | 1.0bar | 1.5bar |
| 4.734 | 14.928 | 32.875 |
The coefficient of performance refrigeration (COPref) is a dimensionless number that measures the performance of a cooling heat pump engine when transferring heat from a cooled room [2,12]. For a vortex tube, it is calculated as follows [2,3,12].
| (18) |
The average COPref produced by vortex tube with natural cooling tube type is presented in Table 25 while the vortex tube with forced cooling is shown in Table 26. COPref numbers are dimensionless, therefore they are presented without units.
Table 25.
COPref average air exits from the natural vortex tube cold cooling outlet.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 0.047 | 0.046 | 0.044 |
| 40% | 0.069 | 0.068 | 0.062 |
| 50% | 0.074 | 0.074 | 0.070 |
| 60% | 0.081 | 0.081 | 0.079 |
| 70% | 0.085 | 0.083 | 0.083 |
Table 26.
COPref the mean air coming out of the vortex cold tube forced cooling outlet.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 0.056 | 0.054 | 0.050 |
| 40% | 0.079 | 0.078 | 0.069 |
| 50% | 0.096 | 0.093 | 0.087 |
| 60% | 0.112 | 0.104 | 0.097 |
| 70% | 0.123 | 0.111 | 0.100 |
The coefficient of performance heat pumps (COPh) is a dimensionless number that measures the performance of a heat pump engine when transferring heat to a heated chamber [2,12]. It was denoted as follows in the vortex tube [2,3,12].
| (19) |
Table 27 and 28 shows the average COPh produced by vortex tubes with natural cooling tube types and vortex tubes with forced cooling respectively. There are no dimensions for COPh numbers.
Table 29.
Experimental devices.
| Initial | Name | Function | Symbol | Unit | Sensitivity values |
|---|---|---|---|---|---|
| AC | Air Conditioner | Room temperature controller | - | °Celsius | 0.1 |
| C | Compressor | Pressurized air supply | - | - | - |
| AT | Air Tank | Maintained air pressure so as not to drop, reduce humidity and return to room temperature | - | - | - |
| PR | Pressure Regulator | Sets the input air pressure | - | - | - |
| PG | Pressure Gauge | Measured inlet air pressure | Pin | bar | 0.1 |
| AFM | Flowmeter (air) | Measured airflow | Liter/min | 0.1 | |
| VTA / VTB | Vortex tube (type A and type B) | Test instrument | - | - | - |
| AM | Anemometer | Measured the speed of cold outlet air | and | meter/sec | 0.1 |
| TCD | Thermocouple Display | Measured hot and cold outlet air temperature | °Celsius | 0.01 | |
| WCS | Water Container Storage | Saved water for cooling | - | - | - |
| WCT | Water Container Trash | Saved waste water for cooling | - | - | - |
| P | Pump | Pumped cooling water | - | - | - |
| WFM | Flowmeter (water) | Measured water discharge | Liter/min | 0.1 | |
| DA | Data Acquisition | Recorded measurement data | - | - | - |
| PC | Personal Computer | Processed observation data from each measuring instrument | - | - | - |
| TCS1 | Thermocouple Sensor 1 (Type K) | Measured the temperature of the inlet air | Tin | °Celsius | - |
| TCS2 | Thermocouple Sensor 2 (Type K) | Measured the temperature of the cold outlet air | Tc | °Celsius | - |
| TCS3 | Thermocouple Sensor 3 (Type K) | Measured the temperature of the hot outlet air | Th | °Celsius | - |
| TCS4 | Thermocouple Sensor 4 (Type K) | Measured ambient air temperature | T | °Celsius | - |
| TCS5 | Thermocouple Sensor 5 (Type K) | Measured the temperature of the cooling water air | - | °Celsius | - |
Table 27.
COPh mean air exit from the vortex tube and cold forced outlet.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 0.047 | 0.037 | 0.036 |
| 40% | 0.066 | 0.049 | 0.043 |
| 50% | 0.080 | 0.068 | 0.062 |
| 60% | 0.076 | 0.081 | 0.072 |
| 70% | 0.039 | 0.043 | 0.042 |
Table 28.
COPh average air exits from the vortex tube cold forced outlet.
| Cold air mass fraction | Air pressure to inlet |
||
|---|---|---|---|
| 0.5bar | 1.0bar | 1.5bar | |
| 30% | 0.008 | 0.007 | 0.006 |
| 40% | 0.018 | 0.016 | 0.015 |
| 50% | 0.019 | 0.017 | 0.017 |
| 60% | 0.018 | 0.017 | 0.017 |
| 70% | 0.009 | 0.008 | 0.008 |
2. Experimental Design, Materials, and Methods
Data collection was carried out through experimental tests and processed mathematically. The RHVTs include types A with a natural cooling process and B with the forced cooling process, both on the surfaces of the tube. The RHVT used in types A and B was counter flow and the material used in all case was aluminium, except the cooling tube of B which used the black Teflon. The inlet diameter was 5mm, while the cold and hot tube had diameters and lengths 5mm and 40mm as well as 8mm and 105mm respectively. The diameter of the inlet and outlet of the cooling tube on type B RHVT was 8mm. However, an inner tube had a diameter of 25mm and a length of 75mm. Fig. 1 shows the details of the RHVT specifications used.
Figure 1.
Two types of vortex tubes, A and B.
Types A and B had 4 nozzle holes and the air rotation is in the direction of the flow at the inlet. The nozzle hole is rectangular with dimensions of 1 × 2mm. The diameter of the round nozzles is 8mm with a thickness of 1.5mm. The detailed specifications of the RHVT contra flow nozzles used are presented in Fig. 2.
Figure 2.
RHVT contra flow nozzles specifications.
Fig. 3 shows a series of instruments used for experimental data collection. In the Left and right sides of the figure are Type A and B vortex tubes respectively. The temperature was set at 27o±0.1°C and data were recorded after 5 minutes of running.
Figure 3.
Series of experimental tools for types A and B.
Acknowledgments
Acknowledgments
This research is partially funded by the Indonesian Ministry of Research, Technology and Higher Education under WCU Program managed by Institut Teknologi Bandung.
Conflict of Interest
The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Footnotes
Supplementary material associated with this article can be found, in the online version, at doi:10.1016/j.dib.2020.105611.
Contributor Information
Alfan Sarifudin, Email: alfansarifudin.indonesia@gmail.com, alfansarifudin@merahputih.id.
Nugroho Agung Pambudi, Email: agung.pambudi@staff.uns.ac.id.
Appendix. Supplementary materials
References
- 1.Aydin O., Markal B., Avci M. A new vortex generator geometry for a counter-flow Ranque-Hilsch vortex tube. Appl. Therm. Eng. 2010;30(16):2505–2511. [Google Scholar]
- 2.Sarifudin A., Wijayanto D.S., Widiastuti I. Parameters optimization of tube type, pressure, and mass fraction on vortex tube performance using the Taguchi method. Int. J. Heat Technol. 2019;37(2):597–604. [Google Scholar]
- 3.Attalla M., Ahmed H., Ahmed M.S., El-Wafa A.A. Experimental investigation for thermal performance of series and parallel Ranque-Hilsch vortex tube systems. Appl. Therm. Eng. 2017;123:327–339. [Google Scholar]
- 4.Alekhin V., Bianco V., Khait A., Noskov A. Numerical investigation of a double-circuit Ranque-Hilsch vortex tube. Int. J. Therm. Sci. 2015;89:272–282. [Google Scholar]
- 5.Kirmaci V., Kaya H. Effects of working fluid, nozzle number, nozzle material and connection type on thermal performance of a Ranque–Hilsch vortex tube: A review. Int. J. Refrig. 2018;91:254–266. [Google Scholar]
- 6.Attalla M., Ahmed H., Salem Ahmed M., Abo El- Wafa A. An experimental study of nozzle number on Ranque Hilsch counter-flow vortex tube. Exp. Therm. Fluid Sci. 2017;82:381–389. [Google Scholar]
- 7.Kumar A., Vivekanand, Subudhi S. Cooling and dehumidification using vortex tube. Appl. Therm. Eng. 2017;122:181–193. [Google Scholar]
- 8.Eiamsa-ard S., Wongcharee K., Promvonge P. Experimental investigation on energy separation in a counter-flow Ranque-Hilsch vortex tube: Effect of cooling a hot tube. Int. Commun. Heat Mass Transf. 2010;37(2):156–162. [Google Scholar]
- 9.Yunus M.A.B., Çengel A. 5th ed. McGraw-Hill; New York: 2006. Thermodynamics: An Engineering Approach. [Google Scholar]
- 10.Hamdan M.O., Al-Omari S.A.B., Oweimer A.S. Experimental study of vortex tube energy separation under different tube design. Exp. Therm. Fluid Sci. August 2017;91:306–311. 2018. [Google Scholar]
- 11.Rafiee S.E., Sadeghiazad M.M. Heat and mass transfer between cold and hot vortex cores inside Ranque-Hilsch vortex tube-optimization of hot tube length. Int. J. Heat Technol. 2016;34(1):31–38. [Google Scholar]
- 12.Y. A.. Cengel and J. M.. Cimbala, Fluid Mechanics: Fundamentals and Applications. 2014.
- 13.R. Simo, “An air-standard cycle and a thermodynamic perspective on operational limits of Ranque – Hilsh or vortex tubes ` air traditionnel, aspects thermodynamiques et limites Cycle a du fonctionnement des tubes Ranque-Hilsch ou vortex,” vol. 33, pp. 765–773, 2010.
- 14.Devade K.D., Pise A.T. Effect of Mach number, valve angle and length to diameter ratio on thermal performance in flow of air through Ranque Hilsch vortex tube. Heat Mass Transf. und Stoffuebertragung. 2017;53(1):161–168. [Google Scholar]
- 15.Subudhi S., Sen M. Review of Ranque-Hilsch vortex tube experiments using air. Renew. Sustain. Energy Rev. 2015;52:172–178. [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.