. 2020 May 15;105(4):784–786. doi: 10.1016/j.jhin.2020.05.017

Detection of SARS-CoV-2 on high-touch surfaces in a clinical microbiology laboratory

I Bloise 1,, B Gómez-Arroyo 1, J García-Rodríguez 1; SARS-CoV-2 Working Group1,
PMCID: PMC7227510  PMID: 32422312

Sir,

Severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) is a new human betacoronavirus responsible for coronavirus disease 2019 (COVID-19), which is an ongoing pandemic worldwide. This pandemic outbreak has resulted in a massive demand for healthcare services. Healthcare workers (HCWs) are one of the most affected groups, accounting for 10% of all confirmed cases. Infected HCWs with symptoms and, particularly, those who are asymptomatic represent a high risk for hospital-acquired COVID-19 [1,2]. It is well known that the virus is mainly transmitted through droplets when an infected person sneezes, coughs or talks. These droplets land on the floor or other surfaces where the virus may survive for some time and constitute a major source of infection.

Our aim was to evaluate the presence of viral RNA in fomites in our microbiology laboratory, particularly in the area used for SARS-CoV-2 diagnosis during this pandemic outbreak. We sampled 22 locations inside the laboratory, selecting surfaces subject to frequent contact (high-touch surfaces). Details about sampling features are given in Table I . World Health Organization guidelines were followed for collection of samples [3]. NucliSENS EasyMAG (bioMérieux, Marcy l’Etoile, France) was used for nucleic acid extraction. TaqMan 2019-nCoV Assay Kit v1 (Thermo Fisher Scientific Inc., Franklin, MA, USA) was used for detection of viral RNA. This kit targets ORF1ab, gene N and gene S, and uses human RNase P as the internal control. In addition, an environmental control sample and a positive control sample were included. The environmental control sample was SARS-CoV-2 and RNase P negative. Within the 22 samples, four were positive (one sample for two genes and three samples for one gene). RNase P was detected in all samples (Table I).

Table I.

Samples collected and results

Sample number Sample type Location ORF1ab gene (Ct) IC: Ct Gene S (Ct) IC: Ct Gene N (Ct) IC: Ct
1 Landline COVID-19 diagnostic box NA
IC: 35.14
NA
IC: 36.46
NA
IC: 35.97
2 Barcode scanner COVID-19 diagnostic box NA
IC: 38.04
NA
IC: NA
NA
IC: 38.02
3 Blood culture box NA
IC: NA
NA
IC: 38.49
NA
IC: 36.93
4 Respiratory culture box NA
IC: 39.25
NA
IC: 39.78
NA
IC: 38.05
5 COVID-19 thermocycler NA
IC: 35.35
NA
IC: 34.30
NA
IC: 34.79
6 Mobile phone Laboratory NA
IC: NA
NA
IC: 35.96
A (38.80)
IC: 36.07
7 NA
IC: 34.86
NA
IC: 35.01
NA
IC: 34.14
8 Personal NA
IC: 35.46
NA
IC: 34.60
NA
IC: 35.00
9 NA
IC: 33.29
NA
IC: 33.82
NA
IC: 33.75
10 NA
IC: 34.45
NA
IC: 34.00
NA
IC: 34.48
11 NA
IC: 34.89
NA
IC: 35.51
NA
IC: 34.23
12 NA
IC: NA
NA
IC: NA
NA
IC: 35.88
13 NA
IC: 32.09
NA
IC: 36.38
NA
IC: 36.25
14 NA
IC: 31.49
NA
IC: 30.97
NA
IC: 31.25
15 Mouse COVID-19 diagnostic box A (38.98)
IC: 34.49
NA
IC: 34.82
A (37.55)
IC: 34.23
16 Blood culture box NA
IC: 34.56
NA
IC: 34.44
NA
IC: 34.65
17 Respiratory culture box NA
IC: 36.17
NA
IC: 38.10
NA
IC: 36.71
18 COVID-19 thermocycler NA
IC: 34.27
NA
IC: 34.98
A (38.33)
IC: 35.31
19 Keyboard COVID-19 diagnostic box NA
IC: 34.92
NA
IC: 36.89
NA
IC: 35.00
20 Blood culture box NA
IC: 32.62
NA
IC: NA
NA
IC: 31.85
21 Respiratory culture box NA
IC: 32.54
NA
IC: 32.51
NA
IC: 32.87
22 COVID-19 thermocycler NA
IC: 30.43
NA
IC: 29.82
A (30.32)
IC: 30.39
23 Environmental COVID-19 diagnostic box NA
IC: NA
NA
IC: NA
NA
IC: NA

A, amplified; NA, not amplified; IC, internal control; Ct, cycle threshold.

Our data confirm the presence of SARS-CoV-2 on fomites and suggest that environmental contamination might play a role in its transmission among HCWs. In this study, samples were obtained from working areas that are not accessed by patients, but where a high density of respiratory samples were tested for diagnosis of COVID-19. Despite this, the environmental control sample was negative. Samples obtained from personal objects were negative, suggesting that measures in place to avoid transmission (minimum safety distance, handwashing and surface decontamination) are effective. We detected viral RNA on the surfaces of commonly used objects, such as keyboards, telephones and scanners, and they could represent sources of infection for laboratory personnel [4,5].

Human RNaseP RNA was detected on most high-touch surfaces, and the RNaseP threshold cycles (Ct) tended to be higher than those of respiratory samples. This must be taken into account in the interpretation of viral target results, as they could also be higher. Amplification of all three targets (ORF1ab, gene N and gene S) was not achieved in any sample. In one sample, two targets were amplified but in high Ct. Another sample amplified one target in an early cycle (Ct: 30). The two remaining samples had late amplifications.

The design of this study includes some limitations that may lead to bias. As we based our detection on quantitative reverse transcriptase polymerase chain reaction, it was not possible to differentiate between infectious and non-infectious virus present on fomites. It is important to highlight that three of the four surfaces that tested positive were inside the COVID-19 diagnostic area, and the fourth surface was the laboratory mobile phone used by the microbiologist on call. In that context, we have to consider the possibility of cross-contamination with extracted RNA or amplified DNA.

These findings highlight the need for frequent disinfection of shared objects for the safety of all HCWs. It has been reported that ethanol 61–72% and sodium hyplochlorite 0.5% are effective against other coronaviruses, and this is also expected for SARS-CoV-2 [6].

Conflict of interest statement

None declared.

Funding sources

None.

Acknowledgments

The authors wish to thank Dr. Jesús Mingorance for his comments and suggestions that really improved the manuscript.

References

  • 1.Ji Y., Ma Z., Peppelenbosch M.P., Pan Q. Potential association between COVID-19 mortality and health-care resource availability. Lancet Glob Health. 2020;8 doi: 10.1016/S2214-109X(20)30068-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.European Centre for Disease Prevention and Control . ECDC; Stockholm: 2020. Novel coronavirus disease 2019 (COVID-19) pandemic: increased transmission in the EU/EEA and the UK – sixth update. [Google Scholar]
  • 3.World Health Organization . WHO; Geneva: 2020. Surface sampling of coronavirus disease (COVID-19): a practical “how to” protocol for health care and public health professionals. [Google Scholar]
  • 4.Ye G., Lin H., Chen L., Wang S., Zeng Z., Wang W. Environmental contamination of the SARS-CoV-2 in healthcare premises: an urgent call for protection for healthcare workers. medRxiv. 2020 doi: 10.1101/2020.03.11.20034546. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Otter J.A., Donskey C., Yezli S., Douthwaite S., Goldenberg S.D., Weber D.J. Transmission of SARS and MERS coronaviruses and influenza virus in healthcare settings: the possible role of dry surface contamination. J Hosp Infect. 2016;92:235–250. doi: 10.1016/j.jhin.2015.08.027. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Kampf G., Todt D., Pfaender S., Steinmann E. Persistence of coronaviruses on inanimate surfaces and their inactivation with biocidal agents. J Hosp Infect. 2020;104:246–251. doi: 10.1016/j.jhin.2020.01.022. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from The Journal of Hospital Infection are provided here courtesy of Elsevier

RESOURCES